2025-10-24T04:49:46.558Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-24T04:53:53.472Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T04:59:15.539Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-24T04:59:45.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-24T05:00:53.031Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-24T05:00:53.039Z:INFO:db_chargingprofi:26: socket 0
2025-10-24T05:00:53.046Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-24T05:00:53.054Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-24T05:00:53.062Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-24T05:00:53.070Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-24T05:00:53.082Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-24T05:00:53.089Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-24T05:00:53.101Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-24T05:00:53.109Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-24T05:00:53.117Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-24T05:00:53.125Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-24T05:00:53.132Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-24T05:00:53.140Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-24T05:00:53.148Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-24T05:00:53.156Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-24T05:00:53.164Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-24T05:00:53.175Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-24T05:00:53.183Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-24T05:00:53.191Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-24T05:00:53.199Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-24T05:00:53.207Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-24T05:00:53.214Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-24T05:03:53.406Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T05:04:46.453Z:USER:taskMaster.c:6599:Socket #1: L1N=233.7V L2N=234.0V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T05:04:46.464Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-24T05:13:53.343Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T05:14:15.839Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-24T05:14:45.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-24T05:19:46.355Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=235.5V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T05:19:46.367Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-24T05:23:53.281Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T05:29:16.296Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-24T05:29:45.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-24T05:33:53.214Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T05:34:46.261Z:USER:taskMaster.c:6599:Socket #1: L1N=234.0V L2N=234.8V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T05:34:46.273Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-24T05:43:53.152Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T05:44:16.648Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-24T05:44:45.046Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-24T05:49:46.164Z:USER:taskMaster.c:6599:Socket #1: L1N=233.7V L2N=234.9V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T05:49:46.175Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-24T05:50:12.773Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-10-24T05:53:53.089Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T05:59:17.054Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-24T05:59:45.000Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-24T06:00:12.808Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-10-24T06:01:00.546Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-24T06:01:00.554Z:INFO:db_chargingprofi:26: socket 0
2025-10-24T06:01:00.562Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-24T06:01:00.570Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-24T06:01:00.578Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-24T06:01:00.589Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-24T06:01:00.601Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-24T06:01:00.609Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-24T06:01:00.617Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-24T06:01:00.625Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-24T06:01:00.632Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-24T06:01:00.640Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-24T06:01:00.652Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-24T06:01:00.675Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-24T06:01:00.683Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-24T06:01:00.695Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-24T06:01:00.703Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-24T06:01:00.710Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-24T06:01:00.722Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-24T06:01:00.730Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-24T06:01:00.738Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-24T06:01:00.746Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-24T06:01:00.753Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-24T06:03:53.023Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T06:04:46.070Z:USER:taskMaster.c:6599:Socket #1: L1N=234.3V L2N=235.3V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T06:04:46.082Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-24T06:10:12.843Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-10-24T06:13:52.960Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T06:14:17.410Z:USER:taskMaster.c:6497:Temperature: 22.5 C
2025-10-24T06:14:45.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-24T06:19:46.023Z:USER:taskMaster.c:6599:Socket #1: L1N=235.3V L2N=235.6V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T06:19:46.035Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-24T06:23:52.898Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T06:29:17.761Z:USER:taskMaster.c:6497:Temperature: 22.5 C
2025-10-24T06:29:45.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-24T06:33:52.832Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T06:34:45.925Z:USER:taskMaster.c:6599:Socket #1: L1N=234.8V L2N=234.7V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T06:34:45.941Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-24T06:43:44.449Z:INFO:heap_trace.c:493:free: 61856/160768 (38.5%) min: 35456 (22.1%) alloc #: 211
2025-10-24T06:43:44.460Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 20 largest: 41080
2025-10-24T06:43:52.769Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T06:44:18.167Z:USER:taskMaster.c:6497:Temperature: 22.6 C
2025-10-24T06:44:45.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-24T06:49:45.832Z:USER:taskMaster.c:6599:Socket #1: L1N=233.2V L2N=232.6V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T06:49:45.843Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-24T06:53:52.707Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T06:59:18.570Z:USER:taskMaster.c:6497:Temperature: 22.5 C
2025-10-24T06:59:45.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-24T07:01:08.011Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-24T07:01:08.023Z:INFO:db_chargingprofi:26: socket 0
2025-10-24T07:01:08.031Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-24T07:01:08.039Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-24T07:01:08.046Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-24T07:01:08.054Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-24T07:01:08.066Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-24T07:01:08.078Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-24T07:01:08.085Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-24T07:01:08.093Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-24T07:01:08.101Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-24T07:01:08.109Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-24T07:01:08.121Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-24T07:01:08.128Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-24T07:01:08.132Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-24T07:01:08.144Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-24T07:01:08.152Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-24T07:01:08.160Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-24T07:01:08.171Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-24T07:01:08.179Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-24T07:01:08.187Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-24T07:01:08.195Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-24T07:01:08.203Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-24T07:03:52.640Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T07:04:45.734Z:USER:taskMaster.c:6599:Socket #1: L1N=234.6V L2N=234.6V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T07:04:45.750Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-24T07:13:52.578Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.0 24.0 23.2)A
2025-10-24T07:14:18.824Z:USER:taskMaster.c:6497:Temperature: 22.8 C
2025-10-24T07:14:45.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-24T07:19:45.640Z:USER:taskMaster.c:6599:Socket #1: L1N=235.0V L2N=235.2V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T07:19:45.652Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-24T07:23:52.515Z:INFO:active_lb.c:308:SMt:(1.0 6.0 1.0)A Free:(24.0 19.0 24.0)A ALB:(24.0 19.4 23.6)A
2025-10-24T07:29:19.230Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-24T07:29:45.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-24T07:33:52.449Z:INFO:active_lb.c:308:SMt:(1.0 7.0 1.0)A Free:(24.0 18.0 24.0)A ALB:(23.7 18.0 24.0)A
2025-10-24T07:34:45.546Z:USER:taskMaster.c:6599:Socket #1: L1N=237.4V L2N=236.9V L3N=237.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T07:34:45.558Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-24T07:43:52.386Z:INFO:active_lb.c:308:SMt:(1.0 6.0 1.0)A Free:(24.0 19.0 24.0)A ALB:(24.0 19.0 24.0)A
2025-10-24T07:44:19.585Z:USER:taskMaster.c:6497:Temperature: 23.2 C
2025-10-24T07:44:45.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-24T07:49:45.449Z:USER:taskMaster.c:6599:Socket #1: L1N=234.6V L2N=234.1V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T07:49:45.460Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-24T07:53:43.871Z:WARNING:taskMain.c:4908:Socket #1: EV disconnected while charging (11.7V)
2025-10-24T07:53:43.921Z:INFO:taskMain.c:6230:Socket #1: Active current 15.9->0.0 due to current limit: Cable
2025-10-24T07:53:43.933Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_WAIT_FOR_EV_RECONNECT
2025-10-24T07:53:43.945Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_A
2025-10-24T07:53:44.523Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_TERMINATING
2025-10-24T07:53:44.535Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_E
2025-10-24T07:53:44.542Z:INFO:taskMaster.c:4897:Socket #1: state led : WAIT_FOR_VEHICLE
2025-10-24T07:53:44.550Z:COM:ocpp_rpc.c:715:-> [2,"22","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-24T07:53:44.550Z:COM:ocpp_rpc.c:715:"Finishing"}]
2025-10-24T07:53:44.625Z:COM:ocpp_rpc.c:1292:<- [3,"22",{}]
2025-10-24T07:53:44.730Z:INFO:taskMain.c:6730:Socket #1: CPhigh 0.0 V
2025-10-24T07:53:44.738Z:INFO:taskMain.c:6735:Socket #1: CPlow 0.0 V
2025-10-24T07:53:44.746Z:INFO:taskMain.c:6740:Socket #1: PP 34464 Ohm (0 A)
2025-10-24T07:53:45.628Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_TERMINATING, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-10-24T07:53:48.523Z:INFO:taskMaster.c:4875:Socket #1: state main : WAIT_FOR_STOP_METERVALUE
2025-10-24T07:53:49.519Z:INFO:taskMain.c:943:Socket #1: charging session status set inactive
2025-10-24T07:53:49.531Z:INFO:taskMaster.c:4875:Socket #1: state main : WAIT_FOR_DISCONNECT
2025-10-24T07:53:49.539Z:USER:board_ng9xx.c:5059:Socket #1: unlock socket motor
2025-10-24T07:53:50.648Z:INFO:board_ng9xx.c:5628:Socket 1: emergency relays check OK
2025-10-24T07:53:51.898Z:INFO:db_transaction.c:16:Added TransactionStop for socket 1 at 0x000b7a77 (ts: 2025-10-24 07:53:49)
2025-10-24T07:53:51.910Z:INFO:db_transaction.c:16:Updated TransactionStart for socket 1 at 0x000b7637 (ts: 2025-10-23 20:44:44)
2025-10-24T07:53:51.972Z:INFO:taskMaster.c:4897:Socket #1: state led : AVAILABLE
2025-10-24T07:53:51.980Z:COM:ocpp_rpc.c:715:-> [2,"23","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-24T07:53:51.980Z:COM:ocpp_rpc.c:715:"Available"}]
2025-10-24T07:53:52.000Z:INFO:taskMaster.c:4875:Socket #1: state main : AVAILABLE
2025-10-24T07:53:52.019Z:INFO:taskMain.c:6676:Socket #1: active tag cleared
2025-10-24T07:53:52.027Z:COM:ocpp_rpc.c:1292:<- [3,"23",{}]
2025-10-24T07:53:52.324Z:INFO:active_lb.c:308:SMt:(-1.0 6.0 1.0)A Free:(26.0 19.0 24.0)A ALB:(25.3 19.0 24.0)A
2025-10-24T07:53:52.960Z:INFO:taskMain.c:1426:Socket #1: main state: AVAILABLE, CP: 0.0/0.0, no tag
2025-10-24T07:59:19.988Z:USER:taskMaster.c:6497:Temperature: 23.2 C
2025-10-24T08:03:52.257Z:INFO:active_lb.c:308:SMt:(4.0 1.0 1.0)A Free:(21.0 24.0 24.0)A ALB:(18.9 24.0 24.0)A
2025-10-24T08:04:45.355Z:USER:taskMaster.c:6599:Socket #1: L1N=233.8V L2N=233.6V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T08:13:52.195Z:INFO:active_lb.c:308:SMt:(-2.0 1.0 1.0)A Free:(27.0 24.0 24.0)A ALB:(24.6 24.0 24.0)A
2025-10-24T08:14:20.394Z:USER:taskMaster.c:6497:Temperature: 23.2 C
2025-10-24T08:19:45.257Z:USER:taskMaster.c:6599:Socket #1: L1N=238.1V L2N=237.9V L3N=238.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T08:23:52.132Z:INFO:active_lb.c:308:SMt:(-2.0 1.0 1.0)A Free:(27.0 24.0 24.0)A ALB:(27.0 24.9 24.0)A
2025-10-24T08:29:20.746Z:USER:taskMaster.c:6497:Temperature: 23.9 C
2025-10-24T08:33:52.070Z:INFO:active_lb.c:308:SMt:(-2.0 1.0 1.0)A Free:(27.0 24.0 24.0)A ALB:(27.0 24.0 24.0)A
2025-10-24T08:34:45.164Z:USER:taskMaster.c:6599:Socket #1: L1N=232.1V L2N=232.0V L3N=231.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T08:43:34.050Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-24T08:43:34.320Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-24T08:43:43.687Z:INFO:heap_trace.c:493:free: 61856/160768 (38.5%) min: 35456 (22.1%) alloc #: 211
2025-10-24T08:43:43.699Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 20 largest: 41080
2025-10-24T08:43:52.003Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.1 24.0 23.0)A
2025-10-24T08:43:52.156Z:INFO:comFaults.c:482:Reset fault status
2025-10-24T08:43:53.738Z:COM:ocpp_rpc.c:715:-> [2,"24","Heartbeat",{}]
2025-10-24T08:43:53.781Z:COM:ocpp_rpc.c:1292:<- [3,"24",{"currentTime":"2025-10-24T08:44:00.084Z"}]
2025-10-24T08:44:00.000Z:SECURITY:taskTime.c:603:Time changed
2025-10-24T08:44:27.359Z:USER:taskMaster.c:6497:Temperature: 23.8 C
2025-10-24T08:49:51.273Z:USER:taskMaster.c:6599:Socket #1: L1N=235.2V L2N=236.2V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T08:53:58.148Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 22.9)A
2025-10-24T08:59:27.714Z:USER:taskMaster.c:6497:Temperature: 23.8 C
2025-10-24T09:03:58.085Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 26.0 23.8)A
2025-10-24T09:04:51.179Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=234.1V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T09:13:58.023Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(26.0 24.3 22.8)A
2025-10-24T09:14:28.121Z:USER:taskMaster.c:6497:Temperature: 24.0 C
2025-10-24T09:19:51.085Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=234.3V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T09:23:57.957Z:INFO:active_lb.c:308:SMt:(-1.0 5.0 2.0)A Free:(26.0 20.0 23.0)A ALB:(26.0 20.1 23.0)A
2025-10-24T09:29:28.523Z:USER:taskMaster.c:6497:Temperature: 24.0 C
2025-10-24T09:33:57.894Z:INFO:active_lb.c:308:SMt:(1.0 5.0 2.0)A Free:(24.0 20.0 23.0)A ALB:(24.7 20.1 23.0)A
2025-10-24T09:34:50.988Z:USER:taskMaster.c:6599:Socket #1: L1N=234.9V L2N=234.6V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T09:43:57.832Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(26.0 24.0 23.0)A
2025-10-24T09:44:28.878Z:USER:taskMaster.c:6497:Temperature: 24.2 C
2025-10-24T09:49:50.894Z:USER:taskMaster.c:6599:Socket #1: L1N=235.3V L2N=236.0V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T09:53:57.769Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 2.0)A Free:(26.0 26.0 23.0)A ALB:(26.0 26.1 23.0)A
2025-10-24T09:59:29.285Z:USER:taskMaster.c:6497:Temperature: 24.2 C
2025-10-24T10:03:57.703Z:INFO:active_lb.c:308:SMt:(-1.0 -4.0 2.0)A Free:(26.0 29.0 23.0)A ALB:(24.0 27.9 23.0)A
2025-10-24T10:04:50.800Z:USER:taskMaster.c:6599:Socket #1: L1N=235.3V L2N=235.1V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T10:13:57.640Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(26.2 25.3 23.0)A
2025-10-24T10:14:29.636Z:USER:taskMaster.c:6497:Temperature: 24.1 C
2025-10-24T10:19:50.703Z:USER:taskMaster.c:6599:Socket #1: L1N=235.8V L2N=236.0V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T10:23:57.578Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 2.0)A Free:(26.0 26.0 23.0)A ALB:(26.1 26.5 23.0)A
2025-10-24T10:29:30.042Z:USER:taskMaster.c:6497:Temperature: 24.2 C
2025-10-24T10:33:57.562Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(24.0 24.0 22.7)A
2025-10-24T10:34:50.609Z:USER:taskMaster.c:6599:Socket #1: L1N=232.1V L2N=232.0V L3N=230.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T10:43:49.132Z:INFO:heap_trace.c:493:free: 61856/160768 (38.5%) min: 35456 (22.1%) alloc #: 211
2025-10-24T10:43:49.144Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 20 largest: 41080
2025-10-24T10:43:57.500Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(25.1 24.1 22.3)A
2025-10-24T10:44:30.398Z:USER:taskMaster.c:6497:Temperature: 24.0 C
2025-10-24T10:49:50.511Z:USER:taskMaster.c:6599:Socket #1: L1N=231.6V L2N=232.6V L3N=231.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T10:53:57.437Z:INFO:active_lb.c:308:SMt:(1.0 1.0 4.0)A Free:(24.0 24.0 21.0)A ALB:(24.0 23.2 23.0)A
2025-10-24T10:59:30.703Z:USER:taskMaster.c:6497:Temperature: 24.0 C
2025-10-24T11:03:57.375Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 2.0)A Free:(26.0 23.0 23.0)A ALB:(25.6 23.5 21.7)A
2025-10-24T11:04:33.253Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-24T11:04:33.609Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-24T11:04:33.898Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-24T11:04:34.070Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-10-24T11:04:34.437Z:SECURITY:web_functionalit:68:Changed '2059_00' from 1761303878269 => 1761303874916
2025-10-24T11:04:40.597Z:WARNING:taskWebClient.c:234:Client (fd=2) disconnected (r: -0x50)
2025-10-24T11:04:40.605Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-24T11:04:40.710Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-24T11:04:49.964Z:USER:taskMaster.c:6599:Socket #1: L1N=233.9V L2N=234.7V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T11:13:56.859Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(25.7 23.6 23.0)A
2025-10-24T11:14:30.656Z:USER:taskMaster.c:6497:Temperature: 23.5 C
2025-10-24T11:19:49.871Z:USER:taskMaster.c:6599:Socket #1: L1N=233.8V L2N=234.4V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T11:23:56.796Z:INFO:active_lb.c:308:SMt:(-2.0 -4.0 2.0)A Free:(27.0 29.0 23.0)A ALB:(26.6 26.6 23.0)A
2025-10-24T11:29:31.011Z:USER:taskMaster.c:6497:Temperature: 23.6 C
2025-10-24T11:33:56.730Z:INFO:active_lb.c:308:SMt:(-2.0 -3.0 6.0)A Free:(27.0 28.0 19.0)A ALB:(26.8 27.3 19.0)A
2025-10-24T11:34:49.777Z:USER:taskMaster.c:6599:Socket #1: L1N=236.2V L2N=236.7V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T11:43:56.667Z:INFO:active_lb.c:308:SMt:(-3.0 2.0 2.0)A Free:(28.0 23.0 23.0)A ALB:(27.8 22.8 23.0)A
2025-10-24T11:44:31.414Z:USER:taskMaster.c:6497:Temperature: 23.8 C
2025-10-24T11:49:49.679Z:USER:taskMaster.c:6599:Socket #1: L1N=236.9V L2N=237.5V L3N=237.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T11:53:56.605Z:INFO:active_lb.c:308:SMt:(-3.0 2.0 2.0)A Free:(28.0 23.0 23.0)A ALB:(27.2 18.4 23.0)A
2025-10-24T11:59:31.820Z:USER:taskMaster.c:6497:Temperature: 24.2 C
2025-10-24T12:03:56.542Z:INFO:active_lb.c:308:SMt:(2.0 1.0 5.0)A Free:(23.0 24.0 20.0)A ALB:(23.1 24.0 23.0)A
2025-10-24T12:04:49.585Z:USER:taskMaster.c:6599:Socket #1: L1N=235.2V L2N=235.9V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T12:13:56.476Z:INFO:active_lb.c:308:SMt:(-3.0 -4.0 2.0)A Free:(28.0 29.0 23.0)A ALB:(27.1 27.2 23.0)A
2025-10-24T12:14:32.175Z:USER:taskMaster.c:6497:Temperature: 24.5 C
2025-10-24T12:19:49.492Z:USER:taskMaster.c:6599:Socket #1: L1N=237.2V L2N=238.3V L3N=237.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T12:23:56.414Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(26.0 24.2 23.0)A
2025-10-24T12:29:32.578Z:USER:taskMaster.c:6497:Temperature: 24.8 C
2025-10-24T12:33:56.351Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(26.0 24.0 23.0)A
2025-10-24T12:34:49.394Z:USER:taskMaster.c:6599:Socket #1: L1N=235.7V L2N=235.4V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T12:43:37.972Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-24T12:43:38.242Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-24T12:43:47.917Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-24T12:43:47.929Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-24T12:43:56.289Z:INFO:active_lb.c:308:SMt:(-3.0 -3.0 2.0)A Free:(28.0 28.0 23.0)A ALB:(27.5 27.1 23.0)A
2025-10-24T12:44:32.933Z:USER:taskMaster.c:6497:Temperature: 24.5 C
2025-10-24T12:49:49.300Z:USER:taskMaster.c:6599:Socket #1: L1N=238.2V L2N=239.1V L3N=237.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T12:53:56.222Z:INFO:active_lb.c:308:SMt:(-2.0 -3.0 2.0)A Free:(27.0 28.0 23.0)A ALB:(26.9 27.4 23.0)A
2025-10-24T12:59:33.339Z:USER:taskMaster.c:6497:Temperature: 24.2 C
2025-10-24T13:03:56.160Z:INFO:active_lb.c:308:SMt:(-1.0 -3.0 2.0)A Free:(26.0 28.0 23.0)A ALB:(26.0 27.8 22.9)A
2025-10-24T13:04:49.203Z:USER:taskMaster.c:6599:Socket #1: L1N=236.5V L2N=237.5V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T13:13:56.097Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 26.0 23.0)A
2025-10-24T13:14:33.742Z:USER:taskMaster.c:6497:Temperature: 24.2 C
2025-10-24T13:19:49.109Z:USER:taskMaster.c:6599:Socket #1: L1N=236.8V L2N=237.6V L3N=237.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T13:23:56.035Z:INFO:active_lb.c:308:SMt:(-1.0 -3.0 1.0)A Free:(26.0 28.0 24.0)A ALB:(26.0 28.0 24.0)A
2025-10-24T13:29:34.097Z:USER:taskMaster.c:6497:Temperature: 24.1 C
2025-10-24T13:33:55.968Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(27.0 27.0 24.0)A ALB:(27.0 27.0 23.9)A
2025-10-24T13:34:49.015Z:USER:taskMaster.c:6599:Socket #1: L1N=235.6V L2N=234.9V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T13:43:55.906Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 5.0)A Free:(26.0 27.0 20.0)A ALB:(26.0 26.8 24.0)A
2025-10-24T13:44:34.503Z:USER:taskMaster.c:6497:Temperature: 24.4 C
2025-10-24T13:49:48.917Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=234.6V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T13:53:55.843Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(27.0 27.0 24.0)A ALB:(27.0 27.0 24.0)A
2025-10-24T13:59:34.859Z:USER:taskMaster.c:6497:Temperature: 24.4 C
2025-10-24T14:03:55.781Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 25.9 24.0)A
2025-10-24T14:04:48.824Z:USER:taskMaster.c:6599:Socket #1: L1N=235.2V L2N=235.1V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T14:13:55.714Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(24.0 25.9 24.0)A
2025-10-24T14:14:35.261Z:USER:taskMaster.c:6497:Temperature: 24.2 C
2025-10-24T14:19:48.730Z:USER:taskMaster.c:6599:Socket #1: L1N=234.3V L2N=234.6V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T14:23:55.652Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(27.0 27.0 24.0)A ALB:(27.0 27.0 24.0)A
2025-10-24T14:29:35.667Z:USER:taskMaster.c:6497:Temperature: 24.4 C
2025-10-24T14:33:55.589Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 26.0 23.0)A
2025-10-24T14:34:48.632Z:USER:taskMaster.c:6599:Socket #1: L1N=235.9V L2N=234.9V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T14:43:47.156Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-24T14:43:47.167Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-24T14:43:55.527Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 25.1 24.0)A
2025-10-24T14:44:35.972Z:USER:taskMaster.c:6497:Temperature: 24.2 C
2025-10-24T14:49:48.539Z:USER:taskMaster.c:6599:Socket #1: L1N=235.1V L2N=234.6V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T14:53:55.460Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(25.9 24.0 23.0)A
2025-10-24T14:59:36.378Z:USER:taskMaster.c:6497:Temperature: 24.2 C
2025-10-24T15:03:55.398Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(25.6 26.0 24.0)A
2025-10-24T15:04:48.445Z:USER:taskMaster.c:6599:Socket #1: L1N=235.7V L2N=236.5V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T15:13:55.335Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 25.9 24.0)A
2025-10-24T15:14:36.730Z:USER:taskMaster.c:6497:Temperature: 24.1 C
2025-10-24T15:19:48.347Z:USER:taskMaster.c:6599:Socket #1: L1N=231.3V L2N=231.9V L3N=230.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T15:23:55.273Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(24.0 24.0 23.4)A
2025-10-24T15:29:37.136Z:USER:taskMaster.c:6497:Temperature: 24.1 C
2025-10-24T15:33:55.207Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.4 24.0)A
2025-10-24T15:34:48.253Z:USER:taskMaster.c:6599:Socket #1: L1N=232.4V L2N=233.8V L3N=231.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T15:43:55.144Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 24.0 24.0)A
2025-10-24T15:44:37.542Z:USER:taskMaster.c:6497:Temperature: 24.0 C
2025-10-24T15:49:48.160Z:USER:taskMaster.c:6599:Socket #1: L1N=237.1V L2N=237.6V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T15:53:55.082Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T15:59:37.894Z:USER:taskMaster.c:6497:Temperature: 23.6 C
2025-10-24T16:03:55.019Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T16:04:48.062Z:USER:taskMaster.c:6599:Socket #1: L1N=234.4V L2N=234.0V L3N=232.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T16:13:54.957Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 22.3)A
2025-10-24T16:14:38.300Z:USER:taskMaster.c:6497:Temperature: 23.4 C
2025-10-24T16:19:47.968Z:USER:taskMaster.c:6599:Socket #1: L1N=233.3V L2N=234.4V L3N=232.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T16:23:54.890Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(23.0 23.0 24.0)A
2025-10-24T16:29:38.656Z:USER:taskMaster.c:6497:Temperature: 23.2 C
2025-10-24T16:33:54.828Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.2 24.0)A
2025-10-24T16:34:47.871Z:USER:taskMaster.c:6599:Socket #1: L1N=232.6V L2N=232.3V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T16:36:16.125Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-10-24T16:43:37.152Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-24T16:43:37.425Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-24T16:43:46.394Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-24T16:43:46.406Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-24T16:43:54.765Z:INFO:active_lb.c:308:SMt:(4.0 2.0 1.0)A Free:(21.0 23.0 24.0)A ALB:(14.7 23.0 23.6)A
2025-10-24T16:44:39.058Z:USER:taskMaster.c:6497:Temperature: 23.0 C
2025-10-24T16:46:16.058Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-10-24T16:49:47.777Z:USER:taskMaster.c:6599:Socket #1: L1N=232.8V L2N=233.4V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T16:53:54.699Z:INFO:active_lb.c:308:SMt:(3.0 2.0 1.0)A Free:(22.0 23.0 24.0)A ALB:(22.0 23.0 23.9)A
2025-10-24T16:56:16.097Z:INFO:taskLeds.c:338:Brightness set to 8%
2025-10-24T16:59:39.464Z:USER:taskMaster.c:6497:Temperature: 22.8 C
2025-10-24T17:03:54.636Z:INFO:active_lb.c:308:SMt:(2.0 3.0 4.0)A Free:(23.0 22.0 21.0)A ALB:(23.0 22.8 22.4)A
2025-10-24T17:04:47.679Z:USER:taskMaster.c:6599:Socket #1: L1N=233.3V L2N=233.5V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T17:13:54.574Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(23.0 23.0 23.8)A
2025-10-24T17:14:39.820Z:USER:taskMaster.c:6497:Temperature: 22.5 C
2025-10-24T17:19:47.585Z:USER:taskMaster.c:6599:Socket #1: L1N=233.7V L2N=233.1V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T17:23:54.507Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(23.0 23.0 24.0)A
2025-10-24T17:29:40.222Z:USER:taskMaster.c:6497:Temperature: 22.5 C
2025-10-24T17:33:54.445Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 22.9 24.0)A
2025-10-24T17:34:47.492Z:USER:taskMaster.c:6599:Socket #1: L1N=236.3V L2N=235.8V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T17:43:54.382Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-24T17:44:40.527Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-24T17:49:47.394Z:USER:taskMaster.c:6599:Socket #1: L1N=233.0V L2N=233.6V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T17:53:54.320Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 22.9 24.0)A
2025-10-24T17:59:40.933Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-24T18:03:54.253Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(24.0 22.0 23.0)A ALB:(24.0 22.4 23.4)A
2025-10-24T18:04:47.300Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=234.9V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T18:13:54.191Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-24T18:14:41.386Z:USER:taskMaster.c:6497:Temperature: 22.0 C
2025-10-24T18:19:47.203Z:USER:taskMaster.c:6599:Socket #1: L1N=237.0V L2N=236.8V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T18:23:54.128Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(23.9 23.0 24.0)A
2025-10-24T18:29:41.742Z:USER:taskMaster.c:6497:Temperature: 22.0 C
2025-10-24T18:33:54.062Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.3 24.0)A
2025-10-24T18:34:47.109Z:USER:taskMaster.c:6599:Socket #1: L1N=234.4V L2N=234.3V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T18:43:45.632Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-24T18:43:45.640Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-24T18:43:54.000Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.1 24.0)A
2025-10-24T18:44:42.093Z:USER:taskMaster.c:6497:Temperature: 21.9 C
2025-10-24T18:49:47.011Z:USER:taskMaster.c:6599:Socket #1: L1N=233.4V L2N=233.8V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T18:53:53.937Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 22.1 24.0)A
2025-10-24T18:59:42.449Z:USER:taskMaster.c:6497:Temperature: 21.9 C
2025-10-24T19:03:53.871Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.6 24.0)A
2025-10-24T19:04:46.917Z:USER:taskMaster.c:6599:Socket #1: L1N=232.6V L2N=232.4V L3N=231.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T19:13:53.808Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(22.6 22.1 24.0)A
2025-10-24T19:14:42.851Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-24T19:19:46.820Z:USER:taskMaster.c:6599:Socket #1: L1N=234.6V L2N=234.8V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T19:23:53.742Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(23.0 22.0 24.0)A ALB:(23.2 22.3 24.0)A
2025-10-24T19:29:43.257Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-24T19:33:53.679Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(24.0 21.0 24.0)A ALB:(24.0 22.6 24.0)A
2025-10-24T19:34:46.726Z:USER:taskMaster.c:6599:Socket #1: L1N=236.4V L2N=236.0V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T19:43:53.617Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 21.9 24.0)A
2025-10-24T19:44:43.613Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-24T19:49:46.628Z:USER:taskMaster.c:6599:Socket #1: L1N=235.4V L2N=235.7V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T19:53:53.550Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(23.0 23.0 24.0)A
2025-10-24T19:59:44.015Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-24T20:03:53.488Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(23.9 22.8 24.0)A
2025-10-24T20:04:46.531Z:USER:taskMaster.c:6599:Socket #1: L1N=235.6V L2N=235.6V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T20:13:53.425Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 23.4 24.0)A
2025-10-24T20:14:44.371Z:USER:taskMaster.c:6497:Temperature: 22.0 C
2025-10-24T20:19:46.437Z:USER:taskMaster.c:6599:Socket #1: L1N=233.5V L2N=234.1V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T20:23:53.359Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-24T20:29:44.824Z:USER:taskMaster.c:6497:Temperature: 21.9 C
2025-10-24T20:33:53.296Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.2 23.3 24.0)A
2025-10-24T20:34:46.339Z:USER:taskMaster.c:6599:Socket #1: L1N=234.4V L2N=234.6V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T20:43:35.328Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-24T20:43:35.597Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-24T20:43:44.863Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-24T20:43:44.875Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-24T20:43:53.234Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-24T20:43:53.332Z:INFO:comFaults.c:482:Reset fault status
2025-10-24T20:44:44.175Z:INFO:taskMaster.c:6294:Socket #1: no schedule
2025-10-24T20:44:44.183Z:USER:taskMaster.c:6318:Socket #1: external current limit 16.0 A
2025-10-24T20:44:45.226Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-24T20:49:46.246Z:USER:taskMaster.c:6599:Socket #1: L1N=234.9V L2N=235.5V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T20:53:53.167Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.2 24.0)A
2025-10-24T20:59:45.632Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-24T21:03:53.105Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T21:04:46.148Z:USER:taskMaster.c:6599:Socket #1: L1N=232.7V L2N=233.0V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T21:13:53.042Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 23.9 24.0)A
2025-10-24T21:14:46.085Z:USER:taskMaster.c:6497:Temperature: 21.9 C
2025-10-24T21:19:46.054Z:USER:taskMaster.c:6599:Socket #1: L1N=235.4V L2N=235.3V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T21:23:52.976Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.8 24.0 24.0)A
2025-10-24T21:29:46.492Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-24T21:33:52.914Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 23.8)A
2025-10-24T21:34:45.957Z:USER:taskMaster.c:6599:Socket #1: L1N=232.9V L2N=232.8V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T21:43:52.851Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-24T21:44:46.945Z:USER:taskMaster.c:6497:Temperature: 21.6 C
2025-10-24T21:49:45.863Z:USER:taskMaster.c:6599:Socket #1: L1N=234.3V L2N=233.9V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T21:53:52.785Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T21:59:47.398Z:USER:taskMaster.c:6497:Temperature: 21.4 C
2025-10-24T22:03:52.722Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.1 24.0 24.0)A
2025-10-24T22:04:45.765Z:USER:taskMaster.c:6599:Socket #1: L1N=233.6V L2N=233.3V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T22:13:52.660Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T22:14:47.851Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-24T22:19:45.671Z:USER:taskMaster.c:6599:Socket #1: L1N=232.8V L2N=232.4V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T22:23:52.593Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T22:29:48.304Z:USER:taskMaster.c:6497:Temperature: 21.4 C
2025-10-24T22:33:52.531Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T22:34:45.574Z:USER:taskMaster.c:6599:Socket #1: L1N=234.5V L2N=234.4V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T22:43:44.097Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-24T22:43:44.109Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-24T22:43:52.464Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.6 24.0 24.0)A
2025-10-24T22:44:48.808Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-24T22:49:45.480Z:USER:taskMaster.c:6599:Socket #1: L1N=235.5V L2N=235.1V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T22:53:52.402Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T22:59:49.214Z:USER:taskMaster.c:6497:Temperature: 21.4 C
2025-10-24T23:03:52.339Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T23:04:45.382Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=234.7V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T23:13:52.273Z:INFO:active_lb.c:308:SMt:(8.0 1.0 1.0)A Free:(17.0 24.0 24.0)A ALB:(17.1 24.0 24.0)A
2025-10-24T23:14:49.617Z:USER:taskMaster.c:6497:Temperature: 21.2 C
2025-10-24T23:19:45.285Z:USER:taskMaster.c:6599:Socket #1: L1N=233.1V L2N=233.4V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T23:23:52.210Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-24T23:29:50.074Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-24T23:33:52.148Z:INFO:active_lb.c:308:SMt:(8.0 6.0 1.0)A Free:(17.0 19.0 24.0)A ALB:(17.0 19.0 24.0)A
2025-10-24T23:34:45.191Z:USER:taskMaster.c:6599:Socket #1: L1N=233.4V L2N=234.1V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T23:43:52.082Z:INFO:active_lb.c:308:SMt:(1.0 6.0 1.0)A Free:(24.0 19.0 24.0)A ALB:(24.0 19.0 24.0)A
2025-10-24T23:44:50.476Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-24T23:49:45.093Z:USER:taskMaster.c:6599:Socket #1: L1N=235.5V L2N=235.3V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-24T23:53:52.019Z:INFO:active_lb.c:308:SMt:(1.0 6.0 1.0)A Free:(24.0 19.0 24.0)A ALB:(23.4 19.0 24.0)A
2025-10-24T23:59:50.929Z:USER:taskMaster.c:6497:Temperature: 21.0 C
2025-10-25T00:03:51.953Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 22.8 24.0)A
2025-10-25T00:04:45.000Z:USER:taskMaster.c:6599:Socket #1: L1N=234.2V L2N=234.4V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T00:13:51.890Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T00:14:51.335Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-25T00:19:44.902Z:USER:taskMaster.c:6599:Socket #1: L1N=235.3V L2N=235.6V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T00:23:51.828Z:INFO:active_lb.c:308:SMt:(9.0 1.0 1.0)A Free:(16.0 24.0 24.0)A ALB:(16.2 24.0 24.0)A
2025-10-25T00:29:51.839Z:USER:taskMaster.c:6497:Temperature: 21.2 C
2025-10-25T00:33:51.761Z:INFO:active_lb.c:308:SMt:(9.0 1.0 1.0)A Free:(16.0 24.0 24.0)A ALB:(16.0 24.0 24.0)A
2025-10-25T00:34:44.808Z:USER:taskMaster.c:6599:Socket #1: L1N=232.0V L2N=233.3V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T00:43:33.585Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-25T00:43:33.855Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-25T00:43:43.332Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-25T00:43:43.339Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-25T00:43:51.699Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T00:44:52.242Z:USER:taskMaster.c:6497:Temperature: 21.4 C
2025-10-25T00:49:44.710Z:USER:taskMaster.c:6599:Socket #1: L1N=235.5V L2N=235.4V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T00:53:51.632Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 24.0 24.0)A
2025-10-25T00:59:52.644Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-25T01:03:51.570Z:INFO:active_lb.c:308:SMt:(3.0 1.0 1.0)A Free:(22.0 24.0 24.0)A ALB:(22.1 24.0 24.0)A
2025-10-25T01:04:44.613Z:USER:taskMaster.c:6599:Socket #1: L1N=235.3V L2N=235.8V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T01:13:51.507Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T01:14:53.101Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-25T01:19:44.519Z:USER:taskMaster.c:6599:Socket #1: L1N=235.9V L2N=236.7V L3N=236.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T01:23:51.441Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T01:29:53.554Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-25T01:33:51.378Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T01:34:44.421Z:USER:taskMaster.c:6599:Socket #1: L1N=236.5V L2N=237.5V L3N=237.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T01:43:51.312Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 23.1 24.0)A
2025-10-25T01:44:53.558Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-25T01:49:44.328Z:USER:taskMaster.c:6599:Socket #1: L1N=236.8V L2N=237.8V L3N=237.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T01:53:51.250Z:INFO:active_lb.c:308:SMt:(1.0 7.0 1.0)A Free:(24.0 18.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T01:59:54.414Z:USER:taskMaster.c:6497:Temperature: 21.4 C
2025-10-25T02:03:51.187Z:INFO:active_lb.c:308:SMt:(1.0 7.0 1.0)A Free:(24.0 18.0 24.0)A ALB:(24.0 18.0 24.0)A
2025-10-25T02:04:44.230Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=234.2V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T02:13:51.121Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 21.8 24.0)A
2025-10-25T02:14:54.867Z:USER:taskMaster.c:6497:Temperature: 21.4 C
2025-10-25T02:19:44.136Z:USER:taskMaster.c:6599:Socket #1: L1N=234.5V L2N=234.9V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T02:23:51.058Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T02:29:55.320Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-25T02:33:50.996Z:INFO:active_lb.c:308:SMt:(1.0 6.0 1.0)A Free:(24.0 19.0 24.0)A ALB:(24.0 19.0 24.0)A
2025-10-25T02:34:44.039Z:USER:taskMaster.c:6599:Socket #1: L1N=234.4V L2N=234.3V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T02:43:42.562Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-25T02:43:42.574Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-25T02:43:50.929Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T02:44:55.773Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-25T02:49:43.941Z:USER:taskMaster.c:6599:Socket #1: L1N=233.8V L2N=233.9V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T02:53:50.867Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T02:59:56.179Z:USER:taskMaster.c:6497:Temperature: 21.6 C
2025-10-25T03:03:50.800Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T03:04:43.847Z:USER:taskMaster.c:6599:Socket #1: L1N=233.4V L2N=233.5V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T03:13:50.738Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T03:14:56.933Z:USER:taskMaster.c:6497:Temperature: 21.6 C
2025-10-25T03:19:43.750Z:USER:taskMaster.c:6599:Socket #1: L1N=233.6V L2N=234.3V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T03:23:50.675Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T03:29:57.085Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-25T03:33:50.609Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T03:34:43.656Z:USER:taskMaster.c:6599:Socket #1: L1N=232.6V L2N=233.2V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T03:43:50.546Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T03:44:57.539Z:USER:taskMaster.c:6497:Temperature: 21.6 C
2025-10-25T03:49:43.558Z:USER:taskMaster.c:6599:Socket #1: L1N=233.2V L2N=233.6V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T03:53:50.484Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T03:59:57.992Z:USER:taskMaster.c:6497:Temperature: 21.6 C
2025-10-25T04:03:50.417Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T04:04:43.464Z:USER:taskMaster.c:6599:Socket #1: L1N=237.6V L2N=237.9V L3N=237.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T04:13:50.355Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T04:14:58.449Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-25T04:19:43.367Z:USER:taskMaster.c:6599:Socket #1: L1N=234.5V L2N=234.9V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T04:23:50.292Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T04:29:58.902Z:USER:taskMaster.c:6497:Temperature: 21.6 C
2025-10-25T04:33:50.226Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T04:34:43.273Z:USER:taskMaster.c:6599:Socket #1: L1N=234.2V L2N=234.3V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T04:43:32.867Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-25T04:43:33.140Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-25T04:43:41.796Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-25T04:43:41.804Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-25T04:43:50.164Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T04:44:59.304Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-25T04:49:43.175Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=233.9V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T04:53:50.097Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T04:59:59.761Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-25T05:03:50.035Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T05:04:43.078Z:USER:taskMaster.c:6599:Socket #1: L1N=232.3V L2N=232.4V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T05:13:49.972Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T05:15:00.164Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-25T05:19:42.984Z:USER:taskMaster.c:6599:Socket #1: L1N=235.9V L2N=235.9V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T05:23:49.906Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T05:30:00.570Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-25T05:33:49.843Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T05:34:42.886Z:USER:taskMaster.c:6599:Socket #1: L1N=234.6V L2N=235.4V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T05:43:49.781Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.1 24.0 24.0)A
2025-10-25T05:45:01.023Z:USER:taskMaster.c:6497:Temperature: 21.9 C
2025-10-25T05:49:42.792Z:USER:taskMaster.c:6599:Socket #1: L1N=233.6V L2N=233.6V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T05:52:01.339Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-10-25T05:53:49.714Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T06:00:01.527Z:USER:taskMaster.c:6497:Temperature: 22.0 C
2025-10-25T06:02:01.375Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-10-25T06:03:49.652Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T06:04:42.695Z:USER:taskMaster.c:6599:Socket #1: L1N=233.3V L2N=233.6V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T06:12:01.410Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-10-25T06:13:49.589Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T06:15:01.878Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-25T06:19:42.601Z:USER:taskMaster.c:6599:Socket #1: L1N=234.6V L2N=235.8V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T06:23:49.523Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T06:30:02.335Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-25T06:33:49.460Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T06:34:42.503Z:USER:taskMaster.c:6599:Socket #1: L1N=233.6V L2N=234.6V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T06:43:41.027Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-25T06:43:41.039Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-25T06:43:49.398Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T06:45:02.789Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-25T06:49:42.410Z:USER:taskMaster.c:6599:Socket #1: L1N=236.3V L2N=236.9V L3N=236.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T06:53:49.332Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T07:00:03.343Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-25T07:03:49.269Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T07:04:42.312Z:USER:taskMaster.c:6599:Socket #1: L1N=235.5V L2N=236.1V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T07:13:49.207Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T07:15:03.796Z:USER:taskMaster.c:6497:Temperature: 22.6 C
2025-10-25T07:19:42.218Z:USER:taskMaster.c:6599:Socket #1: L1N=236.6V L2N=236.4V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T07:23:49.140Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(24.6 24.0 24.0)A
2025-10-25T07:30:04.300Z:USER:taskMaster.c:6497:Temperature: 22.6 C
2025-10-25T07:33:49.078Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T07:34:42.121Z:USER:taskMaster.c:6599:Socket #1: L1N=235.5V L2N=235.1V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T07:43:49.015Z:INFO:active_lb.c:308:SMt:(2.0 1.0 2.0)A Free:(23.0 24.0 23.0)A ALB:(23.4 24.0 23.0)A
2025-10-25T07:45:04.656Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-25T07:49:42.027Z:USER:taskMaster.c:6599:Socket #1: L1N=235.9V L2N=235.3V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T07:53:48.949Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.0 24.0 23.4)A
2025-10-25T08:00:05.062Z:USER:taskMaster.c:6497:Temperature: 23.2 C
2025-10-25T08:03:48.886Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.0 24.0 23.0)A
2025-10-25T08:04:41.929Z:USER:taskMaster.c:6599:Socket #1: L1N=236.9V L2N=237.2V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T08:13:48.824Z:INFO:active_lb.c:308:SMt:(1.0 6.0 1.0)A Free:(24.0 19.0 24.0)A ALB:(24.7 19.4 23.7)A
2025-10-25T08:15:05.515Z:USER:taskMaster.c:6497:Temperature: 23.5 C
2025-10-25T08:19:41.835Z:USER:taskMaster.c:6599:Socket #1: L1N=235.5V L2N=235.3V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T08:23:48.757Z:INFO:active_lb.c:308:SMt:(-1.0 6.0 2.0)A Free:(26.0 19.0 23.0)A ALB:(26.0 19.0 23.0)A
2025-10-25T08:30:06.121Z:USER:taskMaster.c:6497:Temperature: 23.9 C
2025-10-25T08:33:48.695Z:INFO:active_lb.c:308:SMt:(-1.0 6.0 1.0)A Free:(26.0 19.0 24.0)A ALB:(26.0 18.9 24.0)A
2025-10-25T08:34:41.742Z:USER:taskMaster.c:6599:Socket #1: L1N=234.0V L2N=232.5V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T08:43:31.164Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-25T08:43:31.433Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-25T08:43:40.265Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-25T08:43:40.273Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-25T08:43:48.632Z:INFO:active_lb.c:308:SMt:(1.0 16.0 1.0)A Free:(24.0 9.0 24.0)A ALB:(23.0 9.1 24.0)A
2025-10-25T08:43:48.730Z:INFO:comFaults.c:482:Reset fault status
2025-10-25T08:43:50.375Z:COM:ocpp_rpc.c:715:-> [2,"28","Heartbeat",{}]
2025-10-25T08:43:50.406Z:COM:ocpp_rpc.c:1292:<- [3,"28",{"currentTime":"2025-10-25T08:43:55.825Z"}]
2025-10-25T08:43:55.000Z:SECURITY:taskTime.c:603:Time changed
2025-10-25T08:45:10.957Z:USER:taskMaster.c:6497:Temperature: 23.9 C
2025-10-25T08:49:46.226Z:USER:taskMaster.c:6599:Socket #1: L1N=235.4V L2N=234.7V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T08:53:53.148Z:INFO:active_lb.c:308:SMt:(-1.0 16.0 1.0)A Free:(26.0 9.0 24.0)A ALB:(26.0 17.6 24.0)A
2025-10-25T09:00:11.609Z:USER:taskMaster.c:6497:Temperature: 24.0 C
2025-10-25T09:03:53.085Z:INFO:active_lb.c:308:SMt:(-2.0 7.0 1.0)A Free:(27.0 18.0 24.0)A ALB:(26.8 17.4 24.0)A
2025-10-25T09:04:46.132Z:USER:taskMaster.c:6599:Socket #1: L1N=236.8V L2N=236.1V L3N=235.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T09:13:53.023Z:INFO:active_lb.c:308:SMt:(-1.0 7.0 1.0)A Free:(26.0 18.0 24.0)A ALB:(26.0 15.2 24.0)A
2025-10-25T09:15:12.066Z:USER:taskMaster.c:6497:Temperature: 24.9 C
2025-10-25T09:19:46.035Z:USER:taskMaster.c:6599:Socket #1: L1N=235.7V L2N=233.6V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T09:23:52.960Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 22.6 24.0)A
2025-10-25T09:30:12.468Z:USER:taskMaster.c:6497:Temperature: 24.8 C
2025-10-25T09:33:52.894Z:INFO:active_lb.c:308:SMt:(2.0 11.0 1.0)A Free:(23.0 14.0 24.0)A ALB:(23.4 22.9 24.0)A
2025-10-25T09:34:45.941Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=234.5V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T09:43:52.832Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(23.2 23.0 24.0)A
2025-10-25T09:45:12.875Z:USER:taskMaster.c:6497:Temperature: 24.2 C
2025-10-25T09:49:45.843Z:USER:taskMaster.c:6599:Socket #1: L1N=233.7V L2N=234.2V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T09:53:52.769Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.4 23.2 24.0)A
2025-10-25T10:00:13.281Z:USER:taskMaster.c:6497:Temperature: 24.2 C
2025-10-25T10:03:52.707Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-25T10:04:45.750Z:USER:taskMaster.c:6599:Socket #1: L1N=236.7V L2N=236.4V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T10:13:52.644Z:INFO:active_lb.c:308:SMt:(5.0 2.0 1.0)A Free:(20.0 23.0 24.0)A ALB:(20.0 23.0 23.9)A
2025-10-25T10:15:13.785Z:USER:taskMaster.c:6497:Temperature: 24.2 C
2025-10-25T10:19:45.656Z:USER:taskMaster.c:6599:Socket #1: L1N=236.0V L2N=236.4V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T10:23:52.578Z:INFO:active_lb.c:308:SMt:(18.0 2.0 1.0)A Free:(7.0 23.0 24.0)A ALB:(7.7 22.9 24.0)A
2025-10-25T10:30:14.140Z:USER:taskMaster.c:6497:Temperature: 24.5 C
2025-10-25T10:33:52.515Z:INFO:active_lb.c:308:SMt:(4.0 -1.0 1.0)A Free:(21.0 26.0 24.0)A ALB:(21.0 25.8 24.0)A
2025-10-25T10:34:45.558Z:USER:taskMaster.c:6599:Socket #1: L1N=237.7V L2N=237.5V L3N=236.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T10:43:44.085Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-25T10:43:44.093Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-25T10:43:52.453Z:INFO:active_lb.c:308:SMt:(-2.0 4.0 2.0)A Free:(27.0 21.0 23.0)A ALB:(27.0 21.1 23.0)A
2025-10-25T10:45:14.593Z:USER:taskMaster.c:6497:Temperature: 24.9 C
2025-10-25T10:49:45.464Z:USER:taskMaster.c:6599:Socket #1: L1N=236.0V L2N=235.6V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T10:53:52.390Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(25.1 24.0 24.0)A
2025-10-25T11:00:15.000Z:USER:taskMaster.c:6497:Temperature: 24.9 C
2025-10-25T11:03:52.324Z:INFO:active_lb.c:308:SMt:(-2.0 3.0 1.0)A Free:(27.0 22.0 24.0)A ALB:(27.0 22.0 24.0)A
2025-10-25T11:04:45.371Z:USER:taskMaster.c:6599:Socket #1: L1N=234.8V L2N=236.0V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T11:13:52.261Z:INFO:active_lb.c:308:SMt:(-1.0 3.0 1.0)A Free:(26.0 22.0 24.0)A ALB:(26.0 22.0 24.0)A
2025-10-25T11:15:15.453Z:USER:taskMaster.c:6497:Temperature: 24.5 C
2025-10-25T11:19:45.273Z:USER:taskMaster.c:6599:Socket #1: L1N=235.7V L2N=236.5V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T11:23:52.199Z:INFO:active_lb.c:308:SMt:(-2.0 2.0 1.0)A Free:(27.0 23.0 24.0)A ALB:(26.9 22.7 24.0)A
2025-10-25T11:30:15.859Z:USER:taskMaster.c:6497:Temperature: 24.5 C
2025-10-25T11:33:52.136Z:INFO:active_lb.c:308:SMt:(-2.0 1.0 1.0)A Free:(27.0 24.0 24.0)A ALB:(27.0 23.4 24.0)A
2025-10-25T11:34:45.179Z:USER:taskMaster.c:6599:Socket #1: L1N=236.0V L2N=235.0V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T11:43:52.070Z:INFO:active_lb.c:308:SMt:(-2.0 2.0 1.0)A Free:(27.0 23.0 24.0)A ALB:(27.0 23.0 24.0)A
2025-10-25T11:45:16.261Z:USER:taskMaster.c:6497:Temperature: 25.0 C
2025-10-25T11:49:45.085Z:USER:taskMaster.c:6599:Socket #1: L1N=234.5V L2N=234.1V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T11:53:52.007Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-25T12:00:16.718Z:USER:taskMaster.c:6497:Temperature: 25.1 C
2025-10-25T12:03:51.945Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(25.3 21.7 24.0)A
2025-10-25T12:04:44.988Z:USER:taskMaster.c:6599:Socket #1: L1N=236.1V L2N=235.7V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T12:13:51.882Z:INFO:active_lb.c:308:SMt:(-1.0 5.0 1.0)A Free:(26.0 20.0 24.0)A ALB:(26.0 20.0 24.0)A
2025-10-25T12:15:17.125Z:USER:taskMaster.c:6497:Temperature: 25.1 C
2025-10-25T12:19:44.894Z:USER:taskMaster.c:6599:Socket #1: L1N=236.0V L2N=235.7V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T12:23:51.816Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 1.0)A Free:(26.0 23.0 24.0)A ALB:(26.0 23.0 24.0)A
2025-10-25T12:30:17.128Z:USER:taskMaster.c:6497:Temperature: 25.0 C
2025-10-25T12:33:51.753Z:INFO:active_lb.c:308:SMt:(-3.0 -1.0 1.0)A Free:(28.0 26.0 24.0)A ALB:(27.6 26.7 24.0)A
2025-10-25T12:34:44.800Z:USER:taskMaster.c:6599:Socket #1: L1N=237.6V L2N=237.2V L3N=237.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T12:43:34.031Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-25T12:43:34.300Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-25T12:43:43.324Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-25T12:43:43.335Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-25T12:43:51.691Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(27.0 27.0 24.0)A ALB:(27.0 27.0 24.0)A
2025-10-25T12:45:17.980Z:USER:taskMaster.c:6497:Temperature: 25.4 C
2025-10-25T12:49:44.703Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=233.9V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T12:53:51.628Z:INFO:active_lb.c:308:SMt:(-1.0 3.0 1.0)A Free:(26.0 22.0 24.0)A ALB:(25.6 22.0 24.0)A
2025-10-25T13:00:18.437Z:USER:taskMaster.c:6497:Temperature: 25.1 C
2025-10-25T13:03:51.566Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 23.8 24.0)A
2025-10-25T13:04:44.609Z:USER:taskMaster.c:6599:Socket #1: L1N=234.0V L2N=233.8V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T13:13:51.500Z:INFO:active_lb.c:308:SMt:(-3.0 -3.0 1.0)A Free:(28.0 28.0 24.0)A ALB:(27.3 27.7 24.0)A
2025-10-25T13:15:18.843Z:USER:taskMaster.c:6497:Temperature: 24.9 C
2025-10-25T13:19:44.515Z:USER:taskMaster.c:6599:Socket #1: L1N=236.6V L2N=235.9V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T13:23:51.437Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 1.0)A Free:(26.0 23.0 24.0)A ALB:(26.6 24.6 24.0)A
2025-10-25T13:30:19.296Z:USER:taskMaster.c:6497:Temperature: 24.8 C
2025-10-25T13:33:51.375Z:INFO:active_lb.c:308:SMt:(-2.0 -1.0 1.0)A Free:(27.0 26.0 24.0)A ALB:(27.0 26.0 24.0)A
2025-10-25T13:34:44.417Z:USER:taskMaster.c:6599:Socket #1: L1N=236.8V L2N=236.4V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T13:43:51.312Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 23.4 24.0)A
2025-10-25T13:45:19.703Z:USER:taskMaster.c:6497:Temperature: 25.2 C
2025-10-25T13:49:44.324Z:USER:taskMaster.c:6599:Socket #1: L1N=235.0V L2N=234.5V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T13:53:51.250Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.3 24.0 24.0)A
2025-10-25T14:00:20.109Z:USER:taskMaster.c:6497:Temperature: 25.0 C
2025-10-25T14:03:51.183Z:INFO:active_lb.c:308:SMt:(-1.0 8.0 1.0)A Free:(26.0 17.0 24.0)A ALB:(26.0 17.3 24.0)A
2025-10-25T14:04:44.230Z:USER:taskMaster.c:6599:Socket #1: L1N=232.8V L2N=232.6V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T14:13:51.121Z:INFO:active_lb.c:308:SMt:(7.0 8.0 1.0)A Free:(18.0 17.0 24.0)A ALB:(19.4 17.0 24.0)A
2025-10-25T14:15:20.562Z:USER:taskMaster.c:6497:Temperature: 24.9 C
2025-10-25T14:19:44.132Z:USER:taskMaster.c:6599:Socket #1: L1N=234.5V L2N=235.5V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T14:23:51.058Z:INFO:active_lb.c:308:SMt:(6.0 1.0 1.0)A Free:(19.0 24.0 24.0)A ALB:(19.0 24.0 24.0)A
2025-10-25T14:30:21.066Z:USER:taskMaster.c:6497:Temperature: 24.9 C
2025-10-25T14:33:50.996Z:INFO:active_lb.c:308:SMt:(7.0 4.0 1.0)A Free:(18.0 21.0 24.0)A ALB:(18.0 20.9 24.0)A
2025-10-25T14:34:44.039Z:USER:taskMaster.c:6599:Socket #1: L1N=235.9V L2N=235.9V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T14:43:42.562Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-25T14:43:42.574Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-25T14:43:50.929Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(24.0 23.0 23.0)A ALB:(24.0 23.6 23.6)A
2025-10-25T14:45:21.421Z:USER:taskMaster.c:6497:Temperature: 24.8 C
2025-10-25T14:49:43.945Z:USER:taskMaster.c:6599:Socket #1: L1N=233.7V L2N=234.3V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T14:53:50.867Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(23.0 22.0 24.0)A ALB:(23.0 22.0 24.0)A
2025-10-25T15:00:21.828Z:USER:taskMaster.c:6497:Temperature: 24.8 C
2025-10-25T15:03:50.804Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 1.0)A Free:(26.0 23.0 24.0)A ALB:(22.5 23.0 24.0)A
2025-10-25T15:04:43.847Z:USER:taskMaster.c:6599:Socket #1: L1N=235.1V L2N=236.7V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T15:13:50.742Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 23.9 24.0)A
2025-10-25T15:15:22.281Z:USER:taskMaster.c:6497:Temperature: 24.5 C
2025-10-25T15:19:43.753Z:USER:taskMaster.c:6599:Socket #1: L1N=231.8V L2N=232.0V L3N=231.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T15:23:50.679Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.9 24.0 24.0)A
2025-10-25T15:30:22.738Z:USER:taskMaster.c:6497:Temperature: 24.4 C
2025-10-25T15:33:50.613Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.2 24.0 24.0)A
2025-10-25T15:34:43.660Z:USER:taskMaster.c:6599:Socket #1: L1N=232.2V L2N=231.2V L3N=231.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T15:43:50.550Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(22.4 24.0 24.0)A
2025-10-25T15:45:23.140Z:USER:taskMaster.c:6497:Temperature: 24.0 C
2025-10-25T15:49:43.562Z:USER:taskMaster.c:6599:Socket #1: L1N=230.2V L2N=230.6V L3N=230.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T15:53:50.488Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.2 24.0 24.0)A
2025-10-25T16:00:23.597Z:USER:taskMaster.c:6497:Temperature: 23.9 C
2025-10-25T16:03:50.425Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(23.1 23.0 24.0)A
2025-10-25T16:04:43.468Z:USER:taskMaster.c:6599:Socket #1: L1N=229.6V L2N=229.4V L3N=227.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T16:13:50.359Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(24.0 23.3 24.0)A
2025-10-25T16:15:24.101Z:USER:taskMaster.c:6497:Temperature: 23.5 C
2025-10-25T16:19:43.375Z:USER:taskMaster.c:6599:Socket #1: L1N=232.6V L2N=231.3V L3N=231.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T16:23:50.296Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-25T16:30:24.503Z:USER:taskMaster.c:6497:Temperature: 23.4 C
2025-10-25T16:33:50.234Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 23.4 24.0)A
2025-10-25T16:34:12.640Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-10-25T16:34:43.328Z:USER:taskMaster.c:6599:Socket #1: L1N=232.4V L2N=232.0V L3N=231.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T16:43:32.316Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-25T16:43:32.585Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-25T16:43:41.800Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-25T16:43:41.812Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-25T16:43:50.167Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(23.0 23.0 24.0)A
2025-10-25T16:44:12.679Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-10-25T16:45:24.910Z:USER:taskMaster.c:6497:Temperature: 23.2 C
2025-10-25T16:49:43.234Z:USER:taskMaster.c:6599:Socket #1: L1N=231.7V L2N=231.2V L3N=229.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T16:53:50.105Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-25T16:54:12.714Z:INFO:taskLeds.c:338:Brightness set to 8%
2025-10-25T17:00:25.316Z:USER:taskMaster.c:6497:Temperature: 22.8 C
2025-10-25T17:03:50.042Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-25T17:04:43.136Z:USER:taskMaster.c:6599:Socket #1: L1N=228.2V L2N=227.2V L3N=227.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T17:13:49.980Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(23.0 23.0 24.0)A
2025-10-25T17:15:25.718Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-25T17:19:43.042Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=233.8V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T17:23:49.914Z:INFO:active_lb.c:308:SMt:(1.0 2.0 10.0)A Free:(24.0 23.0 15.0)A ALB:(24.0 23.0 19.6)A
2025-10-25T17:30:26.222Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-25T17:33:49.851Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.1 24.0 24.0)A
2025-10-25T17:34:42.945Z:USER:taskMaster.c:6599:Socket #1: L1N=235.0V L2N=234.9V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T17:43:49.789Z:INFO:active_lb.c:308:SMt:(5.0 2.0 1.0)A Free:(20.0 23.0 24.0)A ALB:(21.6 23.0 24.0)A
2025-10-25T17:45:26.628Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-25T17:49:42.851Z:USER:taskMaster.c:6599:Socket #1: L1N=229.0V L2N=229.6V L3N=229.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T17:53:49.722Z:INFO:active_lb.c:308:SMt:(5.0 2.0 1.0)A Free:(20.0 23.0 24.0)A ALB:(24.0 22.9 24.0)A
2025-10-25T18:00:27.082Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-25T18:03:49.660Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-25T18:04:42.753Z:USER:taskMaster.c:6599:Socket #1: L1N=233.9V L2N=233.2V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T18:13:49.597Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-25T18:15:27.636Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-25T18:19:42.660Z:USER:taskMaster.c:6599:Socket #1: L1N=234.5V L2N=234.4V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T18:23:49.531Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(23.8 22.0 24.0)A
2025-10-25T18:30:27.941Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-25T18:33:49.468Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(23.7 23.0 24.0)A
2025-10-25T18:34:42.562Z:USER:taskMaster.c:6599:Socket #1: L1N=234.2V L2N=234.1V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T18:43:41.035Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-25T18:43:41.046Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-25T18:43:49.406Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(23.0 22.0 24.0)A ALB:(23.6 22.0 24.0)A
2025-10-25T18:45:28.394Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-25T18:49:42.468Z:USER:taskMaster.c:6599:Socket #1: L1N=231.8V L2N=233.2V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T18:53:49.339Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 22.1 24.0)A
2025-10-25T19:00:28.398Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-25T19:03:49.277Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 22.9 24.0)A
2025-10-25T19:04:42.371Z:USER:taskMaster.c:6599:Socket #1: L1N=231.1V L2N=231.4V L3N=231.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T19:13:49.214Z:INFO:active_lb.c:308:SMt:(7.0 2.0 1.0)A Free:(18.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-25T19:15:29.253Z:USER:taskMaster.c:6497:Temperature: 21.9 C
2025-10-25T19:19:42.277Z:USER:taskMaster.c:6599:Socket #1: L1N=232.9V L2N=233.3V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T19:23:49.148Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 22.7 24.0)A
2025-10-25T19:30:29.707Z:USER:taskMaster.c:6497:Temperature: 21.9 C
2025-10-25T19:33:49.085Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 22.2 24.0)A
2025-10-25T19:34:42.179Z:USER:taskMaster.c:6599:Socket #1: L1N=230.6V L2N=231.4V L3N=231.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T19:43:49.023Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-25T19:45:30.160Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-25T19:49:42.085Z:USER:taskMaster.c:6599:Socket #1: L1N=235.4V L2N=235.6V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T19:53:48.957Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-25T20:00:30.617Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-25T20:03:48.894Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.3 24.0)A
2025-10-25T20:04:41.988Z:USER:taskMaster.c:6599:Socket #1: L1N=235.4V L2N=235.9V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T20:13:48.832Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-25T20:15:31.019Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-25T20:19:41.894Z:USER:taskMaster.c:6599:Socket #1: L1N=233.2V L2N=233.8V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T20:23:48.765Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 23.7 24.0)A
2025-10-25T20:30:31.472Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-25T20:33:48.703Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(23.4 22.0 24.0)A
2025-10-25T20:34:41.796Z:USER:taskMaster.c:6599:Socket #1: L1N=233.6V L2N=234.1V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T20:43:31.597Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-25T20:43:31.867Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-25T20:43:40.269Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-25T20:43:40.281Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-25T20:43:48.636Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 22.9 24.0)A
2025-10-25T20:43:48.738Z:INFO:comFaults.c:482:Reset fault status
2025-10-25T20:45:31.878Z:USER:taskMaster.c:6497:Temperature: 21.0 C
2025-10-25T20:49:41.699Z:USER:taskMaster.c:6599:Socket #1: L1N=234.4V L2N=234.6V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T20:53:48.574Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.3 24.0)A
2025-10-25T21:00:32.382Z:USER:taskMaster.c:6497:Temperature: 21.2 C
2025-10-25T21:03:48.511Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T21:04:41.605Z:USER:taskMaster.c:6599:Socket #1: L1N=232.3V L2N=232.2V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T21:13:48.445Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T21:15:32.886Z:USER:taskMaster.c:6497:Temperature: 21.2 C
2025-10-25T21:19:41.507Z:USER:taskMaster.c:6599:Socket #1: L1N=234.9V L2N=234.9V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T21:23:48.382Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 23.9 24.0)A
2025-10-25T21:30:33.238Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-25T21:33:48.316Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T21:34:41.414Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=234.6V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T21:43:48.253Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.2 24.0 24.0)A
2025-10-25T21:45:33.742Z:USER:taskMaster.c:6497:Temperature: 21.2 C
2025-10-25T21:49:41.316Z:USER:taskMaster.c:6599:Socket #1: L1N=234.5V L2N=234.8V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T21:53:48.191Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.2 24.0 23.8)A
2025-10-25T22:00:34.195Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-25T22:03:48.125Z:INFO:active_lb.c:308:SMt:(1.0 6.0 1.0)A Free:(24.0 19.0 24.0)A ALB:(24.0 19.0 24.0)A
2025-10-25T22:04:41.218Z:USER:taskMaster.c:6599:Socket #1: L1N=236.2V L2N=235.9V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T22:13:48.062Z:INFO:active_lb.c:308:SMt:(1.0 6.0 1.0)A Free:(24.0 19.0 24.0)A ALB:(24.0 18.7 24.0)A
2025-10-25T22:15:34.601Z:USER:taskMaster.c:6497:Temperature: 20.9 C
2025-10-25T22:19:41.125Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=234.9V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T22:23:47.996Z:INFO:active_lb.c:308:SMt:(1.0 7.0 1.0)A Free:(24.0 18.0 24.0)A ALB:(24.0 18.0 24.0)A
2025-10-25T22:30:35.003Z:USER:taskMaster.c:6497:Temperature: 21.0 C
2025-10-25T22:33:47.933Z:INFO:active_lb.c:308:SMt:(1.0 7.0 1.0)A Free:(24.0 18.0 24.0)A ALB:(23.6 18.0 24.0)A
2025-10-25T22:34:41.027Z:USER:taskMaster.c:6599:Socket #1: L1N=234.2V L2N=233.8V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T22:43:39.500Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-25T22:43:39.511Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-25T22:43:47.871Z:INFO:active_lb.c:308:SMt:(2.0 6.0 1.0)A Free:(23.0 19.0 24.0)A ALB:(23.1 19.0 24.0)A
2025-10-25T22:45:35.457Z:USER:taskMaster.c:6497:Temperature: 21.0 C
2025-10-25T22:49:40.933Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=234.6V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T22:53:47.804Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T23:00:35.863Z:USER:taskMaster.c:6497:Temperature: 20.9 C
2025-10-25T23:03:47.742Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 24.0 24.0)A
2025-10-25T23:04:40.835Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=234.8V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T23:13:47.675Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T23:15:36.316Z:USER:taskMaster.c:6497:Temperature: 20.9 C
2025-10-25T23:19:40.738Z:USER:taskMaster.c:6599:Socket #1: L1N=235.2V L2N=235.8V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T23:23:47.613Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T23:30:36.769Z:USER:taskMaster.c:6497:Temperature: 21.0 C
2025-10-25T23:33:47.550Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T23:34:40.644Z:USER:taskMaster.c:6599:Socket #1: L1N=236.2V L2N=236.6V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T23:43:47.484Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-25T23:45:37.222Z:USER:taskMaster.c:6497:Temperature: 20.5 C
2025-10-25T23:49:40.546Z:USER:taskMaster.c:6599:Socket #1: L1N=235.7V L2N=236.2V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-25T23:53:47.421Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T00:00:37.679Z:USER:taskMaster.c:6497:Temperature: 20.5 C
2025-10-26T00:03:47.355Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T00:04:40.453Z:USER:taskMaster.c:6599:Socket #1: L1N=233.4V L2N=233.8V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T00:13:47.292Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T00:15:38.132Z:USER:taskMaster.c:6497:Temperature: 20.2 C
2025-10-26T00:19:40.355Z:USER:taskMaster.c:6599:Socket #1: L1N=233.6V L2N=234.2V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T00:23:47.226Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.8 24.0 24.0)A
2025-10-26T00:30:38.535Z:USER:taskMaster.c:6497:Temperature: 20.1 C
2025-10-26T00:33:47.164Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.9 24.0 24.0)A
2025-10-26T00:34:40.257Z:USER:taskMaster.c:6599:Socket #1: L1N=233.6V L2N=234.5V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T00:43:29.878Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-26T00:43:30.148Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-26T00:43:38.730Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-26T00:43:38.742Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-26T00:43:47.101Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T00:45:38.988Z:USER:taskMaster.c:6497:Temperature: 19.9 C
2025-10-26T00:49:40.160Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=234.9V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T00:53:47.035Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T01:00:39.441Z:USER:taskMaster.c:6497:Temperature: 20.0 C
2025-10-26T01:03:46.972Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T01:04:40.066Z:USER:taskMaster.c:6599:Socket #1: L1N=234.5V L2N=235.1V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T01:13:46.906Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T01:15:39.894Z:USER:taskMaster.c:6497:Temperature: 19.9 C
2025-10-26T01:19:39.968Z:USER:taskMaster.c:6599:Socket #1: L1N=233.5V L2N=234.0V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T01:23:46.843Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T01:30:40.296Z:USER:taskMaster.c:6497:Temperature: 19.8 C
2025-10-26T01:33:46.777Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T01:34:39.871Z:USER:taskMaster.c:6599:Socket #1: L1N=236.0V L2N=236.8V L3N=236.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T01:43:46.714Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T01:45:40.750Z:USER:taskMaster.c:6497:Temperature: 19.8 C
2025-10-26T01:49:39.777Z:USER:taskMaster.c:6599:Socket #1: L1N=236.0V L2N=236.5V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T01:53:46.648Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T01:54:22.632Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-26T01:54:22.925Z:INFO:taskCANopen.c:1775:Updated object 0x2249, 9 bytes
2025-10-26T02:00:41.503Z:USER:taskMaster.c:6497:Temperature: 19.8 C
2025-10-26T02:03:46.585Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T02:04:39.679Z:USER:taskMaster.c:6599:Socket #1: L1N=235.1V L2N=235.5V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T02:13:46.519Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T02:15:41.707Z:USER:taskMaster.c:6497:Temperature: 19.5 C
2025-10-26T02:19:39.582Z:USER:taskMaster.c:6599:Socket #1: L1N=235.0V L2N=235.2V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T02:23:46.457Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T02:30:42.160Z:USER:taskMaster.c:6497:Temperature: 19.5 C
2025-10-26T02:33:46.441Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T02:34:39.484Z:USER:taskMaster.c:6599:Socket #1: L1N=234.9V L2N=235.3V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T02:43:37.957Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-26T02:43:37.968Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-26T02:43:46.375Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T02:45:42.664Z:USER:taskMaster.c:6497:Temperature: 19.5 C
2025-10-26T02:49:39.386Z:USER:taskMaster.c:6599:Socket #1: L1N=235.4V L2N=235.8V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T02:53:46.312Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T03:00:43.066Z:USER:taskMaster.c:6497:Temperature: 19.5 C
2025-10-26T03:03:46.246Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T03:04:39.292Z:USER:taskMaster.c:6599:Socket #1: L1N=234.3V L2N=234.7V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T03:13:46.183Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T03:15:43.519Z:USER:taskMaster.c:6497:Temperature: 19.6 C
2025-10-26T03:19:39.195Z:USER:taskMaster.c:6599:Socket #1: L1N=233.6V L2N=233.9V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T03:23:46.117Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T03:30:43.972Z:USER:taskMaster.c:6497:Temperature: 19.9 C
2025-10-26T03:33:46.054Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.9 24.0 24.0)A
2025-10-26T03:34:39.097Z:USER:taskMaster.c:6599:Socket #1: L1N=234.3V L2N=234.5V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T03:43:45.988Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T03:45:44.425Z:USER:taskMaster.c:6497:Temperature: 19.9 C
2025-10-26T03:49:39.000Z:USER:taskMaster.c:6599:Socket #1: L1N=234.0V L2N=234.3V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T03:53:45.925Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.6 24.0 24.0)A
2025-10-26T04:00:44.332Z:USER:taskMaster.c:6497:Temperature: 19.9 C
2025-10-26T04:03:45.859Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 24.0 24.0)A
2025-10-26T04:04:38.906Z:USER:taskMaster.c:6599:Socket #1: L1N=232.9V L2N=233.3V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T04:13:45.796Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T04:15:44.285Z:USER:taskMaster.c:6497:Temperature: 19.9 C
2025-10-26T04:19:38.808Z:USER:taskMaster.c:6599:Socket #1: L1N=234.2V L2N=234.7V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T04:23:45.730Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T04:30:44.738Z:USER:taskMaster.c:6497:Temperature: 19.8 C
2025-10-26T04:33:45.667Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T04:34:38.710Z:USER:taskMaster.c:6599:Socket #1: L1N=234.3V L2N=234.5V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T04:43:28.117Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-26T04:43:28.386Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-26T04:43:37.183Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-26T04:43:37.195Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-26T04:43:45.601Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T04:45:45.242Z:USER:taskMaster.c:6497:Temperature: 19.9 C
2025-10-26T04:49:38.613Z:USER:taskMaster.c:6599:Socket #1: L1N=233.5V L2N=233.8V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T04:53:45.539Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T05:00:45.695Z:USER:taskMaster.c:6497:Temperature: 19.8 C
2025-10-26T05:03:45.472Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T05:04:38.519Z:USER:taskMaster.c:6599:Socket #1: L1N=235.9V L2N=236.4V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T05:13:45.410Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T05:15:46.097Z:USER:taskMaster.c:6497:Temperature: 19.9 C
2025-10-26T05:19:38.472Z:USER:taskMaster.c:6599:Socket #1: L1N=235.7V L2N=236.1V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T05:23:45.343Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T05:30:46.550Z:USER:taskMaster.c:6497:Temperature: 19.9 C
2025-10-26T05:33:45.281Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T05:34:38.375Z:USER:taskMaster.c:6599:Socket #1: L1N=235.9V L2N=236.5V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T05:43:45.214Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T05:45:47.003Z:USER:taskMaster.c:6497:Temperature: 20.1 C
2025-10-26T05:49:38.277Z:USER:taskMaster.c:6599:Socket #1: L1N=235.3V L2N=235.8V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T05:53:45.152Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T05:53:49.914Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-10-26T06:00:47.457Z:USER:taskMaster.c:6497:Temperature: 20.1 C
2025-10-26T06:03:45.085Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.9 24.0 24.0)A
2025-10-26T06:03:49.847Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-10-26T06:04:38.183Z:USER:taskMaster.c:6599:Socket #1: L1N=237.7V L2N=238.5V L3N=238.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T06:13:45.023Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-26T06:13:49.882Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-10-26T06:15:47.910Z:USER:taskMaster.c:6497:Temperature: 20.4 C
2025-10-26T06:19:38.085Z:USER:taskMaster.c:6599:Socket #1: L1N=232.2V L2N=233.3V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T06:23:44.960Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-26T06:30:48.363Z:USER:taskMaster.c:6497:Temperature: 20.6 C
2025-10-26T06:33:44.894Z:INFO:active_lb.c:308:SMt:(1.0 1.0 4.0)A Free:(24.0 24.0 21.0)A ALB:(24.0 24.0 21.0)A
2025-10-26T06:34:37.988Z:USER:taskMaster.c:6599:Socket #1: L1N=232.6V L2N=233.8V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T06:43:36.414Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-26T06:43:36.421Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-26T06:43:44.832Z:INFO:active_lb.c:308:SMt:(1.0 1.0 4.0)A Free:(24.0 24.0 21.0)A ALB:(24.0 24.0 21.0)A
2025-10-26T06:45:48.816Z:USER:taskMaster.c:6497:Temperature: 20.6 C
2025-10-26T06:49:37.894Z:USER:taskMaster.c:6599:Socket #1: L1N=233.8V L2N=234.5V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T06:53:44.765Z:INFO:active_lb.c:308:SMt:(1.0 1.0 4.0)A Free:(24.0 24.0 21.0)A ALB:(24.0 24.0 21.0)A
2025-10-26T07:00:49.371Z:USER:taskMaster.c:6497:Temperature: 20.8 C
2025-10-26T07:03:44.703Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-26T07:04:37.796Z:USER:taskMaster.c:6599:Socket #1: L1N=232.2V L2N=232.8V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T07:13:44.636Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-26T07:15:49.726Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-26T07:19:37.699Z:USER:taskMaster.c:6599:Socket #1: L1N=235.6V L2N=235.9V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T07:23:44.574Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-26T07:30:50.179Z:USER:taskMaster.c:6497:Temperature: 21.2 C
2025-10-26T07:33:44.511Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 5.0)A Free:(26.0 24.0 20.0)A ALB:(26.4 24.0 20.0)A
2025-10-26T07:34:37.605Z:USER:taskMaster.c:6599:Socket #1: L1N=237.7V L2N=238.0V L3N=237.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T07:43:44.445Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 5.0)A Free:(26.0 26.0 20.0)A ALB:(26.0 26.0 20.0)A
2025-10-26T07:45:50.582Z:USER:taskMaster.c:6497:Temperature: 21.9 C
2025-10-26T07:49:37.507Z:USER:taskMaster.c:6599:Socket #1: L1N=235.0V L2N=234.6V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T07:53:44.382Z:INFO:active_lb.c:308:SMt:(-1.0 6.0 5.0)A Free:(26.0 19.0 20.0)A ALB:(25.9 19.0 20.0)A
2025-10-26T08:00:50.988Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-26T08:03:44.320Z:INFO:active_lb.c:308:SMt:(-1.0 6.0 5.0)A Free:(26.0 19.0 20.0)A ALB:(26.0 19.0 19.9)A
2025-10-26T08:04:37.414Z:USER:taskMaster.c:6599:Socket #1: L1N=237.5V L2N=235.3V L3N=237.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T08:13:44.253Z:INFO:active_lb.c:308:SMt:(-1.0 6.0 5.0)A Free:(26.0 19.0 20.0)A ALB:(25.7 19.0 20.0)A
2025-10-26T08:15:51.492Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-26T08:19:37.316Z:USER:taskMaster.c:6599:Socket #1: L1N=236.9V L2N=236.1V L3N=236.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T08:23:44.191Z:INFO:active_lb.c:308:SMt:(2.0 6.0 1.0)A Free:(23.0 19.0 24.0)A ALB:(23.2 19.0 24.0)A
2025-10-26T08:30:51.843Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-26T08:33:44.128Z:INFO:active_lb.c:308:SMt:(1.0 5.0 1.0)A Free:(24.0 20.0 24.0)A ALB:(26.0 20.0 24.0)A
2025-10-26T08:34:37.222Z:USER:taskMaster.c:6599:Socket #1: L1N=236.3V L2N=236.2V L3N=237.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T08:43:26.371Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-26T08:43:26.640Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-26T08:43:35.644Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-26T08:43:35.656Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-26T08:43:44.062Z:INFO:active_lb.c:308:SMt:(-1.0 14.0 1.0)A Free:(26.0 11.0 24.0)A ALB:(26.0 12.2 24.0)A
2025-10-26T08:43:44.113Z:INFO:comFaults.c:482:Reset fault status
2025-10-26T08:43:45.800Z:COM:ocpp_rpc.c:715:-> [2,"31","Heartbeat",{}]
2025-10-26T08:43:45.835Z:COM:ocpp_rpc.c:1292:<- [3,"31",{"currentTime":"2025-10-26T08:43:51.542Z"}]
2025-10-26T08:43:51.000Z:SECURITY:taskTime.c:603:Time changed
2025-10-26T08:45:57.703Z:USER:taskMaster.c:6497:Temperature: 22.5 C
2025-10-26T08:49:42.277Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=234.0V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T08:53:49.152Z:INFO:active_lb.c:308:SMt:(3.0 5.0 1.0)A Free:(22.0 20.0 24.0)A ALB:(22.0 20.4 23.7)A
2025-10-26T09:00:57.757Z:USER:taskMaster.c:6497:Temperature: 22.8 C
2025-10-26T09:03:49.089Z:INFO:active_lb.c:308:SMt:(6.0 5.0 1.0)A Free:(19.0 20.0 24.0)A ALB:(27.0 20.0 24.0)A
2025-10-26T09:04:42.183Z:USER:taskMaster.c:6599:Socket #1: L1N=236.9V L2N=235.2V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T09:13:49.027Z:INFO:active_lb.c:308:SMt:(2.0 -1.0 1.0)A Free:(23.0 26.0 24.0)A ALB:(24.3 25.9 24.0)A
2025-10-26T09:15:58.210Z:USER:taskMaster.c:6497:Temperature: 23.0 C
2025-10-26T09:19:42.089Z:USER:taskMaster.c:6599:Socket #1: L1N=233.9V L2N=232.0V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T09:23:48.960Z:INFO:active_lb.c:308:SMt:(-2.0 9.0 1.0)A Free:(27.0 16.0 24.0)A ALB:(27.0 18.0 24.0)A
2025-10-26T09:30:58.667Z:USER:taskMaster.c:6497:Temperature: 23.4 C
2025-10-26T09:33:48.898Z:INFO:active_lb.c:308:SMt:(-1.0 8.0 1.0)A Free:(26.0 17.0 24.0)A ALB:(25.8 22.0 23.6)A
2025-10-26T09:34:41.992Z:USER:taskMaster.c:6599:Socket #1: L1N=235.1V L2N=234.4V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T09:43:48.835Z:INFO:active_lb.c:308:SMt:(7.0 1.0 2.0)A Free:(18.0 24.0 23.0)A ALB:(18.1 23.6 23.1)A
2025-10-26T09:45:59.070Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-26T09:49:41.898Z:USER:taskMaster.c:6599:Socket #1: L1N=235.8V L2N=235.2V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T09:53:48.769Z:INFO:active_lb.c:308:SMt:(6.0 1.0 1.0)A Free:(19.0 24.0 24.0)A ALB:(18.6 22.9 24.0)A
2025-10-26T10:00:59.476Z:USER:taskMaster.c:6497:Temperature: 23.0 C
2025-10-26T10:03:48.707Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(25.8 23.0 24.0)A
2025-10-26T10:04:41.800Z:USER:taskMaster.c:6599:Socket #1: L1N=233.2V L2N=233.6V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T10:13:48.644Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 1.0)A Free:(26.0 27.0 24.0)A ALB:(26.0 26.9 24.0)A
2025-10-26T10:15:59.980Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-26T10:19:41.707Z:USER:taskMaster.c:6599:Socket #1: L1N=233.8V L2N=233.8V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T10:23:48.582Z:INFO:active_lb.c:308:SMt:(8.0 5.0 1.0)A Free:(17.0 20.0 24.0)A ALB:(17.2 19.9 24.0)A
2025-10-26T10:31:00.386Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-26T10:33:48.515Z:INFO:active_lb.c:308:SMt:(-1.0 4.0 1.0)A Free:(26.0 21.0 24.0)A ALB:(26.0 20.7 23.9)A
2025-10-26T10:34:41.609Z:USER:taskMaster.c:6599:Socket #1: L1N=237.6V L2N=235.9V L3N=236.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T10:43:40.035Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-26T10:43:40.046Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-26T10:43:48.453Z:INFO:active_lb.c:308:SMt:(-2.0 -3.0 2.0)A Free:(27.0 28.0 23.0)A ALB:(27.0 27.7 23.0)A
2025-10-26T10:46:01.039Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-26T10:49:41.515Z:USER:taskMaster.c:6599:Socket #1: L1N=239.2V L2N=238.2V L3N=238.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T10:53:48.390Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T11:01:01.292Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-26T11:03:48.324Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-26T11:04:41.421Z:USER:taskMaster.c:6599:Socket #1: L1N=232.0V L2N=231.8V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T11:13:48.261Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.2 22.7 24.0)A
2025-10-26T11:16:01.898Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-26T11:19:41.324Z:USER:taskMaster.c:6599:Socket #1: L1N=232.6V L2N=233.6V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T11:23:48.199Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-26T11:31:02.152Z:USER:taskMaster.c:6497:Temperature: 23.0 C
2025-10-26T11:33:48.132Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-26T11:34:41.230Z:USER:taskMaster.c:6599:Socket #1: L1N=232.8V L2N=234.1V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T11:43:48.070Z:INFO:active_lb.c:308:SMt:(-1.0 3.0 1.0)A Free:(26.0 22.0 24.0)A ALB:(26.0 22.5 24.0)A
2025-10-26T11:46:03.007Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-26T11:49:41.132Z:USER:taskMaster.c:6599:Socket #1: L1N=235.9V L2N=236.1V L3N=237.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T11:53:48.007Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.4 22.1 24.0)A
2025-10-26T12:01:03.410Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-26T12:03:47.945Z:INFO:active_lb.c:308:SMt:(-1.0 3.0 1.0)A Free:(26.0 22.0 24.0)A ALB:(26.0 22.0 24.0)A
2025-10-26T12:04:41.039Z:USER:taskMaster.c:6599:Socket #1: L1N=231.9V L2N=232.0V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T12:13:47.878Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 21.4 24.0)A
2025-10-26T12:16:03.664Z:USER:taskMaster.c:6497:Temperature: 22.5 C
2025-10-26T12:19:40.941Z:USER:taskMaster.c:6599:Socket #1: L1N=235.6V L2N=234.9V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T12:23:47.816Z:INFO:active_lb.c:308:SMt:(-1.0 4.0 1.0)A Free:(26.0 21.0 24.0)A ALB:(25.6 21.4 24.0)A
2025-10-26T12:31:03.871Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-26T12:33:47.753Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(24.0 21.0 24.0)A ALB:(24.2 21.0 24.0)A
2025-10-26T12:34:40.847Z:USER:taskMaster.c:6599:Socket #1: L1N=229.9V L2N=230.4V L3N=230.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T12:43:29.812Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-26T12:43:30.082Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-26T12:43:39.269Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-26T12:43:39.281Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-26T12:43:47.687Z:INFO:active_lb.c:308:SMt:(-1.0 4.0 1.0)A Free:(26.0 21.0 24.0)A ALB:(24.0 21.0 24.0)A
2025-10-26T12:46:04.472Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-26T12:49:40.750Z:USER:taskMaster.c:6599:Socket #1: L1N=236.2V L2N=236.6V L3N=235.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T12:53:47.625Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(25.2 24.0 24.0)A
2025-10-26T13:01:04.730Z:USER:taskMaster.c:6497:Temperature: 22.6 C
2025-10-26T13:03:47.562Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(26.0 22.0 24.0)A
2025-10-26T13:04:40.656Z:USER:taskMaster.c:6599:Socket #1: L1N=233.3V L2N=232.9V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T13:13:47.496Z:INFO:active_lb.c:308:SMt:(-1.0 3.0 1.0)A Free:(26.0 22.0 24.0)A ALB:(26.0 22.0 24.0)A
2025-10-26T13:16:05.234Z:USER:taskMaster.c:6497:Temperature: 22.8 C
2025-10-26T13:19:40.562Z:USER:taskMaster.c:6599:Socket #1: L1N=234.2V L2N=232.9V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T13:23:47.433Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 1.0)A Free:(26.0 23.0 24.0)A ALB:(26.0 23.0 24.0)A
2025-10-26T13:31:05.636Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-26T13:33:47.371Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.4 26.3 24.0)A
2025-10-26T13:34:40.464Z:USER:taskMaster.c:6599:Socket #1: L1N=237.3V L2N=237.5V L3N=238.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T13:43:47.304Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(27.0 27.0 24.0)A ALB:(27.0 27.0 24.0)A
2025-10-26T13:46:06.093Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-26T13:49:40.371Z:USER:taskMaster.c:6599:Socket #1: L1N=236.0V L2N=236.3V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T13:53:47.242Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 1.0)A Free:(26.0 27.0 24.0)A ALB:(26.0 27.0 24.0)A
2025-10-26T14:01:06.546Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-26T14:03:47.179Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 24.9 24.0)A
2025-10-26T14:04:40.273Z:USER:taskMaster.c:6599:Socket #1: L1N=232.3V L2N=232.0V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T14:13:47.117Z:INFO:active_lb.c:308:SMt:(-2.0 1.0 1.0)A Free:(27.0 24.0 24.0)A ALB:(26.6 24.5 24.0)A
2025-10-26T14:16:06.949Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-26T14:19:40.179Z:USER:taskMaster.c:6599:Socket #1: L1N=234.6V L2N=234.6V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T14:22:23.847Z:INFO:taskMain.c:6230:Socket #1: Active current 0.0->16.0 due to current limit: Connector-MaxCurrent,
2025-10-26T14:22:23.847Z:INFO:taskMain.c:6230:Simplified-Mode3, ChargingProfile, Start
2025-10-26T14:22:23.910Z:INFO:taskMaster.c:4875:Socket #1: state main : CABLE_CONNECTED
2025-10-26T14:22:23.921Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_A
2025-10-26T14:22:23.929Z:INFO:taskMaster.c:4897:Socket #1: state led : CABLE_CONNECTED
2025-10-26T14:22:23.937Z:COM:ocpp_rpc.c:715:-> [2,"34","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-26T14:22:23.937Z:COM:ocpp_rpc.c:715:"Preparing"}]
2025-10-26T14:22:23.972Z:COM:ocpp_rpc.c:1292:<- [3,"34",{}]
2025-10-26T14:22:24.328Z:INFO:taskMain.c:6730:Socket #1: CPhigh 9.3 V
2025-10-26T14:22:24.335Z:INFO:taskMain.c:6735:Socket #1: CPlow 9.3 V
2025-10-26T14:22:24.343Z:INFO:taskMain.c:6740:Socket #1: PP 700 Ohm (20 A)
2025-10-26T14:22:24.925Z:INFO:taskMain.c:1426:Socket #1: main state: CABLE_CONNECTED, CP: 9.3/0.9, no tag
2025-10-26T14:22:25.910Z:INFO:taskMaster.c:4875:Socket #1: state main : EV_CONNECTED_UNAUTHORIZED
2025-10-26T14:22:25.921Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B1
2025-10-26T14:22:26.937Z:INFO:taskMain.c:1426:Socket #1: main state: EV_CONNECTED_UNAUTHORIZED, CP: 9.3/0.9, no tag
2025-10-26T14:22:30.011Z:USER:tag.c:1620:Reader 0 Got NFC tag: 04BB29EAFD0F94
2025-10-26T14:22:30.027Z:COM:ocpp_rpc.c:715:-> [2,"35","StatusNotification",{"connectorId":0,"errorCode":"NoError","info":"I
2025-10-26T14:22:30.027Z:COM:ocpp_rpc.c:715:nfo: Charge card 04BB29EAFD0F94 detected","status":"Available"}]
2025-10-26T14:22:30.070Z:COM:ocpp_rpc.c:1292:<- [3,"35",{}]
2025-10-26T14:22:30.210Z:USER:taskMaster.c:6846:Socket #1: has reliable metervalue
2025-10-26T14:22:30.218Z:INFO:taskMaster.c:1571:1 cables attached
2025-10-26T14:22:30.257Z:INFO:taskMaster.c:4897:Socket #1: state led : AUTHORISING
2025-10-26T14:22:30.273Z:USER:tag.c:584:Tag 04BB29EAFD0F94 is authorised by white list
2025-10-26T14:22:30.308Z:USER:taskMaster.c:6846:Socket #1: has reliable metervalue
2025-10-26T14:22:30.320Z:USER:taskMaster.c:1872:Preparing 1, with cable 1
2025-10-26T14:22:30.355Z:USER:board_ng9xx.c:5059:Socket #1: lock socket motor
2025-10-26T14:22:30.363Z:INFO:taskMaster.c:4875:Socket #1: state main : EV_CONNECTED_AUTHORIZED
2025-10-26T14:22:31.273Z:INFO:taskMaster.c:7412:New charging session started, metervalue=5502075.000
2025-10-26T14:22:31.289Z:INFO:db_transaction.c:16:Added TransactionStart for socket 1 at 0x000b7aa8 (ts: 2025-10-26 14:22:30)
2025-10-26T14:22:31.312Z:INFO:taskMaster.c:4897:Socket #1: state led : EV_CONNECTED
2025-10-26T14:22:31.320Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-26T14:22:31.367Z:INFO:taskMain.c:1424:Socket #1: main state: EV_CONNECTED_AUTHORIZED, CP: 9.3/9.3, tag: 04BB29EAFD0F94
2025-10-26T14:22:31.382Z:INFO:taskMaster.c:6271:Socket #1: external current limit 15.9 A until 2025-10-26T23:00:00Z
2025-10-26T14:22:31.394Z:USER:taskMaster.c:6318:Socket #1: external current limit 15.9 A
2025-10-26T14:22:31.406Z:INFO:taskMain.c:6230:Socket #1: Active current 16.0->15.9 due to current limit: ChargingProfile
2025-10-26T14:22:31.457Z:INFO:taskMain.c:943:Socket #1: charging session status set active
2025-10-26T14:22:31.464Z:INFO:taskMaster.c:4875:Socket #1: state main : WAIT_FOR_START_METERVALUE
2025-10-26T14:22:31.476Z:INFO:taskMaster.c:4897:Socket #1: state led : CHARGING_PREPARING
2025-10-26T14:22:32.566Z:INFO:taskMain.c:1424:Socket #1: main state: WAIT_FOR_START_METERVALUE, CP: 9.3/9.3, tag: 04BB29EAFD0F
2025-10-26T14:22:32.566Z:INFO:taskMain.c:1424:94
2025-10-26T14:22:34.507Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_PRE_POWER_OFF
2025-10-26T14:22:34.558Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_OFF
2025-10-26T14:22:34.570Z:INFO:taskMaster.c:4897:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-10-26T14:22:34.578Z:COM:ocpp_rpc.c:715:-> [2,"36","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-26T14:22:34.578Z:COM:ocpp_rpc.c:715:"SuspendedEVSE"}]
2025-10-26T14:22:34.617Z:COM:ocpp_rpc.c:1292:<- [3,"36",{}]
2025-10-26T14:22:34.660Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B2
2025-10-26T14:22:35.558Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_ON
2025-10-26T14:22:35.570Z:INFO:taskMaster.c:6553:Start logging meter values @30s.
2025-10-26T14:22:35.578Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=234.4V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T14:22:35.589Z:INFO:taskMain.c:6730:Socket #1: CPhigh 6.3 V
2025-10-26T14:22:35.597Z:INFO:taskMain.c:6735:Socket #1: CPlow -11.4 V
2025-10-26T14:22:35.605Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-26T14:22:35.617Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_ON_BYPASS_ON
2025-10-26T14:22:35.625Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_C2
2025-10-26T14:22:35.636Z:INFO:taskMaster.c:4897:Socket #1: state led : CHARGING_POWER_ON
2025-10-26T14:22:35.644Z:COM:ocpp_rpc.c:715:-> [2,"37","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-26T14:22:35.644Z:COM:ocpp_rpc.c:715:"Charging"}]
2025-10-26T14:22:35.667Z:COM:ocpp_rpc.c:1292:<- [3,"37",{}]
2025-10-26T14:22:36.566Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-10-26T14:22:41.410Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-26T14:22:41.421Z:INFO:db_chargingprofi:26: socket 0
2025-10-26T14:22:41.429Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-26T14:22:41.437Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-26T14:22:41.445Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-26T14:22:41.453Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-26T14:22:41.464Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-26T14:22:41.472Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-26T14:22:41.480Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-26T14:22:41.488Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-26T14:22:41.496Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-26T14:22:41.503Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-26T14:22:41.511Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-26T14:22:41.523Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-26T14:22:41.531Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-26T14:22:41.539Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-26T14:22:41.546Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-26T14:22:41.554Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-26T14:22:41.566Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-26T14:22:41.574Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-26T14:22:41.582Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-26T14:22:41.589Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-26T14:22:41.597Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-26T14:23:05.656Z:USER:taskMaster.c:6599:Socket #1: L1N=232.4V L2N=231.9V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T14:23:05.667Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-26T14:23:35.550Z:INFO:taskMain.c:6798:Socket #1: reset HF switch count 1
2025-10-26T14:23:35.652Z:USER:taskMaster.c:6599:Socket #1: L1N=232.1V L2N=232.1V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T14:23:35.664Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.9mA
2025-10-26T14:23:47.050Z:INFO:active_lb.c:308:SMt:(15.0 16.0 16.0)A Free:(10.0 9.0 9.0)A ALB:(26.8 25.2 25.7)A
2025-10-26T14:24:05.648Z:USER:taskMaster.c:6599:Socket #1: L1N=232.7V L2N=232.2V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T14:24:05.660Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-26T14:24:35.648Z:USER:taskMaster.c:6599:Socket #1: L1N=233.1V L2N=232.7V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T14:24:35.660Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-10-26T14:25:05.644Z:USER:taskMaster.c:6599:Socket #1: L1N=232.9V L2N=231.8V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T14:25:05.656Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-26T14:25:06.042Z:INFO:EVCapabilities.c:24:Socket #1 EV: #phases supported: 3
2025-10-26T14:25:35.640Z:USER:taskMaster.c:6599:Socket #1: L1N=232.6V L2N=231.8V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T14:25:35.652Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-26T14:26:05.636Z:USER:taskMaster.c:6599:Socket #1: L1N=232.2V L2N=231.3V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T14:26:05.648Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-26T14:26:35.632Z:USER:taskMaster.c:6599:Socket #1: L1N=231.5V L2N=230.7V L3N=231.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T14:26:35.644Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.7kW Idc=0.8mA
2025-10-26T14:27:05.628Z:USER:taskMaster.c:6599:Socket #1: L1N=231.4V L2N=230.5V L3N=231.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T14:27:05.644Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-26T14:27:35.628Z:USER:taskMaster.c:6599:Socket #1: L1N=230.6V L2N=230.9V L3N=230.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T14:27:35.640Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.5A I3=15.4A P=10.7kW Idc=0.7mA
2025-10-26T14:27:35.652Z:INFO:taskMaster.c:6541:Stop logging meter values @30s.
2025-10-26T14:31:06.855Z:USER:taskMaster.c:6497:Temperature: 25.0 C
2025-10-26T14:33:46.988Z:INFO:active_lb.c:308:SMt:(17.0 18.0 16.0)A Free:(8.0 7.0 9.0)A ALB:(23.7 22.6 24.6)A
2025-10-26T14:37:31.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-26T14:42:35.531Z:USER:taskMaster.c:6599:Socket #1: L1N=234.5V L2N=234.6V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T14:42:35.542Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-10-26T14:43:38.507Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-26T14:43:38.519Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-26T14:43:46.925Z:INFO:active_lb.c:308:SMt:(18.0 17.0 16.0)A Free:(7.0 8.0 9.0)A ALB:(22.5 23.2 24.5)A
2025-10-26T14:46:07.210Z:USER:taskMaster.c:6497:Temperature: 27.9 C
2025-10-26T14:52:31.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-26T14:53:46.863Z:INFO:active_lb.c:308:SMt:(16.0 17.0 16.0)A Free:(9.0 8.0 9.0)A ALB:(24.9 23.4 24.5)A
2025-10-26T14:57:35.437Z:USER:taskMaster.c:6599:Socket #1: L1N=230.4V L2N=230.3V L3N=230.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T14:57:35.449Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.7kW Idc=0.7mA
2025-10-26T15:01:07.617Z:USER:taskMaster.c:6497:Temperature: 29.9 C
2025-10-26T15:01:41.417Z:INFO:taskMain.c:6230:Socket #1: Active current 15.9->14.5 due to current limit: Active-LoadBalancing
2025-10-26T15:01:41.429Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->24.2)
2025-10-26T15:01:41.460Z:INFO:taskMaster.c:4897:Socket #1: state led : LOADBALANCING_LIMITED
2025-10-26T15:01:41.539Z:INFO:taskMain.c:6746:Socket #1: PWM DC 24.2% (14.5 A)
2025-10-26T15:01:53.417Z:INFO:taskMain.c:6230:Socket #1: Active current 14.5->12.8 due to current limit: Active-LoadBalancing
2025-10-26T15:01:53.429Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->21.3)
2025-10-26T15:01:53.656Z:INFO:taskMain.c:6746:Socket #1: PWM DC 21.3% (12.8 A)
2025-10-26T15:02:05.417Z:INFO:taskMain.c:6230:Socket #1: Active current 12.8->11.4 due to current limit: Active-LoadBalancing
2025-10-26T15:02:05.429Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (21.3->19.0)
2025-10-26T15:02:05.777Z:INFO:taskMain.c:6746:Socket #1: PWM DC 19.0% (11.4 A)
2025-10-26T15:02:17.414Z:INFO:taskMain.c:6230:Socket #1: Active current 11.4->10.1 due to current limit: Active-LoadBalancing
2025-10-26T15:02:17.425Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->16.8)
2025-10-26T15:02:17.894Z:INFO:taskMain.c:6746:Socket #1: PWM DC 16.8% (10.1 A)
2025-10-26T15:02:29.414Z:INFO:taskMain.c:6230:Socket #1: Active current 10.1->9.5 due to current limit: Active-LoadBalancing
2025-10-26T15:02:29.425Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (16.8->15.9)
2025-10-26T15:02:30.011Z:INFO:taskMain.c:6746:Socket #1: PWM DC 15.9% (9.5 A)
2025-10-26T15:02:41.414Z:INFO:taskMain.c:6230:Socket #1: Active current 9.5->10.2 due to current limit: Active-LoadBalancing
2025-10-26T15:02:42.132Z:INFO:taskMain.c:6746:Socket #1: PWM DC 17.0% (10.2 A)
2025-10-26T15:02:53.410Z:INFO:taskMain.c:6230:Socket #1: Active current 10.2->11.3 due to current limit: Active-LoadBalancing
2025-10-26T15:02:54.250Z:INFO:taskMain.c:6746:Socket #1: PWM DC 18.7% (11.2 A)
2025-10-26T15:03:05.410Z:INFO:taskMain.c:6230:Socket #1: Active current 11.3->11.9 due to current limit: Active-LoadBalancing
2025-10-26T15:03:06.371Z:INFO:taskMain.c:6746:Socket #1: PWM DC 19.8% (11.9 A)
2025-10-26T15:03:17.410Z:INFO:taskMain.c:6230:Socket #1: Active current 11.9->15.9 due to current limit: ChargingProfile
2025-10-26T15:03:17.453Z:INFO:taskMaster.c:4897:Socket #1: state led : CHARGING_POWER_ON
2025-10-26T15:03:17.476Z:INFO:taskMain.c:6746:Socket #1: PWM DC 26.5% (15.9 A)
2025-10-26T15:03:46.796Z:INFO:active_lb.c:308:SMt:(18.0 17.0 31.0)A Free:(7.0 8.0 -6.0)A ALB:(24.7 22.2 19.5)A
2025-10-26T15:04:05.402Z:INFO:taskMain.c:6230:Socket #1: Active current 15.9->13.8 due to current limit: Active-LoadBalancing
2025-10-26T15:04:05.417Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->22.9)
2025-10-26T15:04:05.445Z:INFO:taskMaster.c:4897:Socket #1: state led : LOADBALANCING_LIMITED
2025-10-26T15:04:05.953Z:INFO:taskMain.c:6746:Socket #1: PWM DC 22.9% (13.7 A)
2025-10-26T15:04:17.402Z:INFO:taskMain.c:6230:Socket #1: Active current 13.8->10.0 due to current limit: Active-LoadBalancing
2025-10-26T15:04:17.414Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (22.9->16.6)
2025-10-26T15:04:18.070Z:INFO:taskMain.c:6746:Socket #1: PWM DC 16.6% (10.0 A)
2025-10-26T15:04:29.402Z:INFO:taskMain.c:6230:Socket #1: Active current 10.0->6.2 due to current limit: Active-LoadBalancing
2025-10-26T15:04:29.414Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (16.6->10.3)
2025-10-26T15:04:30.191Z:INFO:taskMain.c:6746:Socket #1: PWM DC 10.3% (6.2 A)
2025-10-26T15:04:41.398Z:INFO:taskMain.c:6230:Socket #1: Active current 6.2->4.9 due to current limit: Active-LoadBalancing
2025-10-26T15:04:41.410Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (10.3->10.3)
2025-10-26T15:04:41.425Z:WARNING:taskMain.c:4848:Socket #1: maximum current(4.88) < minimum current(6.00)
2025-10-26T15:04:41.441Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-10-26T15:04:41.453Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_C1
2025-10-26T15:04:41.460Z:INFO:taskMaster.c:4897:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-10-26T15:04:41.472Z:COM:ocpp_rpc.c:715:-> [2,"38","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-26T15:04:41.472Z:COM:ocpp_rpc.c:715:"SuspendedEVSE"}]
2025-10-26T15:04:41.503Z:COM:ocpp_rpc.c:1292:<- [3,"38",{}]
2025-10-26T15:04:42.308Z:INFO:taskMain.c:6735:Socket #1: CPlow 6.3 V
2025-10-26T15:04:42.449Z:INFO:taskMain.c:6730:Socket #1: CPhigh 9.2 V
2025-10-26T15:04:42.457Z:INFO:taskMain.c:6735:Socket #1: CPlow 9.2 V
2025-10-26T15:04:42.464Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.2/9.2, tag: 04BB
2025-10-26T15:04:42.464Z:INFO:taskMain.c:1424:29EAFD0F94
2025-10-26T15:04:46.492Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_OFF_BYPASS_OFF
2025-10-26T15:04:46.503Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B1
2025-10-26T15:04:53.398Z:INFO:taskMain.c:6230:Socket #1: Active current 4.9->3.3 due to current limit: Active-LoadBalancing
2025-10-26T15:05:05.398Z:INFO:taskMain.c:6230:Socket #1: Active current 3.3->4.4 due to current limit: Active-LoadBalancing
2025-10-26T15:05:17.394Z:INFO:taskMain.c:6230:Socket #1: Active current 4.4->5.0 due to current limit: Active-LoadBalancing
2025-10-26T15:05:29.394Z:INFO:taskMain.c:6230:Socket #1: Active current 5.0->5.4 due to current limit: Active-LoadBalancing
2025-10-26T15:05:41.394Z:INFO:taskMain.c:6230:Socket #1: Active current 5.4->5.7 due to current limit: Active-LoadBalancing
2025-10-26T15:05:53.390Z:INFO:taskMain.c:6230:Socket #1: Active current 5.7->5.8 due to current limit: Active-LoadBalancing
2025-10-26T15:06:05.390Z:INFO:taskMain.c:6230:Socket #1: Active current 5.8->6.3 due to current limit: Active-LoadBalancing
2025-10-26T15:06:05.433Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_OFF
2025-10-26T15:06:05.445Z:INFO:taskMaster.c:4897:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-10-26T15:06:05.535Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B2
2025-10-26T15:06:06.269Z:INFO:taskMain.c:6735:Socket #1: CPlow -11.4 V
2025-10-26T15:06:06.484Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_ON
2025-10-26T15:06:06.492Z:INFO:taskMaster.c:6553:Start logging meter values @30s.
2025-10-26T15:06:06.503Z:USER:taskMaster.c:6599:Socket #1: L1N=235.3V L2N=234.3V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:06:06.515Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-26T15:06:06.523Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_ON_BYPASS_ON
2025-10-26T15:06:06.535Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_C2
2025-10-26T15:06:06.542Z:INFO:taskMaster.c:4897:Socket #1: state led : LOADBALANCING_LIMITED
2025-10-26T15:06:06.554Z:COM:ocpp_rpc.c:715:-> [2,"39","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-26T15:06:06.554Z:COM:ocpp_rpc.c:715:"Charging"}]
2025-10-26T15:06:06.578Z:COM:ocpp_rpc.c:1292:<- [3,"39",{}]
2025-10-26T15:06:07.281Z:INFO:taskMain.c:6730:Socket #1: CPhigh 6.2 V
2025-10-26T15:06:07.480Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-10-26T15:06:17.390Z:INFO:taskMain.c:6230:Socket #1: Active current 6.3->8.5 due to current limit: Active-LoadBalancing
2025-10-26T15:06:17.578Z:INFO:taskMain.c:6746:Socket #1: PWM DC 14.2% (8.5 A)
2025-10-26T15:06:29.386Z:INFO:taskMain.c:6230:Socket #1: Active current 8.5->10.8 due to current limit: Active-LoadBalancing
2025-10-26T15:06:29.699Z:INFO:taskMain.c:6746:Socket #1: PWM DC 17.9% (10.7 A)
2025-10-26T15:06:36.531Z:USER:taskMaster.c:6599:Socket #1: L1N=234.6V L2N=233.7V L3N=231.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:06:36.542Z:USER:taskMaster.c:6635:Socket #1: I1=10.4A I2=10.4A I3=10.4A P=7.3kW Idc=0.7mA
2025-10-26T15:06:41.386Z:INFO:taskMain.c:6230:Socket #1: Active current 10.8->9.8 due to current limit: Active-LoadBalancing
2025-10-26T15:06:41.398Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (17.9->16.3)
2025-10-26T15:06:41.816Z:INFO:taskMain.c:6746:Socket #1: PWM DC 16.3% (9.8 A)
2025-10-26T15:06:53.386Z:INFO:taskMain.c:6230:Socket #1: Active current 9.8->8.0 due to current limit: Active-LoadBalancing
2025-10-26T15:06:53.398Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (16.3->13.3)
2025-10-26T15:06:53.937Z:INFO:taskMain.c:6746:Socket #1: PWM DC 13.3% (8.0 A)
2025-10-26T15:07:05.382Z:INFO:taskMain.c:6230:Socket #1: Active current 8.0->6.6 due to current limit: Active-LoadBalancing
2025-10-26T15:07:05.398Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (13.3->11.0)
2025-10-26T15:07:06.054Z:INFO:taskMain.c:6746:Socket #1: PWM DC 11.0% (6.6 A)
2025-10-26T15:07:06.464Z:INFO:taskMain.c:6798:Socket #1: reset HF switch count 1
2025-10-26T15:07:06.527Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=234.2V L3N=231.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:07:06.539Z:USER:taskMaster.c:6635:Socket #1: I1=7.5A I2=7.6A I3=7.6A P=5.3kW Idc=0.7mA
2025-10-26T15:07:17.382Z:INFO:taskMain.c:6230:Socket #1: Active current 6.6->5.3 due to current limit: Active-LoadBalancing
2025-10-26T15:07:17.394Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (11.0->11.0)
2025-10-26T15:07:17.406Z:WARNING:taskMain.c:4848:Socket #1: maximum current(5.29) < minimum current(6.00)
2025-10-26T15:07:17.425Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-10-26T15:07:17.437Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_C1
2025-10-26T15:07:17.445Z:INFO:taskMaster.c:4897:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-10-26T15:07:17.457Z:COM:ocpp_rpc.c:715:-> [2,"40","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-26T15:07:17.457Z:COM:ocpp_rpc.c:715:"SuspendedEVSE"}]
2025-10-26T15:07:17.484Z:COM:ocpp_rpc.c:1292:<- [3,"40",{}]
2025-10-26T15:07:18.171Z:INFO:taskMain.c:6735:Socket #1: CPlow 6.3 V
2025-10-26T15:07:18.433Z:INFO:taskMain.c:6730:Socket #1: CPhigh 9.2 V
2025-10-26T15:07:18.441Z:INFO:taskMain.c:6735:Socket #1: CPlow 9.3 V
2025-10-26T15:07:18.449Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.2/9.3, tag: 04BB
2025-10-26T15:07:18.449Z:INFO:taskMain.c:1424:29EAFD0F94
2025-10-26T15:07:22.476Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_OFF_BYPASS_OFF
2025-10-26T15:07:22.484Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B1
2025-10-26T15:07:29.382Z:INFO:taskMain.c:6230:Socket #1: Active current 5.3->2.8 due to current limit: Active-LoadBalancing
2025-10-26T15:07:31.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-26T15:07:36.523Z:USER:taskMaster.c:6599:Socket #1: L1N=235.4V L2N=234.8V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:07:36.535Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-26T15:07:41.378Z:INFO:taskMain.c:6230:Socket #1: Active current 2.8->4.5 due to current limit: Active-LoadBalancing
2025-10-26T15:07:53.378Z:INFO:taskMain.c:6230:Socket #1: Active current 4.5->5.5 due to current limit: Active-LoadBalancing
2025-10-26T15:08:05.378Z:INFO:taskMain.c:6230:Socket #1: Active current 5.5->6.1 due to current limit: Active-LoadBalancing
2025-10-26T15:08:05.421Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_OFF
2025-10-26T15:08:05.429Z:INFO:taskMaster.c:4897:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-10-26T15:08:05.519Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B2
2025-10-26T15:08:05.898Z:INFO:taskMain.c:6735:Socket #1: CPlow -11.4 V
2025-10-26T15:08:05.906Z:INFO:taskMain.c:6746:Socket #1: PWM DC 10.1% (6.1 A)
2025-10-26T15:08:06.371Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_ON
2025-10-26T15:08:06.378Z:INFO:taskMaster.c:6553:Start logging meter values @30s.
2025-10-26T15:08:06.390Z:USER:taskMaster.c:6599:Socket #1: L1N=235.1V L2N=234.2V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:08:06.402Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-26T15:08:06.410Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_ON_BYPASS_ON
2025-10-26T15:08:06.421Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_C2
2025-10-26T15:08:06.429Z:INFO:taskMaster.c:4897:Socket #1: state led : LOADBALANCING_LIMITED
2025-10-26T15:08:06.441Z:COM:ocpp_rpc.c:715:-> [2,"41","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-26T15:08:06.441Z:COM:ocpp_rpc.c:715:"Charging"}]
2025-10-26T15:08:06.460Z:COM:ocpp_rpc.c:1292:<- [3,"41",{}]
2025-10-26T15:08:06.906Z:INFO:taskMain.c:6730:Socket #1: CPhigh 6.3 V
2025-10-26T15:08:07.386Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-10-26T15:08:17.375Z:INFO:taskMain.c:6230:Socket #1: Active current 6.1->8.8 due to current limit: Active-LoadBalancing
2025-10-26T15:08:17.488Z:INFO:taskMain.c:6746:Socket #1: PWM DC 14.6% (8.8 A)
2025-10-26T15:08:29.375Z:INFO:taskMain.c:6230:Socket #1: Active current 8.8->11.4 due to current limit: Active-LoadBalancing
2025-10-26T15:08:29.605Z:INFO:taskMain.c:6746:Socket #1: PWM DC 19.0% (11.4 A)
2025-10-26T15:08:36.417Z:USER:taskMaster.c:6599:Socket #1: L1N=234.2V L2N=233.7V L3N=231.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:08:36.429Z:USER:taskMaster.c:6635:Socket #1: I1=11.1A I2=11.1A I3=11.1A P=7.8kW Idc=0.7mA
2025-10-26T15:08:41.375Z:INFO:taskMain.c:6230:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-10-26T15:08:53.371Z:INFO:taskMain.c:6230:Socket #1: Active current 11.7->9.9 due to current limit: Active-LoadBalancing
2025-10-26T15:08:53.386Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->16.4)
2025-10-26T15:08:53.843Z:INFO:taskMain.c:6746:Socket #1: PWM DC 16.4% (9.8 A)
2025-10-26T15:09:05.371Z:INFO:taskMain.c:6230:Socket #1: Active current 9.9->7.7 due to current limit: Active-LoadBalancing
2025-10-26T15:09:05.382Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (16.4->12.8)
2025-10-26T15:09:05.960Z:INFO:taskMain.c:6746:Socket #1: PWM DC 12.8% (7.7 A)
2025-10-26T15:09:06.371Z:INFO:taskMain.c:6798:Socket #1: reset HF switch count 1
2025-10-26T15:09:06.414Z:USER:taskMaster.c:6599:Socket #1: L1N=234.0V L2N=233.5V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:09:06.425Z:USER:taskMaster.c:6635:Socket #1: I1=9.4A I2=9.5A I3=9.5A P=6.6kW Idc=0.7mA
2025-10-26T15:09:17.371Z:INFO:taskMain.c:6230:Socket #1: Active current 7.7->11.1 due to current limit: Active-LoadBalancing
2025-10-26T15:09:18.082Z:INFO:taskMain.c:6746:Socket #1: PWM DC 18.5% (11.1 A)
2025-10-26T15:09:29.371Z:INFO:taskMain.c:6230:Socket #1: Active current 11.1->15.3 due to current limit: Active-LoadBalancing
2025-10-26T15:09:30.199Z:INFO:taskMain.c:6746:Socket #1: PWM DC 25.5% (15.3 A)
2025-10-26T15:09:36.410Z:USER:taskMaster.c:6599:Socket #1: L1N=233.4V L2N=232.8V L3N=231.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:09:36.421Z:USER:taskMaster.c:6635:Socket #1: I1=15.0A I2=15.0A I3=15.0A P=10.5kW Idc=0.7mA
2025-10-26T15:09:41.367Z:INFO:taskMain.c:6230:Socket #1: Active current 15.3->15.9 due to current limit: ChargingProfile
2025-10-26T15:09:41.410Z:INFO:taskMaster.c:4897:Socket #1: state led : CHARGING_POWER_ON
2025-10-26T15:09:42.316Z:INFO:taskMain.c:6746:Socket #1: PWM DC 26.5% (15.9 A)
2025-10-26T15:10:06.410Z:USER:taskMaster.c:6599:Socket #1: L1N=232.5V L2N=232.2V L3N=230.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:10:06.421Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.8kW Idc=0.7mA
2025-10-26T15:10:36.406Z:USER:taskMaster.c:6599:Socket #1: L1N=231.9V L2N=231.3V L3N=230.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:10:36.417Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.6A P=10.8kW Idc=0.7mA
2025-10-26T15:11:06.402Z:USER:taskMaster.c:6599:Socket #1: L1N=232.1V L2N=231.8V L3N=230.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:11:06.414Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.8kW Idc=0.7mA
2025-10-26T15:11:36.398Z:USER:taskMaster.c:6599:Socket #1: L1N=232.0V L2N=231.4V L3N=229.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:11:36.410Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-26T15:11:41.355Z:INFO:taskMain.c:6230:Socket #1: Active current 15.9->14.4 due to current limit: Active-LoadBalancing
2025-10-26T15:11:41.367Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->23.9)
2025-10-26T15:11:41.398Z:INFO:taskMaster.c:4897:Socket #1: state led : LOADBALANCING_LIMITED
2025-10-26T15:11:41.484Z:INFO:taskMain.c:6746:Socket #1: PWM DC 23.9% (14.3 A)
2025-10-26T15:11:53.355Z:INFO:taskMain.c:6230:Socket #1: Active current 14.4->10.6 due to current limit: Active-LoadBalancing
2025-10-26T15:11:53.367Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->17.6)
2025-10-26T15:11:53.605Z:INFO:taskMain.c:6746:Socket #1: PWM DC 17.6% (10.6 A)
2025-10-26T15:12:05.351Z:INFO:taskMain.c:6230:Socket #1: Active current 10.6->7.6 due to current limit: Active-LoadBalancing
2025-10-26T15:12:05.367Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (17.6->12.6)
2025-10-26T15:12:05.722Z:INFO:taskMain.c:6746:Socket #1: PWM DC 12.6% (7.6 A)
2025-10-26T15:12:06.394Z:USER:taskMaster.c:6599:Socket #1: L1N=235.7V L2N=235.1V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:12:06.406Z:USER:taskMaster.c:6635:Socket #1: I1=10.2A I2=10.2A I3=10.1A P=7.2kW Idc=0.7mA
2025-10-26T15:12:17.351Z:INFO:taskMain.c:6230:Socket #1: Active current 7.6->4.6 due to current limit: Active-LoadBalancing
2025-10-26T15:12:17.363Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (12.6->12.6)
2025-10-26T15:12:17.375Z:WARNING:taskMain.c:4848:Socket #1: maximum current(4.63) < minimum current(6.00)
2025-10-26T15:12:17.394Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-10-26T15:12:17.406Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_C1
2025-10-26T15:12:17.414Z:INFO:taskMaster.c:4897:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-10-26T15:12:17.425Z:COM:ocpp_rpc.c:715:-> [2,"42","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-26T15:12:17.425Z:COM:ocpp_rpc.c:715:"SuspendedEVSE"}]
2025-10-26T15:12:17.453Z:COM:ocpp_rpc.c:1292:<- [3,"42",{}]
2025-10-26T15:12:17.839Z:INFO:taskMain.c:6735:Socket #1: CPlow 6.3 V
2025-10-26T15:12:18.402Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 6.3/6.3, tag: 04BB
2025-10-26T15:12:18.402Z:INFO:taskMain.c:1424:29EAFD0F94
2025-10-26T15:12:19.410Z:INFO:taskMain.c:6730:Socket #1: CPhigh 9.2 V
2025-10-26T15:12:19.417Z:INFO:taskMain.c:6735:Socket #1: CPlow 9.3 V
2025-10-26T15:12:22.445Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_OFF_BYPASS_OFF
2025-10-26T15:12:22.453Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B1
2025-10-26T15:12:29.351Z:INFO:taskMain.c:6230:Socket #1: Active current 4.6->6.8 due to current limit: Active-LoadBalancing
2025-10-26T15:12:29.394Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_OFF
2025-10-26T15:12:29.402Z:INFO:taskMaster.c:4897:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-10-26T15:12:29.492Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B2
2025-10-26T15:12:29.511Z:INFO:taskMain.c:6735:Socket #1: CPlow -11.4 V
2025-10-26T15:12:29.519Z:INFO:taskMain.c:6746:Socket #1: PWM DC 11.2% (6.7 A)
2025-10-26T15:12:30.394Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_ON
2025-10-26T15:12:30.402Z:INFO:taskMaster.c:6553:Start logging meter values @30s.
2025-10-26T15:12:30.410Z:USER:taskMaster.c:6599:Socket #1: L1N=236.8V L2N=236.2V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:12:30.421Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-26T15:12:30.433Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_ON_BYPASS_ON
2025-10-26T15:12:30.445Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_C2
2025-10-26T15:12:30.457Z:INFO:taskMaster.c:4897:Socket #1: state led : LOADBALANCING_LIMITED
2025-10-26T15:12:30.468Z:COM:ocpp_rpc.c:715:-> [2,"43","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-26T15:12:30.468Z:COM:ocpp_rpc.c:715:"Charging"}]
2025-10-26T15:12:30.488Z:COM:ocpp_rpc.c:1292:<- [3,"43",{}]
2025-10-26T15:12:30.519Z:INFO:taskMain.c:6730:Socket #1: CPhigh 6.3 V
2025-10-26T15:12:31.378Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-10-26T15:12:41.347Z:INFO:taskMain.c:6230:Socket #1: Active current 6.8->11.8 due to current limit: Active-LoadBalancing
2025-10-26T15:12:41.480Z:INFO:taskMain.c:6746:Socket #1: PWM DC 19.6% (11.8 A)
2025-10-26T15:12:53.347Z:INFO:taskMain.c:6230:Socket #1: Active current 11.8->15.2 due to current limit: Active-LoadBalancing
2025-10-26T15:12:53.597Z:INFO:taskMain.c:6746:Socket #1: PWM DC 25.3% (15.2 A)
2025-10-26T15:13:00.441Z:USER:taskMaster.c:6599:Socket #1: L1N=234.8V L2N=234.8V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:13:00.453Z:USER:taskMaster.c:6635:Socket #1: I1=14.8A I2=14.8A I3=14.7A P=10.4kW Idc=0.7mA
2025-10-26T15:13:05.347Z:INFO:taskMain.c:6230:Socket #1: Active current 15.2->15.9 due to current limit: ChargingProfile
2025-10-26T15:13:05.390Z:INFO:taskMaster.c:4897:Socket #1: state led : CHARGING_POWER_ON
2025-10-26T15:13:05.714Z:INFO:taskMain.c:6746:Socket #1: PWM DC 26.5% (15.9 A)
2025-10-26T15:13:30.363Z:INFO:taskMain.c:6798:Socket #1: reset HF switch count 1
2025-10-26T15:13:30.437Z:USER:taskMaster.c:6599:Socket #1: L1N=235.0V L2N=235.0V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:13:30.449Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-10-26T15:13:46.734Z:INFO:active_lb.c:308:SMt:(16.0 16.0 21.0)A Free:(9.0 9.0 4.0)A ALB:(25.1 25.1 19.5)A
2025-10-26T15:14:00.433Z:USER:taskMaster.c:6599:Socket #1: L1N=234.8V L2N=234.1V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:14:00.445Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-10-26T15:14:30.429Z:USER:taskMaster.c:6599:Socket #1: L1N=234.9V L2N=234.5V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:14:30.441Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-10-26T15:14:53.335Z:INFO:taskMain.c:6230:Socket #1: Active current 15.9->14.4 due to current limit: Active-LoadBalancing
2025-10-26T15:14:53.347Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->24.0)
2025-10-26T15:14:53.378Z:INFO:taskMaster.c:4897:Socket #1: state led : LOADBALANCING_LIMITED
2025-10-26T15:14:53.773Z:INFO:taskMain.c:6746:Socket #1: PWM DC 24.0% (14.4 A)
2025-10-26T15:15:00.425Z:USER:taskMaster.c:6599:Socket #1: L1N=235.0V L2N=234.8V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:15:00.441Z:USER:taskMaster.c:6635:Socket #1: I1=14.1A I2=14.1A I3=14.1A P=9.9kW Idc=0.7mA
2025-10-26T15:15:05.332Z:INFO:taskMain.c:6230:Socket #1: Active current 14.4->12.3 due to current limit: Active-LoadBalancing
2025-10-26T15:15:05.347Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->20.4)
2025-10-26T15:15:05.894Z:INFO:taskMain.c:6746:Socket #1: PWM DC 20.4% (12.2 A)
2025-10-26T15:15:17.332Z:INFO:taskMain.c:6230:Socket #1: Active current 12.3->10.5 due to current limit: Active-LoadBalancing
2025-10-26T15:15:17.343Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (20.4->17.5)
2025-10-26T15:15:18.011Z:INFO:taskMain.c:6746:Socket #1: PWM DC 17.5% (10.5 A)
2025-10-26T15:15:29.332Z:INFO:taskMain.c:6230:Socket #1: Active current 10.5->10.0 due to current limit: Active-LoadBalancing
2025-10-26T15:15:29.343Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (17.5->16.6)
2025-10-26T15:15:30.132Z:INFO:taskMain.c:6746:Socket #1: PWM DC 16.6% (10.0 A)
2025-10-26T15:15:30.425Z:USER:taskMaster.c:6599:Socket #1: L1N=235.6V L2N=235.1V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:15:30.437Z:USER:taskMaster.c:6635:Socket #1: I1=10.2A I2=10.2A I3=10.2A P=7.2kW Idc=0.7mA
2025-10-26T15:15:41.328Z:INFO:taskMain.c:6230:Socket #1: Active current 10.0->9.8 due to current limit: Active-LoadBalancing
2025-10-26T15:15:41.343Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (16.6->16.3)
2025-10-26T15:15:53.328Z:INFO:taskMain.c:6230:Socket #1: Active current 9.8->10.0 due to current limit: Active-LoadBalancing
2025-10-26T15:16:00.421Z:USER:taskMaster.c:6599:Socket #1: L1N=235.3V L2N=235.1V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:16:00.433Z:USER:taskMaster.c:6635:Socket #1: I1=9.6A I2=9.6A I3=9.5A P=6.7kW Idc=0.7mA
2025-10-26T15:16:05.328Z:INFO:taskMain.c:6230:Socket #1: Active current 10.0->10.2 due to current limit: Active-LoadBalancing
2025-10-26T15:16:08.019Z:USER:taskMaster.c:6497:Temperature: 30.0 C
2025-10-26T15:16:17.324Z:INFO:taskMain.c:6230:Socket #1: Active current 10.2->10.4 due to current limit: Active-LoadBalancing
2025-10-26T15:16:29.324Z:INFO:taskMain.c:6230:Socket #1: Active current 10.4->10.7 due to current limit: Active-LoadBalancing
2025-10-26T15:16:30.417Z:USER:taskMaster.c:6599:Socket #1: L1N=235.2V L2N=235.3V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:16:30.429Z:USER:taskMaster.c:6635:Socket #1: I1=9.9A I2=10.0A I3=10.0A P=7.0kW Idc=0.7mA
2025-10-26T15:16:41.324Z:INFO:taskMain.c:6230:Socket #1: Active current 10.7->10.5 due to current limit: Active-LoadBalancing
2025-10-26T15:16:41.335Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (17.7->17.5)
2025-10-26T15:16:53.324Z:INFO:taskMain.c:6230:Socket #1: Active current 10.5->15.9 due to current limit: ChargingProfile
2025-10-26T15:16:53.363Z:INFO:taskMaster.c:4897:Socket #1: state led : CHARGING_POWER_ON
2025-10-26T15:16:53.953Z:INFO:taskMain.c:6746:Socket #1: PWM DC 26.5% (15.9 A)
2025-10-26T15:17:00.414Z:USER:taskMaster.c:6599:Socket #1: L1N=234.0V L2N=234.3V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:17:00.425Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-10-26T15:17:30.410Z:USER:taskMaster.c:6599:Socket #1: L1N=233.9V L2N=234.2V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:17:30.425Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-10-26T15:17:30.433Z:INFO:taskMaster.c:6541:Stop logging meter values @30s.
2025-10-26T15:22:31.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-26T15:22:48.980Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-26T15:22:48.988Z:INFO:db_chargingprofi:26: socket 0
2025-10-26T15:22:48.996Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-26T15:22:49.007Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-26T15:22:49.015Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-26T15:22:49.023Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-26T15:22:49.035Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-26T15:22:49.042Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-26T15:22:49.050Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-26T15:22:49.058Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-26T15:22:49.066Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-26T15:22:49.074Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-26T15:22:49.082Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-26T15:22:49.089Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-26T15:22:49.097Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-26T15:22:49.109Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-26T15:22:49.117Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-26T15:22:49.125Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-26T15:22:49.136Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-26T15:22:49.144Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-26T15:22:49.152Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-26T15:22:49.160Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-26T15:22:49.167Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-26T15:23:46.671Z:INFO:active_lb.c:308:SMt:(16.0 17.0 25.0)A Free:(9.0 8.0 0.0)A ALB:(24.6 23.6 16.0)A
2025-10-26T15:23:53.277Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->26.3)
2025-10-26T15:23:53.320Z:INFO:taskMaster.c:4897:Socket #1: state led : LOADBALANCING_LIMITED
2025-10-26T15:24:05.320Z:INFO:taskMaster.c:4897:Socket #1: state led : CHARGING_POWER_ON
2025-10-26T15:31:08.375Z:USER:taskMaster.c:6497:Temperature: 30.6 C
2025-10-26T15:32:30.316Z:USER:taskMaster.c:6599:Socket #1: L1N=233.7V L2N=234.2V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:32:30.328Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-10-26T15:33:46.609Z:INFO:active_lb.c:308:SMt:(16.0 17.0 16.0)A Free:(9.0 8.0 9.0)A ALB:(24.6 23.4 24.6)A
2025-10-26T15:37:31.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-26T15:43:46.542Z:INFO:active_lb.c:308:SMt:(17.0 18.0 16.0)A Free:(8.0 7.0 9.0)A ALB:(23.6 22.6 24.5)A
2025-10-26T15:46:08.781Z:USER:taskMaster.c:6497:Temperature: 31.4 C
2025-10-26T15:47:30.218Z:USER:taskMaster.c:6599:Socket #1: L1N=233.2V L2N=233.3V L3N=231.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T15:47:30.234Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.5A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-26T15:52:31.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-26T15:53:46.480Z:INFO:active_lb.c:308:SMt:(17.0 18.0 16.0)A Free:(8.0 7.0 9.0)A ALB:(23.8 22.6 24.6)A
2025-10-26T15:57:34.355Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_OFF
2025-10-26T15:57:34.367Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_OFF_BYPASS_OFF
2025-10-26T15:57:34.375Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B2
2025-10-26T15:57:34.386Z:INFO:taskMaster.c:4897:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-10-26T15:57:34.394Z:COM:ocpp_rpc.c:715:-> [2,"44","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-26T15:57:34.394Z:COM:ocpp_rpc.c:715:"SuspendedEV"}]
2025-10-26T15:57:34.417Z:COM:ocpp_rpc.c:1292:<- [3,"44",{}]
2025-10-26T15:57:34.914Z:INFO:taskMain.c:6730:Socket #1: CPhigh 9.2 V
2025-10-26T15:57:35.433Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.2/-11.4, tag: 04BB29EAFD0F94
2025-10-26T15:57:53.113Z:INFO:taskMain.c:6230:Socket #1: Active current 15.9->12.6 due to current limit: Active-LoadBalancing
2025-10-26T15:57:53.609Z:INFO:taskMain.c:6746:Socket #1: PWM DC 21.0% (12.6 A)
2025-10-26T15:58:04.402Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_WAKEUP
2025-10-26T15:58:04.414Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_E
2025-10-26T15:58:04.718Z:INFO:taskMain.c:6730:Socket #1: CPhigh 0.0 V
2025-10-26T15:58:04.726Z:INFO:taskMain.c:6735:Socket #1: CPlow 0.0 V
2025-10-26T15:58:05.109Z:INFO:taskMain.c:6230:Socket #1: Active current 12.6->15.9 due to current limit: ChargingProfile
2025-10-26T15:58:05.398Z:INFO:taskMain.c:6746:Socket #1: PWM DC 26.5% (15.9 A)
2025-10-26T15:58:05.410Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-10-26T15:58:08.402Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B1
2025-10-26T15:58:08.429Z:INFO:taskMain.c:6730:Socket #1: CPhigh 9.2 V
2025-10-26T15:58:08.437Z:INFO:taskMain.c:6735:Socket #1: CPlow 9.2 V
2025-10-26T15:58:08.902Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_OFF
2025-10-26T15:58:08.914Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B2
2025-10-26T15:58:09.460Z:INFO:taskMain.c:6735:Socket #1: CPlow -11.4 V
2025-10-26T15:58:09.968Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-10-26T15:58:34.367Z:INFO:taskMain.c:6798:Socket #1: reset HF switch count 1
2025-10-26T15:59:46.410Z:WARNING:taskMain.c:4908:Socket #1: EV disconnected while charging (11.3V)
2025-10-26T15:59:46.437Z:INFO:taskMain.c:6230:Socket #1: Active current 15.9->0.0 due to current limit: Cable
2025-10-26T15:59:46.449Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_WAIT_FOR_EV_RECONNECT
2025-10-26T15:59:46.460Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_A
2025-10-26T15:59:46.917Z:INFO:taskMain.c:6730:Socket #1: CPhigh 12.3 V
2025-10-26T15:59:46.925Z:INFO:taskMain.c:6735:Socket #1: CPlow 12.3 V
2025-10-26T15:59:46.933Z:INFO:taskMain.c:6740:Socket #1: PP 34464 Ohm (0 A)
2025-10-26T15:59:47.042Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_TERMINATING
2025-10-26T15:59:47.050Z:INFO:taskMaster.c:4897:Socket #1: state led : WAIT_FOR_VEHICLE
2025-10-26T15:59:47.062Z:COM:ocpp_rpc.c:715:-> [2,"45","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-26T15:59:47.062Z:COM:ocpp_rpc.c:715:"Finishing"}]
2025-10-26T15:59:47.093Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_E
2025-10-26T15:59:47.113Z:COM:ocpp_rpc.c:1292:<- [3,"45",{}]
2025-10-26T15:59:47.929Z:INFO:taskMain.c:6730:Socket #1: CPhigh 0.0 V
2025-10-26T15:59:47.937Z:INFO:taskMain.c:6735:Socket #1: CPlow 0.0 V
2025-10-26T15:59:48.160Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_TERMINATING, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-10-26T15:59:51.089Z:INFO:taskMaster.c:4875:Socket #1: state main : WAIT_FOR_STOP_METERVALUE
2025-10-26T15:59:51.707Z:INFO:taskMain.c:943:Socket #1: charging session status set inactive
2025-10-26T15:59:51.718Z:USER:board_ng9xx.c:5059:Socket #1: unlock socket motor
2025-10-26T15:59:51.742Z:INFO:taskMaster.c:4875:Socket #1: state main : WAIT_FOR_DISCONNECT
2025-10-26T15:59:52.839Z:INFO:board_ng9xx.c:5628:Socket 1: emergency relays check OK
2025-10-26T15:59:54.082Z:INFO:db_transaction.c:16:Added TransactionStop for socket 1 at 0x000b7ba4 (ts: 2025-10-26 15:59:51)
2025-10-26T15:59:54.097Z:INFO:db_transaction.c:16:Updated TransactionStart for socket 1 at 0x000b7aa8 (ts: 2025-10-26 14:22:30)
2025-10-26T15:59:54.160Z:INFO:taskMaster.c:4897:Socket #1: state led : AVAILABLE
2025-10-26T15:59:54.167Z:COM:ocpp_rpc.c:715:-> [2,"46","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-26T15:59:54.167Z:COM:ocpp_rpc.c:715:"Available"}]
2025-10-26T15:59:54.187Z:INFO:taskMaster.c:4875:Socket #1: state main : AVAILABLE
2025-10-26T15:59:54.199Z:INFO:taskMain.c:6676:Socket #1: active tag cleared
2025-10-26T15:59:54.210Z:COM:ocpp_rpc.c:1292:<- [3,"46",{}]
2025-10-26T15:59:55.148Z:INFO:taskMain.c:1426:Socket #1: main state: AVAILABLE, CP: 0.0/0.0, no tag
2025-10-26T16:01:09.183Z:USER:taskMaster.c:6497:Temperature: 31.4 C
2025-10-26T16:02:30.125Z:USER:taskMaster.c:6599:Socket #1: L1N=235.9V L2N=235.3V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T16:03:46.417Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(23.0 22.0 24.0)A ALB:(23.6 22.0 24.0)A
2025-10-26T16:13:46.351Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-26T16:16:09.539Z:USER:taskMaster.c:6497:Temperature: 28.4 C
2025-10-26T16:17:30.031Z:USER:taskMaster.c:6599:Socket #1: L1N=232.9V L2N=232.0V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T16:23:46.289Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-26T16:31:09.945Z:USER:taskMaster.c:6497:Temperature: 26.8 C
2025-10-26T16:32:10.796Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-10-26T16:32:29.933Z:USER:taskMaster.c:6599:Socket #1: L1N=231.5V L2N=230.5V L3N=231.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T16:33:46.226Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.6 24.0)A
2025-10-26T16:42:10.734Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-10-26T16:43:29.070Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-26T16:43:29.339Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-26T16:43:37.746Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-26T16:43:37.757Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-26T16:43:46.164Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(23.8 23.0 24.0)A
2025-10-26T16:46:10.300Z:USER:taskMaster.c:6497:Temperature: 25.2 C
2025-10-26T16:47:29.839Z:USER:taskMaster.c:6599:Socket #1: L1N=232.8V L2N=233.7V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T16:52:10.769Z:INFO:taskLeds.c:338:Brightness set to 8%
2025-10-26T16:53:46.101Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(23.1 23.0 24.0)A
2025-10-26T17:01:10.703Z:USER:taskMaster.c:6497:Temperature: 24.2 C
2025-10-26T17:02:29.746Z:USER:taskMaster.c:6599:Socket #1: L1N=234.3V L2N=234.0V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T17:03:46.035Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.0 24.0 24.0)A
2025-10-26T17:13:45.972Z:INFO:active_lb.c:308:SMt:(2.0 2.0 2.0)A Free:(23.0 23.0 23.0)A ALB:(23.0 23.0 20.6)A
2025-10-26T17:16:11.058Z:USER:taskMaster.c:6497:Temperature: 23.6 C
2025-10-26T17:17:29.648Z:USER:taskMaster.c:6599:Socket #1: L1N=233.8V L2N=233.9V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T17:23:45.910Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(23.2 23.0 21.2)A
2025-10-26T17:31:11.464Z:USER:taskMaster.c:6497:Temperature: 23.2 C
2025-10-26T17:32:29.554Z:USER:taskMaster.c:6599:Socket #1: L1N=234.4V L2N=235.5V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T17:33:45.847Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(22.4 24.0 24.0)A
2025-10-26T17:43:45.781Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(23.1 23.0 24.0)A
2025-10-26T17:46:11.816Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-26T17:47:29.460Z:USER:taskMaster.c:6599:Socket #1: L1N=232.1V L2N=232.5V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T17:53:45.718Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.3 24.0)A
2025-10-26T18:01:12.171Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-26T18:02:29.363Z:USER:taskMaster.c:6599:Socket #1: L1N=232.8V L2N=232.7V L3N=232.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T18:03:45.656Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 23.9)A
2025-10-26T18:13:45.593Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(23.2 23.0 24.0)A
2025-10-26T18:16:12.578Z:USER:taskMaster.c:6497:Temperature: 22.8 C
2025-10-26T18:17:29.269Z:USER:taskMaster.c:6599:Socket #1: L1N=232.8V L2N=233.4V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T18:23:45.527Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 22.9 24.0)A
2025-10-26T18:31:12.929Z:USER:taskMaster.c:6497:Temperature: 22.6 C
2025-10-26T18:32:29.171Z:USER:taskMaster.c:6599:Socket #1: L1N=232.6V L2N=234.3V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T18:33:45.464Z:INFO:active_lb.c:308:SMt:(7.0 2.0 1.0)A Free:(18.0 23.0 24.0)A ALB:(20.9 23.0 24.0)A
2025-10-26T18:43:36.984Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-26T18:43:36.992Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-26T18:43:45.402Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-26T18:46:13.335Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-26T18:47:29.078Z:USER:taskMaster.c:6599:Socket #1: L1N=235.4V L2N=235.8V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T18:53:45.335Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(24.0 23.0 23.0)A ALB:(24.0 23.0 23.4)A
2025-10-26T19:01:13.738Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-26T19:02:28.980Z:USER:taskMaster.c:6599:Socket #1: L1N=229.7V L2N=230.5V L3N=230.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T19:03:45.273Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-26T19:13:45.210Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-26T19:16:14.093Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-26T19:17:28.886Z:USER:taskMaster.c:6599:Socket #1: L1N=234.9V L2N=235.3V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T19:23:45.144Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-26T19:31:14.500Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-26T19:32:28.789Z:USER:taskMaster.c:6599:Socket #1: L1N=232.7V L2N=233.3V L3N=231.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T19:33:45.082Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-26T19:43:45.019Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-26T19:46:14.851Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-26T19:47:28.695Z:USER:taskMaster.c:6599:Socket #1: L1N=233.9V L2N=233.6V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T19:53:44.953Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-26T20:01:15.257Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-26T20:02:28.597Z:USER:taskMaster.c:6599:Socket #1: L1N=233.6V L2N=233.8V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T20:03:44.890Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-26T20:13:44.828Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(23.9 24.0 23.0)A
2025-10-26T20:16:15.660Z:USER:taskMaster.c:6497:Temperature: 22.0 C
2025-10-26T20:17:28.503Z:USER:taskMaster.c:6599:Socket #1: L1N=235.1V L2N=234.7V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T20:23:44.761Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T20:31:16.066Z:USER:taskMaster.c:6497:Temperature: 21.9 C
2025-10-26T20:32:28.406Z:USER:taskMaster.c:6599:Socket #1: L1N=236.4V L2N=236.1V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T20:33:44.699Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T20:43:27.250Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-26T20:43:27.519Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-26T20:43:36.218Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-26T20:43:36.226Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-26T20:43:44.636Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T20:43:44.683Z:INFO:comFaults.c:482:Reset fault status
2025-10-26T20:46:16.417Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-26T20:47:28.312Z:USER:taskMaster.c:6599:Socket #1: L1N=232.9V L2N=232.5V L3N=231.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T20:53:44.570Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T21:01:16.773Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-26T21:02:28.214Z:USER:taskMaster.c:6599:Socket #1: L1N=234.0V L2N=234.2V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T21:03:44.507Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.9 24.0 24.0)A
2025-10-26T21:13:44.445Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.4 24.0 24.0)A
2025-10-26T21:16:17.175Z:USER:taskMaster.c:6497:Temperature: 21.4 C
2025-10-26T21:17:28.121Z:USER:taskMaster.c:6599:Socket #1: L1N=234.0V L2N=233.5V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T21:23:44.378Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.4 24.0 24.0)A
2025-10-26T21:31:17.582Z:USER:taskMaster.c:6497:Temperature: 21.6 C
2025-10-26T21:32:28.023Z:USER:taskMaster.c:6599:Socket #1: L1N=234.9V L2N=234.4V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T21:33:44.316Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(22.9 24.0 24.0)A
2025-10-26T21:43:44.250Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T21:46:17.937Z:USER:taskMaster.c:6497:Temperature: 21.6 C
2025-10-26T21:47:27.929Z:USER:taskMaster.c:6599:Socket #1: L1N=233.6V L2N=233.2V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T21:53:44.187Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T22:01:18.339Z:USER:taskMaster.c:6497:Temperature: 21.4 C
2025-10-26T22:02:27.832Z:USER:taskMaster.c:6599:Socket #1: L1N=235.0V L2N=234.6V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T22:03:44.125Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T22:13:44.058Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T22:16:18.695Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-26T22:17:27.734Z:USER:taskMaster.c:6599:Socket #1: L1N=237.3V L2N=236.5V L3N=236.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T22:23:43.996Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T22:31:19.097Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-26T22:32:27.640Z:USER:taskMaster.c:6599:Socket #1: L1N=234.3V L2N=234.1V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T22:33:43.933Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T22:43:35.449Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-26T22:43:35.460Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-26T22:43:43.867Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T22:46:19.500Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-26T22:47:27.542Z:USER:taskMaster.c:6599:Socket #1: L1N=235.2V L2N=234.9V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T22:53:43.804Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T23:00:00.062Z:INFO:taskMaster.c:6271:Socket #1: external current limit 15.9 A until 2025-10-27T23:00:00Z
2025-10-26T23:01:19.605Z:USER:taskMaster.c:6497:Temperature: 20.9 C
2025-10-26T23:02:27.449Z:USER:taskMaster.c:6599:Socket #1: L1N=235.0V L2N=234.4V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T23:03:43.738Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T23:13:43.675Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T23:16:19.808Z:USER:taskMaster.c:6497:Temperature: 20.9 C
2025-10-26T23:17:27.351Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=233.6V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T23:23:43.613Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.2 24.0 24.0)A
2025-10-26T23:31:20.214Z:USER:taskMaster.c:6497:Temperature: 20.9 C
2025-10-26T23:32:27.257Z:USER:taskMaster.c:6599:Socket #1: L1N=236.6V L2N=236.4V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T23:33:43.546Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T23:43:43.484Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-26T23:46:20.617Z:USER:taskMaster.c:6497:Temperature: 20.9 C
2025-10-26T23:47:27.160Z:USER:taskMaster.c:6599:Socket #1: L1N=237.3V L2N=237.4V L3N=236.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-26T23:53:43.417Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.2 24.0 24.0)A
2025-10-27T00:01:20.972Z:USER:taskMaster.c:6497:Temperature: 21.0 C
2025-10-27T00:02:27.062Z:USER:taskMaster.c:6599:Socket #1: L1N=236.6V L2N=237.2V L3N=236.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T00:03:43.355Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T00:13:43.292Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T00:16:21.324Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-27T00:17:26.968Z:USER:taskMaster.c:6599:Socket #1: L1N=237.2V L2N=237.5V L3N=237.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T00:23:43.226Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T00:31:21.777Z:USER:taskMaster.c:6497:Temperature: 21.2 C
2025-10-27T00:32:26.871Z:USER:taskMaster.c:6599:Socket #1: L1N=237.7V L2N=237.6V L3N=237.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T00:33:43.164Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T00:43:25.414Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-27T00:43:25.683Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-27T00:43:34.679Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-27T00:43:34.691Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-27T00:43:43.097Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T00:46:22.183Z:USER:taskMaster.c:6497:Temperature: 21.2 C
2025-10-27T00:47:26.777Z:USER:taskMaster.c:6599:Socket #1: L1N=233.9V L2N=234.4V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T00:53:43.035Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T01:01:22.488Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-27T01:02:26.679Z:USER:taskMaster.c:6599:Socket #1: L1N=233.5V L2N=234.6V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T01:03:42.972Z:INFO:active_lb.c:308:SMt:(7.0 1.0 1.0)A Free:(18.0 24.0 24.0)A ALB:(18.0 24.0 24.0)A
2025-10-27T01:13:42.906Z:INFO:active_lb.c:308:SMt:(7.0 1.0 1.0)A Free:(18.0 24.0 24.0)A ALB:(18.0 24.0 24.0)A
2025-10-27T01:16:22.941Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-27T01:17:26.582Z:USER:taskMaster.c:6599:Socket #1: L1N=234.8V L2N=235.1V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T01:23:42.843Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T01:31:23.246Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-27T01:32:26.488Z:USER:taskMaster.c:6599:Socket #1: L1N=233.5V L2N=234.8V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T01:33:42.781Z:INFO:active_lb.c:308:SMt:(10.0 1.0 1.0)A Free:(15.0 24.0 24.0)A ALB:(15.0 24.0 24.0)A
2025-10-27T01:43:42.714Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 24.0 24.0)A
2025-10-27T01:46:23.648Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-27T01:47:26.390Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=235.4V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T01:53:42.652Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 24.0 24.0)A
2025-10-27T02:01:24.054Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-27T02:02:26.296Z:USER:taskMaster.c:6599:Socket #1: L1N=233.5V L2N=235.0V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T02:03:42.585Z:INFO:active_lb.c:308:SMt:(11.0 1.0 5.0)A Free:(14.0 24.0 20.0)A ALB:(14.2 24.0 20.0)A
2025-10-27T02:13:42.523Z:INFO:active_lb.c:308:SMt:(2.0 1.0 5.0)A Free:(23.0 24.0 20.0)A ALB:(23.1 24.0 20.0)A
2025-10-27T02:16:24.406Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-27T02:17:26.199Z:USER:taskMaster.c:6599:Socket #1: L1N=233.7V L2N=233.9V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T02:23:42.460Z:INFO:active_lb.c:308:SMt:(2.0 1.0 5.0)A Free:(23.0 24.0 20.0)A ALB:(23.0 24.0 20.0)A
2025-10-27T02:31:24.761Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-27T02:32:26.105Z:USER:taskMaster.c:6599:Socket #1: L1N=233.9V L2N=234.6V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T02:33:42.394Z:INFO:active_lb.c:308:SMt:(2.0 1.0 5.0)A Free:(23.0 24.0 20.0)A ALB:(23.2 24.0 20.0)A
2025-10-27T02:43:33.914Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-27T02:43:33.925Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-27T02:43:42.332Z:INFO:active_lb.c:308:SMt:(2.0 1.0 5.0)A Free:(23.0 24.0 20.0)A ALB:(22.5 24.0 20.0)A
2025-10-27T02:46:25.117Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-27T02:47:26.007Z:USER:taskMaster.c:6599:Socket #1: L1N=233.9V L2N=234.5V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T02:53:42.269Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(23.8 24.0 20.0)A
2025-10-27T03:01:25.519Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-27T03:02:25.914Z:USER:taskMaster.c:6599:Socket #1: L1N=233.4V L2N=233.6V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T03:03:42.203Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-27T03:13:42.140Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-27T03:16:25.921Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-27T03:17:25.816Z:USER:taskMaster.c:6599:Socket #1: L1N=237.2V L2N=237.8V L3N=236.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T03:23:42.078Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-27T03:31:26.277Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-27T03:32:25.722Z:USER:taskMaster.c:6599:Socket #1: L1N=237.7V L2N=238.0V L3N=237.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T03:33:42.011Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-27T03:43:41.949Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-27T03:46:26.683Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-27T03:47:25.625Z:USER:taskMaster.c:6599:Socket #1: L1N=236.8V L2N=237.0V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T03:53:41.886Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-27T04:01:27.035Z:USER:taskMaster.c:6497:Temperature: 21.6 C
2025-10-27T04:02:25.527Z:USER:taskMaster.c:6599:Socket #1: L1N=236.1V L2N=236.1V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T04:03:41.820Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-27T04:13:41.757Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-27T04:16:27.441Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-27T04:17:25.433Z:USER:taskMaster.c:6599:Socket #1: L1N=235.1V L2N=235.3V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T04:23:41.691Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 23.7 20.0)A
2025-10-27T04:31:27.894Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-27T04:32:25.335Z:USER:taskMaster.c:6599:Socket #1: L1N=235.7V L2N=236.0V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T04:33:41.628Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-27T04:43:24.578Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-27T04:43:24.847Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-27T04:43:33.148Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-27T04:43:33.156Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-27T04:43:41.566Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-27T04:46:28.199Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-27T04:47:25.242Z:USER:taskMaster.c:6599:Socket #1: L1N=234.3V L2N=235.2V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T04:53:41.500Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-27T05:01:28.601Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-27T05:02:25.144Z:USER:taskMaster.c:6599:Socket #1: L1N=235.9V L2N=236.3V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T05:03:41.437Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T05:13:41.375Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T05:16:28.957Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-27T05:17:25.050Z:USER:taskMaster.c:6599:Socket #1: L1N=236.0V L2N=236.7V L3N=236.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T05:23:41.308Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T05:31:29.359Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-27T05:32:24.953Z:USER:taskMaster.c:6599:Socket #1: L1N=234.2V L2N=234.9V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T05:33:41.246Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T05:43:41.183Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-27T05:46:29.765Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-27T05:47:24.859Z:USER:taskMaster.c:6599:Socket #1: L1N=233.8V L2N=234.3V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T05:53:41.117Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-27T05:55:38.867Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-10-27T06:01:30.117Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-27T06:02:24.761Z:USER:taskMaster.c:6599:Socket #1: L1N=234.9V L2N=235.8V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T06:03:41.054Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.0 24.0 23.4)A
2025-10-27T06:05:38.902Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-10-27T06:13:40.992Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T06:15:38.839Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-10-27T06:16:30.523Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-27T06:17:24.667Z:USER:taskMaster.c:6599:Socket #1: L1N=234.4V L2N=235.4V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T06:23:40.925Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 24.0 24.0)A
2025-10-27T06:31:30.878Z:USER:taskMaster.c:6497:Temperature: 22.5 C
2025-10-27T06:32:24.570Z:USER:taskMaster.c:6599:Socket #1: L1N=234.0V L2N=234.6V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T06:33:40.863Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T06:43:32.382Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-27T06:43:32.390Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-27T06:43:40.800Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(23.8 24.0 23.0)A
2025-10-27T06:46:31.281Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-27T06:47:24.476Z:USER:taskMaster.c:6599:Socket #1: L1N=232.1V L2N=233.1V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T06:53:40.734Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(22.9 24.0 23.0)A
2025-10-27T07:01:31.687Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-27T07:02:24.378Z:USER:taskMaster.c:6599:Socket #1: L1N=234.9V L2N=235.4V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T07:03:40.671Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(24.0 23.0 23.0)A ALB:(24.0 23.0 23.0)A
2025-10-27T07:13:40.609Z:INFO:active_lb.c:308:SMt:(2.0 2.0 2.0)A Free:(23.0 23.0 23.0)A ALB:(23.6 23.0 23.0)A
2025-10-27T07:16:32.039Z:USER:taskMaster.c:6497:Temperature: 22.6 C
2025-10-27T07:17:24.285Z:USER:taskMaster.c:6599:Socket #1: L1N=236.5V L2N=236.3V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T07:23:40.542Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.0 24.0 23.0)A
2025-10-27T07:31:32.445Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-27T07:32:24.187Z:USER:taskMaster.c:6599:Socket #1: L1N=234.5V L2N=234.6V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T07:33:40.480Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.0 24.0 23.0)A
2025-10-27T07:43:40.417Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(26.0 24.0 23.0)A
2025-10-27T07:46:32.800Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-27T07:47:24.093Z:USER:taskMaster.c:6599:Socket #1: L1N=233.2V L2N=233.2V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T07:53:40.351Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(24.0 23.0 23.0)A ALB:(24.0 24.0 23.0)A
2025-10-27T08:01:33.203Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-27T08:02:23.996Z:USER:taskMaster.c:6599:Socket #1: L1N=233.9V L2N=234.6V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T08:03:40.289Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(24.0 23.0 23.0)A ALB:(24.0 23.0 23.0)A
2025-10-27T08:13:40.226Z:INFO:active_lb.c:308:SMt:(2.0 2.0 2.0)A Free:(23.0 23.0 23.0)A ALB:(23.0 23.0 21.7)A
2025-10-27T08:16:33.609Z:USER:taskMaster.c:6497:Temperature: 22.5 C
2025-10-27T08:17:23.902Z:USER:taskMaster.c:6599:Socket #1: L1N=233.5V L2N=234.6V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T08:23:40.164Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.0 24.0 22.9)A
2025-10-27T08:31:33.960Z:USER:taskMaster.c:6497:Temperature: 22.6 C
2025-10-27T08:32:23.804Z:USER:taskMaster.c:6599:Socket #1: L1N=233.1V L2N=234.4V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T08:33:40.097Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(25.3 24.0 23.0)A
2025-10-27T08:43:22.750Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-27T08:43:23.019Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-27T08:43:31.617Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-27T08:43:31.628Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-27T08:43:40.035Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.6 24.0 23.0)A
2025-10-27T08:43:40.085Z:INFO:comFaults.c:482:Reset fault status
2025-10-27T08:43:41.824Z:COM:ocpp_rpc.c:715:-> [2,"47","Heartbeat",{}]
2025-10-27T08:43:41.859Z:COM:ocpp_rpc.c:1292:<- [3,"47",{"currentTime":"2025-10-27T08:43:47.284Z"}]
2025-10-27T08:43:47.000Z:SECURITY:taskTime.c:603:Time changed
2025-10-27T08:46:39.496Z:USER:taskMaster.c:6497:Temperature: 22.6 C
2025-10-27T08:47:28.839Z:USER:taskMaster.c:6599:Socket #1: L1N=234.2V L2N=235.0V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T08:53:45.097Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 2.0)A Free:(26.0 23.0 23.0)A ALB:(26.0 23.0 23.0)A
2025-10-27T09:01:39.847Z:USER:taskMaster.c:6497:Temperature: 22.8 C
2025-10-27T09:02:28.742Z:USER:taskMaster.c:6599:Socket #1: L1N=234.9V L2N=235.0V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T09:03:45.035Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(25.2 24.0 23.0)A
2025-10-27T09:13:44.972Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.0 24.0 23.0)A
2025-10-27T09:16:40.203Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-27T09:17:28.648Z:USER:taskMaster.c:6599:Socket #1: L1N=235.4V L2N=236.4V L3N=235.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T09:23:44.906Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(26.0 24.0 23.0)A
2025-10-27T09:31:40.609Z:USER:taskMaster.c:6497:Temperature: 23.0 C
2025-10-27T09:32:28.550Z:USER:taskMaster.c:6599:Socket #1: L1N=233.6V L2N=234.0V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T09:33:44.843Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.0 24.0 23.0)A
2025-10-27T09:43:44.781Z:INFO:active_lb.c:308:SMt:(2.0 2.0 2.0)A Free:(23.0 23.0 23.0)A ALB:(23.2 23.0 23.0)A
2025-10-27T09:46:40.960Z:USER:taskMaster.c:6497:Temperature: 23.0 C
2025-10-27T09:47:28.457Z:USER:taskMaster.c:6599:Socket #1: L1N=232.2V L2N=233.0V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T09:53:44.718Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(24.8 24.0 23.0)A
2025-10-27T10:01:41.367Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-27T10:02:28.363Z:USER:taskMaster.c:6599:Socket #1: L1N=233.6V L2N=233.4V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T10:03:44.652Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 5.0)A Free:(26.0 24.0 20.0)A ALB:(26.0 24.0 20.0)A
2025-10-27T10:13:44.589Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 5.0)A Free:(26.0 24.0 20.0)A ALB:(26.0 24.0 20.5)A
2025-10-27T10:16:41.722Z:USER:taskMaster.c:6497:Temperature: 23.2 C
2025-10-27T10:17:28.265Z:USER:taskMaster.c:6599:Socket #1: L1N=231.3V L2N=232.4V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T10:23:44.527Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(24.0 23.0 23.0)A ALB:(24.0 23.0 20.6)A
2025-10-27T10:31:42.125Z:USER:taskMaster.c:6497:Temperature: 23.5 C
2025-10-27T10:32:28.171Z:USER:taskMaster.c:6599:Socket #1: L1N=231.1V L2N=232.8V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T10:33:44.460Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(24.0 23.0 23.0)A ALB:(24.5 23.0 20.1)A
2025-10-27T10:43:35.980Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-27T10:43:35.992Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-27T10:43:44.398Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.2 24.0 21.3)A
2025-10-27T10:46:42.531Z:USER:taskMaster.c:6497:Temperature: 23.2 C
2025-10-27T10:47:28.074Z:USER:taskMaster.c:6599:Socket #1: L1N=235.8V L2N=236.4V L3N=235.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T10:53:44.335Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(26.0 24.0 22.6)A
2025-10-27T11:01:42.933Z:USER:taskMaster.c:6497:Temperature: 23.4 C
2025-10-27T11:02:27.980Z:USER:taskMaster.c:6599:Socket #1: L1N=236.1V L2N=235.4V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T11:03:44.273Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(26.0 24.0 23.0)A
2025-10-27T11:13:44.207Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(24.0 23.0 23.0)A ALB:(24.0 23.0 23.0)A
2025-10-27T11:16:43.289Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-27T11:17:27.882Z:USER:taskMaster.c:6599:Socket #1: L1N=233.8V L2N=234.4V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T11:23:44.144Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(24.0 23.0 23.0)A ALB:(24.0 23.0 23.0)A
2025-10-27T11:31:43.644Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-27T11:32:27.789Z:USER:taskMaster.c:6599:Socket #1: L1N=236.9V L2N=237.5V L3N=238.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T11:33:44.082Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 9.0)A Free:(26.0 27.0 16.0)A ALB:(26.6 27.4 16.7)A
2025-10-27T11:43:44.015Z:INFO:active_lb.c:308:SMt:(-2.0 -3.0 2.0)A Free:(27.0 28.0 23.0)A ALB:(26.0 27.9 23.0)A
2025-10-27T11:46:44.050Z:USER:taskMaster.c:6497:Temperature: 23.0 C
2025-10-27T11:47:27.695Z:USER:taskMaster.c:6599:Socket #1: L1N=236.5V L2N=234.9V L3N=237.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T11:53:43.953Z:INFO:active_lb.c:308:SMt:(-2.0 -3.0 2.0)A Free:(27.0 28.0 23.0)A ALB:(27.0 26.2 23.0)A
2025-10-27T12:01:44.453Z:USER:taskMaster.c:6497:Temperature: 23.2 C
2025-10-27T12:02:27.597Z:USER:taskMaster.c:6599:Socket #1: L1N=235.6V L2N=235.9V L3N=237.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T12:03:43.890Z:INFO:active_lb.c:308:SMt:(-2.0 -3.0 2.0)A Free:(27.0 28.0 23.0)A ALB:(26.9 27.4 23.0)A
2025-10-27T12:13:43.828Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(24.0 23.0 23.0)A ALB:(24.0 23.2 22.6)A
2025-10-27T12:16:44.808Z:USER:taskMaster.c:6497:Temperature: 23.5 C
2025-10-27T12:17:27.503Z:USER:taskMaster.c:6599:Socket #1: L1N=236.2V L2N=236.8V L3N=236.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T12:23:43.761Z:INFO:active_lb.c:308:SMt:(-3.0 2.0 5.0)A Free:(28.0 23.0 20.0)A ALB:(27.0 23.0 21.7)A
2025-10-27T12:31:45.210Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-27T12:32:27.410Z:USER:taskMaster.c:6599:Socket #1: L1N=239.2V L2N=239.7V L3N=239.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T12:33:43.699Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 2.0)A Free:(26.0 23.0 23.0)A ALB:(26.2 24.3 21.8)A
2025-10-27T12:43:26.046Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-27T12:43:26.316Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-27T12:43:35.218Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-27T12:43:35.230Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-27T12:43:43.636Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 2.0)A Free:(26.0 27.0 23.0)A ALB:(24.9 25.5 22.7)A
2025-10-27T12:46:45.566Z:USER:taskMaster.c:6497:Temperature: 23.4 C
2025-10-27T12:47:27.312Z:USER:taskMaster.c:6599:Socket #1: L1N=237.7V L2N=238.8V L3N=237.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T12:53:43.574Z:INFO:active_lb.c:308:SMt:(-2.0 9.0 2.0)A Free:(27.0 16.0 23.0)A ALB:(25.1 16.0 22.9)A
2025-10-27T13:01:45.972Z:USER:taskMaster.c:6497:Temperature: 23.4 C
2025-10-27T13:02:27.218Z:USER:taskMaster.c:6599:Socket #1: L1N=231.8V L2N=232.6V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T13:03:43.507Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 2.0)A Free:(26.0 26.0 23.0)A ALB:(26.0 25.1 22.9)A
2025-10-27T13:13:43.445Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 2.0)A Free:(27.0 27.0 23.0)A ALB:(27.0 26.7 22.2)A
2025-10-27T13:16:46.375Z:USER:taskMaster.c:6497:Temperature: 23.6 C
2025-10-27T13:17:27.121Z:USER:taskMaster.c:6599:Socket #1: L1N=238.0V L2N=239.5V L3N=240.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T13:23:43.382Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(26.0 24.0 22.7)A
2025-10-27T13:31:46.730Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-27T13:32:27.027Z:USER:taskMaster.c:6599:Socket #1: L1N=232.9V L2N=234.2V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T13:33:43.316Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 5.0)A Free:(26.0 24.0 20.0)A ALB:(24.8 24.0 21.1)A
2025-10-27T13:43:43.253Z:INFO:active_lb.c:308:SMt:(1.0 -2.0 2.0)A Free:(24.0 27.0 23.0)A ALB:(24.7 27.0 23.0)A
2025-10-27T13:46:47.136Z:USER:taskMaster.c:6497:Temperature: 22.8 C
2025-10-27T13:47:26.929Z:USER:taskMaster.c:6599:Socket #1: L1N=235.0V L2N=235.8V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T13:53:43.191Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 2.0)A Free:(26.0 27.0 23.0)A ALB:(26.0 26.2 22.8)A
2025-10-27T14:01:47.488Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-27T14:02:26.835Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=236.3V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T14:03:43.128Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 2.0)A Free:(26.0 26.0 23.0)A ALB:(26.0 26.0 22.2)A
2025-10-27T14:13:43.062Z:INFO:active_lb.c:308:SMt:(8.0 -1.0 5.0)A Free:(17.0 26.0 20.0)A ALB:(17.0 26.0 21.8)A
2025-10-27T14:16:47.894Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-27T14:17:26.738Z:USER:taskMaster.c:6599:Socket #1: L1N=236.2V L2N=237.4V L3N=236.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T14:22:34.609Z:INFO:taskMaster.c:6294:Socket #1: no schedule
2025-10-27T14:22:34.617Z:USER:taskMaster.c:6318:Socket #1: external current limit 16.0 A
2025-10-27T14:23:43.000Z:INFO:active_lb.c:308:SMt:(3.0 1.0 2.0)A Free:(22.0 24.0 23.0)A ALB:(22.0 24.1 23.0)A
2025-10-27T14:31:48.500Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-27T14:32:26.644Z:USER:taskMaster.c:6599:Socket #1: L1N=232.2V L2N=233.4V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T14:33:42.937Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.3 24.0 21.5)A
2025-10-27T14:43:34.453Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-27T14:43:34.464Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-27T14:43:42.871Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(25.4 24.0 23.0)A
2025-10-27T14:46:49.152Z:USER:taskMaster.c:6497:Temperature: 23.4 C
2025-10-27T14:47:26.550Z:USER:taskMaster.c:6599:Socket #1: L1N=233.2V L2N=234.8V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T14:53:42.808Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(23.8 24.1 23.0)A
2025-10-27T15:01:49.558Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-27T15:02:26.453Z:USER:taskMaster.c:6599:Socket #1: L1N=235.5V L2N=236.2V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T15:03:42.746Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.2 24.0 22.8)A
2025-10-27T15:13:42.683Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(24.9 24.0 22.3)A
2025-10-27T15:16:49.863Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-27T15:17:26.359Z:USER:taskMaster.c:6599:Socket #1: L1N=231.8V L2N=232.2V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T15:23:42.617Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.1 24.0 23.0)A
2025-10-27T15:31:50.265Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-27T15:32:26.261Z:USER:taskMaster.c:6599:Socket #1: L1N=233.5V L2N=235.0V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T15:33:42.554Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.0 24.0 22.1)A
2025-10-27T15:43:42.492Z:INFO:active_lb.c:308:SMt:(2.0 3.0 2.0)A Free:(23.0 22.0 23.0)A ALB:(23.1 22.0 23.0)A
2025-10-27T15:46:50.722Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-27T15:47:26.167Z:USER:taskMaster.c:6599:Socket #1: L1N=231.1V L2N=231.0V L3N=230.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T15:53:42.429Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(24.0 22.0 23.0)A ALB:(24.0 22.0 23.0)A
2025-10-27T16:01:51.128Z:USER:taskMaster.c:6497:Temperature: 23.0 C
2025-10-27T16:02:26.074Z:USER:taskMaster.c:6599:Socket #1: L1N=233.4V L2N=234.4V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T16:03:42.363Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(23.4 22.9 23.5)A
2025-10-27T16:13:42.300Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(23.0 22.0 24.0)A ALB:(23.0 22.0 23.4)A
2025-10-27T16:16:51.582Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-27T16:17:25.976Z:USER:taskMaster.c:6599:Socket #1: L1N=235.2V L2N=236.9V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T16:23:42.238Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-27T16:30:09.855Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-10-27T16:31:51.984Z:USER:taskMaster.c:6497:Temperature: 22.8 C
2025-10-27T16:32:25.882Z:USER:taskMaster.c:6599:Socket #1: L1N=233.5V L2N=234.1V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T16:33:42.171Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-27T16:40:09.894Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-10-27T16:43:25.296Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-27T16:43:25.566Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-27T16:43:33.691Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-27T16:43:33.703Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-27T16:43:42.109Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 23.9)A
2025-10-27T16:46:52.390Z:USER:taskMaster.c:6497:Temperature: 22.8 C
2025-10-27T16:47:25.785Z:USER:taskMaster.c:6599:Socket #1: L1N=232.0V L2N=231.7V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T16:50:09.828Z:INFO:taskLeds.c:338:Brightness set to 8%
2025-10-27T16:53:42.046Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(23.2 22.0 23.9)A
2025-10-27T17:01:52.792Z:USER:taskMaster.c:6497:Temperature: 22.6 C
2025-10-27T17:02:25.691Z:USER:taskMaster.c:6599:Socket #1: L1N=231.7V L2N=232.2V L3N=231.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T17:03:41.984Z:INFO:active_lb.c:308:SMt:(8.0 1.0 1.0)A Free:(17.0 24.0 24.0)A ALB:(16.3 24.0 24.0)A
2025-10-27T17:13:41.917Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(22.8 22.0 24.0)A
2025-10-27T17:16:53.300Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-27T17:17:25.593Z:USER:taskMaster.c:6599:Socket #1: L1N=231.1V L2N=230.8V L3N=229.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T17:23:41.855Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 23.8)A
2025-10-27T17:31:53.753Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-27T17:32:25.500Z:USER:taskMaster.c:6599:Socket #1: L1N=231.6V L2N=232.5V L3N=231.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T17:33:41.792Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 23.0)A
2025-10-27T17:43:41.726Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-27T17:46:54.507Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-27T17:47:25.402Z:USER:taskMaster.c:6599:Socket #1: L1N=232.9V L2N=233.3V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T17:53:41.664Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.6 24.0)A
2025-10-27T18:01:54.613Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-27T18:02:25.308Z:USER:taskMaster.c:6599:Socket #1: L1N=233.8V L2N=233.0V L3N=231.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T18:03:41.601Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 23.6)A
2025-10-27T18:13:41.535Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(23.9 24.0 23.0)A
2025-10-27T18:16:55.066Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-27T18:17:25.210Z:USER:taskMaster.c:6599:Socket #1: L1N=233.1V L2N=233.8V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T18:23:41.472Z:INFO:active_lb.c:308:SMt:(2.0 2.0 2.0)A Free:(23.0 23.0 23.0)A ALB:(23.0 23.0 23.0)A
2025-10-27T18:31:55.519Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-27T18:32:25.117Z:USER:taskMaster.c:6599:Socket #1: L1N=233.2V L2N=233.7V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T18:33:41.410Z:INFO:active_lb.c:308:SMt:(3.0 2.0 2.0)A Free:(22.0 23.0 23.0)A ALB:(22.4 23.0 23.0)A
2025-10-27T18:43:32.925Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-27T18:43:32.937Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-27T18:43:41.343Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(24.0 23.0 23.0)A ALB:(24.0 23.0 23.0)A
2025-10-27T18:46:55.925Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-27T18:47:25.019Z:USER:taskMaster.c:6599:Socket #1: L1N=235.7V L2N=235.9V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T18:53:41.281Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(23.9 23.0 24.0)A
2025-10-27T19:01:56.378Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-27T19:02:24.925Z:USER:taskMaster.c:6599:Socket #1: L1N=229.3V L2N=229.8V L3N=227.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T19:03:41.218Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(24.0 22.0 23.0)A ALB:(24.0 22.2 23.6)A
2025-10-27T19:13:41.152Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-27T19:16:56.785Z:USER:taskMaster.c:6497:Temperature: 21.9 C
2025-10-27T19:17:24.828Z:USER:taskMaster.c:6599:Socket #1: L1N=235.2V L2N=235.4V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T19:23:41.089Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(22.8 23.5 24.0)A
2025-10-27T19:31:57.238Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-27T19:32:24.734Z:USER:taskMaster.c:6599:Socket #1: L1N=231.5V L2N=231.5V L3N=229.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T19:33:41.027Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(23.0 22.0 24.0)A
2025-10-27T19:43:40.960Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(22.6 23.0 24.0)A
2025-10-27T19:46:57.691Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-27T19:47:24.636Z:USER:taskMaster.c:6599:Socket #1: L1N=236.0V L2N=236.2V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T19:53:40.898Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 23.9 24.0)A
2025-10-27T20:01:58.144Z:USER:taskMaster.c:6497:Temperature: 21.9 C
2025-10-27T20:02:24.542Z:USER:taskMaster.c:6599:Socket #1: L1N=232.9V L2N=232.4V L3N=230.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T20:03:40.835Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 23.7 24.0)A
2025-10-27T20:13:40.769Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(22.8 22.8 24.0)A
2025-10-27T20:16:58.851Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-27T20:17:24.445Z:USER:taskMaster.c:6599:Socket #1: L1N=234.8V L2N=235.0V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T20:23:40.707Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(23.0 22.0 24.0)A ALB:(22.3 22.6 24.0)A
2025-10-27T20:31:59.003Z:USER:taskMaster.c:6497:Temperature: 22.0 C
2025-10-27T20:32:24.351Z:USER:taskMaster.c:6599:Socket #1: L1N=234.6V L2N=234.5V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T20:33:40.644Z:INFO:active_lb.c:308:SMt:(3.0 2.0 1.0)A Free:(22.0 23.0 24.0)A ALB:(22.0 23.6 24.0)A
2025-10-27T20:43:23.562Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-27T20:43:23.832Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-27T20:43:32.160Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-27T20:43:32.171Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-27T20:43:40.578Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(23.0 22.0 24.0)A ALB:(23.0 22.0 23.6)A
2025-10-27T20:43:40.628Z:INFO:comFaults.c:482:Reset fault status
2025-10-27T20:46:59.457Z:USER:taskMaster.c:6497:Temperature: 21.9 C
2025-10-27T20:47:24.253Z:USER:taskMaster.c:6599:Socket #1: L1N=233.4V L2N=233.4V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T20:53:40.515Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(23.0 22.0 24.0)A ALB:(23.0 21.9 24.0)A
2025-10-27T21:01:59.914Z:USER:taskMaster.c:6497:Temperature: 21.9 C
2025-10-27T21:02:24.160Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=234.2V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T21:03:40.453Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(23.6 23.0 24.0)A
2025-10-27T21:13:40.386Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-27T21:17:00.417Z:USER:taskMaster.c:6497:Temperature: 21.9 C
2025-10-27T21:17:24.062Z:USER:taskMaster.c:6599:Socket #1: L1N=233.9V L2N=234.2V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T21:23:40.324Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-27T21:32:00.820Z:USER:taskMaster.c:6497:Temperature: 21.6 C
2025-10-27T21:32:23.968Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=234.4V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T21:33:40.261Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(23.0 23.0 24.0)A
2025-10-27T21:43:40.195Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-27T21:47:01.226Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-27T21:47:23.871Z:USER:taskMaster.c:6599:Socket #1: L1N=234.0V L2N=234.4V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T21:53:40.132Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(23.9 22.0 24.0)A
2025-10-27T22:02:01.628Z:USER:taskMaster.c:6497:Temperature: 21.4 C
2025-10-27T22:02:23.777Z:USER:taskMaster.c:6599:Socket #1: L1N=232.6V L2N=233.1V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T22:03:40.066Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.8 24.0 24.0)A
2025-10-27T22:13:40.003Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.2 24.0 24.0)A
2025-10-27T22:17:02.082Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-27T22:17:23.679Z:USER:taskMaster.c:6599:Socket #1: L1N=234.9V L2N=235.1V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T22:23:39.941Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.4 24.0 24.0)A
2025-10-27T22:32:02.386Z:USER:taskMaster.c:6497:Temperature: 21.4 C
2025-10-27T22:32:23.585Z:USER:taskMaster.c:6599:Socket #1: L1N=236.7V L2N=237.6V L3N=236.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T22:33:39.875Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T22:37:14.148Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-27T22:37:14.488Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-27T22:37:14.738Z:WARNING:web_functionalit:48:Failed to parse property '2068_1'
2025-10-27T22:37:14.746Z:WARNING:web_functionalit:48:Failed to parse property '2068_2'
2025-10-27T22:37:14.761Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-10-27T22:37:15.226Z:WARNING:web_functionalit:48:Failed to parse property '8006_0'
2025-10-27T22:37:15.378Z:WARNING:web_functionalit:48:Failed to parse property '8201_0'
2025-10-27T22:37:15.386Z:WARNING:web_functionalit:48:Failed to parse property '8202_0'
2025-10-27T22:37:15.398Z:WARNING:web_functionalit:48:Failed to parse property '8203_0'
2025-10-27T22:37:15.406Z:WARNING:web_functionalit:48:Failed to parse property '8301_0'
2025-10-27T22:37:15.417Z:WARNING:web_functionalit:48:Failed to parse property '8302_0'
2025-10-27T22:37:15.527Z:WARNING:web_functionalit:48:Failed to parse property '8303_0'
2025-10-27T22:37:15.539Z:WARNING:web_functionalit:48:Failed to parse property '8101_1'
2025-10-27T22:37:15.546Z:WARNING:web_functionalit:48:Failed to parse property '8101_2'
2025-10-27T22:37:15.558Z:WARNING:web_functionalit:48:Failed to parse property '8102_1'
2025-10-27T22:37:15.566Z:WARNING:web_functionalit:48:Failed to parse property '8102_2'
2025-10-27T22:37:15.578Z:WARNING:web_functionalit:48:Failed to parse property '8103_1'
2025-10-27T22:37:15.585Z:WARNING:web_functionalit:48:Failed to parse property '8103_2'
2025-10-27T22:37:15.593Z:WARNING:web_functionalit:48:Failed to parse property '8108_1'
2025-10-27T22:37:15.621Z:WARNING:web_functionalit:48:Failed to parse property '8108_2'
2025-10-27T22:37:15.628Z:WARNING:web_functionalit:48:Failed to parse property '8107_1'
2025-10-27T22:37:15.640Z:WARNING:web_functionalit:48:Failed to parse property '8107_2'
2025-10-27T22:37:15.648Z:WARNING:web_functionalit:48:Failed to parse property '810A_1'
2025-10-27T22:37:15.656Z:WARNING:web_functionalit:48:Failed to parse property '810A_2'
2025-10-27T22:37:15.667Z:WARNING:web_functionalit:48:Failed to parse property '8109_1'
2025-10-27T22:37:15.675Z:WARNING:web_functionalit:48:Failed to parse property '8109_2'
2025-10-27T22:37:15.832Z:WARNING:web_functionalit:48:Failed to parse property '2188_0'
2025-10-27T22:37:51.328Z:INFO:web_functionali:159:Executing command: 'txerase'
2025-10-27T22:37:54.332Z:INFO:db_transaction.:181:Resetting nextToDoItem
2025-10-27T22:37:54.355Z:SECURITY:db_base.c:187:Cleared Transaction db
2025-10-27T22:37:54.363Z:INFO:db_transaction.:199:Empty transaction database
2025-10-27T22:37:54.371Z:COM:ocpp_rpc.c:715:-> [2,"50","Heartbeat",{}]
2025-10-27T22:37:54.402Z:COM:ocpp_rpc.c:1292:<- [3,"50",{"currentTime":"2025-10-27T22:37:57.518Z"}]
2025-10-27T22:37:59.003Z:WARNING:db_base.c:383:Attempted out-of-bounds search
2025-10-27T22:37:59.015Z:WARNING:db_base.c:383:Attempted out-of-bounds search
2025-10-27T22:37:59.230Z:WARNING:db_base.c:383:Attempted out-of-bounds search
2025-10-27T22:37:59.238Z:WARNING:db_base.c:383:Attempted out-of-bounds search
2025-10-27T22:38:38.449Z:WARNING:taskWebClient.c:234:Client (fd=2) disconnected (r: -0x50)
2025-10-27T22:38:38.457Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-27T22:38:38.492Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-27T22:39:26.441Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-27T22:39:26.531Z:SECURITY:taskWebClient.c:446:Received unauthorized request, so removing client
2025-10-27T22:39:26.542Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-27T22:39:26.570Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-27T22:39:28.304Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-27T22:39:28.414Z:SECURITY:taskWebClient.c:446:Received unauthorized request, so removing client
2025-10-27T22:39:28.425Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-27T22:39:28.542Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-27T22:39:30.265Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-27T22:39:30.558Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-27T22:39:30.925Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-27T22:40:16.699Z:WARNING:taskWebClient.c:234:Client (fd=2) disconnected (r: -0x0)
2025-10-27T22:40:16.707Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-27T22:40:16.812Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-27T22:43:35.976Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-27T22:43:35.988Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-27T22:43:44.394Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T22:47:06.925Z:USER:taskMaster.c:6497:Temperature: 21.2 C
2025-10-27T22:47:28.070Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=235.9V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T22:53:44.332Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T23:02:07.378Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-27T23:02:27.976Z:USER:taskMaster.c:6599:Socket #1: L1N=235.7V L2N=236.3V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T23:03:44.269Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T23:13:44.203Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T23:17:07.832Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-27T23:17:27.878Z:USER:taskMaster.c:6599:Socket #1: L1N=237.3V L2N=237.8V L3N=237.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T23:23:44.140Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T23:32:08.285Z:USER:taskMaster.c:6497:Temperature: 20.9 C
2025-10-27T23:32:27.785Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=234.2V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T23:33:44.074Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T23:43:44.011Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-27T23:47:08.691Z:USER:taskMaster.c:6497:Temperature: 20.9 C
2025-10-27T23:47:27.687Z:USER:taskMaster.c:6599:Socket #1: L1N=236.2V L2N=236.8V L3N=236.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-27T23:53:43.949Z:INFO:active_lb.c:308:SMt:(3.0 1.0 1.0)A Free:(22.0 24.0 24.0)A ALB:(22.2 24.0 24.0)A
2025-10-28T00:02:09.343Z:USER:taskMaster.c:6497:Temperature: 20.8 C
2025-10-28T00:02:27.593Z:USER:taskMaster.c:6599:Socket #1: L1N=235.0V L2N=235.5V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T00:03:43.882Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T00:13:43.820Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.4 24.0 24.0)A
2025-10-28T00:17:09.597Z:USER:taskMaster.c:6497:Temperature: 20.6 C
2025-10-28T00:17:27.496Z:USER:taskMaster.c:6599:Socket #1: L1N=235.9V L2N=236.5V L3N=236.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T00:23:43.753Z:INFO:active_lb.c:308:SMt:(3.0 1.0 1.0)A Free:(22.0 24.0 24.0)A ALB:(22.4 24.0 24.0)A
2025-10-28T00:32:10.152Z:USER:taskMaster.c:6497:Temperature: 20.6 C
2025-10-28T00:32:27.398Z:USER:taskMaster.c:6599:Socket #1: L1N=235.3V L2N=236.0V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T00:33:43.691Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T00:43:26.410Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-28T00:43:26.679Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-28T00:43:35.207Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-28T00:43:35.218Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-28T00:43:43.628Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T00:47:10.503Z:USER:taskMaster.c:6497:Temperature: 20.9 C
2025-10-28T00:47:27.304Z:USER:taskMaster.c:6599:Socket #1: L1N=236.8V L2N=237.9V L3N=237.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T00:53:43.562Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T01:02:10.960Z:USER:taskMaster.c:6497:Temperature: 21.0 C
2025-10-28T01:02:27.207Z:USER:taskMaster.c:6599:Socket #1: L1N=235.7V L2N=236.4V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T01:03:43.500Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T01:13:43.433Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T01:17:11.363Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-28T01:17:27.109Z:USER:taskMaster.c:6599:Socket #1: L1N=236.0V L2N=237.1V L3N=237.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T01:23:43.371Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 23.9 24.0)A
2025-10-28T01:32:11.816Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-28T01:32:27.015Z:USER:taskMaster.c:6599:Socket #1: L1N=237.4V L2N=237.4V L3N=237.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T01:33:43.308Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T01:43:43.242Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-28T01:47:12.269Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-28T01:47:26.917Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=234.2V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T01:53:43.179Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.1 24.0)A
2025-10-28T02:02:12.726Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-28T02:02:26.824Z:USER:taskMaster.c:6599:Socket #1: L1N=233.5V L2N=233.8V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T02:03:43.113Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(24.0 23.0 20.0)A ALB:(24.0 23.0 20.0)A
2025-10-28T02:13:43.050Z:INFO:active_lb.c:308:SMt:(2.0 3.0 5.0)A Free:(23.0 22.0 20.0)A ALB:(23.1 22.1 20.0)A
2025-10-28T02:17:13.378Z:USER:taskMaster.c:6497:Temperature: 21.0 C
2025-10-28T02:17:26.726Z:USER:taskMaster.c:6599:Socket #1: L1N=233.7V L2N=234.2V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T02:23:42.988Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(24.0 23.0 20.0)A ALB:(23.2 22.8 20.0)A
2025-10-28T02:32:13.582Z:USER:taskMaster.c:6497:Temperature: 21.2 C
2025-10-28T02:32:26.628Z:USER:taskMaster.c:6599:Socket #1: L1N=233.6V L2N=234.3V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T02:33:42.921Z:INFO:active_lb.c:308:SMt:(1.0 4.0 5.0)A Free:(24.0 21.0 20.0)A ALB:(24.0 21.4 20.0)A
2025-10-28T02:37:57.464Z:COM:ocpp_rpc.c:715:-> [2,"51","Heartbeat",{}]
2025-10-28T02:37:57.488Z:COM:ocpp_rpc.c:1292:<- [3,"51",{"currentTime":"2025-10-28T02:37:56.835Z"}]
2025-10-28T02:43:32.941Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-28T02:43:32.949Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-28T02:43:41.359Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(24.0 23.0 20.0)A ALB:(24.0 23.4 20.0)A
2025-10-28T02:47:12.187Z:USER:taskMaster.c:6497:Temperature: 21.4 C
2025-10-28T02:47:25.035Z:USER:taskMaster.c:6599:Socket #1: L1N=233.1V L2N=234.0V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T02:53:41.292Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(24.0 23.0 20.0)A ALB:(24.0 23.0 20.0)A
2025-10-28T03:02:12.542Z:USER:taskMaster.c:6497:Temperature: 21.4 C
2025-10-28T03:02:24.937Z:USER:taskMaster.c:6599:Socket #1: L1N=232.7V L2N=233.3V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T03:03:41.230Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-28T03:13:41.167Z:INFO:active_lb.c:308:SMt:(1.0 1.0 4.0)A Free:(24.0 24.0 21.0)A ALB:(24.0 24.0 20.6)A
2025-10-28T03:17:12.945Z:USER:taskMaster.c:6497:Temperature: 21.4 C
2025-10-28T03:17:24.843Z:USER:taskMaster.c:6599:Socket #1: L1N=236.4V L2N=236.9V L3N=236.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T03:23:41.101Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-28T03:32:13.449Z:USER:taskMaster.c:6497:Temperature: 21.4 C
2025-10-28T03:32:24.746Z:USER:taskMaster.c:6599:Socket #1: L1N=236.5V L2N=236.7V L3N=236.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T03:33:41.039Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-28T03:43:40.972Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-28T03:47:13.753Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-28T03:47:24.652Z:USER:taskMaster.c:6599:Socket #1: L1N=236.0V L2N=236.2V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T03:53:40.910Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-28T04:02:14.207Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-28T04:02:24.554Z:USER:taskMaster.c:6599:Socket #1: L1N=235.0V L2N=235.7V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T04:03:40.847Z:INFO:active_lb.c:308:SMt:(2.0 1.0 5.0)A Free:(23.0 24.0 20.0)A ALB:(23.0 24.0 20.0)A
2025-10-28T04:13:40.781Z:INFO:active_lb.c:308:SMt:(2.0 1.0 5.0)A Free:(23.0 24.0 20.0)A ALB:(23.0 24.0 20.0)A
2025-10-28T04:17:14.660Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-28T04:17:24.457Z:USER:taskMaster.c:6599:Socket #1: L1N=233.3V L2N=233.6V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T04:23:40.718Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-28T04:32:15.164Z:USER:taskMaster.c:6497:Temperature: 21.4 C
2025-10-28T04:32:24.363Z:USER:taskMaster.c:6599:Socket #1: L1N=234.3V L2N=234.5V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T04:33:40.656Z:INFO:active_lb.c:308:SMt:(1.0 2.0 4.0)A Free:(24.0 23.0 21.0)A ALB:(24.0 23.0 21.0)A
2025-10-28T04:43:24.179Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-28T04:43:24.453Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-28T04:43:32.171Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-28T04:43:32.183Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-28T04:43:40.589Z:INFO:active_lb.c:308:SMt:(2.0 1.0 5.0)A Free:(23.0 24.0 20.0)A ALB:(23.0 23.9 20.2)A
2025-10-28T04:47:15.519Z:USER:taskMaster.c:6497:Temperature: 21.6 C
2025-10-28T04:47:24.265Z:USER:taskMaster.c:6599:Socket #1: L1N=234.8V L2N=235.4V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T04:53:40.527Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-28T05:02:15.972Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-28T05:02:24.171Z:USER:taskMaster.c:6599:Socket #1: L1N=232.9V L2N=233.6V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T05:03:40.460Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T05:13:40.398Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T05:17:16.476Z:USER:taskMaster.c:6497:Temperature: 21.9 C
2025-10-28T05:17:24.074Z:USER:taskMaster.c:6599:Socket #1: L1N=234.5V L2N=234.8V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T05:23:40.335Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T05:32:16.878Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-28T05:32:23.980Z:USER:taskMaster.c:6599:Socket #1: L1N=235.5V L2N=235.7V L3N=235.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T05:33:40.269Z:INFO:active_lb.c:308:SMt:(5.0 1.0 1.0)A Free:(20.0 24.0 24.0)A ALB:(20.1 23.7 24.0)A
2025-10-28T05:43:40.207Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.0 24.0 23.0)A
2025-10-28T05:47:17.285Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-28T05:47:23.882Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=234.4V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T05:53:40.144Z:INFO:active_lb.c:308:SMt:(6.0 1.0 1.0)A Free:(19.0 24.0 24.0)A ALB:(19.0 24.0 24.0)A
2025-10-28T05:57:28.078Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-10-28T06:02:17.738Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-28T06:02:23.789Z:USER:taskMaster.c:6599:Socket #1: L1N=234.4V L2N=234.9V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T06:03:40.078Z:INFO:active_lb.c:308:SMt:(2.0 1.0 2.0)A Free:(23.0 24.0 23.0)A ALB:(23.0 24.0 23.0)A
2025-10-28T06:07:28.117Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-10-28T06:13:40.015Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T06:17:18.144Z:USER:taskMaster.c:6497:Temperature: 22.6 C
2025-10-28T06:17:23.691Z:USER:taskMaster.c:6599:Socket #1: L1N=233.3V L2N=233.0V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T06:17:28.050Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-10-28T06:23:39.953Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 24.0 24.0)A
2025-10-28T06:32:18.648Z:USER:taskMaster.c:6497:Temperature: 22.8 C
2025-10-28T06:32:23.597Z:USER:taskMaster.c:6599:Socket #1: L1N=233.6V L2N=234.3V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T06:33:39.886Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T06:37:54.472Z:COM:ocpp_rpc.c:715:-> [2,"52","Heartbeat",{}]
2025-10-28T06:37:54.496Z:COM:ocpp_rpc.c:1292:<- [3,"52",{"currentTime":"2025-10-28T06:37:56.148Z"}]
2025-10-28T06:43:32.898Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-28T06:43:32.910Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-28T06:43:41.316Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(20.9 24.0 23.9)A
2025-10-28T06:47:20.996Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-28T06:47:24.996Z:USER:taskMaster.c:6599:Socket #1: L1N=232.0V L2N=233.1V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T06:53:41.253Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T07:02:21.449Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-28T07:02:24.949Z:USER:taskMaster.c:6599:Socket #1: L1N=233.4V L2N=233.9V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T07:03:41.191Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T07:13:41.125Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T07:17:21.804Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-28T07:17:24.851Z:USER:taskMaster.c:6599:Socket #1: L1N=235.4V L2N=235.3V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T07:23:41.062Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T07:32:22.308Z:USER:taskMaster.c:6497:Temperature: 23.4 C
2025-10-28T07:32:24.757Z:USER:taskMaster.c:6599:Socket #1: L1N=232.9V L2N=233.0V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T07:33:41.000Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T07:43:40.933Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T07:47:22.710Z:USER:taskMaster.c:6497:Temperature: 23.6 C
2025-10-28T07:47:24.660Z:USER:taskMaster.c:6599:Socket #1: L1N=235.1V L2N=236.5V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T07:53:40.871Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(23.4 23.0 24.0)A
2025-10-28T08:02:23.167Z:USER:taskMaster.c:6497:Temperature: 23.8 C
2025-10-28T08:02:24.566Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=236.1V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T08:03:40.808Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T08:13:40.746Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-28T08:17:23.523Z:USER:taskMaster.c:6497:Temperature: 23.8 C
2025-10-28T08:17:24.472Z:USER:taskMaster.c:6599:Socket #1: L1N=235.5V L2N=235.5V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T08:23:40.679Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T08:32:23.777Z:USER:taskMaster.c:6497:Temperature: 24.1 C
2025-10-28T08:32:24.375Z:USER:taskMaster.c:6599:Socket #1: L1N=232.3V L2N=233.2V L3N=231.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T08:33:40.617Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T08:43:23.964Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-28T08:43:24.238Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-28T08:43:32.136Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-28T08:43:32.148Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-28T08:43:40.554Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-28T08:43:40.605Z:INFO:comFaults.c:482:Reset fault status
2025-10-28T08:47:24.281Z:USER:taskMaster.c:6599:Socket #1: L1N=232.0V L2N=232.9V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T08:47:24.382Z:USER:taskMaster.c:6497:Temperature: 23.8 C
2025-10-28T08:53:40.492Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(23.6 23.0 24.0)A
2025-10-28T09:02:24.183Z:USER:taskMaster.c:6599:Socket #1: L1N=235.7V L2N=236.1V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T09:02:24.835Z:USER:taskMaster.c:6497:Temperature: 23.4 C
2025-10-28T09:03:40.425Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-28T09:13:40.363Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-28T09:17:24.089Z:USER:taskMaster.c:6599:Socket #1: L1N=234.0V L2N=234.7V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T09:17:25.242Z:USER:taskMaster.c:6497:Temperature: 23.4 C
2025-10-28T09:23:40.300Z:INFO:active_lb.c:308:SMt:(-1.0 3.0 1.0)A Free:(26.0 22.0 24.0)A ALB:(24.5 22.0 24.0)A
2025-10-28T09:32:23.996Z:USER:taskMaster.c:6599:Socket #1: L1N=236.6V L2N=236.8V L3N=236.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T09:32:25.695Z:USER:taskMaster.c:6497:Temperature: 23.4 C
2025-10-28T09:33:40.238Z:INFO:active_lb.c:308:SMt:(-1.0 3.0 1.0)A Free:(26.0 22.0 24.0)A ALB:(25.8 22.0 24.0)A
2025-10-28T09:43:40.171Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.4 22.0 24.0)A
2025-10-28T09:47:23.898Z:USER:taskMaster.c:6599:Socket #1: L1N=235.0V L2N=235.2V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T09:47:26.101Z:USER:taskMaster.c:6497:Temperature: 23.9 C
2025-10-28T09:53:40.109Z:INFO:active_lb.c:308:SMt:(-1.0 3.0 1.0)A Free:(26.0 22.0 24.0)A ALB:(25.7 22.0 24.0)A
2025-10-28T10:02:23.804Z:USER:taskMaster.c:6599:Socket #1: L1N=235.1V L2N=235.4V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T10:02:26.554Z:USER:taskMaster.c:6497:Temperature: 23.9 C
2025-10-28T10:03:40.046Z:INFO:active_lb.c:308:SMt:(-1.0 3.0 1.0)A Free:(26.0 22.0 24.0)A ALB:(25.9 22.0 24.0)A
2025-10-28T10:13:39.984Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 1.0)A Free:(26.0 23.0 24.0)A ALB:(25.9 23.0 24.0)A
2025-10-28T10:17:23.707Z:USER:taskMaster.c:6599:Socket #1: L1N=236.4V L2N=236.5V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T10:17:26.960Z:USER:taskMaster.c:6497:Temperature: 24.1 C
2025-10-28T10:23:39.917Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 1.0)A Free:(26.0 23.0 24.0)A ALB:(25.5 23.0 24.0)A
2025-10-28T10:32:23.613Z:USER:taskMaster.c:6599:Socket #1: L1N=235.4V L2N=235.2V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T10:32:27.515Z:USER:taskMaster.c:6497:Temperature: 24.6 C
2025-10-28T10:33:39.855Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(25.8 23.9 24.0)A
2025-10-28T10:37:54.480Z:COM:ocpp_rpc.c:715:-> [2,"53","Heartbeat",{}]
2025-10-28T10:37:54.507Z:COM:ocpp_rpc.c:1292:<- [3,"53",{"currentTime":"2025-10-28T10:37:55.476Z"}]
2025-10-28T10:43:31.851Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-28T10:43:31.863Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-28T10:43:40.269Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(25.7 24.0 24.0)A
2025-10-28T10:47:23.996Z:USER:taskMaster.c:6599:Socket #1: L1N=236.4V L2N=236.5V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T10:47:27.898Z:USER:taskMaster.c:6497:Temperature: 24.8 C
2025-10-28T10:53:40.207Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 26.0 24.0)A
2025-10-28T11:02:23.902Z:USER:taskMaster.c:6599:Socket #1: L1N=237.8V L2N=238.3V L3N=237.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T11:02:28.351Z:USER:taskMaster.c:6497:Temperature: 25.1 C
2025-10-28T11:03:40.144Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 1.0)A Free:(26.0 27.0 24.0)A ALB:(25.6 27.0 24.0)A
2025-10-28T11:13:40.082Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.3 24.0 24.0)A
2025-10-28T11:17:23.808Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=233.8V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T11:17:28.804Z:USER:taskMaster.c:6497:Temperature: 25.5 C
2025-10-28T11:23:40.015Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.2 24.8 24.0)A
2025-10-28T11:32:23.710Z:USER:taskMaster.c:6599:Socket #1: L1N=236.8V L2N=235.8V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T11:32:29.210Z:USER:taskMaster.c:6497:Temperature: 25.4 C
2025-10-28T11:33:39.953Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(24.0 26.0 24.0)A ALB:(24.4 26.0 24.0)A
2025-10-28T11:43:39.890Z:INFO:active_lb.c:308:SMt:(-1.0 -3.0 1.0)A Free:(26.0 28.0 24.0)A ALB:(26.1 27.8 24.0)A
2025-10-28T11:47:23.617Z:USER:taskMaster.c:6599:Socket #1: L1N=236.2V L2N=236.6V L3N=236.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T11:47:29.367Z:USER:taskMaster.c:6497:Temperature: 25.4 C
2025-10-28T11:53:39.828Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 26.0 24.0)A
2025-10-28T12:02:23.523Z:USER:taskMaster.c:6599:Socket #1: L1N=236.9V L2N=237.5V L3N=237.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T12:02:30.070Z:USER:taskMaster.c:6497:Temperature: 25.4 C
2025-10-28T12:03:39.761Z:INFO:active_lb.c:308:SMt:(5.0 -1.0 1.0)A Free:(20.0 26.0 24.0)A ALB:(19.8 26.0 24.0)A
2025-10-28T12:13:39.699Z:INFO:active_lb.c:308:SMt:(6.0 -1.0 1.0)A Free:(19.0 26.0 24.0)A ALB:(19.0 25.7 24.0)A
2025-10-28T12:17:23.476Z:USER:taskMaster.c:6599:Socket #1: L1N=233.9V L2N=234.5V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T12:17:30.476Z:USER:taskMaster.c:6497:Temperature: 25.5 C
2025-10-28T12:23:39.636Z:INFO:active_lb.c:308:SMt:(6.0 1.0 1.0)A Free:(19.0 24.0 24.0)A ALB:(18.7 24.0 24.0)A
2025-10-28T12:32:23.382Z:USER:taskMaster.c:6599:Socket #1: L1N=236.9V L2N=235.8V L3N=236.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T12:32:30.929Z:USER:taskMaster.c:6497:Temperature: 25.1 C
2025-10-28T12:33:39.574Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-28T12:43:22.738Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-28T12:43:23.011Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-28T12:43:31.093Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-28T12:43:31.101Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-28T12:43:39.511Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(25.8 24.1 24.0)A
2025-10-28T12:47:23.285Z:USER:taskMaster.c:6599:Socket #1: L1N=232.7V L2N=232.8V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T12:47:31.335Z:USER:taskMaster.c:6497:Temperature: 25.2 C
2025-10-28T12:53:39.445Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.2 23.9 24.0)A
2025-10-28T13:02:23.191Z:USER:taskMaster.c:6599:Socket #1: L1N=238.0V L2N=237.7V L3N=238.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T13:02:31.742Z:USER:taskMaster.c:6497:Temperature: 25.6 C
2025-10-28T13:03:39.382Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(24.0 26.0 24.0)A ALB:(24.3 26.0 24.0)A
2025-10-28T13:13:39.320Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 26.0 24.0)A
2025-10-28T13:17:23.097Z:USER:taskMaster.c:6599:Socket #1: L1N=233.8V L2N=233.4V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T13:17:32.195Z:USER:taskMaster.c:6497:Temperature: 25.6 C
2025-10-28T13:23:39.257Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-28T13:32:23.000Z:USER:taskMaster.c:6599:Socket #1: L1N=235.4V L2N=235.6V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T13:32:32.601Z:USER:taskMaster.c:6497:Temperature: 25.6 C
2025-10-28T13:33:39.195Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(25.3 24.0 24.0)A
2025-10-28T13:43:39.128Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-28T13:47:22.906Z:USER:taskMaster.c:6599:Socket #1: L1N=234.9V L2N=236.1V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T13:47:33.156Z:USER:taskMaster.c:6497:Temperature: 25.5 C
2025-10-28T13:53:39.066Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-28T14:02:22.812Z:USER:taskMaster.c:6599:Socket #1: L1N=236.5V L2N=237.7V L3N=237.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T14:02:33.460Z:USER:taskMaster.c:6497:Temperature: 25.9 C
2025-10-28T14:03:39.003Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 1.0)A Free:(26.0 27.0 24.0)A ALB:(25.3 26.9 24.0)A
2025-10-28T14:13:38.941Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(25.8 24.0 24.0)A
2025-10-28T14:17:22.714Z:USER:taskMaster.c:6599:Socket #1: L1N=235.4V L2N=235.1V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T14:17:33.867Z:USER:taskMaster.c:6497:Temperature: 26.0 C
2025-10-28T14:23:38.878Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(25.2 24.0 24.0)A
2025-10-28T14:32:22.621Z:USER:taskMaster.c:6599:Socket #1: L1N=235.6V L2N=235.3V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T14:32:34.722Z:USER:taskMaster.c:6497:Temperature: 25.9 C
2025-10-28T14:33:38.812Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.4 24.0 24.0)A
2025-10-28T14:37:53.480Z:COM:ocpp_rpc.c:715:-> [2,"54","Heartbeat",{}]
2025-10-28T14:37:53.515Z:COM:ocpp_rpc.c:1292:<- [3,"54",{"currentTime":"2025-10-28T14:37:54.819Z"}]
2025-10-28T14:43:30.804Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-28T14:43:30.816Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-28T14:43:39.222Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.3 24.0 24.0)A
2025-10-28T14:47:23.000Z:USER:taskMaster.c:6599:Socket #1: L1N=234.3V L2N=234.7V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T14:47:35.750Z:USER:taskMaster.c:6497:Temperature: 25.9 C
2025-10-28T14:53:39.160Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(25.9 24.0 24.0)A
2025-10-28T15:02:22.906Z:USER:taskMaster.c:6599:Socket #1: L1N=232.9V L2N=232.9V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T15:02:35.804Z:USER:taskMaster.c:6497:Temperature: 25.5 C
2025-10-28T15:03:39.097Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.7 24.0 24.0)A
2025-10-28T15:13:39.035Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-28T15:17:22.808Z:USER:taskMaster.c:6599:Socket #1: L1N=234.0V L2N=234.7V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T15:17:36.410Z:USER:taskMaster.c:6497:Temperature: 25.4 C
2025-10-28T15:23:38.968Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 23.6 24.0)A
2025-10-28T15:32:22.714Z:USER:taskMaster.c:6599:Socket #1: L1N=235.4V L2N=234.9V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T15:32:37.015Z:USER:taskMaster.c:6497:Temperature: 25.4 C
2025-10-28T15:33:38.906Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T15:43:38.843Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.6 24.0 24.0)A
2025-10-28T15:47:22.621Z:USER:taskMaster.c:6599:Socket #1: L1N=233.0V L2N=232.8V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T15:47:37.468Z:USER:taskMaster.c:6497:Temperature: 25.2 C
2025-10-28T15:53:38.781Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-28T16:02:22.523Z:USER:taskMaster.c:6599:Socket #1: L1N=234.2V L2N=234.4V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T16:02:37.875Z:USER:taskMaster.c:6497:Temperature: 25.0 C
2025-10-28T16:03:38.714Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-28T16:13:38.652Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(23.9 22.0 24.0)A
2025-10-28T16:17:22.429Z:USER:taskMaster.c:6599:Socket #1: L1N=230.9V L2N=230.9V L3N=229.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T16:17:38.328Z:USER:taskMaster.c:6497:Temperature: 25.1 C
2025-10-28T16:23:38.589Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(23.0 23.0 24.0)A
2025-10-28T16:28:10.222Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-10-28T16:32:22.335Z:USER:taskMaster.c:6599:Socket #1: L1N=231.4V L2N=231.2V L3N=229.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T16:32:39.132Z:USER:taskMaster.c:6497:Temperature: 24.8 C
2025-10-28T16:33:38.527Z:INFO:active_lb.c:308:SMt:(1.0 3.0 10.0)A Free:(24.0 22.0 15.0)A ALB:(24.0 22.4 15.0)A
2025-10-28T16:38:10.160Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-10-28T16:43:21.515Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-28T16:43:21.789Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-28T16:43:30.046Z:INFO:heap_trace.c:493:free: 61832/160768 (38.5%) min: 35456 (22.1%) alloc #: 212
2025-10-28T16:43:30.054Z:INFO:heap_trace.c:495:fragm: 33.6% 4K: 13.9% free blocks: # 21 largest: 41080
2025-10-28T16:43:38.464Z:INFO:active_lb.c:308:SMt:(2.0 4.0 2.0)A Free:(23.0 21.0 23.0)A ALB:(23.1 21.4 23.0)A
2025-10-28T16:47:22.238Z:USER:taskMaster.c:6599:Socket #1: L1N=230.3V L2N=228.9V L3N=227.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T16:47:39.187Z:USER:taskMaster.c:6497:Temperature: 24.8 C
2025-10-28T16:48:10.195Z:INFO:taskLeds.c:338:Brightness set to 8%
2025-10-28T16:53:38.398Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-28T17:02:22.144Z:USER:taskMaster.c:6599:Socket #1: L1N=235.4V L2N=234.3V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T17:02:39.593Z:USER:taskMaster.c:6497:Temperature: 24.8 C
2025-10-28T17:03:38.335Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-28T17:13:38.273Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 23.8 24.0)A
2025-10-28T17:17:22.050Z:USER:taskMaster.c:6599:Socket #1: L1N=230.9V L2N=230.2V L3N=229.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T17:17:40.046Z:USER:taskMaster.c:6497:Temperature: 24.8 C
2025-10-28T17:23:38.210Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(23.0 23.0 24.0)A
2025-10-28T17:32:21.953Z:USER:taskMaster.c:6599:Socket #1: L1N=231.9V L2N=231.6V L3N=230.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T17:32:40.453Z:USER:taskMaster.c:6497:Temperature: 24.8 C
2025-10-28T17:33:38.148Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(23.0 22.0 24.0)A ALB:(23.2 21.9 24.0)A
2025-10-28T17:43:38.082Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-28T17:47:21.859Z:USER:taskMaster.c:6599:Socket #1: L1N=233.1V L2N=232.9V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T17:47:40.910Z:USER:taskMaster.c:6497:Temperature: 24.5 C
2025-10-28T17:53:38.019Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 23.8 24.0)A
2025-10-28T18:02:21.765Z:USER:taskMaster.c:6599:Socket #1: L1N=234.6V L2N=234.4V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T18:02:41.312Z:USER:taskMaster.c:6497:Temperature: 24.5 C
2025-10-28T18:03:37.957Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 24.0 24.0)A
2025-10-28T18:13:37.894Z:INFO:active_lb.c:308:SMt:(1.0 8.0 10.0)A Free:(24.0 17.0 15.0)A ALB:(24.0 16.7 19.7)A
2025-10-28T18:17:21.671Z:USER:taskMaster.c:6599:Socket #1: L1N=232.7V L2N=231.7V L3N=230.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T18:17:41.718Z:USER:taskMaster.c:6497:Temperature: 24.6 C
2025-10-28T18:23:37.828Z:INFO:active_lb.c:308:SMt:(1.0 5.0 1.0)A Free:(24.0 20.0 24.0)A ALB:(24.0 20.0 24.0)A
2025-10-28T18:27:36.070Z:INFO:taskMain.c:6230:Socket #1: Active current 0.0->16.0 due to current limit: Connector-MaxCurrent,
2025-10-28T18:27:36.070Z:INFO:taskMain.c:6230:Simplified-Mode3, ChargingProfile, Start
2025-10-28T18:27:36.156Z:INFO:taskMaster.c:4875:Socket #1: state main : CABLE_CONNECTED
2025-10-28T18:27:36.164Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_A
2025-10-28T18:27:36.171Z:INFO:taskMaster.c:4897:Socket #1: state led : CABLE_CONNECTED
2025-10-28T18:27:36.183Z:COM:ocpp_rpc.c:715:-> [2,"55","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-28T18:27:36.183Z:COM:ocpp_rpc.c:715:"Preparing"}]
2025-10-28T18:27:36.218Z:COM:ocpp_rpc.c:1292:<- [3,"55",{}]
2025-10-28T18:27:36.226Z:INFO:taskMain.c:6730:Socket #1: CPhigh 12.4 V
2025-10-28T18:27:36.234Z:INFO:taskMain.c:6735:Socket #1: CPlow 12.4 V
2025-10-28T18:27:36.242Z:INFO:taskMain.c:6740:Socket #1: PP 701 Ohm (20 A)
2025-10-28T18:27:37.152Z:INFO:taskMain.c:6730:Socket #1: CPhigh 9.3 V
2025-10-28T18:27:37.160Z:INFO:taskMain.c:6735:Socket #1: CPlow 9.3 V
2025-10-28T18:27:37.167Z:INFO:taskMain.c:1426:Socket #1: main state: CABLE_CONNECTED, CP: 9.3/0.9, no tag
2025-10-28T18:27:38.156Z:INFO:taskMaster.c:4875:Socket #1: state main : EV_CONNECTED_UNAUTHORIZED
2025-10-28T18:27:38.164Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B1
2025-10-28T18:27:39.160Z:INFO:taskMain.c:1426:Socket #1: main state: EV_CONNECTED_UNAUTHORIZED, CP: 9.3/0.9, no tag
2025-10-28T18:27:41.902Z:USER:tag.c:1620:Reader 0 Got NFC tag: 04BB29EAFD0F94
2025-10-28T18:27:41.921Z:COM:ocpp_rpc.c:715:-> [2,"56","StatusNotification",{"connectorId":0,"errorCode":"NoError","info":"I
2025-10-28T18:27:41.921Z:COM:ocpp_rpc.c:715:nfo: Charge card 04BB29EAFD0F94 detected","status":"Available"}]
2025-10-28T18:27:41.968Z:COM:ocpp_rpc.c:1292:<- [3,"56",{}]
2025-10-28T18:27:42.105Z:USER:taskMaster.c:6846:Socket #1: has reliable metervalue
2025-10-28T18:27:42.113Z:INFO:taskMaster.c:1571:1 cables attached
2025-10-28T18:27:42.152Z:INFO:taskMaster.c:4897:Socket #1: state led : AUTHORISING
2025-10-28T18:27:42.167Z:USER:tag.c:584:Tag 04BB29EAFD0F94 is authorised by white list
2025-10-28T18:27:42.203Z:USER:taskMaster.c:6846:Socket #1: has reliable metervalue
2025-10-28T18:27:42.210Z:USER:taskMaster.c:1872:Preparing 1, with cable 1
2025-10-28T18:27:42.253Z:INFO:taskMaster.c:4875:Socket #1: state main : EV_CONNECTED_AUTHORIZED
2025-10-28T18:27:42.265Z:USER:board_ng9xx.c:5059:Socket #1: lock socket motor
2025-10-28T18:27:42.363Z:INFO:taskMaster.c:7412:New charging session started, metervalue=5518267.000
2025-10-28T18:27:42.375Z:INFO:db_transaction.c:16:Added TransactionStart for socket 1 at 0x00000000 (ts: 2025-10-28 18:27:42)
2025-10-28T18:27:42.398Z:INFO:taskMaster.c:4897:Socket #1: state led : EV_CONNECTED
2025-10-28T18:27:42.457Z:INFO:taskMaster.c:6271:Socket #1: external current limit 15.9 A until 2025-10-28T23:00:00Z
2025-10-28T18:27:42.468Z:USER:taskMaster.c:6318:Socket #1: external current limit 15.9 A
2025-10-28T18:27:42.480Z:INFO:taskMain.c:6230:Socket #1: Active current 16.0->15.9 due to current limit: ChargingProfile
2025-10-28T18:27:43.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T18:27:43.269Z:INFO:taskMain.c:1424:Socket #1: main state: EV_CONNECTED_AUTHORIZED, CP: 9.3/9.3, tag: 04BB29EAFD0F94
2025-10-28T18:27:43.332Z:COM:ocpp_rpc.c:715:-> [2,"57","StartTransaction",{"timestamp":"2025-10-28T18:27:42Z","connectorId":
2025-10-28T18:27:43.332Z:COM:ocpp_rpc.c:715:1,"meterStart":5518267,"idTag":"04BB29EAFD0F94"}]
2025-10-28T18:27:43.359Z:INFO:taskMain.c:943:Socket #1: charging session status set active
2025-10-28T18:27:43.402Z:INFO:taskMaster.c:4875:Socket #1: state main : WAIT_FOR_START_METERVALUE
2025-10-28T18:27:43.414Z:INFO:taskMaster.c:4897:Socket #1: state led : CHARGING_PREPARING
2025-10-28T18:27:43.980Z:COM:ocpp_rpc.c:1292:<- [3,"57",{"transactionId":1,"idTagInfo":{"status":"Accepted","expiryDate":"203
2025-10-28T18:27:43.980Z:COM:ocpp_rpc.c:1292:0-12-31T00:00:00.000Z"}}]
2025-10-28T18:27:44.000Z:INFO:db_transaction.c:16:Updated TransactionStart for socket 1 at 0x00000000 (ts: 2025-10-28 18:27:42)
2025-10-28T18:27:44.027Z:USER:tag.c:1827:Tag 04BB29EAFD0F94 is authorised by server, white list updated
2025-10-28T18:27:44.101Z:COM:ocpp_rpc.c:715:-> [2,"58","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T18:27:44.101Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T18:27:42Z","sampledValue":[{"value":"5518.267","context":"Tra
2025-10-28T18:27:44.101Z:COM:ocpp_rpc.c:715:nsaction.Begin","unit":"kWh"}]}]}]
2025-10-28T18:27:44.171Z:COM:ocpp_rpc.c:1292:<- [3,"58",{}]
2025-10-28T18:27:44.242Z:COM:ocpp_rpc.c:715:-> [2,"59","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T18:27:44.242Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T18:27:43Z","sampledValue":[{"value":"5518.267","context":"Sam
2025-10-28T18:27:44.242Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T18:27:44.242Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T18:27:44.292Z:COM:ocpp_rpc.c:1292:<- [3,"59",{}]
2025-10-28T18:27:44.472Z:INFO:taskMain.c:1424:Socket #1: main state: WAIT_FOR_START_METERVALUE, CP: 9.3/9.3, tag: 04BB29EAFD0F
2025-10-28T18:27:44.472Z:INFO:taskMain.c:1424:94
2025-10-28T18:27:46.402Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_PRE_POWER_OFF
2025-10-28T18:27:46.453Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_OFF
2025-10-28T18:27:46.464Z:INFO:taskMaster.c:4897:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-10-28T18:27:46.472Z:COM:ocpp_rpc.c:715:-> [2,"60","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-28T18:27:46.472Z:COM:ocpp_rpc.c:715:"SuspendedEVSE"}]
2025-10-28T18:27:46.507Z:COM:ocpp_rpc.c:1292:<- [3,"60",{}]
2025-10-28T18:27:46.554Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B2
2025-10-28T18:27:47.492Z:INFO:taskMain.c:6730:Socket #1: CPhigh 6.4 V
2025-10-28T18:27:47.500Z:INFO:taskMain.c:6735:Socket #1: CPlow -11.4 V
2025-10-28T18:27:47.507Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_ON
2025-10-28T18:27:47.515Z:INFO:taskMaster.c:6553:Start logging meter values @30s.
2025-10-28T18:27:47.523Z:USER:taskMaster.c:6599:Socket #1: L1N=232.0V L2N=232.2V L3N=231.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T18:27:47.535Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T18:27:47.546Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_ON_BYPASS_ON
2025-10-28T18:27:47.558Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_C2
2025-10-28T18:27:47.566Z:INFO:taskMaster.c:4897:Socket #1: state led : CHARGING_POWER_ON
2025-10-28T18:27:47.578Z:COM:ocpp_rpc.c:715:-> [2,"61","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-28T18:27:47.578Z:COM:ocpp_rpc.c:715:"Charging"}]
2025-10-28T18:27:47.593Z:COM:ocpp_rpc.c:1292:<- [3,"61",{}]
2025-10-28T18:27:48.500Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-10-28T18:27:52.507Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-28T18:27:52.515Z:INFO:db_chargingprofi:26: socket 0
2025-10-28T18:27:52.523Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-28T18:27:52.531Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-28T18:27:52.539Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-28T18:27:52.546Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-28T18:27:52.558Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-28T18:27:52.566Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-28T18:27:52.578Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-28T18:27:52.585Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-28T18:27:52.593Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-28T18:27:52.601Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-28T18:27:52.609Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-28T18:27:52.617Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-28T18:27:52.625Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-28T18:27:52.632Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-28T18:27:52.640Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-28T18:27:52.652Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-28T18:27:52.660Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-28T18:27:52.667Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-28T18:27:52.675Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-28T18:27:52.683Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-28T18:27:52.691Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-28T18:28:17.550Z:USER:taskMaster.c:6599:Socket #1: L1N=230.6V L2N=230.5V L3N=229.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T18:28:17.562Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.5A P=10.7kW Idc=0.7mA
2025-10-28T18:28:47.484Z:INFO:taskMain.c:6798:Socket #1: reset HF switch count 1
2025-10-28T18:28:47.546Z:USER:taskMaster.c:6599:Socket #1: L1N=230.5V L2N=230.7V L3N=229.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T18:28:47.558Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.5A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-28T18:29:17.542Z:USER:taskMaster.c:6599:Socket #1: L1N=230.1V L2N=230.7V L3N=229.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T18:29:17.554Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.7kW Idc=0.7mA
2025-10-28T18:29:47.539Z:USER:taskMaster.c:6599:Socket #1: L1N=230.8V L2N=231.1V L3N=230.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T18:29:47.554Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-28T18:30:17.539Z:USER:taskMaster.c:6599:Socket #1: L1N=230.2V L2N=230.6V L3N=229.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T18:30:17.550Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.7kW Idc=0.7mA
2025-10-28T18:30:17.988Z:INFO:EVCapabilities.c:24:Socket #1 EV: #phases supported: 3
2025-10-28T18:30:47.382Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_OFF
2025-10-28T18:30:47.394Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_OFF_BYPASS_OFF
2025-10-28T18:30:47.406Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B2
2025-10-28T18:30:47.414Z:INFO:taskMaster.c:4897:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-10-28T18:30:47.421Z:COM:ocpp_rpc.c:715:-> [2,"62","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-28T18:30:47.421Z:COM:ocpp_rpc.c:715:"SuspendedEV"}]
2025-10-28T18:30:47.453Z:COM:ocpp_rpc.c:1292:<- [3,"62",{}]
2025-10-28T18:30:47.535Z:USER:taskMaster.c:6599:Socket #1: L1N=230.8V L2N=230.7V L3N=229.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T18:30:47.546Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.6A P=10.7kW Idc=0.7mA
2025-10-28T18:30:48.261Z:INFO:taskMain.c:6730:Socket #1: CPhigh 9.3 V
2025-10-28T18:30:48.453Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-10-28T18:30:59.492Z:INFO:taskMain.c:6230:Socket #1: Active current 15.9->14.3 due to current limit: Active-LoadBalancing
2025-10-28T18:30:59.558Z:INFO:taskMain.c:6746:Socket #1: PWM DC 23.8% (14.3 A)
2025-10-28T18:31:07.093Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-28T18:31:07.410Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-28T18:31:07.710Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-28T18:31:07.890Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-10-28T18:31:08.312Z:SECURITY:web_functionalit:68:Changed '2059_00' from 1761676288419 => 1761676270061
2025-10-28T18:31:13.160Z:INFO:taskMain.c:6230:Socket #1: Active current 14.3->15.9 due to current limit: ChargingProfile
2025-10-28T18:31:13.351Z:INFO:taskMain.c:6746:Socket #1: PWM DC 26.5% (15.9 A)
2025-10-28T18:31:17.027Z:WARNING:db_base.c:383:Attempted out-of-bounds search
2025-10-28T18:31:17.035Z:WARNING:db_transaction.:238:Unexpected record @0x000e11fd
2025-10-28T18:31:17.042Z:WARNING:db_base.c:383:Attempted out-of-bounds search
2025-10-28T18:31:19.105Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_WAKEUP
2025-10-28T18:31:19.113Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_E
2025-10-28T18:31:19.203Z:USER:taskMaster.c:6599:Socket #1: L1N=232.4V L2N=232.4V L3N=231.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T18:31:19.214Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T18:31:19.410Z:INFO:taskMain.c:6730:Socket #1: CPhigh 0.0 V
2025-10-28T18:31:19.417Z:INFO:taskMain.c:6735:Socket #1: CPlow 0.0 V
2025-10-28T18:31:20.089Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-10-28T18:31:23.105Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B1
2025-10-28T18:31:23.121Z:INFO:taskMain.c:6730:Socket #1: CPhigh 9.2 V
2025-10-28T18:31:23.128Z:INFO:taskMain.c:6735:Socket #1: CPlow 9.2 V
2025-10-28T18:31:23.605Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_OFF
2025-10-28T18:31:23.613Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B2
2025-10-28T18:31:24.152Z:INFO:taskMain.c:6735:Socket #1: CPlow -11.4 V
2025-10-28T18:31:24.574Z:SECURITY:web_functionalit:68:Changed '2059_00' from 1761676284638 => 1761676284766
2025-10-28T18:31:24.074Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-10-28T18:31:37.632Z:WARNING:taskWebClient.c:234:Client (fd=2) disconnected (r: -0x0)
2025-10-28T18:31:37.640Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-28T18:31:37.703Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-28T18:31:48.472Z:INFO:taskMain.c:6798:Socket #1: reset HF switch count 1
2025-10-28T18:31:48.613Z:USER:taskMaster.c:6599:Socket #1: L1N=232.3V L2N=232.8V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T18:31:48.628Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T18:32:18.613Z:USER:taskMaster.c:6599:Socket #1: L1N=233.0V L2N=232.8V L3N=231.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T18:32:18.625Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T18:32:42.960Z:USER:taskMaster.c:6497:Temperature: 25.2 C
2025-10-28T18:32:46.277Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-28T18:32:46.562Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-28T18:32:46.914Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-28T18:32:46.984Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-10-28T18:32:47.433Z:SECURITY:web_functionalit:68:Changed '2059_00' from 1761676368209 => 1761676368090
2025-10-28T18:32:49.164Z:USER:taskMaster.c:6599:Socket #1: L1N=232.7V L2N=232.6V L3N=231.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T18:32:49.175Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T18:32:49.187Z:INFO:taskMaster.c:6541:Stop logging meter values @30s.
2025-10-28T18:32:53.847Z:WARNING:taskWebClient.c:234:Client (fd=2) disconnected (r: -0x0)
2025-10-28T18:32:53.855Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-28T18:32:53.886Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-28T18:33:39.410Z:INFO:active_lb.c:308:SMt:(1.0 5.0 1.0)A Free:(24.0 20.0 24.0)A ALB:(24.0 20.0 24.0)A
2025-10-28T18:33:59.531Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-28T18:33:59.859Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-28T18:34:00.078Z:WARNING:web_functionalit:48:Failed to parse property '2068_1'
2025-10-28T18:34:00.085Z:WARNING:web_functionalit:48:Failed to parse property '2068_2'
2025-10-28T18:34:00.097Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-10-28T18:34:00.519Z:WARNING:web_functionalit:48:Failed to parse property '8006_0'
2025-10-28T18:34:00.675Z:WARNING:web_functionalit:48:Failed to parse property '8201_0'
2025-10-28T18:34:00.683Z:WARNING:web_functionalit:48:Failed to parse property '8202_0'
2025-10-28T18:34:00.691Z:WARNING:web_functionalit:48:Failed to parse property '8203_0'
2025-10-28T18:34:00.703Z:WARNING:web_functionalit:48:Failed to parse property '8301_0'
2025-10-28T18:34:00.710Z:WARNING:web_functionalit:48:Failed to parse property '8302_0'
2025-10-28T18:34:00.855Z:WARNING:web_functionalit:48:Failed to parse property '8303_0'
2025-10-28T18:34:00.863Z:WARNING:web_functionalit:48:Failed to parse property '8101_1'
2025-10-28T18:34:00.875Z:WARNING:web_functionalit:48:Failed to parse property '8101_2'
2025-10-28T18:34:00.882Z:WARNING:web_functionalit:48:Failed to parse property '8102_1'
2025-10-28T18:34:00.890Z:WARNING:web_functionalit:48:Failed to parse property '8102_2'
2025-10-28T18:34:00.902Z:WARNING:web_functionalit:48:Failed to parse property '8103_1'
2025-10-28T18:34:00.910Z:WARNING:web_functionalit:48:Failed to parse property '8103_2'
2025-10-28T18:34:00.921Z:WARNING:web_functionalit:48:Failed to parse property '8108_1'
2025-10-28T18:34:00.929Z:WARNING:web_functionalit:48:Failed to parse property '8108_2'
2025-10-28T18:34:00.937Z:WARNING:web_functionalit:48:Failed to parse property '8107_1'
2025-10-28T18:34:00.949Z:WARNING:web_functionalit:48:Failed to parse property '8107_2'
2025-10-28T18:34:00.957Z:WARNING:web_functionalit:48:Failed to parse property '810A_1'
2025-10-28T18:34:00.964Z:WARNING:web_functionalit:48:Failed to parse property '810A_2'
2025-10-28T18:34:00.976Z:WARNING:web_functionalit:48:Failed to parse property '8109_1'
2025-10-28T18:34:00.984Z:WARNING:web_functionalit:48:Failed to parse property '8109_2'
2025-10-28T18:34:01.210Z:WARNING:web_functionalit:48:Failed to parse property '2188_0'
2025-10-28T18:36:27.878Z:WARNING:taskWebClient.c:234:Client (fd=2) disconnected (r: -0x50)
2025-10-28T18:36:27.890Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-28T18:36:27.906Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-28T18:42:43.000Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T18:42:44.371Z:COM:ocpp_rpc.c:715:-> [2,"63","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T18:42:44.371Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T18:42:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T18:42:44.371Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T18:42:44.371Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T18:42:44.425Z:COM:ocpp_rpc.c:1292:<- [3,"63",{}]
2025-10-28T18:43:30.925Z:INFO:heap_trace.c:493:free: 61784/160768 (38.4%) min: 35456 (22.1%) alloc #: 214
2025-10-28T18:43:30.937Z:INFO:heap_trace.c:495:fragm: 33.5% 4K: 13.8% free blocks: # 21 largest: 41080
2025-10-28T18:43:39.343Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(24.0 21.0 24.0)A ALB:(24.0 20.8 24.0)A
2025-10-28T18:47:43.921Z:USER:taskMaster.c:6497:Temperature: 25.1 C
2025-10-28T18:47:49.070Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=234.5V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T18:47:49.082Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T18:53:39.281Z:INFO:active_lb.c:308:SMt:(1.0 5.0 1.0)A Free:(24.0 20.0 24.0)A ALB:(24.0 20.0 24.0)A
2025-10-28T18:57:43.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T18:57:43.882Z:COM:ocpp_rpc.c:715:-> [2,"64","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T18:57:43.882Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T18:57:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T18:57:43.882Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T18:57:43.882Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T18:57:43.937Z:COM:ocpp_rpc.c:1292:<- [3,"64",{}]
2025-10-28T19:02:44.324Z:USER:taskMaster.c:6497:Temperature: 25.1 C
2025-10-28T19:02:48.972Z:USER:taskMaster.c:6599:Socket #1: L1N=229.2V L2N=229.1V L3N=228.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T19:02:48.984Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T19:03:39.218Z:INFO:active_lb.c:308:SMt:(1.0 5.0 2.0)A Free:(24.0 20.0 23.0)A ALB:(24.0 20.2 23.0)A
2025-10-28T19:12:43.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T19:12:43.398Z:COM:ocpp_rpc.c:715:-> [2,"65","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T19:12:43.398Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T19:12:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T19:12:43.398Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T19:12:43.398Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T19:12:43.457Z:COM:ocpp_rpc.c:1292:<- [3,"65",{}]
2025-10-28T19:13:39.156Z:INFO:active_lb.c:308:SMt:(3.0 5.0 2.0)A Free:(22.0 20.0 23.0)A ALB:(22.4 20.2 23.0)A
2025-10-28T19:17:44.679Z:USER:taskMaster.c:6497:Temperature: 24.9 C
2025-10-28T19:17:48.878Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=233.5V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T19:17:48.890Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T19:23:39.093Z:INFO:active_lb.c:308:SMt:(1.0 4.0 2.0)A Free:(24.0 21.0 23.0)A ALB:(24.0 21.0 23.0)A
2025-10-28T19:27:43.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T19:27:43.914Z:COM:ocpp_rpc.c:715:-> [2,"66","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T19:27:43.914Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T19:27:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T19:27:43.914Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T19:27:43.914Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T19:27:43.964Z:COM:ocpp_rpc.c:1292:<- [3,"66",{}]
2025-10-28T19:28:01.718Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-28T19:28:01.726Z:INFO:db_chargingprofi:26: socket 0
2025-10-28T19:28:01.734Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-28T19:28:01.742Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-28T19:28:01.750Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-28T19:28:01.761Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-28T19:28:01.769Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-28T19:28:01.777Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-28T19:28:01.789Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-28T19:28:01.796Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-28T19:28:01.804Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-28T19:28:01.812Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-28T19:28:01.820Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-28T19:28:01.828Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-28T19:28:01.835Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-28T19:28:01.843Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-28T19:28:01.855Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-28T19:28:01.863Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-28T19:28:01.871Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-28T19:28:01.878Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-28T19:28:01.886Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-28T19:28:01.894Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-28T19:28:01.902Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-28T19:32:45.085Z:USER:taskMaster.c:6497:Temperature: 24.8 C
2025-10-28T19:32:48.785Z:USER:taskMaster.c:6599:Socket #1: L1N=234.0V L2N=233.5V L3N=232.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T19:32:48.796Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T19:33:39.027Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(24.0 21.0 24.0)A ALB:(24.0 21.0 23.4)A
2025-10-28T19:42:43.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T19:42:44.425Z:COM:ocpp_rpc.c:715:-> [2,"67","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T19:42:44.425Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T19:42:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T19:42:44.425Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T19:42:44.425Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T19:42:44.480Z:COM:ocpp_rpc.c:1292:<- [3,"67",{}]
2025-10-28T19:43:38.964Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(24.0 22.0 23.0)A ALB:(24.0 22.0 23.0)A
2025-10-28T19:47:45.441Z:USER:taskMaster.c:6497:Temperature: 24.6 C
2025-10-28T19:47:48.687Z:USER:taskMaster.c:6599:Socket #1: L1N=232.1V L2N=232.7V L3N=231.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T19:47:48.703Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T19:53:38.902Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-28T19:57:43.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T19:57:43.933Z:COM:ocpp_rpc.c:715:-> [2,"68","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T19:57:43.933Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T19:57:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T19:57:43.933Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T19:57:43.933Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T19:57:44.035Z:COM:ocpp_rpc.c:1292:<- [3,"68",{}]
2025-10-28T20:02:45.843Z:USER:taskMaster.c:6497:Temperature: 24.4 C
2025-10-28T20:02:48.593Z:USER:taskMaster.c:6599:Socket #1: L1N=232.7V L2N=234.0V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T20:02:48.605Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T20:03:38.839Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.1 24.0)A
2025-10-28T20:12:43.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T20:12:44.500Z:COM:ocpp_rpc.c:715:-> [2,"69","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T20:12:44.500Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T20:12:44Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T20:12:44.500Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T20:12:44.500Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T20:12:44.570Z:COM:ocpp_rpc.c:1292:<- [3,"69",{}]
2025-10-28T20:13:38.773Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.1 24.0)A
2025-10-28T20:17:46.250Z:USER:taskMaster.c:6497:Temperature: 24.4 C
2025-10-28T20:17:48.500Z:USER:taskMaster.c:6599:Socket #1: L1N=236.3V L2N=236.1V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T20:17:48.511Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T20:23:38.710Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(24.0 23.0 23.0)A ALB:(24.0 23.0 23.6)A
2025-10-28T20:27:43.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T20:27:44.027Z:COM:ocpp_rpc.c:715:-> [2,"70","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T20:27:44.027Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T20:27:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T20:27:44.027Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T20:27:44.027Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T20:27:44.085Z:COM:ocpp_rpc.c:1292:<- [3,"70",{}]
2025-10-28T20:28:09.285Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-28T20:28:09.296Z:INFO:db_chargingprofi:26: socket 0
2025-10-28T20:28:09.304Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-28T20:28:09.312Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-28T20:28:09.320Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-28T20:28:09.328Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-28T20:28:09.339Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-28T20:28:09.347Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-28T20:28:09.355Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-28T20:28:09.363Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-28T20:28:09.371Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-28T20:28:09.378Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-28T20:28:09.386Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-28T20:28:09.394Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-28T20:28:09.402Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-28T20:28:09.414Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-28T20:28:09.421Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-28T20:28:09.429Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-28T20:28:09.441Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-28T20:28:09.449Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-28T20:28:09.457Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-28T20:28:09.464Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-28T20:28:09.472Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-28T20:32:46.652Z:USER:taskMaster.c:6497:Temperature: 24.2 C
2025-10-28T20:32:48.402Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=234.4V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T20:32:48.414Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=1.4mA
2025-10-28T20:33:38.648Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 22.7 24.0)A
2025-10-28T20:42:43.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T20:42:43.542Z:COM:ocpp_rpc.c:715:-> [2,"71","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T20:42:43.542Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T20:42:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T20:42:43.542Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T20:42:43.542Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T20:42:43.601Z:COM:ocpp_rpc.c:1292:<- [3,"71",{}]
2025-10-28T20:43:22.390Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-28T20:43:22.664Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-28T20:43:30.167Z:INFO:heap_trace.c:493:free: 61784/160768 (38.4%) min: 35456 (22.1%) alloc #: 214
2025-10-28T20:43:30.175Z:INFO:heap_trace.c:495:fragm: 33.5% 4K: 13.8% free blocks: # 21 largest: 41080
2025-10-28T20:43:38.585Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.1 24.0 24.0)A
2025-10-28T20:43:38.632Z:INFO:comFaults.c:482:Reset fault status
2025-10-28T20:47:47.007Z:USER:taskMaster.c:6497:Temperature: 24.2 C
2025-10-28T20:47:48.308Z:USER:taskMaster.c:6599:Socket #1: L1N=234.3V L2N=234.1V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T20:47:48.320Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T20:53:38.519Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(23.2 23.3 24.0)A
2025-10-28T20:57:43.046Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T20:57:44.058Z:COM:ocpp_rpc.c:715:-> [2,"72","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T20:57:44.058Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T20:57:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T20:57:44.058Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T20:57:44.058Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T20:57:44.117Z:COM:ocpp_rpc.c:1292:<- [3,"72",{}]
2025-10-28T21:02:47.363Z:USER:taskMaster.c:6497:Temperature: 24.2 C
2025-10-28T21:02:48.214Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=234.9V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T21:02:48.226Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T21:03:38.457Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 24.0 24.0)A
2025-10-28T21:12:43.000Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T21:12:43.574Z:COM:ocpp_rpc.c:715:-> [2,"73","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T21:12:43.574Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T21:12:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T21:12:43.574Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T21:12:43.574Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T21:12:43.632Z:COM:ocpp_rpc.c:1292:<- [3,"73",{}]
2025-10-28T21:13:38.394Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-28T21:17:47.769Z:USER:taskMaster.c:6497:Temperature: 24.1 C
2025-10-28T21:17:48.117Z:USER:taskMaster.c:6599:Socket #1: L1N=233.8V L2N=234.3V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T21:17:48.128Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T21:23:38.332Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-28T21:27:43.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T21:27:44.101Z:COM:ocpp_rpc.c:715:-> [2,"74","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T21:27:44.101Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T21:27:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T21:27:44.101Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T21:27:44.101Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T21:27:44.167Z:COM:ocpp_rpc.c:1292:<- [3,"74",{}]
2025-10-28T21:28:16.855Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-28T21:28:16.863Z:INFO:db_chargingprofi:26: socket 0
2025-10-28T21:28:16.871Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-28T21:28:16.878Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-28T21:28:16.886Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-28T21:28:16.898Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-28T21:28:16.910Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-28T21:28:16.917Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-28T21:28:16.925Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-28T21:28:16.933Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-28T21:28:16.941Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-28T21:28:16.949Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-28T21:28:16.957Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-28T21:28:16.964Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-28T21:28:16.972Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-28T21:28:16.984Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-28T21:28:16.992Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-28T21:28:17.000Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-28T21:28:17.011Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-28T21:28:17.019Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-28T21:28:17.027Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-28T21:28:17.035Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-28T21:28:17.042Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-28T21:32:48.023Z:USER:taskMaster.c:6599:Socket #1: L1N=237.1V L2N=236.9V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T21:32:48.035Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T21:32:48.171Z:USER:taskMaster.c:6497:Temperature: 23.9 C
2025-10-28T21:33:38.269Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-28T21:42:43.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T21:42:43.625Z:COM:ocpp_rpc.c:715:-> [2,"75","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T21:42:43.625Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T21:42:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T21:42:43.625Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T21:42:43.625Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T21:42:43.691Z:COM:ocpp_rpc.c:1292:<- [3,"75",{}]
2025-10-28T21:43:38.203Z:INFO:active_lb.c:308:SMt:(2.0 1.0 2.0)A Free:(23.0 24.0 23.0)A ALB:(23.0 24.0 23.1)A
2025-10-28T21:47:47.929Z:USER:taskMaster.c:6599:Socket #1: L1N=234.2V L2N=234.3V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T21:47:47.941Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T21:47:48.527Z:USER:taskMaster.c:6497:Temperature: 23.5 C
2025-10-28T21:53:38.140Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T21:57:43.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T21:57:44.156Z:COM:ocpp_rpc.c:715:-> [2,"76","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T21:57:44.156Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T21:57:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T21:57:44.156Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T21:57:44.156Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T21:57:44.203Z:COM:ocpp_rpc.c:1292:<- [3,"76",{}]
2025-10-28T22:02:47.832Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=234.5V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T22:02:47.843Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T22:02:48.933Z:USER:taskMaster.c:6497:Temperature: 23.4 C
2025-10-28T22:03:38.078Z:INFO:active_lb.c:308:SMt:(1.0 6.0 1.0)A Free:(24.0 19.0 24.0)A ALB:(24.0 19.0 24.0)A
2025-10-28T22:12:43.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T22:12:44.660Z:COM:ocpp_rpc.c:715:-> [2,"77","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T22:12:44.660Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T22:12:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T22:12:44.660Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T22:12:44.660Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T22:12:44.718Z:COM:ocpp_rpc.c:1292:<- [3,"77",{}]
2025-10-28T22:13:38.011Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T22:17:47.738Z:USER:taskMaster.c:6599:Socket #1: L1N=232.1V L2N=232.0V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T22:17:47.750Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T22:17:49.289Z:USER:taskMaster.c:6497:Temperature: 23.2 C
2025-10-28T22:23:37.949Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T22:27:43.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T22:27:44.171Z:COM:ocpp_rpc.c:715:-> [2,"78","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T22:27:44.171Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T22:27:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T22:27:44.171Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T22:27:44.171Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T22:27:44.265Z:COM:ocpp_rpc.c:1292:<- [3,"78",{}]
2025-10-28T22:28:24.421Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-28T22:28:24.433Z:INFO:db_chargingprofi:26: socket 0
2025-10-28T22:28:24.441Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-28T22:28:24.449Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-28T22:28:24.457Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-28T22:28:24.464Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-28T22:28:24.476Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-28T22:28:24.484Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-28T22:28:24.492Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-28T22:28:24.500Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-28T22:28:24.507Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-28T22:28:24.515Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-28T22:28:24.523Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-28T22:28:24.531Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-28T22:28:24.539Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-28T22:28:24.550Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-28T22:28:24.558Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-28T22:28:24.566Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-28T22:28:24.578Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-28T22:28:24.585Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-28T22:28:24.593Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-28T22:28:24.601Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-28T22:28:24.609Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-28T22:32:47.640Z:USER:taskMaster.c:6599:Socket #1: L1N=233.2V L2N=233.4V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T22:32:47.652Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T22:32:49.691Z:USER:taskMaster.c:6497:Temperature: 23.2 C
2025-10-28T22:33:37.886Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T22:42:43.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T22:42:43.718Z:COM:ocpp_rpc.c:715:-> [2,"79","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T22:42:43.718Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T22:42:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T22:42:43.718Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T22:42:43.718Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T22:42:43.773Z:COM:ocpp_rpc.c:1292:<- [3,"79",{}]
2025-10-28T22:43:29.406Z:INFO:heap_trace.c:493:free: 61784/160768 (38.4%) min: 35456 (22.1%) alloc #: 214
2025-10-28T22:43:29.414Z:INFO:heap_trace.c:495:fragm: 33.5% 4K: 13.8% free blocks: # 21 largest: 41080
2025-10-28T22:43:37.824Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T22:47:47.546Z:USER:taskMaster.c:6599:Socket #1: L1N=233.6V L2N=233.7V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T22:47:47.558Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T22:47:50.097Z:USER:taskMaster.c:6497:Temperature: 23.0 C
2025-10-28T22:53:37.757Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T22:57:43.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T22:57:44.257Z:COM:ocpp_rpc.c:715:-> [2,"80","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T22:57:44.257Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T22:57:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T22:57:44.257Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T22:57:44.257Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T22:57:44.316Z:COM:ocpp_rpc.c:1292:<- [3,"80",{}]
2025-10-28T23:00:00.070Z:INFO:taskMaster.c:6271:Socket #1: external current limit 15.9 A until 2025-10-29T23:00:00Z
2025-10-28T23:00:00.082Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-28T23:00:00.093Z:INFO:db_chargingprofi:26: socket 0
2025-10-28T23:00:00.101Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-28T23:00:00.109Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-28T23:00:00.117Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-28T23:00:00.125Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-28T23:00:00.136Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-28T23:00:00.144Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-28T23:00:00.152Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-28T23:00:00.160Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-28T23:00:00.167Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-28T23:00:00.175Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-28T23:00:00.183Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-28T23:00:00.195Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-28T23:00:00.199Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-28T23:00:00.210Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-28T23:00:00.218Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-28T23:00:00.226Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-28T23:00:00.238Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-28T23:00:00.246Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-28T23:00:00.253Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-28T23:00:00.261Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-28T23:00:00.269Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-28T23:02:47.449Z:USER:taskMaster.c:6599:Socket #1: L1N=232.6V L2N=232.3V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T23:02:47.464Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T23:02:50.902Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-28T23:03:37.695Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T23:12:43.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T23:12:43.773Z:COM:ocpp_rpc.c:715:-> [2,"81","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T23:12:43.773Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T23:12:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T23:12:43.773Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T23:12:43.773Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T23:12:43.820Z:COM:ocpp_rpc.c:1292:<- [3,"81",{}]
2025-10-28T23:13:37.632Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.9 24.0 24.0)A
2025-10-28T23:17:47.355Z:USER:taskMaster.c:6599:Socket #1: L1N=235.2V L2N=235.1V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T23:17:47.367Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T23:17:51.253Z:USER:taskMaster.c:6497:Temperature: 23.4 C
2025-10-28T23:23:37.570Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T23:27:43.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T23:27:44.273Z:COM:ocpp_rpc.c:715:-> [2,"82","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T23:27:44.273Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T23:27:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T23:27:44.273Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T23:27:44.273Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T23:27:44.328Z:COM:ocpp_rpc.c:1292:<- [3,"82",{}]
2025-10-28T23:32:47.261Z:USER:taskMaster.c:6599:Socket #1: L1N=236.6V L2N=236.6V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T23:32:47.273Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T23:32:51.660Z:USER:taskMaster.c:6497:Temperature: 23.5 C
2025-10-28T23:33:37.503Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T23:42:43.046Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T23:42:43.781Z:COM:ocpp_rpc.c:715:-> [2,"83","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T23:42:43.781Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T23:42:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T23:42:43.781Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T23:42:43.781Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T23:42:43.839Z:COM:ocpp_rpc.c:1292:<- [3,"83",{}]
2025-10-28T23:43:37.441Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T23:47:47.164Z:USER:taskMaster.c:6599:Socket #1: L1N=237.1V L2N=237.2V L3N=237.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-28T23:47:47.175Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-28T23:47:52.015Z:USER:taskMaster.c:6497:Temperature: 23.8 C
2025-10-28T23:53:37.378Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-28T23:57:43.000Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-28T23:57:43.304Z:COM:ocpp_rpc.c:715:-> [2,"84","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-28T23:57:43.304Z:COM:ocpp_rpc.c:715:stamp":"2025-10-28T23:57:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-28T23:57:43.304Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-28T23:57:43.304Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-28T23:57:43.363Z:COM:ocpp_rpc.c:1292:<- [3,"84",{}]
2025-10-29T00:00:07.640Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-29T00:00:07.648Z:INFO:db_chargingprofi:26: socket 0
2025-10-29T00:00:07.656Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-29T00:00:07.664Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-29T00:00:07.671Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-29T00:00:07.683Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-29T00:00:07.691Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-29T00:00:07.699Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-29T00:00:07.710Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-29T00:00:07.718Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-29T00:00:07.726Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-29T00:00:07.734Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-29T00:00:07.742Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-29T00:00:07.750Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-29T00:00:07.757Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-29T00:00:07.765Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-29T00:00:07.777Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-29T00:00:07.785Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-29T00:00:07.792Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-29T00:00:07.800Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-29T00:00:07.808Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-29T00:00:07.816Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-29T00:00:07.824Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-29T00:02:47.070Z:USER:taskMaster.c:6599:Socket #1: L1N=234.2V L2N=234.9V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T00:02:47.082Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T00:02:52.417Z:USER:taskMaster.c:6497:Temperature: 23.6 C
2025-10-29T00:03:37.312Z:INFO:active_lb.c:308:SMt:(8.0 1.0 1.0)A Free:(17.0 24.0 24.0)A ALB:(17.5 24.0 24.0)A
2025-10-29T00:12:43.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T00:12:43.828Z:COM:ocpp_rpc.c:715:-> [2,"85","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-29T00:12:43.828Z:COM:ocpp_rpc.c:715:stamp":"2025-10-29T00:12:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-29T00:12:43.828Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-29T00:12:43.828Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-29T00:12:43.871Z:COM:ocpp_rpc.c:1292:<- [3,"85",{}]
2025-10-29T00:13:37.250Z:INFO:active_lb.c:308:SMt:(7.0 1.0 1.0)A Free:(18.0 24.0 24.0)A ALB:(18.0 24.0 24.0)A
2025-10-29T00:17:46.972Z:USER:taskMaster.c:6599:Socket #1: L1N=235.4V L2N=236.2V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T00:17:46.988Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T00:17:52.824Z:USER:taskMaster.c:6497:Temperature: 23.5 C
2025-10-29T00:23:37.187Z:INFO:active_lb.c:308:SMt:(9.0 1.0 1.0)A Free:(16.0 24.0 24.0)A ALB:(18.1 24.0 24.0)A
2025-10-29T00:27:43.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T00:27:44.328Z:COM:ocpp_rpc.c:715:-> [2,"86","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-29T00:27:44.328Z:COM:ocpp_rpc.c:715:stamp":"2025-10-29T00:27:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-29T00:27:44.328Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-29T00:27:44.328Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-29T00:27:44.386Z:COM:ocpp_rpc.c:1292:<- [3,"86",{}]
2025-10-29T00:32:46.878Z:USER:taskMaster.c:6599:Socket #1: L1N=233.4V L2N=233.2V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T00:32:46.890Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T00:32:53.179Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-29T00:33:37.125Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T00:42:43.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T00:42:43.851Z:COM:ocpp_rpc.c:715:-> [2,"87","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-29T00:42:43.851Z:COM:ocpp_rpc.c:715:stamp":"2025-10-29T00:42:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-29T00:42:43.851Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-29T00:42:43.851Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-29T00:42:43.917Z:COM:ocpp_rpc.c:1292:<- [3,"87",{}]
2025-10-29T00:43:20.613Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-29T00:43:20.886Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-29T00:43:28.640Z:INFO:heap_trace.c:493:free: 61784/160768 (38.4%) min: 35456 (22.1%) alloc #: 214
2025-10-29T00:43:28.652Z:INFO:heap_trace.c:495:fragm: 33.5% 4K: 13.8% free blocks: # 21 largest: 41080
2025-10-29T00:43:37.058Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 24.0 24.0)A
2025-10-29T00:47:46.785Z:USER:taskMaster.c:6599:Socket #1: L1N=233.3V L2N=233.1V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T00:47:46.796Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T00:47:53.582Z:USER:taskMaster.c:6497:Temperature: 23.2 C
2025-10-29T00:53:36.996Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T00:57:43.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T00:57:43.371Z:COM:ocpp_rpc.c:715:-> [2,"88","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-29T00:57:43.371Z:COM:ocpp_rpc.c:715:stamp":"2025-10-29T00:57:43Z","sampledValue":[{"value":"5518.796","context":"Sam
2025-10-29T00:57:43.371Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-29T00:57:43.371Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-29T00:57:43.425Z:COM:ocpp_rpc.c:1292:<- [3,"88",{}]
2025-10-29T01:00:15.207Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-29T01:00:15.214Z:INFO:db_chargingprofi:26: socket 0
2025-10-29T01:00:15.222Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-29T01:00:15.234Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-29T01:00:15.242Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-29T01:00:15.250Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-29T01:00:15.261Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-29T01:00:15.269Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-29T01:00:15.277Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-29T01:00:15.285Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-29T01:00:15.292Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-29T01:00:15.300Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-29T01:00:15.308Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-29T01:00:15.316Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-29T01:00:15.324Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-29T01:00:15.335Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-29T01:00:15.343Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-29T01:00:15.351Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-29T01:00:15.363Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-29T01:00:15.371Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-29T01:00:15.378Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-29T01:00:15.386Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-29T01:00:15.394Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-29T01:02:40.890Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_ON
2025-10-29T01:02:40.898Z:INFO:taskMaster.c:6553:Start logging meter values @30s.
2025-10-29T01:02:40.906Z:USER:taskMaster.c:6599:Socket #1: L1N=233.5V L2N=233.6V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:02:40.917Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T01:02:40.929Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_ON_BYPASS_ON
2025-10-29T01:02:40.941Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_C2
2025-10-29T01:02:40.949Z:INFO:taskMaster.c:4897:Socket #1: state led : CHARGING_POWER_ON
2025-10-29T01:02:40.960Z:COM:ocpp_rpc.c:715:-> [2,"89","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-29T01:02:40.960Z:COM:ocpp_rpc.c:715:"Charging"}]
2025-10-29T01:02:40.992Z:COM:ocpp_rpc.c:1292:<- [3,"89",{}]
2025-10-29T01:02:41.617Z:INFO:taskMain.c:6730:Socket #1: CPhigh 6.3 V
2025-10-29T01:02:41.906Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-10-29T01:02:53.988Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-29T01:03:10.937Z:USER:taskMaster.c:6599:Socket #1: L1N=231.6V L2N=231.8V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:03:10.949Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.8kW Idc=0.7mA
2025-10-29T01:03:36.933Z:INFO:active_lb.c:308:SMt:(16.0 17.0 16.0)A Free:(9.0 8.0 9.0)A ALB:(26.6 25.9 26.6)A
2025-10-29T01:03:40.890Z:INFO:taskMain.c:6798:Socket #1: reset HF switch count 1
2025-10-29T01:03:40.933Z:USER:taskMaster.c:6599:Socket #1: L1N=231.4V L2N=231.7V L3N=231.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:03:40.945Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-29T01:04:10.929Z:USER:taskMaster.c:6599:Socket #1: L1N=231.2V L2N=231.6V L3N=231.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:04:10.941Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.5A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-29T01:04:40.925Z:USER:taskMaster.c:6599:Socket #1: L1N=231.1V L2N=231.6V L3N=231.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:04:40.937Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-29T01:05:10.921Z:USER:taskMaster.c:6599:Socket #1: L1N=231.3V L2N=231.6V L3N=231.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:05:10.933Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-29T01:05:40.917Z:USER:taskMaster.c:6599:Socket #1: L1N=231.3V L2N=231.3V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:05:40.933Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-29T01:06:10.917Z:USER:taskMaster.c:6599:Socket #1: L1N=231.4V L2N=231.6V L3N=231.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:06:10.929Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-29T01:06:40.914Z:USER:taskMaster.c:6599:Socket #1: L1N=231.5V L2N=231.8V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:06:40.925Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-29T01:07:10.910Z:USER:taskMaster.c:6599:Socket #1: L1N=231.6V L2N=231.9V L3N=231.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:07:10.921Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-29T01:07:40.906Z:USER:taskMaster.c:6599:Socket #1: L1N=231.5V L2N=231.9V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:07:40.917Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-29T01:07:40.929Z:INFO:taskMaster.c:6541:Stop logging meter values @30s.
2025-10-29T01:09:34.394Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_OFF
2025-10-29T01:09:34.406Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_OFF_BYPASS_OFF
2025-10-29T01:09:34.414Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B2
2025-10-29T01:09:34.425Z:INFO:taskMaster.c:4897:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-10-29T01:09:34.433Z:COM:ocpp_rpc.c:715:-> [2,"90","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-29T01:09:34.433Z:COM:ocpp_rpc.c:715:"SuspendedEV"}]
2025-10-29T01:09:34.457Z:COM:ocpp_rpc.c:1292:<- [3,"90",{}]
2025-10-29T01:09:34.953Z:INFO:taskMain.c:6730:Socket #1: CPhigh 9.3 V
2025-10-29T01:09:35.453Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-10-29T01:10:34.386Z:INFO:taskMain.c:6798:Socket #1: reset HF switch count 1
2025-10-29T01:12:43.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T01:12:43.878Z:COM:ocpp_rpc.c:715:-> [2,"91","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-29T01:12:43.878Z:COM:ocpp_rpc.c:715:stamp":"2025-10-29T01:12:43Z","sampledValue":[{"value":"5520.027","context":"Sam
2025-10-29T01:12:43.878Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-29T01:12:43.878Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-29T01:12:43.937Z:COM:ocpp_rpc.c:1292:<- [3,"91",{}]
2025-10-29T01:13:36.871Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T01:15:11.359Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_ON
2025-10-29T01:15:11.367Z:INFO:taskMaster.c:6553:Start logging meter values @30s.
2025-10-29T01:15:11.378Z:USER:taskMaster.c:6599:Socket #1: L1N=233.3V L2N=233.4V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:15:11.390Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T01:15:11.402Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_ON_BYPASS_ON
2025-10-29T01:15:11.410Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_C2
2025-10-29T01:15:11.417Z:INFO:taskMaster.c:4897:Socket #1: state led : CHARGING_POWER_ON
2025-10-29T01:15:11.429Z:COM:ocpp_rpc.c:715:-> [2,"92","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-29T01:15:11.429Z:COM:ocpp_rpc.c:715:"Charging"}]
2025-10-29T01:15:11.453Z:COM:ocpp_rpc.c:1292:<- [3,"92",{}]
2025-10-29T01:15:11.746Z:INFO:taskMain.c:6730:Socket #1: CPhigh 6.3 V
2025-10-29T01:15:12.375Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-10-29T01:15:41.406Z:USER:taskMaster.c:6599:Socket #1: L1N=231.8V L2N=231.8V L3N=231.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:15:41.417Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-29T01:16:11.359Z:INFO:taskMain.c:6798:Socket #1: reset HF switch count 1
2025-10-29T01:16:11.402Z:USER:taskMaster.c:6599:Socket #1: L1N=231.4V L2N=231.4V L3N=231.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:16:11.414Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-29T01:16:41.398Z:USER:taskMaster.c:6599:Socket #1: L1N=231.2V L2N=231.1V L3N=231.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:16:41.414Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.8kW Idc=0.7mA
2025-10-29T01:17:11.398Z:USER:taskMaster.c:6599:Socket #1: L1N=231.5V L2N=231.3V L3N=231.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:17:11.410Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.6A P=10.8kW Idc=0.7mA
2025-10-29T01:17:41.394Z:USER:taskMaster.c:6599:Socket #1: L1N=231.7V L2N=231.6V L3N=231.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:17:41.406Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-29T01:17:54.343Z:USER:taskMaster.c:6497:Temperature: 24.4 C
2025-10-29T01:18:11.390Z:USER:taskMaster.c:6599:Socket #1: L1N=231.4V L2N=231.3V L3N=231.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:18:11.402Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.8kW Idc=0.7mA
2025-10-29T01:18:41.386Z:USER:taskMaster.c:6599:Socket #1: L1N=231.7V L2N=231.5V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:18:41.398Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.8kW Idc=0.7mA
2025-10-29T01:19:11.382Z:USER:taskMaster.c:6599:Socket #1: L1N=231.9V L2N=231.8V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:19:11.394Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-29T01:19:41.382Z:USER:taskMaster.c:6599:Socket #1: L1N=231.9V L2N=232.2V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:19:41.394Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-29T01:20:11.378Z:USER:taskMaster.c:6599:Socket #1: L1N=231.9V L2N=232.0V L3N=232.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:20:11.394Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-29T01:20:11.406Z:INFO:taskMaster.c:6541:Stop logging meter values @30s.
2025-10-29T01:23:36.804Z:INFO:active_lb.c:308:SMt:(16.0 17.0 16.0)A Free:(9.0 8.0 9.0)A ALB:(24.6 23.6 24.6)A
2025-10-29T01:27:43.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T01:27:44.394Z:COM:ocpp_rpc.c:715:-> [2,"93","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-29T01:27:44.394Z:COM:ocpp_rpc.c:715:stamp":"2025-10-29T01:27:43Z","sampledValue":[{"value":"5522.283","context":"Sam
2025-10-29T01:27:44.394Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-29T01:27:44.394Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-29T01:27:44.437Z:COM:ocpp_rpc.c:1292:<- [3,"93",{}]
2025-10-29T01:30:47.609Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_OFF
2025-10-29T01:30:47.621Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_OFF_BYPASS_OFF
2025-10-29T01:30:47.628Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B2
2025-10-29T01:30:47.640Z:INFO:taskMaster.c:4897:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-10-29T01:30:47.648Z:COM:ocpp_rpc.c:715:-> [2,"94","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-29T01:30:47.648Z:COM:ocpp_rpc.c:715:"SuspendedEV"}]
2025-10-29T01:30:47.671Z:COM:ocpp_rpc.c:1292:<- [3,"94",{}]
2025-10-29T01:30:48.546Z:INFO:taskMain.c:6730:Socket #1: CPhigh 9.3 V
2025-10-29T01:30:48.687Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-10-29T01:31:47.621Z:INFO:taskMain.c:6798:Socket #1: reset HF switch count 1
2025-10-29T01:32:54.746Z:USER:taskMaster.c:6497:Temperature: 26.9 C
2025-10-29T01:33:36.742Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T01:35:11.281Z:USER:taskMaster.c:6599:Socket #1: L1N=233.9V L2N=233.9V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:35:11.296Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T01:42:43.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T01:42:43.890Z:COM:ocpp_rpc.c:715:-> [2,"95","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-29T01:42:43.890Z:COM:ocpp_rpc.c:715:stamp":"2025-10-29T01:42:43Z","sampledValue":[{"value":"5522.836","context":"Sam
2025-10-29T01:42:43.890Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-29T01:42:43.890Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-29T01:42:43.949Z:COM:ocpp_rpc.c:1292:<- [3,"95",{}]
2025-10-29T01:43:36.679Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T01:47:55.101Z:USER:taskMaster.c:6497:Temperature: 25.4 C
2025-10-29T01:50:11.187Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=234.1V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:50:11.199Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T01:53:36.617Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T01:57:04.843Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_ON
2025-10-29T01:57:04.855Z:INFO:taskMaster.c:6553:Start logging meter values @30s.
2025-10-29T01:57:04.863Z:USER:taskMaster.c:6599:Socket #1: L1N=234.8V L2N=234.7V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:57:04.875Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T01:57:04.886Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_ON_BYPASS_ON
2025-10-29T01:57:04.894Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_C2
2025-10-29T01:57:04.906Z:INFO:taskMaster.c:4897:Socket #1: state led : CHARGING_POWER_ON
2025-10-29T01:57:04.914Z:COM:ocpp_rpc.c:715:-> [2,"96","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-29T01:57:04.914Z:COM:ocpp_rpc.c:715:"Charging"}]
2025-10-29T01:57:04.937Z:COM:ocpp_rpc.c:1292:<- [3,"96",{}]
2025-10-29T01:57:05.132Z:INFO:taskMain.c:6730:Socket #1: CPhigh 6.3 V
2025-10-29T01:57:05.871Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-10-29T01:57:34.890Z:USER:taskMaster.c:6599:Socket #1: L1N=233.1V L2N=233.2V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:57:34.902Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-10-29T01:57:43.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T01:57:44.414Z:COM:ocpp_rpc.c:715:-> [2,"97","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-29T01:57:44.414Z:COM:ocpp_rpc.c:715:stamp":"2025-10-29T01:57:43Z","sampledValue":[{"value":"5522.945","context":"Sam
2025-10-29T01:57:44.414Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-29T01:57:44.414Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-29T01:57:44.472Z:COM:ocpp_rpc.c:1292:<- [3,"97",{}]
2025-10-29T01:58:04.855Z:INFO:taskMain.c:6798:Socket #1: reset HF switch count 1
2025-10-29T01:58:04.886Z:USER:taskMaster.c:6599:Socket #1: L1N=233.0V L2N=233.0V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:58:04.898Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-10-29T01:58:34.886Z:USER:taskMaster.c:6599:Socket #1: L1N=232.8V L2N=233.0V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:58:34.898Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-10-29T01:59:04.882Z:USER:taskMaster.c:6599:Socket #1: L1N=232.6V L2N=232.8V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:59:04.894Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.4A P=10.8kW Idc=0.7mA
2025-10-29T01:59:34.878Z:USER:taskMaster.c:6599:Socket #1: L1N=232.8V L2N=233.2V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T01:59:34.890Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-10-29T02:00:04.875Z:USER:taskMaster.c:6599:Socket #1: L1N=232.7V L2N=232.9V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T02:00:04.886Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.4A P=10.8kW Idc=0.7mA
2025-10-29T02:00:22.777Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-29T02:00:22.785Z:INFO:db_chargingprofi:26: socket 0
2025-10-29T02:00:22.792Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-29T02:00:22.804Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-29T02:00:22.812Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-29T02:00:22.820Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-29T02:00:22.832Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-29T02:00:22.839Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-29T02:00:22.847Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-29T02:00:22.855Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-29T02:00:22.863Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-29T02:00:22.871Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-29T02:00:22.878Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-29T02:00:22.886Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-29T02:00:22.894Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-29T02:00:22.906Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-29T02:00:22.914Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-29T02:00:22.921Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-29T02:00:22.933Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-29T02:00:22.941Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-29T02:00:22.949Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-29T02:00:22.957Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-29T02:00:22.964Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-29T02:00:34.871Z:USER:taskMaster.c:6599:Socket #1: L1N=233.0V L2N=233.2V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T02:00:34.882Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-10-29T02:01:04.867Z:USER:taskMaster.c:6599:Socket #1: L1N=233.0V L2N=233.1V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T02:01:04.882Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.4A P=10.8kW Idc=0.8mA
2025-10-29T02:01:34.867Z:USER:taskMaster.c:6599:Socket #1: L1N=232.9V L2N=233.1V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T02:01:34.878Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-10-29T02:02:04.863Z:USER:taskMaster.c:6599:Socket #1: L1N=233.1V L2N=233.2V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T02:02:04.875Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.4A P=10.9kW Idc=0.7mA
2025-10-29T02:02:04.886Z:INFO:taskMaster.c:6541:Stop logging meter values @30s.
2025-10-29T02:02:55.507Z:USER:taskMaster.c:6497:Temperature: 25.4 C
2025-10-29T02:03:36.554Z:INFO:active_lb.c:308:SMt:(16.0 17.0 20.0)A Free:(9.0 8.0 5.0)A ALB:(24.6 23.6 20.4)A
2025-10-29T02:06:46.539Z:INFO:taskMain.c:6230:Socket #1: Active current 15.9->15.7 due to current limit: Active-LoadBalancing
2025-10-29T02:06:46.550Z:INFO:taskMain.c:5841:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->26.1)
2025-10-29T02:06:46.582Z:INFO:taskMaster.c:4897:Socket #1: state led : LOADBALANCING_LIMITED
2025-10-29T02:06:58.539Z:INFO:taskMain.c:6230:Socket #1: Active current 15.7->15.9 due to current limit: ChargingProfile
2025-10-29T02:06:58.582Z:INFO:taskMaster.c:4897:Socket #1: state led : CHARGING_POWER_ON
2025-10-29T02:12:43.046Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T02:12:43.937Z:COM:ocpp_rpc.c:715:-> [2,"98","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"time
2025-10-29T02:12:43.937Z:COM:ocpp_rpc.c:715:stamp":"2025-10-29T02:12:43Z","sampledValue":[{"value":"5525.658","context":"Sam
2025-10-29T02:12:43.937Z:COM:ocpp_rpc.c:715:ple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","u
2025-10-29T02:12:43.937Z:COM:ocpp_rpc.c:715:nit":"kWh"}]}]}]
2025-10-29T02:12:43.996Z:COM:ocpp_rpc.c:1292:<- [3,"98",{}]
2025-10-29T02:13:36.488Z:INFO:active_lb.c:308:SMt:(16.0 17.0 20.0)A Free:(9.0 8.0 5.0)A ALB:(24.5 23.6 20.5)A
2025-10-29T02:15:23.527Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_OFF
2025-10-29T02:15:23.542Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_OFF_BYPASS_OFF
2025-10-29T02:15:23.554Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B2
2025-10-29T02:15:23.562Z:INFO:taskMaster.c:4897:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-10-29T02:15:23.570Z:COM:ocpp_rpc.c:715:-> [2,"99","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-29T02:15:23.570Z:COM:ocpp_rpc.c:715:"SuspendedEV"}]
2025-10-29T02:15:23.601Z:COM:ocpp_rpc.c:1292:<- [3,"99",{}]
2025-10-29T02:15:23.625Z:INFO:taskMain.c:6730:Socket #1: CPhigh 9.3 V
2025-10-29T02:15:24.566Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-10-29T02:15:34.484Z:INFO:taskMain.c:6230:Socket #1: Active current 15.9->14.3 due to current limit: Active-LoadBalancing
2025-10-29T02:15:34.664Z:INFO:taskMain.c:6746:Socket #1: PWM DC 23.8% (14.3 A)
2025-10-29T02:15:46.484Z:INFO:taskMain.c:6230:Socket #1: Active current 14.3->15.9 due to current limit: ChargingProfile
2025-10-29T02:15:46.781Z:INFO:taskMain.c:6746:Socket #1: PWM DC 26.5% (15.9 A)
2025-10-29T02:16:23.500Z:INFO:taskMain.c:6798:Socket #1: reset HF switch count 1
2025-10-29T02:17:04.769Z:USER:taskMaster.c:6599:Socket #1: L1N=235.2V L2N=235.0V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T02:17:04.781Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T02:17:55.863Z:USER:taskMaster.c:6497:Temperature: 27.6 C
2025-10-29T02:23:36.425Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(24.0 23.0 20.0)A ALB:(24.0 23.0 20.0)A
2025-10-29T02:27:43.000Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T02:27:44.453Z:COM:ocpp_rpc.c:715:-> [2,"100","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"tim
2025-10-29T02:27:44.453Z:COM:ocpp_rpc.c:715:estamp":"2025-10-29T02:27:43Z","sampledValue":[{"value":"5526.141","context":"Sa
2025-10-29T02:27:44.453Z:COM:ocpp_rpc.c:715:mple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","
2025-10-29T02:27:44.453Z:COM:ocpp_rpc.c:715:unit":"kWh"}]}]}]
2025-10-29T02:27:44.515Z:COM:ocpp_rpc.c:1292:<- [3,"100",{}]
2025-10-29T02:32:04.671Z:USER:taskMaster.c:6599:Socket #1: L1N=234.5V L2N=234.4V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T02:32:04.683Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T02:32:56.269Z:USER:taskMaster.c:6497:Temperature: 26.0 C
2025-10-29T02:33:36.363Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-29T02:40:56.464Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_ON
2025-10-29T02:40:56.476Z:INFO:taskMaster.c:6553:Start logging meter values @30s.
2025-10-29T02:40:56.484Z:USER:taskMaster.c:6599:Socket #1: L1N=234.6V L2N=234.3V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T02:40:56.496Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T02:40:56.507Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_ON_BYPASS_ON
2025-10-29T02:40:56.519Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_C2
2025-10-29T02:40:56.527Z:INFO:taskMaster.c:4897:Socket #1: state led : CHARGING_POWER_ON
2025-10-29T02:40:56.535Z:COM:ocpp_rpc.c:715:-> [2,"101","StatusNotification",{"connectorId":1,"errorCode":"NoError","status"
2025-10-29T02:40:56.535Z:COM:ocpp_rpc.c:715::"Charging"}]
2025-10-29T02:40:56.558Z:COM:ocpp_rpc.c:1292:<- [3,"101",{}]
2025-10-29T02:40:56.574Z:INFO:taskMain.c:6730:Socket #1: CPhigh 6.3 V
2025-10-29T02:40:57.453Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-10-29T02:41:26.511Z:USER:taskMaster.c:6599:Socket #1: L1N=233.0V L2N=233.0V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T02:41:26.527Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-10-29T02:41:56.437Z:INFO:taskMain.c:6798:Socket #1: reset HF switch count 1
2025-10-29T02:41:56.511Z:USER:taskMaster.c:6599:Socket #1: L1N=233.0V L2N=233.1V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T02:41:56.523Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-10-29T02:42:26.507Z:USER:taskMaster.c:6599:Socket #1: L1N=232.9V L2N=232.9V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T02:42:26.519Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-10-29T02:42:43.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T02:42:44.968Z:COM:ocpp_rpc.c:715:-> [2,"102","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"tim
2025-10-29T02:42:44.968Z:COM:ocpp_rpc.c:715:estamp":"2025-10-29T02:42:43Z","sampledValue":[{"value":"5526.457","context":"Sa
2025-10-29T02:42:44.968Z:COM:ocpp_rpc.c:715:mple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","
2025-10-29T02:42:44.968Z:COM:ocpp_rpc.c:715:unit":"kWh"}]}]}]
2025-10-29T02:42:45.027Z:COM:ocpp_rpc.c:1292:<- [3,"102",{}]
2025-10-29T02:42:56.503Z:USER:taskMaster.c:6599:Socket #1: L1N=233.1V L2N=233.0V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T02:42:56.515Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-10-29T02:43:26.500Z:USER:taskMaster.c:6599:Socket #1: L1N=233.1V L2N=232.9V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T02:43:26.511Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-10-29T02:43:27.882Z:INFO:heap_trace.c:493:free: 61784/160768 (38.4%) min: 35456 (22.1%) alloc #: 214
2025-10-29T02:43:27.890Z:INFO:heap_trace.c:495:fragm: 33.5% 4K: 13.8% free blocks: # 21 largest: 41080
2025-10-29T02:43:36.300Z:INFO:active_lb.c:308:SMt:(16.0 17.0 20.0)A Free:(9.0 8.0 5.0)A ALB:(24.6 23.6 20.6)A
2025-10-29T02:43:56.500Z:USER:taskMaster.c:6599:Socket #1: L1N=232.8V L2N=232.7V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T02:43:56.511Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-10-29T02:44:26.496Z:USER:taskMaster.c:6599:Socket #1: L1N=233.0V L2N=232.9V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T02:44:26.507Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-10-29T02:44:56.492Z:USER:taskMaster.c:6599:Socket #1: L1N=233.0V L2N=232.9V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T02:44:56.503Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-10-29T02:45:26.488Z:USER:taskMaster.c:6599:Socket #1: L1N=233.2V L2N=233.0V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T02:45:26.500Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-10-29T02:45:56.484Z:USER:taskMaster.c:6599:Socket #1: L1N=233.1V L2N=233.0V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T02:45:56.496Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-10-29T02:45:56.507Z:INFO:taskMaster.c:6541:Stop logging meter values @30s.
2025-10-29T02:47:56.671Z:USER:taskMaster.c:6497:Temperature: 25.9 C
2025-10-29T02:53:36.238Z:INFO:active_lb.c:308:SMt:(16.0 17.0 20.0)A Free:(9.0 8.0 5.0)A ALB:(24.6 23.6 20.5)A
2025-10-29T02:57:43.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T02:57:44.484Z:COM:ocpp_rpc.c:715:-> [2,"103","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"tim
2025-10-29T02:57:44.484Z:COM:ocpp_rpc.c:715:estamp":"2025-10-29T02:57:44Z","sampledValue":[{"value":"5529.181","context":"Sa
2025-10-29T02:57:44.484Z:COM:ocpp_rpc.c:715:mple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","
2025-10-29T02:57:44.484Z:COM:ocpp_rpc.c:715:unit":"kWh"}]}]}]
2025-10-29T02:57:44.542Z:COM:ocpp_rpc.c:1292:<- [3,"103",{}]
2025-10-29T03:00:30.347Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-29T03:00:30.355Z:INFO:db_chargingprofi:26: socket 0
2025-10-29T03:00:30.363Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-29T03:00:30.371Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-29T03:00:30.378Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-29T03:00:30.386Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-29T03:00:30.398Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-29T03:00:30.406Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-29T03:00:30.417Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-29T03:00:30.425Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-29T03:00:30.433Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-29T03:00:30.441Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-29T03:00:30.449Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-29T03:00:30.457Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-29T03:00:30.464Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-29T03:00:30.472Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-29T03:00:30.484Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-29T03:00:30.492Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-29T03:00:30.500Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-29T03:00:30.507Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-29T03:00:30.515Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-29T03:00:30.523Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-29T03:00:30.531Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-29T03:00:56.390Z:USER:taskMaster.c:6599:Socket #1: L1N=232.7V L2N=232.5V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T03:00:56.402Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-29T03:02:57.027Z:USER:taskMaster.c:6497:Temperature: 28.1 C
2025-10-29T03:03:36.171Z:INFO:active_lb.c:308:SMt:(16.0 17.0 20.0)A Free:(9.0 8.0 5.0)A ALB:(24.5 23.6 20.6)A
2025-10-29T03:10:42.679Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_OFF
2025-10-29T03:10:42.687Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_OFF_BYPASS_OFF
2025-10-29T03:10:42.699Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B2
2025-10-29T03:10:42.707Z:INFO:taskMaster.c:4897:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-10-29T03:10:42.722Z:COM:ocpp_rpc.c:715:-> [2,"104","StatusNotification",{"connectorId":1,"errorCode":"NoError","status"
2025-10-29T03:10:42.722Z:COM:ocpp_rpc.c:715::"SuspendedEV"}]
2025-10-29T03:10:42.742Z:COM:ocpp_rpc.c:1292:<- [3,"104",{}]
2025-10-29T03:10:42.945Z:INFO:taskMain.c:6730:Socket #1: CPhigh 9.2 V
2025-10-29T03:10:43.726Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-10-29T03:10:46.183Z:INFO:taskMain.c:6230:Socket #1: Active current 15.9->14.3 due to current limit: Active-LoadBalancing
2025-10-29T03:10:46.753Z:INFO:taskMain.c:6746:Socket #1: PWM DC 23.8% (14.3 A)
2025-10-29T03:10:58.183Z:INFO:taskMain.c:6230:Socket #1: Active current 14.3->10.6 due to current limit: Active-LoadBalancing
2025-10-29T03:10:58.875Z:INFO:taskMain.c:6746:Socket #1: PWM DC 17.6% (10.6 A)
2025-10-29T03:11:10.183Z:INFO:taskMain.c:6230:Socket #1: Active current 10.6->14.4 due to current limit: Active-LoadBalancing
2025-10-29T03:11:10.992Z:INFO:taskMain.c:6746:Socket #1: PWM DC 23.9% (14.3 A)
2025-10-29T03:11:22.179Z:INFO:taskMain.c:6230:Socket #1: Active current 14.4->15.9 due to current limit: ChargingProfile
2025-10-29T03:11:23.109Z:INFO:taskMain.c:6746:Socket #1: PWM DC 26.5% (15.9 A)
2025-10-29T03:11:32.273Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_ON
2025-10-29T03:11:32.281Z:INFO:taskMaster.c:6553:Start logging meter values @30s.
2025-10-29T03:11:32.292Z:USER:taskMaster.c:6599:Socket #1: L1N=234.4V L2N=234.2V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T03:11:32.304Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T03:11:32.312Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_ON_BYPASS_ON
2025-10-29T03:11:32.324Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_C2
2025-10-29T03:11:32.332Z:INFO:taskMaster.c:4897:Socket #1: state led : CHARGING_POWER_ON
2025-10-29T03:11:32.343Z:COM:ocpp_rpc.c:715:-> [2,"105","StatusNotification",{"connectorId":1,"errorCode":"NoError","status"
2025-10-29T03:11:32.343Z:COM:ocpp_rpc.c:715::"Charging"}]
2025-10-29T03:11:32.367Z:COM:ocpp_rpc.c:1292:<- [3,"105",{}]
2025-10-29T03:11:33.210Z:INFO:taskMain.c:6730:Socket #1: CPhigh 6.3 V
2025-10-29T03:11:33.261Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-10-29T03:11:42.660Z:INFO:taskMain.c:6798:Socket #1: reset HF switch count 2
2025-10-29T03:12:02.320Z:USER:taskMaster.c:6599:Socket #1: L1N=232.7V L2N=232.6V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T03:12:02.332Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-10-29T03:12:32.316Z:USER:taskMaster.c:6599:Socket #1: L1N=232.6V L2N=232.7V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T03:12:32.328Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.8kW Idc=0.7mA
2025-10-29T03:12:43.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T03:12:43.988Z:COM:ocpp_rpc.c:715:-> [2,"106","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"tim
2025-10-29T03:12:43.988Z:COM:ocpp_rpc.c:715:estamp":"2025-10-29T03:12:43Z","sampledValue":[{"value":"5531.738","context":"Sa
2025-10-29T03:12:43.988Z:COM:ocpp_rpc.c:715:mple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","
2025-10-29T03:12:43.988Z:COM:ocpp_rpc.c:715:unit":"kWh"}]}]}]
2025-10-29T03:12:44.058Z:COM:ocpp_rpc.c:1292:<- [3,"106",{}]
2025-10-29T03:13:02.312Z:USER:taskMaster.c:6599:Socket #1: L1N=232.8V L2N=232.8V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T03:13:02.324Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-10-29T03:13:32.308Z:USER:taskMaster.c:6599:Socket #1: L1N=232.5V L2N=232.5V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T03:13:32.324Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-10-29T03:13:36.109Z:INFO:active_lb.c:308:SMt:(16.0 17.0 20.0)A Free:(9.0 8.0 5.0)A ALB:(24.6 23.7 20.6)A
2025-10-29T03:14:02.308Z:USER:taskMaster.c:6599:Socket #1: L1N=232.6V L2N=232.5V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T03:14:02.320Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-29T03:14:32.304Z:USER:taskMaster.c:6599:Socket #1: L1N=232.8V L2N=232.8V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T03:14:32.316Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-10-29T03:15:02.300Z:USER:taskMaster.c:6599:Socket #1: L1N=232.6V L2N=232.7V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T03:15:02.312Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-10-29T03:15:32.296Z:USER:taskMaster.c:6599:Socket #1: L1N=232.6V L2N=232.7V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T03:15:32.308Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-29T03:16:02.292Z:USER:taskMaster.c:6599:Socket #1: L1N=232.9V L2N=232.9V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T03:16:02.308Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-10-29T03:16:32.292Z:USER:taskMaster.c:6599:Socket #1: L1N=232.9V L2N=233.0V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T03:16:32.304Z:USER:taskMaster.c:6635:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-10-29T03:16:32.312Z:INFO:taskMaster.c:6541:Stop logging meter values @30s.
2025-10-29T03:17:57.433Z:USER:taskMaster.c:6497:Temperature: 29.4 C
2025-10-29T03:23:36.046Z:INFO:active_lb.c:308:SMt:(16.0 17.0 20.0)A Free:(9.0 8.0 5.0)A ALB:(24.4 23.6 20.5)A
2025-10-29T03:27:43.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T03:27:44.515Z:COM:ocpp_rpc.c:715:-> [2,"107","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"tim
2025-10-29T03:27:44.515Z:COM:ocpp_rpc.c:715:estamp":"2025-10-29T03:27:43Z","sampledValue":[{"value":"5534.453","context":"Sa
2025-10-29T03:27:44.515Z:COM:ocpp_rpc.c:715:mple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","
2025-10-29T03:27:44.515Z:COM:ocpp_rpc.c:715:unit":"kWh"}]}]}]
2025-10-29T03:27:44.562Z:COM:ocpp_rpc.c:1292:<- [3,"107",{}]
2025-10-29T03:31:32.195Z:USER:taskMaster.c:6599:Socket #1: L1N=232.8V L2N=232.8V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T03:31:32.207Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-10-29T03:32:57.835Z:USER:taskMaster.c:6497:Temperature: 30.5 C
2025-10-29T03:33:35.984Z:INFO:active_lb.c:308:SMt:(16.0 17.0 20.0)A Free:(9.0 8.0 5.0)A ALB:(24.5 23.6 20.6)A
2025-10-29T03:42:43.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T03:42:44.019Z:COM:ocpp_rpc.c:715:-> [2,"108","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"tim
2025-10-29T03:42:44.019Z:COM:ocpp_rpc.c:715:estamp":"2025-10-29T03:42:43Z","sampledValue":[{"value":"5537.169","context":"Sa
2025-10-29T03:42:44.019Z:COM:ocpp_rpc.c:715:mple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","
2025-10-29T03:42:44.019Z:COM:ocpp_rpc.c:715:unit":"kWh"}]}]}]
2025-10-29T03:42:44.078Z:COM:ocpp_rpc.c:1292:<- [3,"108",{}]
2025-10-29T03:43:35.917Z:INFO:active_lb.c:308:SMt:(16.0 17.0 20.0)A Free:(9.0 8.0 5.0)A ALB:(24.5 23.6 20.5)A
2025-10-29T03:46:32.101Z:USER:taskMaster.c:6599:Socket #1: L1N=232.8V L2N=232.8V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T03:46:32.113Z:USER:taskMaster.c:6635:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-10-29T03:47:58.191Z:USER:taskMaster.c:6497:Temperature: 31.1 C
2025-10-29T03:53:35.855Z:INFO:active_lb.c:308:SMt:(16.0 17.0 20.0)A Free:(9.0 8.0 5.0)A ALB:(24.5 23.6 20.6)A
2025-10-29T03:57:43.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T03:57:43.539Z:COM:ocpp_rpc.c:715:-> [2,"109","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"tim
2025-10-29T03:57:43.539Z:COM:ocpp_rpc.c:715:estamp":"2025-10-29T03:57:43Z","sampledValue":[{"value":"5539.881","context":"Sa
2025-10-29T03:57:43.539Z:COM:ocpp_rpc.c:715:mple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","
2025-10-29T03:57:43.539Z:COM:ocpp_rpc.c:715:unit":"kWh"}]}]}]
2025-10-29T03:57:43.593Z:COM:ocpp_rpc.c:1292:<- [3,"109",{}]
2025-10-29T03:59:02.519Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_OFF
2025-10-29T03:59:02.531Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_OFF_BYPASS_OFF
2025-10-29T03:59:02.539Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B2
2025-10-29T03:59:02.550Z:INFO:taskMaster.c:4897:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-10-29T03:59:02.558Z:COM:ocpp_rpc.c:715:-> [2,"110","StatusNotification",{"connectorId":1,"errorCode":"NoError","status"
2025-10-29T03:59:02.558Z:COM:ocpp_rpc.c:715::"SuspendedEV"}]
2025-10-29T03:59:02.582Z:COM:ocpp_rpc.c:1292:<- [3,"110",{}]
2025-10-29T03:59:03.179Z:INFO:taskMain.c:6730:Socket #1: CPhigh 9.3 V
2025-10-29T03:59:03.597Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-10-29T03:59:09.925Z:INFO:taskMain.c:6230:Socket #1: Active current 15.9->14.4 due to current limit: Active-LoadBalancing
2025-10-29T03:59:10.667Z:INFO:taskMain.c:6746:Socket #1: PWM DC 23.9% (14.3 A)
2025-10-29T03:59:21.925Z:INFO:taskMain.c:6230:Socket #1: Active current 14.4->10.6 due to current limit: Active-LoadBalancing
2025-10-29T03:59:22.785Z:INFO:taskMain.c:6746:Socket #1: PWM DC 17.6% (10.6 A)
2025-10-29T03:59:33.925Z:INFO:taskMain.c:6230:Socket #1: Active current 10.6->14.4 due to current limit: Active-LoadBalancing
2025-10-29T03:59:34.906Z:INFO:taskMain.c:6746:Socket #1: PWM DC 23.9% (14.3 A)
2025-10-29T03:59:45.921Z:INFO:taskMain.c:6230:Socket #1: Active current 14.4->15.9 due to current limit: ChargingProfile
2025-10-29T03:59:46.011Z:INFO:taskMain.c:6746:Socket #1: PWM DC 26.5% (15.9 A)
2025-10-29T04:00:02.531Z:INFO:taskMain.c:6798:Socket #1: reset HF switch count 1
2025-10-29T04:00:37.914Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-29T04:00:37.921Z:INFO:db_chargingprofi:26: socket 0
2025-10-29T04:00:37.929Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-29T04:00:37.941Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-29T04:00:37.945Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-29T04:00:37.957Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-29T04:00:37.968Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-29T04:00:37.976Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-29T04:00:37.984Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-29T04:00:37.992Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-29T04:00:38.000Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-29T04:00:38.007Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-29T04:00:38.015Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-29T04:00:38.023Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-29T04:00:38.031Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-29T04:00:38.042Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-29T04:00:38.050Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-29T04:00:38.058Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-29T04:00:38.070Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-29T04:00:38.078Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-29T04:00:38.085Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-29T04:00:38.093Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-29T04:00:38.101Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-29T04:01:32.003Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=233.9V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T04:01:32.015Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T04:02:58.597Z:USER:taskMaster.c:6497:Temperature: 31.2 C
2025-10-29T04:03:35.792Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-29T04:12:43.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T04:12:44.050Z:COM:ocpp_rpc.c:715:-> [2,"111","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"tim
2025-10-29T04:12:44.050Z:COM:ocpp_rpc.c:715:estamp":"2025-10-29T04:12:43Z","sampledValue":[{"value":"5540.121","context":"Sa
2025-10-29T04:12:44.050Z:COM:ocpp_rpc.c:715:mple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","
2025-10-29T04:12:44.050Z:COM:ocpp_rpc.c:715:unit":"kWh"}]}]}]
2025-10-29T04:12:44.105Z:COM:ocpp_rpc.c:1292:<- [3,"111",{}]
2025-10-29T04:13:35.730Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-29T04:16:31.910Z:USER:taskMaster.c:6599:Socket #1: L1N=232.9V L2N=232.9V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T04:16:31.921Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T04:17:58.953Z:USER:taskMaster.c:6497:Temperature: 29.0 C
2025-10-29T04:23:35.664Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-29T04:27:43.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T04:27:43.558Z:COM:ocpp_rpc.c:715:-> [2,"112","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"tim
2025-10-29T04:27:43.558Z:COM:ocpp_rpc.c:715:estamp":"2025-10-29T04:27:43Z","sampledValue":[{"value":"5540.121","context":"Sa
2025-10-29T04:27:43.558Z:COM:ocpp_rpc.c:715:mple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","
2025-10-29T04:27:43.558Z:COM:ocpp_rpc.c:715:unit":"kWh"}]}]}]
2025-10-29T04:27:43.625Z:COM:ocpp_rpc.c:1292:<- [3,"112",{}]
2025-10-29T04:31:31.816Z:USER:taskMaster.c:6599:Socket #1: L1N=233.3V L2N=233.3V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T04:31:31.828Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T04:32:59.355Z:USER:taskMaster.c:6497:Temperature: 27.4 C
2025-10-29T04:33:35.601Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-29T04:42:43.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T04:42:44.089Z:COM:ocpp_rpc.c:715:-> [2,"113","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"tim
2025-10-29T04:42:44.089Z:COM:ocpp_rpc.c:715:estamp":"2025-10-29T04:42:43Z","sampledValue":[{"value":"5540.121","context":"Sa
2025-10-29T04:42:44.089Z:COM:ocpp_rpc.c:715:mple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","
2025-10-29T04:42:44.089Z:COM:ocpp_rpc.c:715:unit":"kWh"}]}]}]
2025-10-29T04:42:44.148Z:COM:ocpp_rpc.c:1292:<- [3,"113",{}]
2025-10-29T04:43:18.800Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-29T04:43:19.070Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-29T04:43:27.121Z:INFO:heap_trace.c:493:free: 61784/160768 (38.4%) min: 35456 (22.1%) alloc #: 214
2025-10-29T04:43:27.132Z:INFO:heap_trace.c:495:fragm: 33.5% 4K: 13.8% free blocks: # 21 largest: 41080
2025-10-29T04:43:35.539Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-29T04:46:31.718Z:USER:taskMaster.c:6599:Socket #1: L1N=236.4V L2N=236.6V L3N=236.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T04:46:31.730Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T04:47:59.710Z:USER:taskMaster.c:6497:Temperature: 26.1 C
2025-10-29T04:53:35.476Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-29T04:57:43.000Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T04:57:43.601Z:COM:ocpp_rpc.c:715:-> [2,"114","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"tim
2025-10-29T04:57:43.601Z:COM:ocpp_rpc.c:715:estamp":"2025-10-29T04:57:43Z","sampledValue":[{"value":"5540.121","context":"Sa
2025-10-29T04:57:43.601Z:COM:ocpp_rpc.c:715:mple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","
2025-10-29T04:57:43.601Z:COM:ocpp_rpc.c:715:unit":"kWh"}]}]}]
2025-10-29T04:57:43.652Z:COM:ocpp_rpc.c:1292:<- [3,"114",{}]
2025-10-29T05:00:45.484Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-29T05:00:45.492Z:INFO:db_chargingprofi:26: socket 0
2025-10-29T05:00:45.500Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-29T05:00:45.507Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-29T05:00:45.515Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-29T05:00:45.527Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-29T05:00:45.535Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-29T05:00:45.542Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-29T05:00:45.554Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-29T05:00:45.562Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-29T05:00:45.570Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-29T05:00:45.578Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-29T05:00:45.585Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-29T05:00:45.593Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-29T05:00:45.601Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-29T05:00:45.609Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-29T05:00:45.621Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-29T05:00:45.628Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-29T05:00:45.636Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-29T05:00:45.644Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-29T05:00:45.652Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-29T05:00:45.660Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-29T05:00:45.667Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-29T05:01:31.625Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=235.0V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T05:01:31.636Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T05:03:00.167Z:USER:taskMaster.c:6497:Temperature: 25.5 C
2025-10-29T05:03:35.414Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T05:12:43.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T05:12:44.121Z:COM:ocpp_rpc.c:715:-> [2,"115","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"tim
2025-10-29T05:12:44.121Z:COM:ocpp_rpc.c:715:estamp":"2025-10-29T05:12:43Z","sampledValue":[{"value":"5540.121","context":"Sa
2025-10-29T05:12:44.121Z:COM:ocpp_rpc.c:715:mple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","
2025-10-29T05:12:44.121Z:COM:ocpp_rpc.c:715:unit":"kWh"}]}]}]
2025-10-29T05:12:44.175Z:COM:ocpp_rpc.c:1292:<- [3,"115",{}]
2025-10-29T05:13:35.347Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T05:16:31.531Z:USER:taskMaster.c:6599:Socket #1: L1N=236.2V L2N=236.0V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T05:16:31.542Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T05:18:00.519Z:USER:taskMaster.c:6497:Temperature: 24.9 C
2025-10-29T05:21:22.988Z:INFO:taskMain.c:6730:Socket #1: CPhigh 6.4 V
2025-10-29T05:21:23.000Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_ON
2025-10-29T05:21:23.007Z:INFO:taskMaster.c:6553:Start logging meter values @30s.
2025-10-29T05:21:23.019Z:USER:taskMaster.c:6599:Socket #1: L1N=234.9V L2N=234.9V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T05:21:23.031Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T05:21:23.039Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_ON_BYPASS_ON
2025-10-29T05:21:23.050Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_C2
2025-10-29T05:21:23.058Z:INFO:taskMaster.c:4897:Socket #1: state led : CHARGING_POWER_ON
2025-10-29T05:21:23.070Z:COM:ocpp_rpc.c:715:-> [2,"116","StatusNotification",{"connectorId":1,"errorCode":"NoError","status"
2025-10-29T05:21:23.070Z:COM:ocpp_rpc.c:715::"Charging"}]
2025-10-29T05:21:23.093Z:COM:ocpp_rpc.c:1292:<- [3,"116",{}]
2025-10-29T05:21:23.597Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_OFF
2025-10-29T05:21:23.609Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_OFF_BYPASS_OFF
2025-10-29T05:21:23.621Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B2
2025-10-29T05:21:23.628Z:INFO:taskMaster.c:4897:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-10-29T05:21:23.636Z:COM:ocpp_rpc.c:715:-> [2,"117","StatusNotification",{"connectorId":1,"errorCode":"NoError","status"
2025-10-29T05:21:23.636Z:COM:ocpp_rpc.c:715::"SuspendedEV"}]
2025-10-29T05:21:23.664Z:COM:ocpp_rpc.c:1292:<- [3,"117",{}]
2025-10-29T05:21:23.996Z:INFO:taskMain.c:6730:Socket #1: CPhigh 9.3 V
2025-10-29T05:21:24.644Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-10-29T05:21:53.046Z:USER:taskMaster.c:6599:Socket #1: L1N=235.2V L2N=235.2V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T05:21:53.058Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T05:22:22.980Z:INFO:taskMain.c:6798:Socket #1: reset HF switch count 2
2025-10-29T05:22:23.042Z:USER:taskMaster.c:6599:Socket #1: L1N=235.0V L2N=235.0V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T05:22:23.054Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T05:22:53.039Z:USER:taskMaster.c:6599:Socket #1: L1N=234.6V L2N=234.8V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T05:22:53.050Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T05:23:23.035Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=234.7V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T05:23:23.050Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T05:23:35.285Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T05:23:53.035Z:USER:taskMaster.c:6599:Socket #1: L1N=234.8V L2N=234.9V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T05:23:53.046Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T05:24:23.031Z:USER:taskMaster.c:6599:Socket #1: L1N=234.4V L2N=234.7V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T05:24:23.042Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T05:24:53.027Z:USER:taskMaster.c:6599:Socket #1: L1N=234.3V L2N=234.3V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T05:24:53.039Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T05:25:23.023Z:USER:taskMaster.c:6599:Socket #1: L1N=234.4V L2N=234.2V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T05:25:23.035Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T05:25:53.019Z:USER:taskMaster.c:6599:Socket #1: L1N=234.0V L2N=234.0V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T05:25:53.035Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.9mA
2025-10-29T05:26:23.019Z:USER:taskMaster.c:6599:Socket #1: L1N=234.2V L2N=234.1V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T05:26:23.031Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T05:26:23.039Z:INFO:taskMaster.c:6541:Stop logging meter values @30s.
2025-10-29T05:27:43.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T05:27:43.636Z:COM:ocpp_rpc.c:715:-> [2,"118","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"tim
2025-10-29T05:27:43.636Z:COM:ocpp_rpc.c:715:estamp":"2025-10-29T05:27:43Z","sampledValue":[{"value":"5540.121","context":"Sa
2025-10-29T05:27:43.636Z:COM:ocpp_rpc.c:715:mple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","
2025-10-29T05:27:43.636Z:COM:ocpp_rpc.c:715:unit":"kWh"}]}]}]
2025-10-29T05:27:43.691Z:COM:ocpp_rpc.c:1292:<- [3,"118",{}]
2025-10-29T05:33:00.875Z:USER:taskMaster.c:6497:Temperature: 24.4 C
2025-10-29T05:33:35.222Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.4 24.0 24.0)A
2025-10-29T05:41:22.921Z:USER:taskMaster.c:6599:Socket #1: L1N=235.0V L2N=235.3V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T05:41:22.933Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T05:42:43.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T05:42:44.160Z:COM:ocpp_rpc.c:715:-> [2,"119","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"tim
2025-10-29T05:42:44.160Z:COM:ocpp_rpc.c:715:estamp":"2025-10-29T05:42:43Z","sampledValue":[{"value":"5540.121","context":"Sa
2025-10-29T05:42:44.160Z:COM:ocpp_rpc.c:715:mple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","
2025-10-29T05:42:44.160Z:COM:ocpp_rpc.c:715:unit":"kWh"}]}]}]
2025-10-29T05:42:44.230Z:COM:ocpp_rpc.c:1292:<- [3,"119",{}]
2025-10-29T05:43:35.160Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.0 23.8 24.0)A
2025-10-29T05:48:01.281Z:USER:taskMaster.c:6497:Temperature: 24.6 C
2025-10-29T05:53:35.093Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.0 24.0 23.0)A
2025-10-29T05:56:22.828Z:USER:taskMaster.c:6599:Socket #1: L1N=233.5V L2N=233.8V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T05:56:22.839Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T05:57:43.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T05:57:43.687Z:COM:ocpp_rpc.c:715:-> [2,"120","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"tim
2025-10-29T05:57:43.687Z:COM:ocpp_rpc.c:715:estamp":"2025-10-29T05:57:43Z","sampledValue":[{"value":"5540.121","context":"Sa
2025-10-29T05:57:43.687Z:COM:ocpp_rpc.c:715:mple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","
2025-10-29T05:57:43.687Z:COM:ocpp_rpc.c:715:unit":"kWh"}]}]}]
2025-10-29T05:57:43.742Z:COM:ocpp_rpc.c:1292:<- [3,"120",{}]
2025-10-29T05:59:17.218Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-10-29T06:00:53.050Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-29T06:00:53.062Z:INFO:db_chargingprofi:26: socket 0
2025-10-29T06:00:53.070Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-29T06:00:53.078Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-29T06:00:53.085Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-29T06:00:53.093Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-29T06:00:53.105Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-29T06:00:53.113Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-29T06:00:53.121Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-29T06:00:53.128Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-29T06:00:53.136Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-29T06:00:53.144Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-29T06:00:53.152Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-29T06:00:53.160Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-29T06:00:53.167Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-29T06:00:53.179Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-29T06:00:53.187Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-29T06:00:53.195Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-29T06:00:53.207Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-29T06:00:53.214Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-29T06:00:53.222Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-29T06:00:53.230Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-29T06:00:53.238Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-29T06:03:01.636Z:USER:taskMaster.c:6497:Temperature: 24.5 C
2025-10-29T06:03:35.031Z:INFO:active_lb.c:308:SMt:(1.0 6.0 2.0)A Free:(24.0 19.0 23.0)A ALB:(24.0 19.0 23.0)A
2025-10-29T06:08:22.800Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_ON
2025-10-29T06:08:22.812Z:INFO:taskMaster.c:6553:Start logging meter values @30s.
2025-10-29T06:08:22.820Z:USER:taskMaster.c:6599:Socket #1: L1N=233.4V L2N=233.2V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T06:08:22.832Z:USER:taskMaster.c:6635:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-29T06:08:22.843Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_ON_BYPASS_ON
2025-10-29T06:08:22.851Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_C2
2025-10-29T06:08:22.863Z:INFO:taskMaster.c:4897:Socket #1: state led : CHARGING_POWER_ON
2025-10-29T06:08:22.871Z:COM:ocpp_rpc.c:715:-> [2,"121","StatusNotification",{"connectorId":1,"errorCode":"NoError","status"
2025-10-29T06:08:22.871Z:COM:ocpp_rpc.c:715::"Charging"}]
2025-10-29T06:08:22.894Z:COM:ocpp_rpc.c:1292:<- [3,"121",{}]
2025-10-29T06:08:23.257Z:INFO:taskMain.c:6730:Socket #1: CPhigh 6.3 V
2025-10-29T06:08:23.828Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-10-29T06:08:52.847Z:USER:taskMaster.c:6599:Socket #1: L1N=233.1V L2N=232.8V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T06:08:52.863Z:USER:taskMaster.c:6635:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-10-29T06:09:17.156Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-10-29T06:09:22.812Z:INFO:taskMain.c:6798:Socket #1: reset HF switch count 1
2025-10-29T06:09:22.843Z:USER:taskMaster.c:6599:Socket #1: L1N=232.5V L2N=232.4V L3N=232.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T06:09:22.855Z:USER:taskMaster.c:6635:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-10-29T06:09:52.843Z:USER:taskMaster.c:6599:Socket #1: L1N=232.5V L2N=232.2V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T06:09:52.855Z:USER:taskMaster.c:6635:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-10-29T06:10:22.839Z:USER:taskMaster.c:6599:Socket #1: L1N=232.6V L2N=232.6V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T06:10:22.851Z:USER:taskMaster.c:6635:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-10-29T06:10:52.835Z:USER:taskMaster.c:6599:Socket #1: L1N=232.5V L2N=232.4V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T06:10:52.847Z:USER:taskMaster.c:6635:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-10-29T06:11:22.832Z:USER:taskMaster.c:6599:Socket #1: L1N=232.4V L2N=232.0V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T06:11:22.843Z:USER:taskMaster.c:6635:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-10-29T06:11:52.828Z:USER:taskMaster.c:6599:Socket #1: L1N=232.6V L2N=232.4V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T06:11:52.839Z:USER:taskMaster.c:6635:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-10-29T06:12:22.828Z:USER:taskMaster.c:6599:Socket #1: L1N=232.6V L2N=232.3V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T06:12:22.839Z:USER:taskMaster.c:6635:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-10-29T06:12:43.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T06:12:43.195Z:COM:ocpp_rpc.c:715:-> [2,"122","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"tim
2025-10-29T06:12:43.195Z:COM:ocpp_rpc.c:715:estamp":"2025-10-29T06:12:43Z","sampledValue":[{"value":"5540.121","context":"Sa
2025-10-29T06:12:43.195Z:COM:ocpp_rpc.c:715:mple.Periodic","measurand":"Energy.Active.Import.Register","location":"Outlet","
2025-10-29T06:12:43.195Z:COM:ocpp_rpc.c:715:unit":"kWh"}]}]}]
2025-10-29T06:12:43.242Z:COM:ocpp_rpc.c:1292:<- [3,"122",{}]
2025-10-29T06:12:52.824Z:USER:taskMaster.c:6599:Socket #1: L1N=232.1V L2N=232.1V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T06:12:52.835Z:USER:taskMaster.c:6635:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-10-29T06:13:22.820Z:USER:taskMaster.c:6599:Socket #1: L1N=231.5V L2N=231.7V L3N=231.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T06:13:22.832Z:USER:taskMaster.c:6635:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-10-29T06:13:22.843Z:INFO:taskMaster.c:6541:Stop logging meter values @30s.
2025-10-29T06:13:34.968Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.5 24.5 23.5)A
2025-10-29T06:18:02.039Z:USER:taskMaster.c:6497:Temperature: 25.4 C
2025-10-29T06:19:17.191Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-10-29T06:22:40.988Z:WARNING:taskMain.c:4908:Socket #1: EV disconnected while charging (10.9V)
2025-10-29T06:22:41.011Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_WAIT_FOR_EV_RECONNECT
2025-10-29T06:22:41.023Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_A
2025-10-29T06:22:41.031Z:INFO:taskMaster.c:4897:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-10-29T06:22:41.226Z:INFO:taskMain.c:6730:Socket #1: CPhigh 12.3 V
2025-10-29T06:22:41.234Z:INFO:taskMain.c:6735:Socket #1: CPlow 12.3 V
2025-10-29T06:22:42.019Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_WAIT_FOR_EV_RECONNECT, CP: 12.3/12.3, tag: 04BB2
2025-10-29T06:22:42.019Z:INFO:taskMain.c:1424:9EAFD0F94
2025-10-29T06:22:51.007Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_TERMINATING
2025-10-29T06:22:51.019Z:ERROR:board_ng9xx.c:5565:Socket 1: input voltage while emergency relays off
2025-10-29T06:22:51.031Z:INFO:taskMain.c:943:Socket #1: charging session status set inactive
2025-10-29T06:22:51.039Z:USER:board_ng9xx.c:5059:Socket #1: unlock socket motor
2025-10-29T06:22:51.046Z:INFO:db_transaction.c:16:Added TransactionStop for socket 1 at 0x00000482 (ts: 2242-03-16 12:56:31)
2025-10-29T06:22:51.062Z:INFO:db_transaction.c:16:Updated TransactionStart for socket 1 at 0x00000000 (ts: 2025-10-28 18:27:42)
2025-10-29T06:22:51.074Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_OFF_BYPASS_OFF
2025-10-29T06:22:51.085Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_F
2025-10-29T06:22:51.093Z:INFO:taskMaster.c:4897:Socket #1: state led : ERROR_RELAYS
2025-10-29T06:22:51.101Z:INFO:taskMaster.c:4875:Socket #1: state main : ERROR_RELAYS
2025-10-29T06:22:51.113Z:INFO:taskMain.c:6730:Socket #1: CPhigh -11.7 V
2025-10-29T06:22:51.121Z:INFO:taskMain.c:6735:Socket #1: CPlow -11.7 V
2025-10-29T06:22:51.257Z:INFO:taskMain.c:6230:Socket #1: Active current 15.9->0.0 due to current limit: Cable
2025-10-29T06:22:51.460Z:ERROR:comFaults.c:365:Socket #1: Power switch error [102]
2025-10-29T06:22:51.476Z:COM:ocpp_rpc.c:715:-> [2,"123","StatusNotification",{"connectorId":1,"errorCode":"PowerSwitchFailur
2025-10-29T06:22:51.476Z:COM:ocpp_rpc.c:715:e","info":"Power switch error","status":"Faulted","vendorErrorCode":"102"}]
2025-10-29T06:22:51.535Z:COM:ocpp_rpc.c:1292:<- [3,"123",{}]
2025-10-29T06:22:52.066Z:INFO:taskMain.c:6740:Socket #1: PP 34464 Ohm (0 A)
2025-10-29T06:22:52.074Z:INFO:taskMain.c:1424:Socket #1: main state: ERROR_RELAYS, CP: -11.7/-11.7, tag: 04BB29EAFD0F94
2025-10-29T06:23:21.605Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_ON_BYPASS_OFF
2025-10-29T06:23:22.144Z:INFO:board_ng9xx.c:5628:Socket 1: emergency relays check OK
2025-10-29T06:23:22.156Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_OFF_BYPASS_OFF
2025-10-29T06:23:22.656Z:INFO:taskMaster.c:4875:Socket #1: state main : AVAILABLE
2025-10-29T06:23:22.714Z:USER:comFaults.c:386:Socket #1: Error 102 resolved
2025-10-29T06:23:22.722Z:COM:ocpp_rpc.c:715:-> [2,"124","StatusNotification",{"connectorId":1,"errorCode":"NoError","info":"
2025-10-29T06:23:22.722Z:COM:ocpp_rpc.c:715:Error 102 resolved","status":"Available","vendorErrorCode":"102"}]
2025-10-29T06:23:22.750Z:INFO:taskMain.c:6676:Socket #1: active tag cleared
2025-10-29T06:23:22.757Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_E
2025-10-29T06:23:22.769Z:INFO:taskMain.c:6730:Socket #1: CPhigh 0.0 V
2025-10-29T06:23:22.777Z:INFO:taskMain.c:6735:Socket #1: CPlow 0.0 V
2025-10-29T06:23:22.785Z:INFO:taskMaster.c:4897:Socket #1: state led : AVAILABLE
2025-10-29T06:23:22.792Z:COM:ocpp_rpc.c:1292:<- [3,"124",{}]
2025-10-29T06:23:23.785Z:INFO:taskMain.c:1426:Socket #1: main state: AVAILABLE, CP: 0.0/0.0, no tag
2025-10-29T06:23:34.906Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.2 23.8 23.9)A
2025-10-29T06:27:43.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T06:28:22.726Z:USER:taskMaster.c:6599:Socket #1: L1N=235.2V L2N=236.1V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T06:33:02.445Z:USER:taskMaster.c:6497:Temperature: 25.2 C
2025-10-29T06:33:34.843Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.5 24.0 24.0)A
2025-10-29T06:39:57.093Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-29T06:39:57.902Z:SECURITY:httpd_login.c:155:WebClient connected (account: admin)
2025-10-29T06:42:43.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T06:42:44.492Z:SECURITY:web_functionali:105:Webserver logout client 2
2025-10-29T06:42:44.507Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-29T06:42:44.531Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-29T06:43:22.628Z:USER:taskMaster.c:6599:Socket #1: L1N=233.2V L2N=232.9V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T06:43:26.359Z:INFO:heap_trace.c:493:free: 61736/160768 (38.4%) min: 35456 (22.1%) alloc #: 216
2025-10-29T06:43:26.371Z:INFO:heap_trace.c:495:fragm: 33.5% 4K: 13.7% free blocks: # 21 largest: 41080
2025-10-29T06:43:34.777Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T06:48:02.800Z:USER:taskMaster.c:6497:Temperature: 25.0 C
2025-10-29T06:53:34.714Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T06:57:43.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T06:58:22.535Z:USER:taskMaster.c:6599:Socket #1: L1N=235.1V L2N=234.8V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T07:03:03.207Z:USER:taskMaster.c:6497:Temperature: 24.6 C
2025-10-29T07:03:34.652Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T07:12:43.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T07:13:22.441Z:USER:taskMaster.c:6599:Socket #1: L1N=236.7V L2N=236.2V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T07:13:34.589Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.2 24.0 24.0)A
2025-10-29T07:18:03.562Z:USER:taskMaster.c:6497:Temperature: 24.5 C
2025-10-29T07:23:34.523Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.5 23.0 24.0)A
2025-10-29T07:27:43.000Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T07:28:22.343Z:USER:taskMaster.c:6599:Socket #1: L1N=236.7V L2N=235.8V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T07:33:03.964Z:USER:taskMaster.c:6497:Temperature: 24.6 C
2025-10-29T07:33:34.460Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.1 23.0 24.0)A
2025-10-29T07:42:43.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T07:43:22.250Z:USER:taskMaster.c:6599:Socket #1: L1N=235.6V L2N=235.1V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T07:43:34.398Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-29T07:48:04.371Z:USER:taskMaster.c:6497:Temperature: 24.9 C
2025-10-29T07:53:34.335Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.2 24.0 24.0)A
2025-10-29T07:57:43.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T07:58:22.156Z:USER:taskMaster.c:6599:Socket #1: L1N=231.4V L2N=231.1V L3N=231.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T08:03:04.726Z:USER:taskMaster.c:6497:Temperature: 25.0 C
2025-10-29T08:03:34.273Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-29T08:12:43.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T08:13:22.058Z:USER:taskMaster.c:6599:Socket #1: L1N=235.9V L2N=236.9V L3N=235.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T08:13:34.207Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(25.7 24.0 24.0)A
2025-10-29T08:18:05.179Z:USER:taskMaster.c:6497:Temperature: 25.2 C
2025-10-29T08:23:34.144Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-29T08:27:43.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T08:28:21.964Z:USER:taskMaster.c:6599:Socket #1: L1N=236.3V L2N=236.8V L3N=236.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T08:33:05.484Z:USER:taskMaster.c:6497:Temperature: 25.2 C
2025-10-29T08:33:34.082Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-29T08:42:43.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T08:43:17.003Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-29T08:43:17.269Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-29T08:43:21.871Z:USER:taskMaster.c:6599:Socket #1: L1N=236.4V L2N=236.4V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T08:43:25.601Z:INFO:heap_trace.c:493:free: 61736/160768 (38.4%) min: 35456 (22.1%) alloc #: 216
2025-10-29T08:43:25.609Z:INFO:heap_trace.c:495:fragm: 33.5% 4K: 13.7% free blocks: # 21 largest: 41080
2025-10-29T08:43:34.019Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-29T08:43:34.066Z:INFO:comFaults.c:482:Reset fault status
2025-10-29T08:48:05.890Z:USER:taskMaster.c:6497:Temperature: 25.2 C
2025-10-29T08:53:33.953Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(24.8 24.0 24.0)A
2025-10-29T08:57:43.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T08:58:21.773Z:USER:taskMaster.c:6599:Socket #1: L1N=236.2V L2N=236.9V L3N=236.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T09:03:06.292Z:USER:taskMaster.c:6497:Temperature: 25.4 C
2025-10-29T09:03:33.890Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.1 24.0 24.0)A
2025-10-29T09:12:43.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T09:13:21.679Z:USER:taskMaster.c:6599:Socket #1: L1N=236.2V L2N=237.4V L3N=236.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T09:13:33.828Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.7 24.0 24.0)A
2025-10-29T09:18:06.648Z:USER:taskMaster.c:6497:Temperature: 25.4 C
2025-10-29T09:23:33.765Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.3 24.0 24.0)A
2025-10-29T09:27:43.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T09:28:21.585Z:USER:taskMaster.c:6599:Socket #1: L1N=238.4V L2N=238.5V L3N=238.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T09:33:07.054Z:USER:taskMaster.c:6497:Temperature: 25.8 C
2025-10-29T09:33:33.703Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-29T09:42:43.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T09:43:21.488Z:USER:taskMaster.c:6599:Socket #1: L1N=234.6V L2N=234.5V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T09:43:33.636Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-29T09:48:07.410Z:USER:taskMaster.c:6497:Temperature: 26.0 C
2025-10-29T09:53:33.574Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.9 24.0 24.0)A
2025-10-29T09:57:43.000Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T09:58:21.394Z:USER:taskMaster.c:6599:Socket #1: L1N=235.7V L2N=236.9V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T10:03:07.863Z:USER:taskMaster.c:6497:Temperature: 26.1 C
2025-10-29T10:03:33.511Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(24.0 26.0 24.0)A ALB:(24.0 26.0 24.0)A
2025-10-29T10:12:02.714Z:USER:taskOCPP.c:503:Back office connection lost
2025-10-29T10:12:02.824Z:ERROR:tcp_rtos.c:372:Could not connect to 192.168.178.140:8080 (-1) : Connection reset by peer (104)
2025-10-29T10:12:02.835Z:ERROR:websockets.c:446:Open Socket failed
2025-10-29T10:12:43.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T10:13:02.722Z:INFO:comConnect.c:295:Connectivity state: DISCONNECT
2025-10-29T10:13:02.738Z:USER:comConnect.c:443:wired disconnect
2025-10-29T10:13:02.765Z:INFO:comConnect.c:663:connection attempt 2/3
2025-10-29T10:13:02.773Z:INFO:comConnect.c:295:Connectivity state: INITIALISING
2025-10-29T10:13:02.792Z:INFO:comConnect.c:295:Connectivity state: WIRED
2025-10-29T10:13:02.808Z:USER:comConnect.c:383:wired connect
2025-10-29T10:13:02.816Z:ERROR:tcp_rtos.c:372:Could not connect to 192.168.178.140:8080 (-1) : Connection reset by peer (104)
2025-10-29T10:13:02.832Z:ERROR:websockets.c:446:Open Socket failed
2025-10-29T10:13:21.300Z:USER:taskMaster.c:6599:Socket #1: L1N=235.2V L2N=236.1V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T10:13:33.449Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.3 24.0)A
2025-10-29T10:14:02.804Z:INFO:comConnect.c:295:Connectivity state: DISCONNECT
2025-10-29T10:14:02.832Z:INFO:comConnect.c:663:connection attempt 3/3
2025-10-29T10:14:02.839Z:INFO:comConnect.c:295:Connectivity state: INITIALISING
2025-10-29T10:14:02.859Z:INFO:comConnect.c:295:Connectivity state: WIRED
2025-10-29T10:14:02.878Z:USER:comConnect.c:383:wired connect
2025-10-29T10:14:02.886Z:ERROR:tcp_rtos.c:372:Could not connect to 192.168.178.140:8080 (-1) : Connection reset by peer (104)
2025-10-29T10:14:02.898Z:ERROR:websockets.c:446:Open Socket failed
2025-10-29T10:15:02.871Z:INFO:comConnect.c:295:Connectivity state: DISCONNECT
2025-10-29T10:15:02.898Z:INFO:comConnect.c:295:Connectivity state: INITIALISING
2025-10-29T10:15:02.914Z:INFO:comConnect.c:295:Connectivity state: STANDALONE
2025-10-29T10:15:02.945Z:INFO:comConnect.c:1106:Connecting wired to: ws://192.168.178.140:8080/steve/websocket/CentralSystemServ
2025-10-29T10:15:02.945Z:INFO:comConnect.c:1106:ice/VAN_01971, prio #1
2025-10-29T10:15:02.964Z:INFO:comConnect.c:663:connection attempt 1/3
2025-10-29T10:15:02.972Z:INFO:comConnect.c:295:Connectivity state: INITIALISING
2025-10-29T10:15:02.988Z:INFO:comConnect.c:295:Connectivity state: WIRED
2025-10-29T10:15:03.007Z:USER:comConnect.c:383:wired connect
2025-10-29T10:15:03.015Z:INFO:websockets.c:451:Connected to Socket 192.168.178.140:8080
2025-10-29T10:15:03.023Z:INFO:websockets.c:2363:WS timeout: 10000 ms
2025-10-29T10:15:03.316Z:INFO:websockets.c:824:WebSocket upgrade successful
2025-10-29T10:15:03.335Z:USER:taskOCPP.c:464:Back office connection available
2025-10-29T10:18:08.218Z:USER:taskMaster.c:6497:Temperature: 26.2 C
2025-10-29T10:23:33.386Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.1 24.0 24.0)A
2025-10-29T10:27:43.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T10:28:21.207Z:USER:taskMaster.c:6599:Socket #1: L1N=236.3V L2N=236.9V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T10:33:08.574Z:USER:taskMaster.c:6497:Temperature: 26.1 C
2025-10-29T10:33:33.320Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 25.7 24.0)A
2025-10-29T10:42:43.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T10:43:21.160Z:USER:taskMaster.c:6599:Socket #1: L1N=235.7V L2N=236.3V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T10:43:24.839Z:INFO:heap_trace.c:493:free: 61744/160768 (38.4%) min: 35456 (22.1%) alloc #: 216
2025-10-29T10:43:24.851Z:INFO:heap_trace.c:495:fragm: 33.5% 4K: 13.8% free blocks: # 23 largest: 41080
2025-10-29T10:43:33.257Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(24.0 26.0 24.0)A ALB:(24.2 26.0 24.0)A
2025-10-29T10:48:08.980Z:USER:taskMaster.c:6497:Temperature: 26.8 C
2025-10-29T10:53:33.195Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(24.0 26.0 24.0)A ALB:(24.0 26.0 24.0)A
2025-10-29T10:57:43.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T10:58:21.066Z:USER:taskMaster.c:6599:Socket #1: L1N=237.8V L2N=237.7V L3N=237.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T11:03:09.335Z:USER:taskMaster.c:6497:Temperature: 26.9 C
2025-10-29T11:03:33.132Z:INFO:active_lb.c:308:SMt:(-2.0 -3.0 1.0)A Free:(27.0 28.0 24.0)A ALB:(26.9 27.6 24.0)A
2025-10-29T11:12:43.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T11:13:20.968Z:USER:taskMaster.c:6599:Socket #1: L1N=235.9V L2N=236.6V L3N=236.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T11:13:33.070Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 26.0 23.9)A
2025-10-29T11:18:09.738Z:USER:taskMaster.c:6497:Temperature: 26.9 C
2025-10-29T11:23:33.003Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(25.3 26.0 24.0)A
2025-10-29T11:27:43.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T11:28:20.875Z:USER:taskMaster.c:6599:Socket #1: L1N=234.3V L2N=234.9V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T11:33:10.144Z:USER:taskMaster.c:6497:Temperature: 27.0 C
2025-10-29T11:33:32.941Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.2 24.0 24.0)A
2025-10-29T11:42:43.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T11:43:20.781Z:USER:taskMaster.c:6599:Socket #1: L1N=236.0V L2N=236.1V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T11:43:32.878Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 26.0 24.0)A
2025-10-29T11:48:10.500Z:USER:taskMaster.c:6497:Temperature: 27.1 C
2025-10-29T11:53:32.816Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(25.8 26.0 24.0)A
2025-10-29T11:57:43.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T11:58:20.683Z:USER:taskMaster.c:6599:Socket #1: L1N=236.6V L2N=236.3V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T12:03:10.906Z:USER:taskMaster.c:6497:Temperature: 27.2 C
2025-10-29T12:03:32.753Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-29T12:12:43.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T12:13:20.589Z:USER:taskMaster.c:6599:Socket #1: L1N=234.0V L2N=234.1V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T12:13:32.687Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-29T12:18:11.308Z:USER:taskMaster.c:6497:Temperature: 27.2 C
2025-10-29T12:23:32.625Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.0 24.0 23.2)A
2025-10-29T12:27:43.000Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T12:28:20.496Z:USER:taskMaster.c:6599:Socket #1: L1N=233.6V L2N=233.9V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T12:33:11.664Z:USER:taskMaster.c:6497:Temperature: 27.2 C
2025-10-29T12:33:32.562Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.3 24.0 24.0)A
2025-10-29T12:42:43.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T12:43:16.199Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-29T12:43:16.468Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-29T12:43:20.398Z:USER:taskMaster.c:6599:Socket #1: L1N=236.0V L2N=235.8V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T12:43:24.082Z:INFO:heap_trace.c:493:free: 61688/160768 (38.4%) min: 35456 (22.1%) alloc #: 217
2025-10-29T12:43:24.089Z:INFO:heap_trace.c:495:fragm: 33.4% 4K: 13.7% free blocks: # 23 largest: 41080
2025-10-29T12:43:32.500Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-29T12:48:12.070Z:USER:taskMaster.c:6497:Temperature: 27.5 C
2025-10-29T12:53:32.437Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-29T12:57:43.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T12:58:20.304Z:USER:taskMaster.c:6599:Socket #1: L1N=237.0V L2N=235.8V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T13:03:12.425Z:USER:taskMaster.c:6497:Temperature: 27.2 C
2025-10-29T13:03:32.371Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(25.8 24.0 24.0)A
2025-10-29T13:12:43.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T13:13:20.210Z:USER:taskMaster.c:6599:Socket #1: L1N=236.6V L2N=237.0V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T13:13:32.308Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.7 24.0 24.0)A
2025-10-29T13:18:12.828Z:USER:taskMaster.c:6497:Temperature: 27.1 C
2025-10-29T13:23:32.246Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-29T13:27:43.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T13:28:20.117Z:USER:taskMaster.c:6599:Socket #1: L1N=235.7V L2N=236.0V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T13:33:13.183Z:USER:taskMaster.c:6497:Temperature: 27.1 C
2025-10-29T13:33:32.183Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(26.0 24.0 24.0)A
2025-10-29T13:42:43.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T13:43:20.019Z:USER:taskMaster.c:6599:Socket #1: L1N=236.6V L2N=236.5V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T13:43:32.121Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T13:48:13.589Z:USER:taskMaster.c:6497:Temperature: 27.4 C
2025-10-29T13:53:32.054Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-29T13:57:43.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T13:58:19.925Z:USER:taskMaster.c:6599:Socket #1: L1N=235.8V L2N=236.3V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T14:03:13.996Z:USER:taskMaster.c:6497:Temperature: 27.6 C
2025-10-29T14:03:31.992Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-29T14:12:43.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T14:13:19.832Z:USER:taskMaster.c:6599:Socket #1: L1N=232.7V L2N=233.1V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T14:13:31.929Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-29T14:18:14.351Z:USER:taskMaster.c:6497:Temperature: 27.6 C
2025-10-29T14:23:31.867Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T14:27:43.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T14:28:19.734Z:USER:taskMaster.c:6599:Socket #1: L1N=235.8V L2N=236.6V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T14:33:14.707Z:USER:taskMaster.c:6497:Temperature: 27.4 C
2025-10-29T14:33:31.804Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T14:37:46.515Z:COM:ocpp_rpc.c:715:-> [2,"125","Heartbeat",{}]
2025-10-29T14:37:48.046Z:COM:ocpp_rpc.c:1292:<- [3,"125",{"currentTime":"2025-10-29T14:37:51.766Z"}]
2025-10-29T14:42:43.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T14:43:22.582Z:USER:taskMaster.c:6599:Socket #1: L1N=235.6V L2N=236.0V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T14:43:26.261Z:INFO:heap_trace.c:493:free: 61744/160768 (38.4%) min: 35456 (22.1%) alloc #: 216
2025-10-29T14:43:26.273Z:INFO:heap_trace.c:495:fragm: 33.5% 4K: 13.8% free blocks: # 23 largest: 41080
2025-10-29T14:43:34.679Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(24.8 24.0 24.0)A
2025-10-29T14:48:18.050Z:USER:taskMaster.c:6497:Temperature: 27.1 C
2025-10-29T14:53:34.617Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.1 24.0 24.0)A
2025-10-29T14:57:43.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T14:58:22.484Z:USER:taskMaster.c:6599:Socket #1: L1N=234.8V L2N=235.8V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T15:03:18.453Z:USER:taskMaster.c:6497:Temperature: 27.1 C
2025-10-29T15:03:34.554Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(25.0 24.0 24.0)A
2025-10-29T15:12:43.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T15:13:22.390Z:USER:taskMaster.c:6599:Socket #1: L1N=235.2V L2N=235.1V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T15:13:34.488Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T15:18:18.808Z:USER:taskMaster.c:6497:Temperature: 27.0 C
2025-10-29T15:20:36.058Z:COM:ocpp_rpc.c:1292:<- [2,"17960de7-5d41-4ed7-9c3e-dc649c56c350","GetConfiguration",{"key":["StopTra
2025-10-29T15:20:36.058Z:COM:ocpp_rpc.c:1292:nsactionOnEVSideDisconnect"]}]
2025-10-29T15:20:36.082Z:COM:ocpp_rpc.c:715:-> [3,"17960de7-5d41-4ed7-9c3e-dc649c56c350",{"configurationKey":[{"key":"StopTr
2025-10-29T15:20:36.082Z:COM:ocpp_rpc.c:715:ansactionOnEVSideDisconnect","readonly":false,"value":"True"}]}]
2025-10-29T15:21:44.339Z:COM:ocpp_rpc.c:1292:<- [2,"76f6d88b-7fb1-4f30-9308-354cb4ab9a7d","GetConfiguration",{"key":["UnlockC
2025-10-29T15:21:44.339Z:COM:ocpp_rpc.c:1292:onnectorOnEVSideDisconnect"]}]
2025-10-29T15:21:44.363Z:COM:ocpp_rpc.c:715:-> [3,"76f6d88b-7fb1-4f30-9308-354cb4ab9a7d",{"configurationKey":[{"key":"Unlock
2025-10-29T15:21:44.363Z:COM:ocpp_rpc.c:715:ConnectorOnEVSideDisconnect","readonly":false,"value":"True"}]}]
2025-10-29T15:22:12.867Z:COM:ocpp_rpc.c:1292:<- [2,"f9a246d7-ef66-483f-a53d-78c2875eb664","GetConfiguration",{"key":["StopTxn
2025-10-29T15:22:12.867Z:COM:ocpp_rpc.c:1292:AlignedData"]}]
2025-10-29T15:22:12.886Z:COM:ocpp_rpc.c:715:-> [3,"f9a246d7-ef66-483f-a53d-78c2875eb664",{"configurationKey":[{"key":"StopTx
2025-10-29T15:22:12.886Z:COM:ocpp_rpc.c:715:nAlignedData","readonly":false,"value":"Energy.Active.Import.Register"}]}]
2025-10-29T15:23:34.425Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(23.9 24.0 23.0)A
2025-10-29T15:23:37.300Z:COM:ocpp_rpc.c:1292:<- [2,"c3188c06-062c-41a4-9e9c-fc07c71d1fbb","ChangeAvailability",{"connectorId"
2025-10-29T15:23:37.300Z:COM:ocpp_rpc.c:1292::0,"type":"Inoperative"}]
2025-10-29T15:23:37.519Z:COM:ocpp_rpc.c:715:-> [3,"c3188c06-062c-41a4-9e9c-fc07c71d1fbb",{"status":"Accepted"}]
2025-10-29T15:23:37.531Z:COM:ocpp_rpc.c:715:-> [2,"277","StatusNotification",{"connectorId":0,"errorCode":"NoError","status"
2025-10-29T15:23:37.531Z:COM:ocpp_rpc.c:715::"Unavailable"}]
2025-10-29T15:23:38.031Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-29T15:23:38.062Z:INFO:taskCANopen.c:1775:Updated object 0x205f, 8 bytes
2025-10-29T15:23:39.664Z:COM:ocpp_rpc.c:1292:<- [3,"277",{}]
2025-10-29T15:24:46.390Z:COM:ocpp_rpc.c:1292:<- [2,"88a3f344-9860-49be-9065-617733d44e64","GetConfiguration",{"key":["StopTra
2025-10-29T15:24:46.390Z:COM:ocpp_rpc.c:1292:nsactionOnInvalidId"]}]
2025-10-29T15:24:46.410Z:COM:ocpp_rpc.c:715:-> [3,"88a3f344-9860-49be-9065-617733d44e64",{"configurationKey":[{"key":"StopTr
2025-10-29T15:24:46.410Z:COM:ocpp_rpc.c:715:ansactionOnInvalidId","readonly":false,"value":"False"}]}]
2025-10-29T15:27:13.101Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-29T15:27:13.812Z:SECURITY:httpd_login.c:155:WebClient connected (account: admin)
2025-10-29T15:27:13.886Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-10-29T15:27:43.000Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T15:28:22.296Z:USER:taskMaster.c:6599:Socket #1: L1N=233.7V L2N=234.7V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T15:31:14.386Z:SECURITY:web_functionalit:65:Changed '2136_00' from 10 => 60
2025-10-29T15:31:14.523Z:SECURITY:web_functionalit:68:Changed '2187_00' from 1761210656363 => 1761751876806
2025-10-29T15:31:15.261Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-29T15:31:15.468Z:INFO:taskCANopen.c:1775:Updated object 0x2136, 2 bytes
2025-10-29T15:31:15.535Z:INFO:taskCANopen.c:1775:Updated object 0x2187, 8 bytes
2025-10-29T15:33:19.164Z:USER:taskMaster.c:6497:Temperature: 27.0 C
2025-10-29T15:33:34.363Z:INFO:active_lb.c:308:SMt:(2.0 1.0 2.0)A Free:(23.0 24.0 23.0)A ALB:(23.4 24.0 23.0)A
2025-10-29T15:37:05.566Z:SECURITY:web_functionali:105:Webserver logout client 2
2025-10-29T15:37:05.585Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-29T15:37:05.660Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-29T15:42:43.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T15:43:22.203Z:USER:taskMaster.c:6599:Socket #1: L1N=233.1V L2N=233.4V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T15:43:34.300Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.4 24.0)A
2025-10-29T15:48:19.570Z:USER:taskMaster.c:6497:Temperature: 26.9 C
2025-10-29T15:53:34.238Z:INFO:active_lb.c:308:SMt:(1.0 5.0 1.0)A Free:(24.0 20.0 24.0)A ALB:(24.0 20.0 24.0)A
2025-10-29T15:57:43.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T15:58:22.105Z:USER:taskMaster.c:6599:Socket #1: L1N=229.9V L2N=231.3V L3N=230.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T16:03:19.925Z:USER:taskMaster.c:6497:Temperature: 26.9 C
2025-10-29T16:03:34.171Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-29T16:12:43.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T16:13:22.011Z:USER:taskMaster.c:6599:Socket #1: L1N=233.0V L2N=233.3V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T16:13:34.109Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(23.8 22.0 24.0)A
2025-10-29T16:18:20.332Z:USER:taskMaster.c:6497:Temperature: 26.8 C
2025-10-29T16:23:34.046Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-29T16:26:12.191Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-10-29T16:27:43.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T16:28:21.917Z:USER:taskMaster.c:6599:Socket #1: L1N=232.4V L2N=233.5V L3N=231.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T16:33:20.734Z:USER:taskMaster.c:6497:Temperature: 26.5 C
2025-10-29T16:33:33.984Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-29T16:36:12.128Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-10-29T16:42:43.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T16:43:17.332Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-29T16:43:17.601Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-29T16:43:21.820Z:USER:taskMaster.c:6599:Socket #1: L1N=232.9V L2N=233.8V L3N=231.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T16:43:25.503Z:INFO:heap_trace.c:493:free: 61744/160768 (38.4%) min: 35456 (22.1%) alloc #: 216
2025-10-29T16:43:25.511Z:INFO:heap_trace.c:495:fragm: 33.5% 4K: 13.8% free blocks: # 23 largest: 41080
2025-10-29T16:43:33.921Z:INFO:active_lb.c:308:SMt:(3.0 3.0 1.0)A Free:(22.0 22.0 24.0)A ALB:(23.2 22.0 24.0)A
2025-10-29T16:46:12.164Z:INFO:taskLeds.c:338:Brightness set to 8%
2025-10-29T16:48:21.089Z:USER:taskMaster.c:6497:Temperature: 26.1 C
2025-10-29T16:53:33.855Z:INFO:active_lb.c:308:SMt:(7.0 2.0 2.0)A Free:(18.0 23.0 23.0)A ALB:(20.2 23.0 23.4)A
2025-10-29T16:57:43.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T16:58:21.726Z:USER:taskMaster.c:6599:Socket #1: L1N=233.2V L2N=233.2V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T17:03:21.496Z:USER:taskMaster.c:6497:Temperature: 26.1 C
2025-10-29T17:03:33.792Z:INFO:active_lb.c:308:SMt:(11.0 2.0 2.0)A Free:(14.0 23.0 23.0)A ALB:(17.3 23.0 23.0)A
2025-10-29T17:12:43.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T17:13:21.683Z:USER:taskMaster.c:6599:Socket #1: L1N=231.7V L2N=231.2V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T17:13:33.730Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(23.0 22.0 24.0)A ALB:(23.0 22.3 24.0)A
2025-10-29T17:18:21.851Z:USER:taskMaster.c:6497:Temperature: 26.1 C
2025-10-29T17:23:33.667Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 24.0 24.0)A
2025-10-29T17:27:43.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T17:28:21.585Z:USER:taskMaster.c:6599:Socket #1: L1N=234.5V L2N=232.5V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T17:33:22.257Z:USER:taskMaster.c:6497:Temperature: 25.8 C
2025-10-29T17:33:33.605Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(24.0 23.0 23.0)A ALB:(24.0 23.0 23.0)A
2025-10-29T17:42:43.046Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T17:43:21.492Z:USER:taskMaster.c:6599:Socket #1: L1N=233.8V L2N=233.7V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T17:43:33.542Z:INFO:active_lb.c:308:SMt:(2.0 2.0 2.0)A Free:(23.0 23.0 23.0)A ALB:(23.0 23.0 23.0)A
2025-10-29T17:48:22.660Z:USER:taskMaster.c:6497:Temperature: 26.1 C
2025-10-29T17:53:33.476Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(24.0 23.0 23.0)A ALB:(24.0 23.0 23.0)A
2025-10-29T17:57:43.000Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T17:58:21.398Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=234.2V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T18:03:22.964Z:USER:taskMaster.c:6497:Temperature: 26.0 C
2025-10-29T18:03:33.414Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(24.0 23.0 23.0)A ALB:(24.0 23.0 23.0)A
2025-10-29T18:12:43.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T18:13:21.300Z:USER:taskMaster.c:6599:Socket #1: L1N=232.0V L2N=232.7V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T18:13:33.351Z:INFO:active_lb.c:308:SMt:(2.0 2.0 2.0)A Free:(23.0 23.0 23.0)A ALB:(21.7 23.0 23.0)A
2025-10-29T18:18:23.371Z:USER:taskMaster.c:6497:Temperature: 26.1 C
2025-10-29T18:23:33.289Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(24.0 22.0 23.0)A ALB:(24.0 22.0 23.0)A
2025-10-29T18:27:43.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T18:27:44.109Z:INFO:taskMaster.c:6294:Socket #1: no schedule
2025-10-29T18:27:44.117Z:USER:taskMaster.c:6318:Socket #1: external current limit 16.0 A
2025-10-29T18:28:21.207Z:USER:taskMaster.c:6599:Socket #1: L1N=232.8V L2N=232.8V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T18:33:23.675Z:USER:taskMaster.c:6497:Temperature: 26.2 C
2025-10-29T18:33:33.226Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.2 24.0)A
2025-10-29T18:42:43.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T18:43:21.113Z:USER:taskMaster.c:6599:Socket #1: L1N=234.8V L2N=234.8V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T18:43:24.742Z:INFO:heap_trace.c:493:free: 61584/160768 (38.3%) min: 35456 (22.1%) alloc #: 218
2025-10-29T18:43:24.753Z:INFO:heap_trace.c:495:fragm: 33.3% 4K: 13.5% free blocks: # 21 largest: 41080
2025-10-29T18:43:33.160Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.4 24.0 24.0)A
2025-10-29T18:48:23.730Z:USER:taskMaster.c:6497:Temperature: 26.0 C
2025-10-29T18:53:33.097Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T18:57:43.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T18:58:21.019Z:USER:taskMaster.c:6599:Socket #1: L1N=235.2V L2N=234.8V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T19:03:24.535Z:USER:taskMaster.c:6497:Temperature: 26.1 C
2025-10-29T19:03:33.035Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.8 24.0 24.0)A
2025-10-29T19:12:43.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T19:13:20.921Z:USER:taskMaster.c:6599:Socket #1: L1N=232.9V L2N=232.9V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T19:13:32.972Z:INFO:active_lb.c:308:SMt:(3.0 1.0 1.0)A Free:(22.0 24.0 24.0)A ALB:(22.0 24.0 24.0)A
2025-10-29T19:18:24.941Z:USER:taskMaster.c:6497:Temperature: 26.1 C
2025-10-29T19:23:32.910Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T19:27:43.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T19:28:20.828Z:USER:taskMaster.c:6599:Socket #1: L1N=233.4V L2N=233.7V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T19:33:25.347Z:USER:taskMaster.c:6497:Temperature: 25.9 C
2025-10-29T19:33:32.843Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T19:42:43.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T19:43:20.734Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=234.8V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T19:43:32.781Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 24.0 24.0)A
2025-10-29T19:48:25.800Z:USER:taskMaster.c:6497:Temperature: 25.9 C
2025-10-29T19:53:32.718Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T19:57:43.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T19:58:20.636Z:USER:taskMaster.c:6599:Socket #1: L1N=235.7V L2N=235.5V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T20:03:26.304Z:USER:taskMaster.c:6497:Temperature: 25.6 C
2025-10-29T20:03:32.656Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.9 24.0 24.0)A
2025-10-29T20:12:43.046Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T20:13:20.542Z:USER:taskMaster.c:6599:Socket #1: L1N=231.8V L2N=231.5V L3N=230.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T20:13:32.593Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T20:18:26.710Z:USER:taskMaster.c:6497:Temperature: 25.6 C
2025-10-29T20:23:32.527Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 24.0 24.0)A
2025-10-29T20:27:43.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T20:28:20.449Z:USER:taskMaster.c:6599:Socket #1: L1N=235.5V L2N=235.4V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T20:33:27.117Z:USER:taskMaster.c:6497:Temperature: 25.4 C
2025-10-29T20:33:32.464Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.2 24.0 24.0)A
2025-10-29T20:42:43.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T20:43:15.566Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-29T20:43:15.832Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-29T20:43:20.351Z:USER:taskMaster.c:6599:Socket #1: L1N=233.4V L2N=233.3V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T20:43:23.984Z:INFO:heap_trace.c:493:free: 61744/160768 (38.4%) min: 35456 (22.1%) alloc #: 216
2025-10-29T20:43:23.996Z:INFO:heap_trace.c:495:fragm: 33.5% 4K: 13.8% free blocks: # 23 largest: 41080
2025-10-29T20:43:32.402Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T20:43:32.453Z:INFO:comFaults.c:482:Reset fault status
2025-10-29T20:48:27.621Z:USER:taskMaster.c:6497:Temperature: 25.4 C
2025-10-29T20:53:32.339Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T20:57:43.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T20:58:20.257Z:USER:taskMaster.c:6599:Socket #1: L1N=235.6V L2N=235.7V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T21:03:28.027Z:USER:taskMaster.c:6497:Temperature: 25.2 C
2025-10-29T21:03:32.277Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 24.0 24.0)A
2025-10-29T21:12:43.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T21:13:20.164Z:USER:taskMaster.c:6599:Socket #1: L1N=235.6V L2N=236.1V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T21:13:32.210Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.3 24.0 24.0)A
2025-10-29T21:18:28.429Z:USER:taskMaster.c:6497:Temperature: 25.2 C
2025-10-29T21:23:32.148Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.4 24.0 24.0)A
2025-10-29T21:27:43.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T21:28:20.070Z:USER:taskMaster.c:6599:Socket #1: L1N=233.8V L2N=233.8V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T21:33:29.285Z:USER:taskMaster.c:6497:Temperature: 25.2 C
2025-10-29T21:33:32.085Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(23.6 23.0 24.0)A
2025-10-29T21:42:43.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T21:43:19.972Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=234.9V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T21:43:32.023Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(23.9 23.0 24.0)A
2025-10-29T21:48:29.292Z:USER:taskMaster.c:6497:Temperature: 25.2 C
2025-10-29T21:53:31.957Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-29T21:57:43.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T21:58:19.878Z:USER:taskMaster.c:6599:Socket #1: L1N=236.4V L2N=236.9V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T22:03:29.695Z:USER:taskMaster.c:6497:Temperature: 25.2 C
2025-10-29T22:03:31.894Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-29T22:12:43.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T22:13:19.785Z:USER:taskMaster.c:6599:Socket #1: L1N=233.8V L2N=234.0V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T22:13:31.832Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-29T22:18:30.101Z:USER:taskMaster.c:6497:Temperature: 25.2 C
2025-10-29T22:23:31.769Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-29T22:27:43.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T22:28:19.687Z:USER:taskMaster.c:6599:Socket #1: L1N=234.5V L2N=234.4V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T22:33:30.554Z:USER:taskMaster.c:6497:Temperature: 25.1 C
2025-10-29T22:33:31.707Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-29T22:42:43.046Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T22:43:19.593Z:USER:taskMaster.c:6599:Socket #1: L1N=235.6V L2N=234.8V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T22:43:23.222Z:INFO:heap_trace.c:493:free: 61744/160768 (38.4%) min: 35456 (22.1%) alloc #: 216
2025-10-29T22:43:23.234Z:INFO:heap_trace.c:495:fragm: 33.5% 4K: 13.8% free blocks: # 23 largest: 41080
2025-10-29T22:43:31.640Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-29T22:48:30.960Z:USER:taskMaster.c:6497:Temperature: 25.2 C
2025-10-29T22:53:31.578Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(23.0 23.0 24.0)A ALB:(23.0 23.0 24.0)A
2025-10-29T22:57:43.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T22:58:19.500Z:USER:taskMaster.c:6599:Socket #1: L1N=232.8V L2N=232.4V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T23:03:31.515Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-29T23:03:31.664Z:USER:taskMaster.c:6497:Temperature: 25.1 C
2025-10-29T23:12:43.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T23:13:19.402Z:USER:taskMaster.c:6599:Socket #1: L1N=232.4V L2N=232.4V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T23:13:31.453Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-29T23:18:31.820Z:USER:taskMaster.c:6497:Temperature: 25.2 C
2025-10-29T23:23:31.390Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-29T23:27:43.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T23:28:19.308Z:USER:taskMaster.c:6599:Socket #1: L1N=233.6V L2N=233.7V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T23:33:31.324Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-29T23:33:32.476Z:USER:taskMaster.c:6497:Temperature: 25.0 C
2025-10-29T23:42:43.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T23:43:19.214Z:USER:taskMaster.c:6599:Socket #1: L1N=233.3V L2N=233.5V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-29T23:43:31.261Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-29T23:48:32.832Z:USER:taskMaster.c:6497:Temperature: 25.1 C
2025-10-29T23:53:31.199Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-29T23:57:43.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-29T23:58:19.117Z:USER:taskMaster.c:6599:Socket #1: L1N=234.6V L2N=234.8V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T00:03:31.136Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T00:03:33.238Z:USER:taskMaster.c:6497:Temperature: 25.1 C
2025-10-30T00:12:43.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T00:13:19.023Z:USER:taskMaster.c:6599:Socket #1: L1N=233.8V L2N=233.9V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T00:13:31.074Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T00:18:33.539Z:USER:taskMaster.c:6497:Temperature: 25.0 C
2025-10-30T00:23:31.007Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T00:27:43.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T00:28:18.929Z:USER:taskMaster.c:6599:Socket #1: L1N=234.4V L2N=234.9V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T00:33:30.945Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T00:33:34.046Z:USER:taskMaster.c:6497:Temperature: 24.9 C
2025-10-30T00:42:43.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T00:43:14.867Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-30T00:43:15.136Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-30T00:43:18.832Z:USER:taskMaster.c:6599:Socket #1: L1N=232.8V L2N=233.3V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T00:43:22.464Z:INFO:heap_trace.c:493:free: 61744/160768 (38.4%) min: 35456 (22.1%) alloc #: 216
2025-10-30T00:43:22.476Z:INFO:heap_trace.c:495:fragm: 33.5% 4K: 13.8% free blocks: # 23 largest: 41080
2025-10-30T00:43:30.882Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 24.0 24.0)A
2025-10-30T00:48:34.449Z:USER:taskMaster.c:6497:Temperature: 24.8 C
2025-10-30T00:53:30.820Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.2 24.0 24.0)A
2025-10-30T00:57:43.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T00:58:18.738Z:USER:taskMaster.c:6599:Socket #1: L1N=235.8V L2N=236.6V L3N=236.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T01:03:30.753Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T01:03:34.855Z:USER:taskMaster.c:6497:Temperature: 24.5 C
2025-10-30T01:12:43.046Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T01:13:18.644Z:USER:taskMaster.c:6599:Socket #1: L1N=235.5V L2N=235.8V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T01:13:30.691Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T01:18:35.261Z:USER:taskMaster.c:6497:Temperature: 24.0 C
2025-10-30T01:23:30.628Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T01:27:43.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T01:28:18.546Z:USER:taskMaster.c:6599:Socket #1: L1N=233.8V L2N=234.4V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T01:33:30.566Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T01:33:35.664Z:USER:taskMaster.c:6497:Temperature: 24.0 C
2025-10-30T01:42:43.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T01:43:18.453Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=234.9V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T01:43:30.503Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T01:48:36.070Z:USER:taskMaster.c:6497:Temperature: 24.0 C
2025-10-30T01:53:30.437Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T01:57:43.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T01:58:18.359Z:USER:taskMaster.c:6599:Socket #1: L1N=235.4V L2N=235.6V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T02:03:30.375Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-30T02:03:36.476Z:USER:taskMaster.c:6497:Temperature: 24.1 C
2025-10-30T02:12:43.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T02:13:18.261Z:USER:taskMaster.c:6599:Socket #1: L1N=233.8V L2N=235.0V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T02:13:30.312Z:INFO:active_lb.c:308:SMt:(7.0 1.0 5.0)A Free:(18.0 24.0 20.0)A ALB:(18.0 24.0 20.0)A
2025-10-30T02:18:36.980Z:USER:taskMaster.c:6497:Temperature: 23.8 C
2025-10-30T02:23:30.250Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(23.8 24.0 20.0)A
2025-10-30T02:27:43.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T02:28:18.167Z:USER:taskMaster.c:6599:Socket #1: L1N=234.9V L2N=235.5V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T02:33:30.183Z:INFO:active_lb.c:308:SMt:(8.0 1.0 5.0)A Free:(17.0 24.0 20.0)A ALB:(17.0 24.0 20.0)A
2025-10-30T02:33:37.234Z:USER:taskMaster.c:6497:Temperature: 23.8 C
2025-10-30T02:42:43.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T02:43:18.074Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=234.9V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T02:43:21.703Z:INFO:heap_trace.c:493:free: 61744/160768 (38.4%) min: 35456 (22.1%) alloc #: 216
2025-10-30T02:43:21.714Z:INFO:heap_trace.c:495:fragm: 33.5% 4K: 13.8% free blocks: # 23 largest: 41080
2025-10-30T02:43:30.121Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(19.2 24.0 20.0)A
2025-10-30T02:48:37.789Z:USER:taskMaster.c:6497:Temperature: 23.6 C
2025-10-30T02:53:30.058Z:INFO:active_lb.c:308:SMt:(10.0 1.0 5.0)A Free:(15.0 24.0 20.0)A ALB:(18.5 24.0 20.0)A
2025-10-30T02:57:43.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T02:58:17.976Z:USER:taskMaster.c:6599:Socket #1: L1N=234.4V L2N=234.6V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T03:03:29.996Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-30T03:03:38.242Z:USER:taskMaster.c:6497:Temperature: 23.6 C
2025-10-30T03:12:43.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T03:13:17.882Z:USER:taskMaster.c:6599:Socket #1: L1N=234.3V L2N=234.3V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T03:13:29.929Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(24.0 23.0 20.0)A ALB:(24.0 23.6 20.0)A
2025-10-30T03:18:38.648Z:USER:taskMaster.c:6497:Temperature: 23.2 C
2025-10-30T03:23:29.867Z:INFO:active_lb.c:308:SMt:(2.0 1.0 5.0)A Free:(23.0 24.0 20.0)A ALB:(22.9 24.0 20.0)A
2025-10-30T03:27:43.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T03:28:17.785Z:USER:taskMaster.c:6599:Socket #1: L1N=234.2V L2N=234.5V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T03:33:29.804Z:INFO:active_lb.c:308:SMt:(9.0 1.0 5.0)A Free:(16.0 24.0 20.0)A ALB:(16.1 24.0 20.0)A
2025-10-30T03:33:39.101Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-30T03:42:43.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T03:43:17.691Z:USER:taskMaster.c:6599:Socket #1: L1N=233.6V L2N=234.8V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T03:43:29.738Z:INFO:active_lb.c:308:SMt:(9.0 1.0 5.0)A Free:(16.0 24.0 20.0)A ALB:(16.0 24.0 20.0)A
2025-10-30T03:48:39.507Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-30T03:53:29.675Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-30T03:57:43.000Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T03:58:17.597Z:USER:taskMaster.c:6599:Socket #1: L1N=234.9V L2N=235.0V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T04:03:29.613Z:INFO:active_lb.c:308:SMt:(2.0 1.0 5.0)A Free:(23.0 24.0 20.0)A ALB:(23.6 24.0 20.0)A
2025-10-30T04:03:39.914Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-30T04:12:43.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T04:13:17.500Z:USER:taskMaster.c:6599:Socket #1: L1N=234.2V L2N=234.1V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T04:13:29.550Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-30T04:18:40.367Z:USER:taskMaster.c:6497:Temperature: 22.5 C
2025-10-30T04:23:29.484Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-30T04:27:43.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T04:28:17.406Z:USER:taskMaster.c:6599:Socket #1: L1N=233.0V L2N=233.4V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T04:33:29.421Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-30T04:33:40.769Z:USER:taskMaster.c:6497:Temperature: 22.5 C
2025-10-30T04:42:43.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T04:43:13.140Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-30T04:43:13.410Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-30T04:43:17.308Z:USER:taskMaster.c:6599:Socket #1: L1N=233.9V L2N=233.9V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T04:43:20.941Z:INFO:heap_trace.c:493:free: 61744/160768 (38.4%) min: 35456 (22.1%) alloc #: 216
2025-10-30T04:43:20.949Z:INFO:heap_trace.c:495:fragm: 33.5% 4K: 13.8% free blocks: # 23 largest: 41080
2025-10-30T04:43:29.359Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.1)A
2025-10-30T04:48:41.226Z:USER:taskMaster.c:6497:Temperature: 22.5 C
2025-10-30T04:53:29.292Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-30T04:57:43.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T04:58:17.214Z:USER:taskMaster.c:6599:Socket #1: L1N=232.7V L2N=232.8V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T05:03:29.230Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 23.8)A
2025-10-30T05:03:41.128Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-30T05:12:43.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T05:13:17.117Z:USER:taskMaster.c:6599:Socket #1: L1N=235.6V L2N=236.1V L3N=235.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T05:13:29.167Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T05:18:41.132Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-30T05:23:29.101Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T05:27:43.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T05:28:17.023Z:USER:taskMaster.c:6599:Socket #1: L1N=233.0V L2N=233.3V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T05:33:29.039Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-30T05:33:41.539Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-30T05:42:43.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T05:43:16.925Z:USER:taskMaster.c:6599:Socket #1: L1N=235.4V L2N=235.2V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T05:43:28.976Z:INFO:active_lb.c:308:SMt:(2.0 1.0 2.0)A Free:(23.0 24.0 23.0)A ALB:(23.1 24.0 23.1)A
2025-10-30T05:48:42.093Z:USER:taskMaster.c:6497:Temperature: 22.0 C
2025-10-30T05:53:28.910Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T05:57:41.867Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-30T05:57:42.167Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-30T05:57:42.476Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-30T05:57:42.546Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-10-30T05:57:42.914Z:SECURITY:web_functionalit:68:Changed '2059_00' from 1761803873538 => 1761803867385
2025-10-30T05:57:47.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T05:57:54.703Z:WARNING:db_base.c:383:Attempted out-of-bounds search
2025-10-30T05:57:54.710Z:ERROR:db_base.c:270:Unknown record (mem=1 reg=0x00000002 off=0x00000cc8 mag=0x12aa)
2025-10-30T05:57:54.722Z:WARNING:db_transaction.:238:Unexpected record @0x00000cc8
2025-10-30T05:57:54.730Z:WARNING:db_base.c:383:Attempted out-of-bounds search
2025-10-30T05:58:20.902Z:USER:taskMaster.c:6599:Socket #1: L1N=233.4V L2N=233.7V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T05:58:33.671Z:WARNING:taskWebClient.c:234:Client (fd=2) disconnected (r: -0x0)
2025-10-30T05:58:33.683Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-30T05:58:33.738Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-30T06:01:06.695Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-10-30T06:03:32.917Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T06:03:46.816Z:USER:taskMaster.c:6497:Temperature: 21.9 C
2025-10-30T06:11:06.730Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-10-30T06:12:47.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T06:13:20.808Z:USER:taskMaster.c:6599:Socket #1: L1N=237.5V L2N=237.9V L3N=238.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T06:13:32.855Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 24.0 23.9)A
2025-10-30T06:18:47.171Z:USER:taskMaster.c:6497:Temperature: 21.6 C
2025-10-30T06:21:06.667Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-10-30T06:23:32.792Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T06:27:47.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T06:28:20.710Z:USER:taskMaster.c:6599:Socket #1: L1N=235.1V L2N=235.3V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T06:33:32.726Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T06:33:47.578Z:USER:taskMaster.c:6497:Temperature: 21.9 C
2025-10-30T06:42:47.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T06:43:20.617Z:USER:taskMaster.c:6599:Socket #1: L1N=233.9V L2N=233.4V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T06:43:24.246Z:INFO:heap_trace.c:493:free: 61664/160768 (38.4%) min: 35264 (21.9%) alloc #: 218
2025-10-30T06:43:24.257Z:INFO:heap_trace.c:495:fragm: 33.4% 4K: 13.6% free blocks: # 23 largest: 41080
2025-10-30T06:43:32.664Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.6 24.0 24.0)A
2025-10-30T06:48:48.031Z:USER:taskMaster.c:6497:Temperature: 22.0 C
2025-10-30T06:53:32.601Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T06:57:47.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T06:58:20.519Z:USER:taskMaster.c:6599:Socket #1: L1N=236.1V L2N=235.8V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T07:03:32.535Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T07:03:48.433Z:USER:taskMaster.c:6497:Temperature: 21.9 C
2025-10-30T07:12:47.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T07:13:20.425Z:USER:taskMaster.c:6599:Socket #1: L1N=234.6V L2N=233.8V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T07:13:32.472Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T07:18:48.890Z:USER:taskMaster.c:6497:Temperature: 22.0 C
2025-10-30T07:23:32.410Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.1 24.0 24.0)A
2025-10-30T07:27:47.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T07:28:20.328Z:USER:taskMaster.c:6599:Socket #1: L1N=235.6V L2N=235.3V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T07:33:32.343Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(23.6 23.0 24.0)A
2025-10-30T07:33:49.292Z:USER:taskMaster.c:6497:Temperature: 22.0 C
2025-10-30T07:42:47.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T07:43:20.234Z:USER:taskMaster.c:6599:Socket #1: L1N=236.0V L2N=236.4V L3N=236.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T07:43:32.281Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T07:48:49.597Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-30T07:53:32.218Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(25.1 24.0 24.0)A
2025-10-30T07:57:47.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T07:58:20.136Z:USER:taskMaster.c:6599:Socket #1: L1N=235.5V L2N=236.6V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T08:03:32.152Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(24.0 26.0 24.0)A ALB:(24.0 26.0 24.0)A
2025-10-30T08:03:50.203Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-30T08:12:47.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T08:13:20.039Z:USER:taskMaster.c:6599:Socket #1: L1N=236.8V L2N=237.5V L3N=236.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T08:13:32.089Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 26.0 24.0)A
2025-10-30T08:18:50.605Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-30T08:23:32.027Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.2 24.0 24.0)A
2025-10-30T08:27:47.000Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T08:28:19.945Z:USER:taskMaster.c:6599:Socket #1: L1N=232.7V L2N=233.0V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T08:33:31.960Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T08:33:51.109Z:USER:taskMaster.c:6497:Temperature: 22.6 C
2025-10-30T08:42:47.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T08:43:15.515Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-30T08:43:15.785Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-30T08:43:19.851Z:USER:taskMaster.c:6599:Socket #1: L1N=234.3V L2N=234.4V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T08:43:23.480Z:INFO:heap_trace.c:493:free: 61504/160768 (38.3%) min: 35264 (21.9%) alloc #: 220
2025-10-30T08:43:23.492Z:INFO:heap_trace.c:495:fragm: 33.2% 4K: 13.4% free blocks: # 21 largest: 41080
2025-10-30T08:43:31.898Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-30T08:43:31.949Z:INFO:comFaults.c:482:Reset fault status
2025-10-30T08:48:51.515Z:USER:taskMaster.c:6497:Temperature: 23.0 C
2025-10-30T08:53:31.835Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-30T08:57:47.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T08:58:19.753Z:USER:taskMaster.c:6599:Socket #1: L1N=235.6V L2N=236.8V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T09:03:31.769Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.4 24.0 24.0)A
2025-10-30T09:03:51.917Z:USER:taskMaster.c:6497:Temperature: 23.4 C
2025-10-30T09:12:47.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T09:13:19.660Z:USER:taskMaster.c:6599:Socket #1: L1N=235.2V L2N=235.8V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T09:13:31.707Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-30T09:18:52.375Z:USER:taskMaster.c:6497:Temperature: 23.5 C
2025-10-30T09:23:31.644Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(25.9 24.0 24.0)A
2025-10-30T09:27:47.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T09:28:19.562Z:USER:taskMaster.c:6599:Socket #1: L1N=232.4V L2N=233.3V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T09:33:31.582Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(24.9 24.0 24.0)A
2025-10-30T09:33:52.878Z:USER:taskMaster.c:6497:Temperature: 24.0 C
2025-10-30T09:42:47.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T09:43:19.468Z:USER:taskMaster.c:6599:Socket #1: L1N=234.6V L2N=234.7V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T09:43:31.515Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 25.3 24.0)A
2025-10-30T09:48:53.234Z:USER:taskMaster.c:6497:Temperature: 24.0 C
2025-10-30T09:53:31.453Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.3 24.0)A
2025-10-30T09:57:47.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T09:58:19.375Z:USER:taskMaster.c:6599:Socket #1: L1N=238.7V L2N=238.8V L3N=239.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T10:03:31.390Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 1.0)A Free:(26.0 27.0 24.0)A ALB:(26.0 26.9 24.0)A
2025-10-30T10:03:53.937Z:USER:taskMaster.c:6497:Temperature: 24.2 C
2025-10-30T10:12:47.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T10:13:19.277Z:USER:taskMaster.c:6599:Socket #1: L1N=236.0V L2N=236.3V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T10:13:31.328Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.1 24.0)A
2025-10-30T10:18:54.542Z:USER:taskMaster.c:6497:Temperature: 24.8 C
2025-10-30T10:23:31.261Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-30T10:27:47.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T10:28:19.183Z:USER:taskMaster.c:6599:Socket #1: L1N=234.5V L2N=234.8V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T10:33:31.199Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 26.1 24.0)A
2025-10-30T10:33:54.847Z:USER:taskMaster.c:6497:Temperature: 24.8 C
2025-10-30T10:42:47.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T10:43:19.089Z:USER:taskMaster.c:6599:Socket #1: L1N=232.3V L2N=231.3V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T10:43:22.718Z:INFO:heap_trace.c:493:free: 61664/160768 (38.4%) min: 35264 (21.9%) alloc #: 218
2025-10-30T10:43:22.730Z:INFO:heap_trace.c:495:fragm: 33.4% 4K: 13.6% free blocks: # 23 largest: 41080
2025-10-30T10:43:31.136Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 23.8)A
2025-10-30T10:48:54.953Z:USER:taskMaster.c:6497:Temperature: 24.9 C
2025-10-30T10:53:31.074Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-30T10:57:47.046Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T10:58:18.992Z:USER:taskMaster.c:6599:Socket #1: L1N=235.1V L2N=235.0V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T11:03:31.011Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 1.0)A Free:(26.0 27.0 24.0)A ALB:(24.8 26.4 24.0)A
2025-10-30T11:03:55.359Z:USER:taskMaster.c:6497:Temperature: 25.1 C
2025-10-30T11:12:47.000Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T11:13:18.898Z:USER:taskMaster.c:6599:Socket #1: L1N=234.3V L2N=234.6V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T11:13:30.949Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-30T11:18:55.812Z:USER:taskMaster.c:6497:Temperature: 25.1 C
2025-10-30T11:23:30.933Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 25.1 24.0)A
2025-10-30T11:27:47.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T11:28:18.804Z:USER:taskMaster.c:6599:Socket #1: L1N=236.4V L2N=235.8V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T11:33:30.871Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 26.0 24.0)A
2025-10-30T11:33:56.269Z:USER:taskMaster.c:6497:Temperature: 25.0 C
2025-10-30T11:42:47.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T11:43:18.707Z:USER:taskMaster.c:6599:Socket #1: L1N=233.9V L2N=233.6V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T11:43:30.804Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(24.0 26.0 24.0)A ALB:(24.1 26.0 24.0)A
2025-10-30T11:48:56.671Z:USER:taskMaster.c:6497:Temperature: 25.5 C
2025-10-30T11:53:30.742Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 2.0)A Free:(24.0 26.0 23.0)A ALB:(24.5 26.0 23.6)A
2025-10-30T11:57:47.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T11:58:18.613Z:USER:taskMaster.c:6599:Socket #1: L1N=235.3V L2N=235.5V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T12:03:30.679Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(24.0 26.0 24.0)A ALB:(24.7 26.0 24.0)A
2025-10-30T12:03:57.328Z:USER:taskMaster.c:6497:Temperature: 25.6 C
2025-10-30T12:12:47.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T12:13:18.519Z:USER:taskMaster.c:6599:Socket #1: L1N=232.1V L2N=232.0V L3N=230.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T12:13:30.617Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.3 24.0 24.0)A
2025-10-30T12:18:57.531Z:USER:taskMaster.c:6497:Temperature: 25.2 C
2025-10-30T12:23:30.554Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(25.2 24.1 24.0)A
2025-10-30T12:27:47.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T12:28:18.421Z:USER:taskMaster.c:6599:Socket #1: L1N=235.8V L2N=236.3V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T12:33:30.488Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.3 24.0)A
2025-10-30T12:33:58.386Z:USER:taskMaster.c:6497:Temperature: 25.6 C
2025-10-30T12:42:47.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T12:43:13.792Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-30T12:43:14.062Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-30T12:43:18.328Z:USER:taskMaster.c:6599:Socket #1: L1N=237.9V L2N=237.6V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T12:43:21.957Z:INFO:heap_trace.c:493:free: 61664/160768 (38.4%) min: 35264 (21.9%) alloc #: 218
2025-10-30T12:43:21.968Z:INFO:heap_trace.c:495:fragm: 33.4% 4K: 13.6% free blocks: # 23 largest: 41080
2025-10-30T12:43:30.425Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 25.9 24.0)A
2025-10-30T12:48:58.390Z:USER:taskMaster.c:6497:Temperature: 25.6 C
2025-10-30T12:53:30.363Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 26.0 24.0)A
2025-10-30T12:57:47.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T12:58:18.234Z:USER:taskMaster.c:6599:Socket #1: L1N=237.9V L2N=238.5V L3N=237.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T13:03:30.300Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(25.6 26.3 24.0)A
2025-10-30T13:03:58.847Z:USER:taskMaster.c:6497:Temperature: 26.0 C
2025-10-30T13:12:47.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T13:13:18.136Z:USER:taskMaster.c:6599:Socket #1: L1N=238.1V L2N=238.1V L3N=237.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T13:13:30.238Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(27.0 27.0 24.0)A ALB:(27.0 27.6 24.0)A
2025-10-30T13:18:59.300Z:USER:taskMaster.c:6497:Temperature: 25.6 C
2025-10-30T13:23:30.171Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 25.6 24.0)A
2025-10-30T13:27:47.046Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T13:28:18.042Z:USER:taskMaster.c:6599:Socket #1: L1N=237.7V L2N=238.0V L3N=237.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T13:33:30.109Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(27.0 27.0 24.0)A ALB:(27.0 27.0 24.0)A
2025-10-30T13:33:59.906Z:USER:taskMaster.c:6497:Temperature: 25.8 C
2025-10-30T13:42:47.000Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T13:43:17.949Z:USER:taskMaster.c:6599:Socket #1: L1N=237.3V L2N=236.7V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T13:43:30.046Z:INFO:active_lb.c:308:SMt:(1.0 -2.0 1.0)A Free:(24.0 27.0 24.0)A ALB:(26.1 27.0 24.0)A
2025-10-30T13:49:00.113Z:USER:taskMaster.c:6497:Temperature: 25.9 C
2025-10-30T13:53:29.984Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 1.0)A Free:(26.0 27.0 24.0)A ALB:(26.0 26.9 24.0)A
2025-10-30T13:57:47.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T13:58:17.851Z:USER:taskMaster.c:6599:Socket #1: L1N=236.3V L2N=236.1V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T14:03:29.921Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.1 24.0)A
2025-10-30T14:04:00.515Z:USER:taskMaster.c:6497:Temperature: 26.0 C
2025-10-30T14:12:47.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T14:13:17.757Z:USER:taskMaster.c:6599:Socket #1: L1N=234.8V L2N=235.3V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T14:13:29.855Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.7 24.0 24.0)A
2025-10-30T14:19:00.824Z:USER:taskMaster.c:6497:Temperature: 25.8 C
2025-10-30T14:23:29.792Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(25.7 24.0 24.0)A
2025-10-30T14:27:47.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T14:28:17.664Z:USER:taskMaster.c:6599:Socket #1: L1N=237.6V L2N=237.7V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T14:33:29.730Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.1 24.0 24.0)A
2025-10-30T14:34:01.328Z:USER:taskMaster.c:6497:Temperature: 25.8 C
2025-10-30T14:37:45.941Z:COM:ocpp_rpc.c:715:-> [2,"278","Heartbeat",{}]
2025-10-30T14:37:46.039Z:COM:ocpp_rpc.c:1292:<- [3,"278",{"currentTime":"2025-10-30T14:37:47.966Z"}]
2025-10-30T14:42:47.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T14:43:18.515Z:USER:taskMaster.c:6599:Socket #1: L1N=235.5V L2N=235.5V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T14:43:22.144Z:INFO:heap_trace.c:493:free: 61664/160768 (38.4%) min: 35264 (21.9%) alloc #: 218
2025-10-30T14:43:22.156Z:INFO:heap_trace.c:495:fragm: 33.4% 4K: 13.6% free blocks: # 23 largest: 41080
2025-10-30T14:43:30.613Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 26.0 24.0)A
2025-10-30T14:49:03.082Z:USER:taskMaster.c:6497:Temperature: 25.6 C
2025-10-30T14:53:30.550Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(24.0 26.0 24.0)A ALB:(24.7 26.0 24.0)A
2025-10-30T14:57:47.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T14:58:18.421Z:USER:taskMaster.c:6599:Socket #1: L1N=234.8V L2N=234.9V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T15:03:30.488Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(25.1 24.0 24.0)A
2025-10-30T15:04:03.535Z:USER:taskMaster.c:6497:Temperature: 25.8 C
2025-10-30T15:12:47.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T15:12:47.179Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000001, address 0x00001000 (1)
2025-10-30T15:12:47.191Z:INFO:db_transaction.:181:Resetting nextToDoItem
2025-10-30T15:13:18.328Z:USER:taskMaster.c:6599:Socket #1: L1N=234.6V L2N=235.1V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T15:13:30.425Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(24.0 26.0 24.0)A ALB:(24.6 24.8 24.0)A
2025-10-30T15:19:03.992Z:USER:taskMaster.c:6497:Temperature: 25.5 C
2025-10-30T15:23:30.363Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.5 24.1 24.0)A
2025-10-30T15:27:47.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T15:28:18.230Z:USER:taskMaster.c:6599:Socket #1: L1N=232.0V L2N=233.4V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T15:33:30.296Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T15:34:04.394Z:USER:taskMaster.c:6497:Temperature: 25.4 C
2025-10-30T15:42:47.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T15:43:18.136Z:USER:taskMaster.c:6599:Socket #1: L1N=232.7V L2N=232.7V L3N=231.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T15:43:30.234Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 21.6 24.0)A
2025-10-30T15:49:04.800Z:USER:taskMaster.c:6497:Temperature: 25.4 C
2025-10-30T15:53:30.171Z:INFO:active_lb.c:308:SMt:(2.0 5.0 1.0)A Free:(23.0 20.0 24.0)A ALB:(23.0 20.0 24.0)A
2025-10-30T15:57:47.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T15:58:18.042Z:USER:taskMaster.c:6599:Socket #1: L1N=231.4V L2N=232.3V L3N=231.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T16:03:30.109Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(24.0 21.0 24.0)A ALB:(24.0 20.4 23.2)A
2025-10-30T16:04:05.355Z:USER:taskMaster.c:6497:Temperature: 25.2 C
2025-10-30T16:12:47.000Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T16:13:17.945Z:USER:taskMaster.c:6599:Socket #1: L1N=236.4V L2N=235.7V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T16:13:30.046Z:INFO:active_lb.c:308:SMt:(5.0 4.0 2.0)A Free:(20.0 21.0 23.0)A ALB:(20.0 21.0 10.0)A
2025-10-30T16:19:05.808Z:USER:taskMaster.c:6497:Temperature: 25.0 C
2025-10-30T16:23:29.980Z:INFO:active_lb.c:308:SMt:(2.0 4.0 1.0)A Free:(23.0 21.0 24.0)A ALB:(23.0 22.0 21.0)A
2025-10-30T16:24:15.289Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-10-30T16:27:47.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T16:28:17.851Z:USER:taskMaster.c:6599:Socket #1: L1N=233.7V L2N=232.1V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T16:33:29.917Z:INFO:active_lb.c:308:SMt:(2.0 3.0 10.0)A Free:(23.0 22.0 15.0)A ALB:(23.0 22.0 16.9)A
2025-10-30T16:34:06.066Z:USER:taskMaster.c:6497:Temperature: 24.6 C
2025-10-30T16:34:15.222Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-10-30T16:42:47.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T16:43:14.019Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-30T16:43:14.292Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-30T16:43:17.757Z:USER:taskMaster.c:6599:Socket #1: L1N=233.6V L2N=232.9V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T16:43:21.386Z:INFO:heap_trace.c:493:free: 61664/160768 (38.4%) min: 35264 (21.9%) alloc #: 218
2025-10-30T16:43:21.398Z:INFO:heap_trace.c:495:fragm: 33.4% 4K: 13.6% free blocks: # 23 largest: 41080
2025-10-30T16:43:29.855Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(23.0 22.0 24.0)A ALB:(22.9 22.0 23.9)A
2025-10-30T16:44:15.261Z:INFO:taskLeds.c:338:Brightness set to 8%
2025-10-30T16:49:06.769Z:USER:taskMaster.c:6497:Temperature: 24.2 C
2025-10-30T16:53:29.792Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(23.8 22.0 22.2)A
2025-10-30T16:57:47.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T16:58:17.660Z:USER:taskMaster.c:6599:Socket #1: L1N=231.0V L2N=230.7V L3N=229.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T17:03:29.726Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(23.0 22.0 24.0)A ALB:(23.2 22.0 24.0)A
2025-10-30T17:04:06.925Z:USER:taskMaster.c:6497:Temperature: 24.1 C
2025-10-30T17:12:47.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T17:13:17.566Z:USER:taskMaster.c:6599:Socket #1: L1N=231.3V L2N=230.9V L3N=230.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T17:13:29.664Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(23.0 22.0 24.0)A ALB:(23.0 22.0 24.0)A
2025-10-30T17:19:07.378Z:USER:taskMaster.c:6497:Temperature: 23.9 C
2025-10-30T17:23:29.601Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-30T17:27:47.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T17:28:17.472Z:USER:taskMaster.c:6599:Socket #1: L1N=232.7V L2N=232.7V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T17:33:29.539Z:INFO:active_lb.c:308:SMt:(3.0 3.0 1.0)A Free:(22.0 22.0 24.0)A ALB:(24.0 22.2 24.0)A
2025-10-30T17:34:07.835Z:USER:taskMaster.c:6497:Temperature: 23.6 C
2025-10-30T17:42:47.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T17:43:17.375Z:USER:taskMaster.c:6599:Socket #1: L1N=233.7V L2N=234.3V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T17:43:29.472Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-30T17:49:08.289Z:USER:taskMaster.c:6497:Temperature: 23.5 C
2025-10-30T17:53:29.410Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-30T17:57:47.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T17:58:17.281Z:USER:taskMaster.c:6599:Socket #1: L1N=231.5V L2N=231.7V L3N=232.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T18:03:29.347Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(23.8 22.0 24.0)A
2025-10-30T18:04:08.742Z:USER:taskMaster.c:6497:Temperature: 23.6 C
2025-10-30T18:12:47.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T18:13:17.183Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=233.9V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T18:13:29.285Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-30T18:19:09.148Z:USER:taskMaster.c:6497:Temperature: 23.2 C
2025-10-30T18:23:29.218Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-30T18:27:47.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T18:28:17.089Z:USER:taskMaster.c:6599:Socket #1: L1N=232.2V L2N=233.1V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T18:33:29.156Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 22.4 24.0)A
2025-10-30T18:34:09.554Z:USER:taskMaster.c:6497:Temperature: 23.4 C
2025-10-30T18:42:47.046Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T18:43:16.996Z:USER:taskMaster.c:6599:Socket #1: L1N=234.6V L2N=235.4V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T18:43:20.625Z:INFO:heap_trace.c:493:free: 61664/160768 (38.4%) min: 35264 (21.9%) alloc #: 218
2025-10-30T18:43:20.636Z:INFO:heap_trace.c:495:fragm: 33.4% 4K: 13.6% free blocks: # 23 largest: 41080
2025-10-30T18:43:29.093Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-30T18:49:10.007Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-30T18:53:29.031Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(23.4 23.0 24.0)A
2025-10-30T18:57:47.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T18:58:16.898Z:USER:taskMaster.c:6599:Socket #1: L1N=235.2V L2N=234.7V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T19:03:28.964Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(24.0 21.0 24.0)A ALB:(24.0 20.1 24.0)A
2025-10-30T19:04:10.414Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-30T19:12:47.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T19:13:16.804Z:USER:taskMaster.c:6599:Socket #1: L1N=231.9V L2N=231.7V L3N=231.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T19:13:28.902Z:INFO:active_lb.c:308:SMt:(1.0 4.0 2.0)A Free:(24.0 21.0 23.0)A ALB:(24.0 21.0 23.2)A
2025-10-30T19:19:11.214Z:USER:taskMaster.c:6497:Temperature: 23.0 C
2025-10-30T19:23:28.839Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 22.0 24.0)A
2025-10-30T19:27:47.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T19:28:16.707Z:USER:taskMaster.c:6599:Socket #1: L1N=233.6V L2N=233.4V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T19:33:28.773Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(23.0 22.0 24.0)A ALB:(23.2 21.4 24.0)A
2025-10-30T19:34:11.222Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-30T19:42:47.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T19:43:16.613Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=235.1V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T19:43:28.710Z:INFO:active_lb.c:308:SMt:(1.0 4.0 2.0)A Free:(24.0 21.0 23.0)A ALB:(24.0 21.0 23.0)A
2025-10-30T19:49:11.675Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-30T19:53:28.648Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(24.0 21.0 24.0)A ALB:(24.0 21.0 24.0)A
2025-10-30T19:57:47.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T19:58:16.519Z:USER:taskMaster.c:6599:Socket #1: L1N=233.7V L2N=233.9V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T20:03:28.585Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(24.0 21.0 24.0)A ALB:(24.0 21.0 24.0)A
2025-10-30T20:04:12.128Z:USER:taskMaster.c:6497:Temperature: 22.6 C
2025-10-30T20:12:47.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T20:13:16.421Z:USER:taskMaster.c:6599:Socket #1: L1N=231.5V L2N=231.9V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T20:13:28.519Z:INFO:active_lb.c:308:SMt:(2.0 4.0 1.0)A Free:(23.0 21.0 24.0)A ALB:(23.0 21.0 24.0)A
2025-10-30T20:19:12.535Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-30T20:23:28.457Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 21.9 24.0)A
2025-10-30T20:27:47.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T20:28:16.328Z:USER:taskMaster.c:6599:Socket #1: L1N=234.8V L2N=234.5V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T20:33:28.394Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(24.0 21.0 24.0)A ALB:(24.0 21.3 24.0)A
2025-10-30T20:34:13.140Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-30T20:42:47.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T20:43:12.281Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-30T20:43:12.550Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-30T20:43:16.230Z:USER:taskMaster.c:6599:Socket #1: L1N=234.5V L2N=234.4V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T20:43:19.863Z:INFO:heap_trace.c:493:free: 61664/160768 (38.4%) min: 35264 (21.9%) alloc #: 218
2025-10-30T20:43:19.871Z:INFO:heap_trace.c:495:fragm: 33.4% 4K: 13.6% free blocks: # 23 largest: 41080
2025-10-30T20:43:28.328Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(24.0 21.0 24.0)A ALB:(24.0 21.6 24.0)A
2025-10-30T20:43:28.339Z:INFO:comFaults.c:482:Reset fault status
2025-10-30T20:49:13.445Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-30T20:53:28.265Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(23.0 22.0 24.0)A ALB:(22.4 21.4 24.0)A
2025-10-30T20:57:47.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T20:58:16.136Z:USER:taskMaster.c:6599:Socket #1: L1N=234.9V L2N=234.8V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T21:03:28.203Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(24.0 21.0 24.0)A ALB:(24.0 21.0 24.0)A
2025-10-30T21:04:13.449Z:USER:taskMaster.c:6497:Temperature: 22.8 C
2025-10-30T21:12:47.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T21:13:16.039Z:USER:taskMaster.c:6599:Socket #1: L1N=235.1V L2N=234.8V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T21:13:28.140Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(24.0 21.0 24.0)A ALB:(24.0 21.0 24.0)A
2025-10-30T21:19:14.300Z:USER:taskMaster.c:6497:Temperature: 22.6 C
2025-10-30T21:23:28.125Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(24.0 21.0 24.0)A ALB:(24.0 21.6 24.0)A
2025-10-30T21:27:47.046Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T21:28:15.945Z:USER:taskMaster.c:6599:Socket #1: L1N=233.5V L2N=233.3V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T21:33:28.062Z:INFO:active_lb.c:308:SMt:(2.0 4.0 1.0)A Free:(23.0 21.0 24.0)A ALB:(24.0 21.2 24.0)A
2025-10-30T21:34:14.707Z:USER:taskMaster.c:6497:Temperature: 22.5 C
2025-10-30T21:42:47.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T21:43:15.847Z:USER:taskMaster.c:6599:Socket #1: L1N=234.2V L2N=234.2V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T21:43:27.996Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(24.0 22.0 24.0)A ALB:(24.0 21.0 24.0)A
2025-10-30T21:49:15.160Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-30T21:53:27.933Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(24.0 21.0 24.0)A ALB:(24.0 21.1 24.0)A
2025-10-30T21:57:47.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T21:58:15.753Z:USER:taskMaster.c:6599:Socket #1: L1N=235.7V L2N=236.3V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T22:03:27.871Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.0 23.0 24.0)A
2025-10-30T22:04:15.566Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-30T22:12:47.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T22:13:15.656Z:USER:taskMaster.c:6599:Socket #1: L1N=234.6V L2N=234.2V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T22:13:27.804Z:INFO:active_lb.c:308:SMt:(1.0 6.0 1.0)A Free:(24.0 19.0 24.0)A ALB:(24.0 18.8 24.0)A
2025-10-30T22:19:16.019Z:USER:taskMaster.c:6497:Temperature: 22.1 C
2025-10-30T22:23:27.742Z:INFO:active_lb.c:308:SMt:(1.0 6.0 1.0)A Free:(24.0 19.0 24.0)A ALB:(24.0 19.0 24.0)A
2025-10-30T22:27:47.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T22:28:15.562Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=233.8V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T22:33:27.679Z:INFO:active_lb.c:308:SMt:(1.0 7.0 1.0)A Free:(24.0 18.0 24.0)A ALB:(24.0 18.0 24.0)A
2025-10-30T22:34:16.824Z:USER:taskMaster.c:6497:Temperature: 22.0 C
2025-10-30T22:42:47.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T22:43:15.464Z:USER:taskMaster.c:6599:Socket #1: L1N=236.0V L2N=235.8V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T22:43:19.097Z:INFO:heap_trace.c:493:free: 61664/160768 (38.4%) min: 35264 (21.9%) alloc #: 218
2025-10-30T22:43:19.109Z:INFO:heap_trace.c:495:fragm: 33.4% 4K: 13.6% free blocks: # 23 largest: 41080
2025-10-30T22:43:27.613Z:INFO:active_lb.c:308:SMt:(1.0 6.0 1.0)A Free:(24.0 19.0 24.0)A ALB:(24.0 19.0 24.0)A
2025-10-30T22:49:16.929Z:USER:taskMaster.c:6497:Temperature: 22.0 C
2025-10-30T22:53:27.550Z:INFO:active_lb.c:308:SMt:(1.0 6.0 1.0)A Free:(24.0 19.0 24.0)A ALB:(24.0 19.0 24.0)A
2025-10-30T22:57:47.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T22:58:15.371Z:USER:taskMaster.c:6599:Socket #1: L1N=236.6V L2N=236.5V L3N=236.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T23:03:27.488Z:INFO:active_lb.c:308:SMt:(1.0 6.0 1.0)A Free:(24.0 19.0 24.0)A ALB:(24.0 19.0 24.0)A
2025-10-30T23:04:17.433Z:USER:taskMaster.c:6497:Temperature: 21.9 C
2025-10-30T23:12:47.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T23:13:15.277Z:USER:taskMaster.c:6599:Socket #1: L1N=237.6V L2N=236.7V L3N=237.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T23:13:27.425Z:INFO:active_lb.c:308:SMt:(1.0 6.0 1.0)A Free:(24.0 19.0 24.0)A ALB:(24.0 19.0 24.0)A
2025-10-30T23:19:17.835Z:USER:taskMaster.c:6497:Temperature: 22.0 C
2025-10-30T23:23:27.359Z:INFO:active_lb.c:308:SMt:(1.0 6.0 1.0)A Free:(24.0 19.0 24.0)A ALB:(24.0 19.0 24.0)A
2025-10-30T23:27:47.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T23:28:15.179Z:USER:taskMaster.c:6599:Socket #1: L1N=233.5V L2N=233.3V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T23:33:27.296Z:INFO:active_lb.c:308:SMt:(1.0 6.0 1.0)A Free:(24.0 19.0 24.0)A ALB:(24.0 19.0 24.0)A
2025-10-30T23:34:18.289Z:USER:taskMaster.c:6497:Temperature: 22.0 C
2025-10-30T23:42:47.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T23:43:15.085Z:USER:taskMaster.c:6599:Socket #1: L1N=233.7V L2N=234.0V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-30T23:43:27.230Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T23:49:18.746Z:USER:taskMaster.c:6497:Temperature: 21.6 C
2025-10-30T23:53:27.167Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-30T23:57:47.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-30T23:58:14.988Z:USER:taskMaster.c:6599:Socket #1: L1N=234.0V L2N=234.0V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T00:03:27.105Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-31T00:04:19.199Z:USER:taskMaster.c:6497:Temperature: 21.6 C
2025-10-31T00:12:47.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T00:13:14.890Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=234.1V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T00:13:27.039Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.0 24.0 24.0)A
2025-10-31T00:19:19.605Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-31T00:23:26.976Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.4 24.0 24.0)A
2025-10-31T00:27:47.000Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T00:28:14.796Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=234.7V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T00:33:26.914Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-31T00:34:20.058Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-31T00:42:47.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T00:43:10.558Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-31T00:43:10.828Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-31T00:43:14.699Z:USER:taskMaster.c:6599:Socket #1: L1N=235.4V L2N=235.1V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T00:43:18.332Z:INFO:heap_trace.c:493:free: 61664/160768 (38.4%) min: 35264 (21.9%) alloc #: 218
2025-10-31T00:43:18.339Z:INFO:heap_trace.c:495:fragm: 33.4% 4K: 13.6% free blocks: # 23 largest: 41080
2025-10-31T00:43:26.847Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-31T00:49:20.460Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-31T00:53:26.785Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-31T00:57:47.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T00:58:14.605Z:USER:taskMaster.c:6599:Socket #1: L1N=234.4V L2N=234.7V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T01:03:26.722Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-31T01:04:20.867Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-31T01:12:47.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T01:13:14.507Z:USER:taskMaster.c:6599:Socket #1: L1N=234.5V L2N=234.3V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T01:13:26.656Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-31T01:19:21.371Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-31T01:23:26.593Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-31T01:27:47.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T01:28:14.414Z:USER:taskMaster.c:6599:Socket #1: L1N=234.2V L2N=234.8V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T01:33:26.531Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-31T01:34:21.773Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-31T01:42:47.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T01:43:14.316Z:USER:taskMaster.c:6599:Socket #1: L1N=234.5V L2N=234.8V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T01:43:26.464Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-31T01:49:22.179Z:USER:taskMaster.c:6497:Temperature: 21.2 C
2025-10-31T01:53:26.402Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-31T01:57:47.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T01:58:14.222Z:USER:taskMaster.c:6599:Socket #1: L1N=235.0V L2N=235.0V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T02:03:26.335Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-31T02:04:22.632Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-31T02:12:47.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T02:13:14.125Z:USER:taskMaster.c:6599:Socket #1: L1N=235.2V L2N=235.1V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T02:13:26.273Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-31T02:19:23.136Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-31T02:23:26.210Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(24.0 23.0 20.0)A ALB:(24.0 23.4 20.0)A
2025-10-31T02:27:47.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T02:28:14.027Z:USER:taskMaster.c:6599:Socket #1: L1N=235.1V L2N=235.3V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T02:33:26.144Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 23.7 20.0)A
2025-10-31T02:34:23.539Z:USER:taskMaster.c:6497:Temperature: 21.2 C
2025-10-31T02:42:47.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T02:43:13.933Z:USER:taskMaster.c:6599:Socket #1: L1N=235.3V L2N=235.2V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T02:43:17.562Z:INFO:heap_trace.c:493:free: 61664/160768 (38.4%) min: 35264 (21.9%) alloc #: 218
2025-10-31T02:43:17.574Z:INFO:heap_trace.c:495:fragm: 33.4% 4K: 13.6% free blocks: # 23 largest: 41080
2025-10-31T02:43:26.082Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-31T02:49:23.992Z:USER:taskMaster.c:6497:Temperature: 21.0 C
2025-10-31T02:53:26.019Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-31T02:57:47.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T02:58:13.835Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=234.8V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T03:03:25.953Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-31T03:04:24.449Z:USER:taskMaster.c:6497:Temperature: 21.1 C
2025-10-31T03:12:47.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T03:13:13.742Z:USER:taskMaster.c:6599:Socket #1: L1N=234.5V L2N=235.0V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T03:13:25.890Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-31T03:19:24.902Z:USER:taskMaster.c:6497:Temperature: 20.9 C
2025-10-31T03:23:25.824Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-31T03:27:47.046Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T03:28:13.644Z:USER:taskMaster.c:6599:Socket #1: L1N=233.7V L2N=233.9V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T03:33:25.761Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-31T03:34:25.355Z:USER:taskMaster.c:6497:Temperature: 20.9 C
2025-10-31T03:42:47.000Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T03:43:13.546Z:USER:taskMaster.c:6599:Socket #1: L1N=233.7V L2N=233.8V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T03:43:25.699Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(23.7 24.0 20.0)A
2025-10-31T03:49:25.757Z:USER:taskMaster.c:6497:Temperature: 21.0 C
2025-10-31T03:53:25.632Z:INFO:active_lb.c:308:SMt:(1.0 1.0 4.0)A Free:(24.0 24.0 21.0)A ALB:(24.0 24.0 20.7)A
2025-10-31T03:57:47.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T03:58:13.453Z:USER:taskMaster.c:6599:Socket #1: L1N=233.2V L2N=233.1V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T04:03:25.570Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.4)A
2025-10-31T04:04:26.214Z:USER:taskMaster.c:6497:Temperature: 21.0 C
2025-10-31T04:12:47.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T04:13:13.355Z:USER:taskMaster.c:6599:Socket #1: L1N=236.6V L2N=236.4V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T04:13:25.503Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-31T04:19:26.714Z:USER:taskMaster.c:6497:Temperature: 20.9 C
2025-10-31T04:23:25.441Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-31T04:27:47.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T04:28:13.261Z:USER:taskMaster.c:6599:Socket #1: L1N=235.7V L2N=236.2V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T04:33:25.378Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-31T04:34:27.218Z:USER:taskMaster.c:6497:Temperature: 21.0 C
2025-10-31T04:42:47.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T04:43:08.820Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-31T04:43:09.089Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-31T04:43:13.164Z:USER:taskMaster.c:6599:Socket #1: L1N=237.6V L2N=237.7V L3N=237.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T04:43:16.792Z:INFO:heap_trace.c:493:free: 61664/160768 (38.4%) min: 35264 (21.9%) alloc #: 218
2025-10-31T04:43:16.804Z:INFO:heap_trace.c:495:fragm: 33.4% 4K: 13.6% free blocks: # 23 largest: 41080
2025-10-31T04:43:25.312Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-31T04:49:27.675Z:USER:taskMaster.c:6497:Temperature: 20.8 C
2025-10-31T04:53:25.250Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(24.0 24.0 20.0)A ALB:(24.0 24.0 20.0)A
2025-10-31T04:57:47.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T04:58:13.070Z:USER:taskMaster.c:6599:Socket #1: L1N=235.8V L2N=236.1V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T05:03:25.183Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-31T05:04:28.128Z:USER:taskMaster.c:6497:Temperature: 20.8 C
2025-10-31T05:12:47.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T05:13:12.972Z:USER:taskMaster.c:6599:Socket #1: L1N=238.2V L2N=238.7V L3N=237.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T05:13:25.121Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-31T05:19:28.531Z:USER:taskMaster.c:6497:Temperature: 21.0 C
2025-10-31T05:23:25.058Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-31T05:27:47.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T05:28:12.875Z:USER:taskMaster.c:6599:Socket #1: L1N=233.4V L2N=233.7V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T05:33:24.992Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-31T05:34:28.937Z:USER:taskMaster.c:6497:Temperature: 20.9 C
2025-10-31T05:42:47.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T05:43:12.781Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=235.5V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T05:43:24.929Z:INFO:active_lb.c:308:SMt:(3.0 1.0 1.0)A Free:(22.0 24.0 24.0)A ALB:(20.5 24.0 24.0)A
2025-10-31T05:49:29.390Z:USER:taskMaster.c:6497:Temperature: 20.8 C
2025-10-31T05:53:24.863Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-31T05:57:47.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T05:58:12.683Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=234.9V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T06:02:56.265Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-10-31T06:03:24.800Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-31T06:04:29.843Z:USER:taskMaster.c:6497:Temperature: 20.9 C
2025-10-31T06:12:47.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T06:12:56.300Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-10-31T06:13:12.589Z:USER:taskMaster.c:6599:Socket #1: L1N=233.0V L2N=233.8V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T06:13:24.738Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-31T06:19:30.250Z:USER:taskMaster.c:6497:Temperature: 21.4 C
2025-10-31T06:22:56.238Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-10-31T06:23:24.671Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.0 24.0 23.0)A
2025-10-31T06:27:47.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T06:28:12.492Z:USER:taskMaster.c:6599:Socket #1: L1N=232.8V L2N=234.3V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T06:33:24.609Z:INFO:active_lb.c:308:SMt:(2.0 1.0 2.0)A Free:(23.0 24.0 23.0)A ALB:(23.1 24.0 23.0)A
2025-10-31T06:34:30.703Z:USER:taskMaster.c:6497:Temperature: 21.2 C
2025-10-31T06:42:47.000Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T06:43:12.394Z:USER:taskMaster.c:6599:Socket #1: L1N=235.8V L2N=236.3V L3N=235.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T06:43:16.027Z:INFO:heap_trace.c:493:free: 61664/160768 (38.4%) min: 35264 (21.9%) alloc #: 218
2025-10-31T06:43:16.039Z:INFO:heap_trace.c:495:fragm: 33.4% 4K: 13.6% free blocks: # 23 largest: 41080
2025-10-31T06:43:24.542Z:INFO:active_lb.c:308:SMt:(2.0 1.0 2.0)A Free:(23.0 24.0 23.0)A ALB:(23.1 24.0 23.0)A
2025-10-31T06:49:31.207Z:USER:taskMaster.c:6497:Temperature: 21.2 C
2025-10-31T06:53:24.480Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(23.7 24.0 22.9)A
2025-10-31T06:57:47.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T06:58:12.300Z:USER:taskMaster.c:6599:Socket #1: L1N=235.9V L2N=237.4V L3N=236.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T07:03:24.417Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(23.0 24.0 23.0)A
2025-10-31T07:04:31.609Z:USER:taskMaster.c:6497:Temperature: 21.5 C
2025-10-31T07:12:47.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T07:13:12.203Z:USER:taskMaster.c:6599:Socket #1: L1N=234.9V L2N=235.3V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T07:13:24.351Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.0 24.0 23.0)A
2025-10-31T07:19:31.617Z:USER:taskMaster.c:6497:Temperature: 21.6 C
2025-10-31T07:23:24.289Z:INFO:active_lb.c:308:SMt:(2.0 2.0 2.0)A Free:(23.0 23.0 23.0)A ALB:(23.6 23.1 23.0)A
2025-10-31T07:27:47.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T07:28:12.109Z:USER:taskMaster.c:6599:Socket #1: L1N=235.1V L2N=236.0V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T07:33:24.226Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(24.0 23.0 23.0)A ALB:(24.0 23.0 23.0)A
2025-10-31T07:34:31.667Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-31T07:42:47.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T07:43:12.011Z:USER:taskMaster.c:6599:Socket #1: L1N=233.7V L2N=233.9V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T07:43:24.160Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(23.2 24.0 23.0)A
2025-10-31T07:49:32.371Z:USER:taskMaster.c:6497:Temperature: 21.8 C
2025-10-31T07:53:24.097Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.0 24.0 23.0)A
2025-10-31T07:57:47.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T07:58:11.917Z:USER:taskMaster.c:6599:Socket #1: L1N=232.7V L2N=232.8V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T08:03:24.035Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.0 24.0 23.0)A
2025-10-31T08:04:32.425Z:USER:taskMaster.c:6497:Temperature: 22.0 C
2025-10-31T08:12:47.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T08:13:11.820Z:USER:taskMaster.c:6599:Socket #1: L1N=236.1V L2N=236.7V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T08:13:23.968Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(25.5 24.0 23.0)A
2025-10-31T08:19:33.031Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-31T08:23:23.906Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(24.0 23.0 23.0)A ALB:(24.4 23.0 23.0)A
2025-10-31T08:27:47.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T08:28:11.726Z:USER:taskMaster.c:6599:Socket #1: L1N=234.7V L2N=234.4V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T08:33:23.839Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(26.0 24.0 23.0)A
2025-10-31T08:34:33.632Z:USER:taskMaster.c:6497:Temperature: 22.2 C
2025-10-31T08:42:47.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T08:43:08.105Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-31T08:43:08.375Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-31T08:43:11.628Z:USER:taskMaster.c:6599:Socket #1: L1N=234.8V L2N=233.9V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T08:43:15.257Z:INFO:heap_trace.c:493:free: 61664/160768 (38.4%) min: 35264 (21.9%) alloc #: 218
2025-10-31T08:43:15.269Z:INFO:heap_trace.c:495:fragm: 33.4% 4K: 13.6% free blocks: # 23 largest: 41080
2025-10-31T08:43:23.777Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(25.3 24.0 23.0)A
2025-10-31T08:43:23.789Z:INFO:comFaults.c:482:Reset fault status
2025-10-31T08:49:33.687Z:USER:taskMaster.c:6497:Temperature: 22.4 C
2025-10-31T08:53:23.714Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(26.0 24.0 23.0)A
2025-10-31T08:57:47.035Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T08:58:11.535Z:USER:taskMaster.c:6599:Socket #1: L1N=232.7V L2N=232.6V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T09:03:23.648Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(26.0 24.0 23.0)A ALB:(26.0 24.0 23.0)A
2025-10-31T09:04:34.093Z:USER:taskMaster.c:6497:Temperature: 22.6 C
2025-10-31T09:12:47.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T09:13:11.437Z:USER:taskMaster.c:6599:Socket #1: L1N=235.3V L2N=234.7V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T09:13:23.585Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(26.0 23.0 24.0)A
2025-10-31T09:19:34.847Z:USER:taskMaster.c:6497:Temperature: 22.9 C
2025-10-31T09:23:23.523Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 1.0)A Free:(26.0 23.0 24.0)A ALB:(26.0 23.0 24.0)A
2025-10-31T09:27:47.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T09:28:11.343Z:USER:taskMaster.c:6599:Socket #1: L1N=237.7V L2N=236.7V L3N=237.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T09:33:23.460Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-31T09:34:34.953Z:USER:taskMaster.c:6497:Temperature: 23.1 C
2025-10-31T09:42:47.000Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T09:43:11.246Z:USER:taskMaster.c:6599:Socket #1: L1N=234.1V L2N=234.5V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T09:43:23.394Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-31T09:49:35.406Z:USER:taskMaster.c:6497:Temperature: 23.4 C
2025-10-31T09:53:23.332Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-31T09:57:47.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T09:58:11.152Z:USER:taskMaster.c:6599:Socket #1: L1N=234.5V L2N=235.0V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T10:03:23.269Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-31T10:04:35.859Z:USER:taskMaster.c:6497:Temperature: 23.6 C
2025-10-31T10:12:47.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T10:13:11.054Z:USER:taskMaster.c:6599:Socket #1: L1N=235.4V L2N=235.5V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T10:13:23.203Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 1.0)A Free:(26.0 23.0 24.0)A ALB:(25.7 23.0 24.0)A
2025-10-31T10:19:36.367Z:USER:taskMaster.c:6497:Temperature: 23.8 C
2025-10-31T10:23:23.140Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(24.0 23.0 24.0)A ALB:(24.4 23.0 24.0)A
2025-10-31T10:27:47.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T10:28:10.960Z:USER:taskMaster.c:6599:Socket #1: L1N=235.5V L2N=236.6V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T10:33:23.078Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(24.0 26.0 24.0)A ALB:(24.3 25.7 24.0)A
2025-10-31T10:34:36.769Z:USER:taskMaster.c:6497:Temperature: 24.2 C
2025-10-31T10:42:47.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T10:43:10.867Z:USER:taskMaster.c:6599:Socket #1: L1N=236.5V L2N=237.0V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T10:43:14.496Z:INFO:heap_trace.c:493:free: 61664/160768 (38.4%) min: 35264 (21.9%) alloc #: 218
2025-10-31T10:43:14.507Z:INFO:heap_trace.c:495:fragm: 33.4% 4K: 13.6% free blocks: # 23 largest: 41080
2025-10-31T10:43:23.015Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(24.0 26.0 24.0)A ALB:(25.2 26.0 24.0)A
2025-10-31T10:49:37.175Z:USER:taskMaster.c:6497:Temperature: 24.4 C
2025-10-31T10:53:22.949Z:INFO:active_lb.c:308:SMt:(2.0 -1.0 1.0)A Free:(23.0 26.0 24.0)A ALB:(23.1 26.0 24.0)A
2025-10-31T10:57:47.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T10:58:10.769Z:USER:taskMaster.c:6599:Socket #1: L1N=236.6V L2N=237.3V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T11:03:22.886Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 25.2 24.0)A
2025-10-31T11:04:37.582Z:USER:taskMaster.c:6497:Temperature: 24.8 C
2025-10-31T11:12:47.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T11:13:10.675Z:USER:taskMaster.c:6599:Socket #1: L1N=238.2V L2N=238.3V L3N=236.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T11:13:22.824Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-31T11:19:37.984Z:USER:taskMaster.c:6497:Temperature: 25.0 C
2025-10-31T11:23:22.761Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(24.0 26.0 24.0)A ALB:(24.0 25.6 24.0)A
2025-10-31T11:27:47.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T11:28:10.582Z:USER:taskMaster.c:6599:Socket #1: L1N=234.9V L2N=234.9V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T11:33:22.699Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 26.0 24.0)A
2025-10-31T11:34:38.390Z:USER:taskMaster.c:6497:Temperature: 25.4 C
2025-10-31T11:42:47.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T11:43:10.484Z:USER:taskMaster.c:6599:Socket #1: L1N=234.4V L2N=234.5V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T11:43:22.632Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.3 23.9)A
2025-10-31T11:49:38.792Z:USER:taskMaster.c:6497:Temperature: 25.1 C
2025-10-31T11:53:22.570Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 26.0 24.0)A
2025-10-31T11:57:47.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T11:58:10.390Z:USER:taskMaster.c:6599:Socket #1: L1N=234.3V L2N=234.2V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T12:03:22.507Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.5 24.0)A
2025-10-31T12:04:39.250Z:USER:taskMaster.c:6497:Temperature: 25.2 C
2025-10-31T12:12:47.046Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T12:13:10.296Z:USER:taskMaster.c:6599:Socket #1: L1N=234.2V L2N=234.1V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T12:13:22.445Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(26.0 26.0 24.0)A
2025-10-31T12:19:39.703Z:USER:taskMaster.c:6497:Temperature: 25.5 C
2025-10-31T12:23:22.378Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(26.0 26.0 24.0)A ALB:(25.8 24.9 24.0)A
2025-10-31T12:27:47.003Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T12:28:10.199Z:USER:taskMaster.c:6599:Socket #1: L1N=236.9V L2N=237.6V L3N=236.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T12:33:22.316Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 1.0)A Free:(26.0 27.0 24.0)A ALB:(26.0 26.9 24.0)A
2025-10-31T12:34:40.109Z:USER:taskMaster.c:6497:Temperature: 25.5 C
2025-10-31T12:42:47.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T12:43:06.378Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-31T12:43:06.648Z:INFO:taskCANopen.c:1775:Updated object 0x21b6, 8 bytes
2025-10-31T12:43:10.105Z:USER:taskMaster.c:6599:Socket #1: L1N=237.6V L2N=237.6V L3N=237.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T12:43:13.734Z:INFO:heap_trace.c:493:free: 61664/160768 (38.4%) min: 35264 (21.9%) alloc #: 218
2025-10-31T12:43:13.746Z:INFO:heap_trace.c:495:fragm: 33.4% 4K: 13.6% free blocks: # 23 largest: 41080
2025-10-31T12:43:22.253Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(27.0 27.0 24.0)A ALB:(26.0 26.0 24.0)A
2025-10-31T12:49:40.515Z:USER:taskMaster.c:6497:Temperature: 25.8 C
2025-10-31T12:53:22.191Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.1 23.9)A
2025-10-31T12:57:47.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T12:58:10.011Z:USER:taskMaster.c:6599:Socket #1: L1N=232.7V L2N=232.0V L3N=231.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T13:03:22.128Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-31T13:04:40.968Z:USER:taskMaster.c:6497:Temperature: 25.9 C
2025-10-31T13:12:47.019Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T13:13:09.914Z:USER:taskMaster.c:6599:Socket #1: L1N=233.8V L2N=234.1V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T13:13:22.062Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(26.0 24.0 24.0)A
2025-10-31T13:19:41.375Z:USER:taskMaster.c:6497:Temperature: 25.9 C
2025-10-31T13:23:22.000Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(25.3 24.0 24.0)A
2025-10-31T13:27:47.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T13:28:09.820Z:USER:taskMaster.c:6599:Socket #1: L1N=233.1V L2N=234.2V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T13:33:21.937Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.0 24.0 24.0)A
2025-10-31T13:34:41.878Z:USER:taskMaster.c:6497:Temperature: 25.9 C
2025-10-31T13:42:47.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T13:43:09.726Z:USER:taskMaster.c:6599:Socket #1: L1N=233.7V L2N=233.1V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T13:43:21.875Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(25.8 24.0 24.0)A
2025-10-31T13:49:42.335Z:USER:taskMaster.c:6497:Temperature: 25.8 C
2025-10-31T13:53:21.812Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(23.0 24.0 24.0)A ALB:(23.9 24.0 24.0)A
2025-10-31T13:57:47.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T13:58:09.628Z:USER:taskMaster.c:6599:Socket #1: L1N=233.8V L2N=234.5V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T14:03:21.746Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(24.2 24.0 23.2)A
2025-10-31T14:04:42.738Z:USER:taskMaster.c:6497:Temperature: 26.0 C
2025-10-31T14:12:47.039Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T14:13:09.535Z:USER:taskMaster.c:6599:Socket #1: L1N=231.9V L2N=232.0V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T14:13:21.683Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(25.7 24.0 24.0)A
2025-10-31T14:19:43.195Z:USER:taskMaster.c:6497:Temperature: 26.0 C
2025-10-31T14:23:21.621Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(26.0 24.0 24.0)A ALB:(25.7 24.0 24.0)A
2025-10-31T14:27:47.042Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T14:28:09.441Z:USER:taskMaster.c:6599:Socket #1: L1N=233.2V L2N=233.5V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T14:33:21.558Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(24.0 24.0 24.0)A ALB:(23.8 24.0 24.0)A
2025-10-31T14:34:43.550Z:USER:taskMaster.c:6497:Temperature: 25.9 C
2025-10-31T14:37:37.835Z:COM:ocpp_rpc.c:715:-> [2,"288","Heartbeat",{}]
2025-10-31T14:37:37.976Z:COM:ocpp_rpc.c:1292:<- [3,"288",{"currentTime":"2025-10-31T14:37:43.806Z"}]
2025-10-31T14:37:43.000Z:SECURITY:taskTime.c:603:Time changed
2025-10-31T14:42:47.007Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T14:43:14.355Z:USER:taskMaster.c:6599:Socket #1: L1N=231.7V L2N=231.7V L3N=230.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T14:43:17.984Z:INFO:heap_trace.c:493:free: 61664/160768 (38.4%) min: 35264 (21.9%) alloc #: 218
2025-10-31T14:43:17.996Z:INFO:heap_trace.c:495:fragm: 33.4% 4K: 13.6% free blocks: # 23 largest: 41080
2025-10-31T14:43:26.503Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.1 24.0 23.0)A
2025-10-31T14:49:49.214Z:USER:taskMaster.c:6497:Temperature: 26.0 C
2025-10-31T14:53:26.441Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.0 24.0 23.0)A
2025-10-31T14:57:47.011Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T14:58:14.261Z:USER:taskMaster.c:6599:Socket #1: L1N=234.6V L2N=234.3V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T15:03:26.375Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.3 24.0 23.0)A
2025-10-31T15:04:49.667Z:USER:taskMaster.c:6497:Temperature: 25.8 C
2025-10-31T15:12:47.015Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T15:13:14.164Z:USER:taskMaster.c:6599:Socket #1: L1N=234.3V L2N=233.9V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T15:13:26.312Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.8 24.0 23.0)A
2025-10-31T15:19:50.125Z:USER:taskMaster.c:6497:Temperature: 25.6 C
2025-10-31T15:23:26.250Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.0 24.0 23.0)A
2025-10-31T15:27:47.023Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T15:28:14.070Z:USER:taskMaster.c:6599:Socket #1: L1N=231.5V L2N=231.0V L3N=230.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T15:33:26.187Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(23.8 24.0 23.0)A
2025-10-31T15:34:50.679Z:USER:taskMaster.c:6497:Temperature: 25.4 C
2025-10-31T15:42:47.027Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T15:43:13.976Z:USER:taskMaster.c:6599:Socket #1: L1N=234.0V L2N=234.3V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T15:43:26.125Z:INFO:active_lb.c:308:SMt:(2.0 1.0 2.0)A Free:(23.0 24.0 23.0)A ALB:(23.1 24.0 23.0)A
2025-10-31T15:49:50.933Z:USER:taskMaster.c:6497:Temperature: 25.4 C
2025-10-31T15:53:26.058Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(24.0 24.0 23.0)A ALB:(24.0 24.0 23.0)A
2025-10-31T15:57:47.031Z:INFO:taskMaster.c:5835:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T15:58:13.878Z:USER:taskMaster.c:6599:Socket #1: L1N=232.4V L2N=232.6V L3N=231.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T15:59:15.609Z:INFO:taskMain.c:6230:Socket #1: Active current 0.0->16.0 due to current limit: Connector-MaxCurrent,
2025-10-31T15:59:15.609Z:INFO:taskMain.c:6230:Simplified-Mode3, ChargingProfile, Start
2025-10-31T15:59:15.671Z:INFO:taskMaster.c:4875:Socket #1: state main : CABLE_CONNECTED
2025-10-31T15:59:15.683Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_A
2025-10-31T15:59:15.691Z:INFO:taskMaster.c:4897:Socket #1: state led : CABLE_CONNECTED
2025-10-31T15:59:15.878Z:INFO:taskMain.c:6730:Socket #1: CPhigh 9.3 V
2025-10-31T15:59:15.886Z:INFO:taskMain.c:6735:Socket #1: CPlow 9.3 V
2025-10-31T15:59:15.894Z:INFO:taskMain.c:6740:Socket #1: PP 699 Ohm (20 A)
2025-10-31T15:59:16.691Z:INFO:taskMain.c:1426:Socket #1: main state: CABLE_CONNECTED, CP: 9.3/0.9, no tag
2025-10-31T15:59:17.671Z:INFO:taskMaster.c:4875:Socket #1: state main : EV_CONNECTED_UNAUTHORIZED
2025-10-31T15:59:17.683Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_B1
2025-10-31T15:59:18.699Z:INFO:taskMain.c:1426:Socket #1: main state: EV_CONNECTED_UNAUTHORIZED, CP: 9.3/0.9, no tag
2025-10-31T15:59:20.972Z:USER:tag.c:1620:Reader 0 Got NFC tag: 04BB29EAFD0F94
2025-10-31T15:59:20.988Z:COM:ocpp_rpc.c:715:-> [2,"302","StatusNotification",{"connectorId":0,"errorCode":"NoError","info":"
2025-10-31T15:59:20.988Z:COM:ocpp_rpc.c:715:Info: Charge card 04BB29EAFD0F94 detected","status":"Unavailable"}]
2025-10-31T15:59:21.132Z:COM:ocpp_rpc.c:1292:<- [3,"302",{}]
2025-10-31T15:59:21.171Z:USER:taskMaster.c:6846:Socket #1: has reliable metervalue
2025-10-31T15:59:21.179Z:INFO:taskMaster.c:1571:1 cables attached
2025-10-31T15:59:21.222Z:INFO:taskMaster.c:4897:Socket #1: state led : AUTHORISING
2025-10-31T15:59:21.238Z:USER:tag.c:584:Tag 04BB29EAFD0F94 is authorised by white list
2025-10-31T15:59:21.273Z:USER:taskMaster.c:6846:Socket #1: has reliable metervalue
2025-10-31T15:59:21.281Z:USER:taskMaster.c:1872:Preparing 1, with cable 1
2025-10-31T15:59:21.320Z:USER:board_ng9xx.c:5059:Socket #1: lock socket motor
2025-10-31T15:59:21.328Z:INFO:taskMaster.c:4875:Socket #1: state main : EV_CONNECTED_AUTHORIZED
2025-10-31T15:59:21.339Z:INFO:taskMaster.c:4897:Socket #1: state led : EV_CONNECTED
2025-10-31T15:59:22.328Z:INFO:taskMain.c:1424:Socket #1: main state: EV_CONNECTED_AUTHORIZED, CP: 9.3/9.3, tag: 04BB29EAFD0F94
2025-10-31T15:59:22.417Z:INFO:taskMain.c:943:Socket #1: charging session status set active
2025-10-31T15:59:22.429Z:INFO:taskMaster.c:4875:Socket #1: state main : WAIT_FOR_START_METERVALUE
2025-10-31T15:59:22.441Z:INFO:taskMaster.c:4897:Socket #1: state led : CHARGING_PREPARING
2025-10-31T15:59:22.453Z:COM:ocpp_rpc.c:715:-> [2,"303","StatusNotification",{"connectorId":0,"errorCode":"NoError","status"
2025-10-31T15:59:22.453Z:COM:ocpp_rpc.c:715::"Available"}]
2025-10-31T15:59:22.511Z:COM:ocpp_rpc.c:1292:<- [3,"303",{}]
2025-10-31T15:59:23.531Z:INFO:taskMain.c:1424:Socket #1: main state: WAIT_FOR_START_METERVALUE, CP: 9.3/9.3, tag: 04BB29EAFD0F
2025-10-31T15:59:23.531Z:INFO:taskMain.c:1424:94
2025-10-31T15:59:25.472Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_PRE_POWER_OFF
2025-10-31T15:59:25.574Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_POWER_OFF
2025-10-31T15:59:25.582Z:INFO:taskMaster.c:4897:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-10-31T15:59:25.621Z:INFO:taskMaster.c:4875:Socket #1: state main : CHARGING_TERMINATING
2025-10-31T15:59:25.722Z:INFO:taskMaster.c:4897:Socket #1: state led : WAIT_FOR_VEHICLE
2025-10-31T15:59:26.800Z:INFO:taskMain.c:1424:Socket #1: main state: CHARGING_TERMINATING, CP: 9.3/9.3, tag: 04BB29EAFD0F94
2025-10-31T15:59:29.722Z:INFO:taskMaster.c:4875:Socket #1: state main : WAIT_FOR_STOP_METERVALUE
2025-10-31T15:59:29.867Z:INFO:taskMain.c:943:Socket #1: charging session status set inactive
2025-10-31T15:59:29.878Z:INFO:taskMaster.c:4875:Socket #1: state main : WAIT_FOR_DISCONNECT
2025-10-31T15:59:29.886Z:USER:board_ng9xx.c:5059:Socket #1: unlock socket motor
2025-10-31T15:59:29.941Z:INFO:db_transaction.c:16:Updated TransactionStop for socket 1 at 0x00000482 (ts: 2025-10-31 15:59:29)
2025-10-31T15:59:29.976Z:COM:ocpp_rpc.c:715:-> [2,"304","MeterValues",{"connectorId":1,"transactionId":1,"meterValue":[{"tim
2025-10-31T15:59:29.976Z:COM:ocpp_rpc.c:715:estamp":"2025-10-31T15:59:29Z","sampledValue":[{"value":"5540.316","context":"Tr
2025-10-31T15:59:29.976Z:COM:ocpp_rpc.c:715:ansaction.End","unit":"kWh"}]}]}]
2025-10-31T15:59:30.011Z:INFO:taskMaster.c:4897:Socket #1: state led : WAIT_FOR_DISCONNECT
2025-10-31T15:59:30.898Z:INFO:taskMain.c:1424:Socket #1: main state: WAIT_FOR_DISCONNECT, CP: 9.3/9.3, tag: 04BB29EAFD0F94
2025-10-31T15:59:31.101Z:COM:ocpp_rpc.c:1292:<- [3,"304",{}]
2025-10-31T15:59:31.109Z:COM:ocpp_rpc.c:715:-> [2,"305","StatusNotification",{"connectorId":1,"errorCode":"NoError","status"
2025-10-31T15:59:31.109Z:COM:ocpp_rpc.c:715::"Finishing"}]
2025-10-31T15:59:31.210Z:COM:ocpp_rpc.c:1292:<- [3,"305",{}]
2025-10-31T15:59:31.218Z:COM:ocpp_rpc.c:715:-> [2,"306","StatusNotification",{"connectorId":0,"errorCode":"NoError","status"
2025-10-31T15:59:31.218Z:COM:ocpp_rpc.c:715::"Unavailable"}]
2025-10-31T15:59:31.273Z:COM:ocpp_rpc.c:1292:<- [3,"306",{}]
2025-10-31T15:59:31.281Z:COM:ocpp_rpc.c:715:-> [2,"307","StopTransaction",{"timestamp":"2025-10-31T15:59:29Z","transactionId
2025-10-31T15:59:31.281Z:COM:ocpp_rpc.c:715:":1,"meterStop":5540316,"idTag":"04BB29EAFD0F94","reason":"Other","transactionDa
2025-10-31T15:59:31.281Z:COM:ocpp_rpc.c:715:ta":[{"timestamp":"2025-10-28T18:27:42Z","sampledValue":[{"value":"5518.267","co
2025-10-31T15:59:31.281Z:COM:ocpp_rpc.c:715:ntext":"Transaction.Begin","unit":"kWh"}]},{"timestamp":"2025-10-31T15:59:29Z","
2025-10-31T15:59:31.281Z:COM:ocpp_rpc.c:715:sampledValue":[{"value":"5540.316","context":"Transaction.End","unit":"kWh"}]}]}
2025-10-31T15:59:31.281Z:COM:ocpp_rpc.c:715:]
2025-10-31T15:59:31.769Z:COM:ocpp_rpc.c:1292:<- [3,"307",{"idTagInfo":{"status":"Accepted","expiryDate":"2030-12-31T00:00:00.
2025-10-31T15:59:31.769Z:COM:ocpp_rpc.c:1292:000Z"}}]
2025-10-31T15:59:31.789Z:INFO:db_transaction.c:16:Updated TransactionStop for socket 1 at 0x00000482 (ts: 2025-10-31 15:59:29)
2025-10-31T15:59:31.816Z:USER:tag.c:1827:Tag 04BB29EAFD0F94 is authorised by server, white list updated
2025-10-31T15:59:31.902Z:COM:ocpp_rpc.c:715:-> [2,"308","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:31.902Z:COM:ocpp_rpc.c:715:9T06:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:31.902Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:31.960Z:COM:ocpp_rpc.c:1292:<- [3,"308",{}]
2025-10-31T15:59:32.042Z:COM:ocpp_rpc.c:715:-> [2,"309","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:32.042Z:COM:ocpp_rpc.c:715:9T06:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:32.042Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:32.101Z:COM:ocpp_rpc.c:1292:<- [3,"309",{}]
2025-10-31T15:59:32.203Z:COM:ocpp_rpc.c:715:-> [2,"310","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:32.203Z:COM:ocpp_rpc.c:715:9T06:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:32.203Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:32.269Z:COM:ocpp_rpc.c:1292:<- [3,"310",{}]
2025-10-31T15:59:32.355Z:COM:ocpp_rpc.c:715:-> [2,"311","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:32.355Z:COM:ocpp_rpc.c:715:9T07:12:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:32.355Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:32.421Z:COM:ocpp_rpc.c:1292:<- [3,"311",{}]
2025-10-31T15:59:32.507Z:COM:ocpp_rpc.c:715:-> [2,"312","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:32.507Z:COM:ocpp_rpc.c:715:9T07:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:32.507Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:32.558Z:COM:ocpp_rpc.c:1292:<- [3,"312",{}]
2025-10-31T15:59:32.644Z:COM:ocpp_rpc.c:715:-> [2,"313","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:32.644Z:COM:ocpp_rpc.c:715:9T07:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:32.644Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:32.703Z:COM:ocpp_rpc.c:1292:<- [3,"313",{}]
2025-10-31T15:59:32.785Z:COM:ocpp_rpc.c:715:-> [2,"314","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:32.785Z:COM:ocpp_rpc.c:715:9T07:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:32.785Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:32.839Z:COM:ocpp_rpc.c:1292:<- [3,"314",{}]
2025-10-31T15:59:32.921Z:COM:ocpp_rpc.c:715:-> [2,"315","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:32.921Z:COM:ocpp_rpc.c:715:9T08:12:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:32.921Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:32.992Z:COM:ocpp_rpc.c:1292:<- [3,"315",{}]
2025-10-31T15:59:33.074Z:COM:ocpp_rpc.c:715:-> [2,"316","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:33.074Z:COM:ocpp_rpc.c:715:9T08:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:33.074Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:33.132Z:COM:ocpp_rpc.c:1292:<- [3,"316",{}]
2025-10-31T15:59:33.214Z:COM:ocpp_rpc.c:715:-> [2,"317","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:33.214Z:COM:ocpp_rpc.c:715:9T08:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:33.214Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:33.277Z:COM:ocpp_rpc.c:1292:<- [3,"317",{}]
2025-10-31T15:59:33.363Z:COM:ocpp_rpc.c:715:-> [2,"318","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:33.363Z:COM:ocpp_rpc.c:715:9T08:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:33.363Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:33.449Z:COM:ocpp_rpc.c:1292:<- [3,"318",{}]
2025-10-31T15:59:33.535Z:COM:ocpp_rpc.c:715:-> [2,"319","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:33.535Z:COM:ocpp_rpc.c:715:9T09:12:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:33.535Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:33.582Z:COM:ocpp_rpc.c:1292:<- [3,"319",{}]
2025-10-31T15:59:33.667Z:COM:ocpp_rpc.c:715:-> [2,"320","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:33.667Z:COM:ocpp_rpc.c:715:9T09:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:33.667Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:33.718Z:COM:ocpp_rpc.c:1292:<- [3,"320",{}]
2025-10-31T15:59:33.800Z:COM:ocpp_rpc.c:715:-> [2,"321","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:33.800Z:COM:ocpp_rpc.c:715:9T09:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:33.800Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:33.859Z:COM:ocpp_rpc.c:1292:<- [3,"321",{}]
2025-10-31T15:59:33.949Z:COM:ocpp_rpc.c:715:-> [2,"322","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:33.949Z:COM:ocpp_rpc.c:715:9T09:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:33.949Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:34.000Z:COM:ocpp_rpc.c:1292:<- [3,"322",{}]
2025-10-31T15:59:34.082Z:COM:ocpp_rpc.c:715:-> [2,"323","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:34.082Z:COM:ocpp_rpc.c:715:9T10:12:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:34.082Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:34.140Z:COM:ocpp_rpc.c:1292:<- [3,"323",{}]
2025-10-31T15:59:34.222Z:COM:ocpp_rpc.c:715:-> [2,"324","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:34.222Z:COM:ocpp_rpc.c:715:9T10:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:34.222Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:34.281Z:COM:ocpp_rpc.c:1292:<- [3,"324",{}]
2025-10-31T15:59:34.367Z:COM:ocpp_rpc.c:715:-> [2,"325","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:34.367Z:COM:ocpp_rpc.c:715:9T10:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:34.367Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:34.410Z:COM:ocpp_rpc.c:1292:<- [3,"325",{}]
2025-10-31T15:59:34.515Z:COM:ocpp_rpc.c:715:-> [2,"326","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:34.515Z:COM:ocpp_rpc.c:715:9T10:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:34.515Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:34.562Z:COM:ocpp_rpc.c:1292:<- [3,"326",{}]
2025-10-31T15:59:34.644Z:COM:ocpp_rpc.c:715:-> [2,"327","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:34.644Z:COM:ocpp_rpc.c:715:9T11:12:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:34.644Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:34.699Z:COM:ocpp_rpc.c:1292:<- [3,"327",{}]
2025-10-31T15:59:34.785Z:COM:ocpp_rpc.c:715:-> [2,"328","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:34.785Z:COM:ocpp_rpc.c:715:9T11:27:44Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:34.785Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:34.832Z:COM:ocpp_rpc.c:1292:<- [3,"328",{}]
2025-10-31T15:59:34.914Z:COM:ocpp_rpc.c:715:-> [2,"329","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:34.914Z:COM:ocpp_rpc.c:715:9T11:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:34.914Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:34.972Z:COM:ocpp_rpc.c:1292:<- [3,"329",{}]
2025-10-31T15:59:35.054Z:COM:ocpp_rpc.c:715:-> [2,"330","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:35.054Z:COM:ocpp_rpc.c:715:9T11:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:35.054Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:35.121Z:COM:ocpp_rpc.c:1292:<- [3,"330",{}]
2025-10-31T15:59:35.207Z:COM:ocpp_rpc.c:715:-> [2,"331","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:35.207Z:COM:ocpp_rpc.c:715:9T12:12:44Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:35.207Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:35.257Z:COM:ocpp_rpc.c:1292:<- [3,"331",{}]
2025-10-31T15:59:35.343Z:COM:ocpp_rpc.c:715:-> [2,"332","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:35.343Z:COM:ocpp_rpc.c:715:9T12:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:35.343Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:35.417Z:COM:ocpp_rpc.c:1292:<- [3,"332",{}]
2025-10-31T15:59:35.503Z:COM:ocpp_rpc.c:715:-> [2,"333","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:35.503Z:COM:ocpp_rpc.c:715:9T12:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:35.503Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:35.562Z:COM:ocpp_rpc.c:1292:<- [3,"333",{}]
2025-10-31T15:59:35.644Z:COM:ocpp_rpc.c:715:-> [2,"334","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:35.644Z:COM:ocpp_rpc.c:715:9T12:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:35.644Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:35.707Z:COM:ocpp_rpc.c:1292:<- [3,"334",{}]
2025-10-31T15:59:35.792Z:COM:ocpp_rpc.c:715:-> [2,"335","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:35.792Z:COM:ocpp_rpc.c:715:9T13:12:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:35.792Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:35.871Z:COM:ocpp_rpc.c:1292:<- [3,"335",{}]
2025-10-31T15:59:35.957Z:COM:ocpp_rpc.c:715:-> [2,"336","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:35.957Z:COM:ocpp_rpc.c:715:9T13:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:35.957Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:36.007Z:COM:ocpp_rpc.c:1292:<- [3,"336",{}]
2025-10-31T15:59:36.093Z:COM:ocpp_rpc.c:715:-> [2,"337","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:36.093Z:COM:ocpp_rpc.c:715:9T13:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:36.093Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:36.148Z:COM:ocpp_rpc.c:1292:<- [3,"337",{}]
2025-10-31T15:59:36.234Z:COM:ocpp_rpc.c:715:-> [2,"338","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:36.234Z:COM:ocpp_rpc.c:715:9T13:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:36.234Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:36.289Z:COM:ocpp_rpc.c:1292:<- [3,"338",{}]
2025-10-31T15:59:36.371Z:COM:ocpp_rpc.c:715:-> [2,"339","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:36.371Z:COM:ocpp_rpc.c:715:9T14:12:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:36.371Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:36.429Z:COM:ocpp_rpc.c:1292:<- [3,"339",{}]
2025-10-31T15:59:36.515Z:COM:ocpp_rpc.c:715:-> [2,"340","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:36.515Z:COM:ocpp_rpc.c:715:9T14:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:36.515Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:36.562Z:COM:ocpp_rpc.c:1292:<- [3,"340",{}]
2025-10-31T15:59:36.644Z:COM:ocpp_rpc.c:715:-> [2,"341","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:36.644Z:COM:ocpp_rpc.c:715:9T14:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:36.644Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:36.703Z:COM:ocpp_rpc.c:1292:<- [3,"341",{}]
2025-10-31T15:59:36.804Z:COM:ocpp_rpc.c:715:-> [2,"342","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:36.804Z:COM:ocpp_rpc.c:715:9T14:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:36.804Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:36.859Z:COM:ocpp_rpc.c:1292:<- [3,"342",{}]
2025-10-31T15:59:36.945Z:COM:ocpp_rpc.c:715:-> [2,"343","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:36.945Z:COM:ocpp_rpc.c:715:9T15:12:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:36.945Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:37.000Z:COM:ocpp_rpc.c:1292:<- [3,"343",{}]
2025-10-31T15:59:37.082Z:COM:ocpp_rpc.c:715:-> [2,"344","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:37.082Z:COM:ocpp_rpc.c:715:9T15:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:37.082Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:37.140Z:COM:ocpp_rpc.c:1292:<- [3,"344",{}]
2025-10-31T15:59:37.222Z:COM:ocpp_rpc.c:715:-> [2,"345","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:37.222Z:COM:ocpp_rpc.c:715:9T15:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:37.222Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:37.281Z:COM:ocpp_rpc.c:1292:<- [3,"345",{}]
2025-10-31T15:59:37.367Z:COM:ocpp_rpc.c:715:-> [2,"346","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:37.367Z:COM:ocpp_rpc.c:715:9T15:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:37.367Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:37.417Z:COM:ocpp_rpc.c:1292:<- [3,"346",{}]
2025-10-31T15:59:37.503Z:COM:ocpp_rpc.c:715:-> [2,"347","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:37.503Z:COM:ocpp_rpc.c:715:9T16:12:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:37.503Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:37.562Z:COM:ocpp_rpc.c:1292:<- [3,"347",{}]
2025-10-31T15:59:37.644Z:COM:ocpp_rpc.c:715:-> [2,"348","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:37.644Z:COM:ocpp_rpc.c:715:9T16:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:37.644Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:37.691Z:COM:ocpp_rpc.c:1292:<- [3,"348",{}]
2025-10-31T15:59:37.777Z:COM:ocpp_rpc.c:715:-> [2,"349","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:37.777Z:COM:ocpp_rpc.c:715:9T16:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:37.777Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:37.832Z:COM:ocpp_rpc.c:1292:<- [3,"349",{}]
2025-10-31T15:59:37.914Z:COM:ocpp_rpc.c:715:-> [2,"350","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:37.914Z:COM:ocpp_rpc.c:715:9T16:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:37.914Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:37.972Z:COM:ocpp_rpc.c:1292:<- [3,"350",{}]
2025-10-31T15:59:38.054Z:COM:ocpp_rpc.c:715:-> [2,"351","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:38.054Z:COM:ocpp_rpc.c:715:9T17:12:44Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:38.054Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:38.101Z:COM:ocpp_rpc.c:1292:<- [3,"351",{}]
2025-10-31T15:59:38.187Z:COM:ocpp_rpc.c:715:-> [2,"352","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:38.187Z:COM:ocpp_rpc.c:715:9T17:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:38.187Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:38.226Z:COM:ocpp_rpc.c:1292:<- [3,"352",{}]
2025-10-31T15:59:38.312Z:COM:ocpp_rpc.c:715:-> [2,"353","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:38.312Z:COM:ocpp_rpc.c:715:9T17:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:38.312Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:38.367Z:COM:ocpp_rpc.c:1292:<- [3,"353",{}]
2025-10-31T15:59:38.453Z:COM:ocpp_rpc.c:715:-> [2,"354","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:38.453Z:COM:ocpp_rpc.c:715:9T17:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:38.453Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:38.511Z:COM:ocpp_rpc.c:1292:<- [3,"354",{}]
2025-10-31T15:59:38.593Z:COM:ocpp_rpc.c:715:-> [2,"355","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:38.593Z:COM:ocpp_rpc.c:715:9T18:12:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:38.593Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:38.652Z:COM:ocpp_rpc.c:1292:<- [3,"355",{}]
2025-10-31T15:59:38.738Z:COM:ocpp_rpc.c:715:-> [2,"356","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:38.738Z:COM:ocpp_rpc.c:715:9T18:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:38.738Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:38.789Z:COM:ocpp_rpc.c:1292:<- [3,"356",{}]
2025-10-31T15:59:38.875Z:COM:ocpp_rpc.c:715:-> [2,"357","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:38.875Z:COM:ocpp_rpc.c:715:9T18:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:38.875Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:38.933Z:COM:ocpp_rpc.c:1292:<- [3,"357",{}]
2025-10-31T15:59:39.039Z:COM:ocpp_rpc.c:715:-> [2,"358","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:39.039Z:COM:ocpp_rpc.c:715:9T18:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:39.039Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:39.101Z:COM:ocpp_rpc.c:1292:<- [3,"358",{}]
2025-10-31T15:59:39.183Z:COM:ocpp_rpc.c:715:-> [2,"359","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:39.183Z:COM:ocpp_rpc.c:715:9T19:12:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:39.183Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:39.230Z:COM:ocpp_rpc.c:1292:<- [3,"359",{}]
2025-10-31T15:59:39.316Z:COM:ocpp_rpc.c:715:-> [2,"360","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:39.316Z:COM:ocpp_rpc.c:715:9T19:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:39.316Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:39.359Z:COM:ocpp_rpc.c:1292:<- [3,"360",{}]
2025-10-31T15:59:39.441Z:COM:ocpp_rpc.c:715:-> [2,"361","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:39.441Z:COM:ocpp_rpc.c:715:9T19:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:39.441Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:39.500Z:COM:ocpp_rpc.c:1292:<- [3,"361",{}]
2025-10-31T15:59:39.585Z:COM:ocpp_rpc.c:715:-> [2,"362","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:39.585Z:COM:ocpp_rpc.c:715:9T19:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:39.585Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:39.636Z:COM:ocpp_rpc.c:1292:<- [3,"362",{}]
2025-10-31T15:59:39.722Z:COM:ocpp_rpc.c:715:-> [2,"363","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:39.722Z:COM:ocpp_rpc.c:715:9T20:12:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:39.722Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:39.769Z:COM:ocpp_rpc.c:1292:<- [3,"363",{}]
2025-10-31T15:59:39.855Z:COM:ocpp_rpc.c:715:-> [2,"364","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:39.855Z:COM:ocpp_rpc.c:715:9T20:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:39.855Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:39.902Z:COM:ocpp_rpc.c:1292:<- [3,"364",{}]
2025-10-31T15:59:39.992Z:COM:ocpp_rpc.c:715:-> [2,"365","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:39.992Z:COM:ocpp_rpc.c:715:9T20:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:39.992Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:40.039Z:COM:ocpp_rpc.c:1292:<- [3,"365",{}]
2025-10-31T15:59:40.125Z:COM:ocpp_rpc.c:715:-> [2,"366","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:40.125Z:COM:ocpp_rpc.c:715:9T20:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:40.125Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:40.191Z:COM:ocpp_rpc.c:1292:<- [3,"366",{}]
2025-10-31T15:59:40.277Z:COM:ocpp_rpc.c:715:-> [2,"367","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:40.277Z:COM:ocpp_rpc.c:715:9T21:12:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:40.277Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:40.328Z:COM:ocpp_rpc.c:1292:<- [3,"367",{}]
2025-10-31T15:59:40.410Z:COM:ocpp_rpc.c:715:-> [2,"368","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:40.410Z:COM:ocpp_rpc.c:715:9T21:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:40.410Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:40.457Z:COM:ocpp_rpc.c:1292:<- [3,"368",{}]
2025-10-31T15:59:40.546Z:COM:ocpp_rpc.c:715:-> [2,"369","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:40.546Z:COM:ocpp_rpc.c:715:9T21:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:40.546Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:40.589Z:COM:ocpp_rpc.c:1292:<- [3,"369",{}]
2025-10-31T15:59:40.671Z:COM:ocpp_rpc.c:715:-> [2,"370","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:40.671Z:COM:ocpp_rpc.c:715:9T21:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:40.671Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:40.718Z:COM:ocpp_rpc.c:1292:<- [3,"370",{}]
2025-10-31T15:59:40.804Z:COM:ocpp_rpc.c:715:-> [2,"371","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:40.804Z:COM:ocpp_rpc.c:715:9T22:12:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:40.804Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:40.859Z:COM:ocpp_rpc.c:1292:<- [3,"371",{}]
2025-10-31T15:59:40.945Z:COM:ocpp_rpc.c:715:-> [2,"372","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:40.945Z:COM:ocpp_rpc.c:715:9T22:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:40.945Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:41.000Z:COM:ocpp_rpc.c:1292:<- [3,"372",{}]
2025-10-31T15:59:41.085Z:COM:ocpp_rpc.c:715:-> [2,"373","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:41.085Z:COM:ocpp_rpc.c:715:9T22:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:41.085Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:41.140Z:COM:ocpp_rpc.c:1292:<- [3,"373",{}]
2025-10-31T15:59:41.242Z:COM:ocpp_rpc.c:715:-> [2,"374","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:41.242Z:COM:ocpp_rpc.c:715:9T22:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:41.242Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:41.289Z:COM:ocpp_rpc.c:1292:<- [3,"374",{}]
2025-10-31T15:59:41.375Z:COM:ocpp_rpc.c:715:-> [2,"375","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:41.375Z:COM:ocpp_rpc.c:715:9T23:12:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:41.375Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:41.417Z:COM:ocpp_rpc.c:1292:<- [3,"375",{}]
2025-10-31T15:59:41.503Z:COM:ocpp_rpc.c:715:-> [2,"376","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:41.503Z:COM:ocpp_rpc.c:715:9T23:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:41.503Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:41.562Z:COM:ocpp_rpc.c:1292:<- [3,"376",{}]
2025-10-31T15:59:41.644Z:COM:ocpp_rpc.c:715:-> [2,"377","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:41.644Z:COM:ocpp_rpc.c:715:9T23:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:41.644Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:41.699Z:COM:ocpp_rpc.c:1292:<- [3,"377",{}]
2025-10-31T15:59:41.785Z:COM:ocpp_rpc.c:715:-> [2,"378","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-2
2025-10-31T15:59:41.785Z:COM:ocpp_rpc.c:715:9T23:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:41.785Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:41.839Z:COM:ocpp_rpc.c:1292:<- [3,"378",{}]
2025-10-31T15:59:41.925Z:COM:ocpp_rpc.c:715:-> [2,"379","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:41.925Z:COM:ocpp_rpc.c:715:0T00:12:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:41.925Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:41.968Z:COM:ocpp_rpc.c:1292:<- [3,"379",{}]
2025-10-31T15:59:42.050Z:COM:ocpp_rpc.c:715:-> [2,"380","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:42.050Z:COM:ocpp_rpc.c:715:0T00:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:42.050Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:42.101Z:COM:ocpp_rpc.c:1292:<- [3,"380",{}]
2025-10-31T15:59:42.183Z:COM:ocpp_rpc.c:715:-> [2,"381","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:42.183Z:COM:ocpp_rpc.c:715:0T00:42:44Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:42.183Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:42.230Z:COM:ocpp_rpc.c:1292:<- [3,"381",{}]
2025-10-31T15:59:42.312Z:COM:ocpp_rpc.c:715:-> [2,"382","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:42.312Z:COM:ocpp_rpc.c:715:0T00:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:42.312Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:42.359Z:COM:ocpp_rpc.c:1292:<- [3,"382",{}]
2025-10-31T15:59:42.445Z:COM:ocpp_rpc.c:715:-> [2,"383","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:42.445Z:COM:ocpp_rpc.c:715:0T01:12:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:42.445Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:42.492Z:COM:ocpp_rpc.c:1292:<- [3,"383",{}]
2025-10-31T15:59:42.578Z:COM:ocpp_rpc.c:715:-> [2,"384","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:42.578Z:COM:ocpp_rpc.c:715:0T01:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:42.578Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:42.628Z:COM:ocpp_rpc.c:1292:<- [3,"384",{}]
2025-10-31T15:59:42.714Z:COM:ocpp_rpc.c:715:-> [2,"385","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:42.714Z:COM:ocpp_rpc.c:715:0T01:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:42.714Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:42.761Z:COM:ocpp_rpc.c:1292:<- [3,"385",{}]
2025-10-31T15:59:42.843Z:COM:ocpp_rpc.c:715:-> [2,"386","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:42.843Z:COM:ocpp_rpc.c:715:0T01:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:42.843Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:42.886Z:COM:ocpp_rpc.c:1292:<- [3,"386",{}]
2025-10-31T15:59:42.972Z:COM:ocpp_rpc.c:715:-> [2,"387","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:42.972Z:COM:ocpp_rpc.c:715:0T02:12:44Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:42.972Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:43.019Z:COM:ocpp_rpc.c:1292:<- [3,"387",{}]
2025-10-31T15:59:43.101Z:COM:ocpp_rpc.c:715:-> [2,"388","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:43.101Z:COM:ocpp_rpc.c:715:0T02:27:44Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:43.101Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:43.160Z:COM:ocpp_rpc.c:1292:<- [3,"388",{}]
2025-10-31T15:59:43.246Z:COM:ocpp_rpc.c:715:-> [2,"389","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:43.246Z:COM:ocpp_rpc.c:715:0T02:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:43.246Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:43.289Z:COM:ocpp_rpc.c:1292:<- [3,"389",{}]
2025-10-31T15:59:43.390Z:COM:ocpp_rpc.c:715:-> [2,"390","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:43.390Z:COM:ocpp_rpc.c:715:0T02:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:43.390Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:43.437Z:COM:ocpp_rpc.c:1292:<- [3,"390",{}]
2025-10-31T15:59:43.523Z:COM:ocpp_rpc.c:715:-> [2,"391","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:43.523Z:COM:ocpp_rpc.c:715:0T03:12:44Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:43.523Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:43.570Z:COM:ocpp_rpc.c:1292:<- [3,"391",{}]
2025-10-31T15:59:43.656Z:COM:ocpp_rpc.c:715:-> [2,"392","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:43.656Z:COM:ocpp_rpc.c:715:0T03:27:44Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:43.656Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:43.699Z:COM:ocpp_rpc.c:1292:<- [3,"392",{}]
2025-10-31T15:59:43.781Z:COM:ocpp_rpc.c:715:-> [2,"393","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:43.781Z:COM:ocpp_rpc.c:715:0T03:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:43.781Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:43.828Z:COM:ocpp_rpc.c:1292:<- [3,"393",{}]
2025-10-31T15:59:43.914Z:COM:ocpp_rpc.c:715:-> [2,"394","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:43.914Z:COM:ocpp_rpc.c:715:0T03:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:43.914Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:43.960Z:COM:ocpp_rpc.c:1292:<- [3,"394",{}]
2025-10-31T15:59:44.050Z:COM:ocpp_rpc.c:715:-> [2,"395","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:44.050Z:COM:ocpp_rpc.c:715:0T04:12:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:44.050Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:44.113Z:COM:ocpp_rpc.c:1292:<- [3,"395",{}]
2025-10-31T15:59:44.195Z:COM:ocpp_rpc.c:715:-> [2,"396","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:44.195Z:COM:ocpp_rpc.c:715:0T04:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:44.195Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:44.238Z:COM:ocpp_rpc.c:1292:<- [3,"396",{}]
2025-10-31T15:59:44.320Z:COM:ocpp_rpc.c:715:-> [2,"397","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:44.320Z:COM:ocpp_rpc.c:715:0T04:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:44.320Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:44.378Z:COM:ocpp_rpc.c:1292:<- [3,"397",{}]
2025-10-31T15:59:44.460Z:COM:ocpp_rpc.c:715:-> [2,"398","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:44.460Z:COM:ocpp_rpc.c:715:0T04:57:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:44.460Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:44.519Z:COM:ocpp_rpc.c:1292:<- [3,"398",{}]
2025-10-31T15:59:44.605Z:COM:ocpp_rpc.c:715:-> [2,"399","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:44.605Z:COM:ocpp_rpc.c:715:0T05:12:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:44.605Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:44.660Z:COM:ocpp_rpc.c:1292:<- [3,"399",{}]
2025-10-31T15:59:44.742Z:COM:ocpp_rpc.c:715:-> [2,"400","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:44.742Z:COM:ocpp_rpc.c:715:0T05:27:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:44.742Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:44.812Z:COM:ocpp_rpc.c:1292:<- [3,"400",{}]
2025-10-31T15:59:44.894Z:COM:ocpp_rpc.c:715:-> [2,"401","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:44.894Z:COM:ocpp_rpc.c:715:0T05:42:43Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:44.894Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:44.949Z:COM:ocpp_rpc.c:1292:<- [3,"401",{}]
2025-10-31T15:59:44.968Z:USER:tag.c:1620:Reader 0 Got NFC tag: 04BB29EAFD0F94
2025-10-31T15:59:45.031Z:COM:ocpp_rpc.c:715:-> [2,"402","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:45.031Z:COM:ocpp_rpc.c:715:0T05:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:45.031Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:45.089Z:COM:ocpp_rpc.c:1292:<- [3,"402",{}]
2025-10-31T15:59:45.175Z:COM:ocpp_rpc.c:715:-> [2,"403","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:45.175Z:COM:ocpp_rpc.c:715:0T06:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:45.175Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:45.218Z:COM:ocpp_rpc.c:1292:<- [3,"403",{}]
2025-10-31T15:59:45.304Z:COM:ocpp_rpc.c:715:-> [2,"404","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:45.304Z:COM:ocpp_rpc.c:715:0T06:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:45.304Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:45.363Z:COM:ocpp_rpc.c:1292:<- [3,"404",{}]
2025-10-31T15:59:45.445Z:COM:ocpp_rpc.c:715:-> [2,"405","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:45.445Z:COM:ocpp_rpc.c:715:0T06:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:45.445Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:45.488Z:COM:ocpp_rpc.c:1292:<- [3,"405",{}]
2025-10-31T15:59:45.570Z:COM:ocpp_rpc.c:715:-> [2,"406","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:45.570Z:COM:ocpp_rpc.c:715:0T06:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:45.570Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:45.617Z:COM:ocpp_rpc.c:1292:<- [3,"406",{}]
2025-10-31T15:59:45.703Z:COM:ocpp_rpc.c:715:-> [2,"407","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:45.703Z:COM:ocpp_rpc.c:715:0T07:12:48Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:45.703Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:45.750Z:COM:ocpp_rpc.c:1292:<- [3,"407",{}]
2025-10-31T15:59:45.839Z:COM:ocpp_rpc.c:715:-> [2,"408","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:45.839Z:COM:ocpp_rpc.c:715:0T07:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:45.839Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:45.886Z:COM:ocpp_rpc.c:1292:<- [3,"408",{}]
2025-10-31T15:59:45.972Z:COM:ocpp_rpc.c:715:-> [2,"409","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:45.972Z:COM:ocpp_rpc.c:715:0T07:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:45.972Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:46.027Z:COM:ocpp_rpc.c:1292:<- [3,"409",{}]
2025-10-31T15:59:46.113Z:COM:ocpp_rpc.c:715:-> [2,"410","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:46.113Z:COM:ocpp_rpc.c:715:0T07:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:46.113Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:46.171Z:COM:ocpp_rpc.c:1292:<- [3,"410",{}]
2025-10-31T15:59:46.253Z:COM:ocpp_rpc.c:715:-> [2,"411","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:46.253Z:COM:ocpp_rpc.c:715:0T08:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:46.253Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:46.308Z:COM:ocpp_rpc.c:1292:<- [3,"411",{}]
2025-10-31T15:59:46.390Z:COM:ocpp_rpc.c:715:-> [2,"412","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:46.390Z:COM:ocpp_rpc.c:715:0T08:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:46.390Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:46.460Z:COM:ocpp_rpc.c:1292:<- [3,"412",{}]
2025-10-31T15:59:46.542Z:COM:ocpp_rpc.c:715:-> [2,"413","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:46.542Z:COM:ocpp_rpc.c:715:0T08:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:46.542Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:46.601Z:COM:ocpp_rpc.c:1292:<- [3,"413",{}]
2025-10-31T15:59:46.683Z:COM:ocpp_rpc.c:715:-> [2,"414","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:46.683Z:COM:ocpp_rpc.c:715:0T08:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:46.683Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:46.738Z:COM:ocpp_rpc.c:1292:<- [3,"414",{}]
2025-10-31T15:59:46.820Z:COM:ocpp_rpc.c:715:-> [2,"415","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:46.820Z:COM:ocpp_rpc.c:715:0T09:12:48Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:46.820Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:46.878Z:COM:ocpp_rpc.c:1292:<- [3,"415",{}]
2025-10-31T15:59:46.964Z:COM:ocpp_rpc.c:715:-> [2,"416","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:46.964Z:COM:ocpp_rpc.c:715:0T09:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:46.964Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:47.031Z:COM:ocpp_rpc.c:1292:<- [3,"416",{}]
2025-10-31T15:59:47.113Z:COM:ocpp_rpc.c:715:-> [2,"417","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:47.113Z:COM:ocpp_rpc.c:715:0T09:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:47.113Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:47.167Z:COM:ocpp_rpc.c:1292:<- [3,"417",{}]
2025-10-31T15:59:47.250Z:COM:ocpp_rpc.c:715:-> [2,"418","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:47.250Z:COM:ocpp_rpc.c:715:0T09:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:47.250Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:47.308Z:COM:ocpp_rpc.c:1292:<- [3,"418",{}]
2025-10-31T15:59:47.390Z:COM:ocpp_rpc.c:715:-> [2,"419","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:47.390Z:COM:ocpp_rpc.c:715:0T10:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:47.390Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:47.437Z:COM:ocpp_rpc.c:1292:<- [3,"419",{}]
2025-10-31T15:59:47.523Z:COM:ocpp_rpc.c:715:-> [2,"420","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:47.523Z:COM:ocpp_rpc.c:715:0T10:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:47.523Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:47.570Z:COM:ocpp_rpc.c:1292:<- [3,"420",{}]
2025-10-31T15:59:47.656Z:COM:ocpp_rpc.c:715:-> [2,"421","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:47.656Z:COM:ocpp_rpc.c:715:0T10:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:47.656Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:47.699Z:COM:ocpp_rpc.c:1292:<- [3,"421",{}]
2025-10-31T15:59:47.785Z:COM:ocpp_rpc.c:715:-> [2,"422","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:47.785Z:COM:ocpp_rpc.c:715:0T10:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:47.785Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:47.828Z:COM:ocpp_rpc.c:1292:<- [3,"422",{}]
2025-10-31T15:59:47.910Z:COM:ocpp_rpc.c:715:-> [2,"423","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:47.910Z:COM:ocpp_rpc.c:715:0T11:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:47.910Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:47.957Z:COM:ocpp_rpc.c:1292:<- [3,"423",{}]
2025-10-31T15:59:48.046Z:COM:ocpp_rpc.c:715:-> [2,"424","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:48.046Z:COM:ocpp_rpc.c:715:0T11:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:48.046Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:48.101Z:COM:ocpp_rpc.c:1292:<- [3,"424",{}]
2025-10-31T15:59:48.183Z:COM:ocpp_rpc.c:715:-> [2,"425","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:48.183Z:COM:ocpp_rpc.c:715:0T11:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:48.183Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:48.230Z:COM:ocpp_rpc.c:1292:<- [3,"425",{}]
2025-10-31T15:59:48.316Z:COM:ocpp_rpc.c:715:-> [2,"426","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:48.316Z:COM:ocpp_rpc.c:715:0T11:57:48Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:48.316Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:48.355Z:COM:ocpp_rpc.c:1292:<- [3,"426",{}]
2025-10-31T15:59:48.441Z:COM:ocpp_rpc.c:715:-> [2,"427","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:48.441Z:COM:ocpp_rpc.c:715:0T12:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:48.441Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:48.488Z:COM:ocpp_rpc.c:1292:<- [3,"427",{}]
2025-10-31T15:59:48.574Z:COM:ocpp_rpc.c:715:-> [2,"428","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:48.574Z:COM:ocpp_rpc.c:715:0T12:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:48.574Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:48.660Z:COM:ocpp_rpc.c:1292:<- [3,"428",{}]
2025-10-31T15:59:48.746Z:COM:ocpp_rpc.c:715:-> [2,"429","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:48.746Z:COM:ocpp_rpc.c:715:0T12:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:48.746Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:48.789Z:COM:ocpp_rpc.c:1292:<- [3,"429",{}]
2025-10-31T15:59:48.871Z:COM:ocpp_rpc.c:715:-> [2,"430","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:48.871Z:COM:ocpp_rpc.c:715:0T12:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:48.871Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:48.929Z:COM:ocpp_rpc.c:1292:<- [3,"430",{}]
2025-10-31T15:59:49.015Z:COM:ocpp_rpc.c:715:-> [2,"431","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:49.015Z:COM:ocpp_rpc.c:715:0T13:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:49.015Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:49.066Z:COM:ocpp_rpc.c:1292:<- [3,"431",{}]
2025-10-31T15:59:49.152Z:COM:ocpp_rpc.c:715:-> [2,"432","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:49.152Z:COM:ocpp_rpc.c:715:0T13:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:49.152Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:49.207Z:COM:ocpp_rpc.c:1292:<- [3,"432",{}]
2025-10-31T15:59:49.292Z:COM:ocpp_rpc.c:715:-> [2,"433","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:49.292Z:COM:ocpp_rpc.c:715:0T13:42:48Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:49.292Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:49.339Z:COM:ocpp_rpc.c:1292:<- [3,"433",{}]
2025-10-31T15:59:49.425Z:COM:ocpp_rpc.c:715:-> [2,"434","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:49.425Z:COM:ocpp_rpc.c:715:0T13:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:49.425Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:49.468Z:COM:ocpp_rpc.c:1292:<- [3,"434",{}]
2025-10-31T15:59:49.550Z:COM:ocpp_rpc.c:715:-> [2,"435","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:49.550Z:COM:ocpp_rpc.c:715:0T14:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:49.550Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:49.597Z:COM:ocpp_rpc.c:1292:<- [3,"435",{}]
2025-10-31T15:59:49.683Z:COM:ocpp_rpc.c:715:-> [2,"436","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:49.683Z:COM:ocpp_rpc.c:715:0T14:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:49.683Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:49.730Z:COM:ocpp_rpc.c:1292:<- [3,"436",{}]
2025-10-31T15:59:49.812Z:COM:ocpp_rpc.c:715:-> [2,"437","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:49.812Z:COM:ocpp_rpc.c:715:0T14:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:49.812Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:49.890Z:COM:ocpp_rpc.c:1292:<- [3,"437",{}]
2025-10-31T15:59:49.972Z:COM:ocpp_rpc.c:715:-> [2,"438","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:49.972Z:COM:ocpp_rpc.c:715:0T14:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:49.972Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:50.027Z:COM:ocpp_rpc.c:1292:<- [3,"438",{}]
2025-10-31T15:59:50.109Z:COM:ocpp_rpc.c:715:-> [2,"439","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:50.109Z:COM:ocpp_rpc.c:715:0T15:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:50.109Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:50.156Z:COM:ocpp_rpc.c:1292:<- [3,"439",{}]
2025-10-31T15:59:50.242Z:COM:ocpp_rpc.c:715:-> [2,"440","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:50.242Z:COM:ocpp_rpc.c:715:0T15:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:50.242Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:50.289Z:COM:ocpp_rpc.c:1292:<- [3,"440",{}]
2025-10-31T15:59:50.375Z:COM:ocpp_rpc.c:715:-> [2,"441","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:50.375Z:COM:ocpp_rpc.c:715:0T15:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:50.375Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:50.417Z:COM:ocpp_rpc.c:1292:<- [3,"441",{}]
2025-10-31T15:59:50.500Z:COM:ocpp_rpc.c:715:-> [2,"442","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:50.500Z:COM:ocpp_rpc.c:715:0T15:57:48Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:50.500Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:50.546Z:COM:ocpp_rpc.c:1292:<- [3,"442",{}]
2025-10-31T15:59:50.632Z:COM:ocpp_rpc.c:715:-> [2,"443","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:50.632Z:COM:ocpp_rpc.c:715:0T16:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:50.632Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:50.679Z:COM:ocpp_rpc.c:1292:<- [3,"443",{}]
2025-10-31T15:59:50.761Z:COM:ocpp_rpc.c:715:-> [2,"444","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:50.761Z:COM:ocpp_rpc.c:715:0T16:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:50.761Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:50.808Z:COM:ocpp_rpc.c:1292:<- [3,"444",{}]
2025-10-31T15:59:50.890Z:COM:ocpp_rpc.c:715:-> [2,"445","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:50.890Z:COM:ocpp_rpc.c:715:0T16:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:50.890Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:50.937Z:COM:ocpp_rpc.c:1292:<- [3,"445",{}]
2025-10-31T15:59:51.023Z:COM:ocpp_rpc.c:715:-> [2,"446","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:51.023Z:COM:ocpp_rpc.c:715:0T16:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:51.023Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:51.070Z:COM:ocpp_rpc.c:1292:<- [3,"446",{}]
2025-10-31T15:59:51.152Z:COM:ocpp_rpc.c:715:-> [2,"447","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:51.152Z:COM:ocpp_rpc.c:715:0T17:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:51.152Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:51.195Z:COM:ocpp_rpc.c:1292:<- [3,"447",{}]
2025-10-31T15:59:51.281Z:COM:ocpp_rpc.c:715:-> [2,"448","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:51.281Z:COM:ocpp_rpc.c:715:0T17:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:51.281Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:51.328Z:COM:ocpp_rpc.c:1292:<- [3,"448",{}]
2025-10-31T15:59:51.414Z:COM:ocpp_rpc.c:715:-> [2,"449","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:51.414Z:COM:ocpp_rpc.c:715:0T17:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:51.414Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:51.460Z:COM:ocpp_rpc.c:1292:<- [3,"449",{}]
2025-10-31T15:59:51.542Z:COM:ocpp_rpc.c:715:-> [2,"450","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:51.542Z:COM:ocpp_rpc.c:715:0T17:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:51.542Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:51.585Z:COM:ocpp_rpc.c:1292:<- [3,"450",{}]
2025-10-31T15:59:51.671Z:COM:ocpp_rpc.c:715:-> [2,"451","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:51.671Z:COM:ocpp_rpc.c:715:0T18:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:51.671Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:51.718Z:COM:ocpp_rpc.c:1292:<- [3,"451",{}]
2025-10-31T15:59:51.800Z:COM:ocpp_rpc.c:715:-> [2,"452","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:51.800Z:COM:ocpp_rpc.c:715:0T18:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:51.800Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:51.851Z:COM:ocpp_rpc.c:1292:<- [3,"452",{}]
2025-10-31T15:59:51.933Z:COM:ocpp_rpc.c:715:-> [2,"453","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:51.933Z:COM:ocpp_rpc.c:715:0T18:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:51.933Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:51.976Z:COM:ocpp_rpc.c:1292:<- [3,"453",{}]
2025-10-31T15:59:52.066Z:COM:ocpp_rpc.c:715:-> [2,"454","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:52.066Z:COM:ocpp_rpc.c:715:0T18:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:52.066Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:52.109Z:COM:ocpp_rpc.c:1292:<- [3,"454",{}]
2025-10-31T15:59:52.191Z:COM:ocpp_rpc.c:715:-> [2,"455","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:52.191Z:COM:ocpp_rpc.c:715:0T19:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:52.191Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:52.250Z:COM:ocpp_rpc.c:1292:<- [3,"455",{}]
2025-10-31T15:59:52.335Z:COM:ocpp_rpc.c:715:-> [2,"456","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:52.335Z:COM:ocpp_rpc.c:715:0T19:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:52.335Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:52.386Z:COM:ocpp_rpc.c:1292:<- [3,"456",{}]
2025-10-31T15:59:52.468Z:COM:ocpp_rpc.c:715:-> [2,"457","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:52.468Z:COM:ocpp_rpc.c:715:0T19:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:52.468Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:52.531Z:COM:ocpp_rpc.c:1292:<- [3,"457",{}]
2025-10-31T15:59:52.613Z:COM:ocpp_rpc.c:715:-> [2,"458","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:52.613Z:COM:ocpp_rpc.c:715:0T19:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:52.613Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:52.656Z:COM:ocpp_rpc.c:1292:<- [3,"458",{}]
2025-10-31T15:59:52.742Z:COM:ocpp_rpc.c:715:-> [2,"459","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:52.742Z:COM:ocpp_rpc.c:715:0T20:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:52.742Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:52.796Z:COM:ocpp_rpc.c:1292:<- [3,"459",{}]
2025-10-31T15:59:52.882Z:COM:ocpp_rpc.c:715:-> [2,"460","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:52.882Z:COM:ocpp_rpc.c:715:0T20:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:52.882Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:52.937Z:COM:ocpp_rpc.c:1292:<- [3,"460",{}]
2025-10-31T15:59:53.023Z:COM:ocpp_rpc.c:715:-> [2,"461","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:53.023Z:COM:ocpp_rpc.c:715:0T20:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:53.023Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:53.078Z:COM:ocpp_rpc.c:1292:<- [3,"461",{}]
2025-10-31T15:59:53.164Z:COM:ocpp_rpc.c:715:-> [2,"462","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:53.164Z:COM:ocpp_rpc.c:715:0T20:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:53.164Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:53.207Z:COM:ocpp_rpc.c:1292:<- [3,"462",{}]
2025-10-31T15:59:53.292Z:COM:ocpp_rpc.c:715:-> [2,"463","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:53.292Z:COM:ocpp_rpc.c:715:0T21:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:53.292Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:53.339Z:COM:ocpp_rpc.c:1292:<- [3,"463",{}]
2025-10-31T15:59:53.421Z:COM:ocpp_rpc.c:715:-> [2,"464","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:53.421Z:COM:ocpp_rpc.c:715:0T21:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:53.421Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:53.468Z:COM:ocpp_rpc.c:1292:<- [3,"464",{}]
2025-10-31T15:59:53.550Z:COM:ocpp_rpc.c:715:-> [2,"465","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:53.550Z:COM:ocpp_rpc.c:715:0T21:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:53.550Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:53.597Z:COM:ocpp_rpc.c:1292:<- [3,"465",{}]
2025-10-31T15:59:53.683Z:COM:ocpp_rpc.c:715:-> [2,"466","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:53.683Z:COM:ocpp_rpc.c:715:0T21:57:48Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:53.683Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:53.730Z:COM:ocpp_rpc.c:1292:<- [3,"466",{}]
2025-10-31T15:59:53.816Z:COM:ocpp_rpc.c:715:-> [2,"467","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:53.816Z:COM:ocpp_rpc.c:715:0T22:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:53.816Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:53.855Z:COM:ocpp_rpc.c:1292:<- [3,"467",{}]
2025-10-31T15:59:53.941Z:COM:ocpp_rpc.c:715:-> [2,"468","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:53.941Z:COM:ocpp_rpc.c:715:0T22:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:53.941Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:53.992Z:COM:ocpp_rpc.c:1292:<- [3,"468",{}]
2025-10-31T15:59:54.078Z:COM:ocpp_rpc.c:715:-> [2,"469","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:54.078Z:COM:ocpp_rpc.c:715:0T22:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:54.078Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:54.121Z:COM:ocpp_rpc.c:1292:<- [3,"469",{}]
2025-10-31T15:59:54.203Z:COM:ocpp_rpc.c:715:-> [2,"470","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:54.203Z:COM:ocpp_rpc.c:715:0T22:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:54.203Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:54.250Z:COM:ocpp_rpc.c:1292:<- [3,"470",{}]
2025-10-31T15:59:54.332Z:COM:ocpp_rpc.c:715:-> [2,"471","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:54.332Z:COM:ocpp_rpc.c:715:0T23:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:54.332Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:54.375Z:COM:ocpp_rpc.c:1292:<- [3,"471",{}]
2025-10-31T15:59:54.460Z:COM:ocpp_rpc.c:715:-> [2,"472","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:54.460Z:COM:ocpp_rpc.c:715:0T23:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:54.460Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:54.507Z:COM:ocpp_rpc.c:1292:<- [3,"472",{}]
2025-10-31T15:59:54.593Z:COM:ocpp_rpc.c:715:-> [2,"473","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:54.593Z:COM:ocpp_rpc.c:715:0T23:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:54.593Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:54.636Z:COM:ocpp_rpc.c:1292:<- [3,"473",{}]
2025-10-31T15:59:54.718Z:COM:ocpp_rpc.c:715:-> [2,"474","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:54.718Z:COM:ocpp_rpc.c:715:0T23:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:54.718Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:54.777Z:COM:ocpp_rpc.c:1292:<- [3,"474",{}]
2025-10-31T15:59:54.863Z:COM:ocpp_rpc.c:715:-> [2,"475","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:54.863Z:COM:ocpp_rpc.c:715:1T00:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:54.863Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:54.910Z:COM:ocpp_rpc.c:1292:<- [3,"475",{}]
2025-10-31T15:59:54.992Z:COM:ocpp_rpc.c:715:-> [2,"476","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:54.992Z:COM:ocpp_rpc.c:715:1T00:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:54.992Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:55.039Z:COM:ocpp_rpc.c:1292:<- [3,"476",{}]
2025-10-31T15:59:55.128Z:COM:ocpp_rpc.c:715:-> [2,"477","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:55.128Z:COM:ocpp_rpc.c:715:1T00:42:48Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:55.128Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:55.175Z:COM:ocpp_rpc.c:1292:<- [3,"477",{}]
2025-10-31T15:59:55.261Z:COM:ocpp_rpc.c:715:-> [2,"478","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:55.261Z:COM:ocpp_rpc.c:715:1T00:57:48Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:55.261Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:55.308Z:COM:ocpp_rpc.c:1292:<- [3,"478",{}]
2025-10-31T15:59:55.394Z:COM:ocpp_rpc.c:715:-> [2,"479","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:55.394Z:COM:ocpp_rpc.c:715:1T01:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:55.394Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:55.437Z:COM:ocpp_rpc.c:1292:<- [3,"479",{}]
2025-10-31T15:59:55.519Z:COM:ocpp_rpc.c:715:-> [2,"480","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:55.519Z:COM:ocpp_rpc.c:715:1T01:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:55.519Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:55.566Z:COM:ocpp_rpc.c:1292:<- [3,"480",{}]
2025-10-31T15:59:55.652Z:COM:ocpp_rpc.c:715:-> [2,"481","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:55.652Z:COM:ocpp_rpc.c:715:1T01:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:55.652Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:55.695Z:COM:ocpp_rpc.c:1292:<- [3,"481",{}]
2025-10-31T15:59:55.781Z:COM:ocpp_rpc.c:715:-> [2,"482","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:55.781Z:COM:ocpp_rpc.c:715:1T01:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:55.781Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:55.828Z:COM:ocpp_rpc.c:1292:<- [3,"482",{}]
2025-10-31T15:59:55.910Z:COM:ocpp_rpc.c:715:-> [2,"483","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:55.910Z:COM:ocpp_rpc.c:715:1T02:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:55.910Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:55.949Z:COM:ocpp_rpc.c:1292:<- [3,"483",{}]
2025-10-31T15:59:56.035Z:COM:ocpp_rpc.c:715:-> [2,"484","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:56.035Z:COM:ocpp_rpc.c:715:1T02:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:56.035Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:56.078Z:COM:ocpp_rpc.c:1292:<- [3,"484",{}]
2025-10-31T15:59:56.160Z:COM:ocpp_rpc.c:715:-> [2,"485","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:56.160Z:COM:ocpp_rpc.c:715:1T02:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:56.160Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:56.207Z:COM:ocpp_rpc.c:1292:<- [3,"485",{}]
2025-10-31T15:59:56.292Z:COM:ocpp_rpc.c:715:-> [2,"486","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:56.292Z:COM:ocpp_rpc.c:715:1T02:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:56.292Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:56.339Z:COM:ocpp_rpc.c:1292:<- [3,"486",{}]
2025-10-31T15:59:56.425Z:COM:ocpp_rpc.c:715:-> [2,"487","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:56.425Z:COM:ocpp_rpc.c:715:1T03:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:56.425Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:56.468Z:COM:ocpp_rpc.c:1292:<- [3,"487",{}]
2025-10-31T15:59:56.550Z:COM:ocpp_rpc.c:715:-> [2,"488","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:56.550Z:COM:ocpp_rpc.c:715:1T03:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:56.550Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:56.597Z:COM:ocpp_rpc.c:1292:<- [3,"488",{}]
2025-10-31T15:59:56.683Z:COM:ocpp_rpc.c:715:-> [2,"489","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:56.683Z:COM:ocpp_rpc.c:715:1T03:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:56.683Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:56.718Z:COM:ocpp_rpc.c:1292:<- [3,"489",{}]
2025-10-31T15:59:56.804Z:COM:ocpp_rpc.c:715:-> [2,"490","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:56.804Z:COM:ocpp_rpc.c:715:1T03:57:48Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:56.804Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:56.843Z:COM:ocpp_rpc.c:1292:<- [3,"490",{}]
2025-10-31T15:59:56.929Z:COM:ocpp_rpc.c:715:-> [2,"491","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:56.929Z:COM:ocpp_rpc.c:715:1T04:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:56.929Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:56.980Z:COM:ocpp_rpc.c:1292:<- [3,"491",{}]
2025-10-31T15:59:57.070Z:COM:ocpp_rpc.c:715:-> [2,"492","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:57.070Z:COM:ocpp_rpc.c:715:1T04:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:57.070Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:57.117Z:COM:ocpp_rpc.c:1292:<- [3,"492",{}]
2025-10-31T15:59:57.199Z:COM:ocpp_rpc.c:715:-> [2,"493","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:57.199Z:COM:ocpp_rpc.c:715:1T04:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:57.199Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:57.246Z:COM:ocpp_rpc.c:1292:<- [3,"493",{}]
2025-10-31T15:59:57.332Z:COM:ocpp_rpc.c:715:-> [2,"494","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:57.332Z:COM:ocpp_rpc.c:715:1T04:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:57.332Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:57.378Z:COM:ocpp_rpc.c:1292:<- [3,"494",{}]
2025-10-31T15:59:57.460Z:COM:ocpp_rpc.c:715:-> [2,"495","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:57.460Z:COM:ocpp_rpc.c:715:1T05:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:57.460Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:57.507Z:COM:ocpp_rpc.c:1292:<- [3,"495",{}]
2025-10-31T15:59:57.593Z:COM:ocpp_rpc.c:715:-> [2,"496","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:57.593Z:COM:ocpp_rpc.c:715:1T05:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:57.593Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:57.640Z:COM:ocpp_rpc.c:1292:<- [3,"496",{}]
2025-10-31T15:59:57.722Z:COM:ocpp_rpc.c:715:-> [2,"497","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:57.722Z:COM:ocpp_rpc.c:715:1T05:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:57.722Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:57.765Z:COM:ocpp_rpc.c:1292:<- [3,"497",{}]
2025-10-31T15:59:57.851Z:COM:ocpp_rpc.c:715:-> [2,"498","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:57.851Z:COM:ocpp_rpc.c:715:1T05:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:57.851Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:57.886Z:COM:ocpp_rpc.c:1292:<- [3,"498",{}]
2025-10-31T15:59:57.972Z:COM:ocpp_rpc.c:715:-> [2,"499","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:57.972Z:COM:ocpp_rpc.c:715:1T06:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:57.972Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:58.019Z:COM:ocpp_rpc.c:1292:<- [3,"499",{}]
2025-10-31T15:59:58.105Z:COM:ocpp_rpc.c:715:-> [2,"500","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:58.105Z:COM:ocpp_rpc.c:715:1T06:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:58.105Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:58.148Z:COM:ocpp_rpc.c:1292:<- [3,"500",{}]
2025-10-31T15:59:58.234Z:COM:ocpp_rpc.c:715:-> [2,"501","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:58.234Z:COM:ocpp_rpc.c:715:1T06:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:58.234Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:58.289Z:COM:ocpp_rpc.c:1292:<- [3,"501",{}]
2025-10-31T15:59:58.371Z:COM:ocpp_rpc.c:715:-> [2,"502","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:58.371Z:COM:ocpp_rpc.c:715:1T06:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:58.371Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:58.417Z:COM:ocpp_rpc.c:1292:<- [3,"502",{}]
2025-10-31T15:59:58.503Z:COM:ocpp_rpc.c:715:-> [2,"503","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:58.503Z:COM:ocpp_rpc.c:715:1T07:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:58.503Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:58.546Z:COM:ocpp_rpc.c:1292:<- [3,"503",{}]
2025-10-31T15:59:58.628Z:COM:ocpp_rpc.c:715:-> [2,"504","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:58.628Z:COM:ocpp_rpc.c:715:1T07:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:58.628Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:58.679Z:COM:ocpp_rpc.c:1292:<- [3,"504",{}]
2025-10-31T15:59:58.761Z:COM:ocpp_rpc.c:715:-> [2,"505","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:58.761Z:COM:ocpp_rpc.c:715:1T07:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:58.761Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:58.808Z:COM:ocpp_rpc.c:1292:<- [3,"505",{}]
2025-10-31T15:59:58.894Z:COM:ocpp_rpc.c:715:-> [2,"506","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:58.894Z:COM:ocpp_rpc.c:715:1T07:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:58.894Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:58.945Z:COM:ocpp_rpc.c:1292:<- [3,"506",{}]
2025-10-31T15:59:59.031Z:COM:ocpp_rpc.c:715:-> [2,"507","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:59.031Z:COM:ocpp_rpc.c:715:1T08:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:59.031Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:59.089Z:COM:ocpp_rpc.c:1292:<- [3,"507",{}]
2025-10-31T15:59:59.171Z:COM:ocpp_rpc.c:715:-> [2,"508","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:59.171Z:COM:ocpp_rpc.c:715:1T08:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:59.171Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:59.218Z:COM:ocpp_rpc.c:1292:<- [3,"508",{}]
2025-10-31T15:59:59.304Z:COM:ocpp_rpc.c:715:-> [2,"509","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:59.304Z:COM:ocpp_rpc.c:715:1T08:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:59.304Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:59.347Z:COM:ocpp_rpc.c:1292:<- [3,"509",{}]
2025-10-31T15:59:59.433Z:COM:ocpp_rpc.c:715:-> [2,"510","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:59.433Z:COM:ocpp_rpc.c:715:1T08:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:59.433Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:59.488Z:COM:ocpp_rpc.c:1292:<- [3,"510",{}]
2025-10-31T15:59:59.574Z:COM:ocpp_rpc.c:715:-> [2,"511","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:59.574Z:COM:ocpp_rpc.c:715:1T09:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:59.574Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:59.617Z:COM:ocpp_rpc.c:1292:<- [3,"511",{}]
2025-10-31T15:59:59.699Z:COM:ocpp_rpc.c:715:-> [2,"512","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:59.699Z:COM:ocpp_rpc.c:715:1T09:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:59.699Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:59.746Z:COM:ocpp_rpc.c:1292:<- [3,"512",{}]
2025-10-31T15:59:59.832Z:COM:ocpp_rpc.c:715:-> [2,"513","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:59.832Z:COM:ocpp_rpc.c:715:1T09:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:59.832Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T15:59:59.878Z:COM:ocpp_rpc.c:1292:<- [3,"513",{}]
2025-10-31T15:59:59.960Z:COM:ocpp_rpc.c:715:-> [2,"514","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T15:59:59.960Z:COM:ocpp_rpc.c:715:1T09:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T15:59:59.960Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:00.000Z:COM:ocpp_rpc.c:1292:<- [3,"514",{}]
2025-10-31T16:00:00.089Z:COM:ocpp_rpc.c:715:-> [2,"515","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:00.089Z:COM:ocpp_rpc.c:715:1T10:12:48Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:00.089Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:00.128Z:COM:ocpp_rpc.c:1292:<- [3,"515",{}]
2025-10-31T16:00:00.214Z:COM:ocpp_rpc.c:715:-> [2,"516","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:00.214Z:COM:ocpp_rpc.c:715:1T10:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:00.214Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:00.257Z:COM:ocpp_rpc.c:1292:<- [3,"516",{}]
2025-10-31T16:00:00.339Z:COM:ocpp_rpc.c:715:-> [2,"517","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:00.339Z:COM:ocpp_rpc.c:715:1T10:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:00.339Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:00.386Z:COM:ocpp_rpc.c:1292:<- [3,"517",{}]
2025-10-31T16:00:00.472Z:COM:ocpp_rpc.c:715:-> [2,"518","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:00.472Z:COM:ocpp_rpc.c:715:1T10:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:00.472Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:00.519Z:COM:ocpp_rpc.c:1292:<- [3,"518",{}]
2025-10-31T16:00:00.605Z:COM:ocpp_rpc.c:715:-> [2,"519","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:00.605Z:COM:ocpp_rpc.c:715:1T11:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:00.605Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:00.644Z:COM:ocpp_rpc.c:1292:<- [3,"519",{}]
2025-10-31T16:00:00.726Z:COM:ocpp_rpc.c:715:-> [2,"520","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:00.726Z:COM:ocpp_rpc.c:715:1T11:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:00.726Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:00.777Z:COM:ocpp_rpc.c:1292:<- [3,"520",{}]
2025-10-31T16:00:00.863Z:COM:ocpp_rpc.c:715:-> [2,"521","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:00.863Z:COM:ocpp_rpc.c:715:1T11:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:00.863Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:00.902Z:COM:ocpp_rpc.c:1292:<- [3,"521",{}]
2025-10-31T16:00:00.988Z:COM:ocpp_rpc.c:715:-> [2,"522","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:00.988Z:COM:ocpp_rpc.c:715:1T11:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:00.988Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:01.027Z:COM:ocpp_rpc.c:1292:<- [3,"522",{}]
2025-10-31T16:00:01.117Z:COM:ocpp_rpc.c:715:-> [2,"523","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:01.117Z:COM:ocpp_rpc.c:715:1T12:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:01.117Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:01.156Z:COM:ocpp_rpc.c:1292:<- [3,"523",{}]
2025-10-31T16:00:01.242Z:COM:ocpp_rpc.c:715:-> [2,"524","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:01.242Z:COM:ocpp_rpc.c:715:1T12:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:01.242Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:01.281Z:COM:ocpp_rpc.c:1292:<- [3,"524",{}]
2025-10-31T16:00:01.363Z:COM:ocpp_rpc.c:715:-> [2,"525","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:01.363Z:COM:ocpp_rpc.c:715:1T12:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:01.363Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:01.402Z:COM:ocpp_rpc.c:1292:<- [3,"525",{}]
2025-10-31T16:00:01.492Z:COM:ocpp_rpc.c:715:-> [2,"526","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:01.492Z:COM:ocpp_rpc.c:715:1T12:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:01.492Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:01.535Z:COM:ocpp_rpc.c:1292:<- [3,"526",{}]
2025-10-31T16:00:01.621Z:COM:ocpp_rpc.c:715:-> [2,"527","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:01.621Z:COM:ocpp_rpc.c:715:1T13:12:48Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:01.621Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:01.667Z:COM:ocpp_rpc.c:1292:<- [3,"527",{}]
2025-10-31T16:00:01.753Z:COM:ocpp_rpc.c:715:-> [2,"528","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:01.753Z:COM:ocpp_rpc.c:715:1T13:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:01.753Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:01.792Z:COM:ocpp_rpc.c:1292:<- [3,"528",{}]
2025-10-31T16:00:01.875Z:COM:ocpp_rpc.c:715:-> [2,"529","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:01.875Z:COM:ocpp_rpc.c:715:1T13:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:01.875Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:01.914Z:COM:ocpp_rpc.c:1292:<- [3,"529",{}]
2025-10-31T16:00:02.000Z:COM:ocpp_rpc.c:715:-> [2,"530","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:02.000Z:COM:ocpp_rpc.c:715:1T13:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:02.000Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:02.046Z:COM:ocpp_rpc.c:1292:<- [3,"530",{}]
2025-10-31T16:00:02.132Z:COM:ocpp_rpc.c:715:-> [2,"531","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:02.132Z:COM:ocpp_rpc.c:715:1T14:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:02.132Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:02.167Z:COM:ocpp_rpc.c:1292:<- [3,"531",{}]
2025-10-31T16:00:02.253Z:COM:ocpp_rpc.c:715:-> [2,"532","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:02.253Z:COM:ocpp_rpc.c:715:1T14:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:02.253Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:02.289Z:COM:ocpp_rpc.c:1292:<- [3,"532",{}]
2025-10-31T16:00:02.375Z:COM:ocpp_rpc.c:715:-> [2,"533","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:02.375Z:COM:ocpp_rpc.c:715:1T14:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:02.375Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:02.417Z:COM:ocpp_rpc.c:1292:<- [3,"533",{}]
2025-10-31T16:00:02.500Z:COM:ocpp_rpc.c:715:-> [2,"534","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:02.500Z:COM:ocpp_rpc.c:715:1T14:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:02.500Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:02.546Z:COM:ocpp_rpc.c:1292:<- [3,"534",{}]
2025-10-31T16:00:02.632Z:COM:ocpp_rpc.c:715:-> [2,"535","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:02.632Z:COM:ocpp_rpc.c:715:1T15:12:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:02.632Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:02.675Z:COM:ocpp_rpc.c:1292:<- [3,"535",{}]
2025-10-31T16:00:02.761Z:COM:ocpp_rpc.c:715:-> [2,"536","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:02.761Z:COM:ocpp_rpc.c:715:1T15:27:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:02.761Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:02.808Z:COM:ocpp_rpc.c:1292:<- [3,"536",{}]
2025-10-31T16:00:02.894Z:COM:ocpp_rpc.c:715:-> [2,"537","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:02.894Z:COM:ocpp_rpc.c:715:1T15:42:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:02.894Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:02.929Z:COM:ocpp_rpc.c:1292:<- [3,"537",{}]
2025-10-31T16:00:03.015Z:COM:ocpp_rpc.c:715:-> [2,"538","MeterValues",{"connectorId":1,"meterValue":[{"timestamp":"2025-10-3
2025-10-31T16:00:03.015Z:COM:ocpp_rpc.c:715:1T15:57:47Z","sampledValue":[{"value":"5540.316","context":"Sample.Periodic","me
2025-10-31T16:00:03.015Z:COM:ocpp_rpc.c:715:asurand":"Energy.Active.Import.Register","location":"Outlet","unit":"kWh"}]}]}]
2025-10-31T16:00:03.054Z:COM:ocpp_rpc.c:1292:<- [3,"538",{}]
2025-10-31T16:01:07.460Z:INFO:taskMaster.c:4875:Socket #1: state main : WAIT_FOR_DISCONNECT
2025-10-31T16:01:07.472Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_A
2025-10-31T16:01:08.011Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_ON_BYPASS_OFF
2025-10-31T16:01:08.527Z:INFO:board_ng9xx.c:5628:Socket 1: emergency relays check OK
2025-10-31T16:01:08.562Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_OFF_BYPASS_OFF
2025-10-31T16:01:09.039Z:INFO:taskMain.c:6230:Socket #1: Active current 16.0->0.0 due to current limit: Cable
2025-10-31T16:01:09.050Z:INFO:taskMain.c:6730:Socket #1: CPhigh 12.3 V
2025-10-31T16:01:09.054Z:INFO:taskMain.c:6735:Socket #1: CPlow 12.4 V
2025-10-31T16:01:09.062Z:INFO:taskMain.c:6740:Socket #1: PP 34464 Ohm (0 A)
2025-10-31T16:01:09.113Z:INFO:taskMaster.c:4875:Socket #1: state main : AVAILABLE
2025-10-31T16:01:09.121Z:INFO:taskMain.c:6676:Socket #1: active tag cleared
2025-10-31T16:01:09.171Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_E
2025-10-31T16:01:09.179Z:INFO:taskMaster.c:4897:Socket #1: state led : INOPERATIVE
2025-10-31T16:01:09.187Z:COM:ocpp_rpc.c:715:-> [2,"539","StatusNotification",{"connectorId":1,"errorCode":"NoError","status"
2025-10-31T16:01:09.187Z:COM:ocpp_rpc.c:715::"Unavailable"}]
2025-10-31T16:01:09.207Z:INFO:taskMaster.c:4875:Socket #1: state main : INOPERATIVE
2025-10-31T16:01:09.238Z:COM:ocpp_rpc.c:1292:<- [3,"539",{}]
2025-10-31T16:01:10.039Z:INFO:taskMain.c:6730:Socket #1: CPhigh 0.0 V
2025-10-31T16:01:10.046Z:INFO:taskMain.c:6735:Socket #1: CPlow 0.0 V
2025-10-31T16:01:10.199Z:INFO:taskMain.c:1426:Socket #1: main state: INOPERATIVE, CP: 0.0/0.0, no tag
2025-10-31T16:01:24.285Z:INFO:taskMain.c:6230:Socket #1: Active current 0.0->16.0 due to current limit: Connector-MaxCurrent,
2025-10-31T16:01:24.285Z:INFO:taskMain.c:6230:Simplified-Mode3, ChargingProfile, Start
2025-10-31T16:01:24.335Z:INFO:taskMain.c:6740:Socket #1: PP 701 Ohm (20 A)
2025-10-31T16:01:26.660Z:USER:tag.c:1620:Reader 0 Got NFC tag: 04BB29EAFD0F94
2025-10-31T16:01:29.304Z:INFO:taskMain.c:6230:Socket #1: Active current 16.0->0.0 due to current limit: Cable
2025-10-31T16:01:29.386Z:INFO:taskMain.c:6740:Socket #1: PP 34464 Ohm (0 A)
2025-10-31T16:02:35.457Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:02:35.773Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-31T16:02:36.105Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-31T16:02:36.167Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-10-31T16:02:36.558Z:SECURITY:web_functionalit:68:Changed '2059_00' from 1761926563999 => 1761926557522
2025-10-31T16:02:51.148Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-10-31T16:03:02.117Z:WARNING:taskWebClient.c:234:Client (fd=2) disconnected (r: -0x50)
2025-10-31T16:03:02.125Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-31T16:03:02.234Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-31T16:03:26.425Z:INFO:active_lb.c:308:SMt:(2.0 3.0 2.0)A Free:(23.0 22.0 23.0)A ALB:(23.2 22.0 23.0)A
2025-10-31T16:04:25.218Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:04:25.539Z:SECURITY:httpd_login.c:149:Invalid password for user: 'admin'
2025-10-31T16:04:25.546Z:WARNING:web_functionali:101:Invalid username/password provided. Login not allowed
2025-10-31T16:04:36.007Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-31T16:04:36.296Z:WARNING:web_functionalit:48:Failed to parse property '2068_1'
2025-10-31T16:04:36.304Z:WARNING:web_functionalit:48:Failed to parse property '2068_2'
2025-10-31T16:04:36.316Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-10-31T16:04:36.824Z:WARNING:web_functionalit:48:Failed to parse property '8006_0'
2025-10-31T16:04:36.972Z:WARNING:web_functionalit:48:Failed to parse property '8201_0'
2025-10-31T16:04:36.980Z:WARNING:web_functionalit:48:Failed to parse property '8202_0'
2025-10-31T16:04:36.988Z:WARNING:web_functionalit:48:Failed to parse property '8203_0'
2025-10-31T16:04:37.000Z:WARNING:web_functionalit:48:Failed to parse property '8301_0'
2025-10-31T16:04:37.007Z:WARNING:web_functionalit:48:Failed to parse property '8302_0'
2025-10-31T16:04:37.128Z:WARNING:web_functionalit:48:Failed to parse property '8303_0'
2025-10-31T16:04:37.140Z:WARNING:web_functionalit:48:Failed to parse property '8101_1'
2025-10-31T16:04:37.148Z:WARNING:web_functionalit:48:Failed to parse property '8101_2'
2025-10-31T16:04:37.160Z:WARNING:web_functionalit:48:Failed to parse property '8102_1'
2025-10-31T16:04:37.167Z:WARNING:web_functionalit:48:Failed to parse property '8102_2'
2025-10-31T16:04:37.175Z:WARNING:web_functionalit:48:Failed to parse property '8103_1'
2025-10-31T16:04:37.187Z:WARNING:web_functionalit:48:Failed to parse property '8103_2'
2025-10-31T16:04:37.195Z:WARNING:web_functionalit:48:Failed to parse property '8108_1'
2025-10-31T16:04:37.203Z:WARNING:web_functionalit:48:Failed to parse property '8108_2'
2025-10-31T16:04:37.214Z:WARNING:web_functionalit:48:Failed to parse property '8107_1'
2025-10-31T16:04:37.222Z:WARNING:web_functionalit:48:Failed to parse property '8107_2'
2025-10-31T16:04:37.234Z:WARNING:web_functionalit:48:Failed to parse property '810A_1'
2025-10-31T16:04:37.242Z:WARNING:web_functionalit:48:Failed to parse property '810A_2'
2025-10-31T16:04:37.250Z:WARNING:web_functionalit:48:Failed to parse property '8109_1'
2025-10-31T16:04:37.261Z:WARNING:web_functionalit:48:Failed to parse property '8109_2'
2025-10-31T16:04:37.425Z:WARNING:web_functionalit:48:Failed to parse property '2188_0'
2025-10-31T16:04:51.667Z:USER:taskMaster.c:6497:Temperature: 25.6 C
2025-10-31T16:05:03.316Z:INFO:web_functionali:159:Executing command: 'reboot'
2025-10-31T16:05:03.417Z:SECURITY:application.c:792:reset: requested, going down..
2025-10-31T16:05:15.515Z:RESET:application.c:414:==========================================
2025-10-31T16:05:15.527Z:INFO:application.c:421:build: May 28 2025 07:33:28
2025-10-31T16:05:15.535Z:INFO:application.c:422:version: 7.2.0-4362
2025-10-31T16:05:15.542Z:INFO:application.c:423:compiler: gcc 9.3.1
2025-10-31T16:05:15.550Z:INFO:application.c:285:fwu state inactive
2025-10-31T16:05:15.558Z:INFO:application.c:292:Bootloader version 2.2.2
2025-10-31T16:05:15.964Z:USER:taskCANopen.c:241:Persistent configuration retrieved, 282 items
2025-10-31T16:05:15.980Z:INFO:application.c:328:FLASH read protection 0xcc level 2 (permanent)
2025-10-31T16:05:15.992Z:USER:application.c:470:Using P1 port
2025-10-31T16:05:15.996Z:INFO:application.c:364:System boot #7, cause Software reset
2025-10-31T16:05:16.007Z:INFO:board_ng9xx.c:1649:Registered timeout getHardware
2025-10-31T16:05:17.714Z:INFO:bspMotors.c:616:Socket #1: Timeout while waiting for Cover motor
2025-10-31T16:05:18.824Z:INFO:board_ng9xx.c:5628:Socket 1: emergency relays check OK
2025-10-31T16:05:19.332Z:INFO:board_ng9xx.c:1676:Unregistered timeout getHardware
2025-10-31T16:05:19.339Z:INFO:application.c:510:ST MCU ID......................20036419
2025-10-31T16:05:19.351Z:INFO:application.c:511:Device ID:.....................004000203531510532353530
2025-10-31T16:05:19.363Z:INFO:application.c:512:Object ID:.....................ACE0640314
2025-10-31T16:05:19.371Z:INFO:application.c:513:#Sockets.......................1
2025-10-31T16:05:19.378Z:INFO:application.c:514:MAC address eeprom.............not available
2025-10-31T16:05:19.390Z:INFO:application.c:515:Configuration eeprom...........available
2025-10-31T16:05:19.398Z:INFO:application.c:517:Flash EEPROM...................available: manuf. 0x00c2, id 0x2016 (8 MB)
2025-10-31T16:05:19.410Z:INFO:application.c:520:Temperature sensor.............available (19.5/43.1 °C)
2025-10-31T16:05:19.421Z:INFO:application.c:521:Accelerometer/tilt sensor......not available
2025-10-31T16:05:19.429Z:INFO:application.c:522:Ambient light/proximity sensor.not available
2025-10-31T16:05:19.441Z:INFO:application.c:523:Real time clock................available
2025-10-31T16:05:19.449Z:INFO:application.c:524:Mobile network modem...........Autodetect (enabled)
2025-10-31T16:05:19.460Z:INFO:application.c:525:Ethernet PHY...................available
2025-10-31T16:05:19.667Z:INFO:application.c:534:#1 Control Pilot circuit.......available (0.2/-11.7 Volts)
2025-10-31T16:05:19.679Z:INFO:application.c:535:#1 Proximity Pin circuit.......available (100000 Ohms)
2025-10-31T16:05:19.691Z:INFO:application.c:536:#1 Socket motor................available
2025-10-31T16:05:19.699Z:INFO:application.c:537:#1 Cover motor.................not available
2025-10-31T16:05:19.710Z:INFO:application.c:538:#1 Auxiliary I/O...............not available
2025-10-31T16:05:19.718Z:INFO:application.c:539:#1 Button input................not available
2025-10-31T16:05:19.726Z:INFO:application.c:540:#1 NFC reader..................not available
2025-10-31T16:05:19.738Z:INFO:application.c:541:#1 Emergency relays............available
2025-10-31T16:05:19.746Z:INFO:application.c:560:-12V power supply..............available
2025-10-31T16:05:19.757Z:INFO:application.c:561:Smart meter P1 port interface..available
2025-10-31T16:05:19.765Z:INFO:application.c:562:Smart meter Suspend input......not available
2025-10-31T16:05:19.777Z:INFO:application.c:563:Smart meter external Modbus....available
2025-10-31T16:05:19.785Z:INFO:application.c:564:Energy meter ModBus interface..available
2025-10-31T16:05:19.792Z:INFO:application.c:565:Display user interface.........available
2025-10-31T16:05:19.804Z:INFO:application.c:566:PWM Buzzer.....................not available
2025-10-31T16:05:19.812Z:INFO:application.c:569:Auxiliary Board................supported
2025-10-31T16:05:19.824Z:INFO:application.c:570:Auxiliary Board revision.......D
2025-10-31T16:05:19.832Z:INFO:application.c:572:Powerboard revision/assy.......GUNKNOWN (32.0A)
2025-10-31T16:05:19.839Z:INFO:application.c:573:Controllerboard revision/assy..L7
2025-10-31T16:05:19.851Z:INFO:application.c:574:Powerboard relay type..........LATCHING_REVERSED
2025-10-31T16:05:19.859Z:INFO:application.c:592:Operational time ..............0D 00H
2025-10-31T16:05:19.875Z:INFO:db_common.c:147:Initializing all databases..
2025-10-31T16:05:20.296Z:INFO:db_base.c:1325:Initialized Transaction db (firstItem=0x00000000, lastItem=0x00001877)
2025-10-31T16:05:20.312Z:INFO:db_base.c:1325:Initialized LocalList db (firstItem=0x00000000, lastItem=0x00000000)
2025-10-31T16:05:20.328Z:INFO:db_base.c:1325:Initialized WhiteList db (firstItem=0x00000000, lastItem=0x00000041)
2025-10-31T16:05:20.343Z:INFO:db_base.c:1325:Initialized ChargingProfile db (firstItem=0x00000000, lastItem=0x000001b1)
2025-10-31T16:05:20.375Z:INFO:db_chargingprofi:75:Defragmented (#0/0, 19ms)
2025-10-31T16:05:20.382Z:INFO:db_chargingprofi:19:Max 45 charging profiles of 100 periods
2025-10-31T16:05:20.390Z:INFO:db_base.c:1325:Initialized Domain db (firstItem=0x00000000, lastItem=0x00000070)
2025-10-31T16:05:20.406Z:USER:ocpp.c:187:Init OCPP for ocpp1.6
2025-10-31T16:05:20.414Z:INFO:board_ng9xx.c:1649:Registered timeout BootNotification
2025-10-31T16:05:20.453Z:INFO:featureKeys.c:75:Unlocked Features: SCN,RFID-reader,4G (80010101)
2025-10-31T16:05:20.460Z:INFO:taskMain.c:604:Socket #1: Authorisation method COM unit via CAN
2025-10-31T16:05:20.472Z:INFO:taskMain.c:607:Socket #1: SocketType Mennekes
2025-10-31T16:05:20.480Z:INFO:taskMain.c:611:Socket #1: startup delay 5 s
2025-10-31T16:05:20.492Z:INFO:board_ng9xx.c:1649:Registered timeout NUVVE
2025-10-31T16:05:20.500Z:INFO:board_ng9xx.c:1649:Registered timeout NUVVE
2025-10-31T16:05:20.515Z:USER:EVsimulator.c:210:EV simulator initialised
2025-10-31T16:05:20.523Z:USER:taskMaster.c:1017:ocpp1.6 Smart Charging Mode
2025-10-31T16:05:20.738Z:INFO:bspEthernet.c:165:Ethernet PHY LAN8710@0x00
2025-10-31T16:05:20.750Z:INFO:taskMain.c:1299:charging_triac_starttime: 5
2025-10-31T16:05:20.757Z:INFO:taskMain.c:1300:charging_triac_keeptime : 50
2025-10-31T16:05:20.765Z:INFO:taskMain.c:1301:contactorstabletime : 50
2025-10-31T16:05:20.773Z:INFO:taskMain.c:1302:HFContactorSwitchTime : 60
2025-10-31T16:05:20.785Z:USER:bspEthernet.c:238:ETH PHY OK
2025-10-31T16:05:20.789Z:INFO:bspEthernet.c:217:MACAddress: [26:64:44:07:10:35]
2025-10-31T16:05:20.796Z:INFO:taskMain.c:6416:Socket #1: DSC initialised
2025-10-31T16:05:20.816Z:INFO:station.c:184:Active station current set to 25.0A max
2025-10-31T16:05:20.824Z:INFO:taskMain.c:6740:Socket #1: PP 34464 Ohm (0 A)
2025-10-31T16:05:20.832Z:INFO:taskMain.c:6746:Socket #1: PWM DC 10.0% (6.0 A)
2025-10-31T16:05:20.839Z:INFO:scn.c:686:Loadbalancing: Feature enabled
2025-10-31T16:05:20.847Z:INFO:scn.c:687:SCN: Feature enabled [Off]
2025-10-31T16:05:20.855Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-10-31T16:05:20.863Z:WARNING:scn_communicatio:75:SCN: Not enough sockets for an SCN!
2025-10-31T16:05:20.878Z:INFO:modem.c:1127:Modem state Idle->InitHw
2025-10-31T16:05:20.886Z:INFO:taskMeter.c:318:Starting smartmeter with protocol P1
2025-10-31T16:05:20.894Z:INFO:comConnect.c:295:Connectivity state: STARTUP
2025-10-31T16:05:20.902Z:INFO:taskModbus.c:4521:Address #1: modbus meter vendor : ALF
2025-10-31T16:05:20.914Z:INFO:taskModbus.c:4522:Address #1: modbus meter model : D3001
2025-10-31T16:05:20.921Z:INFO:taskModbus.c:4523:Address #1: modbus meter revision : V1.03
2025-10-31T16:05:20.933Z:INFO:taskModbus.c:4524:Address #1: modbus meter meterNumber : 22391493
2025-10-31T16:05:20.941Z:USER:taskModbus.c:933:Socket_1 Meter(1): meter type DZG_REALLIN found
2025-10-31T16:05:20.953Z:INFO:taskLeds.c:226:LED UI initialized OK
2025-10-31T16:05:21.437Z:USER:taskModbus.c:1104:Socket_1 Meter(1): first meter update, Multiple phase installation
2025-10-31T16:05:21.546Z:USER:taskMaster.c:1296:Node #1, version 7.2.0-4362
2025-10-31T16:05:21.746Z:INFO:taskNFCreader.c:579:Port #0 switch NFC power on
2025-10-31T16:05:21.757Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-31T16:05:21.769Z:INFO:taskCANopen.c:1200:Persistent memory not cached
2025-10-31T16:05:21.839Z:INFO:taskMain.c:1426:Socket #1: main state: BOOTING, CP: 0.0/0.0, no tag
2025-10-31T16:05:21.871Z:INFO:taskCANopen.c:2008:CanOpen EEPROM cache size: 282, got 282 objects <282,0>
2025-10-31T16:05:21.898Z:INFO:taskCANopen.c:1775:Updated object 0x2056, 4 bytes
2025-10-31T16:05:22.417Z:USER:bspEthernet.c:342:Mode: 100Mb/s full duplex
2025-10-31T16:05:22.425Z:INFO:taskTCPIP.c:953:Network Cable is now connected
2025-10-31T16:05:23.296Z:INFO:taskTCPIP.c:1577: IP address assigned by DHCP
2025-10-31T16:05:23.304Z:INFO:taskTCPIP.c:1605:Network interface is up
2025-10-31T16:05:23.312Z:INFO:taskTCPIP.c:1614: IP : 192.168.178.184
2025-10-31T16:05:23.324Z:INFO:taskTCPIP.c:1615: Netmask : 255.255.255.0
2025-10-31T16:05:23.332Z:INFO:taskTCPIP.c:1616: Gateway : 192.168.178.1
2025-10-31T16:05:23.339Z:INFO:taskTCPIP.c:1617: DNS1 : 192.168.178.1
2025-10-31T16:05:23.347Z:INFO:taskTCPIP.c:1618: DNS2 : 208.67.220.220
2025-10-31T16:05:23.355Z:INFO:taskTCPIP.c:512:Starting mDNS on interface al
2025-10-31T16:05:23.363Z:INFO:taskTCPIP.c:512:Starting Webserver on interface al
2025-10-31T16:05:23.371Z:INFO:taskTCPIP.c:512:Starting Modbus on interface al
2025-10-31T16:05:23.378Z:INFO:taskTCPIP.c:512:Starting P1 on interface al
2025-10-31T16:05:23.386Z:INFO:taskTCPIP.c:512:Starting SCN on interface al
2025-10-31T16:05:23.394Z:INFO:taskTCPIP.c:413:default network set to 'al'
2025-10-31T16:05:23.406Z:INFO:taskWebServer.c:238:WebServer state WAIT_FOR_NETWORK -> SETUP
2025-10-31T16:05:23.437Z:USER:taskWebServer.c:360:WebServer started on port 443
2025-10-31T16:05:23.449Z:INFO:taskWebServer.c:238:WebServer state SETUP -> AVAILABLE
2025-10-31T16:05:25.769Z:INFO:comConnect.c:1106:Connecting wired to: ws://192.168.178.140:8080/steve/websocket/CentralSystemServ
2025-10-31T16:05:25.769Z:INFO:comConnect.c:1106:ice/VAN_01971, prio #1
2025-10-31T16:05:25.855Z:INFO:comConnect.c:663:connection attempt 1/3
2025-10-31T16:05:25.886Z:INFO:comConnect.c:295:Connectivity state: INITIALISING
2025-10-31T16:05:25.921Z:INFO:taskNFCreader.c:115:Port #0 version response: "ICU NFC 243B (v3) v3.1-531"
2025-10-31T16:05:25.968Z:INFO:comConnect.c:295:Connectivity state: WIRED
2025-10-31T16:05:26.011Z:INFO:taskTCPIP.c:1486:'al' is configured as default internet connection.
2025-10-31T16:05:26.050Z:INFO:taskTCPIP.c:1503:Renew DHCP leash for interface 'al'.
2025-10-31T16:05:26.089Z:USER:comConnect.c:383:wired connect
2025-10-31T16:05:26.117Z:INFO:websockets.c:451:Connected to Socket 192.168.178.140:8080
2025-10-31T16:05:26.156Z:INFO:taskNFCreader.c:131:Port #0 ICU NFC reader BL3 v3.1, 1 LEDs
2025-10-31T16:05:26.195Z:INFO:taskNFCreader.c:132:Port #0 reader model: Giro-e
2025-10-31T16:05:26.230Z:INFO:websockets.c:2363:WS timeout: 10000 ms
2025-10-31T16:05:26.324Z:INFO:websockets.c:824:WebSocket upgrade successful
2025-10-31T16:05:26.363Z:USER:taskOCPP.c:464:Back office connection available
2025-10-31T16:05:26.441Z:USER:application.c:718:Initialisation done
2025-10-31T16:05:26.949Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:05:27.250Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-31T16:05:27.558Z:INFO:taskMaster.c:1104:Socket #1 has a Modbus meter
2025-10-31T16:05:27.570Z:INFO:updatefirmware.c:52:BL FWU_STATUS_INACTIVE -> int IDLE
2025-10-31T16:05:27.578Z:INFO:taskMain.c:1737:Socket #1: recovered INOPERATIVE
2025-10-31T16:05:27.585Z:USER:taskMaster.c:1131:1 NFC readers found
2025-10-31T16:05:27.609Z:INFO:taskMaster.c:1542:Socket #1: no open transaction
2025-10-31T16:05:27.617Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-31T16:05:27.636Z:INFO:smartMeter.c:80:Set phases: (L1, L2, L3)->(L1, L2, L3)
2025-10-31T16:05:27.644Z:INFO:active_lb.c:308:SMt:(0.0 0.0 0.0)A Free:(25.0 25.0 25.0)A ALB:(0.0 0.0 0.0)A
2025-10-31T16:05:27.656Z:INFO:taskMaster.c:4875:Socket #1: state main : INOPERATIVE
2025-10-31T16:05:27.664Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_OFF_BYPASS_OFF
2025-10-31T16:05:27.675Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_E
2025-10-31T16:05:27.683Z:INFO:taskMaster.c:4897:Socket #1: state led : CHECK_MAINS
2025-10-31T16:05:27.742Z:INFO:taskMaster.c:6294:Socket #1: no schedule
2025-10-31T16:05:27.750Z:USER:taskMaster.c:6318:Socket #1: external current limit 16.0 A
2025-10-31T16:05:27.761Z:INFO:station.c:97:station external max - new value: 99.9A
2025-10-31T16:05:27.769Z:INFO:comFaults.c:482:Reset fault status
2025-10-31T16:05:27.785Z:USER:taskMaster.c:1326:NFC version: ICU NFC 243B (v3) v3.1-531
2025-10-31T16:05:27.792Z:INFO:taskMaster.c:4897:Socket #1: state led : INOPERATIVE
2025-10-31T16:05:28.183Z:INFO:modem.c:1127:Modem state InitHw->InitModem
2025-10-31T16:05:28.191Z:INFO:modem.c:1299:Reset delay 2s
2025-10-31T16:05:28.699Z:INFO:taskMain.c:1426:Socket #1: main state: INOPERATIVE, CP: 0.0/0.0, no tag
2025-10-31T16:05:31.406Z:COM:ocpp_rpc.c:715:-> [2,"1","BootNotification",{"chargePointVendor":"Alfen BV","chargePointModel":
2025-10-31T16:05:31.406Z:COM:ocpp_rpc.c:715:"NG910-60583","chargePointSerialNumber":"ACE0640314","chargeBoxSerialNumber":"VA
2025-10-31T16:05:31.406Z:COM:ocpp_rpc.c:715:N_01971","firmwareVersion":"7.2.0-4362"}]
2025-10-31T16:05:31.546Z:COM:ocpp_rpc.c:1292:<- [3,"1",{"status":"Accepted","currentTime":"2025-10-31T16:05:32.200Z","interva
2025-10-31T16:05:31.546Z:COM:ocpp_rpc.c:1292:l":14400}]
2025-10-31T16:05:32.386Z:USER:modem.c:3614:Modem type: Quectel BG95-M3
2025-10-31T16:05:32.406Z:INFO:modem.c:3093:Check if modem responds
2025-10-31T16:05:32.445Z:INFO:modem.c:2980:Set flow control (on)
2025-10-31T16:05:32.613Z:INFO:modem.c:3133:Set type of logging
2025-10-31T16:05:37.785Z:INFO:comFaults.c:1075:#phases: socket #1 ''->'L1L2L3'
2025-10-31T16:05:41.644Z:COM:ocpp_rpc.c:715:-> [2,"2","StatusNotification",{"connectorId":0,"errorCode":"NoError","status":"
2025-10-31T16:05:41.644Z:COM:ocpp_rpc.c:715:Unavailable"}]
2025-10-31T16:05:41.695Z:COM:ocpp_rpc.c:1292:<- [3,"2",{}]
2025-10-31T16:05:41.703Z:COM:ocpp_rpc.c:715:-> [2,"3","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":"
2025-10-31T16:05:41.703Z:COM:ocpp_rpc.c:715:Unavailable"}]
2025-10-31T16:05:41.742Z:COM:ocpp_rpc.c:1292:<- [3,"3",{}]
2025-10-31T16:05:51.089Z:INFO:modem.c:2528:Check PIN
2025-10-31T16:05:54.863Z:WARNING:modem.c:2565:SIM error
2025-10-31T16:05:57.101Z:INFO:taskWifi.c:657:WiFi Module: Not Initialized --> Running
2025-10-31T16:05:58.671Z:INFO:wifi.c:451:Successfully started AP <ACE0640314> ip<192.168.1.1>
2025-10-31T16:05:58.683Z:INFO:taskWifi.c:928:Start WiFi AP
2025-10-31T16:05:58.691Z:WARNING:taskWifi.c:1007:Wifi config is not valid
2025-10-31T16:05:58.699Z:INFO:taskWifi.c:664:SoftAP: Not Initialized --> Enabled
2025-10-31T16:05:58.707Z:INFO:taskWifi.c:671:STA: Not Initialized --> Not Configured
2025-10-31T16:05:58.742Z:WARNING:modem.c:2565:SIM error
2025-10-31T16:06:02.621Z:WARNING:modem.c:2565:SIM error
2025-10-31T16:06:06.496Z:WARNING:modem.c:2565:SIM error
2025-10-31T16:06:06.601Z:INFO:modem.c:2575:Check PIN failed
2025-10-31T16:06:08.304Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-31T16:06:09.242Z:INFO:updatefirmware.:211:signature: PKCS1_PSS_SHA256_2048
2025-10-31T16:06:09.273Z:INFO:updatefirmware.:212:encryption: AES128
2025-10-31T16:06:09.281Z:SECURITY:updatefirmware.:226:UpdateFirmware file type: UPDATE_FIRMWARE_NG9xx_VERSION_01
2025-10-31T16:06:15.613Z:INFO:updatefirmware.:185:Firmware region erased
2025-10-31T16:06:21.527Z:INFO:modem.c:3294:Get other info
2025-10-31T16:06:44.214Z:USER:updatefirmware.:309:Download progress:
2025-10-31T16:06:44.222Z:USER:updatefirmware.:309: payload: 181136/1808144 [10%]
2025-10-31T16:06:54.636Z:WARNING:modem.c:2728:AT+CSQ, invalid value(99)
2025-10-31T16:07:14.300Z:USER:updatefirmware.:309:Download progress:
2025-10-31T16:07:14.308Z:USER:updatefirmware.:309: payload: 361728/1808144 [20%]
2025-10-31T16:07:26.617Z:INFO:modem.c:3316:Signal strength : Unknown
2025-10-31T16:07:26.625Z:INFO:modem.c:3318:Radio Access Tech : 4G
2025-10-31T16:07:26.632Z:INFO:modem.c:3319:Registration mode : Disabled
2025-10-31T16:07:26.640Z:INFO:modem.c:3320:Registration status: Not registered
2025-10-31T16:07:26.648Z:INFO:modem.c:3321:Operator : 0
2025-10-31T16:07:26.656Z:INFO:modem.c:3322:Manufacturer : Quectel
2025-10-31T16:07:26.664Z:INFO:modem.c:3323:Modem module : BG95-M3
2025-10-31T16:07:26.671Z:INFO:modem.c:3324:Modem revision : BG95M3LAR02A03_01.012.01.012
2025-10-31T16:07:26.683Z:INFO:modem.c:3325:Modem IMEI : 864145067568848
2025-10-31T16:07:26.691Z:INFO:modem.c:3326:SIM IMSI :
2025-10-31T16:07:26.699Z:INFO:modem.c:3327:SIM ICCID :
2025-10-31T16:07:26.703Z:INFO:modem.c:3328:Modem supports 2G : yes
2025-10-31T16:07:26.710Z:INFO:modem.c:3329:Modem supports 3G : no
2025-10-31T16:07:26.718Z:INFO:modem.c:3330:Modem supports 4G : yes
2025-10-31T16:07:26.769Z:INFO:modem.c:3337:Cellinfo : "SEARCH"
2025-10-31T16:07:26.777Z:ERROR:modem.c:3367:Setup modem Failed
2025-10-31T16:07:26.785Z:INFO:modem.c:1127:Modem state InitModem->Stopping
2025-10-31T16:07:35.308Z:INFO:modem.c:1127:Modem state Stopping->Idle
2025-10-31T16:07:43.363Z:USER:updatefirmware.:309:Download progress:
2025-10-31T16:07:43.371Z:USER:updatefirmware.:309: payload: 543040/1808144 [30%]
2025-10-31T16:08:13.441Z:USER:updatefirmware.:309:Download progress:
2025-10-31T16:08:13.449Z:USER:updatefirmware.:309: payload: 723632/1808144 [40%]
2025-10-31T16:08:45.933Z:USER:updatefirmware.:309:Download progress:
2025-10-31T16:08:45.941Z:USER:updatefirmware.:309: payload: 904240/1808144 [50%]
2025-10-31T16:09:14.855Z:USER:updatefirmware.:309:Download progress:
2025-10-31T16:09:14.863Z:USER:updatefirmware.:309: payload: 1085536/1808144 [60%]
2025-10-31T16:09:41.304Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x50)
2025-10-31T16:09:41.316Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-31T16:09:41.394Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-31T16:09:50.726Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:09:51.050Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-31T16:09:51.273Z:WARNING:web_functionalit:48:Failed to parse property '2068_1'
2025-10-31T16:09:51.285Z:WARNING:web_functionalit:48:Failed to parse property '2068_2'
2025-10-31T16:09:51.296Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-10-31T16:09:51.718Z:WARNING:web_functionalit:48:Failed to parse property '8006_0'
2025-10-31T16:09:51.878Z:WARNING:web_functionalit:48:Failed to parse property '8201_0'
2025-10-31T16:09:51.890Z:WARNING:web_functionalit:48:Failed to parse property '8202_0'
2025-10-31T16:09:51.898Z:WARNING:web_functionalit:48:Failed to parse property '8203_0'
2025-10-31T16:09:51.910Z:WARNING:web_functionalit:48:Failed to parse property '8301_0'
2025-10-31T16:09:51.917Z:WARNING:web_functionalit:48:Failed to parse property '8302_0'
2025-10-31T16:09:52.039Z:WARNING:web_functionalit:48:Failed to parse property '8303_0'
2025-10-31T16:09:52.050Z:WARNING:web_functionalit:48:Failed to parse property '8101_1'
2025-10-31T16:09:52.058Z:WARNING:web_functionalit:48:Failed to parse property '8101_2'
2025-10-31T16:09:52.074Z:WARNING:web_functionalit:48:Failed to parse property '8102_1'
2025-10-31T16:09:52.082Z:WARNING:web_functionalit:48:Failed to parse property '8102_2'
2025-10-31T16:09:52.093Z:WARNING:web_functionalit:48:Failed to parse property '8103_1'
2025-10-31T16:09:52.101Z:WARNING:web_functionalit:48:Failed to parse property '8103_2'
2025-10-31T16:09:52.109Z:WARNING:web_functionalit:48:Failed to parse property '8108_1'
2025-10-31T16:09:52.121Z:WARNING:web_functionalit:48:Failed to parse property '8108_2'
2025-10-31T16:09:52.128Z:WARNING:web_functionalit:48:Failed to parse property '8107_1'
2025-10-31T16:09:52.136Z:WARNING:web_functionalit:48:Failed to parse property '8107_2'
2025-10-31T16:09:52.148Z:WARNING:web_functionalit:48:Failed to parse property '810A_1'
2025-10-31T16:09:52.156Z:WARNING:web_functionalit:48:Failed to parse property '810A_2'
2025-10-31T16:09:52.167Z:WARNING:web_functionalit:48:Failed to parse property '8109_1'
2025-10-31T16:09:52.175Z:WARNING:web_functionalit:48:Failed to parse property '8109_2'
2025-10-31T16:09:52.300Z:WARNING:web_functionalit:48:Failed to parse property '2188_0'
2025-10-31T16:10:14.593Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-31T16:10:14.921Z:WARNING:web_functionalit:48:Failed to parse property '2068_1'
2025-10-31T16:10:14.929Z:WARNING:web_functionalit:48:Failed to parse property '2068_2'
2025-10-31T16:10:14.941Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-10-31T16:10:15.355Z:WARNING:web_functionalit:48:Failed to parse property '8006_0'
2025-10-31T16:10:15.515Z:WARNING:web_functionalit:48:Failed to parse property '8201_0'
2025-10-31T16:10:15.527Z:WARNING:web_functionalit:48:Failed to parse property '8202_0'
2025-10-31T16:10:15.535Z:WARNING:web_functionalit:48:Failed to parse property '8203_0'
2025-10-31T16:10:15.542Z:WARNING:web_functionalit:48:Failed to parse property '8301_0'
2025-10-31T16:10:15.554Z:WARNING:web_functionalit:48:Failed to parse property '8302_0'
2025-10-31T16:10:15.707Z:WARNING:web_functionalit:48:Failed to parse property '8303_0'
2025-10-31T16:10:15.714Z:WARNING:web_functionalit:48:Failed to parse property '8101_1'
2025-10-31T16:10:15.722Z:WARNING:web_functionalit:48:Failed to parse property '8101_2'
2025-10-31T16:10:15.734Z:WARNING:web_functionalit:48:Failed to parse property '8102_1'
2025-10-31T16:10:15.742Z:WARNING:web_functionalit:48:Failed to parse property '8102_2'
2025-10-31T16:10:15.750Z:WARNING:web_functionalit:48:Failed to parse property '8103_1'
2025-10-31T16:10:15.761Z:WARNING:web_functionalit:48:Failed to parse property '8103_2'
2025-10-31T16:10:15.769Z:WARNING:web_functionalit:48:Failed to parse property '8108_1'
2025-10-31T16:10:15.781Z:WARNING:web_functionalit:48:Failed to parse property '8108_2'
2025-10-31T16:10:15.789Z:WARNING:web_functionalit:48:Failed to parse property '8107_1'
2025-10-31T16:10:15.796Z:WARNING:web_functionalit:48:Failed to parse property '8107_2'
2025-10-31T16:10:15.808Z:WARNING:web_functionalit:48:Failed to parse property '810A_1'
2025-10-31T16:10:15.816Z:WARNING:web_functionalit:48:Failed to parse property '810A_2'
2025-10-31T16:10:15.828Z:WARNING:web_functionalit:48:Failed to parse property '8109_1'
2025-10-31T16:10:15.835Z:WARNING:web_functionalit:48:Failed to parse property '8109_2'
2025-10-31T16:10:16.000Z:WARNING:web_functionalit:48:Failed to parse property '2188_0'
2025-10-31T16:10:34.792Z:INFO:web_functionali:159:Executing command: 'reboot'
2025-10-31T16:10:34.851Z:SECURITY:application.c:792:reset: requested, going down..
2025-10-31T16:10:46.953Z:RESET:application.c:414:==========================================
2025-10-31T16:10:46.964Z:INFO:application.c:421:build: May 28 2025 07:33:28
2025-10-31T16:10:46.972Z:INFO:application.c:422:version: 7.2.0-4362
2025-10-31T16:10:46.980Z:INFO:application.c:423:compiler: gcc 9.3.1
2025-10-31T16:10:46.984Z:INFO:application.c:285:fwu state inactive
2025-10-31T16:10:46.992Z:INFO:application.c:292:Bootloader version 2.2.2
2025-10-31T16:10:47.402Z:USER:taskCANopen.c:241:Persistent configuration retrieved, 282 items
2025-10-31T16:10:47.417Z:INFO:application.c:328:FLASH read protection 0xcc level 2 (permanent)
2025-10-31T16:10:47.425Z:USER:application.c:470:Using P1 port
2025-10-31T16:10:47.433Z:INFO:application.c:364:System boot #8, cause Software reset
2025-10-31T16:10:47.441Z:INFO:board_ng9xx.c:1649:Registered timeout getHardware
2025-10-31T16:10:49.152Z:INFO:bspMotors.c:616:Socket #1: Timeout while waiting for Cover motor
2025-10-31T16:10:50.261Z:INFO:board_ng9xx.c:5628:Socket 1: emergency relays check OK
2025-10-31T16:10:50.769Z:INFO:board_ng9xx.c:1676:Unregistered timeout getHardware
2025-10-31T16:10:50.777Z:INFO:application.c:510:ST MCU ID......................20036419
2025-10-31T16:10:50.789Z:INFO:application.c:511:Device ID:.....................004000203531510532353530
2025-10-31T16:10:50.796Z:INFO:application.c:512:Object ID:.....................ACE0640314
2025-10-31T16:10:50.808Z:INFO:application.c:513:#Sockets.......................1
2025-10-31T16:10:50.816Z:INFO:application.c:514:MAC address eeprom.............not available
2025-10-31T16:10:50.824Z:INFO:application.c:515:Configuration eeprom...........available
2025-10-31T16:10:50.835Z:INFO:application.c:517:Flash EEPROM...................available: manuf. 0x00c2, id 0x2016 (8 MB)
2025-10-31T16:10:50.847Z:INFO:application.c:520:Temperature sensor.............available (19.5/43.1 °C)
2025-10-31T16:10:50.859Z:INFO:application.c:521:Accelerometer/tilt sensor......not available
2025-10-31T16:10:50.867Z:INFO:application.c:522:Ambient light/proximity sensor.not available
2025-10-31T16:10:50.878Z:INFO:application.c:523:Real time clock................available
2025-10-31T16:10:50.886Z:INFO:application.c:524:Mobile network modem...........Autodetect (enabled)
2025-10-31T16:10:50.898Z:INFO:application.c:525:Ethernet PHY...................available
2025-10-31T16:10:51.105Z:INFO:application.c:534:#1 Control Pilot circuit.......available (0.2/-11.7 Volts)
2025-10-31T16:10:51.117Z:INFO:application.c:535:#1 Proximity Pin circuit.......available (100000 Ohms)
2025-10-31T16:10:51.125Z:INFO:application.c:536:#1 Socket motor................available
2025-10-31T16:10:51.136Z:INFO:application.c:537:#1 Cover motor.................not available
2025-10-31T16:10:51.144Z:INFO:application.c:538:#1 Auxiliary I/O...............not available
2025-10-31T16:10:51.156Z:INFO:application.c:539:#1 Button input................not available
2025-10-31T16:10:51.164Z:INFO:application.c:540:#1 NFC reader..................not available
2025-10-31T16:10:51.175Z:INFO:application.c:541:#1 Emergency relays............available
2025-10-31T16:10:51.183Z:INFO:application.c:560:-12V power supply..............available
2025-10-31T16:10:51.191Z:INFO:application.c:561:Smart meter P1 port interface..available
2025-10-31T16:10:51.203Z:INFO:application.c:562:Smart meter Suspend input......not available
2025-10-31T16:10:51.210Z:INFO:application.c:563:Smart meter external Modbus....available
2025-10-31T16:10:51.222Z:INFO:application.c:564:Energy meter ModBus interface..available
2025-10-31T16:10:51.230Z:INFO:application.c:565:Display user interface.........available
2025-10-31T16:10:51.238Z:INFO:application.c:566:PWM Buzzer.....................not available
2025-10-31T16:10:51.250Z:INFO:application.c:569:Auxiliary Board................supported
2025-10-31T16:10:51.257Z:INFO:application.c:570:Auxiliary Board revision.......D
2025-10-31T16:10:51.269Z:INFO:application.c:572:Powerboard revision/assy.......GUNKNOWN (32.0A)
2025-10-31T16:10:51.277Z:INFO:application.c:573:Controllerboard revision/assy..L7
2025-10-31T16:10:51.285Z:INFO:application.c:574:Powerboard relay type..........LATCHING_REVERSED
2025-10-31T16:10:51.296Z:INFO:application.c:592:Operational time ..............0D 00H
2025-10-31T16:10:51.308Z:INFO:db_common.c:147:Initializing all databases..
2025-10-31T16:10:51.746Z:INFO:db_base.c:1325:Initialized Transaction db (firstItem=0x00000000, lastItem=0x00001877)
2025-10-31T16:10:51.761Z:INFO:db_base.c:1325:Initialized LocalList db (firstItem=0x00000000, lastItem=0x00000000)
2025-10-31T16:10:51.777Z:INFO:db_base.c:1325:Initialized WhiteList db (firstItem=0x00000000, lastItem=0x00000041)
2025-10-31T16:10:51.792Z:INFO:db_base.c:1325:Initialized ChargingProfile db (firstItem=0x00000000, lastItem=0x000001b1)
2025-10-31T16:10:51.824Z:INFO:db_chargingprofi:75:Defragmented (#0/0, 19ms)
2025-10-31T16:10:51.832Z:INFO:db_chargingprofi:19:Max 45 charging profiles of 100 periods
2025-10-31T16:10:51.843Z:INFO:db_base.c:1325:Initialized Domain db (firstItem=0x00000000, lastItem=0x00000070)
2025-10-31T16:10:51.859Z:USER:ocpp.c:187:Init OCPP for ocpp1.6
2025-10-31T16:10:51.867Z:INFO:board_ng9xx.c:1649:Registered timeout BootNotification
2025-10-31T16:10:51.902Z:INFO:featureKeys.c:75:Unlocked Features: SCN,RFID-reader,4G (80010101)
2025-10-31T16:10:51.914Z:INFO:taskMain.c:604:Socket #1: Authorisation method COM unit via CAN
2025-10-31T16:10:51.921Z:INFO:taskMain.c:607:Socket #1: SocketType Mennekes
2025-10-31T16:10:51.929Z:INFO:taskMain.c:611:Socket #1: startup delay 5 s
2025-10-31T16:10:51.941Z:INFO:board_ng9xx.c:1649:Registered timeout NUVVE
2025-10-31T16:10:51.949Z:INFO:board_ng9xx.c:1649:Registered timeout NUVVE
2025-10-31T16:10:51.964Z:USER:EVsimulator.c:210:EV simulator initialised
2025-10-31T16:10:51.972Z:USER:taskMaster.c:1017:ocpp1.6 Smart Charging Mode
2025-10-31T16:10:52.187Z:INFO:bspEthernet.c:165:Ethernet PHY LAN8710@0x00
2025-10-31T16:10:52.203Z:INFO:taskMain.c:1299:charging_triac_starttime: 5
2025-10-31T16:10:52.210Z:INFO:taskMain.c:1300:charging_triac_keeptime : 50
2025-10-31T16:10:52.218Z:INFO:taskMain.c:1301:contactorstabletime : 50
2025-10-31T16:10:52.226Z:INFO:taskMain.c:1302:HFContactorSwitchTime : 60
2025-10-31T16:10:52.234Z:USER:bspEthernet.c:238:ETH PHY OK
2025-10-31T16:10:52.242Z:INFO:bspEthernet.c:217:MACAddress: [26:64:44:07:10:35]
2025-10-31T16:10:52.250Z:INFO:taskMain.c:6416:Socket #1: DSC initialised
2025-10-31T16:10:52.265Z:INFO:station.c:184:Active station current set to 25.0A max
2025-10-31T16:10:52.273Z:INFO:taskMain.c:6740:Socket #1: PP 34464 Ohm (0 A)
2025-10-31T16:10:52.281Z:INFO:taskMain.c:6746:Socket #1: PWM DC 10.0% (6.0 A)
2025-10-31T16:10:52.292Z:INFO:scn.c:686:Loadbalancing: Feature enabled
2025-10-31T16:10:52.300Z:INFO:scn.c:687:SCN: Feature enabled [Off]
2025-10-31T16:10:52.308Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-10-31T16:10:52.316Z:WARNING:scn_communicatio:75:SCN: Not enough sockets for an SCN!
2025-10-31T16:10:52.328Z:INFO:modem.c:1127:Modem state Idle->InitHw
2025-10-31T16:10:52.335Z:INFO:taskMeter.c:318:Starting smartmeter with protocol P1
2025-10-31T16:10:52.343Z:INFO:comConnect.c:295:Connectivity state: STARTUP
2025-10-31T16:10:52.351Z:INFO:taskModbus.c:4521:Address #1: modbus meter vendor : ALF
2025-10-31T16:10:52.363Z:INFO:taskModbus.c:4522:Address #1: modbus meter model : D3001
2025-10-31T16:10:52.371Z:INFO:taskModbus.c:4523:Address #1: modbus meter revision : V1.03
2025-10-31T16:10:52.382Z:INFO:taskModbus.c:4524:Address #1: modbus meter meterNumber : 22391493
2025-10-31T16:10:52.394Z:USER:taskModbus.c:933:Socket_1 Meter(1): meter type DZG_REALLIN found
2025-10-31T16:10:52.402Z:INFO:taskLeds.c:226:LED UI initialized OK
2025-10-31T16:10:52.894Z:USER:taskModbus.c:1104:Socket_1 Meter(1): first meter update, Multiple phase installation
2025-10-31T16:10:52.996Z:USER:taskMaster.c:1296:Node #1, version 7.2.0-4362
2025-10-31T16:10:53.195Z:INFO:taskNFCreader.c:579:Port #0 switch NFC power on
2025-10-31T16:10:53.210Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-31T16:10:53.218Z:INFO:taskCANopen.c:1200:Persistent memory not cached
2025-10-31T16:10:53.292Z:INFO:taskMain.c:1426:Socket #1: main state: BOOTING, CP: 0.0/0.0, no tag
2025-10-31T16:10:53.320Z:INFO:taskCANopen.c:2008:CanOpen EEPROM cache size: 282, got 282 objects <282,0>
2025-10-31T16:10:53.351Z:INFO:taskCANopen.c:1775:Updated object 0x2056, 4 bytes
2025-10-31T16:10:53.976Z:USER:bspEthernet.c:342:Mode: 100Mb/s full duplex
2025-10-31T16:10:53.988Z:INFO:taskTCPIP.c:953:Network Cable is now connected
2025-10-31T16:10:54.750Z:INFO:taskTCPIP.c:1577: IP address assigned by DHCP
2025-10-31T16:10:54.757Z:INFO:taskTCPIP.c:1605:Network interface is up
2025-10-31T16:10:54.765Z:INFO:taskTCPIP.c:1614: IP : 192.168.178.184
2025-10-31T16:10:54.773Z:INFO:taskTCPIP.c:1615: Netmask : 255.255.255.0
2025-10-31T16:10:54.781Z:INFO:taskTCPIP.c:1616: Gateway : 192.168.178.1
2025-10-31T16:10:54.789Z:INFO:taskTCPIP.c:1617: DNS1 : 192.168.178.1
2025-10-31T16:10:54.796Z:INFO:taskTCPIP.c:1618: DNS2 : 208.67.220.220
2025-10-31T16:10:54.804Z:INFO:taskTCPIP.c:512:Starting mDNS on interface al
2025-10-31T16:10:54.812Z:INFO:taskTCPIP.c:512:Starting Webserver on interface al
2025-10-31T16:10:54.824Z:INFO:taskTCPIP.c:512:Starting Modbus on interface al
2025-10-31T16:10:54.832Z:INFO:taskTCPIP.c:512:Starting P1 on interface al
2025-10-31T16:10:54.839Z:INFO:taskTCPIP.c:512:Starting SCN on interface al
2025-10-31T16:10:54.847Z:INFO:taskTCPIP.c:413:default network set to 'al'
2025-10-31T16:10:54.855Z:INFO:taskWebServer.c:238:WebServer state WAIT_FOR_NETWORK -> SETUP
2025-10-31T16:10:54.890Z:USER:taskWebServer.c:360:WebServer started on port 443
2025-10-31T16:10:54.898Z:INFO:taskWebServer.c:238:WebServer state SETUP -> AVAILABLE
2025-10-31T16:10:57.210Z:INFO:comConnect.c:1106:Connecting wired to: ws://192.168.178.140:8080/steve/websocket/CentralSystemServ
2025-10-31T16:10:57.210Z:INFO:comConnect.c:1106:ice/VAN_01971, prio #1
2025-10-31T16:10:57.281Z:INFO:comConnect.c:663:connection attempt 1/3
2025-10-31T16:10:57.308Z:INFO:comConnect.c:295:Connectivity state: INITIALISING
2025-10-31T16:10:57.320Z:INFO:taskNFCreader.c:115:Port #0 version response: "ICU NFC 243B (v3) v3.1-531"
2025-10-31T16:10:57.328Z:INFO:comConnect.c:295:Connectivity state: WIRED
2025-10-31T16:10:57.335Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:10:57.347Z:INFO:taskTCPIP.c:1486:'al' is configured as default internet connection.
2025-10-31T16:10:57.355Z:INFO:taskTCPIP.c:1503:Renew DHCP leash for interface 'al'.
2025-10-31T16:10:57.367Z:USER:comConnect.c:383:wired connect
2025-10-31T16:10:57.375Z:INFO:websockets.c:451:Connected to Socket 192.168.178.140:8080
2025-10-31T16:10:57.386Z:INFO:websockets.c:2363:WS timeout: 10000 ms
2025-10-31T16:10:57.433Z:INFO:websockets.c:824:WebSocket upgrade successful
2025-10-31T16:10:57.480Z:USER:taskOCPP.c:464:Back office connection available
2025-10-31T16:10:57.511Z:INFO:taskNFCreader.c:131:Port #0 ICU NFC reader BL3 v3.1, 1 LEDs
2025-10-31T16:10:57.550Z:INFO:taskNFCreader.c:132:Port #0 reader model: Giro-e
2025-10-31T16:10:57.617Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-31T16:10:57.832Z:USER:application.c:718:Initialisation done
2025-10-31T16:10:59.011Z:INFO:taskMaster.c:1104:Socket #1 has a Modbus meter
2025-10-31T16:10:59.019Z:INFO:updatefirmware.c:52:BL FWU_STATUS_INACTIVE -> int IDLE
2025-10-31T16:10:59.027Z:INFO:taskMain.c:1737:Socket #1: recovered INOPERATIVE
2025-10-31T16:10:59.035Z:USER:taskMaster.c:1131:1 NFC readers found
2025-10-31T16:10:59.058Z:INFO:taskMaster.c:1542:Socket #1: no open transaction
2025-10-31T16:10:59.082Z:INFO:smartMeter.c:80:Set phases: (L1, L2, L3)->(L1, L2, L3)
2025-10-31T16:10:59.089Z:INFO:active_lb.c:308:SMt:(0.0 0.0 0.0)A Free:(25.0 25.0 25.0)A ALB:(0.0 0.0 0.0)A
2025-10-31T16:10:59.101Z:INFO:taskMaster.c:4875:Socket #1: state main : INOPERATIVE
2025-10-31T16:10:59.109Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_OFF_BYPASS_OFF
2025-10-31T16:10:59.121Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_E
2025-10-31T16:10:59.128Z:INFO:taskMaster.c:4897:Socket #1: state led : CHECK_MAINS
2025-10-31T16:10:59.187Z:INFO:taskMaster.c:6294:Socket #1: no schedule
2025-10-31T16:10:59.195Z:USER:taskMaster.c:6318:Socket #1: external current limit 16.0 A
2025-10-31T16:10:59.207Z:INFO:station.c:97:station external max - new value: 99.9A
2025-10-31T16:10:59.214Z:INFO:comFaults.c:482:Reset fault status
2025-10-31T16:10:59.222Z:USER:taskMaster.c:1326:NFC version: ICU NFC 243B (v3) v3.1-531
2025-10-31T16:10:59.238Z:INFO:taskMaster.c:4897:Socket #1: state led : INOPERATIVE
2025-10-31T16:10:59.632Z:INFO:modem.c:1127:Modem state InitHw->InitModem
2025-10-31T16:10:59.640Z:INFO:modem.c:1299:Reset delay 2s
2025-10-31T16:11:00.152Z:INFO:taskMain.c:1426:Socket #1: main state: INOPERATIVE, CP: 0.0/0.0, no tag
2025-10-31T16:11:02.515Z:COM:ocpp_rpc.c:715:-> [2,"1","BootNotification",{"chargePointVendor":"Alfen BV","chargePointModel":
2025-10-31T16:11:02.515Z:COM:ocpp_rpc.c:715:"NG910-60583","chargePointSerialNumber":"ACE0640314","chargeBoxSerialNumber":"VA
2025-10-31T16:11:02.515Z:COM:ocpp_rpc.c:715:N_01971","firmwareVersion":"7.2.0-4362"}]
2025-10-31T16:11:02.578Z:COM:ocpp_rpc.c:1292:<- [3,"1",{"status":"Accepted","currentTime":"2025-10-31T16:11:03.294Z","interva
2025-10-31T16:11:02.578Z:COM:ocpp_rpc.c:1292:l":14400}]
2025-10-31T16:11:03.839Z:USER:modem.c:3614:Modem type: Quectel BG95-M3
2025-10-31T16:11:03.855Z:INFO:modem.c:3093:Check if modem responds
2025-10-31T16:11:03.894Z:INFO:modem.c:2980:Set flow control (on)
2025-10-31T16:11:04.066Z:INFO:modem.c:3133:Set type of logging
2025-10-31T16:11:09.285Z:INFO:comFaults.c:1075:#phases: socket #1 ''->'L1L2L3'
2025-10-31T16:11:11.410Z:SECURITY:comFaults.c:286:Going down
2025-10-31T16:11:11.433Z:INFO:taskMaster.c:4875:Socket #1: state main : ERROR_LOW_SUPPLY_VOLTAGE
2025-10-31T16:11:11.445Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_F
2025-10-31T16:11:11.453Z:INFO:taskMaster.c:4897:Socket #1: state led : ERROR_LOW_SUPPLY_VOLTAGE
2025-10-31T16:11:30.359Z:RESET:application.c:414:==========================================
2025-10-31T16:11:30.371Z:INFO:application.c:421:build: May 28 2025 07:33:28
2025-10-31T16:11:30.378Z:INFO:application.c:422:version: 7.2.0-4362
2025-10-31T16:11:30.386Z:INFO:application.c:423:compiler: gcc 9.3.1
2025-10-31T16:11:30.394Z:INFO:application.c:285:fwu state inactive
2025-10-31T16:11:30.402Z:INFO:application.c:292:Bootloader version 2.2.2
2025-10-31T16:11:30.808Z:USER:taskCANopen.c:241:Persistent configuration retrieved, 282 items
2025-10-31T16:11:30.824Z:INFO:application.c:328:FLASH read protection 0xcc level 2 (permanent)
2025-10-31T16:11:30.835Z:USER:application.c:470:Using P1 port
2025-10-31T16:11:30.839Z:INFO:application.c:364:System boot #9, cause Power on reset
2025-10-31T16:11:30.851Z:INFO:board_ng9xx.c:1649:Registered timeout getHardware
2025-10-31T16:11:32.558Z:INFO:bspMotors.c:616:Socket #1: Timeout while waiting for Cover motor
2025-10-31T16:11:33.667Z:INFO:board_ng9xx.c:5628:Socket 1: emergency relays check OK
2025-10-31T16:11:34.175Z:INFO:board_ng9xx.c:1676:Unregistered timeout getHardware
2025-10-31T16:11:34.183Z:INFO:application.c:510:ST MCU ID......................20036419
2025-10-31T16:11:34.195Z:INFO:application.c:511:Device ID:.....................004000203531510532353530
2025-10-31T16:11:34.203Z:INFO:application.c:512:Object ID:.....................ACE0640314
2025-10-31T16:11:34.214Z:INFO:application.c:513:#Sockets.......................1
2025-10-31T16:11:34.222Z:INFO:application.c:514:MAC address eeprom.............not available
2025-10-31T16:11:34.230Z:INFO:application.c:515:Configuration eeprom...........available
2025-10-31T16:11:34.242Z:INFO:application.c:517:Flash EEPROM...................available: manuf. 0x00c2, id 0x2016 (8 MB)
2025-10-31T16:11:34.253Z:INFO:application.c:520:Temperature sensor.............available (19.5/43.1 °C)
2025-10-31T16:11:34.265Z:INFO:application.c:521:Accelerometer/tilt sensor......not available
2025-10-31T16:11:34.273Z:INFO:application.c:522:Ambient light/proximity sensor.not available
2025-10-31T16:11:34.285Z:INFO:application.c:523:Real time clock................available
2025-10-31T16:11:34.292Z:INFO:application.c:524:Mobile network modem...........Autodetect (enabled)
2025-10-31T16:11:34.304Z:INFO:application.c:525:Ethernet PHY...................available
2025-10-31T16:11:34.511Z:INFO:application.c:534:#1 Control Pilot circuit.......available (0.2/-11.7 Volts)
2025-10-31T16:11:34.523Z:INFO:application.c:535:#1 Proximity Pin circuit.......available (100000 Ohms)
2025-10-31T16:11:34.535Z:INFO:application.c:536:#1 Socket motor................available
2025-10-31T16:11:34.542Z:INFO:application.c:537:#1 Cover motor.................not available
2025-10-31T16:11:34.550Z:INFO:application.c:538:#1 Auxiliary I/O...............not available
2025-10-31T16:11:34.562Z:INFO:application.c:539:#1 Button input................not available
2025-10-31T16:11:34.570Z:INFO:application.c:540:#1 NFC reader..................not available
2025-10-31T16:11:34.582Z:INFO:application.c:541:#1 Emergency relays............available
2025-10-31T16:11:34.589Z:INFO:application.c:560:-12V power supply..............available
2025-10-31T16:11:34.601Z:INFO:application.c:561:Smart meter P1 port interface..available
2025-10-31T16:11:34.609Z:INFO:application.c:562:Smart meter Suspend input......not available
2025-10-31T16:11:34.617Z:INFO:application.c:563:Smart meter external Modbus....available
2025-10-31T16:11:34.628Z:INFO:application.c:564:Energy meter ModBus interface..available
2025-10-31T16:11:34.636Z:INFO:application.c:565:Display user interface.........available
2025-10-31T16:11:34.648Z:INFO:application.c:566:PWM Buzzer.....................not available
2025-10-31T16:11:34.656Z:INFO:application.c:569:Auxiliary Board................supported
2025-10-31T16:11:34.664Z:INFO:application.c:570:Auxiliary Board revision.......D
2025-10-31T16:11:34.675Z:INFO:application.c:572:Powerboard revision/assy.......GUNKNOWN (32.0A)
2025-10-31T16:11:34.683Z:INFO:application.c:573:Controllerboard revision/assy..L7
2025-10-31T16:11:34.691Z:INFO:application.c:574:Powerboard relay type..........LATCHING_REVERSED
2025-10-31T16:11:34.703Z:INFO:application.c:592:Operational time ..............0D 00H
2025-10-31T16:11:34.718Z:INFO:db_common.c:147:Initializing all databases..
2025-10-31T16:11:35.140Z:INFO:db_base.c:1325:Initialized Transaction db (firstItem=0x00000000, lastItem=0x00001877)
2025-10-31T16:11:35.156Z:INFO:db_base.c:1325:Initialized LocalList db (firstItem=0x00000000, lastItem=0x00000000)
2025-10-31T16:11:35.167Z:INFO:db_base.c:1325:Initialized WhiteList db (firstItem=0x00000000, lastItem=0x00000041)
2025-10-31T16:11:35.187Z:INFO:db_base.c:1325:Initialized ChargingProfile db (firstItem=0x00000000, lastItem=0x000001b1)
2025-10-31T16:11:35.218Z:INFO:db_chargingprofi:75:Defragmented (#0/0, 19ms)
2025-10-31T16:11:35.226Z:INFO:db_chargingprofi:19:Max 45 charging profiles of 100 periods
2025-10-31T16:11:35.234Z:INFO:db_base.c:1325:Initialized Domain db (firstItem=0x00000000, lastItem=0x00000070)
2025-10-31T16:11:35.250Z:USER:ocpp.c:187:Init OCPP for ocpp1.6
2025-10-31T16:11:35.257Z:INFO:board_ng9xx.c:1649:Registered timeout BootNotification
2025-10-31T16:11:35.292Z:INFO:featureKeys.c:75:Unlocked Features: SCN,RFID-reader,4G (80010101)
2025-10-31T16:11:35.304Z:INFO:taskMain.c:604:Socket #1: Authorisation method COM unit via CAN
2025-10-31T16:11:35.316Z:INFO:taskMain.c:607:Socket #1: SocketType Mennekes
2025-10-31T16:11:35.324Z:INFO:taskMain.c:611:Socket #1: startup delay 5 s
2025-10-31T16:11:35.332Z:INFO:board_ng9xx.c:1649:Registered timeout NUVVE
2025-10-31T16:11:35.343Z:INFO:board_ng9xx.c:1649:Registered timeout NUVVE
2025-10-31T16:11:35.359Z:USER:EVsimulator.c:210:EV simulator initialised
2025-10-31T16:11:35.367Z:USER:taskMaster.c:1017:ocpp1.6 Smart Charging Mode
2025-10-31T16:11:35.578Z:INFO:bspEthernet.c:165:Ethernet PHY LAN8710@0x00
2025-10-31T16:11:35.593Z:INFO:taskMain.c:1299:charging_triac_starttime: 5
2025-10-31T16:11:35.601Z:INFO:taskMain.c:1300:charging_triac_keeptime : 50
2025-10-31T16:11:35.609Z:INFO:taskMain.c:1301:contactorstabletime : 50
2025-10-31T16:11:35.617Z:INFO:taskMain.c:1302:HFContactorSwitchTime : 60
2025-10-31T16:11:35.625Z:USER:bspEthernet.c:238:ETH PHY OK
2025-10-31T16:11:35.632Z:INFO:bspEthernet.c:217:MACAddress: [26:64:44:07:10:35]
2025-10-31T16:11:35.640Z:INFO:taskMain.c:6416:Socket #1: DSC initialised
2025-10-31T16:11:35.660Z:INFO:station.c:184:Active station current set to 25.0A max
2025-10-31T16:11:35.667Z:INFO:taskMain.c:6740:Socket #1: PP 34464 Ohm (0 A)
2025-10-31T16:11:35.675Z:INFO:taskMain.c:6746:Socket #1: PWM DC 10.0% (6.0 A)
2025-10-31T16:11:35.683Z:INFO:scn.c:686:Loadbalancing: Feature enabled
2025-10-31T16:11:35.691Z:INFO:scn.c:687:SCN: Feature enabled [Off]
2025-10-31T16:11:35.699Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-10-31T16:11:35.707Z:WARNING:scn_communicatio:75:SCN: Not enough sockets for an SCN!
2025-10-31T16:11:35.722Z:INFO:modem.c:1127:Modem state Idle->InitHw
2025-10-31T16:11:35.730Z:INFO:taskMeter.c:318:Starting smartmeter with protocol P1
2025-10-31T16:11:35.738Z:INFO:comConnect.c:295:Connectivity state: STARTUP
2025-10-31T16:11:35.746Z:INFO:taskModbus.c:4521:Address #1: modbus meter vendor : ALF
2025-10-31T16:11:35.753Z:INFO:taskModbus.c:4522:Address #1: modbus meter model : D3001
2025-10-31T16:11:35.765Z:INFO:taskModbus.c:4523:Address #1: modbus meter revision : V1.03
2025-10-31T16:11:35.777Z:INFO:taskModbus.c:4524:Address #1: modbus meter meterNumber : 22391493
2025-10-31T16:11:35.785Z:USER:taskModbus.c:933:Socket_1 Meter(1): meter type DZG_REALLIN found
2025-10-31T16:11:35.796Z:INFO:taskLeds.c:226:LED UI initialized OK
2025-10-31T16:11:36.281Z:USER:taskModbus.c:1104:Socket_1 Meter(1): first meter update, Multiple phase installation
2025-10-31T16:11:36.390Z:USER:taskMaster.c:1296:Node #1, version 7.2.0-4362
2025-10-31T16:11:36.589Z:INFO:taskNFCreader.c:579:Port #0 switch NFC power on
2025-10-31T16:11:36.601Z:INFO:taskCANopen.c:1195:Persistent memory hash changed
2025-10-31T16:11:36.609Z:INFO:taskCANopen.c:1200:Persistent memory not cached
2025-10-31T16:11:36.683Z:INFO:taskMain.c:1426:Socket #1: main state: BOOTING, CP: 0.0/0.0, no tag
2025-10-31T16:11:36.714Z:INFO:taskCANopen.c:2008:CanOpen EEPROM cache size: 282, got 282 objects <282,0>
2025-10-31T16:11:36.742Z:INFO:taskCANopen.c:1775:Updated object 0x2056, 4 bytes
2025-10-31T16:11:36.765Z:INFO:taskCANopen.c:1775:Updated object 0x2057, 51 bytes
2025-10-31T16:11:37.371Z:USER:bspEthernet.c:342:Mode: 100Mb/s full duplex
2025-10-31T16:11:37.378Z:INFO:taskTCPIP.c:953:Network Cable is now connected
2025-10-31T16:11:38.140Z:INFO:taskTCPIP.c:1577: IP address assigned by DHCP
2025-10-31T16:11:38.148Z:INFO:taskTCPIP.c:1605:Network interface is up
2025-10-31T16:11:38.156Z:INFO:taskTCPIP.c:1614: IP : 192.168.178.184
2025-10-31T16:11:38.164Z:INFO:taskTCPIP.c:1615: Netmask : 255.255.255.0
2025-10-31T16:11:38.171Z:INFO:taskTCPIP.c:1616: Gateway : 192.168.178.1
2025-10-31T16:11:38.179Z:INFO:taskTCPIP.c:1617: DNS1 : 192.168.178.1
2025-10-31T16:11:38.187Z:INFO:taskTCPIP.c:1618: DNS2 : 208.67.220.220
2025-10-31T16:11:38.199Z:INFO:taskTCPIP.c:512:Starting mDNS on interface al
2025-10-31T16:11:38.207Z:INFO:taskTCPIP.c:512:Starting Webserver on interface al
2025-10-31T16:11:38.214Z:INFO:taskTCPIP.c:512:Starting Modbus on interface al
2025-10-31T16:11:38.222Z:INFO:taskTCPIP.c:512:Starting P1 on interface al
2025-10-31T16:11:38.230Z:INFO:taskTCPIP.c:512:Starting SCN on interface al
2025-10-31T16:11:38.238Z:INFO:taskTCPIP.c:413:default network set to 'al'
2025-10-31T16:11:38.246Z:INFO:taskWebServer.c:238:WebServer state WAIT_FOR_NETWORK -> SETUP
2025-10-31T16:11:38.281Z:USER:taskWebServer.c:360:WebServer started on port 443
2025-10-31T16:11:38.289Z:INFO:taskWebServer.c:238:WebServer state SETUP -> AVAILABLE
2025-10-31T16:11:40.601Z:INFO:comConnect.c:1106:Connecting wired to: ws://192.168.178.140:8080/steve/websocket/CentralSystemServ
2025-10-31T16:11:40.601Z:INFO:comConnect.c:1106:ice/VAN_01971, prio #1
2025-10-31T16:11:40.628Z:INFO:comConnect.c:663:connection attempt 1/3
2025-10-31T16:11:40.636Z:INFO:comConnect.c:295:Connectivity state: INITIALISING
2025-10-31T16:11:40.644Z:INFO:taskNFCreader.c:115:Port #0 version response: "ICU NFC 243B (v3) v3.1-531"
2025-10-31T16:11:40.656Z:INFO:comConnect.c:295:Connectivity state: WIRED
2025-10-31T16:11:40.671Z:INFO:taskTCPIP.c:1486:'al' is configured as default internet connection.
2025-10-31T16:11:40.683Z:INFO:taskTCPIP.c:1503:Renew DHCP leash for interface 'al'.
2025-10-31T16:11:40.691Z:USER:comConnect.c:383:wired connect
2025-10-31T16:11:40.699Z:INFO:websockets.c:451:Connected to Socket 192.168.178.140:8080
2025-10-31T16:11:40.710Z:INFO:websockets.c:2363:WS timeout: 10000 ms
2025-10-31T16:11:40.750Z:INFO:websockets.c:824:WebSocket upgrade successful
2025-10-31T16:11:40.769Z:USER:taskOCPP.c:464:Back office connection available
2025-10-31T16:11:40.800Z:USER:application.c:718:Initialisation done
2025-10-31T16:11:40.808Z:INFO:taskNFCreader.c:131:Port #0 ICU NFC reader BL3 v3.1, 1 LEDs
2025-10-31T16:11:40.820Z:INFO:taskNFCreader.c:132:Port #0 reader model: Giro-e
2025-10-31T16:11:42.402Z:INFO:taskMaster.c:1104:Socket #1 has a Modbus meter
2025-10-31T16:11:42.414Z:INFO:updatefirmware.c:52:BL FWU_STATUS_INACTIVE -> int IDLE
2025-10-31T16:11:42.421Z:INFO:taskMain.c:1749:Socket #1: skip recover charging state by configuration
2025-10-31T16:11:42.433Z:USER:taskMaster.c:1131:1 NFC readers found
2025-10-31T16:11:42.464Z:INFO:taskMaster.c:1542:Socket #1: no open transaction
2025-10-31T16:11:42.484Z:INFO:smartMeter.c:80:Set phases: (L1, L2, L3)->(L1, L2, L3)
2025-10-31T16:11:42.496Z:INFO:active_lb.c:308:SMt:(0.0 0.0 0.0)A Free:(25.0 25.0 25.0)A ALB:(0.0 0.0 0.0)A
2025-10-31T16:11:42.507Z:INFO:taskMaster.c:4875:Socket #1: state main : AVAILABLE
2025-10-31T16:11:42.531Z:INFO:taskMain.c:6676:Socket #1: active tag cleared
2025-10-31T16:11:42.566Z:INFO:taskMaster.c:4883:Socket #1: state power : POWER_MAIN_OFF_BYPASS_OFF
2025-10-31T16:11:42.578Z:INFO:taskMaster.c:4890:Socket #1: state Mode-3: STATE_E
2025-10-31T16:11:42.585Z:INFO:taskMaster.c:4897:Socket #1: state led : AVAILABLE
2025-10-31T16:11:42.648Z:INFO:taskMaster.c:6294:Socket #1: no schedule
2025-10-31T16:11:42.656Z:USER:taskMaster.c:6318:Socket #1: external current limit 16.0 A
2025-10-31T16:11:42.664Z:INFO:station.c:97:station external max - new value: 99.9A
2025-10-31T16:11:42.671Z:INFO:comFaults.c:482:Reset fault status
2025-10-31T16:11:42.683Z:USER:taskMaster.c:1326:NFC version: ICU NFC 243B (v3) v3.1-531
2025-10-31T16:11:42.726Z:INFO:taskMaster.c:4875:Socket #1: state main : INOPERATIVE
2025-10-31T16:11:42.738Z:INFO:taskMaster.c:4897:Socket #1: state led : INOPERATIVE
2025-10-31T16:11:43.027Z:INFO:modem.c:1127:Modem state InitHw->InitModem
2025-10-31T16:11:43.035Z:INFO:modem.c:1299:Reset delay 2s
2025-10-31T16:11:43.714Z:INFO:taskMain.c:1426:Socket #1: main state: INOPERATIVE, CP: 0.0/0.0, no tag
2025-10-31T16:11:45.781Z:COM:ocpp_rpc.c:715:-> [2,"1","BootNotification",{"chargePointVendor":"Alfen BV","chargePointModel":
2025-10-31T16:11:45.781Z:COM:ocpp_rpc.c:715:"NG910-60583","chargePointSerialNumber":"ACE0640314","chargeBoxSerialNumber":"VA
2025-10-31T16:11:45.781Z:COM:ocpp_rpc.c:715:N_01971","firmwareVersion":"7.2.0-4362"}]
2025-10-31T16:11:45.851Z:COM:ocpp_rpc.c:1292:<- [3,"1",{"status":"Accepted","currentTime":"2025-10-31T16:11:46.560Z","interva
2025-10-31T16:11:45.851Z:COM:ocpp_rpc.c:1292:l":14400}]
2025-10-31T16:11:47.230Z:USER:modem.c:3614:Modem type: Quectel BG95-M3
2025-10-31T16:11:47.246Z:INFO:modem.c:3093:Check if modem responds
2025-10-31T16:11:47.285Z:INFO:modem.c:2980:Set flow control (on)
2025-10-31T16:11:47.457Z:INFO:modem.c:3133:Set type of logging
2025-10-31T16:11:52.726Z:INFO:comFaults.c:1075:#phases: socket #1 ''->'L1L2L3'
2025-10-31T16:11:55.945Z:COM:ocpp_rpc.c:715:-> [2,"2","StatusNotification",{"connectorId":0,"errorCode":"NoError","status":"
2025-10-31T16:11:55.945Z:COM:ocpp_rpc.c:715:Unavailable"}]
2025-10-31T16:11:55.988Z:COM:ocpp_rpc.c:1292:<- [3,"2",{}]
2025-10-31T16:11:55.996Z:COM:ocpp_rpc.c:715:-> [2,"3","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":"
2025-10-31T16:11:55.996Z:COM:ocpp_rpc.c:715:Unavailable"}]
2025-10-31T16:11:56.031Z:COM:ocpp_rpc.c:1292:<- [3,"3",{}]
2025-10-31T16:12:02.101Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:12:02.425Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-31T16:12:02.789Z:WARNING:web_functionalit:48:Failed to parse property '2068_1'
2025-10-31T16:12:02.796Z:WARNING:web_functionalit:48:Failed to parse property '2068_2'
2025-10-31T16:12:02.808Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-10-31T16:12:03.230Z:WARNING:web_functionalit:48:Failed to parse property '8006_0'
2025-10-31T16:12:03.382Z:WARNING:web_functionalit:48:Failed to parse property '8201_0'
2025-10-31T16:12:03.394Z:WARNING:web_functionalit:48:Failed to parse property '8202_0'
2025-10-31T16:12:03.402Z:WARNING:web_functionalit:48:Failed to parse property '8203_0'
2025-10-31T16:12:03.410Z:WARNING:web_functionalit:48:Failed to parse property '8301_0'
2025-10-31T16:12:03.421Z:WARNING:web_functionalit:48:Failed to parse property '8302_0'
2025-10-31T16:12:03.554Z:WARNING:web_functionalit:48:Failed to parse property '8303_0'
2025-10-31T16:12:03.562Z:WARNING:web_functionalit:48:Failed to parse property '8101_1'
2025-10-31T16:12:03.570Z:WARNING:web_functionalit:48:Failed to parse property '8101_2'
2025-10-31T16:12:03.582Z:WARNING:web_functionalit:48:Failed to parse property '8102_1'
2025-10-31T16:12:03.589Z:WARNING:web_functionalit:48:Failed to parse property '8102_2'
2025-10-31T16:12:03.597Z:WARNING:web_functionalit:48:Failed to parse property '8103_1'
2025-10-31T16:12:03.609Z:WARNING:web_functionalit:48:Failed to parse property '8103_2'
2025-10-31T16:12:03.617Z:WARNING:web_functionalit:48:Failed to parse property '8108_1'
2025-10-31T16:12:03.625Z:WARNING:web_functionalit:48:Failed to parse property '8108_2'
2025-10-31T16:12:03.636Z:WARNING:web_functionalit:48:Failed to parse property '8107_1'
2025-10-31T16:12:03.644Z:WARNING:web_functionalit:48:Failed to parse property '8107_2'
2025-10-31T16:12:03.656Z:WARNING:web_functionalit:48:Failed to parse property '810A_1'
2025-10-31T16:12:03.664Z:WARNING:web_functionalit:48:Failed to parse property '810A_2'
2025-10-31T16:12:03.671Z:WARNING:web_functionalit:48:Failed to parse property '8109_1'
2025-10-31T16:12:03.683Z:WARNING:web_functionalit:48:Failed to parse property '8109_2'
2025-10-31T16:12:03.886Z:WARNING:web_functionalit:48:Failed to parse property '2188_0'
2025-10-31T16:12:05.933Z:INFO:modem.c:2528:Check PIN
2025-10-31T16:12:09.707Z:WARNING:modem.c:2565:SIM error
2025-10-31T16:12:11.808Z:INFO:taskWifi.c:657:WiFi Module: Not Initialized --> Running
2025-10-31T16:12:13.378Z:INFO:wifi.c:451:Successfully started AP <ACE0640314> ip<192.168.1.1>
2025-10-31T16:12:13.386Z:INFO:taskWifi.c:928:Start WiFi AP
2025-10-31T16:12:13.394Z:WARNING:taskWifi.c:1007:Wifi config is not valid
2025-10-31T16:12:13.402Z:INFO:taskWifi.c:664:SoftAP: Not Initialized --> Enabled
2025-10-31T16:12:13.410Z:INFO:taskWifi.c:671:STA: Not Initialized --> Not Configured
2025-10-31T16:12:13.582Z:WARNING:modem.c:2565:SIM error
2025-10-31T16:12:17.460Z:WARNING:modem.c:2565:SIM error
2025-10-31T16:12:21.339Z:WARNING:modem.c:2565:SIM error
2025-10-31T16:12:21.445Z:INFO:modem.c:2575:Check PIN failed
2025-10-31T16:12:22.496Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-31T16:12:22.753Z:WARNING:web_functionalit:48:Failed to parse property '2068_1'
2025-10-31T16:12:22.765Z:WARNING:web_functionalit:48:Failed to parse property '2068_2'
2025-10-31T16:12:22.777Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-10-31T16:12:23.226Z:WARNING:web_functionalit:48:Failed to parse property '8006_0'
2025-10-31T16:12:23.390Z:WARNING:web_functionalit:48:Failed to parse property '8201_0'
2025-10-31T16:12:23.398Z:WARNING:web_functionalit:48:Failed to parse property '8202_0'
2025-10-31T16:12:23.410Z:WARNING:web_functionalit:48:Failed to parse property '8203_0'
2025-10-31T16:12:23.417Z:WARNING:web_functionalit:48:Failed to parse property '8301_0'
2025-10-31T16:12:23.425Z:WARNING:web_functionalit:48:Failed to parse property '8302_0'
2025-10-31T16:12:23.550Z:WARNING:web_functionalit:48:Failed to parse property '8303_0'
2025-10-31T16:12:23.558Z:WARNING:web_functionalit:48:Failed to parse property '8101_1'
2025-10-31T16:12:23.566Z:WARNING:web_functionalit:48:Failed to parse property '8101_2'
2025-10-31T16:12:23.578Z:WARNING:web_functionalit:48:Failed to parse property '8102_1'
2025-10-31T16:12:23.585Z:WARNING:web_functionalit:48:Failed to parse property '8102_2'
2025-10-31T16:12:23.597Z:WARNING:web_functionalit:48:Failed to parse property '8103_1'
2025-10-31T16:12:23.605Z:WARNING:web_functionalit:48:Failed to parse property '8103_2'
2025-10-31T16:12:23.613Z:WARNING:web_functionalit:48:Failed to parse property '8108_1'
2025-10-31T16:12:23.625Z:WARNING:web_functionalit:48:Failed to parse property '8108_2'
2025-10-31T16:12:23.632Z:WARNING:web_functionalit:48:Failed to parse property '8107_1'
2025-10-31T16:12:23.640Z:WARNING:web_functionalit:48:Failed to parse property '8107_2'
2025-10-31T16:12:23.652Z:WARNING:web_functionalit:48:Failed to parse property '810A_1'
2025-10-31T16:12:23.660Z:WARNING:web_functionalit:48:Failed to parse property '810A_2'
2025-10-31T16:12:23.671Z:WARNING:web_functionalit:48:Failed to parse property '8109_1'
2025-10-31T16:12:23.679Z:WARNING:web_functionalit:48:Failed to parse property '8109_2'
2025-10-31T16:12:23.855Z:WARNING:web_functionalit:48:Failed to parse property '2188_0'
2025-10-31T16:12:36.269Z:INFO:modem.c:3294:Get other info
2025-10-31T16:13:06.023Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-10-31T16:13:06.035Z:WARNING:web_functionalit:48:Failed to parse property '2082_0'
2025-10-31T16:13:09.378Z:WARNING:modem.c:2728:AT+CSQ, invalid value(99)
2025-10-31T16:13:41.359Z:INFO:modem.c:3316:Signal strength : Unknown
2025-10-31T16:13:41.367Z:INFO:modem.c:3318:Radio Access Tech : 4G
2025-10-31T16:13:41.375Z:INFO:modem.c:3319:Registration mode : Disabled
2025-10-31T16:13:41.382Z:INFO:modem.c:3320:Registration status: Not registered
2025-10-31T16:13:41.390Z:INFO:modem.c:3321:Operator : 0
2025-10-31T16:13:41.398Z:INFO:modem.c:3322:Manufacturer : Quectel
2025-10-31T16:13:41.406Z:INFO:modem.c:3323:Modem module : BG95-M3
2025-10-31T16:13:41.414Z:INFO:modem.c:3324:Modem revision : BG95M3LAR02A03_01.012.01.012
2025-10-31T16:13:41.421Z:INFO:modem.c:3325:Modem IMEI : 864145067568848
2025-10-31T16:13:41.429Z:INFO:modem.c:3326:SIM IMSI :
2025-10-31T16:13:41.437Z:INFO:modem.c:3327:SIM ICCID :
2025-10-31T16:13:41.445Z:INFO:modem.c:3328:Modem supports 2G : yes
2025-10-31T16:13:41.453Z:INFO:modem.c:3329:Modem supports 3G : no
2025-10-31T16:13:41.460Z:INFO:modem.c:3330:Modem supports 4G : yes
2025-10-31T16:13:41.511Z:INFO:modem.c:3337:Cellinfo : "SEARCH"
2025-10-31T16:13:41.519Z:ERROR:modem.c:3367:Setup modem Failed
2025-10-31T16:13:41.527Z:INFO:modem.c:1127:Modem state InitModem->Stopping
2025-10-31T16:13:50.046Z:INFO:modem.c:1127:Modem state Stopping->Idle
2025-10-31T16:15:21.640Z:WARNING:taskWebClient.c:234:Client (fd=2) disconnected (r: -0x50)
2025-10-31T16:15:21.652Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-31T16:15:21.765Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-31T16:15:56.328Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:15:56.972Z:SECURITY:httpd_login.c:155:WebClient connected (account: admin)
2025-10-31T16:15:57.066Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-10-31T16:16:22.425Z:INFO:updatefirmware.:211:signature: PKCS1_PSS_SHA256_2048
2025-10-31T16:16:22.437Z:INFO:updatefirmware.:212:encryption: AES128
2025-10-31T16:16:22.445Z:SECURITY:updatefirmware.:226:UpdateFirmware file type: UPDATE_FIRMWARE_NG9xx_VERSION_01
2025-10-31T16:16:28.816Z:INFO:updatefirmware.:185:Firmware region erased
2025-10-31T16:16:38.800Z:USER:updatefirmware.:309:Download progress:
2025-10-31T16:16:38.808Z:USER:updatefirmware.:309: payload: 180832/1808144 [10%]
2025-10-31T16:16:48.789Z:USER:updatefirmware.:309:Download progress:
2025-10-31T16:16:48.796Z:USER:updatefirmware.:309: payload: 361824/1808144 [20%]
2025-10-31T16:16:58.765Z:USER:updatefirmware.:309:Download progress:
2025-10-31T16:16:58.773Z:USER:updatefirmware.:309: payload: 542560/1808144 [30%]
2025-10-31T16:17:08.757Z:USER:updatefirmware.:309:Download progress:
2025-10-31T16:17:08.765Z:USER:updatefirmware.:309: payload: 723296/1808144 [40%]
2025-10-31T16:17:18.742Z:USER:updatefirmware.:309:Download progress:
2025-10-31T16:17:18.750Z:USER:updatefirmware.:309: payload: 904288/1808144 [50%]
2025-10-31T16:17:28.707Z:USER:updatefirmware.:309:Download progress:
2025-10-31T16:17:28.714Z:USER:updatefirmware.:309: payload: 1085024/1808144 [60%]
2025-10-31T16:17:38.726Z:USER:updatefirmware.:309:Download progress:
2025-10-31T16:17:38.734Z:USER:updatefirmware.:309: payload: 1265760/1808144 [70%]
2025-10-31T16:17:48.722Z:USER:updatefirmware.:309:Download progress:
2025-10-31T16:17:48.730Z:USER:updatefirmware.:309: payload: 1446752/1808144 [80%]
2025-10-31T16:17:56.031Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 1 of max 10
2025-10-31T16:17:58.710Z:USER:updatefirmware.:309:Download progress:
2025-10-31T16:17:58.718Z:USER:updatefirmware.:309: payload: 1627488/1808144 [90%]
2025-10-31T16:18:08.691Z:USER:updatefirmware.:309:Download progress:
2025-10-31T16:18:08.699Z:USER:updatefirmware.:309: payload: 1808224/1808144 [100%]
2025-10-31T16:18:08.789Z:SECURITY:updatefirmware.c:71:FirmwareDownload done
2025-10-31T16:18:08.820Z:INFO:updatefirmware.:321:Fwi sig decode/verification "ok"
2025-10-31T16:18:08.828Z:COM:ocpp_rpc.c:715:-> [2,"4","FirmwareStatusNotification",{"status":"Downloaded"}]
2025-10-31T16:18:08.878Z:COM:ocpp_rpc.c:1292:<- [3,"4",{}]
2025-10-31T16:18:13.996Z:COM:ocpp_rpc.c:715:-> [2,"5","FirmwareStatusNotification",{"status":"Installing"}]
2025-10-31T16:18:14.039Z:COM:ocpp_rpc.c:1292:<- [3,"5",{}]
2025-10-31T16:18:19.832Z:INFO:taskCommandLine.:23:Executing: system(cansync off)
2025-10-31T16:18:19.839Z:CONSOLE:taskCommandLine.:43:cansync off
2025-10-31T16:18:19.843Z:SECURITY:application.c:792:reset: execute firmware update
2025-10-31T16:20:32.269Z:RESET:application.c:414:==========================================
2025-10-31T16:20:32.277Z:INFO:application.c:421:build: Oct 27 2025 13:58:28
2025-10-31T16:20:32.285Z:INFO:application.c:422:version: 7.3.0-4377
2025-10-31T16:20:32.292Z:INFO:application.c:423:compiler: gcc 9.3.1
2025-10-31T16:20:32.300Z:INFO:application.c:285:fwu state reboot
2025-10-31T16:20:32.308Z:INFO:application.c:292:Bootloader version 2.2.2
2025-10-31T16:20:32.714Z:USER:taskCANopen.c:241:Persistent configuration retrieved, 282 items
2025-10-31T16:20:32.730Z:INFO:application.c:328:FLASH read protection 0xcc level 2 (permanent)
2025-10-31T16:20:32.742Z:USER:application.c:470:Using P1 port
2025-10-31T16:20:32.746Z:INFO:application.c:364:System boot #10, cause Software reset
2025-10-31T16:20:32.757Z:INFO:board_ng9xx.c:1602:Registered timeout getHardware
2025-10-31T16:20:34.464Z:INFO:bspMotors.c:616:Socket #1: Timeout while waiting for Cover motor
2025-10-31T16:20:34.523Z:INFO:board_ng9xx.c:1629:Unregistered timeout getHardware
2025-10-31T16:20:34.531Z:INFO:application.c:510:ST MCU ID......................20036419
2025-10-31T16:20:34.542Z:INFO:application.c:511:Device ID:.....................004000203531510532353530
2025-10-31T16:20:34.550Z:INFO:application.c:512:Object ID:.....................ACE0640314
2025-10-31T16:20:34.562Z:INFO:application.c:513:#Sockets.......................1
2025-10-31T16:20:34.570Z:INFO:application.c:514:MAC address eeprom.............not available
2025-10-31T16:20:34.578Z:INFO:application.c:515:Configuration eeprom...........available
2025-10-31T16:20:34.589Z:INFO:application.c:517:Flash EEPROM...................available: manuf. 0x00c2, id 0x2016 (8 MB)
2025-10-31T16:20:34.601Z:INFO:application.c:520:Temperature sensor.............available (19.5/43.1 °C)
2025-10-31T16:20:34.613Z:INFO:application.c:521:Accelerometer/tilt sensor......not available
2025-10-31T16:20:34.621Z:INFO:application.c:522:Ambient light/proximity sensor.not available
2025-10-31T16:20:34.632Z:INFO:application.c:523:Real time clock................available
2025-10-31T16:20:34.640Z:INFO:application.c:524:Mobile network modem...........Autodetect (enabled)
2025-10-31T16:20:34.652Z:INFO:application.c:525:Ethernet PHY...................available
2025-10-31T16:20:34.859Z:INFO:application.c:534:#1 Control Pilot circuit.......available (0.2/-11.7 Volts)
2025-10-31T16:20:34.871Z:INFO:application.c:535:#1 Proximity Pin circuit.......available (100000 Ohms)
2025-10-31T16:20:34.882Z:INFO:application.c:536:#1 Socket motor................available
2025-10-31T16:20:34.890Z:INFO:application.c:537:#1 Cover motor.................not available
2025-10-31T16:20:34.902Z:INFO:application.c:538:#1 Auxiliary I/O...............not available
2025-10-31T16:20:34.910Z:INFO:application.c:539:#1 Button input................not available
2025-10-31T16:20:34.921Z:INFO:application.c:540:#1 NFC reader..................not available
2025-10-31T16:20:34.929Z:INFO:application.c:541:#1 Emergency relays............available
2025-10-31T16:20:34.937Z:INFO:application.c:560:-12V power supply..............available
2025-10-31T16:20:34.949Z:INFO:application.c:561:Smart meter P1 port interface..available
2025-10-31T16:20:34.957Z:INFO:application.c:562:Smart meter Suspend input......not available
2025-10-31T16:20:34.968Z:INFO:application.c:563:Smart meter external Modbus....available
2025-10-31T16:20:34.976Z:INFO:application.c:564:Energy meter ModBus interface..available
2025-10-31T16:20:34.984Z:INFO:application.c:565:Display user interface.........available
2025-10-31T16:20:34.996Z:INFO:application.c:566:PWM Buzzer.....................not available
2025-10-31T16:20:35.003Z:INFO:application.c:569:Auxiliary Board................supported
2025-10-31T16:20:35.015Z:INFO:application.c:570:Auxiliary Board revision.......D
2025-10-31T16:20:35.023Z:INFO:application.c:572:Powerboard revision/assy.......GUNKNOWN (32.0A)
2025-10-31T16:20:35.031Z:INFO:application.c:573:Controllerboard revision/assy..L7
2025-10-31T16:20:35.042Z:INFO:application.c:574:Powerboard relay type..........LATCHING_REVERSED
2025-10-31T16:20:35.050Z:INFO:application.c:592:Operational time ..............0D 00H
2025-10-31T16:20:35.066Z:INFO:db_common.c:147:Initializing all databases..
2025-10-31T16:20:35.480Z:INFO:db_base.c:1279:Disabled Transaction db due to firmware upgrade
2025-10-31T16:20:35.492Z:INFO:db_base.c:1279:Disabled LocalList db due to firmware upgrade
2025-10-31T16:20:35.503Z:INFO:db_base.c:1279:Disabled WhiteList db due to firmware upgrade
2025-10-31T16:20:35.515Z:INFO:db_base.c:1279:Disabled ChargingProfile db due to firmware upgrade
2025-10-31T16:20:35.523Z:INFO:db_chargingprofi:75:Defragmented (#0/0, 0ms)
2025-10-31T16:20:35.531Z:INFO:db_chargingprofi:19:Max 45 charging profiles of 100 periods
2025-10-31T16:20:35.542Z:INFO:db_base.c:1279:Disabled Domain db due to firmware upgrade
2025-10-31T16:20:35.558Z:USER:ocpp.c:187:Init OCPP for ocpp1.6
2025-10-31T16:20:35.562Z:INFO:board_ng9xx.c:1602:Registered timeout BootNotification
2025-10-31T16:20:35.601Z:INFO:featureKeys.c:78:Unlocked Features: SCN,RFID-reader,4G (80010101)
2025-10-31T16:20:35.609Z:INFO:taskMain.c:599:Socket #1: Authorisation method COM unit via CAN
2025-10-31T16:20:35.621Z:INFO:taskMain.c:602:Socket #1: SocketType Mennekes
2025-10-31T16:20:35.628Z:INFO:taskMain.c:606:Socket #1: startup delay 5 s
2025-10-31T16:20:35.640Z:WARNING:db_transaction.:258:Unexpected record @0x00000000
2025-10-31T16:20:35.652Z:INFO:board_ng9xx.c:1602:Registered timeout NUVVE
2025-10-31T16:20:35.660Z:INFO:board_ng9xx.c:1602:Registered timeout NUVVE
2025-10-31T16:20:35.679Z:USER:EVsimulator.c:210:EV simulator initialised
2025-10-31T16:20:35.687Z:USER:taskMaster.c:1050:ocpp1.6 Smart Charging Mode
2025-10-31T16:20:35.898Z:INFO:bspEthernet.c:165:Ethernet PHY LAN8710@0x00
2025-10-31T16:20:35.917Z:USER:bspEthernet.c:238:ETH PHY OK
2025-10-31T16:20:35.921Z:INFO:bspEthernet.c:217:MACAddress: [26:64:44:07:10:35]
2025-10-31T16:20:35.933Z:INFO:taskMeter.c:318:Starting smartmeter with protocol P1
2025-10-31T16:20:35.941Z:INFO:scn.c:686:Loadbalancing: Feature enabled
2025-10-31T16:20:35.949Z:INFO:scn.c:687:SCN: Feature enabled [Off]
2025-10-31T16:20:35.957Z:WARNING:scn_communicatio:75:SCN: Not enough sockets for an SCN!
2025-10-31T16:20:35.968Z:INFO:modem.c:1124:Modem state Idle->InitHw
2025-10-31T16:20:35.980Z:INFO:taskMain.c:1294:contactorstabletime : 50
2025-10-31T16:20:35.988Z:INFO:taskMain.c:1295:HFContactorSwitchTime : 60
2025-10-31T16:20:36.003Z:INFO:taskLeds.c:226:LED UI initialized OK
2025-10-31T16:20:36.011Z:INFO:taskMain.c:6180:Socket #1: DSC initialised
2025-10-31T16:20:36.019Z:INFO:station.c:184:Active station current set to 25.0A max
2025-10-31T16:20:36.039Z:INFO:taskMain.c:6504:Socket #1: PP 34464 Ohm (0 A)
2025-10-31T16:20:36.046Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.0% (6.0 A)
2025-10-31T16:20:36.054Z:INFO:comConnect.c:295:Connectivity state: STARTUP
2025-10-31T16:20:36.105Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-10-31T16:20:36.605Z:INFO:taskModbus.c:4526:Address #1: modbus meter vendor : ALF
2025-10-31T16:20:36.617Z:INFO:taskModbus.c:4527:Address #1: modbus meter model : D3001
2025-10-31T16:20:36.628Z:INFO:taskModbus.c:4528:Address #1: modbus meter revision : V1.03
2025-10-31T16:20:36.636Z:INFO:taskModbus.c:4529:Address #1: modbus meter meterNumber : 22391493
2025-10-31T16:20:36.648Z:USER:taskModbus.c:936:Socket_1 Meter(1): meter type DZG_REALLIN found
2025-10-31T16:20:36.976Z:INFO:taskNFCreader.c:579:Port #0 switch NFC power on
2025-10-31T16:20:37.050Z:INFO:taskMain.c:1419:Socket #1: main state: BOOTING, CP: 0.0/0.0, no tag
2025-10-31T16:20:37.152Z:USER:taskModbus.c:1107:Socket_1 Meter(1): first meter update, Multiple phase installation
2025-10-31T16:20:37.734Z:USER:bspEthernet.c:342:Mode: 100Mb/s full duplex
2025-10-31T16:20:37.746Z:INFO:taskTCPIP.c:958:Network Cable is now connected
2025-10-31T16:20:38.296Z:USER:taskMaster.c:1329:Node #1, version 7.3.0-4377
2025-10-31T16:20:38.437Z:INFO:taskTCPIP.c:1617: IP address assigned by DHCP
2025-10-31T16:20:38.445Z:INFO:taskTCPIP.c:1645:Network interface is up
2025-10-31T16:20:38.453Z:INFO:taskTCPIP.c:1654: IP : 192.168.178.184
2025-10-31T16:20:38.460Z:INFO:taskTCPIP.c:1655: Netmask : 255.255.255.0
2025-10-31T16:20:38.468Z:INFO:taskTCPIP.c:1656: Gateway : 192.168.178.1
2025-10-31T16:20:38.476Z:INFO:taskTCPIP.c:1657: DNS1 : 192.168.178.1
2025-10-31T16:20:38.484Z:INFO:taskTCPIP.c:1658: DNS2 : 208.67.220.220
2025-10-31T16:20:38.492Z:INFO:taskTCPIP.c:512:Starting mDNS on interface al
2025-10-31T16:20:38.500Z:INFO:taskTCPIP.c:512:Starting Webserver on interface al
2025-10-31T16:20:38.507Z:INFO:taskTCPIP.c:512:Starting Modbus on interface al
2025-10-31T16:20:38.515Z:INFO:taskTCPIP.c:512:Starting P1 on interface al
2025-10-31T16:20:38.523Z:INFO:taskTCPIP.c:512:Starting SCN on interface al
2025-10-31T16:20:38.535Z:INFO:taskTCPIP.c:413:default network set to 'al'
2025-10-31T16:20:38.546Z:INFO:taskWebServer.c:238:WebServer state WAIT_FOR_NETWORK -> SETUP
2025-10-31T16:20:38.582Z:USER:taskWebServer.c:360:WebServer started on port 443
2025-10-31T16:20:38.589Z:INFO:taskWebServer.c:238:WebServer state SETUP -> AVAILABLE
2025-10-31T16:20:41.015Z:INFO:taskNFCreader.c:115:Port #0 version response: "ICU NFC 243B (v3) v3.1-531"
2025-10-31T16:20:41.027Z:USER:taskMaster.c:1359:NFC version: ICU NFC 243B (v3) v3.1-531
2025-10-31T16:20:41.035Z:INFO:comConnect.c:1107:Connecting wired to: ws://192.168.178.140:8080/steve/websocket/CentralSystemServ
2025-10-31T16:20:41.035Z:INFO:comConnect.c:1107:ice/VAN_01971, prio #1
2025-10-31T16:20:41.121Z:INFO:comConnect.c:664:connection attempt 1/3
2025-10-31T16:20:41.152Z:INFO:comConnect.c:295:Connectivity state: INITIALISING
2025-10-31T16:20:41.187Z:INFO:taskNFCreader.c:131:Port #0 ICU NFC reader BL3 v3.1, 1 LEDs
2025-10-31T16:20:41.199Z:INFO:taskNFCreader.c:132:Port #0 reader model: Giro-e
2025-10-31T16:20:41.207Z:INFO:comConnect.c:295:Connectivity state: WIRED
2025-10-31T16:20:41.214Z:USER:application.c:718:Initialisation done
2025-10-31T16:20:41.226Z:INFO:taskTCPIP.c:1526:'al' is configured as default internet connection.
2025-10-31T16:20:41.238Z:INFO:taskTCPIP.c:1543:Renew DHCP leash for interface 'al'.
2025-10-31T16:20:41.269Z:USER:comConnect.c:383:wired connect
2025-10-31T16:20:41.292Z:INFO:websockets.c:451:Connected to Socket 192.168.178.140:8080
2025-10-31T16:20:41.328Z:INFO:websockets.c:2363:WS timeout: 10000 ms
2025-10-31T16:20:41.390Z:INFO:websockets.c:824:WebSocket upgrade successful
2025-10-31T16:20:41.429Z:USER:taskOCPP.c:464:Back office connection available
2025-10-31T16:20:41.707Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:20:42.292Z:SECURITY:httpd_login.c:149:Invalid password for user: 'admin'
2025-10-31T16:20:42.300Z:WARNING:web_functionali:101:Invalid username/password provided. Login not allowed
2025-10-31T16:20:42.320Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x0)
2025-10-31T16:20:42.332Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-31T16:20:42.402Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-31T16:20:43.281Z:INFO:modem.c:1124:Modem state InitHw->InitModem
2025-10-31T16:20:43.289Z:INFO:modem.c:1296:Reset delay 2s
2025-10-31T16:20:44.035Z:INFO:taskMaster.c:1137:Socket #1 has a Modbus meter
2025-10-31T16:20:44.046Z:USER:updatefirmware.:148:Updated from version 7.2.0-4362 to version 7.3.0-4377
2025-10-31T16:20:44.058Z:INFO:updatefirmware.:129:Execute PRE update actions for version 7.2.0-4362
2025-10-31T16:20:44.066Z:INFO:db_base.c:1325:Initialized Domain db (firstItem=0x00000000, lastItem=0x00000070)
2025-10-31T16:20:44.078Z:INFO:updatefirmware.c:52:BL FWU_STATUS_REBOOT -> int SEND_REPORT
2025-10-31T16:20:44.085Z:USER:taskMaster.c:1164:1 NFC readers found
2025-10-31T16:20:44.093Z:INFO:smartMeter.c:80:Set phases: (L1, L2, L3)->(L1, L2, L3)
2025-10-31T16:20:44.105Z:INFO:active_lb.c:308:SMt:(0.0 0.0 0.0)A Free:(25.0 25.0 25.0)A ALB:(0.0 0.0 0.0)A
2025-10-31T16:20:44.117Z:INFO:taskMaster.c:4957:Socket #1: state main : BOOTING
2025-10-31T16:20:44.125Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-10-31T16:20:44.132Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-10-31T16:20:44.140Z:INFO:taskMaster.c:4979:Socket #1: state led : BOOTING
2025-10-31T16:20:44.152Z:INFO:comFaults.c:482:Reset fault status
2025-10-31T16:20:45.187Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:20:45.585Z:SECURITY:httpd_login.c:155:WebClient RadomskiR connected (account: admin)
2025-10-31T16:20:46.460Z:COM:ocpp_rpc.c:704:-> [2,"1","BootNotification",{"chargePointVendor":"Alfen BV","chargePointModel":
2025-10-31T16:20:46.460Z:COM:ocpp_rpc.c:704:"NG910-60583","chargePointSerialNumber":"ACE0640314","chargeBoxSerialNumber":"VA
2025-10-31T16:20:46.460Z:COM:ocpp_rpc.c:704:N_01971","firmwareVersion":"7.3.0-4377"}]
2025-10-31T16:20:46.531Z:COM:ocpp_rpc.c:1297:<- [3,"1",{"status":"Accepted","currentTime":"2025-10-31T16:20:47.274Z","interva
2025-10-31T16:20:46.531Z:COM:ocpp_rpc.c:1297:l":14400}]
2025-10-31T16:20:46.875Z:INFO:web_functionali:159:Executing command: 'forcefirmwarepermanent'
2025-10-31T16:20:46.898Z:INFO:taskMaster.c:6376:Socket #1: no schedule
2025-10-31T16:20:46.906Z:USER:taskMaster.c:6402:Socket #1: external current limit 16.0 A
2025-10-31T16:20:46.914Z:INFO:station.c:97:station external max - new value: 99.9A
2025-10-31T16:20:47.484Z:USER:modem.c:3611:Modem type: Quectel BG95-M3
2025-10-31T16:20:47.500Z:INFO:modem.c:3090:Check if modem responds
2025-10-31T16:20:47.539Z:INFO:modem.c:2977:Set flow control (on)
2025-10-31T16:20:47.710Z:INFO:modem.c:3130:Set type of logging
2025-10-31T16:20:47.871Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x50)
2025-10-31T16:20:47.882Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-31T16:20:47.906Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-31T16:20:54.195Z:INFO:comFaults.c:1075:#phases: socket #1 ''->'L1L2L3'
2025-10-31T16:20:54.789Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:20:54.847Z:SECURITY:taskWebClient.c:446:Received unauthorized request, so removing client
2025-10-31T16:20:54.859Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-31T16:20:54.917Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-31T16:20:56.566Z:COM:ocpp_rpc.c:704:-> [2,"2","StatusNotification",{"connectorId":0,"errorCode":"NoError","status":"
2025-10-31T16:20:56.566Z:COM:ocpp_rpc.c:704:Unavailable"}]
2025-10-31T16:20:56.632Z:COM:ocpp_rpc.c:1297:<- [3,"2",{}]
2025-10-31T16:20:56.718Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:20:57.367Z:SECURITY:httpd_login.c:155:WebClient RadomskiR connected (account: admin)
2025-10-31T16:21:06.175Z:INFO:modem.c:2525:Check PIN
2025-10-31T16:21:09.949Z:WARNING:modem.c:2562:SIM error
2025-10-31T16:21:13.824Z:WARNING:modem.c:2562:SIM error
2025-10-31T16:21:14.242Z:SECURITY:updatefirmware.:123:UpdateFirmware done
2025-10-31T16:21:14.250Z:INFO:updatefirmware.:125:Socket #1: ResetFirmwareUpdate request sent
2025-10-31T16:21:14.261Z:COM:ocpp_rpc.c:704:-> [2,"3","FirmwareStatusNotification",{"status":"Installed"}]
2025-10-31T16:21:14.277Z:COM:ocpp_rpc.c:1297:<- [3,"3",{}]
2025-10-31T16:21:14.304Z:INFO:updatefirmware.:145:Version 7.3.0-4377 saved
2025-10-31T16:21:14.312Z:INFO:updatefirmware.:132:Execute POST update actions for version 7.2.0-4362
2025-10-31T16:21:14.335Z:INFO:db_base.c:1325:Initialized Transaction db (firstItem=0x00000000, lastItem=0x00001877)
2025-10-31T16:21:14.351Z:INFO:db_base.c:1325:Initialized LocalList db (firstItem=0x00000000, lastItem=0x00000000)
2025-10-31T16:21:14.363Z:INFO:db_base.c:1325:Initialized WhiteList db (firstItem=0x00000000, lastItem=0x00000041)
2025-10-31T16:21:14.375Z:INFO:db_base.c:1325:Initialized ChargingProfile db (firstItem=0x00000000, lastItem=0x000001b1)
2025-10-31T16:21:14.398Z:INFO:taskMain.c:1724:Socket #1: recovered INOPERATIVE
2025-10-31T16:21:14.410Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:21:14.417Z:INFO:taskCANopen.c:1212:Persistent memory not cached
2025-10-31T16:21:14.445Z:INFO:taskMaster.c:4957:Socket #1: state main : INOPERATIVE
2025-10-31T16:21:14.472Z:INFO:taskMaster.c:1575:Socket #1: no open transaction
2025-10-31T16:21:14.500Z:INFO:taskMaster.c:4979:Socket #1: state led : INOPERATIVE
2025-10-31T16:21:14.511Z:USER:taskMaster.c:1359:NFC version: ICU NFC 243B (v3) v3.1-531
2025-10-31T16:21:14.519Z:COM:ocpp_rpc.c:704:-> [2,"4","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":"
2025-10-31T16:21:14.519Z:COM:ocpp_rpc.c:704:Unavailable"}]
2025-10-31T16:21:14.546Z:INFO:taskCANopen.c:2020:CanOpen EEPROM cache size: 284, got 282 objects <282,0>
2025-10-31T16:21:14.558Z:COM:ocpp_rpc.c:1297:<- [3,"4",{}]
2025-10-31T16:21:14.574Z:INFO:taskCANopen.c:1787:Updated object 0x2056, 4 bytes
2025-10-31T16:21:14.613Z:INFO:taskCANopen.c:1787:Updated object 0x2057, 51 bytes
2025-10-31T16:21:14.984Z:INFO:taskCANopen.c:1821:Added object 0x213f, 2 bytes
2025-10-31T16:21:15.359Z:INFO:taskCANopen.c:1821:Added object 0x3296, 16 bytes
2025-10-31T16:21:15.425Z:INFO:taskMain.c:1419:Socket #1: main state: INOPERATIVE, CP: 0.0/0.0, no tag
2025-10-31T16:21:15.539Z:WARNING:taskCANopen.c:1938:Cannot add cache entry for object 0x3297
2025-10-31T16:21:15.722Z:WARNING:taskCANopen.c:1938:Cannot add cache entry for object 0x3298
2025-10-31T16:21:15.906Z:WARNING:taskCANopen.c:1938:Cannot add cache entry for object 0x3299
2025-10-31T16:21:16.089Z:WARNING:taskCANopen.c:1938:Cannot add cache entry for object 0x3300
2025-10-31T16:21:16.105Z:INFO:taskCANopen.c:1834:Need to refresh persistent storage
2025-10-31T16:21:17.312Z:INFO:taskCANopen.c:2020:CanOpen EEPROM cache size: 284, got 0 objects <0,0>
2025-10-31T16:21:17.332Z:INFO:taskCANopen.c:1821:Added object 0x204f, 2 bytes
2025-10-31T16:21:17.351Z:INFO:taskCANopen.c:1821:Added object 0x2050, 21 bytes
2025-10-31T16:21:17.371Z:INFO:taskCANopen.c:1821:Added object 0x2051, 26 bytes
2025-10-31T16:21:17.402Z:INFO:taskCANopen.c:1821:Added object 0x2052, 23 bytes
2025-10-31T16:21:17.421Z:INFO:taskCANopen.c:1821:Added object 0x2053, 21 bytes
2025-10-31T16:21:17.449Z:INFO:taskCANopen.c:1821:Added object 0x2055, 21 bytes
2025-10-31T16:21:17.472Z:INFO:taskCANopen.c:1821:Added object 0x2056, 4 bytes
2025-10-31T16:21:17.496Z:INFO:taskCANopen.c:1821:Added object 0x2057, 51 bytes
2025-10-31T16:21:17.519Z:INFO:taskCANopen.c:1821:Added object 0x205a, 1 bytes
2025-10-31T16:21:17.542Z:INFO:taskCANopen.c:1821:Added object 0x205b, 1 bytes
2025-10-31T16:21:17.566Z:INFO:taskCANopen.c:1821:Added object 0x205c, 8 bytes
2025-10-31T16:21:17.589Z:INFO:taskCANopen.c:1821:Added object 0x205d, 9 bytes
2025-10-31T16:21:17.617Z:INFO:taskCANopen.c:1821:Added object 0x205f, 8 bytes
2025-10-31T16:21:17.644Z:INFO:taskCANopen.c:1821:Added object 0x2061, 2 bytes
2025-10-31T16:21:17.667Z:INFO:taskCANopen.c:1821:Added object 0x2062, 4 bytes
2025-10-31T16:21:17.695Z:INFO:taskCANopen.c:1821:Added object 0x2063, 21 bytes
2025-10-31T16:21:17.722Z:INFO:taskCANopen.c:1821:Added object 0x2064, 1 bytes
2025-10-31T16:21:17.761Z:INFO:taskCANopen.c:1821:Added object 0x2065, 4 bytes
2025-10-31T16:21:17.789Z:INFO:taskCANopen.c:1821:Added object 0x2067, 4 bytes
2025-10-31T16:21:17.816Z:INFO:taskCANopen.c:1821:Added object 0x2068, 4 bytes
2025-10-31T16:21:17.828Z:WARNING:modem.c:2562:SIM error
2025-10-31T16:21:17.847Z:INFO:taskCANopen.c:1821:Added object 0x2069, 7 bytes
2025-10-31T16:21:17.878Z:INFO:taskCANopen.c:1821:Added object 0x206a, 4 bytes
2025-10-31T16:21:17.929Z:INFO:taskCANopen.c:1821:Added object 0x206b, 6 bytes
2025-10-31T16:21:17.996Z:INFO:taskCANopen.c:1821:Added object 0x206c, 12 bytes
2025-10-31T16:21:18.027Z:INFO:taskCANopen.c:1821:Added object 0x206e, 2 bytes
2025-10-31T16:21:18.058Z:INFO:taskCANopen.c:1821:Added object 0x206f, 1 bytes
2025-10-31T16:21:18.089Z:INFO:taskCANopen.c:1821:Added object 0x2070, 1 bytes
2025-10-31T16:21:18.132Z:INFO:taskCANopen.c:1821:Added object 0x2072, 18 bytes
2025-10-31T16:21:18.175Z:INFO:taskCANopen.c:1821:Added object 0x2073, 18 bytes
2025-10-31T16:21:18.222Z:INFO:taskCANopen.c:1821:Added object 0x2074, 18 bytes
2025-10-31T16:21:18.265Z:INFO:taskCANopen.c:1821:Added object 0x2075, 18 bytes
2025-10-31T16:21:18.300Z:INFO:taskCANopen.c:1821:Added object 0x2076, 51 bytes
2025-10-31T16:21:18.347Z:INFO:taskCANopen.c:1821:Added object 0x2079, 18 bytes
2025-10-31T16:21:18.394Z:INFO:taskCANopen.c:1821:Added object 0x207a, 18 bytes
2025-10-31T16:21:18.445Z:INFO:taskCANopen.c:1821:Added object 0x207b, 18 bytes
2025-10-31T16:21:18.496Z:INFO:taskCANopen.c:1821:Added object 0x207c, 18 bytes
2025-10-31T16:21:18.542Z:INFO:taskCANopen.c:1821:Added object 0x207d, 18 bytes
2025-10-31T16:21:18.589Z:INFO:taskCANopen.c:1821:Added object 0x207e, 18 bytes
2025-10-31T16:21:18.640Z:INFO:taskCANopen.c:1821:Added object 0x207f, 18 bytes
2025-10-31T16:21:18.691Z:INFO:taskCANopen.c:1821:Added object 0x2080, 18 bytes
2025-10-31T16:21:18.730Z:INFO:taskCANopen.c:1821:Added object 0x2085, 4 bytes
2025-10-31T16:21:18.773Z:INFO:taskCANopen.c:1821:Added object 0x2087, 4 bytes
2025-10-31T16:21:18.812Z:INFO:taskCANopen.c:1821:Added object 0x2088, 1 bytes
2025-10-31T16:21:18.855Z:INFO:taskCANopen.c:1821:Added object 0x2089, 1 bytes
2025-10-31T16:21:18.898Z:INFO:taskCANopen.c:1821:Added object 0x208a, 4 bytes
2025-10-31T16:21:18.941Z:INFO:taskCANopen.c:1821:Added object 0x208c, 4 bytes
2025-10-31T16:21:18.984Z:INFO:taskCANopen.c:1821:Added object 0x208d, 4 bytes
2025-10-31T16:21:19.027Z:INFO:taskCANopen.c:1821:Added object 0x208e, 4 bytes
2025-10-31T16:21:19.070Z:INFO:taskCANopen.c:1821:Added object 0x208f, 2 bytes
2025-10-31T16:21:19.117Z:INFO:taskCANopen.c:1821:Added object 0x2094, 1 bytes
2025-10-31T16:21:19.164Z:INFO:taskCANopen.c:1821:Added object 0x2095, 1 bytes
2025-10-31T16:21:19.207Z:INFO:taskCANopen.c:1821:Added object 0x2096, 2 bytes
2025-10-31T16:21:19.234Z:INFO:taskWifi.c:671:WiFi Module: Not Initialized --> Running
2025-10-31T16:21:19.253Z:INFO:taskCANopen.c:1821:Added object 0x2097, 4 bytes
2025-10-31T16:21:19.300Z:INFO:taskCANopen.c:1821:Added object 0x2098, 36 bytes
2025-10-31T16:21:19.347Z:INFO:taskCANopen.c:1821:Added object 0x2099, 36 bytes
2025-10-31T16:21:19.398Z:INFO:taskCANopen.c:1821:Added object 0x209a, 4 bytes
2025-10-31T16:21:19.445Z:INFO:taskCANopen.c:1821:Added object 0x209b, 1 bytes
2025-10-31T16:21:19.496Z:INFO:taskCANopen.c:1821:Added object 0x209c, 1 bytes
2025-10-31T16:21:19.542Z:INFO:taskCANopen.c:1821:Added object 0x209d, 1 bytes
2025-10-31T16:21:19.714Z:INFO:taskCANopen.c:1821:Added object 0x20f0, 1142 bytes
2025-10-31T16:21:19.898Z:INFO:taskCANopen.c:1821:Added object 0x20f1, 1142 bytes
2025-10-31T16:21:20.070Z:INFO:taskCANopen.c:1821:Added object 0x20f2, 1142 bytes
2025-10-31T16:21:20.250Z:INFO:taskCANopen.c:1821:Added object 0x20f3, 1142 bytes
2025-10-31T16:21:20.304Z:INFO:taskCANopen.c:1821:Added object 0x20f4, 1 bytes
2025-10-31T16:21:20.355Z:INFO:taskCANopen.c:1821:Added object 0x20f5, 1 bytes
2025-10-31T16:21:20.410Z:INFO:taskCANopen.c:1821:Added object 0x20f6, 1 bytes
2025-10-31T16:21:20.464Z:INFO:taskCANopen.c:1821:Added object 0x20f7, 1 bytes
2025-10-31T16:21:20.519Z:INFO:taskCANopen.c:1821:Added object 0x2106, 1 bytes
2025-10-31T16:21:20.574Z:INFO:taskCANopen.c:1821:Added object 0x2107, 1 bytes
2025-10-31T16:21:20.628Z:INFO:taskCANopen.c:1821:Added object 0x2108, 1 bytes
2025-10-31T16:21:20.683Z:INFO:taskCANopen.c:1821:Added object 0x2109, 1 bytes
2025-10-31T16:21:20.742Z:INFO:taskCANopen.c:1821:Added object 0x2111, 2 bytes
2025-10-31T16:21:20.796Z:INFO:taskCANopen.c:1821:Added object 0x2113, 1 bytes
2025-10-31T16:21:20.808Z:INFO:wifi.c:451:Successfully started AP <ACE0640314> ip<192.168.50.10>
2025-10-31T16:21:20.816Z:INFO:taskWifi.c:982:Start WiFi AP
2025-10-31T16:21:20.824Z:WARNING:taskWifi.c:1061:Wifi config is not valid
2025-10-31T16:21:20.832Z:INFO:taskWifi.c:678:SoftAP: Not Initialized --> Enabled
2025-10-31T16:21:20.843Z:INFO:taskWifi.c:685:STA: Not Initialized --> Not Configured
2025-10-31T16:21:20.855Z:INFO:taskCANopen.c:1821:Added object 0x2114, 1 bytes
2025-10-31T16:21:20.914Z:INFO:taskCANopen.c:1821:Added object 0x2115, 64 bytes
2025-10-31T16:21:20.976Z:INFO:taskCANopen.c:1821:Added object 0x2116, 32 bytes
2025-10-31T16:21:21.039Z:INFO:taskCANopen.c:1821:Added object 0x2117, 1 bytes
2025-10-31T16:21:21.097Z:INFO:taskCANopen.c:1821:Added object 0x2124, 1 bytes
2025-10-31T16:21:21.156Z:INFO:taskCANopen.c:1821:Added object 0x2125, 1 bytes
2025-10-31T16:21:21.218Z:INFO:taskCANopen.c:1821:Added object 0x2126, 1 bytes
2025-10-31T16:21:21.277Z:INFO:taskCANopen.c:1821:Added object 0x2127, 1 bytes
2025-10-31T16:21:21.339Z:INFO:taskCANopen.c:1821:Added object 0x2129, 4 bytes
2025-10-31T16:21:21.402Z:INFO:taskCANopen.c:1821:Added object 0x2130, 4 bytes
2025-10-31T16:21:21.464Z:INFO:taskCANopen.c:1821:Added object 0x2131, 1 bytes
2025-10-31T16:21:21.527Z:INFO:taskCANopen.c:1821:Added object 0x2132, 2 bytes
2025-10-31T16:21:21.589Z:INFO:taskCANopen.c:1821:Added object 0x2133, 2 bytes
2025-10-31T16:21:21.656Z:INFO:taskCANopen.c:1821:Added object 0x2134, 2 bytes
2025-10-31T16:21:21.718Z:INFO:taskCANopen.c:1821:Added object 0x2135, 2 bytes
2025-10-31T16:21:21.742Z:WARNING:modem.c:2562:SIM error
2025-10-31T16:21:21.785Z:INFO:taskCANopen.c:1821:Added object 0x2136, 2 bytes
2025-10-31T16:21:21.847Z:INFO:modem.c:2572:Check PIN failed
2025-10-31T16:21:21.855Z:INFO:taskCANopen.c:1821:Added object 0x2137, 1 bytes
2025-10-31T16:21:21.921Z:INFO:taskCANopen.c:1821:Added object 0x2138, 1 bytes
2025-10-31T16:21:21.988Z:INFO:taskCANopen.c:1821:Added object 0x2139, 2 bytes
2025-10-31T16:21:22.066Z:INFO:taskCANopen.c:1821:Added object 0x213b, 1 bytes
2025-10-31T16:21:22.140Z:INFO:taskCANopen.c:1821:Added object 0x213c, 1 bytes
2025-10-31T16:21:22.222Z:INFO:taskCANopen.c:1821:Added object 0x213d, 1 bytes
2025-10-31T16:21:22.292Z:INFO:taskCANopen.c:1821:Added object 0x213e, 1 bytes
2025-10-31T16:21:22.359Z:INFO:taskCANopen.c:1821:Added object 0x213f, 2 bytes
2025-10-31T16:21:22.429Z:INFO:taskCANopen.c:1821:Added object 0x2140, 2 bytes
2025-10-31T16:21:22.500Z:INFO:taskCANopen.c:1821:Added object 0x2142, 2 bytes
2025-10-31T16:21:22.570Z:INFO:taskCANopen.c:1821:Added object 0x2143, 2 bytes
2025-10-31T16:21:22.644Z:INFO:taskCANopen.c:1821:Added object 0x2144, 1 bytes
2025-10-31T16:21:22.714Z:INFO:taskCANopen.c:1821:Added object 0x2146, 2 bytes
2025-10-31T16:21:22.789Z:INFO:taskCANopen.c:1821:Added object 0x2148, 2 bytes
2025-10-31T16:21:22.859Z:INFO:taskCANopen.c:1821:Added object 0x2149, 2 bytes
2025-10-31T16:21:22.933Z:INFO:taskCANopen.c:1821:Added object 0x2150, 2 bytes
2025-10-31T16:21:23.007Z:INFO:taskCANopen.c:1821:Added object 0x2153, 2 bytes
2025-10-31T16:21:23.089Z:INFO:taskCANopen.c:1821:Added object 0x2155, 1 bytes
2025-10-31T16:21:23.164Z:INFO:taskCANopen.c:1821:Added object 0x2156, 1 bytes
2025-10-31T16:21:23.238Z:INFO:taskCANopen.c:1821:Added object 0x2158, 2 bytes
2025-10-31T16:21:23.316Z:INFO:taskCANopen.c:1821:Added object 0x2159, 1 bytes
2025-10-31T16:21:23.390Z:INFO:taskCANopen.c:1821:Added object 0x215c, 1 bytes
2025-10-31T16:21:23.468Z:INFO:taskCANopen.c:1821:Added object 0x215d, 1 bytes
2025-10-31T16:21:23.546Z:INFO:taskCANopen.c:1821:Added object 0x215e, 1 bytes
2025-10-31T16:21:23.625Z:INFO:taskCANopen.c:1821:Added object 0x2162, 2 bytes
2025-10-31T16:21:23.703Z:INFO:taskCANopen.c:1821:Added object 0x2164, 1 bytes
2025-10-31T16:21:23.781Z:INFO:taskCANopen.c:1821:Added object 0x2168, 2 bytes
2025-10-31T16:21:23.863Z:INFO:taskCANopen.c:1821:Added object 0x2169, 2 bytes
2025-10-31T16:21:23.941Z:INFO:taskCANopen.c:1821:Added object 0x216a, 1 bytes
2025-10-31T16:21:24.023Z:INFO:taskCANopen.c:1821:Added object 0x216b, 1 bytes
2025-10-31T16:21:24.105Z:INFO:taskCANopen.c:1821:Added object 0x216c, 1 bytes
2025-10-31T16:21:24.187Z:INFO:taskCANopen.c:1821:Added object 0x216d, 1 bytes
2025-10-31T16:21:24.269Z:INFO:taskCANopen.c:1821:Added object 0x216f, 1 bytes
2025-10-31T16:21:24.351Z:INFO:taskCANopen.c:1821:Added object 0x2171, 1 bytes
2025-10-31T16:21:24.433Z:INFO:taskCANopen.c:1821:Added object 0x2172, 1 bytes
2025-10-31T16:21:24.519Z:INFO:taskCANopen.c:1821:Added object 0x2173, 4 bytes
2025-10-31T16:21:24.601Z:INFO:taskCANopen.c:1821:Added object 0x2174, 4 bytes
2025-10-31T16:21:24.695Z:INFO:taskCANopen.c:1821:Added object 0x2177, 224 bytes
2025-10-31T16:21:24.792Z:INFO:taskCANopen.c:1821:Added object 0x2178, 224 bytes
2025-10-31T16:21:24.878Z:INFO:taskCANopen.c:1821:Added object 0x2179, 1 bytes
2025-10-31T16:21:25.015Z:INFO:taskCANopen.c:1821:Added object 0x2180, 28 bytes
2025-10-31T16:21:25.101Z:INFO:taskCANopen.c:1821:Added object 0x2182, 2 bytes
2025-10-31T16:21:25.191Z:INFO:taskCANopen.c:1821:Added object 0x2183, 1 bytes
2025-10-31T16:21:25.277Z:INFO:taskCANopen.c:1821:Added object 0x2184, 2 bytes
2025-10-31T16:21:25.367Z:INFO:taskCANopen.c:1821:Added object 0x2185, 1 bytes
2025-10-31T16:21:25.457Z:INFO:taskCANopen.c:1821:Added object 0x2187, 8 bytes
2025-10-31T16:21:25.542Z:INFO:taskCANopen.c:1821:Added object 0x2188, 1 bytes
2025-10-31T16:21:25.636Z:INFO:taskCANopen.c:1821:Added object 0x2189, 1 bytes
2025-10-31T16:21:25.726Z:INFO:taskCANopen.c:1821:Added object 0x218a, 1 bytes
2025-10-31T16:21:25.816Z:INFO:taskCANopen.c:1821:Added object 0x218b, 1 bytes
2025-10-31T16:21:25.910Z:INFO:taskCANopen.c:1821:Added object 0x218e, 4 bytes
2025-10-31T16:21:26.003Z:INFO:taskCANopen.c:1821:Added object 0x2190, 1 bytes
2025-10-31T16:21:26.109Z:INFO:taskCANopen.c:1821:Added object 0x2191, 20 bytes
2025-10-31T16:21:26.207Z:INFO:taskCANopen.c:1821:Added object 0x2192, 1 bytes
2025-10-31T16:21:26.304Z:INFO:taskCANopen.c:1821:Added object 0x21a1, 30 bytes
2025-10-31T16:21:26.402Z:INFO:taskCANopen.c:1821:Added object 0x21b0, 1 bytes
2025-10-31T16:21:26.496Z:INFO:taskCANopen.c:1821:Added object 0x21b1, 1 bytes
2025-10-31T16:21:26.593Z:INFO:taskCANopen.c:1821:Added object 0x21b2, 1 bytes
2025-10-31T16:21:26.691Z:INFO:taskCANopen.c:1821:Added object 0x21b3, 8 bytes
2025-10-31T16:21:26.789Z:INFO:taskCANopen.c:1821:Added object 0x21b4, 1 bytes
2025-10-31T16:21:26.886Z:INFO:taskCANopen.c:1821:Added object 0x21b5, 1 bytes
2025-10-31T16:21:26.984Z:INFO:taskCANopen.c:1821:Added object 0x21b6, 8 bytes
2025-10-31T16:21:27.082Z:INFO:taskCANopen.c:1821:Added object 0x21b7, 1 bytes
2025-10-31T16:21:27.195Z:INFO:taskCANopen.c:1821:Added object 0x21b9, 2 bytes
2025-10-31T16:21:27.316Z:INFO:taskCANopen.c:1821:Added object 0x2200, 1 bytes
2025-10-31T16:21:27.417Z:INFO:taskCANopen.c:1821:Added object 0x2202, 4 bytes
2025-10-31T16:21:27.519Z:INFO:taskCANopen.c:1821:Added object 0x2203, 4 bytes
2025-10-31T16:21:27.621Z:INFO:taskCANopen.c:1821:Added object 0x2204, 2 bytes
2025-10-31T16:21:27.722Z:INFO:taskCANopen.c:1821:Added object 0x2205, 2 bytes
2025-10-31T16:21:27.824Z:INFO:taskCANopen.c:1821:Added object 0x2206, 1 bytes
2025-10-31T16:21:27.925Z:INFO:taskCANopen.c:1821:Added object 0x2210, 2 bytes
2025-10-31T16:21:28.027Z:INFO:taskCANopen.c:1821:Added object 0x2211, 2 bytes
2025-10-31T16:21:28.132Z:INFO:taskCANopen.c:1821:Added object 0x2212, 2 bytes
2025-10-31T16:21:28.234Z:INFO:taskCANopen.c:1821:Added object 0x2213, 2 bytes
2025-10-31T16:21:28.339Z:INFO:taskCANopen.c:1821:Added object 0x2214, 2 bytes
2025-10-31T16:21:28.445Z:INFO:taskCANopen.c:1821:Added object 0x2215, 2 bytes
2025-10-31T16:21:28.550Z:INFO:taskCANopen.c:1821:Added object 0x2216, 2 bytes
2025-10-31T16:21:28.656Z:INFO:taskCANopen.c:1821:Added object 0x2218, 1 bytes
2025-10-31T16:21:28.761Z:INFO:taskCANopen.c:1821:Added object 0x2219, 2 bytes
2025-10-31T16:21:28.871Z:INFO:taskCANopen.c:1821:Added object 0x2220, 8 bytes
2025-10-31T16:21:28.992Z:INFO:taskCANopen.c:1821:Added object 0x2249, 9 bytes
2025-10-31T16:21:29.101Z:INFO:taskCANopen.c:1821:Added object 0x2250, 1 bytes
2025-10-31T16:21:29.210Z:INFO:taskCANopen.c:1821:Added object 0x2300, 10 bytes
2025-10-31T16:21:29.320Z:INFO:taskCANopen.c:1821:Added object 0x2301, 10 bytes
2025-10-31T16:21:29.429Z:INFO:taskCANopen.c:1821:Added object 0x2302, 10 bytes
2025-10-31T16:21:29.539Z:INFO:taskCANopen.c:1821:Added object 0x2303, 10 bytes
2025-10-31T16:21:29.652Z:INFO:taskCANopen.c:1821:Added object 0x2304, 10 bytes
2025-10-31T16:21:29.761Z:INFO:taskCANopen.c:1821:Added object 0x2305, 10 bytes
2025-10-31T16:21:29.875Z:INFO:taskCANopen.c:1821:Added object 0x2306, 10 bytes
2025-10-31T16:21:29.988Z:INFO:taskCANopen.c:1821:Added object 0x2307, 10 bytes
2025-10-31T16:21:30.101Z:INFO:taskCANopen.c:1821:Added object 0x2308, 10 bytes
2025-10-31T16:21:30.214Z:INFO:taskCANopen.c:1821:Added object 0x2309, 10 bytes
2025-10-31T16:21:30.328Z:INFO:taskCANopen.c:1821:Added object 0x2310, 10 bytes
2025-10-31T16:21:30.445Z:INFO:taskCANopen.c:1821:Added object 0x2311, 10 bytes
2025-10-31T16:21:30.558Z:INFO:taskCANopen.c:1821:Added object 0x2312, 10 bytes
2025-10-31T16:21:30.675Z:INFO:taskCANopen.c:1821:Added object 0x2313, 10 bytes
2025-10-31T16:21:30.796Z:INFO:taskCANopen.c:1821:Added object 0x2314, 10 bytes
2025-10-31T16:21:30.914Z:INFO:taskCANopen.c:1821:Added object 0x2315, 10 bytes
2025-10-31T16:21:31.031Z:INFO:taskCANopen.c:1821:Added object 0x2316, 10 bytes
2025-10-31T16:21:31.148Z:INFO:taskCANopen.c:1821:Added object 0x2317, 10 bytes
2025-10-31T16:21:31.265Z:INFO:taskCANopen.c:1821:Added object 0x2318, 10 bytes
2025-10-31T16:21:31.386Z:INFO:taskCANopen.c:1821:Added object 0x2319, 10 bytes
2025-10-31T16:21:31.503Z:INFO:taskCANopen.c:1821:Added object 0x2320, 10 bytes
2025-10-31T16:21:31.625Z:INFO:taskCANopen.c:1821:Added object 0x2321, 10 bytes
2025-10-31T16:21:31.746Z:INFO:taskCANopen.c:1821:Added object 0x2322, 10 bytes
2025-10-31T16:21:31.867Z:INFO:taskCANopen.c:1821:Added object 0x2323, 10 bytes
2025-10-31T16:21:31.988Z:INFO:taskCANopen.c:1821:Added object 0x2324, 10 bytes
2025-10-31T16:21:32.140Z:INFO:taskCANopen.c:1821:Added object 0x2325, 10 bytes
2025-10-31T16:21:32.269Z:INFO:taskCANopen.c:1821:Added object 0x2326, 10 bytes
2025-10-31T16:21:32.394Z:INFO:taskCANopen.c:1821:Added object 0x2327, 10 bytes
2025-10-31T16:21:32.515Z:INFO:taskCANopen.c:1821:Added object 0x2328, 10 bytes
2025-10-31T16:21:32.640Z:INFO:taskCANopen.c:1821:Added object 0x2329, 10 bytes
2025-10-31T16:21:32.769Z:INFO:taskCANopen.c:1821:Added object 0x2330, 10 bytes
2025-10-31T16:21:32.894Z:INFO:taskCANopen.c:1821:Added object 0x2331, 10 bytes
2025-10-31T16:21:33.019Z:INFO:taskCANopen.c:1821:Added object 0x2332, 10 bytes
2025-10-31T16:21:33.144Z:INFO:taskCANopen.c:1821:Added object 0x2333, 10 bytes
2025-10-31T16:21:33.273Z:INFO:taskCANopen.c:1821:Added object 0x2334, 10 bytes
2025-10-31T16:21:33.398Z:INFO:taskCANopen.c:1821:Added object 0x2335, 10 bytes
2025-10-31T16:21:33.527Z:INFO:taskCANopen.c:1821:Added object 0x2336, 10 bytes
2025-10-31T16:21:33.656Z:INFO:taskCANopen.c:1821:Added object 0x2337, 10 bytes
2025-10-31T16:21:33.781Z:INFO:taskCANopen.c:1821:Added object 0x2338, 10 bytes
2025-10-31T16:21:33.910Z:INFO:taskCANopen.c:1821:Added object 0x2350, 10 bytes
2025-10-31T16:21:34.050Z:INFO:taskCANopen.c:1821:Added object 0x2400, 23 bytes
2025-10-31T16:21:34.183Z:INFO:taskCANopen.c:1821:Added object 0x2401, 37 bytes
2025-10-31T16:21:34.343Z:INFO:taskCANopen.c:1821:Added object 0x2522, 24 bytes
2025-10-31T16:21:34.503Z:INFO:taskCANopen.c:1821:Added object 0x2523, 24 bytes
2025-10-31T16:21:34.656Z:INFO:taskCANopen.c:1821:Added object 0x2530, 6 bytes
2025-10-31T16:21:34.789Z:INFO:taskCANopen.c:1821:Added object 0x2560, 50 bytes
2025-10-31T16:21:34.925Z:INFO:taskCANopen.c:1821:Added object 0x2561, 100 bytes
2025-10-31T16:21:35.058Z:INFO:taskCANopen.c:1821:Added object 0x2562, 50 bytes
2025-10-31T16:21:35.199Z:INFO:taskCANopen.c:1821:Added object 0x2563, 50 bytes
2025-10-31T16:21:35.351Z:INFO:taskCANopen.c:1821:Added object 0x2564, 11 bytes
2025-10-31T16:21:35.503Z:INFO:taskCANopen.c:1821:Added object 0x2565, 7 bytes
2025-10-31T16:21:35.640Z:INFO:taskCANopen.c:1821:Added object 0x2570, 50 bytes
2025-10-31T16:21:35.777Z:INFO:taskCANopen.c:1821:Added object 0x2571, 100 bytes
2025-10-31T16:21:35.917Z:INFO:taskCANopen.c:1821:Added object 0x2572, 50 bytes
2025-10-31T16:21:36.058Z:INFO:taskCANopen.c:1821:Added object 0x2573, 50 bytes
2025-10-31T16:21:36.214Z:INFO:taskCANopen.c:1821:Added object 0x2574, 11 bytes
2025-10-31T16:21:36.371Z:INFO:taskCANopen.c:1821:Added object 0x2575, 7 bytes
2025-10-31T16:21:36.511Z:INFO:taskCANopen.c:1821:Added object 0x2703, 1 bytes
2025-10-31T16:21:36.652Z:INFO:taskCANopen.c:1821:Added object 0x2710, 1 bytes
2025-10-31T16:21:36.792Z:INFO:taskCANopen.c:1821:Added object 0x2722, 51 bytes
2025-10-31T16:21:36.863Z:INFO:modem.c:3291:Get other info
2025-10-31T16:21:36.933Z:INFO:taskCANopen.c:1821:Added object 0x2723, 1 bytes
2025-10-31T16:21:37.074Z:INFO:taskCANopen.c:1821:Added object 0x2909, 4 bytes
2025-10-31T16:21:37.242Z:INFO:taskCANopen.c:1821:Added object 0x3125, 1 bytes
2025-10-31T16:21:37.394Z:INFO:taskCANopen.c:1821:Added object 0x3129, 4 bytes
2025-10-31T16:21:37.535Z:INFO:taskCANopen.c:1821:Added object 0x3160, 4 bytes
2025-10-31T16:21:37.675Z:INFO:taskCANopen.c:1821:Added object 0x3173, 4 bytes
2025-10-31T16:21:37.824Z:INFO:taskCANopen.c:1821:Added object 0x3218, 1 bytes
2025-10-31T16:21:37.968Z:INFO:taskCANopen.c:1821:Added object 0x3220, 8 bytes
2025-10-31T16:21:38.113Z:INFO:taskCANopen.c:1821:Added object 0x3258, 4 bytes
2025-10-31T16:21:38.257Z:INFO:taskCANopen.c:1821:Added object 0x3261, 2 bytes
2025-10-31T16:21:38.437Z:INFO:taskCANopen.c:1821:Added object 0x3262, 55 bytes
2025-10-31T16:21:38.628Z:INFO:taskCANopen.c:1821:Added object 0x3263, 519 bytes
2025-10-31T16:21:38.777Z:INFO:taskCANopen.c:1821:Added object 0x3264, 4 bytes
2025-10-31T16:21:38.921Z:INFO:taskCANopen.c:1821:Added object 0x3265, 4 bytes
2025-10-31T16:21:39.070Z:INFO:taskCANopen.c:1821:Added object 0x3266, 1 bytes
2025-10-31T16:21:39.218Z:INFO:taskCANopen.c:1821:Added object 0x3267, 1 bytes
2025-10-31T16:21:39.367Z:INFO:taskCANopen.c:1821:Added object 0x3268, 1 bytes
2025-10-31T16:21:39.515Z:INFO:taskCANopen.c:1821:Added object 0x3269, 1 bytes
2025-10-31T16:21:39.664Z:INFO:taskCANopen.c:1821:Added object 0x3270, 4 bytes
2025-10-31T16:21:39.816Z:INFO:taskCANopen.c:1821:Added object 0x3271, 14 bytes
2025-10-31T16:21:39.964Z:INFO:taskCANopen.c:1821:Added object 0x3272, 1 bytes
2025-10-31T16:21:40.117Z:INFO:taskCANopen.c:1821:Added object 0x3273, 3 bytes
2025-10-31T16:21:40.265Z:INFO:taskCANopen.c:1821:Added object 0x3274, 1 bytes
2025-10-31T16:21:40.421Z:INFO:taskCANopen.c:1821:Added object 0x3275, 4 bytes
2025-10-31T16:21:40.617Z:INFO:taskCANopen.c:1821:Added object 0x3276, 132 bytes
2025-10-31T16:21:40.808Z:INFO:taskCANopen.c:1821:Added object 0x3277, 14 bytes
2025-10-31T16:21:40.988Z:INFO:taskCANopen.c:1821:Added object 0x3280, 9 bytes
2025-10-31T16:21:41.140Z:INFO:taskCANopen.c:1821:Added object 0x3281, 10 bytes
2025-10-31T16:21:41.296Z:INFO:taskCANopen.c:1821:Added object 0x3282, 10 bytes
2025-10-31T16:21:41.453Z:INFO:taskCANopen.c:1821:Added object 0x3283, 10 bytes
2025-10-31T16:21:41.605Z:INFO:taskCANopen.c:1821:Added object 0x3284, 1 bytes
2025-10-31T16:21:41.773Z:INFO:taskCANopen.c:1821:Added object 0x3285, 18 bytes
2025-10-31T16:21:41.941Z:INFO:taskCANopen.c:1821:Added object 0x3286, 18 bytes
2025-10-31T16:21:42.113Z:INFO:taskCANopen.c:1821:Added object 0x3287, 18 bytes
2025-10-31T16:21:42.289Z:INFO:taskCANopen.c:1821:Added object 0x3288, 18 bytes
2025-10-31T16:21:42.460Z:INFO:taskCANopen.c:1821:Added object 0x3289, 18 bytes
2025-10-31T16:21:42.636Z:INFO:taskCANopen.c:1821:Added object 0x328a, 33 bytes
2025-10-31T16:21:42.796Z:INFO:taskCANopen.c:1821:Added object 0x328b, 65 bytes
2025-10-31T16:21:42.957Z:INFO:taskCANopen.c:1821:Added object 0x328c, 4 bytes
2025-10-31T16:21:43.117Z:INFO:taskCANopen.c:1821:Added object 0x3290, 4 bytes
2025-10-31T16:21:43.277Z:INFO:taskCANopen.c:1821:Added object 0x3291, 1 bytes
2025-10-31T16:21:43.441Z:INFO:taskCANopen.c:1821:Added object 0x3295, 30 bytes
2025-10-31T16:21:43.613Z:INFO:taskCANopen.c:1821:Added object 0x3296, 16 bytes
2025-10-31T16:21:43.789Z:INFO:taskCANopen.c:1821:Added object 0x3297, 16 bytes
2025-10-31T16:21:43.960Z:INFO:taskCANopen.c:1821:Added object 0x3298, 18 bytes
2025-10-31T16:21:44.136Z:INFO:taskCANopen.c:1821:Added object 0x3299, 18 bytes
2025-10-31T16:21:44.308Z:INFO:taskCANopen.c:1821:Added object 0x3300, 18 bytes
2025-10-31T16:21:44.496Z:INFO:taskCANopen.c:1821:Added object 0x3700, 132 bytes
2025-10-31T16:21:44.660Z:INFO:taskCANopen.c:1821:Added object 0x4217, 1 bytes
2025-10-31T16:21:44.824Z:INFO:taskCANopen.c:1821:Added object 0x4218, 1 bytes
2025-10-31T16:21:44.992Z:INFO:taskCANopen.c:1821:Added object 0x5217, 1 bytes
2025-10-31T16:21:45.164Z:INFO:taskCANopen.c:1821:Added object 0x5218, 1 bytes
2025-10-31T16:21:45.328Z:INFO:taskCANopen.c:1821:Added object 0x5230, 1 bytes
2025-10-31T16:22:08.042Z:INFO:taskMain.c:5996:Socket #1: Active current 0.0->16.0 due to current limit: Connector-MaxCurrent,
2025-10-31T16:22:08.042Z:INFO:taskMain.c:5996:ChargingProfile
2025-10-31T16:22:08.953Z:INFO:taskMain.c:6504:Socket #1: PP 697 Ohm (20 A)
2025-10-31T16:22:08.960Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.6% (16.0 A)
2025-10-31T16:22:09.972Z:WARNING:modem.c:2725:AT+CSQ, invalid value(99)
2025-10-31T16:22:11.789Z:USER:tag.c:1623:Reader 0 Got NFC tag: 04BB29EAFD0F94
2025-10-31T16:22:15.937Z:USER:tag.c:1623:Reader 0 Got NFC tag: 04BB29EAFD0F94
2025-10-31T16:22:19.890Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-10-31T16:22:33.929Z:INFO:taskMain.c:5996:Socket #1: Active current 16.0->0.0 due to current limit: Cable
2025-10-31T16:22:34.199Z:INFO:taskMain.c:6504:Socket #1: PP 34464 Ohm (0 A)
2025-10-31T16:22:39.117Z:INFO:taskMain.c:5996:Socket #1: Active current 0.0->16.0 due to current limit: Connector-MaxCurrent,
2025-10-31T16:22:39.117Z:INFO:taskMain.c:5996:ChargingProfile
2025-10-31T16:22:39.250Z:INFO:taskMain.c:6504:Socket #1: PP 696 Ohm (20 A)
2025-10-31T16:22:41.957Z:INFO:modem.c:3313:Signal strength : Unknown
2025-10-31T16:22:41.964Z:INFO:modem.c:3315:Radio Access Tech : 4G
2025-10-31T16:22:41.972Z:INFO:modem.c:3316:Registration mode : Disabled
2025-10-31T16:22:41.980Z:INFO:modem.c:3317:Registration status: Not registered
2025-10-31T16:22:41.988Z:INFO:modem.c:3318:Operator : 0
2025-10-31T16:22:41.996Z:INFO:modem.c:3319:Manufacturer : Quectel
2025-10-31T16:22:42.003Z:INFO:modem.c:3320:Modem module : BG95-M3
2025-10-31T16:22:42.011Z:INFO:modem.c:3321:Modem revision : BG95M3LAR02A03_01.012.01.012
2025-10-31T16:22:42.019Z:INFO:modem.c:3322:Modem IMEI : 864145067568848
2025-10-31T16:22:42.027Z:INFO:modem.c:3323:SIM IMSI :
2025-10-31T16:22:42.035Z:INFO:modem.c:3324:SIM ICCID :
2025-10-31T16:22:42.042Z:INFO:modem.c:3325:Modem supports 2G : yes
2025-10-31T16:22:42.050Z:INFO:modem.c:3326:Modem supports 3G : no
2025-10-31T16:22:42.058Z:INFO:modem.c:3327:Modem supports 4G : yes
2025-10-31T16:22:42.109Z:INFO:modem.c:3334:Cellinfo : "SEARCH"
2025-10-31T16:22:42.117Z:ERROR:modem.c:3364:Setup modem Failed
2025-10-31T16:22:42.125Z:INFO:modem.c:1124:Modem state InitModem->Stopping
2025-10-31T16:22:43.882Z:USER:tag.c:1623:Reader 0 Got NFC tag: 04BB29EAFD0F94
2025-10-31T16:22:50.648Z:INFO:modem.c:1124:Modem state Stopping->Idle
2025-10-31T16:23:30.089Z:SECURITY:httpd_login.c:155:WebClient RadomskiR connected (account: admin)
2025-10-31T16:23:32.140Z:INFO:web_functionali:159:Executing command: 'reboot'
2025-10-31T16:23:32.277Z:SECURITY:application.c:792:reset: requested, going down..
2025-10-31T16:23:44.398Z:RESET:application.c:414:==========================================
2025-10-31T16:23:44.410Z:INFO:application.c:421:build: Oct 27 2025 13:58:28
2025-10-31T16:23:44.417Z:INFO:application.c:422:version: 7.3.0-4377
2025-10-31T16:23:44.425Z:INFO:application.c:423:compiler: gcc 9.3.1
2025-10-31T16:23:44.429Z:INFO:application.c:285:fwu state inactive
2025-10-31T16:23:44.437Z:INFO:application.c:292:Bootloader version 2.2.2
2025-10-31T16:23:44.851Z:USER:taskCANopen.c:241:Persistent configuration retrieved, 284 items
2025-10-31T16:23:44.867Z:INFO:application.c:328:FLASH read protection 0xcc level 2 (permanent)
2025-10-31T16:23:44.875Z:USER:application.c:470:Using P1 port
2025-10-31T16:23:44.882Z:INFO:application.c:364:System boot #11, cause Software reset
2025-10-31T16:23:44.890Z:INFO:board_ng9xx.c:1602:Registered timeout getHardware
2025-10-31T16:23:46.601Z:INFO:bspMotors.c:616:Socket #1: Timeout while waiting for Cover motor
2025-10-31T16:23:46.660Z:INFO:board_ng9xx.c:1629:Unregistered timeout getHardware
2025-10-31T16:23:46.667Z:INFO:application.c:510:ST MCU ID......................20036419
2025-10-31T16:23:46.679Z:INFO:application.c:511:Device ID:.....................004000203531510532353530
2025-10-31T16:23:46.687Z:INFO:application.c:512:Object ID:.....................ACE0640314
2025-10-31T16:23:46.699Z:INFO:application.c:513:#Sockets.......................1
2025-10-31T16:23:46.707Z:INFO:application.c:514:MAC address eeprom.............not available
2025-10-31T16:23:46.714Z:INFO:application.c:515:Configuration eeprom...........available
2025-10-31T16:23:46.726Z:INFO:application.c:517:Flash EEPROM...................available: manuf. 0x00c2, id 0x2016 (8 MB)
2025-10-31T16:23:46.738Z:INFO:application.c:520:Temperature sensor.............available (19.5/43.1 °C)
2025-10-31T16:23:46.750Z:INFO:application.c:521:Accelerometer/tilt sensor......not available
2025-10-31T16:23:46.757Z:INFO:application.c:522:Ambient light/proximity sensor.not available
2025-10-31T16:23:46.769Z:INFO:application.c:523:Real time clock................available
2025-10-31T16:23:46.777Z:INFO:application.c:524:Mobile network modem...........Autodetect (enabled)
2025-10-31T16:23:46.789Z:INFO:application.c:525:Ethernet PHY...................available
2025-10-31T16:23:46.996Z:INFO:application.c:534:#1 Control Pilot circuit.......available (0.6/-11.4 Volts)
2025-10-31T16:23:47.007Z:INFO:application.c:535:#1 Proximity Pin circuit.......available (698 Ohms)
2025-10-31T16:23:47.019Z:INFO:application.c:536:#1 Socket motor................available
2025-10-31T16:23:47.027Z:INFO:application.c:537:#1 Cover motor.................not available
2025-10-31T16:23:47.035Z:INFO:application.c:538:#1 Auxiliary I/O...............not available
2025-10-31T16:23:47.046Z:INFO:application.c:539:#1 Button input................not available
2025-10-31T16:23:47.054Z:INFO:application.c:540:#1 NFC reader..................not available
2025-10-31T16:23:47.066Z:INFO:application.c:541:#1 Emergency relays............available
2025-10-31T16:23:47.074Z:INFO:application.c:560:-12V power supply..............available
2025-10-31T16:23:47.085Z:INFO:application.c:561:Smart meter P1 port interface..available
2025-10-31T16:23:47.093Z:INFO:application.c:562:Smart meter Suspend input......not available
2025-10-31T16:23:47.101Z:INFO:application.c:563:Smart meter external Modbus....available
2025-10-31T16:23:47.113Z:INFO:application.c:564:Energy meter ModBus interface..available
2025-10-31T16:23:47.121Z:INFO:application.c:565:Display user interface.........available
2025-10-31T16:23:47.132Z:INFO:application.c:566:PWM Buzzer.....................not available
2025-10-31T16:23:47.140Z:INFO:application.c:569:Auxiliary Board................supported
2025-10-31T16:23:47.148Z:INFO:application.c:570:Auxiliary Board revision.......D
2025-10-31T16:23:47.160Z:INFO:application.c:572:Powerboard revision/assy.......GUNKNOWN (32.0A)
2025-10-31T16:23:47.167Z:INFO:application.c:573:Controllerboard revision/assy..L7
2025-10-31T16:23:47.175Z:INFO:application.c:574:Powerboard relay type..........LATCHING_REVERSED
2025-10-31T16:23:47.187Z:INFO:application.c:592:Operational time ..............0D 00H
2025-10-31T16:23:47.203Z:INFO:db_common.c:147:Initializing all databases..
2025-10-31T16:23:47.628Z:INFO:db_base.c:1325:Initialized Transaction db (firstItem=0x00000000, lastItem=0x00001877)
2025-10-31T16:23:47.644Z:INFO:db_base.c:1325:Initialized LocalList db (firstItem=0x00000000, lastItem=0x00000000)
2025-10-31T16:23:47.660Z:INFO:db_base.c:1325:Initialized WhiteList db (firstItem=0x00000000, lastItem=0x00000041)
2025-10-31T16:23:47.675Z:INFO:db_base.c:1325:Initialized ChargingProfile db (firstItem=0x00000000, lastItem=0x000001b1)
2025-10-31T16:23:47.707Z:INFO:db_chargingprofi:75:Defragmented (#0/0, 19ms)
2025-10-31T16:23:47.714Z:INFO:db_chargingprofi:19:Max 45 charging profiles of 100 periods
2025-10-31T16:23:47.726Z:INFO:db_base.c:1325:Initialized Domain db (firstItem=0x00000000, lastItem=0x00000070)
2025-10-31T16:23:47.742Z:USER:ocpp.c:187:Init OCPP for ocpp1.6
2025-10-31T16:23:47.746Z:INFO:board_ng9xx.c:1602:Registered timeout BootNotification
2025-10-31T16:23:47.785Z:INFO:featureKeys.c:78:Unlocked Features: SCN,RFID-reader,4G (80010101)
2025-10-31T16:23:47.796Z:INFO:taskMain.c:599:Socket #1: Authorisation method COM unit via CAN
2025-10-31T16:23:47.804Z:INFO:taskMain.c:602:Socket #1: SocketType Mennekes
2025-10-31T16:23:47.812Z:INFO:taskMain.c:606:Socket #1: startup delay 5 s
2025-10-31T16:23:47.824Z:INFO:board_ng9xx.c:1602:Registered timeout NUVVE
2025-10-31T16:23:47.832Z:INFO:board_ng9xx.c:1602:Registered timeout NUVVE
2025-10-31T16:23:47.847Z:USER:EVsimulator.c:210:EV simulator initialised
2025-10-31T16:23:47.855Z:USER:taskMaster.c:1050:ocpp1.6 Smart Charging Mode
2025-10-31T16:23:48.074Z:INFO:bspEthernet.c:165:Ethernet PHY LAN8710@0x00
2025-10-31T16:23:48.089Z:USER:bspEthernet.c:238:ETH PHY OK
2025-10-31T16:23:48.097Z:INFO:bspEthernet.c:217:MACAddress: [26:64:44:07:10:35]
2025-10-31T16:23:48.105Z:INFO:taskMeter.c:318:Starting smartmeter with protocol P1
2025-10-31T16:23:48.113Z:INFO:scn.c:686:Loadbalancing: Feature enabled
2025-10-31T16:23:48.121Z:INFO:scn.c:687:SCN: Feature enabled [Off]
2025-10-31T16:23:48.128Z:WARNING:scn_communicatio:75:SCN: Not enough sockets for an SCN!
2025-10-31T16:23:48.144Z:INFO:modem.c:1124:Modem state Idle->InitHw
2025-10-31T16:23:48.156Z:INFO:taskMain.c:1294:contactorstabletime : 50
2025-10-31T16:23:48.164Z:INFO:taskMain.c:1295:HFContactorSwitchTime : 60
2025-10-31T16:23:48.179Z:INFO:taskLeds.c:226:LED UI initialized OK
2025-10-31T16:23:48.187Z:INFO:taskMain.c:6180:Socket #1: DSC initialised
2025-10-31T16:23:48.195Z:INFO:station.c:184:Active station current set to 25.0A max
2025-10-31T16:23:48.210Z:INFO:taskMain.c:6504:Socket #1: PP 697 Ohm (20 A)
2025-10-31T16:23:48.218Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.0% (6.0 A)
2025-10-31T16:23:48.230Z:INFO:comConnect.c:295:Connectivity state: STARTUP
2025-10-31T16:23:48.277Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-10-31T16:23:48.781Z:INFO:taskModbus.c:4526:Address #1: modbus meter vendor : ALF
2025-10-31T16:23:48.792Z:INFO:taskModbus.c:4527:Address #1: modbus meter model : D3001
2025-10-31T16:23:48.800Z:INFO:taskModbus.c:4528:Address #1: modbus meter revision : V1.03
2025-10-31T16:23:48.812Z:INFO:taskModbus.c:4529:Address #1: modbus meter meterNumber : 22391493
2025-10-31T16:23:48.820Z:USER:taskModbus.c:936:Socket_1 Meter(1): meter type DZG_REALLIN found
2025-10-31T16:23:49.144Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:23:49.152Z:INFO:taskCANopen.c:1212:Persistent memory not cached
2025-10-31T16:23:49.164Z:INFO:taskNFCreader.c:579:Port #0 switch NFC power on
2025-10-31T16:23:49.226Z:INFO:taskMain.c:1419:Socket #1: main state: BOOTING, CP: 0.0/0.0, no tag
2025-10-31T16:23:49.257Z:INFO:taskCANopen.c:2020:CanOpen EEPROM cache size: 284, got 284 objects <284,0>
2025-10-31T16:23:49.285Z:INFO:taskCANopen.c:1787:Updated object 0x2056, 4 bytes
2025-10-31T16:23:49.316Z:USER:taskModbus.c:1107:Socket_1 Meter(1): first meter update, Multiple phase installation
2025-10-31T16:23:49.800Z:USER:bspEthernet.c:342:Mode: 100Mb/s full duplex
2025-10-31T16:23:49.808Z:INFO:taskTCPIP.c:958:Network Cable is now connected
2025-10-31T16:23:50.371Z:USER:taskMaster.c:1329:Node #1, version 7.3.0-4377
2025-10-31T16:23:50.609Z:INFO:taskTCPIP.c:1617: IP address assigned by DHCP
2025-10-31T16:23:50.617Z:INFO:taskTCPIP.c:1645:Network interface is up
2025-10-31T16:23:50.625Z:INFO:taskTCPIP.c:1654: IP : 192.168.178.184
2025-10-31T16:23:50.632Z:INFO:taskTCPIP.c:1655: Netmask : 255.255.255.0
2025-10-31T16:23:50.640Z:INFO:taskTCPIP.c:1656: Gateway : 192.168.178.1
2025-10-31T16:23:50.648Z:INFO:taskTCPIP.c:1657: DNS1 : 192.168.178.1
2025-10-31T16:23:50.656Z:INFO:taskTCPIP.c:1658: DNS2 : 208.67.220.220
2025-10-31T16:23:50.667Z:INFO:taskTCPIP.c:512:Starting mDNS on interface al
2025-10-31T16:23:50.675Z:INFO:taskTCPIP.c:512:Starting Webserver on interface al
2025-10-31T16:23:50.683Z:INFO:taskTCPIP.c:512:Starting Modbus on interface al
2025-10-31T16:23:50.691Z:INFO:taskTCPIP.c:512:Starting P1 on interface al
2025-10-31T16:23:50.699Z:INFO:taskTCPIP.c:512:Starting SCN on interface al
2025-10-31T16:23:50.707Z:INFO:taskTCPIP.c:413:default network set to 'al'
2025-10-31T16:23:50.718Z:INFO:taskWebServer.c:238:WebServer state WAIT_FOR_NETWORK -> SETUP
2025-10-31T16:23:50.753Z:USER:taskWebServer.c:360:WebServer started on port 443
2025-10-31T16:23:50.761Z:INFO:taskWebServer.c:238:WebServer state SETUP -> AVAILABLE
2025-10-31T16:23:53.191Z:INFO:comConnect.c:1107:Connecting wired to: ws://192.168.178.140:8080/steve/websocket/CentralSystemServ
2025-10-31T16:23:53.191Z:INFO:comConnect.c:1107:ice/VAN_01971, prio #1
2025-10-31T16:23:53.210Z:USER:taskMaster.c:1359:NFC version: ICU NFC 243B (v3) v3.1-531
2025-10-31T16:23:53.222Z:INFO:taskNFCreader.c:115:Port #0 version response: "ICU NFC 243B (v3) v3.1-531"
2025-10-31T16:23:53.230Z:INFO:comConnect.c:664:connection attempt 1/3
2025-10-31T16:23:53.238Z:INFO:comConnect.c:295:Connectivity state: INITIALISING
2025-10-31T16:23:53.250Z:USER:application.c:718:Initialisation done
2025-10-31T16:23:53.257Z:INFO:comConnect.c:295:Connectivity state: WIRED
2025-10-31T16:23:53.277Z:INFO:taskTCPIP.c:1526:'al' is configured as default internet connection.
2025-10-31T16:23:53.285Z:INFO:taskTCPIP.c:1543:Renew DHCP leash for interface 'al'.
2025-10-31T16:23:53.296Z:USER:comConnect.c:383:wired connect
2025-10-31T16:23:53.304Z:INFO:websockets.c:451:Connected to Socket 192.168.178.140:8080
2025-10-31T16:23:53.312Z:INFO:websockets.c:2363:WS timeout: 10000 ms
2025-10-31T16:23:53.347Z:INFO:websockets.c:824:WebSocket upgrade successful
2025-10-31T16:23:53.367Z:USER:taskOCPP.c:464:Back office connection available
2025-10-31T16:23:53.382Z:INFO:taskNFCreader.c:131:Port #0 ICU NFC reader BL3 v3.1, 1 LEDs
2025-10-31T16:23:53.390Z:INFO:taskNFCreader.c:132:Port #0 reader model: Giro-e
2025-10-31T16:23:55.453Z:INFO:modem.c:1124:Modem state InitHw->InitModem
2025-10-31T16:23:55.460Z:INFO:modem.c:1296:Reset delay 2s
2025-10-31T16:23:56.226Z:INFO:taskMaster.c:1137:Socket #1 has a Modbus meter
2025-10-31T16:23:56.234Z:INFO:updatefirmware.c:52:BL FWU_STATUS_INACTIVE -> int IDLE
2025-10-31T16:23:56.242Z:INFO:taskMain.c:1724:Socket #1: recovered INOPERATIVE
2025-10-31T16:23:56.250Z:USER:taskMaster.c:1164:1 NFC readers found
2025-10-31T16:23:56.273Z:INFO:taskMaster.c:1575:Socket #1: no open transaction
2025-10-31T16:23:56.296Z:INFO:smartMeter.c:80:Set phases: (L1, L2, L3)->(L1, L2, L3)
2025-10-31T16:23:56.304Z:INFO:active_lb.c:308:SMt:(0.0 0.0 0.0)A Free:(25.0 25.0 25.0)A ALB:(0.0 0.0 0.0)A
2025-10-31T16:23:56.316Z:INFO:taskMaster.c:4957:Socket #1: state main : INOPERATIVE
2025-10-31T16:23:56.328Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-10-31T16:23:56.335Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-10-31T16:23:56.343Z:INFO:taskMaster.c:4979:Socket #1: state led : INOPERATIVE
2025-10-31T16:23:56.402Z:INFO:taskMaster.c:6376:Socket #1: no schedule
2025-10-31T16:23:56.410Z:USER:taskMaster.c:6402:Socket #1: external current limit 16.0 A
2025-10-31T16:23:56.421Z:INFO:station.c:97:station external max - new value: 99.9A
2025-10-31T16:23:56.429Z:INFO:comFaults.c:482:Reset fault status
2025-10-31T16:23:56.437Z:USER:taskMaster.c:1359:NFC version: ICU NFC 243B (v3) v3.1-531
2025-10-31T16:23:57.265Z:INFO:taskMain.c:1419:Socket #1: main state: INOPERATIVE, CP: 0.0/0.0, no tag
2025-10-31T16:23:58.378Z:COM:ocpp_rpc.c:704:-> [2,"1","BootNotification",{"chargePointVendor":"Alfen BV","chargePointModel":
2025-10-31T16:23:58.378Z:COM:ocpp_rpc.c:704:"NG910-60583","chargePointSerialNumber":"ACE0640314","chargeBoxSerialNumber":"VA
2025-10-31T16:23:58.378Z:COM:ocpp_rpc.c:704:N_01971","firmwareVersion":"7.3.0-4377"}]
2025-10-31T16:23:58.445Z:COM:ocpp_rpc.c:1297:<- [3,"1",{"status":"Accepted","currentTime":"2025-10-31T16:23:59.202Z","interva
2025-10-31T16:23:58.445Z:COM:ocpp_rpc.c:1297:l":14400}]
2025-10-31T16:23:59.656Z:USER:modem.c:3611:Modem type: Quectel BG95-M3
2025-10-31T16:23:59.671Z:INFO:modem.c:3090:Check if modem responds
2025-10-31T16:23:59.710Z:INFO:modem.c:2977:Set flow control (on)
2025-10-31T16:23:59.824Z:INFO:taskMain.c:5996:Socket #1: Active current 0.0->8.8 due to current limit: Active-LoadBalancing
2025-10-31T16:23:59.882Z:INFO:modem.c:3130:Set type of logging
2025-10-31T16:24:00.292Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.6% (8.8 A)
2025-10-31T16:24:03.921Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:24:04.285Z:SECURITY:httpd_login.c:155:WebClient RadomskiR connected (account: admin)
2025-10-31T16:24:04.328Z:WARNING:taskWebClient.c:234:Client (fd=2) disconnected (r: -0x50)
2025-10-31T16:24:04.335Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-31T16:24:04.398Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-31T16:24:06.468Z:INFO:comFaults.c:1075:#phases: socket #1 ''->'L1L2L3'
2025-10-31T16:24:08.539Z:COM:ocpp_rpc.c:704:-> [2,"2","StatusNotification",{"connectorId":0,"errorCode":"NoError","status":"
2025-10-31T16:24:08.539Z:COM:ocpp_rpc.c:704:Unavailable"}]
2025-10-31T16:24:08.585Z:COM:ocpp_rpc.c:1297:<- [3,"2",{}]
2025-10-31T16:24:08.593Z:COM:ocpp_rpc.c:704:-> [2,"3","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":"
2025-10-31T16:24:08.593Z:COM:ocpp_rpc.c:704:Unavailable"}]
2025-10-31T16:24:08.636Z:COM:ocpp_rpc.c:1297:<- [3,"3",{}]
2025-10-31T16:24:11.824Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->14.1 due to current limit: Active-LoadBalancing
2025-10-31T16:24:12.414Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.4% (14.0 A)
2025-10-31T16:24:18.355Z:INFO:modem.c:2525:Check PIN
2025-10-31T16:24:22.132Z:WARNING:modem.c:2562:SIM error
2025-10-31T16:24:23.820Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->16.0 due to current limit: Connector-MaxCurrent,
2025-10-31T16:24:23.820Z:INFO:taskMain.c:5996: ChargingProfile
2025-10-31T16:24:24.531Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.6% (16.0 A)
2025-10-31T16:24:24.710Z:INFO:taskWifi.c:671:WiFi Module: Not Initialized --> Running
2025-10-31T16:24:26.011Z:WARNING:modem.c:2562:SIM error
2025-10-31T16:24:26.285Z:INFO:wifi.c:451:Successfully started AP <ACE0640314> ip<192.168.50.10>
2025-10-31T16:24:26.292Z:INFO:taskWifi.c:982:Start WiFi AP
2025-10-31T16:24:26.300Z:WARNING:taskWifi.c:1061:Wifi config is not valid
2025-10-31T16:24:26.308Z:INFO:taskWifi.c:678:SoftAP: Not Initialized --> Enabled
2025-10-31T16:24:26.316Z:INFO:taskWifi.c:685:STA: Not Initialized --> Not Configured
2025-10-31T16:24:29.886Z:WARNING:modem.c:2562:SIM error
2025-10-31T16:24:33.765Z:WARNING:modem.c:2562:SIM error
2025-10-31T16:24:33.871Z:INFO:modem.c:2572:Check PIN failed
2025-10-31T16:24:43.058Z:INFO:taskMain.c:5996:Socket #1: Active current 16.0->0.0 due to current limit: Cable
2025-10-31T16:24:43.718Z:INFO:taskMain.c:6504:Socket #1: PP 34464 Ohm (0 A)
2025-10-31T16:24:48.652Z:INFO:modem.c:3291:Get other info
2025-10-31T16:24:59.859Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:24:59.917Z:SECURITY:taskWebClient.c:446:Received unauthorized request, so removing client
2025-10-31T16:24:59.929Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-31T16:24:59.988Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-31T16:25:01.746Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:25:02.386Z:SECURITY:httpd_login.c:155:WebClient RadomskiR connected (account: admin)
2025-10-31T16:25:21.761Z:WARNING:modem.c:2725:AT+CSQ, invalid value(99)
2025-10-31T16:25:53.742Z:INFO:modem.c:3313:Signal strength : Unknown
2025-10-31T16:25:53.750Z:INFO:modem.c:3315:Radio Access Tech : 4G
2025-10-31T16:25:53.761Z:INFO:modem.c:3316:Registration mode : Disabled
2025-10-31T16:25:53.769Z:INFO:modem.c:3317:Registration status: Not registered
2025-10-31T16:25:53.777Z:INFO:modem.c:3318:Operator : 0
2025-10-31T16:25:53.785Z:INFO:modem.c:3319:Manufacturer : Quectel
2025-10-31T16:25:53.792Z:INFO:modem.c:3320:Modem module : BG95-M3
2025-10-31T16:25:53.800Z:INFO:modem.c:3321:Modem revision : BG95M3LAR02A03_01.012.01.012
2025-10-31T16:25:53.812Z:INFO:modem.c:3322:Modem IMEI : 864145067568848
2025-10-31T16:25:53.820Z:INFO:modem.c:3323:SIM IMSI :
2025-10-31T16:25:53.828Z:INFO:modem.c:3324:SIM ICCID :
2025-10-31T16:25:53.832Z:INFO:modem.c:3325:Modem supports 2G : yes
2025-10-31T16:25:53.839Z:INFO:modem.c:3326:Modem supports 3G : no
2025-10-31T16:25:53.847Z:INFO:modem.c:3327:Modem supports 4G : yes
2025-10-31T16:25:53.898Z:INFO:modem.c:3334:Cellinfo : "SEARCH"
2025-10-31T16:25:53.906Z:ERROR:modem.c:3364:Setup modem Failed
2025-10-31T16:25:53.914Z:INFO:modem.c:1124:Modem state InitModem->Stopping
2025-10-31T16:26:02.433Z:INFO:modem.c:1124:Modem state Stopping->Idle
2025-10-31T16:26:07.226Z:COM:ocpp_rpc.c:1297:<- [2,"8892fb2f-74fc-41e3-b4a2-50269f62c611","GetConfiguration",{"key":[]}]
2025-10-31T16:26:07.238Z:COM:ocpp_rpc.c:760:-> [3,"8892fb2f-74fc-41e3-b4a2-50269f62c611",{"configurationKey":[
2025-10-31T16:26:07.250Z:COM:ocpp_rpc.c:760:-> {"key":"FeatureObjectId","readonly":true,"value":"ACE0640314"}
2025-10-31T16:26:07.261Z:COM:ocpp_rpc.c:760:-> ,{"key":"Identity","readonly":false,"value":"VAN_01971"}
2025-10-31T16:26:07.273Z:COM:ocpp_rpc.c:760:-> ,{"key":"DeviceIdentifier","readonly":true,"value":"004000203531510532353530"
2025-10-31T16:26:07.273Z:COM:ocpp_rpc.c:760:}
2025-10-31T16:26:07.289Z:COM:ocpp_rpc.c:760:-> ,{"key":"FeatureLicenseKey","readonly":false,"value":"3180.1401.C001.5E01.597
2025-10-31T16:26:07.289Z:COM:ocpp_rpc.c:760:5.365B"}
2025-10-31T16:26:07.308Z:COM:ocpp_rpc.c:760:-> ,{"key":"UnlockedFeatures","readonly":true,"value":"SCN,RFID-reader,4G"}
2025-10-31T16:26:07.324Z:COM:ocpp_rpc.c:760:-> ,{"key":"SupportedFeatureProfiles","readonly":true,"value":"Core,FirmwareMana
2025-10-31T16:26:07.324Z:COM:ocpp_rpc.c:760:gement,Reservation,LocalAuthListManagement,RemoteTrigger,SmartCharging"}
2025-10-31T16:26:07.347Z:COM:ocpp_rpc.c:760:-> ,{"key":"SupportedFeatureProfilesMaxLength","readonly":true,"value":"6"}
2025-10-31T16:26:07.359Z:COM:ocpp_rpc.c:760:-> ,{"key":"TimeZoneMinutes","readonly":false,"value":"60"}
2025-10-31T16:26:07.371Z:COM:ocpp_rpc.c:760:-> ,{"key":"Latitude","readonly":false,"value":"52.402271"}
2025-10-31T16:26:07.382Z:COM:ocpp_rpc.c:760:-> ,{"key":"Longitude","readonly":false,"value":"5.243745"}
2025-10-31T16:26:07.394Z:COM:ocpp_rpc.c:760:-> ,{"key":"Bootloader-Version","readonly":true,"value":"2.2.2"}
2025-10-31T16:26:07.406Z:COM:ocpp_rpc.c:760:-> ,{"key":"NFC-Version1","readonly":true,"value":"HW:243B,SW:3.1-531"}
2025-10-31T16:26:07.417Z:COM:ocpp_rpc.c:760:-> ,{"key":"Station-MaxCurrent","readonly":false,"value":"25.0"}
2025-10-31T16:26:07.429Z:COM:ocpp_rpc.c:760:-> ,{"key":"Connector1-MaxCurrent","readonly":false,"value":"16.0"}
2025-10-31T16:26:07.441Z:COM:ocpp_rpc.c:760:-> ,{"key":"Connector1-Type","readonly":true,"value":"Type 2 socket"}
2025-10-31T16:26:07.453Z:COM:ocpp_rpc.c:760:-> ,{"key":"ZE-ready","readonly":false,"value":"False"}
2025-10-31T16:26:07.464Z:COM:ocpp_rpc.c:760:-> ,{"key":"Power Outage Recovery","readonly":false,"value":"Idle"}
2025-10-31T16:26:07.476Z:COM:ocpp_rpc.c:760:-> ,{"key":"Max Allowed Outage Duration (s)","readonly":false,"value":"0"}
2025-10-31T16:26:07.488Z:COM:ocpp_rpc.c:760:-> ,{"key":"Disable105Percent","readonly":false,"value":"False"}
2025-10-31T16:26:07.500Z:COM:ocpp_rpc.c:760:-> ,{"key":"Chameleon-MinCurrent","readonly":false,"value":"14.0"}
2025-10-31T16:26:07.515Z:COM:ocpp_rpc.c:760:-> ,{"key":"ConnectionTimeOut","readonly":false,"value":"120"}
2025-10-31T16:26:07.527Z:COM:ocpp_rpc.c:760:-> ,{"key":"AuthorizationTimeOut","readonly":false,"value":"120"}
2025-10-31T16:26:07.539Z:COM:ocpp_rpc.c:760:-> ,{"key":"Phase-Connected","readonly":false,"value":"L1L2L3"}
2025-10-31T16:26:07.550Z:COM:ocpp_rpc.c:760:-> ,{"key":"RandomisedDelay","readonly":false,"value":"0"}
2025-10-31T16:26:07.562Z:COM:ocpp_rpc.c:760:-> ,{"key":"Static-LoadBalancing","readonly":false,"value":"On"}
2025-10-31T16:26:07.574Z:COM:ocpp_rpc.c:760:-> ,{"key":"Active-LoadBalancing","readonly":false,"value":"On"}
2025-10-31T16:26:07.585Z:COM:ocpp_rpc.c:760:-> ,{"key":"ALB-ProtocolSelection","readonly":false,"value":"DSMR P1"}
2025-10-31T16:26:07.597Z:COM:ocpp_rpc.c:760:-> ,{"key":"RJ11-Mode","readonly":false,"value":"DSMR P1"}
2025-10-31T16:26:07.609Z:COM:ocpp_rpc.c:760:-> ,{"key":"MBTCPSmart-IPAddress","readonly":false,"value":"192.168.000.004"}
2025-10-31T16:26:07.621Z:COM:ocpp_rpc.c:760:-> ,{"key":"MBTCPSmart-Port","readonly":false,"value":"502"}
2025-10-31T16:26:07.632Z:COM:ocpp_rpc.c:760:-> ,{"key":"MBTCPSmart-IsEnabled","readonly":false,"value":"False"}
2025-10-31T16:26:07.644Z:COM:ocpp_rpc.c:760:-> ,{"key":"MBTCPSmart-SlaveUnitID","readonly":false,"value":"5"}
2025-10-31T16:26:07.656Z:COM:ocpp_rpc.c:760:-> ,{"key":"MBTCPSmart-SlaveMeterModel","readonly":false,"value":"Socomec"}
2025-10-31T16:26:07.671Z:COM:ocpp_rpc.c:760:-> ,{"key":"MbsSlaveTCPIP","readonly":false,"value":"Off"}
2025-10-31T16:26:07.683Z:COM:ocpp_rpc.c:760:-> ,{"key":"MbsSlaveTCPIPValidityTime","readonly":false,"value":"60"}
2025-10-31T16:26:07.695Z:COM:ocpp_rpc.c:760:-> ,{"key":"MbsSlaveTCPIPMode","readonly":false,"value":"Off"}
2025-10-31T16:26:07.707Z:COM:ocpp_rpc.c:760:-> ,{"key":"Safe-MaxCurrent","readonly":false,"value":"16.0"}
2025-10-31T16:26:07.718Z:COM:ocpp_rpc.c:760:-> ,{"key":"SCN-AlternatingPeriod","readonly":false,"value":"900"}
2025-10-31T16:26:07.730Z:COM:ocpp_rpc.c:760:-> ,{"key":"SCN-IsEnabled","readonly":true,"value":"True"}
2025-10-31T16:26:07.742Z:COM:ocpp_rpc.c:760:-> ,{"key":"SCN-NetworkName","readonly":false,"value":""}
2025-10-31T16:26:07.750Z:COM:ocpp_rpc.c:760:-> ,{"key":"SCN-PhaseMapping-1","readonly":false,"value":"4"}
2025-10-31T16:26:07.765Z:COM:ocpp_rpc.c:760:-> ,{"key":"SCN-SocketSafeCurrent","readonly":false,"value":"6.000000"}
2025-10-31T16:26:07.777Z:COM:ocpp_rpc.c:760:-> ,{"key":"SCN-TotalSafeCurrent","readonly":false,"value":"32.000000"}
2025-10-31T16:26:07.789Z:COM:ocpp_rpc.c:760:-> ,{"key":"SCN-SocketCount","readonly":false,"value":"1"}
2025-10-31T16:26:07.800Z:COM:ocpp_rpc.c:760:-> ,{"key":"SCN-SocketID","readonly":false,"value":"0"}
2025-10-31T16:26:07.812Z:COM:ocpp_rpc.c:760:-> ,{"key":"SCN-TotalStaticCurrent","readonly":false,"value":"200.000000"}
2025-10-31T16:26:07.824Z:COM:ocpp_rpc.c:760:-> ,{"key":"ChargeProfileMaxStackLevel","readonly":true,"value":"15"}
2025-10-31T16:26:07.839Z:COM:ocpp_rpc.c:760:-> ,{"key":"ChargingScheduleAllowedChargingRateUnit","readonly":true,"value":"Cu
2025-10-31T16:26:07.839Z:COM:ocpp_rpc.c:760:rrent"}
2025-10-31T16:26:07.859Z:COM:ocpp_rpc.c:760:-> ,{"key":"ChargingScheduleMaxPeriods","readonly":true,"value":"100"}
2025-10-31T16:26:07.875Z:COM:ocpp_rpc.c:760:-> ,{"key":"MaxChargingProfilesInstalled","readonly":true,"value":"45"}
2025-10-31T16:26:07.886Z:COM:ocpp_rpc.c:760:-> ,{"key":"ConnectorSwitch3to1PhaseSupported","readonly":true,"value":"True"}
2025-10-31T16:26:07.898Z:COM:ocpp_rpc.c:760:-> ,{"key":"ConnectorPhaseRotation","readonly":false,"value":"0.RST"}
2025-10-31T16:26:07.914Z:COM:ocpp_rpc.c:760:-> ,{"key":"ConnectorPhaseRotationMaxLength","readonly":true,"value":"0"}
2025-10-31T16:26:07.925Z:COM:ocpp_rpc.c:760:-> ,{"key":"SmartMeter-MaxCurrent","readonly":false,"value":"25.0"}
2025-10-31T16:26:07.937Z:COM:ocpp_rpc.c:760:-> ,{"key":"SmartMeterIncludesCharger","readonly":false,"value":"True"}
2025-10-31T16:26:07.949Z:COM:ocpp_rpc.c:760:-> ,{"key":"MBTCPCentral-IPAddress","readonly":false,"value":"192.168.000.004"}
2025-10-31T16:26:07.964Z:COM:ocpp_rpc.c:760:-> ,{"key":"MBTCPCentral-Port","readonly":false,"value":"502"}
2025-10-31T16:26:07.976Z:COM:ocpp_rpc.c:760:-> ,{"key":"MBTCPCentral-IsEnabled","readonly":false,"value":"False"}
2025-10-31T16:26:07.988Z:COM:ocpp_rpc.c:760:-> ,{"key":"MBTCPCentral-SlaveUnitID","readonly":false,"value":"5"}
2025-10-31T16:26:08.000Z:COM:ocpp_rpc.c:760:-> ,{"key":"MBTCPCentral-SlaveMeterModel","readonly":false,"value":"Socomec"}
2025-10-31T16:26:08.015Z:COM:ocpp_rpc.c:760:-> ,{"key":"EnablePhaseSwitching","readonly":false,"value":"True"}
2025-10-31T16:26:08.027Z:COM:ocpp_rpc.c:760:-> ,{"key":"MaxImbalanceCurrent","readonly":false,"value":"0.000000"}
2025-10-31T16:26:08.039Z:COM:ocpp_rpc.c:760:-> ,{"key":"MaxAllowedPhases","readonly":false,"value":"3"}
2025-10-31T16:26:08.046Z:COM:ocpp_rpc.c:760:-> ,{"key":"SC-Mode","readonly":false,"value":"Off"}
2025-10-31T16:26:08.058Z:COM:ocpp_rpc.c:760:-> ,{"key":"SC-GreenShare","readonly":false,"value":"25"}
2025-10-31T16:26:08.070Z:COM:ocpp_rpc.c:760:-> ,{"key":"SC-ComfortLevel","readonly":false,"value":"1400"}
2025-10-31T16:26:08.082Z:COM:ocpp_rpc.c:760:-> ,{"key":"DisconnectAction","readonly":false,"value":"Unlock"}
2025-10-31T16:26:08.093Z:COM:ocpp_rpc.c:760:-> ,{"key":"UnlockConnectorOnEVSideDisconnect","readonly":false,"value":"True"}
2025-10-31T16:26:08.109Z:COM:ocpp_rpc.c:760:-> ,{"key":"DisconnectTimeout","readonly":false,"value":"60"}
2025-10-31T16:26:08.121Z:COM:ocpp_rpc.c:760:-> ,{"key":"AbortConcurrentTx","readonly":false,"value":"False"}
2025-10-31T16:26:08.132Z:COM:ocpp_rpc.c:760:-> ,{"key":"AllowOfflineTxForUnknownId","readonly":false,"value":"True"}
2025-10-31T16:26:08.144Z:COM:ocpp_rpc.c:760:-> ,{"key":"AuthorizationCacheEnabled","readonly":false,"value":"True"}
2025-10-31T16:26:08.156Z:COM:ocpp_rpc.c:760:-> ,{"key":"AuthorizationMethod","readonly":false,"value":"RFID"}
2025-10-31T16:26:08.167Z:COM:ocpp_rpc.c:760:-> ,{"key":"AuthorizeRemoteTxRequests","readonly":false,"value":"False"}
2025-10-31T16:26:08.179Z:COM:ocpp_rpc.c:760:-> ,{"key":"LocalAuthListEnabled","readonly":false,"value":"True"}
2025-10-31T16:26:08.191Z:COM:ocpp_rpc.c:760:-> ,{"key":"LocalAuthListMaxLength","readonly":true,"value":"424"}
2025-10-31T16:26:08.203Z:COM:ocpp_rpc.c:760:-> ,{"key":"LocalAuthorizeOffline","readonly":false,"value":"True"}
2025-10-31T16:26:08.214Z:COM:ocpp_rpc.c:760:-> ,{"key":"LocalPreAuthorize","readonly":false,"value":"True"}
2025-10-31T16:26:08.230Z:COM:ocpp_rpc.c:760:-> ,{"key":"PlugAndChargeIdentifier","readonly":false,"value":""}
2025-10-31T16:26:08.242Z:COM:ocpp_rpc.c:760:-> ,{"key":"WhiteListEnabled","readonly":false,"value":"True"}
2025-10-31T16:26:08.253Z:COM:ocpp_rpc.c:760:-> ,{"key":"MaxEnergyOnInvalidId","readonly":false,"value":"0"}
2025-10-31T16:26:08.265Z:COM:ocpp_rpc.c:760:-> ,{"key":"SendLocalListMaxLength","readonly":true,"value":"46"}
2025-10-31T16:26:08.277Z:COM:ocpp_rpc.c:760:-> ,{"key":"StopTransactionOnEVSideDisconnect","readonly":false,"value":"True"}
2025-10-31T16:26:08.289Z:COM:ocpp_rpc.c:760:-> ,{"key":"TimeUnlockWhenNotCharging","readonly":false,"value":"0"}
2025-10-31T16:26:08.300Z:COM:ocpp_rpc.c:760:-> ,{"key":"StopTransactionOnInvalidId","readonly":false,"value":"False"}
2025-10-31T16:26:08.316Z:COM:ocpp_rpc.c:760:-> ,{"key":"MasterKey-isEnabled","readonly":false,"value":"False"}
2025-10-31T16:26:08.328Z:COM:ocpp_rpc.c:760:-> ,{"key":"MasterKey-Id","readonly":false,"value":""}
2025-10-31T16:26:08.335Z:COM:ocpp_rpc.c:760:-> ,{"key":"MasterPassGroupId","readonly":false,"value":"
2025-10-31T16:26:08.335Z:COM:ocpp_rpc.c:760: "}
2025-10-31T16:26:08.359Z:COM:ocpp_rpc.c:760:-> ,{"key":"TransactionMessageAttempts","readonly":false,"value":"0"}
2025-10-31T16:26:08.371Z:COM:ocpp_rpc.c:760:-> ,{"key":"TransactionMessageRetryInterval","readonly":false,"value":"60"}
2025-10-31T16:26:08.382Z:COM:ocpp_rpc.c:760:-> ,{"key":"WebSocketPingInterval","readonly":false,"value":"120"}
2025-10-31T16:26:08.394Z:COM:ocpp_rpc.c:760:-> ,{"key":"APN-SignalStrength","readonly":true,"value":"0"}
2025-10-31T16:26:08.406Z:COM:ocpp_rpc.c:760:-> ,{"key":"AuthorizationKey","readonly":false,"value":""}
2025-10-31T16:26:08.417Z:COM:ocpp_rpc.c:760:-> ,{"key":"DNS-1","readonly":false,"value":""}
2025-10-31T16:26:08.425Z:COM:ocpp_rpc.c:760:-> ,{"key":"DNS-2","readonly":false,"value":""}
2025-10-31T16:26:08.437Z:COM:ocpp_rpc.c:760:-> ,{"key":"CentralMeterValueAlignment","readonly":false,"value":"clock"}
2025-10-31T16:26:08.449Z:COM:ocpp_rpc.c:760:-> ,{"key":"CentralMeterValueSampleInterval","readonly":false,"value":"900"}
2025-10-31T16:26:08.464Z:COM:ocpp_rpc.c:760:-> ,{"key":"CentralMeterValueTransmissionMode","readonly":false,"value":"during"
2025-10-31T16:26:08.464Z:COM:ocpp_rpc.c:760:}
2025-10-31T16:26:08.484Z:COM:ocpp_rpc.c:760:-> ,{"key":"HeartbeatInterval","readonly":false,"value":"14400"}
2025-10-31T16:26:08.496Z:COM:ocpp_rpc.c:760:-> ,{"key":"HeartBeatSendAllways","readonly":false,"value":"False"}
2025-10-31T16:26:08.507Z:COM:ocpp_rpc.c:760:-> ,{"key":"MaxTxMeterValueRandomisationTime","readonly":false,"value":"0"}
2025-10-31T16:26:08.519Z:COM:ocpp_rpc.c:760:-> ,{"key":"ClockAlignedDataInterval","readonly":false,"value":"0"}
2025-10-31T16:26:08.531Z:COM:ocpp_rpc.c:760:-> ,{"key":"MeterValuesAlignedData","readonly":false,"value":""}
2025-10-31T16:26:08.542Z:COM:ocpp_rpc.c:760:-> ,{"key":"MeterValuesAlignedDataMaxLength","readonly":true,"value":"9"}
2025-10-31T16:26:08.558Z:COM:ocpp_rpc.c:760:-> ,{"key":"MeterValueSampleInterval","readonly":false,"value":"900"}
2025-10-31T16:26:08.570Z:COM:ocpp_rpc.c:760:-> ,{"key":"MeterValuesSampledData","readonly":false,"value":"Energy.Active.Impo
2025-10-31T16:26:08.570Z:COM:ocpp_rpc.c:760:rt.Register"}
2025-10-31T16:26:08.589Z:COM:ocpp_rpc.c:760:-> ,{"key":"MeterValuesSampledDataMaxLength","readonly":true,"value":"9"}
2025-10-31T16:26:08.601Z:COM:ocpp_rpc.c:760:-> ,{"key":"StopTxnAlignedData","readonly":false,"value":"Energy.Active.Import.R
2025-10-31T16:26:08.601Z:COM:ocpp_rpc.c:760:egister"}
2025-10-31T16:26:08.621Z:COM:ocpp_rpc.c:760:-> ,{"key":"StopTxnAlignedDataMaxLength","readonly":true,"value":"0"}
2025-10-31T16:26:08.632Z:COM:ocpp_rpc.c:760:-> ,{"key":"StopTxnSampledData","readonly":false,"value":"Energy.Active.Import.R
2025-10-31T16:26:08.632Z:COM:ocpp_rpc.c:760:egister"}
2025-10-31T16:26:08.656Z:COM:ocpp_rpc.c:760:-> ,{"key":"StopTxnSampledDataMaxLength","readonly":true,"value":"0"}
2025-10-31T16:26:08.667Z:COM:ocpp_rpc.c:760:-> ,{"key":"ProxyEnable","readonly":false,"value":"False"}
2025-10-31T16:26:08.679Z:COM:ocpp_rpc.c:760:-> ,{"key":"ProxyAddressAndPort","readonly":false,"value":""}
2025-10-31T16:26:08.691Z:COM:ocpp_rpc.c:760:-> ,{"key":"ProxyUsername","readonly":false,"value":""}
2025-10-31T16:26:08.703Z:COM:ocpp_rpc.c:760:-> ,{"key":"SupportedFileTransferProtocols","readonly":true,"value":"FTP"}
2025-10-31T16:26:08.714Z:COM:ocpp_rpc.c:760:-> ,{"key":"OCPPStackVersion","readonly":true,"value":"7.1"}
2025-10-31T16:26:08.726Z:COM:ocpp_rpc.c:760:-> ,{"key":"MobileNetworkPreference","readonly":false,"value":"4G"}
2025-10-31T16:26:08.738Z:COM:ocpp_rpc.c:760:-> ,{"key":"MobileNetworkSelection","readonly":false,"value":"auto"}
2025-10-31T16:26:08.750Z:COM:ocpp_rpc.c:760:-> ,{"key":"ModemManufacturer","readonly":true,"value":"Quectel"}
2025-10-31T16:26:08.761Z:COM:ocpp_rpc.c:760:-> ,{"key":"ModemModel","readonly":true,"value":"BG95-M3"}
2025-10-31T16:26:08.773Z:COM:ocpp_rpc.c:760:-> ,{"key":"ModemRevision","readonly":true,"value":"BG95M3LAR02A03_01.012.01.012
2025-10-31T16:26:08.773Z:COM:ocpp_rpc.c:760:"}
2025-10-31T16:26:08.792Z:COM:ocpp_rpc.c:760:-> ,{"key":"RegisterMeterValuesIncludePhases","readonly":false,"value":"False"}
2025-10-31T16:26:08.804Z:COM:ocpp_rpc.c:760:-> ,{"key":"BackOfficeNetworkProfile1","readonly":false,"value":"ocppVersion{OCP
2025-10-31T16:26:08.804Z:COM:ocpp_rpc.c:760:P16}ocppCsmsUrl{ws://192.168.178.140:8080/steve/websocket/CentralSystemService}m
2025-10-31T16:26:08.804Z:COM:ocpp_rpc.c:760:essageTimeout{10}securityProfile{0}ocppInterface{Wired0}"}
2025-10-31T16:26:08.847Z:COM:ocpp_rpc.c:760:-> ,{"key":"BackOfficeNetworkProfile2","readonly":false,"value":"ocppVersion{OCP
2025-10-31T16:26:08.847Z:COM:ocpp_rpc.c:760:P12}ocppCsmsUrl{}messageTimeout{10}securityProfile{0}ocppInterface{}"}
2025-10-31T16:26:08.875Z:COM:ocpp_rpc.c:760:-> ,{"key":"BackOfficeNetworkProfile3","readonly":false,"value":"ocppVersion{OCP
2025-10-31T16:26:08.875Z:COM:ocpp_rpc.c:760:P12}ocppCsmsUrl{}messageTimeout{10}securityProfile{0}ocppInterface{}"}
2025-10-31T16:26:08.898Z:COM:ocpp_rpc.c:760:-> ,{"key":"BackOfficeNetworkProfile4","readonly":false,"value":"ocppVersion{OCP
2025-10-31T16:26:08.898Z:COM:ocpp_rpc.c:760:P12}ocppCsmsUrl{}messageTimeout{10}securityProfile{0}ocppInterface{}"}
2025-10-31T16:26:08.925Z:COM:ocpp_rpc.c:760:-> ,{"key":"NetworkConfigurationPriority","readonly":false,"value":"1"}
2025-10-31T16:26:08.937Z:COM:ocpp_rpc.c:760:-> ,{"key":"NetworkProfileConnectionAttempts","readonly":false,"value":"3"}
2025-10-31T16:26:08.949Z:COM:ocpp_rpc.c:760:-> ,{"key":"MinimumStatusDuration","readonly":false,"value":"0"}
2025-10-31T16:26:08.964Z:COM:ocpp_rpc.c:760:-> ,{"key":"StatusNotificationMode","readonly":false,"value":"Normal"}
2025-10-31T16:26:08.976Z:COM:ocpp_rpc.c:760:-> ,{"key":"AutoDimLights","readonly":false,"value":"time"}
2025-10-31T16:26:08.988Z:COM:ocpp_rpc.c:760:-> ,{"key":"LightIntensity","readonly":false,"value":"100"}
2025-10-31T16:26:09.000Z:COM:ocpp_rpc.c:760:-> ,{"key":"Language","readonly":false,"value":"en_GB"}
2025-10-31T16:26:09.011Z:COM:ocpp_rpc.c:760:-> ,{"key":"LED Heart Beat Intensity","readonly":false,"value":"100"}
2025-10-31T16:26:09.023Z:COM:ocpp_rpc.c:760:-> ,{"key":"LED Heart Beat Mode","readonly":false,"value":"Off"}
2025-10-31T16:26:09.035Z:COM:ocpp_rpc.c:760:-> ,{"key":"Cover lock enabled","readonly":false,"value":"True"}
2025-10-31T16:26:09.046Z:COM:ocpp_rpc.c:760:-> ,{"key":"NFCLEDMode","readonly":false,"value":"1"}
2025-10-31T16:26:09.058Z:COM:ocpp_rpc.c:760:-> ,{"key":"TemperatureHigh","readonly":false,"value":"100.0"}
2025-10-31T16:26:09.070Z:COM:ocpp_rpc.c:760:-> ,{"key":"TemperatureLow","readonly":false,"value":"-25.0"}
2025-10-31T16:26:09.082Z:COM:ocpp_rpc.c:760:-> ,{"key":"ContactorProtect","readonly":false,"value":"60"}
2025-10-31T16:26:09.093Z:COM:ocpp_rpc.c:760:-> ,{"key":"6mADetectResponse","readonly":false,"value":"Immediate"}
2025-10-31T16:26:09.105Z:COM:ocpp_rpc.c:760:-> ,{"key":"Connector1-ActualPower","readonly":true,"value":"0.00"}
2025-10-31T16:26:09.117Z:COM:ocpp_rpc.c:760:-> ,{"key":"Connector1-InputPhases","readonly":true,"value":"0"}
2025-10-31T16:26:09.128Z:COM:ocpp_rpc.c:760:-> ,{"key":"Connector1-OutputPhases","readonly":true,"value":"0"}
2025-10-31T16:26:09.140Z:COM:ocpp_rpc.c:760:-> ,{"key":"Connector1-PhasesConnected","readonly":true,"value":"L1L2L3"}
2025-10-31T16:26:09.152Z:COM:ocpp_rpc.c:760:-> ,{"key":"Temperature","readonly":true,"value":"25.5"}
2025-10-31T16:26:09.164Z:COM:ocpp_rpc.c:760:-> ,{"key":"StrictPEMeasurementEnabled","readonly":false,"value":"False"}
2025-10-31T16:26:09.175Z:COM:ocpp_rpc.c:760:-> ,{"key":"CertificateSignedMaxChain","readonly":true,"value":"2"}
2025-10-31T16:26:09.191Z:COM:ocpp_rpc.c:760:-> ,{"key":"CertificateStoreMaxLength","readonly":true,"value":"4"}
2025-10-31T16:26:09.203Z:COM:ocpp_rpc.c:760:-> ,{"key":"CertificateSignedMaxChainSize","readonly":true,"value":"7000"}
2025-10-31T16:26:09.214Z:COM:ocpp_rpc.c:760:-> ,{"key":"CpoName","readonly":false,"value":""}
2025-10-31T16:26:09.222Z:COM:ocpp_rpc.c:760:-> ,{"key":"PW-SetChargerPassword","readonly":false,"value":"*****"}
2025-10-31T16:26:09.238Z:COM:ocpp_rpc.c:760:-> ,{"key":"PW-SetTempAccessKey","readonly":false,"value":"*****"}
2025-10-31T16:26:09.250Z:COM:ocpp_rpc.c:760:-> ,{"key":"PW-TempAccessExpiration","readonly":false,"value":"0"}
2025-10-31T16:26:09.261Z:COM:ocpp_rpc.c:760:-> ,{"key":"PW-EndUserAccessKey","readonly":false,"value":"*****"}
2025-10-31T16:26:09.273Z:COM:ocpp_rpc.c:760:-> ,{"key":"PW-AllowSSALogin","readonly":false,"value":"True"}
2025-10-31T16:26:09.285Z:COM:ocpp_rpc.c:760:-> ,{"key":"SecurityProfile","readonly":false,"value":"0"}
2025-10-31T16:26:09.296Z:COM:ocpp_rpc.c:760:-> ,{"key":"Pricing-Currency","readonly":false,"value":"EUR"}
2025-10-31T16:26:09.308Z:COM:ocpp_rpc.c:760:-> ,{"key":"Pricing-StartPrice","readonly":false,"value":"0.000000"}
2025-10-31T16:26:09.320Z:COM:ocpp_rpc.c:760:-> ,{"key":"Pricing-EnergyPrice","readonly":false,"value":"0.000000"}
2025-10-31T16:26:09.332Z:COM:ocpp_rpc.c:760:-> ,{"key":"Pricing-MinutePrice","readonly":false,"value":"0.000000"}
2025-10-31T16:26:09.343Z:COM:ocpp_rpc.c:760:-> ,{"key":"Pricing-Other","readonly":false,"value":"0.000000"}
2025-10-31T16:26:09.355Z:COM:ocpp_rpc.c:760:-> ,{"key":"Pricing-OtherSpecifier","readonly":false,"value":""}
2025-10-31T16:26:09.367Z:COM:ocpp_rpc.c:760:-> ,{"key":"Pricing-ShowComponent","readonly":false,"value":"disclaimer"}
2025-10-31T16:26:09.382Z:COM:ocpp_rpc.c:760:-> ,{"key":"GetConfigurationMaxKeys","readonly":true,"value":"35"}
2025-10-31T16:26:09.394Z:COM:ocpp_rpc.c:760:-> ,{"key":"NumberOfConnectors","readonly":true,"value":"1"}
2025-10-31T16:26:09.406Z:COM:ocpp_rpc.c:760:-> ,{"key":"ReserveConnectorZeroSupported","readonly":true,"value":"False"}
2025-10-31T16:26:09.417Z:COM:ocpp_rpc.c:760:-> ,{"key":"ResetRetries","readonly":false,"value":"0"}
2025-10-31T16:26:09.429Z:COM:ocpp_rpc.c:760:-> ]}]
2025-10-31T16:27:05.878Z:INFO:web_functionali:159:Executing command: 'eepromx erase config'
2025-10-31T16:27:05.890Z:INFO:taskCommandLine.:23:Executing: system(eepromx erase config)
2025-10-31T16:27:05.898Z:CONSOLE:taskCommandLine.:43:eepromx erase config
2025-10-31T16:27:11.988Z:INFO:web_functionali:159:Executing command: 'reboot'
2025-10-31T16:27:12.046Z:SECURITY:application.c:792:reset: requested, going down..
2025-10-31T16:27:24.164Z:RESET:application.c:414:==========================================
2025-10-31T16:27:24.175Z:INFO:application.c:421:build: Oct 27 2025 13:58:28
2025-10-31T16:27:24.183Z:INFO:application.c:422:version: 7.3.0-4377
2025-10-31T16:27:24.187Z:INFO:application.c:423:compiler: gcc 9.3.1
2025-10-31T16:27:24.195Z:INFO:application.c:285:fwu state inactive
2025-10-31T16:27:24.203Z:INFO:application.c:292:Bootloader version 2.2.2
2025-10-31T16:27:24.210Z:USER:taskCANopen.c:241:Persistent configuration retrieved, 0 items
2025-10-31T16:27:24.226Z:INFO:application.c:328:FLASH read protection 0xcc level 2 (permanent)
2025-10-31T16:27:24.238Z:INFO:application.c:364:System boot #1, cause Software reset
2025-10-31T16:27:24.246Z:INFO:board_ng9xx.c:1602:Registered timeout getHardware
2025-10-31T16:27:25.953Z:INFO:bspMotors.c:616:Socket #1: Timeout while waiting for Cover motor
2025-10-31T16:27:26.015Z:INFO:board_ng9xx.c:1629:Unregistered timeout getHardware
2025-10-31T16:27:26.023Z:INFO:application.c:497:Restored Object Id
2025-10-31T16:27:26.031Z:INFO:application.c:510:ST MCU ID......................20036419
2025-10-31T16:27:26.039Z:INFO:application.c:511:Device ID:.....................004000203531510532353530
2025-10-31T16:27:26.050Z:INFO:application.c:512:Object ID:.....................ACE0640314
2025-10-31T16:27:26.058Z:INFO:application.c:513:#Sockets.......................1
2025-10-31T16:27:26.066Z:INFO:application.c:514:MAC address eeprom.............not available
2025-10-31T16:27:26.078Z:INFO:application.c:515:Configuration eeprom...........available
2025-10-31T16:27:26.085Z:INFO:application.c:517:Flash EEPROM...................available: manuf. 0x00c2, id 0x2016 (8 MB)
2025-10-31T16:27:26.097Z:INFO:application.c:520:Temperature sensor.............available (99.0/-99.0 °C)
2025-10-31T16:27:26.109Z:INFO:application.c:521:Accelerometer/tilt sensor......not available
2025-10-31T16:27:26.121Z:INFO:application.c:522:Ambient light/proximity sensor.not available
2025-10-31T16:27:26.128Z:INFO:application.c:523:Real time clock................available
2025-10-31T16:27:26.140Z:INFO:application.c:524:Mobile network modem...........Autodetect (enabled)
2025-10-31T16:27:26.148Z:INFO:application.c:525:Ethernet PHY...................available
2025-10-31T16:27:26.359Z:INFO:application.c:534:#1 Control Pilot circuit.......available (0.2/-11.7 Volts)
2025-10-31T16:27:26.367Z:INFO:application.c:535:#1 Proximity Pin circuit.......available (100000 Ohms)
2025-10-31T16:27:26.378Z:INFO:application.c:536:#1 Socket motor................available
2025-10-31T16:27:26.386Z:INFO:application.c:537:#1 Cover motor.................not available
2025-10-31T16:27:26.398Z:INFO:application.c:538:#1 Auxiliary I/O...............not available
2025-10-31T16:27:26.406Z:INFO:application.c:539:#1 Button input................not available
2025-10-31T16:27:26.417Z:INFO:application.c:540:#1 NFC reader..................not available
2025-10-31T16:27:26.425Z:INFO:application.c:541:#1 Emergency relays............available
2025-10-31T16:27:26.437Z:INFO:application.c:560:-12V power supply..............available
2025-10-31T16:27:26.445Z:INFO:application.c:561:Smart meter P1 port interface..available
2025-10-31T16:27:26.453Z:INFO:application.c:562:Smart meter Suspend input......not available
2025-10-31T16:27:26.464Z:INFO:application.c:563:Smart meter external Modbus....available
2025-10-31T16:27:26.472Z:INFO:application.c:564:Energy meter ModBus interface..available
2025-10-31T16:27:26.484Z:INFO:application.c:565:Display user interface.........available
2025-10-31T16:27:26.492Z:INFO:application.c:566:PWM Buzzer.....................not available
2025-10-31T16:27:26.503Z:INFO:application.c:569:Auxiliary Board................supported
2025-10-31T16:27:26.511Z:INFO:application.c:570:Auxiliary Board revision.......D
2025-10-31T16:27:26.519Z:INFO:application.c:572:Powerboard revision/assy.......GUNKNOWN (32.0A)
2025-10-31T16:27:26.531Z:INFO:application.c:573:Controllerboard revision/assy..L7
2025-10-31T16:27:26.539Z:INFO:application.c:574:Powerboard relay type..........LATCHING_REVERSED
2025-10-31T16:27:26.546Z:INFO:application.c:592:Operational time ..............0D 00H
2025-10-31T16:27:26.562Z:INFO:db_common.c:147:Initializing all databases..
2025-10-31T16:27:26.988Z:INFO:db_base.c:1325:Initialized Transaction db (firstItem=0x00000000, lastItem=0x00001877)
2025-10-31T16:27:27.003Z:INFO:db_base.c:1325:Initialized LocalList db (firstItem=0x00000000, lastItem=0x00000000)
2025-10-31T16:27:27.019Z:INFO:db_base.c:1325:Initialized WhiteList db (firstItem=0x00000000, lastItem=0x00000041)
2025-10-31T16:27:27.035Z:INFO:db_base.c:1325:Initialized ChargingProfile db (firstItem=0x00000000, lastItem=0x000001b1)
2025-10-31T16:27:27.066Z:INFO:db_chargingprofi:75:Defragmented (#0/0, 19ms)
2025-10-31T16:27:27.074Z:INFO:db_chargingprofi:19:Max 45 charging profiles of 100 periods
2025-10-31T16:27:27.082Z:INFO:db_base.c:1325:Initialized Domain db (firstItem=0x00000000, lastItem=0x00000070)
2025-10-31T16:27:27.101Z:INFO:board_ng9xx.c:1602:Registered timeout BootNotification
2025-10-31T16:27:27.109Z:INFO:featureKeys.c:83:No features unlocked
2025-10-31T16:27:27.117Z:WARNING:featureKeys.c:370:Static Loadbalancing feature is not supported! Resetting property 2064
2025-10-31T16:27:27.128Z:WARNING:featureKeys.c:385:RFID reader feature is not supported! Resetting property 2126
2025-10-31T16:27:27.140Z:WARNING:featureKeys.c:413:Resetting Plug&Charge ID to A0640314
2025-10-31T16:27:27.175Z:SECURITY:featureKeys.c:278:LicenseKeyUpdated
2025-10-31T16:27:27.183Z:INFO:taskMain.c:599:Socket #1: Authorisation method Plug&Charge
2025-10-31T16:27:27.195Z:INFO:taskMain.c:602:Socket #1: SocketType Mennekes
2025-10-31T16:27:27.203Z:INFO:taskMain.c:606:Socket #1: startup delay 5 s
2025-10-31T16:27:27.214Z:INFO:board_ng9xx.c:1602:Registered timeout NUVVE
2025-10-31T16:27:27.222Z:INFO:board_ng9xx.c:1602:Registered timeout NUVVE
2025-10-31T16:27:27.238Z:USER:EVsimulator.c:210:EV simulator initialised
2025-10-31T16:27:27.246Z:USER:taskMaster.c:1054:local Smart Charging Mode
2025-10-31T16:27:27.253Z:INFO:taskMaster.c:1066:Initialized OD_sensTemperatureAlarmHigh to 100.0
2025-10-31T16:27:27.468Z:INFO:bspEthernet.c:165:Ethernet PHY LAN8710@0x00
2025-10-31T16:27:27.488Z:USER:bspEthernet.c:238:ETH PHY OK
2025-10-31T16:27:27.492Z:INFO:bspEthernet.c:217:MACAddress: [26:64:44:07:10:35]
2025-10-31T16:27:27.500Z:INFO:modem.c:1124:Modem state Idle->InitHw
2025-10-31T16:27:27.507Z:INFO:scn.c:686:Loadbalancing: Feature locked!
2025-10-31T16:27:27.515Z:INFO:scn.c:687:SCN: Feature locked! [Off]
2025-10-31T16:27:27.523Z:WARNING:scn_communicatio:75:SCN: Not enough sockets for an SCN!
2025-10-31T16:27:27.535Z:INFO:taskMain.c:1294:contactorstabletime : 50
2025-10-31T16:27:27.546Z:INFO:taskMain.c:1295:HFContactorSwitchTime : 60
2025-10-31T16:27:27.558Z:INFO:taskLeds.c:226:LED UI initialized OK
2025-10-31T16:27:27.566Z:INFO:taskMain.c:6180:Socket #1: DSC initialised
2025-10-31T16:27:27.574Z:INFO:station.c:184:Active station current set to 16.0A max
2025-10-31T16:27:27.585Z:INFO:taskMain.c:6504:Socket #1: PP 34464 Ohm (0 A)
2025-10-31T16:27:27.593Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.0% (6.0 A)
2025-10-31T16:27:27.601Z:INFO:comConnect.c:295:Connectivity state: STARTUP
2025-10-31T16:27:27.609Z:USER:application.c:718:Initialisation done
2025-10-31T16:27:27.660Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-10-31T16:27:28.519Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:27:28.527Z:INFO:taskCANopen.c:1212:Persistent memory not cached
2025-10-31T16:27:28.539Z:INFO:taskNFCreader.c:579:Port #0 switch NFC power on
2025-10-31T16:27:28.546Z:INFO:taskCANopen.c:2020:CanOpen EEPROM cache size: 284, got 0 objects <0,0>
2025-10-31T16:27:28.566Z:INFO:taskCANopen.c:1821:Added object 0x204f, 2 bytes
2025-10-31T16:27:28.585Z:INFO:taskCANopen.c:1821:Added object 0x2050, 21 bytes
2025-10-31T16:27:28.593Z:INFO:taskMain.c:1419:Socket #1: main state: BOOTING, CP: 0.0/0.0, no tag
2025-10-31T16:27:28.605Z:INFO:taskCANopen.c:1821:Added object 0x2051, 26 bytes
2025-10-31T16:27:28.636Z:INFO:taskCANopen.c:1821:Added object 0x2052, 23 bytes
2025-10-31T16:27:28.656Z:INFO:taskCANopen.c:1821:Added object 0x2053, 21 bytes
2025-10-31T16:27:28.683Z:INFO:taskCANopen.c:1821:Added object 0x2055, 21 bytes
2025-10-31T16:27:28.707Z:INFO:taskCANopen.c:1821:Added object 0x2056, 4 bytes
2025-10-31T16:27:28.730Z:INFO:taskCANopen.c:1821:Added object 0x2057, 51 bytes
2025-10-31T16:27:28.753Z:INFO:taskCANopen.c:1821:Added object 0x205a, 1 bytes
2025-10-31T16:27:28.777Z:INFO:taskCANopen.c:1821:Added object 0x205b, 1 bytes
2025-10-31T16:27:28.800Z:INFO:taskCANopen.c:1821:Added object 0x205c, 8 bytes
2025-10-31T16:27:28.824Z:INFO:taskCANopen.c:1821:Added object 0x205d, 9 bytes
2025-10-31T16:27:28.847Z:INFO:taskCANopen.c:1821:Added object 0x205f, 8 bytes
2025-10-31T16:27:28.875Z:INFO:taskCANopen.c:1821:Added object 0x2061, 2 bytes
2025-10-31T16:27:28.902Z:INFO:taskCANopen.c:1821:Added object 0x2062, 4 bytes
2025-10-31T16:27:28.929Z:INFO:taskCANopen.c:1821:Added object 0x2063, 21 bytes
2025-10-31T16:27:28.957Z:INFO:taskCANopen.c:1821:Added object 0x2064, 1 bytes
2025-10-31T16:27:28.992Z:INFO:taskCANopen.c:1821:Added object 0x2065, 4 bytes
2025-10-31T16:27:29.019Z:INFO:taskCANopen.c:1821:Added object 0x2067, 4 bytes
2025-10-31T16:27:29.050Z:INFO:taskCANopen.c:1821:Added object 0x2068, 4 bytes
2025-10-31T16:27:29.078Z:INFO:taskCANopen.c:1821:Added object 0x2069, 7 bytes
2025-10-31T16:27:29.109Z:INFO:taskCANopen.c:1821:Added object 0x206a, 4 bytes
2025-10-31T16:27:29.160Z:INFO:taskCANopen.c:1821:Added object 0x206b, 6 bytes
2025-10-31T16:27:29.195Z:USER:bspEthernet.c:342:Mode: 100Mb/s full duplex
2025-10-31T16:27:29.203Z:INFO:taskTCPIP.c:958:Network Cable is now connected
2025-10-31T16:27:29.226Z:INFO:taskCANopen.c:1821:Added object 0x206c, 12 bytes
2025-10-31T16:27:29.257Z:INFO:taskCANopen.c:1821:Added object 0x206e, 2 bytes
2025-10-31T16:27:29.289Z:INFO:taskCANopen.c:1821:Added object 0x206f, 1 bytes
2025-10-31T16:27:29.320Z:INFO:taskCANopen.c:1821:Added object 0x2070, 1 bytes
2025-10-31T16:27:29.363Z:INFO:taskCANopen.c:1821:Added object 0x2072, 18 bytes
2025-10-31T16:27:29.406Z:INFO:taskCANopen.c:1821:Added object 0x2073, 18 bytes
2025-10-31T16:27:29.449Z:INFO:taskCANopen.c:1821:Added object 0x2074, 18 bytes
2025-10-31T16:27:29.496Z:INFO:taskCANopen.c:1821:Added object 0x2075, 18 bytes
2025-10-31T16:27:29.531Z:INFO:taskCANopen.c:1821:Added object 0x2076, 51 bytes
2025-10-31T16:27:29.574Z:INFO:taskCANopen.c:1821:Added object 0x2079, 18 bytes
2025-10-31T16:27:29.621Z:INFO:taskCANopen.c:1821:Added object 0x207a, 18 bytes
2025-10-31T16:27:29.671Z:INFO:taskCANopen.c:1821:Added object 0x207b, 18 bytes
2025-10-31T16:27:29.718Z:INFO:taskCANopen.c:1821:Added object 0x207c, 18 bytes
2025-10-31T16:27:29.765Z:INFO:taskCANopen.c:1821:Added object 0x207d, 18 bytes
2025-10-31T16:27:29.812Z:INFO:taskCANopen.c:1821:Added object 0x207e, 18 bytes
2025-10-31T16:27:29.863Z:INFO:taskCANopen.c:1821:Added object 0x207f, 18 bytes
2025-10-31T16:27:29.910Z:INFO:taskCANopen.c:1821:Added object 0x2080, 18 bytes
2025-10-31T16:27:29.953Z:INFO:taskCANopen.c:1821:Added object 0x2085, 4 bytes
2025-10-31T16:27:29.992Z:INFO:taskCANopen.c:1821:Added object 0x2087, 4 bytes
2025-10-31T16:27:30.007Z:INFO:taskTCPIP.c:1617: IP address assigned by DHCP
2025-10-31T16:27:30.015Z:INFO:taskTCPIP.c:1645:Network interface is up
2025-10-31T16:27:30.023Z:INFO:taskTCPIP.c:1654: IP : 192.168.178.184
2025-10-31T16:27:30.031Z:INFO:taskTCPIP.c:1655: Netmask : 255.255.255.0
2025-10-31T16:27:30.039Z:INFO:taskTCPIP.c:1656: Gateway : 192.168.178.1
2025-10-31T16:27:30.046Z:INFO:taskTCPIP.c:1657: DNS1 : 192.168.178.1
2025-10-31T16:27:30.054Z:INFO:taskTCPIP.c:1658: DNS2 : 208.67.220.220
2025-10-31T16:27:30.062Z:INFO:taskCANopen.c:1821:Added object 0x2088, 1 bytes
2025-10-31T16:27:30.074Z:INFO:taskTCPIP.c:512:Starting mDNS on interface al
2025-10-31T16:27:30.082Z:INFO:taskTCPIP.c:512:Starting Webserver on interface al
2025-10-31T16:27:30.089Z:INFO:taskTCPIP.c:512:Starting Modbus on interface al
2025-10-31T16:27:30.097Z:INFO:taskTCPIP.c:512:Starting P1 on interface al
2025-10-31T16:27:30.105Z:INFO:taskTCPIP.c:512:Starting SCN on interface al
2025-10-31T16:27:30.113Z:INFO:taskTCPIP.c:413:default network set to 'al'
2025-10-31T16:27:30.125Z:INFO:taskCANopen.c:1821:Added object 0x2089, 1 bytes
2025-10-31T16:27:30.132Z:WARNING:taskModbus.c:886:Socket_1 Meter(1): cannot initialise type ABB, trying auto-detect
2025-10-31T16:27:30.144Z:INFO:taskWebServer.c:238:WebServer state WAIT_FOR_NETWORK -> SETUP
2025-10-31T16:27:30.156Z:USER:taskMaster.c:1329:Node #1, version 7.3.0-4377
2025-10-31T16:27:30.164Z:INFO:taskCANopen.c:1821:Added object 0x208a, 4 bytes
2025-10-31T16:27:30.195Z:INFO:taskModbus.c:924:Socket_1 Meter(1): Meter type ABB not detected
2025-10-31T16:27:30.203Z:USER:taskWebServer.c:360:WebServer started on port 443
2025-10-31T16:27:30.214Z:INFO:taskCANopen.c:1821:Added object 0x208c, 4 bytes
2025-10-31T16:27:30.222Z:INFO:taskWebServer.c:238:WebServer state SETUP -> AVAILABLE
2025-10-31T16:27:30.257Z:INFO:taskCANopen.c:1821:Added object 0x208d, 4 bytes
2025-10-31T16:27:30.300Z:INFO:taskCANopen.c:1821:Added object 0x208e, 4 bytes
2025-10-31T16:27:30.343Z:INFO:taskCANopen.c:1821:Added object 0x208f, 2 bytes
2025-10-31T16:27:30.386Z:INFO:taskCANopen.c:1821:Added object 0x2094, 1 bytes
2025-10-31T16:27:30.433Z:INFO:taskCANopen.c:1821:Added object 0x2095, 1 bytes
2025-10-31T16:27:30.476Z:INFO:taskCANopen.c:1821:Added object 0x2096, 2 bytes
2025-10-31T16:27:30.523Z:INFO:taskCANopen.c:1821:Added object 0x2097, 4 bytes
2025-10-31T16:27:30.570Z:INFO:taskCANopen.c:1821:Added object 0x2098, 36 bytes
2025-10-31T16:27:30.617Z:INFO:taskCANopen.c:1821:Added object 0x2099, 36 bytes
2025-10-31T16:27:30.664Z:INFO:taskCANopen.c:1821:Added object 0x209a, 4 bytes
2025-10-31T16:27:30.710Z:INFO:taskCANopen.c:1821:Added object 0x209b, 1 bytes
2025-10-31T16:27:30.757Z:INFO:taskCANopen.c:1821:Added object 0x209c, 1 bytes
2025-10-31T16:27:30.808Z:INFO:taskCANopen.c:1821:Added object 0x209d, 1 bytes
2025-10-31T16:27:30.980Z:INFO:taskCANopen.c:1821:Added object 0x20f0, 1142 bytes
2025-10-31T16:27:31.156Z:INFO:taskCANopen.c:1821:Added object 0x20f1, 1142 bytes
2025-10-31T16:27:31.328Z:INFO:taskCANopen.c:1821:Added object 0x20f2, 1142 bytes
2025-10-31T16:27:31.507Z:INFO:taskCANopen.c:1821:Added object 0x20f3, 1142 bytes
2025-10-31T16:27:31.558Z:INFO:taskCANopen.c:1821:Added object 0x20f4, 1 bytes
2025-10-31T16:27:31.609Z:INFO:taskCANopen.c:1821:Added object 0x20f5, 1 bytes
2025-10-31T16:27:31.664Z:INFO:taskCANopen.c:1821:Added object 0x20f6, 1 bytes
2025-10-31T16:27:31.714Z:INFO:taskCANopen.c:1821:Added object 0x20f7, 1 bytes
2025-10-31T16:27:31.769Z:INFO:taskCANopen.c:1821:Added object 0x2106, 1 bytes
2025-10-31T16:27:31.824Z:INFO:taskCANopen.c:1821:Added object 0x2107, 1 bytes
2025-10-31T16:27:31.878Z:INFO:taskCANopen.c:1821:Added object 0x2108, 1 bytes
2025-10-31T16:27:31.933Z:INFO:taskCANopen.c:1821:Added object 0x2109, 1 bytes
2025-10-31T16:27:31.988Z:INFO:taskCANopen.c:1821:Added object 0x2111, 2 bytes
2025-10-31T16:27:32.042Z:INFO:taskCANopen.c:1821:Added object 0x2113, 1 bytes
2025-10-31T16:27:32.101Z:INFO:taskCANopen.c:1821:Added object 0x2114, 1 bytes
2025-10-31T16:27:32.160Z:INFO:taskCANopen.c:1821:Added object 0x2115, 64 bytes
2025-10-31T16:27:32.222Z:INFO:taskCANopen.c:1821:Added object 0x2116, 32 bytes
2025-10-31T16:27:32.277Z:INFO:taskCANopen.c:1821:Added object 0x2117, 1 bytes
2025-10-31T16:27:32.339Z:INFO:taskCANopen.c:1821:Added object 0x2124, 1 bytes
2025-10-31T16:27:32.398Z:INFO:taskCANopen.c:1821:Added object 0x2125, 1 bytes
2025-10-31T16:27:32.457Z:INFO:taskCANopen.c:1821:Added object 0x2126, 1 bytes
2025-10-31T16:27:32.515Z:INFO:taskCANopen.c:1821:Added object 0x2127, 1 bytes
2025-10-31T16:27:32.570Z:INFO:comConnect.c:295:Connectivity state: INITIALISING
2025-10-31T16:27:32.582Z:INFO:taskCANopen.c:1821:Added object 0x2129, 4 bytes
2025-10-31T16:27:32.589Z:USER:taskMaster.c:1359:NFC version: ICU NFC 243B (v3) v3.1-531
2025-10-31T16:27:32.597Z:INFO:taskNFCreader.c:115:Port #0 version response: "ICU NFC 243B (v3) v3.1-531"
2025-10-31T16:27:32.609Z:INFO:comConnect.c:295:Connectivity state: STANDALONE
2025-10-31T16:27:32.644Z:INFO:taskCANopen.c:1821:Added object 0x2130, 4 bytes
2025-10-31T16:27:32.707Z:INFO:taskCANopen.c:1821:Added object 0x2131, 1 bytes
2025-10-31T16:27:32.761Z:INFO:taskNFCreader.c:131:Port #0 ICU NFC reader BL3 v3.1, 1 LEDs
2025-10-31T16:27:32.769Z:INFO:taskCANopen.c:1821:Added object 0x2132, 2 bytes
2025-10-31T16:27:32.777Z:INFO:taskNFCreader.c:132:Port #0 reader model: Giro-e
2025-10-31T16:27:32.832Z:INFO:taskCANopen.c:1821:Added object 0x2133, 2 bytes
2025-10-31T16:27:32.843Z:SECURITY:featureKeys.c:278:LicenseKeyUpdated
2025-10-31T16:27:32.898Z:INFO:taskCANopen.c:1821:Added object 0x2134, 2 bytes
2025-10-31T16:27:32.960Z:INFO:taskCANopen.c:1821:Added object 0x2135, 2 bytes
2025-10-31T16:27:33.023Z:INFO:taskCANopen.c:1821:Added object 0x2136, 2 bytes
2025-10-31T16:27:33.089Z:INFO:taskCANopen.c:1821:Added object 0x2137, 1 bytes
2025-10-31T16:27:33.156Z:INFO:taskCANopen.c:1821:Added object 0x2138, 1 bytes
2025-10-31T16:27:33.222Z:INFO:taskCANopen.c:1821:Added object 0x2139, 2 bytes
2025-10-31T16:27:33.285Z:INFO:taskCANopen.c:1821:Added object 0x213b, 1 bytes
2025-10-31T16:27:33.355Z:INFO:taskCANopen.c:1821:Added object 0x213c, 1 bytes
2025-10-31T16:27:33.421Z:INFO:taskCANopen.c:1821:Added object 0x213d, 1 bytes
2025-10-31T16:27:33.484Z:ERROR:taskNFCreader.c:562:NFC tag delay too large (2000 ms), corrected to 1000 ms
2025-10-31T16:27:33.496Z:INFO:taskCANopen.c:1821:Added object 0x213e, 1 bytes
2025-10-31T16:27:33.562Z:INFO:taskCANopen.c:1821:Added object 0x213f, 2 bytes
2025-10-31T16:27:33.632Z:INFO:taskCANopen.c:1821:Added object 0x2140, 2 bytes
2025-10-31T16:27:33.703Z:INFO:taskCANopen.c:1821:Added object 0x2142, 2 bytes
2025-10-31T16:27:33.773Z:INFO:taskCANopen.c:1821:Added object 0x2143, 2 bytes
2025-10-31T16:27:33.843Z:INFO:taskCANopen.c:1821:Added object 0x2144, 1 bytes
2025-10-31T16:27:33.914Z:INFO:taskCANopen.c:1821:Added object 0x2146, 2 bytes
2025-10-31T16:27:33.984Z:INFO:taskCANopen.c:1821:Added object 0x2148, 2 bytes
2025-10-31T16:27:34.058Z:INFO:taskCANopen.c:1821:Added object 0x2149, 2 bytes
2025-10-31T16:27:34.132Z:INFO:taskCANopen.c:1821:Added object 0x2150, 2 bytes
2025-10-31T16:27:34.203Z:INFO:taskCANopen.c:1821:Added object 0x2153, 2 bytes
2025-10-31T16:27:34.281Z:INFO:taskCANopen.c:1821:Added object 0x2155, 1 bytes
2025-10-31T16:27:34.355Z:INFO:taskCANopen.c:1821:Added object 0x2156, 1 bytes
2025-10-31T16:27:34.429Z:INFO:taskCANopen.c:1821:Added object 0x2158, 2 bytes
2025-10-31T16:27:34.507Z:INFO:taskCANopen.c:1821:Added object 0x2159, 1 bytes
2025-10-31T16:27:34.582Z:INFO:taskCANopen.c:1821:Added object 0x215c, 1 bytes
2025-10-31T16:27:34.656Z:INFO:taskCANopen.c:1821:Added object 0x215d, 1 bytes
2025-10-31T16:27:34.734Z:INFO:taskCANopen.c:1821:Added object 0x215e, 1 bytes
2025-10-31T16:27:34.812Z:INFO:taskCANopen.c:1821:Added object 0x2162, 2 bytes
2025-10-31T16:27:34.820Z:INFO:modem.c:1124:Modem state InitHw->InitModem
2025-10-31T16:27:34.828Z:INFO:modem.c:1296:Reset delay 2s
2025-10-31T16:27:34.890Z:INFO:taskCANopen.c:1821:Added object 0x2164, 1 bytes
2025-10-31T16:27:34.968Z:INFO:taskCANopen.c:1821:Added object 0x2168, 2 bytes
2025-10-31T16:27:35.046Z:INFO:taskCANopen.c:1821:Added object 0x2169, 2 bytes
2025-10-31T16:27:35.125Z:INFO:taskCANopen.c:1821:Added object 0x216a, 1 bytes
2025-10-31T16:27:35.207Z:INFO:taskCANopen.c:1821:Added object 0x216b, 1 bytes
2025-10-31T16:27:35.285Z:INFO:taskCANopen.c:1821:Added object 0x216c, 1 bytes
2025-10-31T16:27:35.367Z:INFO:taskCANopen.c:1821:Added object 0x216d, 1 bytes
2025-10-31T16:27:35.449Z:INFO:taskCANopen.c:1821:Added object 0x216f, 1 bytes
2025-10-31T16:27:35.531Z:INFO:taskCANopen.c:1821:Added object 0x2171, 1 bytes
2025-10-31T16:27:35.597Z:INFO:taskMaster.c:1137:Socket #1 has a Modbus meter
2025-10-31T16:27:35.609Z:INFO:updatefirmware.c:52:BL FWU_STATUS_INACTIVE -> int IDLE
2025-10-31T16:27:35.617Z:USER:taskMaster.c:1164:1 NFC readers found
2025-10-31T16:27:35.625Z:INFO:smartMeter.c:80:Set phases: (L1, L2, L3)->(L1, L2, L3)
2025-10-31T16:27:35.632Z:INFO:taskMaster.c:4957:Socket #1: state main : BOOTING
2025-10-31T16:27:35.640Z:WARNING:taskMaster.c:7470:Meter #1: No metervalue available, delaying transaction.
2025-10-31T16:27:35.652Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-10-31T16:27:35.660Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-10-31T16:27:35.671Z:INFO:taskMaster.c:4979:Socket #1: state led : BOOTING
2025-10-31T16:27:35.679Z:INFO:taskCANopen.c:1821:Added object 0x2172, 1 bytes
2025-10-31T16:27:35.796Z:INFO:taskCANopen.c:1821:Added object 0x2173, 4 bytes
2025-10-31T16:27:35.804Z:INFO:taskMaster.c:6376:Socket #1: no schedule
2025-10-31T16:27:35.812Z:USER:taskMaster.c:6402:Socket #1: external current limit 16.0 A
2025-10-31T16:27:35.820Z:INFO:station.c:97:station external max - new value: 99.9A
2025-10-31T16:27:35.832Z:INFO:comFaults.c:482:Reset fault status
2025-10-31T16:27:35.839Z:ERROR:comFaults.c:365:Socket #1: Unable to communicate with power meter [105]
2025-10-31T16:27:35.882Z:INFO:taskCANopen.c:1821:Added object 0x2174, 4 bytes
2025-10-31T16:27:35.976Z:INFO:taskCANopen.c:1821:Added object 0x2177, 224 bytes
2025-10-31T16:27:36.070Z:INFO:taskCANopen.c:1821:Added object 0x2178, 224 bytes
2025-10-31T16:27:36.156Z:INFO:taskCANopen.c:1821:Added object 0x2179, 1 bytes
2025-10-31T16:27:36.289Z:INFO:taskCANopen.c:1821:Added object 0x2180, 28 bytes
2025-10-31T16:27:36.375Z:INFO:taskCANopen.c:1821:Added object 0x2182, 2 bytes
2025-10-31T16:27:36.460Z:INFO:taskCANopen.c:1821:Added object 0x2183, 1 bytes
2025-10-31T16:27:36.550Z:INFO:taskCANopen.c:1821:Added object 0x2184, 2 bytes
2025-10-31T16:27:36.640Z:INFO:taskCANopen.c:1821:Added object 0x2185, 1 bytes
2025-10-31T16:27:36.726Z:INFO:taskCANopen.c:1821:Added object 0x2187, 8 bytes
2025-10-31T16:27:36.816Z:INFO:taskCANopen.c:1821:Added object 0x2188, 1 bytes
2025-10-31T16:27:36.906Z:INFO:taskCANopen.c:1821:Added object 0x2189, 1 bytes
2025-10-31T16:27:36.996Z:INFO:taskCANopen.c:1821:Added object 0x218a, 1 bytes
2025-10-31T16:27:37.085Z:INFO:taskCANopen.c:1821:Added object 0x218b, 1 bytes
2025-10-31T16:27:37.175Z:INFO:taskCANopen.c:1821:Added object 0x218e, 4 bytes
2025-10-31T16:27:37.265Z:INFO:taskCANopen.c:1821:Added object 0x2190, 1 bytes
2025-10-31T16:27:37.375Z:INFO:taskCANopen.c:1821:Added object 0x2191, 20 bytes
2025-10-31T16:27:37.468Z:INFO:taskCANopen.c:1821:Added object 0x2192, 1 bytes
2025-10-31T16:27:37.562Z:INFO:taskCANopen.c:1821:Added object 0x21a1, 30 bytes
2025-10-31T16:27:37.656Z:INFO:taskCANopen.c:1821:Added object 0x21b0, 1 bytes
2025-10-31T16:27:37.750Z:INFO:taskCANopen.c:1821:Added object 0x21b1, 1 bytes
2025-10-31T16:27:37.843Z:INFO:taskCANopen.c:1821:Added object 0x21b2, 1 bytes
2025-10-31T16:27:37.941Z:INFO:taskCANopen.c:1821:Added object 0x21b3, 8 bytes
2025-10-31T16:27:38.035Z:INFO:taskCANopen.c:1821:Added object 0x21b4, 1 bytes
2025-10-31T16:27:38.132Z:INFO:taskCANopen.c:1821:Added object 0x21b5, 1 bytes
2025-10-31T16:27:38.230Z:INFO:taskCANopen.c:1821:Added object 0x21b6, 8 bytes
2025-10-31T16:27:38.328Z:INFO:taskCANopen.c:1821:Added object 0x21b7, 1 bytes
2025-10-31T16:27:38.421Z:INFO:taskCANopen.c:1821:Added object 0x21b9, 2 bytes
2025-10-31T16:27:38.519Z:INFO:taskCANopen.c:1821:Added object 0x2200, 1 bytes
2025-10-31T16:27:38.621Z:INFO:taskCANopen.c:1821:Added object 0x2202, 4 bytes
2025-10-31T16:27:38.718Z:INFO:taskCANopen.c:1821:Added object 0x2203, 4 bytes
2025-10-31T16:27:38.820Z:INFO:taskCANopen.c:1821:Added object 0x2204, 2 bytes
2025-10-31T16:27:38.917Z:INFO:taskCANopen.c:1821:Added object 0x2205, 2 bytes
2025-10-31T16:27:39.015Z:USER:modem.c:3611:Modem type: Quectel BG95-M3
2025-10-31T16:27:39.023Z:INFO:taskCANopen.c:1821:Added object 0x2206, 1 bytes
2025-10-31T16:27:39.031Z:INFO:modem.c:3090:Check if modem responds
2025-10-31T16:27:39.070Z:INFO:modem.c:2977:Set flow control (on)
2025-10-31T16:27:39.125Z:INFO:taskCANopen.c:1821:Added object 0x2210, 2 bytes
2025-10-31T16:27:39.226Z:INFO:taskCANopen.c:1821:Added object 0x2211, 2 bytes
2025-10-31T16:27:39.242Z:INFO:modem.c:3130:Set type of logging
2025-10-31T16:27:39.332Z:INFO:taskCANopen.c:1821:Added object 0x2212, 2 bytes
2025-10-31T16:27:39.433Z:INFO:taskCANopen.c:1821:Added object 0x2213, 2 bytes
2025-10-31T16:27:39.535Z:INFO:taskCANopen.c:1821:Added object 0x2214, 2 bytes
2025-10-31T16:27:39.640Z:INFO:taskCANopen.c:1821:Added object 0x2215, 2 bytes
2025-10-31T16:27:39.746Z:INFO:taskCANopen.c:1821:Added object 0x2216, 2 bytes
2025-10-31T16:27:39.847Z:INFO:taskCANopen.c:1821:Added object 0x2218, 1 bytes
2025-10-31T16:27:39.953Z:INFO:taskCANopen.c:1821:Added object 0x2219, 2 bytes
2025-10-31T16:27:40.058Z:INFO:taskCANopen.c:1821:Added object 0x2220, 8 bytes
2025-10-31T16:27:40.179Z:INFO:taskCANopen.c:1821:Added object 0x2249, 9 bytes
2025-10-31T16:27:40.289Z:INFO:taskCANopen.c:1821:Added object 0x2250, 1 bytes
2025-10-31T16:27:40.394Z:INFO:taskCANopen.c:1821:Added object 0x2300, 10 bytes
2025-10-31T16:27:40.503Z:INFO:taskCANopen.c:1821:Added object 0x2301, 10 bytes
2025-10-31T16:27:40.613Z:INFO:taskCANopen.c:1821:Added object 0x2302, 10 bytes
2025-10-31T16:27:40.722Z:INFO:taskCANopen.c:1821:Added object 0x2303, 10 bytes
2025-10-31T16:27:40.835Z:INFO:taskCANopen.c:1821:Added object 0x2304, 10 bytes
2025-10-31T16:27:40.945Z:INFO:taskCANopen.c:1821:Added object 0x2305, 10 bytes
2025-10-31T16:27:41.074Z:INFO:taskCANopen.c:1821:Added object 0x2306, 10 bytes
2025-10-31T16:27:41.183Z:INFO:taskCANopen.c:1821:Added object 0x2307, 10 bytes
2025-10-31T16:27:41.296Z:INFO:taskCANopen.c:1821:Added object 0x2308, 10 bytes
2025-10-31T16:27:41.410Z:INFO:taskCANopen.c:1821:Added object 0x2309, 10 bytes
2025-10-31T16:27:41.519Z:INFO:taskCANopen.c:1821:Added object 0x2310, 10 bytes
2025-10-31T16:27:41.636Z:INFO:taskCANopen.c:1821:Added object 0x2311, 10 bytes
2025-10-31T16:27:41.750Z:INFO:taskCANopen.c:1821:Added object 0x2312, 10 bytes
2025-10-31T16:27:41.863Z:INFO:taskCANopen.c:1821:Added object 0x2313, 10 bytes
2025-10-31T16:27:41.984Z:INFO:taskCANopen.c:1821:Added object 0x2314, 10 bytes
2025-10-31T16:27:42.097Z:INFO:taskCANopen.c:1821:Added object 0x2315, 10 bytes
2025-10-31T16:27:42.214Z:INFO:taskCANopen.c:1821:Added object 0x2316, 10 bytes
2025-10-31T16:27:42.335Z:INFO:taskCANopen.c:1821:Added object 0x2317, 10 bytes
2025-10-31T16:27:42.453Z:INFO:taskCANopen.c:1821:Added object 0x2318, 10 bytes
2025-10-31T16:27:42.570Z:INFO:taskCANopen.c:1821:Added object 0x2319, 10 bytes
2025-10-31T16:27:42.691Z:INFO:taskCANopen.c:1821:Added object 0x2320, 10 bytes
2025-10-31T16:27:42.808Z:INFO:taskCANopen.c:1821:Added object 0x2321, 10 bytes
2025-10-31T16:27:42.929Z:INFO:taskCANopen.c:1821:Added object 0x2322, 10 bytes
2025-10-31T16:27:43.050Z:INFO:taskCANopen.c:1821:Added object 0x2323, 10 bytes
2025-10-31T16:27:43.167Z:INFO:taskCANopen.c:1821:Added object 0x2324, 10 bytes
2025-10-31T16:27:43.289Z:INFO:taskCANopen.c:1821:Added object 0x2325, 10 bytes
2025-10-31T16:27:43.410Z:INFO:taskCANopen.c:1821:Added object 0x2326, 10 bytes
2025-10-31T16:27:43.531Z:INFO:taskCANopen.c:1821:Added object 0x2327, 10 bytes
2025-10-31T16:27:43.652Z:INFO:taskCANopen.c:1821:Added object 0x2328, 10 bytes
2025-10-31T16:27:43.777Z:INFO:taskCANopen.c:1821:Added object 0x2329, 10 bytes
2025-10-31T16:27:43.902Z:INFO:taskCANopen.c:1821:Added object 0x2330, 10 bytes
2025-10-31T16:27:44.027Z:INFO:taskCANopen.c:1821:Added object 0x2331, 10 bytes
2025-10-31T16:27:44.152Z:INFO:taskCANopen.c:1821:Added object 0x2332, 10 bytes
2025-10-31T16:27:44.277Z:INFO:taskCANopen.c:1821:Added object 0x2333, 10 bytes
2025-10-31T16:27:44.402Z:INFO:taskCANopen.c:1821:Added object 0x2334, 10 bytes
2025-10-31T16:27:44.527Z:INFO:taskCANopen.c:1821:Added object 0x2335, 10 bytes
2025-10-31T16:27:44.652Z:INFO:taskCANopen.c:1821:Added object 0x2336, 10 bytes
2025-10-31T16:27:44.781Z:INFO:taskCANopen.c:1821:Added object 0x2337, 10 bytes
2025-10-31T16:27:44.906Z:INFO:taskCANopen.c:1821:Added object 0x2338, 10 bytes
2025-10-31T16:27:45.035Z:INFO:taskCANopen.c:1821:Added object 0x2350, 10 bytes
2025-10-31T16:27:45.175Z:INFO:taskCANopen.c:1821:Added object 0x2400, 23 bytes
2025-10-31T16:27:45.304Z:INFO:taskCANopen.c:1821:Added object 0x2401, 37 bytes
2025-10-31T16:27:45.464Z:INFO:taskCANopen.c:1821:Added object 0x2522, 24 bytes
2025-10-31T16:27:45.625Z:INFO:taskCANopen.c:1821:Added object 0x2523, 24 bytes
2025-10-31T16:27:45.777Z:INFO:taskCANopen.c:1821:Added object 0x2530, 6 bytes
2025-10-31T16:27:45.890Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:27:45.937Z:INFO:taskCANopen.c:1821:Added object 0x2560, 50 bytes
2025-10-31T16:27:46.078Z:INFO:taskCANopen.c:1821:Added object 0x2561, 100 bytes
2025-10-31T16:27:46.210Z:INFO:taskCANopen.c:1821:Added object 0x2562, 50 bytes
2025-10-31T16:27:46.351Z:INFO:taskCANopen.c:1821:Added object 0x2563, 50 bytes
2025-10-31T16:27:46.421Z:SECURITY:httpd_login.c:155:WebClient RadomskiR connected (account: admin)
2025-10-31T16:27:46.503Z:INFO:taskCANopen.c:1821:Added object 0x2564, 11 bytes
2025-10-31T16:27:46.652Z:INFO:taskCANopen.c:1821:Added object 0x2565, 7 bytes
2025-10-31T16:27:46.789Z:INFO:taskCANopen.c:1821:Added object 0x2570, 50 bytes
2025-10-31T16:27:46.921Z:INFO:taskCANopen.c:1821:Added object 0x2571, 100 bytes
2025-10-31T16:27:47.066Z:INFO:taskCANopen.c:1821:Added object 0x2572, 50 bytes
2025-10-31T16:27:47.199Z:INFO:taskCANopen.c:1821:Added object 0x2573, 50 bytes
2025-10-31T16:27:47.355Z:INFO:taskCANopen.c:1821:Added object 0x2574, 11 bytes
2025-10-31T16:27:47.507Z:INFO:taskCANopen.c:1821:Added object 0x2575, 7 bytes
2025-10-31T16:27:47.644Z:INFO:taskCANopen.c:1821:Added object 0x2703, 1 bytes
2025-10-31T16:27:47.695Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x50)
2025-10-31T16:27:47.707Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-31T16:27:47.742Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-31T16:27:47.781Z:INFO:taskCANopen.c:1821:Added object 0x2710, 1 bytes
2025-10-31T16:27:47.921Z:INFO:taskCANopen.c:1821:Added object 0x2722, 51 bytes
2025-10-31T16:27:48.062Z:INFO:taskCANopen.c:1821:Added object 0x2723, 1 bytes
2025-10-31T16:27:48.207Z:INFO:taskCANopen.c:1821:Added object 0x2909, 4 bytes
2025-10-31T16:27:48.347Z:INFO:taskCANopen.c:1821:Added object 0x3125, 1 bytes
2025-10-31T16:27:48.488Z:INFO:taskCANopen.c:1821:Added object 0x3129, 4 bytes
2025-10-31T16:27:48.628Z:INFO:taskCANopen.c:1821:Added object 0x3160, 4 bytes
2025-10-31T16:27:48.769Z:INFO:taskCANopen.c:1821:Added object 0x3173, 4 bytes
2025-10-31T16:27:48.917Z:INFO:taskCANopen.c:1821:Added object 0x3218, 1 bytes
2025-10-31T16:27:49.058Z:INFO:taskCANopen.c:1821:Added object 0x3220, 8 bytes
2025-10-31T16:27:49.203Z:INFO:taskCANopen.c:1821:Added object 0x3258, 4 bytes
2025-10-31T16:27:49.343Z:INFO:taskCANopen.c:1821:Added object 0x3261, 2 bytes
2025-10-31T16:27:49.523Z:INFO:taskCANopen.c:1821:Added object 0x3262, 55 bytes
2025-10-31T16:27:49.714Z:INFO:taskCANopen.c:1821:Added object 0x3263, 519 bytes
2025-10-31T16:27:49.859Z:INFO:taskCANopen.c:1821:Added object 0x3264, 4 bytes
2025-10-31T16:27:50.003Z:INFO:taskCANopen.c:1821:Added object 0x3265, 4 bytes
2025-10-31T16:27:50.148Z:INFO:taskCANopen.c:1821:Added object 0x3266, 1 bytes
2025-10-31T16:27:50.296Z:INFO:taskCANopen.c:1821:Added object 0x3267, 1 bytes
2025-10-31T16:27:50.445Z:INFO:taskCANopen.c:1821:Added object 0x3268, 1 bytes
2025-10-31T16:27:50.593Z:INFO:taskCANopen.c:1821:Added object 0x3269, 1 bytes
2025-10-31T16:27:50.742Z:INFO:taskCANopen.c:1821:Added object 0x3270, 4 bytes
2025-10-31T16:27:50.921Z:INFO:taskCANopen.c:1821:Added object 0x3271, 14 bytes
2025-10-31T16:27:51.078Z:INFO:taskCANopen.c:1821:Added object 0x3272, 1 bytes
2025-10-31T16:27:51.109Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:27:51.230Z:INFO:taskCANopen.c:1821:Added object 0x3273, 3 bytes
2025-10-31T16:27:51.378Z:INFO:taskCANopen.c:1821:Added object 0x3274, 1 bytes
2025-10-31T16:27:51.531Z:INFO:taskCANopen.c:1821:Added object 0x3275, 4 bytes
2025-10-31T16:27:51.726Z:INFO:taskCANopen.c:1821:Added object 0x3276, 132 bytes
2025-10-31T16:27:51.902Z:SECURITY:httpd_login.c:155:WebClient RadomskiR connected (account: admin)
2025-10-31T16:27:51.917Z:INFO:taskCANopen.c:1821:Added object 0x3277, 14 bytes
2025-10-31T16:27:52.019Z:WARNING:web_functionali:139:Could not find prop dwId 2100.00
2025-10-31T16:27:52.031Z:WARNING:web_functionali:139:Could not find prop dwId 2101.00
2025-10-31T16:27:52.039Z:WARNING:web_functionali:139:Could not find prop dwId 2102.00
2025-10-31T16:27:52.050Z:WARNING:web_functionali:139:Could not find prop dwId 2103.00
2025-10-31T16:27:52.058Z:WARNING:web_functionali:139:Could not find prop dwId 2078.01
2025-10-31T16:27:52.070Z:WARNING:web_functionali:139:Could not find prop dwId 2078.02
2025-10-31T16:27:52.078Z:SECURITY:web_functionalit:58:Changed '21A1_00' from '0480.CB00.A900.B200.FA77.2311' => '3180.1401.C001.5E01.5
2025-10-31T16:27:52.078Z:SECURITY:web_functionalit:58:975.365B'
2025-10-31T16:27:52.097Z:INFO:taskCANopen.c:1821:Added object 0x3280, 9 bytes
2025-10-31T16:27:52.132Z:INFO:featureKeys.c:78:Unlocked Features: SCN,RFID-reader,4G (80010101)
2025-10-31T16:27:52.140Z:SECURITY:web_functionalit:58:Changed '2053_00' from 'AL1000' => 'VAN_01971'
2025-10-31T16:27:52.152Z:WARNING:scn_communicatio:75:SCN: Not enough sockets for an SCN!
2025-10-31T16:27:52.160Z:SECURITY:web_functionalit:58:Changed '2050_00' from 'EVe-dual' => 'NG910-60583'
2025-10-31T16:27:52.171Z:SECURITY:web_functionalit:65:Changed '204F_00' from 0 => 49
2025-10-31T16:27:52.179Z:SECURITY:web_functionalit:58:Changed '2076_00' from 'Stand-alone, all cards' => 'Last Mile Solutions (KPN)'
2025-10-31T16:27:52.191Z:SECURITY:web_functionalit:58:Changed '2079_01' from '8.8.8.8' => ''
2025-10-31T16:27:52.203Z:SECURITY:web_functionalit:58:Changed '2080_01' from '208.67.222.222' => ''
2025-10-31T16:27:52.210Z:SECURITY:web_functionalit:58:Changed '207E_01' from '192.168.178.1' => ''
2025-10-31T16:27:52.222Z:SECURITY:web_functionalit:58:Changed '207F_01' from '208.67.220.220' => ''
2025-10-31T16:27:52.285Z:INFO:taskCANopen.c:1821:Added object 0x3281, 10 bytes
2025-10-31T16:27:52.437Z:INFO:taskCANopen.c:1821:Added object 0x3282, 10 bytes
2025-10-31T16:27:52.500Z:WARNING:web_functionali:139:Could not find prop dwId 2071.01
2025-10-31T16:27:52.511Z:WARNING:web_functionali:139:Could not find prop dwId 2071.02
2025-10-31T16:27:52.523Z:WARNING:web_functionali:139:Could not find prop dwId 2081.00
2025-10-31T16:27:52.531Z:WARNING:web_functionali:139:Could not find prop dwId 2082.00
2025-10-31T16:27:52.542Z:WARNING:web_functionali:139:Could not find prop dwId 2093.00
2025-10-31T16:27:52.550Z:SECURITY:web_functionalit:65:Changed '2136_00' from 2 => 10
2025-10-31T16:27:52.562Z:SECURITY:web_functionalit:63:Changed '2061_01' from 3 => 1
2025-10-31T16:27:52.570Z:SECURITY:web_functionalit:63:Changed '2061_02' from 75 => 100
2025-10-31T16:27:52.578Z:SECURITY:web_functionalit:65:Changed '2096_00' from 10 => 0
2025-10-31T16:27:52.589Z:SECURITY:web_functionalit:63:Changed '20f0_01' from 0 => 3
2025-10-31T16:27:52.597Z:SECURITY:web_functionalit:58:Changed '20F0_03' from '' => 'ws://ws.evc-net.com/'
2025-10-31T16:27:52.609Z:INFO:taskCANopen.c:1821:Added object 0x3283, 10 bytes
2025-10-31T16:27:52.746Z:SECURITY:web_functionalit:63:Changed '20f0_06' from 0 => 1
2025-10-31T16:27:52.757Z:SECURITY:web_functionalit:63:Changed '20f0_0e' from 0 => 1
2025-10-31T16:27:52.765Z:SECURITY:web_functionalit:63:Changed '20f1_01' from 2 => 3
2025-10-31T16:27:52.773Z:SECURITY:web_functionalit:58:Changed '20F1_03' from 'ws://icuconnect.nl:9090' => 'ws://ws-private.evc-net.com
2025-10-31T16:27:52.773Z:SECURITY:web_functionalit:58:/'
2025-10-31T16:27:52.792Z:INFO:taskCANopen.c:1821:Added object 0x3284, 1 bytes
2025-10-31T16:27:52.945Z:INFO:taskModbus.c:4526:Address #1: modbus meter vendor : ALF
2025-10-31T16:27:52.957Z:INFO:taskModbus.c:4527:Address #1: modbus meter model : D3001
2025-10-31T16:27:52.968Z:INFO:taskCANopen.c:1821:Added object 0x3285, 18 bytes
2025-10-31T16:27:52.976Z:INFO:taskModbus.c:4528:Address #1: modbus meter revision : V1.03
2025-10-31T16:27:52.988Z:INFO:taskModbus.c:4529:Address #1: modbus meter meterNumber : 22391493
2025-10-31T16:27:52.996Z:USER:taskModbus.c:936:Socket_1 Meter(1): meter type DZG_REALLIN found
2025-10-31T16:27:53.007Z:SECURITY:web_functionalit:58:Changed '20F1_07' from '******' => '******'
2025-10-31T16:27:53.019Z:SECURITY:web_functionalit:63:Changed '20f1_0e' from 0 => 2
2025-10-31T16:27:53.105Z:USER:comFaults.c:386:Socket #1: Error 105 resolved
2025-10-31T16:27:53.132Z:INFO:taskCANopen.c:1821:Added object 0x3286, 18 bytes
2025-10-31T16:27:53.304Z:INFO:taskCANopen.c:1821:Added object 0x3287, 18 bytes
2025-10-31T16:27:53.468Z:INFO:taskCANopen.c:1821:Added object 0x3288, 18 bytes
2025-10-31T16:27:53.488Z:USER:taskModbus.c:1107:Socket_1 Meter(1): first meter update, Multiple phase installation
2025-10-31T16:27:53.503Z:SECURITY:web_functionalit:63:Changed '2126_00' from 0 => 2
2025-10-31T16:27:53.511Z:INFO:taskMain.c:1324:Authorisation method COM unit via CAN
2025-10-31T16:27:53.523Z:INFO:taskMain.c:1724:Socket #1: recovered INOPERATIVE
2025-10-31T16:27:53.554Z:INFO:taskMaster.c:4957:Socket #1: state main : INOPERATIVE
2025-10-31T16:27:53.589Z:INFO:taskMaster.c:1575:Socket #1: no open transaction
2025-10-31T16:27:53.613Z:INFO:taskMaster.c:4979:Socket #1: state led : INOPERATIVE
2025-10-31T16:27:53.625Z:USER:taskMaster.c:1359:NFC version: ICU NFC 243B (v3) v3.1-531
2025-10-31T16:27:53.656Z:INFO:taskMaster.c:4957:Socket #1: state main : AVAILABLE
2025-10-31T16:27:53.664Z:INFO:taskCANopen.c:1821:Added object 0x3289, 18 bytes
2025-10-31T16:27:53.671Z:INFO:taskMain.c:6440:Socket #1: active tag cleared
2025-10-31T16:27:53.753Z:WARNING:web_functionali:139:Could not find prop dwId 2077.00
2025-10-31T16:27:53.765Z:SECURITY:web_functionalit:58:Changed '205D_00' from 'nl_NL' => 'en_GB'
2025-10-31T16:27:53.773Z:WARNING:scn_communicatio:75:SCN: Not enough sockets for an SCN!
2025-10-31T16:27:53.785Z:INFO:station.c:197:Loadbalancing mode set to STATICLB_OFF_ACTIVELB_OFF [0]
2025-10-31T16:27:53.796Z:SECURITY:web_functionalit:70:Changed '2067_00' from 25.000000 => 16.000000
2025-10-31T16:27:53.804Z:SECURITY:web_functionalit:70:Changed '2062_00' from 16.000000 => 32.000000
2025-10-31T16:27:53.816Z:WARNING:scn_communicatio:75:SCN: Not enough sockets for an SCN!
2025-10-31T16:27:53.828Z:SECURITY:web_functionalit:58:Changed '2063_00' from 'A0640314' => ''
2025-10-31T16:27:53.835Z:SECURITY:web_functionalit:63:Changed '2070_00' from 0 => 1
2025-10-31T16:27:53.843Z:SECURITY:web_functionalit:63:Changed '2114_00' from 0 => 2
2025-10-31T16:27:53.851Z:SECURITY:web_functionalit:63:Changed '2137_00' from 0 => 2
2025-10-31T16:27:53.859Z:INFO:taskCANopen.c:1821:Added object 0x328a, 33 bytes
2025-10-31T16:27:53.871Z:INFO:station.c:184:Active station current set to 32.0A max
2025-10-31T16:27:53.878Z:SECURITY:web_functionalit:63:Changed '2171_00' from 1 => 0
2025-10-31T16:27:53.890Z:INFO:taskMaster.c:4979:Socket #1: state led : AVAILABLE
2025-10-31T16:27:54.019Z:INFO:taskCANopen.c:1821:Added object 0x328b, 65 bytes
2025-10-31T16:27:54.179Z:INFO:taskCANopen.c:1821:Added object 0x328c, 4 bytes
2025-10-31T16:27:54.335Z:INFO:taskCANopen.c:1821:Added object 0x3290, 4 bytes
2025-10-31T16:27:54.492Z:INFO:taskCANopen.c:1821:Added object 0x3291, 1 bytes
2025-10-31T16:27:54.652Z:INFO:taskCANopen.c:1821:Added object 0x3295, 30 bytes
2025-10-31T16:27:54.703Z:INFO:taskMain.c:1419:Socket #1: main state: AVAILABLE, CP: 0.0/0.0, no tag
2025-10-31T16:27:54.820Z:INFO:taskCANopen.c:1821:Added object 0x3296, 16 bytes
2025-10-31T16:27:54.996Z:INFO:taskCANopen.c:1821:Added object 0x3297, 16 bytes
2025-10-31T16:27:55.164Z:INFO:taskCANopen.c:1821:Added object 0x3298, 18 bytes
2025-10-31T16:27:55.335Z:INFO:taskCANopen.c:1821:Added object 0x3299, 18 bytes
2025-10-31T16:27:55.496Z:INFO:web_functionali:159:Executing command: 'reboot'
2025-10-31T16:27:55.507Z:INFO:taskCANopen.c:1821:Added object 0x3300, 18 bytes
2025-10-31T16:27:55.605Z:SECURITY:application.c:792:reset: requested, going down..
2025-10-31T16:27:55.691Z:INFO:taskCANopen.c:1821:Added object 0x3700, 132 bytes
2025-10-31T16:27:55.851Z:INFO:taskCANopen.c:1821:Added object 0x4217, 1 bytes
2025-10-31T16:27:56.015Z:INFO:taskCANopen.c:1821:Added object 0x4218, 1 bytes
2025-10-31T16:27:56.175Z:INFO:taskCANopen.c:1821:Added object 0x5217, 1 bytes
2025-10-31T16:27:56.347Z:INFO:taskCANopen.c:1821:Added object 0x5218, 1 bytes
2025-10-31T16:27:56.511Z:INFO:taskCANopen.c:1821:Added object 0x5230, 1 bytes
2025-10-31T16:27:56.542Z:INFO:taskCANopen.c:1787:Updated object 0x204f, 2 bytes
2025-10-31T16:27:56.582Z:INFO:taskCANopen.c:1787:Updated object 0x2050, 21 bytes
2025-10-31T16:27:56.628Z:INFO:taskCANopen.c:1787:Updated object 0x2053, 21 bytes
2025-10-31T16:27:56.687Z:INFO:taskCANopen.c:1787:Updated object 0x205d, 9 bytes
2025-10-31T16:27:56.726Z:INFO:taskCANopen.c:1787:Updated object 0x2061, 2 bytes
2025-10-31T16:27:56.769Z:INFO:taskCANopen.c:1787:Updated object 0x2062, 4 bytes
2025-10-31T16:27:56.808Z:INFO:taskCANopen.c:1787:Updated object 0x2063, 21 bytes
2025-10-31T16:27:56.855Z:INFO:taskCANopen.c:1787:Updated object 0x2067, 4 bytes
2025-10-31T16:27:56.914Z:INFO:taskCANopen.c:1787:Updated object 0x2070, 1 bytes
2025-10-31T16:27:56.972Z:INFO:taskCANopen.c:1787:Updated object 0x2076, 51 bytes
2025-10-31T16:27:57.019Z:INFO:taskCANopen.c:1787:Updated object 0x2079, 18 bytes
2025-10-31T16:27:57.078Z:INFO:taskCANopen.c:1787:Updated object 0x207b, 18 bytes
2025-10-31T16:27:57.128Z:INFO:taskCANopen.c:1787:Updated object 0x207c, 18 bytes
2025-10-31T16:27:57.179Z:INFO:taskCANopen.c:1787:Updated object 0x207d, 18 bytes
2025-10-31T16:27:57.226Z:INFO:taskCANopen.c:1787:Updated object 0x207e, 18 bytes
2025-10-31T16:27:57.277Z:INFO:taskCANopen.c:1787:Updated object 0x207f, 18 bytes
2025-10-31T16:27:57.328Z:INFO:taskCANopen.c:1787:Updated object 0x2080, 18 bytes
2025-10-31T16:27:57.394Z:INFO:taskCANopen.c:1787:Updated object 0x2096, 2 bytes
2025-10-31T16:27:57.628Z:INFO:taskCANopen.c:1787:Updated object 0x20f0, 1142 bytes
2025-10-31T16:27:57.746Z:INFO:modem.c:2525:Check PIN
2025-10-31T16:27:57.855Z:INFO:taskCANopen.c:1787:Updated object 0x20f1, 1142 bytes
2025-10-31T16:27:57.996Z:INFO:taskCANopen.c:1787:Updated object 0x2114, 1 bytes
2025-10-31T16:27:58.050Z:INFO:taskCANopen.c:1787:Updated object 0x2126, 1 bytes
2025-10-31T16:27:58.113Z:INFO:taskCANopen.c:1787:Updated object 0x2136, 2 bytes
2025-10-31T16:27:58.148Z:INFO:taskCANopen.c:1787:Updated object 0x2137, 1 bytes
2025-10-31T16:27:58.261Z:INFO:taskCANopen.c:1787:Updated object 0x2171, 1 bytes
2025-10-31T16:27:58.363Z:INFO:taskCANopen.c:1787:Updated object 0x21a1, 30 bytes
2025-10-31T16:27:58.460Z:INFO:taskCANopen.c:1787:Updated object 0x2218, 1 bytes
2025-10-31T16:27:59.875Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:28:00.835Z:WARNING:modem.c:2562:SIM error
2025-10-31T16:28:00.941Z:WARNING:modem.c:2562:SIM error
2025-10-31T16:28:01.046Z:WARNING:modem.c:2562:SIM error
2025-10-31T16:28:01.152Z:WARNING:modem.c:2562:SIM error
2025-10-31T16:28:01.257Z:INFO:modem.c:2572:Check PIN failed
2025-10-31T16:28:01.316Z:ERROR:modem.c:2146:Set minimum func failed
2025-10-31T16:28:01.343Z:ERROR:modem.c:2146:Set RAT failed
2025-10-31T16:28:01.367Z:ERROR:modem.c:2146:Set normal func failed
2025-10-31T16:28:01.394Z:ERROR:modem.c:2146:Wait start confirm failed
2025-10-31T16:28:02.410Z:ERROR:modem.c:3071:Set RAT failed
2025-10-31T16:28:02.429Z:INFO:modem.c:3291:Get other info
2025-10-31T16:28:06.835Z:INFO:modem.c:1075:Modem power off timeout
2025-10-31T16:28:18.695Z:RESET:application.c:414:==========================================
2025-10-31T16:28:18.703Z:INFO:application.c:421:build: Oct 27 2025 13:58:28
2025-10-31T16:28:18.710Z:INFO:application.c:422:version: 7.3.0-4377
2025-10-31T16:28:18.718Z:INFO:application.c:423:compiler: gcc 9.3.1
2025-10-31T16:28:18.726Z:INFO:application.c:285:fwu state inactive
2025-10-31T16:28:18.734Z:INFO:application.c:292:Bootloader version 2.2.2
2025-10-31T16:28:19.148Z:USER:taskCANopen.c:241:Persistent configuration retrieved, 284 items
2025-10-31T16:28:19.160Z:INFO:application.c:328:FLASH read protection 0xcc level 2 (permanent)
2025-10-31T16:28:19.171Z:INFO:application.c:364:System boot #2, cause Software reset
2025-10-31T16:28:19.179Z:INFO:board_ng9xx.c:1602:Registered timeout getHardware
2025-10-31T16:28:20.890Z:INFO:bspMotors.c:616:Socket #1: Timeout while waiting for Cover motor
2025-10-31T16:28:20.949Z:INFO:board_ng9xx.c:1629:Unregistered timeout getHardware
2025-10-31T16:28:20.957Z:INFO:application.c:510:ST MCU ID......................20036419
2025-10-31T16:28:20.968Z:INFO:application.c:511:Device ID:.....................004000203531510532353530
2025-10-31T16:28:20.976Z:INFO:application.c:512:Object ID:.....................ACE0640314
2025-10-31T16:28:20.988Z:INFO:application.c:513:#Sockets.......................1
2025-10-31T16:28:20.996Z:INFO:application.c:514:MAC address eeprom.............not available
2025-10-31T16:28:21.003Z:INFO:application.c:515:Configuration eeprom...........available
2025-10-31T16:28:21.015Z:INFO:application.c:517:Flash EEPROM...................available: manuf. 0x00c2, id 0x2016 (8 MB)
2025-10-31T16:28:21.027Z:INFO:application.c:520:Temperature sensor.............available (20.0/25.2 °C)
2025-10-31T16:28:21.039Z:INFO:application.c:521:Accelerometer/tilt sensor......not available
2025-10-31T16:28:21.046Z:INFO:application.c:522:Ambient light/proximity sensor.not available
2025-10-31T16:28:21.058Z:INFO:application.c:523:Real time clock................available
2025-10-31T16:28:21.066Z:INFO:application.c:524:Mobile network modem...........Autodetect (enabled)
2025-10-31T16:28:21.078Z:INFO:application.c:525:Ethernet PHY...................available
2025-10-31T16:28:21.285Z:INFO:application.c:534:#1 Control Pilot circuit.......available (0.2/-11.7 Volts)
2025-10-31T16:28:21.296Z:INFO:application.c:535:#1 Proximity Pin circuit.......available (100000 Ohms)
2025-10-31T16:28:21.308Z:INFO:application.c:536:#1 Socket motor................available
2025-10-31T16:28:21.316Z:INFO:application.c:537:#1 Cover motor.................not available
2025-10-31T16:28:21.324Z:INFO:application.c:538:#1 Auxiliary I/O...............not available
2025-10-31T16:28:21.335Z:INFO:application.c:539:#1 Button input................not available
2025-10-31T16:28:21.343Z:INFO:application.c:540:#1 NFC reader..................not available
2025-10-31T16:28:21.355Z:INFO:application.c:541:#1 Emergency relays............available
2025-10-31T16:28:21.363Z:INFO:application.c:560:-12V power supply..............available
2025-10-31T16:28:21.375Z:INFO:application.c:561:Smart meter P1 port interface..available
2025-10-31T16:28:21.382Z:INFO:application.c:562:Smart meter Suspend input......not available
2025-10-31T16:28:21.390Z:INFO:application.c:563:Smart meter external Modbus....available
2025-10-31T16:28:21.402Z:INFO:application.c:564:Energy meter ModBus interface..available
2025-10-31T16:28:21.410Z:INFO:application.c:565:Display user interface.........available
2025-10-31T16:28:21.421Z:INFO:application.c:566:PWM Buzzer.....................not available
2025-10-31T16:28:21.429Z:INFO:application.c:569:Auxiliary Board................supported
2025-10-31T16:28:21.437Z:INFO:application.c:570:Auxiliary Board revision.......D
2025-10-31T16:28:21.449Z:INFO:application.c:572:Powerboard revision/assy.......GUNKNOWN (32.0A)
2025-10-31T16:28:21.457Z:INFO:application.c:573:Controllerboard revision/assy..L7
2025-10-31T16:28:21.464Z:INFO:application.c:574:Powerboard relay type..........LATCHING_REVERSED
2025-10-31T16:28:21.476Z:INFO:application.c:592:Operational time ..............0D 00H
2025-10-31T16:28:21.492Z:INFO:db_common.c:147:Initializing all databases..
2025-10-31T16:28:21.929Z:INFO:db_base.c:1325:Initialized Transaction db (firstItem=0x00000000, lastItem=0x00001877)
2025-10-31T16:28:21.941Z:INFO:db_base.c:1325:Initialized LocalList db (firstItem=0x00000000, lastItem=0x00000000)
2025-10-31T16:28:21.957Z:INFO:db_base.c:1325:Initialized WhiteList db (firstItem=0x00000000, lastItem=0x00000041)
2025-10-31T16:28:21.972Z:INFO:db_base.c:1325:Initialized ChargingProfile db (firstItem=0x00000000, lastItem=0x000001b1)
2025-10-31T16:28:22.003Z:INFO:db_chargingprofi:75:Defragmented (#0/0, 19ms)
2025-10-31T16:28:22.011Z:INFO:db_chargingprofi:19:Max 45 charging profiles of 100 periods
2025-10-31T16:28:22.023Z:INFO:db_base.c:1325:Initialized Domain db (firstItem=0x00000000, lastItem=0x00000070)
2025-10-31T16:28:22.039Z:USER:ocpp.c:187:Init OCPP for ocpp1.6
2025-10-31T16:28:22.046Z:INFO:board_ng9xx.c:1602:Registered timeout BootNotification
2025-10-31T16:28:22.082Z:INFO:featureKeys.c:78:Unlocked Features: SCN,RFID-reader,4G (80010101)
2025-10-31T16:28:22.093Z:INFO:taskMain.c:599:Socket #1: Authorisation method COM unit via CAN
2025-10-31T16:28:22.101Z:INFO:taskMain.c:602:Socket #1: SocketType Mennekes
2025-10-31T16:28:22.109Z:INFO:taskMain.c:606:Socket #1: startup delay 5 s
2025-10-31T16:28:22.121Z:INFO:board_ng9xx.c:1602:Registered timeout NUVVE
2025-10-31T16:28:22.128Z:INFO:board_ng9xx.c:1602:Registered timeout NUVVE
2025-10-31T16:28:22.148Z:USER:EVsimulator.c:210:EV simulator initialised
2025-10-31T16:28:22.156Z:USER:taskMaster.c:1050:ocpp1.6 Smart Charging Mode
2025-10-31T16:28:22.371Z:INFO:bspEthernet.c:165:Ethernet PHY LAN8710@0x00
2025-10-31T16:28:22.386Z:USER:bspEthernet.c:238:ETH PHY OK
2025-10-31T16:28:22.390Z:INFO:bspEthernet.c:217:MACAddress: [26:64:44:07:10:35]
2025-10-31T16:28:22.402Z:INFO:modem.c:1124:Modem state Idle->InitHw
2025-10-31T16:28:22.406Z:INFO:scn.c:686:Loadbalancing: Feature enabled
2025-10-31T16:28:22.414Z:INFO:scn.c:687:SCN: Feature enabled [Off]
2025-10-31T16:28:22.421Z:WARNING:scn_communicatio:75:SCN: Not enough sockets for an SCN!
2025-10-31T16:28:22.441Z:INFO:taskMain.c:1294:contactorstabletime : 50
2025-10-31T16:28:22.449Z:INFO:taskMain.c:1295:HFContactorSwitchTime : 60
2025-10-31T16:28:22.460Z:INFO:taskLeds.c:226:LED UI initialized OK
2025-10-31T16:28:22.468Z:INFO:taskMain.c:6180:Socket #1: DSC initialised
2025-10-31T16:28:22.476Z:INFO:station.c:184:Active station current set to 32.0A max
2025-10-31T16:28:22.488Z:INFO:taskMain.c:6504:Socket #1: PP 34464 Ohm (0 A)
2025-10-31T16:28:22.503Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.0% (6.0 A)
2025-10-31T16:28:22.511Z:INFO:comConnect.c:295:Connectivity state: STARTUP
2025-10-31T16:28:22.562Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-10-31T16:28:23.062Z:INFO:taskModbus.c:4526:Address #1: modbus meter vendor : ALF
2025-10-31T16:28:23.074Z:INFO:taskModbus.c:4527:Address #1: modbus meter model : D3001
2025-10-31T16:28:23.082Z:INFO:taskModbus.c:4528:Address #1: modbus meter revision : V1.03
2025-10-31T16:28:23.093Z:INFO:taskModbus.c:4529:Address #1: modbus meter meterNumber : 22391493
2025-10-31T16:28:23.105Z:USER:taskModbus.c:936:Socket_1 Meter(1): meter type DZG_REALLIN found
2025-10-31T16:28:23.429Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:28:23.437Z:INFO:taskCANopen.c:1212:Persistent memory not cached
2025-10-31T16:28:23.445Z:INFO:taskNFCreader.c:579:Port #0 switch NFC power on
2025-10-31T16:28:23.503Z:INFO:taskMain.c:1419:Socket #1: main state: BOOTING, CP: 0.0/0.0, no tag
2025-10-31T16:28:23.539Z:INFO:taskCANopen.c:2020:CanOpen EEPROM cache size: 284, got 284 objects <284,0>
2025-10-31T16:28:23.566Z:INFO:taskCANopen.c:1787:Updated object 0x2056, 4 bytes
2025-10-31T16:28:23.601Z:USER:taskModbus.c:1107:Socket_1 Meter(1): first meter update, Multiple phase installation
2025-10-31T16:28:23.855Z:INFO:taskCANopen.c:1787:Updated object 0x2180, 28 bytes
2025-10-31T16:28:24.093Z:USER:bspEthernet.c:342:Mode: 100Mb/s full duplex
2025-10-31T16:28:24.101Z:INFO:taskTCPIP.c:958:Network Cable is now connected
2025-10-31T16:28:24.652Z:USER:taskMaster.c:1329:Node #1, version 7.3.0-4377
2025-10-31T16:28:24.906Z:INFO:taskTCPIP.c:1617: IP address assigned by DHCP
2025-10-31T16:28:24.914Z:INFO:taskTCPIP.c:1645:Network interface is up
2025-10-31T16:28:24.921Z:INFO:taskTCPIP.c:1654: IP : 192.168.178.184
2025-10-31T16:28:24.929Z:INFO:taskTCPIP.c:1655: Netmask : 255.255.255.0
2025-10-31T16:28:24.937Z:INFO:taskTCPIP.c:1656: Gateway : 192.168.178.1
2025-10-31T16:28:24.945Z:INFO:taskTCPIP.c:1657: DNS1 : 192.168.178.1
2025-10-31T16:28:24.953Z:INFO:taskTCPIP.c:1658: DNS2 : 208.67.220.220
2025-10-31T16:28:24.960Z:INFO:taskTCPIP.c:512:Starting mDNS on interface al
2025-10-31T16:28:24.968Z:INFO:taskTCPIP.c:512:Starting Webserver on interface al
2025-10-31T16:28:24.980Z:INFO:taskTCPIP.c:512:Starting Modbus on interface al
2025-10-31T16:28:24.988Z:INFO:taskTCPIP.c:512:Starting P1 on interface al
2025-10-31T16:28:24.996Z:INFO:taskTCPIP.c:512:Starting SCN on interface al
2025-10-31T16:28:25.003Z:INFO:taskTCPIP.c:413:default network set to 'al'
2025-10-31T16:28:25.011Z:INFO:taskWebServer.c:238:WebServer state WAIT_FOR_NETWORK -> SETUP
2025-10-31T16:28:25.046Z:USER:taskWebServer.c:360:WebServer started on port 443
2025-10-31T16:28:25.054Z:INFO:taskWebServer.c:238:WebServer state SETUP -> AVAILABLE
2025-10-31T16:28:25.449Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:28:25.515Z:INFO:taskCANopen.c:1787:Updated object 0x207e, 18 bytes
2025-10-31T16:28:25.542Z:INFO:taskCANopen.c:1787:Updated object 0x207f, 18 bytes
2025-10-31T16:28:27.476Z:INFO:comConnect.c:1107:Connecting wired to: ws://ws.evc-net.com/VAN_01971, prio #1
2025-10-31T16:28:27.496Z:USER:taskMaster.c:1359:NFC version: ICU NFC 243B (v3) v3.1-531
2025-10-31T16:28:27.503Z:INFO:taskNFCreader.c:115:Port #0 version response: "ICU NFC 243B (v3) v3.1-531"
2025-10-31T16:28:27.546Z:INFO:comConnect.c:664:connection attempt 1/3
2025-10-31T16:28:27.574Z:INFO:comConnect.c:295:Connectivity state: INITIALISING
2025-10-31T16:28:27.613Z:INFO:comConnect.c:295:Connectivity state: WIRED
2025-10-31T16:28:27.648Z:INFO:taskTCPIP.c:1526:'al' is configured as default internet connection.
2025-10-31T16:28:27.679Z:INFO:taskTCPIP.c:1543:Renew DHCP leash for interface 'al'.
2025-10-31T16:28:27.707Z:USER:comConnect.c:383:wired connect
2025-10-31T16:28:27.726Z:INFO:taskNFCreader.c:131:Port #0 ICU NFC reader BL3 v3.1, 1 LEDs
2025-10-31T16:28:27.738Z:INFO:taskNFCreader.c:132:Port #0 reader model: Giro-e
2025-10-31T16:28:27.746Z:INFO:websockets.c:451:Connected to Socket ws.evc-net.com:80
2025-10-31T16:28:27.757Z:INFO:websockets.c:2363:WS timeout: 10000 ms
2025-10-31T16:28:27.765Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:28:27.824Z:INFO:websockets.c:824:WebSocket upgrade successful
2025-10-31T16:28:27.843Z:USER:taskOCPP.c:464:Back office connection available
2025-10-31T16:28:28.101Z:SECURITY:httpd_login.c:155:WebClient RadomskiR connected (account: admin)
2025-10-31T16:28:28.199Z:USER:application.c:718:Initialisation done
2025-10-31T16:28:29.710Z:INFO:modem.c:1124:Modem state InitHw->InitModem
2025-10-31T16:28:29.718Z:INFO:modem.c:1296:Reset delay 2s
2025-10-31T16:28:30.507Z:INFO:taskMaster.c:1137:Socket #1 has a Modbus meter
2025-10-31T16:28:30.515Z:INFO:updatefirmware.c:52:BL FWU_STATUS_INACTIVE -> int IDLE
2025-10-31T16:28:30.527Z:INFO:taskMain.c:1673:Socket #1: recovered AVAILABLE
2025-10-31T16:28:30.535Z:USER:taskMaster.c:1164:1 NFC readers found
2025-10-31T16:28:30.558Z:INFO:taskMaster.c:1575:Socket #1: no open transaction
2025-10-31T16:28:30.597Z:INFO:smartMeter.c:80:Set phases: (L1, L2, L3)->(L1, L2, L3)
2025-10-31T16:28:30.605Z:INFO:taskMaster.c:4957:Socket #1: state main : AVAILABLE
2025-10-31T16:28:30.621Z:INFO:taskMain.c:6440:Socket #1: active tag cleared
2025-10-31T16:28:30.664Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-10-31T16:28:30.671Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-10-31T16:28:30.679Z:INFO:taskMaster.c:4979:Socket #1: state led : AVAILABLE
2025-10-31T16:28:30.738Z:INFO:taskMaster.c:6376:Socket #1: no schedule
2025-10-31T16:28:30.746Z:USER:taskMaster.c:6402:Socket #1: external current limit 16.0 A
2025-10-31T16:28:30.757Z:INFO:station.c:97:station external max - new value: 99.9A
2025-10-31T16:28:30.765Z:INFO:comFaults.c:482:Reset fault status
2025-10-31T16:28:30.773Z:USER:taskMaster.c:1359:NFC version: ICU NFC 243B (v3) v3.1-531
2025-10-31T16:28:31.550Z:INFO:taskMain.c:1419:Socket #1: main state: AVAILABLE, CP: 0.0/0.0, no tag
2025-10-31T16:28:31.714Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x50)
2025-10-31T16:28:31.726Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-31T16:28:31.839Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-31T16:28:32.851Z:COM:ocpp_rpc.c:704:-> [2,"1","BootNotification",{"chargePointVendor":"Alfen BV","chargePointModel":
2025-10-31T16:28:32.851Z:COM:ocpp_rpc.c:704:"NG910-60583","chargePointSerialNumber":"ACE0640314","chargeBoxSerialNumber":"VA
2025-10-31T16:28:32.851Z:COM:ocpp_rpc.c:704:N_01971","firmwareVersion":"7.3.0-4377"}]
2025-10-31T16:28:32.914Z:COM:ocpp_rpc.c:1297:<- [3,"1",{"status":"Accepted","currentTime":"2025-10-31T16:28:33Z","interval":3
2025-10-31T16:28:32.914Z:COM:ocpp_rpc.c:1297:600}]
2025-10-31T16:28:33.910Z:USER:modem.c:3611:Modem type: Quectel BG95-M3
2025-10-31T16:28:33.929Z:INFO:modem.c:3090:Check if modem responds
2025-10-31T16:28:33.968Z:INFO:modem.c:2977:Set flow control (on)
2025-10-31T16:28:34.136Z:INFO:modem.c:3130:Set type of logging
2025-10-31T16:28:39.453Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:28:39.523Z:SECURITY:taskWebClient.c:446:Received unauthorized request, so removing client
2025-10-31T16:28:39.535Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-31T16:28:39.582Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-31T16:28:40.765Z:INFO:comFaults.c:1075:#phases: socket #1 ''->'L1L2L3'
2025-10-31T16:28:41.324Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:28:41.957Z:SECURITY:httpd_login.c:155:WebClient RadomskiR connected (account: admin)
2025-10-31T16:28:43.011Z:COM:ocpp_rpc.c:704:-> [2,"2","StatusNotification",{"connectorId":0,"errorCode":"NoError","status":"
2025-10-31T16:28:43.011Z:COM:ocpp_rpc.c:704:Available"}]
2025-10-31T16:28:43.042Z:COM:ocpp_rpc.c:1297:<- [3,"2",{}]
2025-10-31T16:28:43.050Z:COM:ocpp_rpc.c:704:-> [2,"3","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":"
2025-10-31T16:28:43.050Z:COM:ocpp_rpc.c:704:Available"}]
2025-10-31T16:28:43.074Z:COM:ocpp_rpc.c:1297:<- [3,"3",{}]
2025-10-31T16:28:52.613Z:INFO:modem.c:2525:Check PIN
2025-10-31T16:28:56.390Z:WARNING:modem.c:2562:SIM error
2025-10-31T16:29:00.265Z:WARNING:modem.c:2562:SIM error
2025-10-31T16:29:02.281Z:INFO:taskWifi.c:671:WiFi Module: Not Initialized --> Running
2025-10-31T16:29:03.972Z:INFO:wifi.c:451:Successfully started AP <ACE0640314> ip<192.168.50.10>
2025-10-31T16:29:03.984Z:INFO:taskWifi.c:982:Start WiFi AP
2025-10-31T16:29:03.992Z:WARNING:taskWifi.c:1061:Wifi config is not valid
2025-10-31T16:29:04.000Z:INFO:taskWifi.c:678:SoftAP: Not Initialized --> Enabled
2025-10-31T16:29:04.007Z:INFO:taskWifi.c:685:STA: Not Initialized --> Not Configured
2025-10-31T16:29:04.144Z:WARNING:modem.c:2562:SIM error
2025-10-31T16:29:08.023Z:WARNING:modem.c:2562:SIM error
2025-10-31T16:29:08.128Z:INFO:modem.c:2572:Check PIN failed
2025-10-31T16:29:23.128Z:INFO:modem.c:3291:Get other info
2025-10-31T16:29:56.238Z:WARNING:modem.c:2725:AT+CSQ, invalid value(99)
2025-10-31T16:30:15.250Z:SECURITY:web_functionalit:63:Changed '20f0_0e' from 1 => 0
2025-10-31T16:30:15.261Z:SECURITY:web_functionalit:63:Changed '20f1_0e' from 2 => 0
2025-10-31T16:30:15.996Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:30:16.222Z:INFO:taskCANopen.c:1787:Updated object 0x20f0, 1142 bytes
2025-10-31T16:30:16.394Z:INFO:taskCANopen.c:1787:Updated object 0x20f1, 1142 bytes
2025-10-31T16:30:17.265Z:SECURITY:web_functionalit:68:Changed '2187_00' from 0 => 1761928217869
2025-10-31T16:30:17.996Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:30:18.250Z:INFO:taskCANopen.c:1787:Updated object 0x2187, 8 bytes
2025-10-31T16:30:28.222Z:INFO:modem.c:3313:Signal strength : Unknown
2025-10-31T16:30:28.230Z:INFO:modem.c:3315:Radio Access Tech : 4G
2025-10-31T16:30:28.238Z:INFO:modem.c:3316:Registration mode : Disabled
2025-10-31T16:30:28.246Z:INFO:modem.c:3317:Registration status: Not registered
2025-10-31T16:30:28.253Z:INFO:modem.c:3318:Operator : 0
2025-10-31T16:30:28.261Z:INFO:modem.c:3319:Manufacturer : Quectel
2025-10-31T16:30:28.269Z:INFO:modem.c:3320:Modem module : BG95-M3
2025-10-31T16:30:28.277Z:INFO:modem.c:3321:Modem revision : BG95M3LAR02A03_01.012.01.012
2025-10-31T16:30:28.285Z:INFO:modem.c:3322:Modem IMEI : 864145067568848
2025-10-31T16:30:28.292Z:INFO:modem.c:3323:SIM IMSI :
2025-10-31T16:30:28.300Z:INFO:modem.c:3324:SIM ICCID :
2025-10-31T16:30:28.308Z:INFO:modem.c:3325:Modem supports 2G : yes
2025-10-31T16:30:28.316Z:INFO:modem.c:3326:Modem supports 3G : no
2025-10-31T16:30:28.324Z:INFO:modem.c:3327:Modem supports 4G : yes
2025-10-31T16:30:28.375Z:INFO:modem.c:3334:Cellinfo : "SEARCH"
2025-10-31T16:30:28.382Z:INFO:modem.c:3356:Modem bootcount : 1
2025-10-31T16:30:28.386Z:ERROR:modem.c:3364:Setup modem Failed
2025-10-31T16:30:28.394Z:INFO:modem.c:1124:Modem state InitModem->Stopping
2025-10-31T16:30:36.917Z:INFO:modem.c:1124:Modem state Stopping->Idle
2025-10-31T16:30:45.789Z:INFO:taskMain.c:5996:Socket #1: Active current 0.0->16.0 due to current limit: Connector-MaxCurrent,
2025-10-31T16:30:45.789Z:INFO:taskMain.c:5996:Simplified-Mode3, ChargingProfile
2025-10-31T16:30:45.851Z:INFO:taskMaster.c:4957:Socket #1: state main : CABLE_CONNECTED
2025-10-31T16:30:45.863Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_A
2025-10-31T16:30:45.871Z:INFO:taskMain.c:6494:Socket #1: CPhigh 12.1 V
2025-10-31T16:30:45.878Z:INFO:taskMain.c:6499:Socket #1: CPlow 12.2 V
2025-10-31T16:30:45.886Z:INFO:taskMain.c:6504:Socket #1: PP 697 Ohm (20 A)
2025-10-31T16:30:45.894Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.6% (16.0 A)
2025-10-31T16:30:45.902Z:INFO:taskMaster.c:4979:Socket #1: state led : CABLE_CONNECTED
2025-10-31T16:30:45.914Z:COM:ocpp_rpc.c:704:-> [2,"4","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":"
2025-10-31T16:30:45.914Z:COM:ocpp_rpc.c:704:Preparing"}]
2025-10-31T16:30:45.933Z:COM:ocpp_rpc.c:1297:<- [3,"4",{}]
2025-10-31T16:30:46.878Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-10-31T16:30:46.886Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-10-31T16:30:46.894Z:INFO:taskMain.c:1419:Socket #1: main state: CABLE_CONNECTED, CP: 9.3/0.9, no tag
2025-10-31T16:30:47.851Z:INFO:taskMaster.c:4957:Socket #1: state main : EV_CONNECTED_UNAUTHORIZED
2025-10-31T16:30:47.863Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-10-31T16:30:48.878Z:INFO:taskMain.c:1419:Socket #1: main state: EV_CONNECTED_UNAUTHORIZED, CP: 9.3/0.9, no tag
2025-10-31T16:30:50.250Z:USER:tag.c:1623:Reader 0 Got NFC tag: 04BB29EAFD0F94
2025-10-31T16:30:50.261Z:COM:ocpp_rpc.c:704:-> [2,"5","StatusNotification",{"connectorId":0,"errorCode":"NoError","info":"In
2025-10-31T16:30:50.261Z:COM:ocpp_rpc.c:704:fo: Charge card 04BB29EAFD0F94 detected","status":"Available"}]
2025-10-31T16:30:50.296Z:COM:ocpp_rpc.c:1297:<- [3,"5",{}]
2025-10-31T16:30:50.453Z:USER:taskMaster.c:6931:Socket #1: has reliable metervalue
2025-10-31T16:30:50.460Z:INFO:taskMaster.c:1604:1 cables attached
2025-10-31T16:30:50.500Z:INFO:taskMaster.c:4979:Socket #1: state led : AUTHORISING
2025-10-31T16:30:50.515Z:USER:tag.c:584:Tag 04BB29EAFD0F94 is authorised by white list
2025-10-31T16:30:50.550Z:USER:taskMaster.c:1914:Multiple cables attached, prioritizing socket #1
2025-10-31T16:30:50.597Z:USER:board_ng9xx.c:5068:Socket #1: lock socket motor
2025-10-31T16:30:50.605Z:INFO:taskMaster.c:4957:Socket #1: state main : EV_CONNECTED_AUTHORIZED
2025-10-31T16:30:51.214Z:INFO:taskMaster.c:7497:New charging session started, metervalue=5540316.000
2025-10-31T16:30:51.230Z:INFO:db_transaction.c:16:Added TransactionStart for socket 1 at 0x0000188d (ts: 2025-10-31 16:30:50)
2025-10-31T16:30:51.253Z:INFO:taskMaster.c:4979:Socket #1: state led : EV_CONNECTED
2025-10-31T16:30:51.261Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T16:30:51.324Z:INFO:taskMaster.c:6353:Socket #1: external current limit 15.9 A until 2025-10-31T23:00:00Z
2025-10-31T16:30:51.335Z:USER:taskMaster.c:6402:Socket #1: external current limit 15.9 A
2025-10-31T16:30:51.347Z:INFO:taskMain.c:5996:Socket #1: Active current 16.0->15.9 due to current limit: ChargingProfile
2025-10-31T16:30:51.570Z:COM:ocpp_rpc.c:704:-> [2,"6","StartTransaction",{"timestamp":"2025-10-31T16:30:50Z","connectorId":1
2025-10-31T16:30:51.570Z:COM:ocpp_rpc.c:704:,"meterStart":5540316,"idTag":"04BB29EAFD0F94"}]
2025-10-31T16:30:51.609Z:INFO:taskMain.c:1417:Socket #1: main state: EV_CONNECTED_AUTHORIZED, CP: 9.3/9.3, tag: 04BB29EAFD0F94
2025-10-31T16:30:51.671Z:COM:ocpp_rpc.c:1297:<- [3,"6",{"idTagInfo":{"status":"Invalid"},"transactionId":290513379}]
2025-10-31T16:30:51.683Z:INFO:db_transaction.c:16:Updated TransactionStart for socket 1 at 0x0000188d (ts: 2025-10-31 16:30:50)
2025-10-31T16:30:51.695Z:INFO:taskMaster.c:2868:Socket #1: tag marked invalid
2025-10-31T16:30:51.703Z:INFO:taskMain.c:938:Socket #1: charging session status set active
2025-10-31T16:30:51.714Z:INFO:taskMaster.c:4957:Socket #1: state main : WAIT_FOR_START_METERVALUE
2025-10-31T16:30:51.726Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_PREPARING
2025-10-31T16:30:51.734Z:USER:tag.c:1830:Tag 04BB29EAFD0F94 is rejected by server, white list updated
2025-10-31T16:30:51.746Z:COM:ocpp_rpc.c:704:-> [2,"7","StatusNotification",{"connectorId":1,"errorCode":"NoError","info":"Sm
2025-10-31T16:30:51.746Z:COM:ocpp_rpc.c:704:artCharging(16A)","status":"Preparing"}]
2025-10-31T16:30:51.773Z:COM:ocpp_rpc.c:1297:<- [3,"7",{}]
2025-10-31T16:30:51.828Z:COM:ocpp_rpc.c:704:-> [2,"8","MeterValues",{"connectorId":1,"transactionId":290513379,"meterValue":
2025-10-31T16:30:51.828Z:COM:ocpp_rpc.c:704:[{"timestamp":"2025-10-31T16:30:50Z","sampledValue":[{"value":"5540.316","contex
2025-10-31T16:30:51.828Z:COM:ocpp_rpc.c:704:t":"Transaction.Begin","unit":"kWh"}]}]}]
2025-10-31T16:30:51.859Z:COM:ocpp_rpc.c:1297:<- [3,"8",{}]
2025-10-31T16:30:52.808Z:INFO:taskMain.c:1417:Socket #1: main state: WAIT_FOR_START_METERVALUE, CP: 9.3/9.3, tag: 04BB29EAFD0F
2025-10-31T16:30:52.808Z:INFO:taskMain.c:1417:94
2025-10-31T16:30:52.964Z:COM:ocpp_rpc.c:704:-> [2,"9","MeterValues",{"connectorId":1,"transactionId":290513379,"meterValue":
2025-10-31T16:30:52.964Z:COM:ocpp_rpc.c:704:[{"timestamp":"2025-10-31T16:30:52Z","sampledValue":[{"value":"5540.316","contex
2025-10-31T16:30:52.964Z:COM:ocpp_rpc.c:704:t":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"Out
2025-10-31T16:30:52.964Z:COM:ocpp_rpc.c:704:let","unit":"kWh"}]}]}]
2025-10-31T16:30:53.011Z:COM:ocpp_rpc.c:1297:<- [3,"9",{}]
2025-10-31T16:30:54.750Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-10-31T16:30:54.761Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-10-31T16:30:54.773Z:COM:ocpp_rpc.c:704:-> [2,"10","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-31T16:30:54.773Z:COM:ocpp_rpc.c:704:"SuspendedEVSE"}]
2025-10-31T16:30:54.789Z:USER:taskMain.c:5160:Charged 0.0 Wh on invalid ID
2025-10-31T16:30:54.800Z:COM:ocpp_rpc.c:1297:<- [3,"10",{}]
2025-10-31T16:30:54.808Z:INFO:taskMaster.c:4957:Socket #1: state main : INVALID_CARD
2025-10-31T16:30:54.816Z:INFO:taskMaster.c:4979:Socket #1: state led : ERROR
2025-10-31T16:30:55.816Z:INFO:taskMain.c:1417:Socket #1: main state: INVALID_CARD, CP: 9.3/9.3, tag: 04BB29EAFD0F94
2025-10-31T16:31:01.355Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-31T16:31:01.363Z:INFO:db_chargingprofi:26: socket 0
2025-10-31T16:31:01.371Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-31T16:31:01.378Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-31T16:31:01.386Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-31T16:31:01.394Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-31T16:31:01.406Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-31T16:31:01.414Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-31T16:31:01.421Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-31T16:31:01.429Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-31T16:31:01.437Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-31T16:31:01.449Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-31T16:31:01.457Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-31T16:31:01.464Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-31T16:31:01.468Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-31T16:31:01.480Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-31T16:31:01.488Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-31T16:31:01.496Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-31T16:31:01.507Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-31T16:31:01.515Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-31T16:31:01.523Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-31T16:31:01.531Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-31T16:31:01.539Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-31T16:32:19.835Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-10-31T16:33:01.816Z:SECURITY:web_functionalit:70:Changed '2067_00' from 16.000000 => 1.000000
2025-10-31T16:33:01.828Z:SECURITY:web_functionalit:63:Changed '5217_00' from 255 => 5
2025-10-31T16:33:01.835Z:INFO:station.c:240:Changed smart meter: [255->5]
2025-10-31T16:33:01.843Z:SECURITY:web_functionalit:63:Changed '2185_00' from 0 => 1
2025-10-31T16:33:02.062Z:SECURITY:web_functionalit:63:Changed '2064_00' from 0 => 3
2025-10-31T16:33:02.070Z:WARNING:scn_communicatio:75:SCN: Not enough sockets for an SCN!
2025-10-31T16:33:02.082Z:INFO:station.c:197:Loadbalancing mode set to STATICLB_ON_ACTIVELB_ON [3]
2025-10-31T16:33:02.089Z:INFO:station.c:204:Starting Smart Meter: 5
2025-10-31T16:33:02.097Z:INFO:station.c:240:Changed smart meter: [255->5]
2025-10-31T16:33:02.105Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->0.0 due to current limit: Active-LoadBalancing
2025-10-31T16:33:02.121Z:INFO:active_lb.c:308:SMt:(0.0 0.0 0.0)A Free:(1.0 1.0 1.0)A ALB:(0.0 0.0 0.0)A
2025-10-31T16:33:02.128Z:INFO:taskMeter.c:318:Starting smartmeter with protocol P1
2025-10-31T16:33:02.800Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:33:02.835Z:INFO:taskCANopen.c:1787:Updated object 0x2064, 1 bytes
2025-10-31T16:33:02.855Z:INFO:taskCANopen.c:1787:Updated object 0x2067, 4 bytes
2025-10-31T16:33:03.093Z:INFO:taskCANopen.c:1787:Updated object 0x2185, 1 bytes
2025-10-31T16:33:03.281Z:INFO:taskCANopen.c:1787:Updated object 0x5217, 1 bytes
2025-10-31T16:33:03.878Z:SECURITY:web_functionalit:68:Changed '2187_00' from 1761928217869 => 1761928384596
2025-10-31T16:33:04.046Z:INFO:taskCANopen.c:1787:Updated object 0x2187, 8 bytes
2025-10-31T16:33:05.812Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:33:09.312Z:SECURITY:web_functionalit:63:Changed '2064_00' from 3 => 0
2025-10-31T16:33:09.320Z:WARNING:scn_communicatio:75:SCN: Not enough sockets for an SCN!
2025-10-31T16:33:09.328Z:INFO:station.c:197:Loadbalancing mode set to STATICLB_OFF_ACTIVELB_OFF [0]
2025-10-31T16:33:09.339Z:INFO:taskMain.c:5996:Socket #1: Active current 0.0->15.9 due to current limit: ChargingProfile
2025-10-31T16:33:09.835Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:33:09.871Z:INFO:taskCANopen.c:1787:Updated object 0x2064, 1 bytes
2025-10-31T16:33:10.070Z:SECURITY:web_functionalit:70:Changed '2067_00' from 1.000000 => 16.000000
2025-10-31T16:33:10.316Z:SECURITY:web_functionalit:63:Changed '2064_00' from 0 => 3
2025-10-31T16:33:10.324Z:WARNING:scn_communicatio:75:SCN: Not enough sockets for an SCN!
2025-10-31T16:33:10.332Z:INFO:station.c:197:Loadbalancing mode set to STATICLB_ON_ACTIVELB_ON [3]
2025-10-31T16:33:10.343Z:INFO:station.c:204:Starting Smart Meter: 5
2025-10-31T16:33:10.351Z:INFO:station.c:240:Changed smart meter: [255->5]
2025-10-31T16:33:10.359Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->0.0 due to current limit: Active-LoadBalancing
2025-10-31T16:33:10.371Z:INFO:taskMeter.c:318:Starting smartmeter with protocol P1
2025-10-31T16:33:10.859Z:INFO:taskCANopen.c:1787:Updated object 0x2064, 1 bytes
2025-10-31T16:33:10.882Z:INFO:taskCANopen.c:1787:Updated object 0x2067, 4 bytes
2025-10-31T16:33:12.320Z:SECURITY:web_functionalit:68:Changed '2187_00' from 1761928384596 => 1761928392886
2025-10-31T16:33:12.847Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:33:13.105Z:INFO:taskCANopen.c:1787:Updated object 0x2187, 8 bytes
2025-10-31T16:33:22.093Z:INFO:taskMain.c:5996:Socket #1: Active current 0.0->5.2 due to current limit: Active-LoadBalancing
2025-10-31T16:33:34.089Z:INFO:taskMain.c:5996:Socket #1: Active current 5.2->8.3 due to current limit: Active-LoadBalancing
2025-10-31T16:33:34.371Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.8% (8.3 A)
2025-10-31T16:33:46.089Z:INFO:taskMain.c:5996:Socket #1: Active current 8.3->10.2 due to current limit: Active-LoadBalancing
2025-10-31T16:33:46.488Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.9% (10.1 A)
2025-10-31T16:33:51.062Z:SECURITY:web_functionalit:70:Changed '2062_00' from 32.000000 => 25.000000
2025-10-31T16:33:51.074Z:WARNING:scn_communicatio:75:SCN: Not enough sockets for an SCN!
2025-10-31T16:33:51.085Z:INFO:station.c:184:Active station current set to 25.0A max
2025-10-31T16:33:52.039Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:33:52.074Z:INFO:taskCANopen.c:1787:Updated object 0x2062, 4 bytes
2025-10-31T16:33:52.808Z:SECURITY:web_functionalit:68:Changed '2187_00' from 1761928392886 => 1761928433459
2025-10-31T16:33:53.285Z:INFO:taskCANopen.c:1787:Updated object 0x2187, 8 bytes
2025-10-31T16:33:55.050Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:33:58.089Z:INFO:taskMain.c:5996:Socket #1: Active current 10.2->11.3 due to current limit: Active-LoadBalancing
2025-10-31T16:33:58.609Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.8% (11.3 A)
2025-10-31T16:34:10.085Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->12.0 due to current limit: Active-LoadBalancing
2025-10-31T16:34:10.726Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.9% (11.9 A)
2025-10-31T16:34:12.566Z:SECURITY:web_functionalit:70:Changed '2062_00' from 25.000000 => 16.000000
2025-10-31T16:34:12.578Z:WARNING:scn_communicatio:75:SCN: Not enough sockets for an SCN!
2025-10-31T16:34:12.585Z:INFO:station.c:184:Active station current set to 16.0A max
2025-10-31T16:34:13.140Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:34:13.175Z:INFO:taskCANopen.c:1787:Updated object 0x2062, 4 bytes
2025-10-31T16:34:14.312Z:SECURITY:web_functionalit:68:Changed '2187_00' from 1761928433459 => 1761928455032
2025-10-31T16:34:14.386Z:INFO:taskCANopen.c:1787:Updated object 0x2187, 8 bytes
2025-10-31T16:34:16.160Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:34:22.085Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-10-31T16:34:22.843Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-10-31T16:34:34.085Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T16:34:37.644Z:WARNING:taskMain.c:4758:Socket #1: EV disconnected while charging (11.7V)
2025-10-31T16:34:37.679Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_A
2025-10-31T16:34:37.695Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->0.0 due to current limit: Cable
2025-10-31T16:34:37.726Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_TERMINATING
2025-10-31T16:34:37.777Z:INFO:db_transaction.c:16:Added TransactionStop for socket 1 at 0x00001905 (ts: 2242-03-16 12:56:31)
2025-10-31T16:34:37.789Z:INFO:db_transaction.c:16:Updated TransactionStart for socket 1 at 0x0000188d (ts: 2025-10-31 16:30:50)
2025-10-31T16:34:37.804Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-10-31T16:34:37.812Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_VEHICLE
2025-10-31T16:34:37.992Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-10-31T16:34:38.000Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-10-31T16:34:38.007Z:INFO:taskMain.c:6504:Socket #1: PP 34464 Ohm (0 A)
2025-10-31T16:34:38.753Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_TERMINATING, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-10-31T16:34:41.777Z:INFO:taskMaster.c:4957:Socket #1: state main : WAIT_FOR_STOP_METERVALUE
2025-10-31T16:34:42.593Z:INFO:taskMain.c:938:Socket #1: charging session status set inactive
2025-10-31T16:34:42.601Z:USER:board_ng9xx.c:5068:Socket #1: unlock socket motor
2025-10-31T16:34:42.628Z:INFO:taskMaster.c:4957:Socket #1: state main : WAIT_FOR_DISCONNECT
2025-10-31T16:34:42.671Z:INFO:db_transaction.c:16:Updated TransactionStop for socket 1 at 0x00001905 (ts: 2025-10-31 16:34:42)
2025-10-31T16:34:42.703Z:COM:ocpp_rpc.c:704:-> [2,"11","MeterValues",{"connectorId":1,"transactionId":290513379,"meterValue"
2025-10-31T16:34:42.703Z:COM:ocpp_rpc.c:704::[{"timestamp":"2025-10-31T16:34:42Z","sampledValue":[{"value":"5540.316","conte
2025-10-31T16:34:42.703Z:COM:ocpp_rpc.c:704:xt":"Transaction.End","unit":"kWh"}]}]}]
2025-10-31T16:34:42.738Z:INFO:taskMaster.c:4979:Socket #1: state led : AVAILABLE
2025-10-31T16:34:42.746Z:INFO:taskMaster.c:4957:Socket #1: state main : AVAILABLE
2025-10-31T16:34:42.753Z:COM:ocpp_rpc.c:1297:<- [3,"11",{}]
2025-10-31T16:34:42.761Z:INFO:taskMain.c:6440:Socket #1: active tag cleared
2025-10-31T16:34:42.773Z:COM:ocpp_rpc.c:704:-> [2,"12","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-31T16:34:42.773Z:COM:ocpp_rpc.c:704:"Available"}]
2025-10-31T16:34:42.792Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 1 of max 10
2025-10-31T16:34:42.808Z:COM:ocpp_rpc.c:1297:<- [3,"12",{}]
2025-10-31T16:34:42.824Z:COM:ocpp_rpc.c:704:-> [2,"13","StopTransaction",{"timestamp":"2025-10-31T16:34:42Z","transactionId"
2025-10-31T16:34:42.824Z:COM:ocpp_rpc.c:704::290513379,"meterStop":5540316,"idTag":"04BB29EAFD0F94","reason":"EVDisconnected
2025-10-31T16:34:42.824Z:COM:ocpp_rpc.c:704:","transactionData":[{"timestamp":"2025-10-31T16:30:50Z","sampledValue":[{"value
2025-10-31T16:34:42.824Z:COM:ocpp_rpc.c:704:":"5540.316","context":"Transaction.Begin","unit":"kWh"}]},{"timestamp":"2025-10
2025-10-31T16:34:42.824Z:COM:ocpp_rpc.c:704:-31T16:34:42Z","sampledValue":[{"value":"5540.316","context":"Transaction.End","
2025-10-31T16:34:42.824Z:COM:ocpp_rpc.c:704:unit":"kWh"}]}]}]
2025-10-31T16:34:43.242Z:COM:ocpp_rpc.c:1297:<- [3,"13",{"idTagInfo":{"status":"Invalid"}}]
2025-10-31T16:34:43.250Z:INFO:db_transaction.c:16:Updated TransactionStop for socket 1 at 0x00001905 (ts: 2025-10-31 16:34:42)
2025-10-31T16:34:43.277Z:USER:tag.c:1830:Tag 04BB29EAFD0F94 is rejected by server, white list updated
2025-10-31T16:34:43.714Z:INFO:taskMain.c:1419:Socket #1: main state: AVAILABLE, CP: 0.0/0.0, no tag
2025-10-31T16:34:49.054Z:INFO:taskMain.c:5996:Socket #1: Active current 0.0->12.8 due to current limit: Active-LoadBalancing
2025-10-31T16:34:49.125Z:INFO:taskMaster.c:4957:Socket #1: state main : CABLE_CONNECTED
2025-10-31T16:34:49.136Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_A
2025-10-31T16:34:49.144Z:INFO:taskMaster.c:4979:Socket #1: state led : CABLE_CONNECTED
2025-10-31T16:34:49.156Z:COM:ocpp_rpc.c:704:-> [2,"14","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-31T16:34:49.156Z:COM:ocpp_rpc.c:704:"Preparing"}]
2025-10-31T16:34:49.187Z:COM:ocpp_rpc.c:1297:<- [3,"14",{}]
2025-10-31T16:34:49.773Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-10-31T16:34:49.781Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-10-31T16:34:49.789Z:INFO:taskMain.c:6504:Socket #1: PP 697 Ohm (20 A)
2025-10-31T16:34:50.121Z:INFO:taskMain.c:1419:Socket #1: main state: CABLE_CONNECTED, CP: 9.3/0.9, no tag
2025-10-31T16:34:51.125Z:INFO:taskMaster.c:4957:Socket #1: state main : EV_CONNECTED_UNAUTHORIZED
2025-10-31T16:34:51.136Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-10-31T16:34:52.132Z:INFO:taskMain.c:1419:Socket #1: main state: EV_CONNECTED_UNAUTHORIZED, CP: 9.3/0.9, no tag
2025-10-31T16:34:52.476Z:INFO:taskMaster.c:6376:Socket #1: no schedule
2025-10-31T16:34:52.484Z:USER:taskMaster.c:6402:Socket #1: external current limit 16.0 A
2025-10-31T16:34:54.476Z:USER:tag.c:1623:Reader 0 Got NFC tag: 04BB29EAFD0F94
2025-10-31T16:34:54.496Z:COM:ocpp_rpc.c:704:-> [2,"15","StatusNotification",{"connectorId":0,"errorCode":"NoError","info":"I
2025-10-31T16:34:54.496Z:COM:ocpp_rpc.c:704:nfo: Charge card 04BB29EAFD0F94 detected","status":"Available"}]
2025-10-31T16:34:54.519Z:COM:ocpp_rpc.c:1297:<- [3,"15",{}]
2025-10-31T16:34:54.675Z:USER:taskMaster.c:6931:Socket #1: has reliable metervalue
2025-10-31T16:34:54.683Z:INFO:taskMaster.c:1604:1 cables attached
2025-10-31T16:34:54.726Z:INFO:taskMaster.c:4979:Socket #1: state led : AUTHORISING
2025-10-31T16:34:54.738Z:USER:tag.c:584:Tag 04BB29EAFD0F94 is not authorised by white list
2025-10-31T16:34:54.785Z:COM:ocpp_rpc.c:704:-> [2,"16","Authorize",{"idTag":"04BB29EAFD0F94"}]
2025-10-31T16:34:54.855Z:COM:ocpp_rpc.c:1297:<- [3,"16",{"idTagInfo":{"status":"Invalid"}}]
2025-10-31T16:34:54.878Z:USER:tag.c:1830:Tag 04BB29EAFD0F94 is rejected by server, white list updated
2025-10-31T16:34:54.925Z:USER:tag.c:639:Tag 04BB29EAFD0F94 is not authorised by server
2025-10-31T16:34:55.027Z:INFO:taskMaster.c:4979:Socket #1: state led : ERROR_MESSAGE
2025-10-31T16:34:55.742Z:INFO:taskMain.c:1419:Socket #1: main state: EV_CONNECTED_UNAUTHORIZED, CP: 9.3/0.9, no tag
2025-10-31T16:34:58.027Z:INFO:taskMaster.c:4979:Socket #1: state led : CABLE_CONNECTED
2025-10-31T16:35:05.527Z:USER:tag.c:1623:Reader 0 Got NFC tag: 04BB29EAFD0F94
2025-10-31T16:35:05.539Z:COM:ocpp_rpc.c:704:-> [2,"17","StatusNotification",{"connectorId":0,"errorCode":"NoError","info":"I
2025-10-31T16:35:05.539Z:COM:ocpp_rpc.c:704:nfo: Charge card 04BB29EAFD0F94 detected","status":"Available"}]
2025-10-31T16:35:05.566Z:COM:ocpp_rpc.c:1297:<- [3,"17",{}]
2025-10-31T16:35:05.726Z:USER:taskMaster.c:6931:Socket #1: has reliable metervalue
2025-10-31T16:35:05.734Z:INFO:taskMaster.c:1604:1 cables attached
2025-10-31T16:35:05.773Z:INFO:taskMaster.c:4979:Socket #1: state led : AUTHORISING
2025-10-31T16:35:05.789Z:USER:tag.c:584:Tag 04BB29EAFD0F94 is not authorised by white list
2025-10-31T16:35:05.835Z:COM:ocpp_rpc.c:704:-> [2,"18","Authorize",{"idTag":"04BB29EAFD0F94"}]
2025-10-31T16:35:05.894Z:COM:ocpp_rpc.c:1297:<- [3,"18",{"idTagInfo":{"status":"Invalid"}}]
2025-10-31T16:35:05.917Z:USER:tag.c:1830:Tag 04BB29EAFD0F94 is rejected by server, white list updated
2025-10-31T16:35:05.976Z:USER:tag.c:639:Tag 04BB29EAFD0F94 is not authorised by server
2025-10-31T16:35:06.074Z:INFO:taskMaster.c:4979:Socket #1: state led : ERROR_MESSAGE
2025-10-31T16:35:06.789Z:INFO:taskMain.c:1419:Socket #1: main state: EV_CONNECTED_UNAUTHORIZED, CP: 9.3/0.9, no tag
2025-10-31T16:35:09.125Z:INFO:taskMaster.c:4979:Socket #1: state led : CABLE_CONNECTED
2025-10-31T16:35:10.082Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T16:35:52.890Z:SECURITY:web_functionalit:63:Changed '2126_00' from 2 => 0
2025-10-31T16:35:52.898Z:WARNING:featureKeys.c:413:Resetting Plug&Charge ID to A0640314
2025-10-31T16:35:52.906Z:INFO:taskMain.c:1324:Authorisation method Plug&Charge
2025-10-31T16:35:53.632Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:35:53.667Z:INFO:taskCANopen.c:1787:Updated object 0x2063, 21 bytes
2025-10-31T16:35:53.855Z:INFO:taskCANopen.c:1787:Updated object 0x2126, 1 bytes
2025-10-31T16:36:10.898Z:SECURITY:web_functionalit:63:Changed '2126_00' from 0 => 2
2025-10-31T16:36:10.914Z:INFO:taskMain.c:1324:Authorisation method COM unit via CAN
2025-10-31T16:36:11.722Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:36:11.925Z:INFO:taskCANopen.c:1787:Updated object 0x2126, 1 bytes
2025-10-31T16:36:12.652Z:SECURITY:web_functionalit:68:Changed '2187_00' from 1761928455032 => 1761928573349
2025-10-31T16:36:12.964Z:INFO:taskCANopen.c:1787:Updated object 0x2187, 8 bytes
2025-10-31T16:36:14.730Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:36:49.113Z:INFO:taskMaster.c:4957:Socket #1: state main : CABLE_CONNECTED_TIMEOUT
2025-10-31T16:36:49.125Z:INFO:taskMaster.c:4979:Socket #1: state led : ERROR_MESSAGE
2025-10-31T16:36:49.132Z:COM:ocpp_rpc.c:704:-> [2,"19","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":
2025-10-31T16:36:49.132Z:COM:ocpp_rpc.c:704:"Finishing"}]
2025-10-31T16:36:49.167Z:COM:ocpp_rpc.c:1297:<- [3,"19",{}]
2025-10-31T16:36:49.664Z:ERROR:comFaults.c:365:Socket #1: Cable connected without tag remove cable retry [304]
2025-10-31T16:36:49.687Z:COM:ocpp_rpc.c:704:-> [2,"20","StatusNotification",{"connectorId":1,"errorCode":"NoError","info":"C
2025-10-31T16:36:49.687Z:COM:ocpp_rpc.c:704:able connected without tag remove cable retry","status":"Finishing","vendorError
2025-10-31T16:36:49.687Z:COM:ocpp_rpc.c:704:Code":"304"}]
2025-10-31T16:36:49.718Z:COM:ocpp_rpc.c:1297:<- [3,"20",{}]
2025-10-31T16:36:50.121Z:INFO:taskMain.c:1419:Socket #1: main state: CABLE_CONNECTED_TIMEOUT, CP: 9.3/0.9, no tag
2025-10-31T16:36:52.113Z:INFO:taskMaster.c:4979:Socket #1: state led : CABLE_CONNECTED
2025-10-31T16:37:19.105Z:USER:board_ng9xx.c:5068:Socket #1: unlock socket motor (forced)
2025-10-31T16:37:20.816Z:SECURITY:web_functionalit:63:Changed '3284_00' from 1 => 0
2025-10-31T16:37:21.058Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:37:21.078Z:SECURITY:web_functionalit:58:Changed '2063_00' from 'A0640314' => ''
2025-10-31T16:37:21.460Z:INFO:taskCANopen.c:1787:Updated object 0x3284, 1 bytes
2025-10-31T16:37:21.511Z:INFO:taskWifi.c:396:WiFi client left AP
2025-10-31T16:37:21.519Z:INFO:taskWifi.c:671:WiFi Module: Running --> Disabled
2025-10-31T16:37:21.527Z:INFO:taskWifi.c:678:SoftAP: Enabled --> Not Initialized
2025-10-31T16:37:21.539Z:INFO:taskWifi.c:685:STA: Not Configured --> Not Initialized
2025-10-31T16:37:22.082Z:INFO:taskCANopen.c:1787:Updated object 0x2063, 21 bytes
2025-10-31T16:37:23.074Z:SECURITY:web_functionalit:68:Changed '2187_00' from 1761928573349 => 1761928643764
2025-10-31T16:37:23.312Z:INFO:taskCANopen.c:1787:Updated object 0x2187, 8 bytes
2025-10-31T16:37:25.078Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:38:19.101Z:USER:board_ng9xx.c:5068:Socket #1: unlock socket motor (forced)
2025-10-31T16:38:31.417Z:SECURITY:httpd_login.c:155:WebClient RadomskiR connected (account: admin)
2025-10-31T16:38:33.433Z:INFO:web_functionali:159:Executing command: 'reboot'
2025-10-31T16:38:33.503Z:SECURITY:application.c:792:reset: requested, going down..
2025-10-31T16:38:45.621Z:RESET:application.c:414:==========================================
2025-10-31T16:38:45.632Z:INFO:application.c:421:build: Oct 27 2025 13:58:28
2025-10-31T16:38:45.640Z:INFO:application.c:422:version: 7.3.0-4377
2025-10-31T16:38:45.648Z:INFO:application.c:423:compiler: gcc 9.3.1
2025-10-31T16:38:45.656Z:INFO:application.c:285:fwu state inactive
2025-10-31T16:38:45.660Z:INFO:application.c:292:Bootloader version 2.2.2
2025-10-31T16:38:46.074Z:USER:taskCANopen.c:241:Persistent configuration retrieved, 284 items
2025-10-31T16:38:46.089Z:INFO:application.c:328:FLASH read protection 0xcc level 2 (permanent)
2025-10-31T16:38:46.097Z:USER:application.c:470:Using P1 port
2025-10-31T16:38:46.105Z:INFO:application.c:364:System boot #3, cause Software reset
2025-10-31T16:38:46.113Z:INFO:board_ng9xx.c:1602:Registered timeout getHardware
2025-10-31T16:38:47.824Z:INFO:bspMotors.c:616:Socket #1: Timeout while waiting for Cover motor
2025-10-31T16:38:47.882Z:INFO:board_ng9xx.c:1629:Unregistered timeout getHardware
2025-10-31T16:38:47.890Z:INFO:application.c:510:ST MCU ID......................20036419
2025-10-31T16:38:47.902Z:INFO:application.c:511:Device ID:.....................004000203531510532353530
2025-10-31T16:38:47.910Z:INFO:application.c:512:Object ID:.....................ACE0640314
2025-10-31T16:38:47.921Z:INFO:application.c:513:#Sockets.......................1
2025-10-31T16:38:47.929Z:INFO:application.c:514:MAC address eeprom.............not available
2025-10-31T16:38:47.941Z:INFO:application.c:515:Configuration eeprom...........available
2025-10-31T16:38:47.949Z:INFO:application.c:517:Flash EEPROM...................available: manuf. 0x00c2, id 0x2016 (8 MB)
2025-10-31T16:38:47.960Z:INFO:application.c:520:Temperature sensor.............available (20.0/25.2 °C)
2025-10-31T16:38:47.972Z:INFO:application.c:521:Accelerometer/tilt sensor......not available
2025-10-31T16:38:47.980Z:INFO:application.c:522:Ambient light/proximity sensor.not available
2025-10-31T16:38:47.992Z:INFO:application.c:523:Real time clock................available
2025-10-31T16:38:48.000Z:INFO:application.c:524:Mobile network modem...........Autodetect (enabled)
2025-10-31T16:38:48.011Z:INFO:application.c:525:Ethernet PHY...................available
2025-10-31T16:38:48.218Z:INFO:application.c:534:#1 Control Pilot circuit.......available (0.2/-11.7 Volts)
2025-10-31T16:38:48.230Z:INFO:application.c:535:#1 Proximity Pin circuit.......available (100000 Ohms)
2025-10-31T16:38:48.242Z:INFO:application.c:536:#1 Socket motor................available
2025-10-31T16:38:48.250Z:INFO:application.c:537:#1 Cover motor.................not available
2025-10-31T16:38:48.261Z:INFO:application.c:538:#1 Auxiliary I/O...............not available
2025-10-31T16:38:48.269Z:INFO:application.c:539:#1 Button input................not available
2025-10-31T16:38:48.281Z:INFO:application.c:540:#1 NFC reader..................not available
2025-10-31T16:38:48.289Z:INFO:application.c:541:#1 Emergency relays............available
2025-10-31T16:38:48.296Z:INFO:application.c:560:-12V power supply..............available
2025-10-31T16:38:48.308Z:INFO:application.c:561:Smart meter P1 port interface..available
2025-10-31T16:38:48.316Z:INFO:application.c:562:Smart meter Suspend input......not available
2025-10-31T16:38:48.328Z:INFO:application.c:563:Smart meter external Modbus....available
2025-10-31T16:38:48.335Z:INFO:application.c:564:Energy meter ModBus interface..available
2025-10-31T16:38:48.343Z:INFO:application.c:565:Display user interface.........available
2025-10-31T16:38:48.355Z:INFO:application.c:566:PWM Buzzer.....................not available
2025-10-31T16:38:48.363Z:INFO:application.c:569:Auxiliary Board................supported
2025-10-31T16:38:48.375Z:INFO:application.c:570:Auxiliary Board revision.......D
2025-10-31T16:38:48.382Z:INFO:application.c:572:Powerboard revision/assy.......GUNKNOWN (32.0A)
2025-10-31T16:38:48.390Z:INFO:application.c:573:Controllerboard revision/assy..L7
2025-10-31T16:38:48.402Z:INFO:application.c:574:Powerboard relay type..........LATCHING_REVERSED
2025-10-31T16:38:48.410Z:INFO:application.c:592:Operational time ..............0D 00H
2025-10-31T16:38:48.425Z:INFO:db_common.c:147:Initializing all databases..
2025-10-31T16:38:48.851Z:INFO:db_base.c:1325:Initialized Transaction db (firstItem=0x00000000, lastItem=0x00001905)
2025-10-31T16:38:48.867Z:INFO:db_base.c:1325:Initialized LocalList db (firstItem=0x00000000, lastItem=0x00000000)
2025-10-31T16:38:48.882Z:INFO:db_base.c:1325:Initialized WhiteList db (firstItem=0x00000000, lastItem=0x00000041)
2025-10-31T16:38:48.898Z:INFO:db_base.c:1325:Initialized ChargingProfile db (firstItem=0x00000000, lastItem=0x000001b1)
2025-10-31T16:38:48.929Z:INFO:db_chargingprofi:75:Defragmented (#0/0, 18ms)
2025-10-31T16:38:48.937Z:INFO:db_chargingprofi:19:Max 45 charging profiles of 100 periods
2025-10-31T16:38:48.945Z:INFO:db_base.c:1325:Initialized Domain db (firstItem=0x00000000, lastItem=0x00000070)
2025-10-31T16:38:48.964Z:INFO:board_ng9xx.c:1602:Registered timeout BootNotification
2025-10-31T16:38:49.000Z:INFO:featureKeys.c:78:Unlocked Features: SCN,RFID-reader,4G (80010101)
2025-10-31T16:38:49.011Z:INFO:taskMain.c:599:Socket #1: Authorisation method COM unit via CAN
2025-10-31T16:38:49.019Z:INFO:taskMain.c:602:Socket #1: SocketType Mennekes
2025-10-31T16:38:49.027Z:INFO:taskMain.c:606:Socket #1: startup delay 5 s
2025-10-31T16:38:49.039Z:INFO:board_ng9xx.c:1602:Registered timeout NUVVE
2025-10-31T16:38:49.046Z:INFO:board_ng9xx.c:1602:Registered timeout NUVVE
2025-10-31T16:38:49.066Z:USER:EVsimulator.c:210:EV simulator initialised
2025-10-31T16:38:49.070Z:USER:taskMaster.c:1054:local Smart Charging Mode
2025-10-31T16:38:49.285Z:INFO:bspEthernet.c:165:Ethernet PHY LAN8710@0x00
2025-10-31T16:38:49.300Z:USER:bspEthernet.c:238:ETH PHY OK
2025-10-31T16:38:49.308Z:INFO:bspEthernet.c:217:MACAddress: [26:64:44:07:10:35]
2025-10-31T16:38:49.320Z:INFO:taskMeter.c:318:Starting smartmeter with protocol P1
2025-10-31T16:38:49.328Z:INFO:scn.c:686:Loadbalancing: Feature enabled
2025-10-31T16:38:49.335Z:INFO:scn.c:687:SCN: Feature enabled [Off]
2025-10-31T16:38:49.343Z:WARNING:scn_communicatio:75:SCN: Not enough sockets for an SCN!
2025-10-31T16:38:49.355Z:INFO:modem.c:1124:Modem state Idle->InitHw
2025-10-31T16:38:49.371Z:INFO:taskMain.c:1294:contactorstabletime : 50
2025-10-31T16:38:49.378Z:INFO:taskMain.c:1295:HFContactorSwitchTime : 60
2025-10-31T16:38:49.394Z:INFO:taskLeds.c:226:LED UI initialized OK
2025-10-31T16:38:49.402Z:INFO:taskMain.c:6180:Socket #1: DSC initialised
2025-10-31T16:38:49.410Z:INFO:station.c:184:Active station current set to 16.0A max
2025-10-31T16:38:49.425Z:INFO:taskMain.c:6504:Socket #1: PP 34464 Ohm (0 A)
2025-10-31T16:38:49.433Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.0% (6.0 A)
2025-10-31T16:38:49.441Z:INFO:comConnect.c:295:Connectivity state: STARTUP
2025-10-31T16:38:49.453Z:USER:application.c:718:Initialisation done
2025-10-31T16:38:49.472Z:ERROR:bspEthernet.c:353:Link lost during autonegotiate transaction
2025-10-31T16:38:49.484Z:INFO:taskTCPIP.c:958:Network Cable is now connected
2025-10-31T16:38:49.492Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-10-31T16:38:49.601Z:INFO:taskTCPIP.c:966:Network Cable is unplugged
2025-10-31T16:38:49.996Z:INFO:taskModbus.c:4526:Address #1: modbus meter vendor : ALF
2025-10-31T16:38:50.003Z:INFO:taskModbus.c:4527:Address #1: modbus meter model : D3001
2025-10-31T16:38:50.015Z:INFO:taskModbus.c:4528:Address #1: modbus meter revision : V1.03
2025-10-31T16:38:50.023Z:INFO:taskModbus.c:4529:Address #1: modbus meter meterNumber : 22391493
2025-10-31T16:38:50.035Z:USER:taskModbus.c:936:Socket_1 Meter(1): meter type DZG_REALLIN found
2025-10-31T16:38:50.359Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:38:50.367Z:INFO:taskCANopen.c:1212:Persistent memory not cached
2025-10-31T16:38:50.375Z:INFO:taskNFCreader.c:579:Port #0 switch NFC power on
2025-10-31T16:38:50.449Z:INFO:taskMain.c:1419:Socket #1: main state: BOOTING, CP: 0.0/0.0, no tag
2025-10-31T16:38:50.472Z:INFO:taskCANopen.c:2020:CanOpen EEPROM cache size: 284, got 284 objects <284,0>
2025-10-31T16:38:50.500Z:INFO:taskCANopen.c:1787:Updated object 0x2056, 4 bytes
2025-10-31T16:38:50.531Z:USER:taskModbus.c:1107:Socket_1 Meter(1): first meter update, Multiple phase installation
2025-10-31T16:38:51.261Z:USER:bspEthernet.c:342:Mode: 100Mb/s full duplex
2025-10-31T16:38:51.269Z:INFO:taskTCPIP.c:958:Network Cable is now connected
2025-10-31T16:38:51.585Z:USER:taskMaster.c:1329:Node #1, version 7.3.0-4377
2025-10-31T16:38:51.824Z:INFO:taskTCPIP.c:1617: IP address assigned by DHCP
2025-10-31T16:38:51.832Z:INFO:taskTCPIP.c:1645:Network interface is up
2025-10-31T16:38:51.839Z:INFO:taskTCPIP.c:1654: IP : 192.168.178.184
2025-10-31T16:38:51.847Z:INFO:taskTCPIP.c:1655: Netmask : 255.255.255.0
2025-10-31T16:38:51.855Z:INFO:taskTCPIP.c:1656: Gateway : 192.168.178.1
2025-10-31T16:38:51.863Z:INFO:taskTCPIP.c:1657: DNS1 : 192.168.178.1
2025-10-31T16:38:51.871Z:INFO:taskTCPIP.c:1658: DNS2 : 208.67.220.220
2025-10-31T16:38:51.878Z:INFO:taskTCPIP.c:512:Starting mDNS on interface al
2025-10-31T16:38:51.886Z:INFO:taskTCPIP.c:512:Starting Webserver on interface al
2025-10-31T16:38:51.894Z:INFO:taskTCPIP.c:512:Starting Modbus on interface al
2025-10-31T16:38:51.902Z:INFO:taskTCPIP.c:512:Starting P1 on interface al
2025-10-31T16:38:51.914Z:INFO:taskTCPIP.c:512:Starting SCN on interface al
2025-10-31T16:38:51.921Z:INFO:taskTCPIP.c:413:default network set to 'al'
2025-10-31T16:38:51.933Z:INFO:taskWebServer.c:238:WebServer state WAIT_FOR_NETWORK -> SETUP
2025-10-31T16:38:51.968Z:USER:taskWebServer.c:360:WebServer started on port 443
2025-10-31T16:38:51.976Z:INFO:taskWebServer.c:238:WebServer state SETUP -> AVAILABLE
2025-10-31T16:38:54.410Z:INFO:comConnect.c:295:Connectivity state: INITIALISING
2025-10-31T16:38:54.417Z:INFO:taskNFCreader.c:115:Port #0 version response: "ICU NFC 243B (v3) v3.1-531"
2025-10-31T16:38:54.429Z:USER:taskMaster.c:1359:NFC version: ICU NFC 243B (v3) v3.1-531
2025-10-31T16:38:54.437Z:INFO:comConnect.c:295:Connectivity state: STANDALONE
2025-10-31T16:38:54.578Z:INFO:taskNFCreader.c:131:Port #0 ICU NFC reader BL3 v3.1, 1 LEDs
2025-10-31T16:38:54.589Z:INFO:taskNFCreader.c:132:Port #0 reader model: Giro-e
2025-10-31T16:38:56.667Z:INFO:modem.c:1124:Modem state InitHw->InitModem
2025-10-31T16:38:56.675Z:INFO:modem.c:1296:Reset delay 2s
2025-10-31T16:38:57.441Z:INFO:taskMaster.c:1137:Socket #1 has a Modbus meter
2025-10-31T16:38:57.449Z:INFO:updatefirmware.c:52:BL FWU_STATUS_INACTIVE -> int IDLE
2025-10-31T16:38:57.457Z:INFO:taskMain.c:1678:Socket #1: recovered WAIT_FOR_DISCONNECT
2025-10-31T16:38:57.468Z:USER:taskMaster.c:1164:1 NFC readers found
2025-10-31T16:38:57.492Z:INFO:taskMaster.c:1575:Socket #1: no open transaction
2025-10-31T16:38:57.515Z:INFO:smartMeter.c:80:Set phases: (L1, L2, L3)->(L1, L2, L3)
2025-10-31T16:38:57.523Z:INFO:active_lb.c:308:SMt:(0.0 0.0 0.0)A Free:(16.0 16.0 16.0)A ALB:(0.0 0.0 0.0)A
2025-10-31T16:38:57.535Z:INFO:taskMaster.c:4957:Socket #1: state main : WAIT_FOR_DISCONNECT
2025-10-31T16:38:57.542Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-10-31T16:38:57.554Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-10-31T16:38:57.562Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_DISCONNECT
2025-10-31T16:38:57.621Z:INFO:taskMaster.c:6376:Socket #1: no schedule
2025-10-31T16:38:57.628Z:USER:taskMaster.c:6402:Socket #1: external current limit 16.0 A
2025-10-31T16:38:57.640Z:INFO:station.c:97:station external max - new value: 99.9A
2025-10-31T16:38:57.648Z:INFO:comFaults.c:482:Reset fault status
2025-10-31T16:38:57.656Z:USER:taskMaster.c:1359:NFC version: ICU NFC 243B (v3) v3.1-531
2025-10-31T16:38:58.500Z:INFO:taskMain.c:1419:Socket #1: main state: WAIT_FOR_DISCONNECT, CP: 0.0/0.0, no tag
2025-10-31T16:39:00.871Z:USER:modem.c:3611:Modem type: Quectel BG95-M3
2025-10-31T16:39:00.886Z:INFO:modem.c:3090:Check if modem responds
2025-10-31T16:39:00.925Z:INFO:modem.c:2977:Set flow control (on)
2025-10-31T16:39:01.097Z:INFO:modem.c:3130:Set type of logging
2025-10-31T16:39:05.078Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:39:05.507Z:SECURITY:httpd_login.c:155:WebClient RadomskiR connected (account: admin)
2025-10-31T16:39:07.531Z:INFO:taskMaster.c:4957:Socket #1: state main : AVAILABLE
2025-10-31T16:39:07.550Z:INFO:taskMain.c:6440:Socket #1: active tag cleared
2025-10-31T16:39:07.593Z:INFO:taskMaster.c:4979:Socket #1: state led : AVAILABLE
2025-10-31T16:39:07.683Z:INFO:comFaults.c:1075:#phases: socket #1 ''->'L1L2L3'
2025-10-31T16:39:08.519Z:INFO:taskMain.c:1419:Socket #1: main state: AVAILABLE, CP: 0.0/0.0, no tag
2025-10-31T16:39:19.578Z:INFO:modem.c:2525:Check PIN
2025-10-31T16:39:23.351Z:WARNING:modem.c:2562:SIM error
2025-10-31T16:39:25.933Z:INFO:taskWifi.c:671:WiFi Module: Not Initialized --> Disabled
2025-10-31T16:39:27.230Z:WARNING:modem.c:2562:SIM error
2025-10-31T16:39:31.105Z:WARNING:modem.c:2562:SIM error
2025-10-31T16:39:33.156Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x50)
2025-10-31T16:39:33.164Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-31T16:39:33.273Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-31T16:39:34.984Z:WARNING:modem.c:2562:SIM error
2025-10-31T16:39:35.089Z:INFO:modem.c:2572:Check PIN failed
2025-10-31T16:39:35.351Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:39:35.417Z:SECURITY:taskWebClient.c:446:Received unauthorized request, so removing client
2025-10-31T16:39:35.429Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-31T16:39:35.480Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-31T16:39:37.234Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:39:37.898Z:SECURITY:httpd_login.c:155:WebClient RadomskiR connected (account: admin)
2025-10-31T16:39:49.855Z:INFO:modem.c:3291:Get other info
2025-10-31T16:40:22.960Z:WARNING:modem.c:2725:AT+CSQ, invalid value(99)
2025-10-31T16:40:32.230Z:INFO:taskMain.c:5996:Socket #1: Active current 0.0->12.8 due to current limit: Active-LoadBalancing
2025-10-31T16:40:32.273Z:INFO:taskMaster.c:4957:Socket #1: state main : CABLE_CONNECTED
2025-10-31T16:40:32.285Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_A
2025-10-31T16:40:32.292Z:INFO:taskMaster.c:4979:Socket #1: state led : CABLE_CONNECTED
2025-10-31T16:40:32.339Z:INFO:taskMain.c:6494:Socket #1: CPhigh 12.3 V
2025-10-31T16:40:32.347Z:INFO:taskMain.c:6499:Socket #1: CPlow 12.4 V
2025-10-31T16:40:32.355Z:INFO:taskMain.c:6504:Socket #1: PP 698 Ohm (20 A)
2025-10-31T16:40:32.363Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.3% (12.8 A)
2025-10-31T16:40:33.308Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-10-31T16:40:33.316Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-10-31T16:40:33.324Z:INFO:taskMain.c:1419:Socket #1: main state: CABLE_CONNECTED, CP: 9.3/0.9, no tag
2025-10-31T16:40:34.324Z:INFO:taskMaster.c:4957:Socket #1: state main : EV_CONNECTED_UNAUTHORIZED
2025-10-31T16:40:34.335Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-10-31T16:40:35.308Z:INFO:taskMain.c:1419:Socket #1: main state: EV_CONNECTED_UNAUTHORIZED, CP: 9.3/0.9, no tag
2025-10-31T16:40:37.472Z:USER:tag.c:1623:Reader 0 Got NFC tag: 04BB29EAFD0F94
2025-10-31T16:40:37.671Z:USER:taskMaster.c:6931:Socket #1: has reliable metervalue
2025-10-31T16:40:37.683Z:INFO:taskMaster.c:1604:1 cables attached
2025-10-31T16:40:37.722Z:INFO:taskMaster.c:4979:Socket #1: state led : AUTHORISING
2025-10-31T16:40:37.738Z:USER:tag.c:584:Tag 04BB29EAFD0F94 is authorised by white list
2025-10-31T16:40:37.824Z:USER:taskMaster.c:1914:Multiple cables attached, prioritizing socket #1
2025-10-31T16:40:37.871Z:USER:board_ng9xx.c:5068:Socket #1: lock socket motor
2025-10-31T16:40:37.878Z:INFO:taskMaster.c:4957:Socket #1: state main : EV_CONNECTED_AUTHORIZED
2025-10-31T16:40:38.691Z:INFO:taskMaster.c:7497:New charging session started, metervalue=5540316.000
2025-10-31T16:40:38.707Z:INFO:db_transaction.c:16:Added TransactionStart for socket 1 at 0x00001936 (ts: 2025-10-31 16:40:37)
2025-10-31T16:40:38.726Z:INFO:taskMaster.c:4979:Socket #1: state led : EV_CONNECTED
2025-10-31T16:40:38.738Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T16:40:38.796Z:INFO:taskMaster.c:6353:Socket #1: external current limit 15.9 A until 2025-10-31T23:00:00Z
2025-10-31T16:40:38.808Z:USER:taskMaster.c:6402:Socket #1: external current limit 15.9 A
2025-10-31T16:40:38.878Z:INFO:taskMain.c:1417:Socket #1: main state: EV_CONNECTED_AUTHORIZED, CP: 9.3/9.3, tag: 04BB29EAFD0F94
2025-10-31T16:40:38.968Z:INFO:taskMain.c:938:Socket #1: charging session status set active
2025-10-31T16:40:38.980Z:INFO:taskMaster.c:4957:Socket #1: state main : WAIT_FOR_START_METERVALUE
2025-10-31T16:40:38.988Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_PREPARING
2025-10-31T16:40:40.078Z:INFO:taskMain.c:1417:Socket #1: main state: WAIT_FOR_START_METERVALUE, CP: 9.3/9.3, tag: 04BB29EAFD0F
2025-10-31T16:40:40.078Z:INFO:taskMain.c:1417:94
2025-10-31T16:40:42.023Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-10-31T16:40:42.031Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-10-31T16:40:42.074Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-10-31T16:40:42.097Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-10-31T16:40:43.050Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-10-31T16:40:43.222Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-10-31T16:40:43.234Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-10-31T16:40:43.242Z:USER:taskMaster.c:6684:Socket #1: L1N=230.2V L2N=230.4V L3N=231.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T16:40:43.253Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T16:40:43.265Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-10-31T16:40:43.273Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-10-31T16:40:43.281Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-10-31T16:40:44.058Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-10-31T16:40:44.218Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-10-31T16:40:46.546Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.9 due to current limit: Active-LoadBalancing
2025-10-31T16:40:47.250Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-10-31T16:40:48.824Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-31T16:40:48.835Z:INFO:db_chargingprofi:26: socket 0
2025-10-31T16:40:48.843Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-31T16:40:48.851Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-31T16:40:48.859Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-31T16:40:48.867Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-31T16:40:48.878Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-31T16:40:48.886Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-31T16:40:48.894Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-31T16:40:48.902Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-31T16:40:48.910Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-31T16:40:48.921Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-31T16:40:48.929Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-31T16:40:48.937Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-31T16:40:48.949Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-31T16:40:48.957Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-31T16:40:48.968Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-31T16:40:48.976Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-31T16:40:48.984Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-31T16:40:48.992Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-31T16:40:49.000Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-31T16:40:49.007Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-31T16:40:49.015Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-31T16:40:49.121Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-10-31T16:40:51.546Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->15.9 due to current limit: ChargingProfile
2025-10-31T16:40:52.296Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-10-31T16:40:54.949Z:INFO:modem.c:3313:Signal strength : Unknown
2025-10-31T16:40:54.957Z:INFO:modem.c:3315:Radio Access Tech : 4G
2025-10-31T16:40:54.964Z:INFO:modem.c:3316:Registration mode : Disabled
2025-10-31T16:40:54.976Z:INFO:modem.c:3317:Registration status: Not registered
2025-10-31T16:40:54.988Z:INFO:modem.c:3318:Operator : 0
2025-10-31T16:40:54.992Z:INFO:modem.c:3319:Manufacturer : Quectel
2025-10-31T16:40:55.003Z:INFO:modem.c:3320:Modem module : BG95-M3
2025-10-31T16:40:55.011Z:INFO:modem.c:3321:Modem revision : BG95M3LAR02A03_01.012.01.012
2025-10-31T16:40:55.019Z:INFO:modem.c:3322:Modem IMEI : 864145067568848
2025-10-31T16:40:55.027Z:INFO:modem.c:3323:SIM IMSI :
2025-10-31T16:40:55.035Z:INFO:modem.c:3324:SIM ICCID :
2025-10-31T16:40:55.042Z:INFO:modem.c:3325:Modem supports 2G : yes
2025-10-31T16:40:55.050Z:INFO:modem.c:3326:Modem supports 3G : no
2025-10-31T16:40:55.058Z:INFO:modem.c:3327:Modem supports 4G : yes
2025-10-31T16:40:55.109Z:INFO:modem.c:3334:Cellinfo : "SEARCH"
2025-10-31T16:40:55.117Z:ERROR:modem.c:3364:Setup modem Failed
2025-10-31T16:40:55.121Z:INFO:modem.c:1124:Modem state InitModem->Stopping
2025-10-31T16:41:03.644Z:INFO:modem.c:1124:Modem state Stopping->Idle
2025-10-31T16:41:13.074Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->14.8 due to current limit: Active-LoadBalancing
2025-10-31T16:41:13.089Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->24.6)
2025-10-31T16:41:13.121Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-10-31T16:41:13.269Z:USER:taskMaster.c:6684:Socket #1: L1N=228.5V L2N=230.9V L3N=229.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T16:41:13.281Z:USER:taskMaster.c:6720:Socket #1: I1=14.4A I2=14.0A I3=15.4A P=10.7kW Idc=0.7mA
2025-10-31T16:41:13.503Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.6% (14.8 A)
2025-10-31T16:41:25.074Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.9 due to current limit: ChargingProfile
2025-10-31T16:41:25.117Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-10-31T16:41:25.625Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-10-31T16:41:30.605Z:SECURITY:web_functionali:105:Webserver logout client 1
2025-10-31T16:41:30.621Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-31T16:41:30.730Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-31T16:41:35.089Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:41:35.382Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-31T16:41:36.656Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x0)
2025-10-31T16:41:36.664Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-31T16:41:36.703Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-31T16:41:43.203Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-10-31T16:41:43.265Z:USER:taskMaster.c:6684:Socket #1: L1N=228.3V L2N=228.9V L3N=229.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T16:41:43.277Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.6A I3=15.6A P=10.7kW Idc=0.7mA
2025-10-31T16:41:43.730Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T16:41:44.031Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-31T16:41:44.433Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-31T16:41:44.523Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-10-31T16:41:49.070Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.7 due to current limit: Active-LoadBalancing
2025-10-31T16:41:49.085Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->26.1)
2025-10-31T16:41:49.121Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-10-31T16:41:54.140Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x0)
2025-10-31T16:41:54.148Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-31T16:41:54.218Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-31T16:42:01.070Z:INFO:taskMain.c:5996:Socket #1: Active current 15.7->14.3 due to current limit: Active-LoadBalancing
2025-10-31T16:42:01.082Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.1->23.8)
2025-10-31T16:42:01.980Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.8% (14.3 A)
2025-10-31T16:42:13.070Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->12.9 due to current limit: Active-LoadBalancing
2025-10-31T16:42:13.082Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->21.5)
2025-10-31T16:42:13.093Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.5% (12.9 A)
2025-10-31T16:42:13.265Z:USER:taskMaster.c:6684:Socket #1: L1N=228.5V L2N=229.3V L3N=229.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T16:42:13.277Z:USER:taskMaster.c:6720:Socket #1: I1=13.8A I2=13.9A I3=13.9A P=9.5kW Idc=0.7mA
2025-10-31T16:42:19.867Z:INFO:taskLeds.c:338:Brightness set to 8%
2025-10-31T16:42:25.066Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.4 due to current limit: Active-LoadBalancing
2025-10-31T16:42:25.082Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.5->20.6)
2025-10-31T16:42:25.207Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-10-31T16:42:37.066Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.3 due to current limit: Active-LoadBalancing
2025-10-31T16:42:37.078Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.6->20.4)
2025-10-31T16:42:43.261Z:USER:taskMaster.c:6684:Socket #1: L1N=229.3V L2N=229.0V L3N=229.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T16:42:43.273Z:USER:taskMaster.c:6720:Socket #1: I1=11.8A I2=11.9A I3=11.8A P=8.1kW Idc=0.7mA
2025-10-31T16:42:49.066Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.1 due to current limit: Active-LoadBalancing
2025-10-31T16:42:49.078Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.4->20.1)
2025-10-31T16:43:01.066Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->11.9 due to current limit: Active-LoadBalancing
2025-10-31T16:43:01.078Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.1->19.9)
2025-10-31T16:43:13.062Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->12.2 due to current limit: Active-LoadBalancing
2025-10-31T16:43:13.257Z:USER:taskMaster.c:6684:Socket #1: L1N=229.1V L2N=229.8V L3N=229.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T16:43:13.269Z:USER:taskMaster.c:6720:Socket #1: I1=11.5A I2=11.6A I3=11.6A P=8.0kW Idc=0.7mA
2025-10-31T16:43:13.707Z:INFO:EVCapabilities.c:24:Socket #1 EV: #phases supported: 3
2025-10-31T16:43:25.062Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-10-31T16:43:37.062Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-10-31T16:43:43.253Z:USER:taskMaster.c:6684:Socket #1: L1N=229.1V L2N=229.8V L3N=230.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T16:43:43.265Z:USER:taskMaster.c:6720:Socket #1: I1=12.3A I2=12.4A I3=12.4A P=8.5kW Idc=0.7mA
2025-10-31T16:43:49.058Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->13.0 due to current limit: Active-LoadBalancing
2025-10-31T16:44:01.058Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.2 due to current limit: Active-LoadBalancing
2025-10-31T16:44:13.058Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.1 due to current limit: Active-LoadBalancing
2025-10-31T16:44:13.070Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.0->21.8)
2025-10-31T16:44:13.250Z:USER:taskMaster.c:6684:Socket #1: L1N=229.8V L2N=229.7V L3N=229.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T16:44:13.261Z:USER:taskMaster.c:6720:Socket #1: I1=12.8A I2=12.9A I3=12.8A P=8.8kW Idc=0.7mA
2025-10-31T16:44:25.054Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.9 due to current limit: Active-LoadBalancing
2025-10-31T16:44:25.066Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.8->21.5)
2025-10-31T16:44:37.054Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.8 due to current limit: Active-LoadBalancing
2025-10-31T16:44:37.066Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.5->21.3)
2025-10-31T16:44:43.246Z:USER:taskMaster.c:6684:Socket #1: L1N=229.5V L2N=230.2V L3N=229.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T16:44:43.261Z:USER:taskMaster.c:6720:Socket #1: I1=12.3A I2=12.4A I3=12.3A P=8.5kW Idc=0.7mA
2025-10-31T16:44:49.054Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.6 due to current limit: Active-LoadBalancing
2025-10-31T16:44:49.066Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.3->21.0)
2025-10-31T16:45:01.050Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.5 due to current limit: Active-LoadBalancing
2025-10-31T16:45:01.066Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.0->20.8)
2025-10-31T16:45:09.832Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 1 of max 10
2025-10-31T16:45:13.050Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-10-31T16:45:13.062Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.8->20.5)
2025-10-31T16:45:13.246Z:USER:taskMaster.c:6684:Socket #1: L1N=228.5V L2N=229.4V L3N=229.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T16:45:13.257Z:USER:taskMaster.c:6720:Socket #1: I1=12.0A I2=12.1A I3=12.0A P=8.3kW Idc=0.7mA
2025-10-31T16:45:25.050Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.6 due to current limit: Active-LoadBalancing
2025-10-31T16:45:37.046Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.9 due to current limit: Active-LoadBalancing
2025-10-31T16:45:43.242Z:USER:taskMaster.c:6684:Socket #1: L1N=229.1V L2N=229.0V L3N=229.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T16:45:43.253Z:USER:taskMaster.c:6720:Socket #1: I1=12.5A I2=12.5A I3=12.5A P=8.6kW Idc=0.7mA
2025-10-31T16:45:43.265Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-10-31T16:45:49.046Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.1 due to current limit: Active-LoadBalancing
2025-10-31T16:46:01.046Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.0 due to current limit: Active-LoadBalancing
2025-10-31T16:46:01.058Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.9->21.6)
2025-10-31T16:46:12.527Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:46:12.828Z:INFO:taskCANopen.c:1787:Updated object 0x2249, 9 bytes
2025-10-31T16:46:13.042Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.8 due to current limit: Active-LoadBalancing
2025-10-31T16:46:13.058Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.6->21.3)
2025-10-31T16:46:25.042Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.7 due to current limit: Active-LoadBalancing
2025-10-31T16:46:25.054Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.3->21.1)
2025-10-31T16:46:37.042Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.5 due to current limit: Active-LoadBalancing
2025-10-31T16:46:37.054Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.1->20.8)
2025-10-31T16:46:49.039Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.4 due to current limit: Active-LoadBalancing
2025-10-31T16:46:49.054Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.8->20.6)
2025-10-31T16:47:01.039Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T16:47:13.039Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.9 due to current limit: Active-LoadBalancing
2025-10-31T16:47:25.035Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.7 due to current limit: Active-LoadBalancing
2025-10-31T16:47:25.050Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.4->21.2)
2025-10-31T16:47:37.035Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.6 due to current limit: Active-LoadBalancing
2025-10-31T16:47:37.046Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.2->20.9)
2025-10-31T16:47:49.035Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-10-31T16:47:49.046Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.9->20.7)
2025-10-31T16:48:01.031Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.3 due to current limit: Active-LoadBalancing
2025-10-31T16:48:01.046Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.7->20.5)
2025-10-31T16:48:13.031Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-10-31T16:48:13.042Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.5->20.2)
2025-10-31T16:48:25.031Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.4 due to current limit: Active-LoadBalancing
2025-10-31T16:48:37.027Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.7 due to current limit: Active-LoadBalancing
2025-10-31T16:48:49.027Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.9 due to current limit: Active-LoadBalancing
2025-10-31T16:48:57.472Z:INFO:active_lb.c:308:SMt:(13.0 16.0 13.0)A Free:(3.0 0.0 3.0)A ALB:(15.7 12.9 14.9)A
2025-10-31T16:49:01.027Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.8 due to current limit: Active-LoadBalancing
2025-10-31T16:49:01.039Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.5->21.3)
2025-10-31T16:49:13.023Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.6 due to current limit: Active-LoadBalancing
2025-10-31T16:49:13.039Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.3->21.0)
2025-10-31T16:49:25.023Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.5 due to current limit: Active-LoadBalancing
2025-10-31T16:49:25.035Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.0->20.8)
2025-10-31T16:49:32.503Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:49:32.804Z:INFO:taskCANopen.c:1787:Updated object 0x2249, 9 bytes
2025-10-31T16:49:37.023Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-10-31T16:49:37.035Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.8->20.5)
2025-10-31T16:49:49.019Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-10-31T16:49:49.035Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.5->20.3)
2025-10-31T16:50:01.019Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.4 due to current limit: Active-LoadBalancing
2025-10-31T16:50:13.019Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.7 due to current limit: Active-LoadBalancing
2025-10-31T16:50:25.019Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->13.0 due to current limit: Active-LoadBalancing
2025-10-31T16:50:37.015Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.8 due to current limit: Active-LoadBalancing
2025-10-31T16:50:37.027Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.5->21.3)
2025-10-31T16:50:49.015Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.7 due to current limit: Active-LoadBalancing
2025-10-31T16:50:49.027Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.3->21.0)
2025-10-31T16:51:01.015Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.5 due to current limit: Active-LoadBalancing
2025-10-31T16:51:01.027Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.0->20.8)
2025-10-31T16:51:13.011Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-10-31T16:51:13.023Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.8->20.5)
2025-10-31T16:51:25.011Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-10-31T16:51:25.023Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.5->20.3)
2025-10-31T16:51:35.660Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 2 of max 10
2025-10-31T16:51:37.011Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.4 due to current limit: Active-LoadBalancing
2025-10-31T16:51:49.007Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.7 due to current limit: Active-LoadBalancing
2025-10-31T16:52:01.007Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.9 due to current limit: Active-LoadBalancing
2025-10-31T16:52:13.007Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.8 due to current limit: Active-LoadBalancing
2025-10-31T16:52:13.019Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.5->21.3)
2025-10-31T16:52:22.332Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:52:22.625Z:INFO:taskCANopen.c:1787:Updated object 0x2249, 9 bytes
2025-10-31T16:52:25.003Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.6 due to current limit: Active-LoadBalancing
2025-10-31T16:52:25.019Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.3->21.0)
2025-10-31T16:52:37.003Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.5 due to current limit: Active-LoadBalancing
2025-10-31T16:52:37.015Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.0->20.8)
2025-10-31T16:52:49.003Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-10-31T16:52:49.015Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.8->20.5)
2025-10-31T16:53:01.000Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-10-31T16:53:01.015Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.5->20.3)
2025-10-31T16:53:13.000Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.4 due to current limit: Active-LoadBalancing
2025-10-31T16:53:25.000Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.7 due to current limit: Active-LoadBalancing
2025-10-31T16:53:36.996Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.9 due to current limit: Active-LoadBalancing
2025-10-31T16:53:41.589Z:USER:taskMaster.c:6582:Temperature: 26.5 C
2025-10-31T16:53:48.996Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.2 due to current limit: Active-LoadBalancing
2025-10-31T16:54:00.996Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.5 due to current limit: Active-LoadBalancing
2025-10-31T16:54:12.992Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-10-31T16:54:13.007Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.4->22.2)
2025-10-31T16:54:24.992Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-10-31T16:54:25.003Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.2->21.9)
2025-10-31T16:54:36.992Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.0 due to current limit: Active-LoadBalancing
2025-10-31T16:54:37.003Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.9->21.7)
2025-10-31T16:54:48.988Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.9 due to current limit: Active-LoadBalancing
2025-10-31T16:54:49.003Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.7->21.5)
2025-10-31T16:55:00.988Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.8 due to current limit: Active-LoadBalancing
2025-10-31T16:55:01.000Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.5->21.2)
2025-10-31T16:55:12.988Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.6 due to current limit: Active-LoadBalancing
2025-10-31T16:55:13.000Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.2->21.0)
2025-10-31T16:55:24.984Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.5 due to current limit: Active-LoadBalancing
2025-10-31T16:55:25.000Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.0->20.8)
2025-10-31T16:55:36.984Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-10-31T16:55:36.996Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.8->20.5)
2025-10-31T16:55:38.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T16:55:48.984Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-10-31T16:55:48.996Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.5->20.3)
2025-10-31T16:56:00.980Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.4 due to current limit: Active-LoadBalancing
2025-10-31T16:56:12.980Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.7 due to current limit: Active-LoadBalancing
2025-10-31T16:56:24.980Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.9 due to current limit: Active-LoadBalancing
2025-10-31T16:56:36.976Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.8 due to current limit: Active-LoadBalancing
2025-10-31T16:56:36.992Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.5->21.3)
2025-10-31T16:56:48.976Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.6 due to current limit: Active-LoadBalancing
2025-10-31T16:56:48.988Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.3->21.0)
2025-10-31T16:57:00.976Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.5 due to current limit: Active-LoadBalancing
2025-10-31T16:57:00.988Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.0->20.8)
2025-10-31T16:57:02.707Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T16:57:03.007Z:INFO:taskCANopen.c:1787:Updated object 0x2249, 9 bytes
2025-10-31T16:57:12.972Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-10-31T16:57:12.988Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.8->20.5)
2025-10-31T16:57:24.972Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.6 due to current limit: Active-LoadBalancing
2025-10-31T16:57:36.972Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.9 due to current limit: Active-LoadBalancing
2025-10-31T16:57:48.972Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.1 due to current limit: Active-LoadBalancing
2025-10-31T16:58:00.968Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.4 due to current limit: Active-LoadBalancing
2025-10-31T16:58:01.488Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 3 of max 10
2025-10-31T16:58:12.968Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-10-31T16:58:12.980Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.3->22.0)
2025-10-31T16:58:24.968Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.1 due to current limit: Active-LoadBalancing
2025-10-31T16:58:24.980Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.0->21.8)
2025-10-31T16:58:36.964Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.9 due to current limit: Active-LoadBalancing
2025-10-31T16:58:36.976Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.8->21.5)
2025-10-31T16:58:48.964Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.8 due to current limit: Active-LoadBalancing
2025-10-31T16:58:48.976Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.5->21.3)
2025-10-31T16:58:57.406Z:INFO:active_lb.c:308:SMt:(13.0 15.0 14.0)A Free:(3.0 1.0 2.0)A ALB:(15.7 12.8 14.7)A
2025-10-31T16:59:00.964Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->13.0 due to current limit: Active-LoadBalancing
2025-10-31T16:59:12.960Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.3 due to current limit: Active-LoadBalancing
2025-10-31T16:59:24.960Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.5 due to current limit: Active-LoadBalancing
2025-10-31T16:59:36.960Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.4 due to current limit: Active-LoadBalancing
2025-10-31T16:59:36.972Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.5->22.3)
2025-10-31T16:59:48.957Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-10-31T16:59:48.972Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.3->22.0)
2025-10-31T17:00:00.957Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:00:00.968Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.0->21.8)
2025-10-31T17:00:12.957Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:00:12.968Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.8->21.5)
2025-10-31T17:00:24.953Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:00:36.953Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.5 due to current limit: Active-LoadBalancing
2025-10-31T17:00:43.144Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=232.4V L3N=231.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T17:00:43.160Z:USER:taskMaster.c:6720:Socket #1: I1=13.0A I2=13.1A I3=13.1A P=9.1kW Idc=0.7mA
2025-10-31T17:00:48.953Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-10-31T17:01:00.949Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.5 due to current limit: Active-LoadBalancing
2025-10-31T17:01:00.964Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.8->22.5)
2025-10-31T17:01:12.949Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.4 due to current limit: Active-LoadBalancing
2025-10-31T17:01:12.960Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.5->22.3)
2025-10-31T17:01:24.949Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:01:24.960Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.3->22.0)
2025-10-31T17:01:36.945Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:01:36.960Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.0->21.8)
2025-10-31T17:01:48.945Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:01:48.957Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.8->21.5)
2025-10-31T17:02:00.945Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.8 due to current limit: Active-LoadBalancing
2025-10-31T17:02:00.957Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.5->21.3)
2025-10-31T17:02:12.941Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.6 due to current limit: Active-LoadBalancing
2025-10-31T17:02:12.957Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.3->21.0)
2025-10-31T17:02:24.941Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:02:33.316Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T17:02:33.617Z:INFO:taskCANopen.c:1787:Updated object 0x2249, 9 bytes
2025-10-31T17:02:36.941Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:02:48.937Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.4 due to current limit: Active-LoadBalancing
2025-10-31T17:03:00.937Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:03:00.949Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.3->22.0)
2025-10-31T17:03:12.937Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:03:12.949Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.0->21.8)
2025-10-31T17:03:24.933Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:03:24.949Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.8->21.5)
2025-10-31T17:03:36.933Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:03:48.933Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.0 due to current limit: Active-LoadBalancing
2025-10-31T17:03:48.945Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.9->21.7)
2025-10-31T17:04:00.929Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.3 due to current limit: Active-LoadBalancing
2025-10-31T17:04:12.929Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:04:12.941Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.1->21.8)
2025-10-31T17:04:24.929Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:04:24.941Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.8->21.5)
2025-10-31T17:04:27.324Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 4 of max 10
2025-10-31T17:04:36.929Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:04:48.925Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.5 due to current limit: Active-LoadBalancing
2025-10-31T17:05:00.925Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-10-31T17:05:12.925Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.5 due to current limit: Active-LoadBalancing
2025-10-31T17:05:12.937Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.8->22.5)
2025-10-31T17:05:24.921Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.4 due to current limit: Active-LoadBalancing
2025-10-31T17:05:24.933Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.5->22.3)
2025-10-31T17:05:36.921Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:05:36.933Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.3->22.0)
2025-10-31T17:05:48.921Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:05:48.933Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.0->21.8)
2025-10-31T17:06:00.917Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:06:00.929Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.8->21.5)
2025-10-31T17:06:12.917Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.8 due to current limit: Active-LoadBalancing
2025-10-31T17:06:12.929Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.5->21.3)
2025-10-31T17:06:24.917Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.6 due to current limit: Active-LoadBalancing
2025-10-31T17:06:24.929Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.3->21.0)
2025-10-31T17:06:36.914Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:06:48.914Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:07:00.914Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.4 due to current limit: Active-LoadBalancing
2025-10-31T17:07:03.628Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T17:07:03.929Z:INFO:taskCANopen.c:1787:Updated object 0x2249, 9 bytes
2025-10-31T17:07:12.910Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-10-31T17:07:24.910Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-10-31T17:07:24.921Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.6->22.3)
2025-10-31T17:07:36.910Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.3 due to current limit: Active-LoadBalancing
2025-10-31T17:07:36.921Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.3->22.1)
2025-10-31T17:07:48.906Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:07:48.921Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.1->21.8)
2025-10-31T17:08:00.906Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:08:00.917Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.8->21.5)
2025-10-31T17:08:12.906Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:08:24.902Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:08:24.917Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.0->21.7)
2025-10-31T17:08:36.902Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:08:36.914Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.7->21.5)
2025-10-31T17:08:41.996Z:USER:taskMaster.c:6582:Temperature: 28.2 C
2025-10-31T17:08:48.902Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:08:57.343Z:INFO:active_lb.c:308:SMt:(13.0 15.0 14.0)A Free:(3.0 1.0 2.0)A ALB:(15.6 13.2 14.6)A
2025-10-31T17:09:00.898Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.4 due to current limit: Active-LoadBalancing
2025-10-31T17:09:12.898Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.3 due to current limit: Active-LoadBalancing
2025-10-31T17:09:12.910Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.3->22.0)
2025-10-31T17:09:24.898Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:09:24.910Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.0->21.8)
2025-10-31T17:09:36.894Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.0 due to current limit: Active-LoadBalancing
2025-10-31T17:09:36.910Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.8->21.5)
2025-10-31T17:09:48.894Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:10:00.894Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.5 due to current limit: Active-LoadBalancing
2025-10-31T17:10:12.890Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-10-31T17:10:12.906Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.4->22.1)
2025-10-31T17:10:24.890Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:10:24.902Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.1->21.9)
2025-10-31T17:10:36.890Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.0 due to current limit: Active-LoadBalancing
2025-10-31T17:10:36.902Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.9->21.6)
2025-10-31T17:10:38.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T17:10:48.886Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.8 due to current limit: Active-LoadBalancing
2025-10-31T17:10:48.902Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.6->21.4)
2025-10-31T17:10:53.156Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 5 of max 10
2025-10-31T17:11:00.886Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:11:12.886Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.3 due to current limit: Active-LoadBalancing
2025-10-31T17:11:24.882Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:11:24.898Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.2->22.0)
2025-10-31T17:11:36.882Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:11:36.894Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.0->21.7)
2025-10-31T17:11:44.000Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T17:11:44.300Z:INFO:taskCANopen.c:1787:Updated object 0x2249, 9 bytes
2025-10-31T17:11:48.882Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:11:48.894Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.7->21.5)
2025-10-31T17:12:00.882Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:12:12.878Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.4 due to current limit: Active-LoadBalancing
2025-10-31T17:12:24.878Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.3 due to current limit: Active-LoadBalancing
2025-10-31T17:12:24.890Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.3->22.1)
2025-10-31T17:12:36.878Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:12:36.890Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.1->21.8)
2025-10-31T17:12:48.875Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.0 due to current limit: Active-LoadBalancing
2025-10-31T17:12:48.886Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.8->21.5)
2025-10-31T17:13:00.875Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.8 due to current limit: Active-LoadBalancing
2025-10-31T17:13:00.886Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.5->21.3)
2025-10-31T17:13:12.875Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.6 due to current limit: Active-LoadBalancing
2025-10-31T17:13:12.886Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.3->21.0)
2025-10-31T17:13:24.871Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:13:36.871Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:13:48.871Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.0 due to current limit: Active-LoadBalancing
2025-10-31T17:13:48.882Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.9->21.7)
2025-10-31T17:14:00.867Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:14:00.882Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.7->21.4)
2025-10-31T17:14:12.867Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.7 due to current limit: Active-LoadBalancing
2025-10-31T17:14:12.878Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.4->21.2)
2025-10-31T17:14:24.867Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.6 due to current limit: Active-LoadBalancing
2025-10-31T17:14:24.878Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.2->20.9)
2025-10-31T17:14:36.863Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T17:14:48.863Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:15:00.863Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.3 due to current limit: Active-LoadBalancing
2025-10-31T17:15:12.859Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.5 due to current limit: Active-LoadBalancing
2025-10-31T17:15:24.859Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.4 due to current limit: Active-LoadBalancing
2025-10-31T17:15:24.871Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.5->22.3)
2025-10-31T17:15:36.859Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:15:36.871Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.3->22.0)
2025-10-31T17:15:43.050Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=232.5V L3N=231.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T17:15:43.062Z:USER:taskMaster.c:6720:Socket #1: I1=12.9A I2=12.9A I3=12.8A P=9.0kW Idc=0.7mA
2025-10-31T17:15:48.855Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:15:48.871Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.0->21.8)
2025-10-31T17:16:00.855Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:16:00.867Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.8->21.5)
2025-10-31T17:16:12.855Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:16:24.851Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.5 due to current limit: Active-LoadBalancing
2025-10-31T17:16:36.851Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-10-31T17:16:36.863Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.4->22.2)
2025-10-31T17:16:48.851Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:16:48.863Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.2->21.9)
2025-10-31T17:17:00.847Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.0 due to current limit: Active-LoadBalancing
2025-10-31T17:17:00.863Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.9->21.7)
2025-10-31T17:17:12.847Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:17:12.859Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.7->21.5)
2025-10-31T17:17:14.617Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T17:17:14.917Z:INFO:taskCANopen.c:1787:Updated object 0x2249, 9 bytes
2025-10-31T17:17:18.992Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 6 of max 10
2025-10-31T17:17:24.847Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:17:36.843Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.4 due to current limit: Active-LoadBalancing
2025-10-31T17:17:48.843Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.3 due to current limit: Active-LoadBalancing
2025-10-31T17:17:48.855Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.3->22.1)
2025-10-31T17:18:00.843Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:18:00.855Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.1->21.8)
2025-10-31T17:18:12.839Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:18:12.855Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.8->21.5)
2025-10-31T17:18:24.839Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:18:36.839Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.5 due to current limit: Active-LoadBalancing
2025-10-31T17:18:48.835Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-10-31T17:18:48.851Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.4->22.2)
2025-10-31T17:18:57.281Z:INFO:active_lb.c:308:SMt:(14.0 16.0 14.0)A Free:(2.0 0.0 2.0)A ALB:(15.8 13.3 14.8)A
2025-10-31T17:19:00.835Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:19:00.847Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.2->21.9)
2025-10-31T17:19:12.835Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.0 due to current limit: Active-LoadBalancing
2025-10-31T17:19:12.847Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.9->21.7)
2025-10-31T17:19:24.835Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:19:24.847Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.7->21.5)
2025-10-31T17:19:36.832Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:19:48.832Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.4 due to current limit: Active-LoadBalancing
2025-10-31T17:20:00.832Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.3 due to current limit: Active-LoadBalancing
2025-10-31T17:20:00.843Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.3->22.0)
2025-10-31T17:20:12.828Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:20:12.839Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.0->21.8)
2025-10-31T17:20:24.828Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:20:24.839Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.8->21.5)
2025-10-31T17:20:36.828Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:20:48.824Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.5 due to current limit: Active-LoadBalancing
2025-10-31T17:21:00.824Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-10-31T17:21:00.835Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.4->22.2)
2025-10-31T17:21:12.824Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:21:12.835Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.2->21.9)
2025-10-31T17:21:24.820Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.0 due to current limit: Active-LoadBalancing
2025-10-31T17:21:24.835Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.9->21.7)
2025-10-31T17:21:36.820Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:21:36.832Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.7->21.5)
2025-10-31T17:21:48.820Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:21:53.984Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T17:21:54.285Z:INFO:taskCANopen.c:1787:Updated object 0x2249, 9 bytes
2025-10-31T17:22:00.816Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.4 due to current limit: Active-LoadBalancing
2025-10-31T17:22:12.816Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.3 due to current limit: Active-LoadBalancing
2025-10-31T17:22:12.828Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.3->22.0)
2025-10-31T17:22:24.816Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:22:24.828Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.0->21.8)
2025-10-31T17:22:36.812Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:22:36.828Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.8->21.5)
2025-10-31T17:22:48.812Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:23:00.812Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.0 due to current limit: Active-LoadBalancing
2025-10-31T17:23:00.824Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.9->21.7)
2025-10-31T17:23:12.808Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:23:12.824Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.7->21.5)
2025-10-31T17:23:24.808Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.8 due to current limit: Active-LoadBalancing
2025-10-31T17:23:24.820Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.5->21.3)
2025-10-31T17:23:36.808Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->11.7 due to current limit: Active-LoadBalancing
2025-10-31T17:23:36.820Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.3->19.5)
2025-10-31T17:23:37.449Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.5% (11.7 A)
2025-10-31T17:23:42.402Z:USER:taskMaster.c:6582:Temperature: 29.5 C
2025-10-31T17:23:44.804Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 7 of max 10
2025-10-31T17:23:48.804Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->9.6 due to current limit: Active-LoadBalancing
2025-10-31T17:23:48.820Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->15.9)
2025-10-31T17:23:49.566Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.9% (9.5 A)
2025-10-31T17:24:00.804Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->7.8 due to current limit: Active-LoadBalancing
2025-10-31T17:24:00.816Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.9->13.0)
2025-10-31T17:24:01.683Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.0% (7.8 A)
2025-10-31T17:24:12.804Z:INFO:taskMain.c:5996:Socket #1: Active current 7.8->6.9 due to current limit: Active-LoadBalancing
2025-10-31T17:24:12.816Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (13.0->11.5)
2025-10-31T17:24:13.804Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.5% (6.9 A)
2025-10-31T17:24:24.800Z:INFO:taskMain.c:5996:Socket #1: Active current 6.9->6.8 due to current limit: Active-LoadBalancing
2025-10-31T17:24:24.816Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.5->11.2)
2025-10-31T17:24:36.800Z:INFO:taskMain.c:5996:Socket #1: Active current 6.8->7.0 due to current limit: Active-LoadBalancing
2025-10-31T17:24:48.800Z:INFO:taskMain.c:5996:Socket #1: Active current 7.0->7.2 due to current limit: Active-LoadBalancing
2025-10-31T17:25:00.796Z:INFO:taskMain.c:5996:Socket #1: Active current 7.2->7.5 due to current limit: Active-LoadBalancing
2025-10-31T17:25:12.796Z:INFO:taskMain.c:5996:Socket #1: Active current 7.5->7.7 due to current limit: Active-LoadBalancing
2025-10-31T17:25:24.796Z:INFO:taskMain.c:5996:Socket #1: Active current 7.7->7.9 due to current limit: Active-LoadBalancing
2025-10-31T17:25:36.792Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->8.2 due to current limit: Active-LoadBalancing
2025-10-31T17:25:38.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T17:25:48.792Z:INFO:taskMain.c:5996:Socket #1: Active current 8.2->8.5 due to current limit: Active-LoadBalancing
2025-10-31T17:26:00.792Z:INFO:taskMain.c:5996:Socket #1: Active current 8.5->8.7 due to current limit: Active-LoadBalancing
2025-10-31T17:26:12.789Z:INFO:taskMain.c:5996:Socket #1: Active current 8.7->9.0 due to current limit: Active-LoadBalancing
2025-10-31T17:26:24.789Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.8 due to current limit: Active-LoadBalancing
2025-10-31T17:26:24.800Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.0->14.7)
2025-10-31T17:26:36.789Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->9.1 due to current limit: Active-LoadBalancing
2025-10-31T17:26:48.789Z:INFO:taskMain.c:5996:Socket #1: Active current 9.1->9.3 due to current limit: Active-LoadBalancing
2025-10-31T17:27:00.785Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->9.1 due to current limit: Active-LoadBalancing
2025-10-31T17:27:00.796Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.4->15.2)
2025-10-31T17:27:12.785Z:INFO:taskMain.c:5996:Socket #1: Active current 9.1->9.0 due to current limit: Active-LoadBalancing
2025-10-31T17:27:12.796Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.2->14.9)
2025-10-31T17:27:24.785Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.8 due to current limit: Active-LoadBalancing
2025-10-31T17:27:24.796Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.9->14.7)
2025-10-31T17:27:36.781Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->11.1 due to current limit: Active-LoadBalancing
2025-10-31T17:27:36.792Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.4% (11.0 A)
2025-10-31T17:27:48.781Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->13.3 due to current limit: Active-LoadBalancing
2025-10-31T17:27:48.910Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.1% (13.3 A)
2025-10-31T17:28:00.781Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->14.3 due to current limit: Active-LoadBalancing
2025-10-31T17:28:01.031Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.7% (14.2 A)
2025-10-31T17:28:12.777Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-10-31T17:28:12.789Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.7->23.5)
2025-10-31T17:28:24.777Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->13.6 due to current limit: Active-LoadBalancing
2025-10-31T17:28:24.789Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.5->22.6)
2025-10-31T17:28:25.265Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-10-31T17:28:36.777Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.0 due to current limit: Active-LoadBalancing
2025-10-31T17:28:36.789Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.6->21.6)
2025-10-31T17:28:37.386Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.6% (13.0 A)
2025-10-31T17:28:48.773Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.8 due to current limit: Active-LoadBalancing
2025-10-31T17:28:48.785Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.6->21.4)
2025-10-31T17:28:57.218Z:INFO:active_lb.c:308:SMt:(14.0 16.0 14.0)A Free:(2.0 0.0 2.0)A ALB:(14.5 12.8 14.2)A
2025-10-31T17:29:00.773Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.7 due to current limit: Active-LoadBalancing
2025-10-31T17:29:00.785Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.4->21.1)
2025-10-31T17:29:12.773Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.5 due to current limit: Active-LoadBalancing
2025-10-31T17:29:12.785Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.1->20.9)
2025-10-31T17:29:24.769Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.8 due to current limit: Active-LoadBalancing
2025-10-31T17:29:36.769Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->13.0 due to current limit: Active-LoadBalancing
2025-10-31T17:29:48.769Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.3 due to current limit: Active-LoadBalancing
2025-10-31T17:29:48.781Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.7->20.4)
2025-10-31T17:29:49.089Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.4% (12.2 A)
2025-10-31T17:30:00.765Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->10.5 due to current limit: Active-LoadBalancing
2025-10-31T17:30:00.781Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.4->17.5)
2025-10-31T17:30:01.207Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.5% (10.5 A)
2025-10-31T17:30:10.644Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 8 of max 10
2025-10-31T17:30:12.765Z:INFO:taskMain.c:5996:Socket #1: Active current 10.5->9.2 due to current limit: Active-LoadBalancing
2025-10-31T17:30:12.777Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (17.5->15.2)
2025-10-31T17:30:13.324Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.2% (9.1 A)
2025-10-31T17:30:24.765Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->8.6 due to current limit: Active-LoadBalancing
2025-10-31T17:30:24.777Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.2->14.3)
2025-10-31T17:30:25.445Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.3% (8.6 A)
2025-10-31T17:30:36.761Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->10.0 due to current limit: Active-LoadBalancing
2025-10-31T17:30:37.562Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.7% (10.0 A)
2025-10-31T17:30:42.957Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.3V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T17:30:42.968Z:USER:taskMaster.c:6720:Socket #1: I1=9.7A I2=9.7A I3=9.6A P=6.7kW Idc=0.7mA
2025-10-31T17:30:48.761Z:INFO:taskMain.c:5996:Socket #1: Active current 10.0->12.3 due to current limit: Active-LoadBalancing
2025-10-31T17:30:49.679Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.4% (12.2 A)
2025-10-31T17:31:00.761Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->14.1 due to current limit: Active-LoadBalancing
2025-10-31T17:31:00.789Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.4% (14.0 A)
2025-10-31T17:31:12.757Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.9 due to current limit: Active-LoadBalancing
2025-10-31T17:31:12.910Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.8% (14.9 A)
2025-10-31T17:31:24.757Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-10-31T17:31:24.769Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-10-31T17:31:36.757Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.2 due to current limit: Active-LoadBalancing
2025-10-31T17:31:36.769Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->23.6)
2025-10-31T17:31:37.148Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.6% (14.2 A)
2025-10-31T17:31:48.753Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->13.6 due to current limit: Active-LoadBalancing
2025-10-31T17:31:48.769Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.6->22.7)
2025-10-31T17:31:49.265Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.7% (13.6 A)
2025-10-31T17:32:00.753Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.5 due to current limit: Active-LoadBalancing
2025-10-31T17:32:00.765Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.7->22.4)
2025-10-31T17:32:12.753Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-10-31T17:32:24.750Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.6 due to current limit: Active-LoadBalancing
2025-10-31T17:32:24.765Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.8->22.6)
2025-10-31T17:32:36.750Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-10-31T17:32:36.761Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.6->22.3)
2025-10-31T17:32:48.750Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:32:48.761Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.3->22.0)
2025-10-31T17:33:00.746Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:33:00.761Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.0->21.8)
2025-10-31T17:33:12.746Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:33:12.757Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.8->21.5)
2025-10-31T17:33:24.746Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.8 due to current limit: Active-LoadBalancing
2025-10-31T17:33:24.757Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.5->21.3)
2025-10-31T17:33:36.742Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.6 due to current limit: Active-LoadBalancing
2025-10-31T17:33:36.757Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.3->21.0)
2025-10-31T17:33:48.742Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:34:00.742Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.2 due to current limit: Active-LoadBalancing
2025-10-31T17:34:12.738Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.0 due to current limit: Active-LoadBalancing
2025-10-31T17:34:12.753Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.9->21.7)
2025-10-31T17:34:24.738Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:34:24.750Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.7->21.4)
2025-10-31T17:34:36.738Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.7 due to current limit: Active-LoadBalancing
2025-10-31T17:34:36.750Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.4->21.2)
2025-10-31T17:34:48.738Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.6 due to current limit: Active-LoadBalancing
2025-10-31T17:34:48.750Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.2->20.9)
2025-10-31T17:35:00.734Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T17:35:12.734Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:35:24.734Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.3 due to current limit: Active-LoadBalancing
2025-10-31T17:35:36.730Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.1 due to current limit: Active-LoadBalancing
2025-10-31T17:35:36.742Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.1->21.8)
2025-10-31T17:35:45.523Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-10-31T17:35:45.535Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-10-31T17:35:45.542Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-10-31T17:35:45.550Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-10-31T17:35:45.582Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-10-31T17:35:46.519Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.2/-11.4, tag: 04BB29EAFD0F94
2025-10-31T17:35:48.730Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->7.9 due to current limit: Active-LoadBalancing
2025-10-31T17:35:49.550Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.1% (7.9 A)
2025-10-31T17:36:00.730Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->5.1 due to current limit: Active-LoadBalancing
2025-10-31T17:36:00.742Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.13) < minimum current(6.00)
2025-10-31T17:36:00.773Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-10-31T17:36:00.785Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-10-31T17:36:00.792Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-10-31T17:36:01.667Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-10-31T17:36:01.769Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-10-31T17:36:01.769Z:INFO:taskMain.c:1417:29EAFD0F94
2025-10-31T17:36:05.136Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T17:36:05.433Z:INFO:taskCANopen.c:1787:Updated object 0x2249, 9 bytes
2025-10-31T17:36:12.726Z:INFO:taskMain.c:5996:Socket #1: Active current 5.1->8.3 due to current limit: Active-LoadBalancing
2025-10-31T17:36:12.769Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-10-31T17:36:12.781Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-10-31T17:36:12.789Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-10-31T17:36:12.878Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-10-31T17:36:12.886Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.7% (8.2 A)
2025-10-31T17:36:13.777Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-10-31T17:36:24.726Z:INFO:taskMain.c:5996:Socket #1: Active current 8.3->10.2 due to current limit: Active-LoadBalancing
2025-10-31T17:36:24.886Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.9% (10.1 A)
2025-10-31T17:36:36.578Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 9 of max 10
2025-10-31T17:36:36.726Z:INFO:taskMain.c:5996:Socket #1: Active current 10.2->11.3 due to current limit: Active-LoadBalancing
2025-10-31T17:36:37.003Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.8% (11.3 A)
2025-10-31T17:36:42.816Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-10-31T17:36:42.828Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-10-31T17:36:43.062Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-10-31T17:36:43.070Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-10-31T17:36:43.812Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-10-31T17:36:46.816Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-10-31T17:36:46.843Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-10-31T17:36:46.851Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-10-31T17:36:47.316Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-10-31T17:36:47.328Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-10-31T17:36:47.855Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-10-31T17:36:48.343Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.2/-11.4, tag: 04BB29EAFD0F94
2025-10-31T17:36:48.722Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->12.0 due to current limit: Active-LoadBalancing
2025-10-31T17:36:49.355Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.9% (11.9 A)
2025-10-31T17:37:00.722Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-10-31T17:37:01.472Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-10-31T17:37:12.722Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T17:37:24.718Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T17:37:48.718Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T17:38:42.757Z:USER:taskMaster.c:6582:Temperature: 30.1 C
2025-10-31T17:38:57.152Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-10-31T17:40:38.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T17:40:56.394Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-31T17:40:56.402Z:INFO:db_chargingprofi:26: socket 0
2025-10-31T17:40:56.410Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-31T17:40:56.421Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-31T17:40:56.429Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-31T17:40:56.437Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-31T17:40:56.449Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-31T17:40:56.457Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-31T17:40:56.464Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-31T17:40:56.472Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-31T17:40:56.480Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-31T17:40:56.488Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-31T17:40:56.496Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-31T17:40:56.503Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-31T17:40:56.511Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-31T17:40:56.523Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-31T17:40:56.531Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-31T17:40:56.539Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-31T17:40:56.550Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-31T17:40:56.562Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-31T17:40:56.570Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-31T17:40:56.578Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-31T17:40:56.585Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-31T17:43:02.425Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 10 of max 10
2025-10-31T17:45:42.859Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=231.8V L3N=231.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T17:45:42.875Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T17:48:57.089Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(14.9 13.0 14.0)A
2025-10-31T17:53:43.160Z:USER:taskMaster.c:6582:Temperature: 28.4 C
2025-10-31T17:55:38.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T17:56:24.597Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T17:56:24.871Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T17:56:36.597Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->11.2 due to current limit: Active-LoadBalancing
2025-10-31T17:56:36.988Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.5% (11.1 A)
2025-10-31T17:56:48.597Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->10.3 due to current limit: Active-LoadBalancing
2025-10-31T17:56:49.105Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.1% (10.3 A)
2025-10-31T17:57:00.597Z:INFO:taskMain.c:5996:Socket #1: Active current 10.3->11.8 due to current limit: Active-LoadBalancing
2025-10-31T17:57:01.226Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.6% (11.8 A)
2025-10-31T17:57:12.593Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->12.7 due to current limit: Active-LoadBalancing
2025-10-31T17:57:13.343Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.1% (12.7 A)
2025-10-31T17:57:24.593Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->13.0 due to current limit: Active-LoadBalancing
2025-10-31T17:57:36.593Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->11.5 due to current limit: Active-LoadBalancing
2025-10-31T17:57:37.582Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.1% (11.5 A)
2025-10-31T17:57:48.589Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->10.1 due to current limit: Active-LoadBalancing
2025-10-31T17:57:48.691Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.8% (10.1 A)
2025-10-31T17:58:12.589Z:INFO:taskMain.c:5996:Socket #1: Active current 10.1->9.2 due to current limit: Active-LoadBalancing
2025-10-31T17:58:12.929Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.4% (9.2 A)
2025-10-31T17:58:24.585Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->8.7 due to current limit: Active-LoadBalancing
2025-10-31T17:58:25.046Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.5% (8.7 A)
2025-10-31T17:58:36.585Z:INFO:taskMain.c:5996:Socket #1: Active current 8.7->10.0 due to current limit: Active-LoadBalancing
2025-10-31T17:58:37.164Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.7% (10.0 A)
2025-10-31T17:58:48.585Z:INFO:taskMain.c:5996:Socket #1: Active current 10.0->12.0 due to current limit: Active-LoadBalancing
2025-10-31T17:58:49.285Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.0% (12.0 A)
2025-10-31T17:58:57.027Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(12.0 13.0 14.0)A
2025-10-31T17:59:00.582Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->13.0 due to current limit: Active-LoadBalancing
2025-10-31T17:59:01.402Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.6% (13.0 A)
2025-10-31T17:59:24.582Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T17:59:24.628Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-10-31T17:59:36.578Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-10-31T17:59:48.578Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-10-31T18:00:12.574Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-10-31T18:00:42.765Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=232.0V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T18:00:42.777Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T18:02:00.562Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-10-31T18:02:01.164Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-10-31T18:02:12.562Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T18:02:24.562Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T18:02:48.558Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T18:03:24.554Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T18:03:24.984Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T18:03:36.554Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.3 due to current limit: Active-LoadBalancing
2025-10-31T18:03:48.554Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.6 due to current limit: Active-LoadBalancing
2025-10-31T18:04:00.550Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T18:04:24.550Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T18:08:24.523Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T18:08:24.914Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T18:08:36.523Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T18:08:43.515Z:USER:taskMaster.c:6582:Temperature: 27.2 C
2025-10-31T18:08:48.519Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-10-31T18:08:56.964Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 12.5 14.0)A
2025-10-31T18:09:00.519Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-10-31T18:09:12.519Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-10-31T18:09:24.515Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-10-31T18:09:36.515Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-10-31T18:09:48.515Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-10-31T18:10:00.511Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-10-31T18:10:12.511Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-10-31T18:10:24.511Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-10-31T18:10:38.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T18:10:48.507Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T18:11:36.503Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T18:11:36.792Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T18:11:48.503Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T18:12:12.500Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T18:14:00.488Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T18:14:01.207Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T18:14:12.488Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T18:14:36.484Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T18:15:00.480Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.6 due to current limit: Active-LoadBalancing
2025-10-31T18:15:00.792Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T18:15:12.480Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.3 due to current limit: Active-LoadBalancing
2025-10-31T18:15:24.480Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-10-31T18:15:42.671Z:USER:taskMaster.c:6684:Socket #1: L1N=235.4V L2N=233.8V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T18:15:42.683Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T18:15:48.476Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-10-31T18:16:12.472Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-10-31T18:16:12.488Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-10-31T18:16:24.472Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.3 due to current limit: Active-LoadBalancing
2025-10-31T18:16:36.472Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-10-31T18:17:00.468Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.5 due to current limit: Active-LoadBalancing
2025-10-31T18:17:00.960Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-10-31T18:17:12.468Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-10-31T18:17:24.468Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-10-31T18:17:36.464Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-10-31T18:17:48.464Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-10-31T18:18:00.464Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-10-31T18:18:24.460Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T18:18:56.902Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-10-31T18:20:00.449Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T18:20:00.718Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T18:20:12.449Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-10-31T18:20:24.449Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-10-31T18:20:48.445Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-10-31T18:21:48.437Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-10-31T18:21:48.777Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-10-31T18:22:00.437Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T18:22:12.437Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T18:22:36.433Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T18:23:43.921Z:USER:taskMaster.c:6582:Temperature: 26.5 C
2025-10-31T18:25:24.417Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T18:25:24.894Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T18:25:36.414Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T18:25:38.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T18:26:00.414Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T18:28:56.835Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-10-31T18:30:42.578Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=233.2V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T18:30:42.589Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T18:37:00.343Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T18:37:00.710Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-10-31T18:37:12.339Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-10-31T18:37:24.339Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T18:37:36.339Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T18:38:00.335Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T18:38:44.324Z:USER:taskMaster.c:6582:Temperature: 26.1 C
2025-10-31T18:38:48.675Z:INFO:heap_trace.c:493:free: 69512/160768 (43.2%) min: 43840 (27.3%) alloc #: 195
2025-10-31T18:38:48.687Z:INFO:heap_trace.c:495:fragm: 28.7% 4K: 11.6% free blocks: # 10 largest: 49560
2025-10-31T18:38:56.773Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-10-31T18:40:38.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T18:41:03.964Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-31T18:41:03.972Z:INFO:db_chargingprofi:26: socket 0
2025-10-31T18:41:03.980Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-31T18:41:03.992Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-31T18:41:04.000Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-31T18:41:04.007Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-31T18:41:04.019Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-31T18:41:04.027Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-31T18:41:04.035Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-31T18:41:04.042Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-31T18:41:04.050Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-31T18:41:04.058Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-31T18:41:04.066Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-31T18:41:04.074Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-31T18:41:04.082Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-31T18:41:04.093Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-31T18:41:04.101Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-31T18:41:04.109Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-31T18:41:04.121Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-31T18:41:04.128Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-31T18:41:04.136Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-31T18:41:04.144Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-31T18:41:04.152Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-31T18:43:24.300Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T18:43:24.472Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-10-31T18:43:36.300Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T18:44:00.296Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.5 due to current limit: Active-LoadBalancing
2025-10-31T18:44:00.828Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-10-31T18:44:12.296Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-10-31T18:44:24.296Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-10-31T18:44:48.292Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T18:45:36.289Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T18:45:36.769Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T18:45:42.480Z:USER:taskMaster.c:6684:Socket #1: L1N=231.6V L2N=231.0V L3N=229.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T18:45:42.492Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T18:45:48.289Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-10-31T18:46:00.285Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-10-31T18:46:24.285Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-10-31T18:48:56.710Z:INFO:active_lb.c:308:SMt:(1.0 4.0 2.0)A Free:(15.0 12.0 14.0)A ALB:(14.4 12.0 14.0)A
2025-10-31T18:50:24.257Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-10-31T18:50:24.589Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-10-31T18:50:36.257Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T18:50:48.253Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T18:51:12.253Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T18:52:24.246Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T18:52:24.765Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T18:52:36.246Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-10-31T18:52:48.242Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-10-31T18:53:12.242Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-10-31T18:53:44.679Z:USER:taskMaster.c:6582:Temperature: 25.8 C
2025-10-31T18:55:38.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T18:55:48.222Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-10-31T18:55:48.765Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-10-31T18:56:00.222Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-10-31T18:56:12.222Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-10-31T18:56:24.218Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-10-31T18:56:36.218Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-10-31T18:56:48.218Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-10-31T18:57:00.214Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-10-31T18:57:12.214Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-10-31T18:57:36.210Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.5 due to current limit: Active-LoadBalancing
2025-10-31T18:57:36.824Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-10-31T18:57:48.210Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-10-31T18:58:00.210Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-10-31T18:58:12.207Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-10-31T18:58:13.179Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-10-31T18:58:24.207Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-10-31T18:58:36.207Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->11.8 due to current limit: Active-LoadBalancing
2025-10-31T18:58:36.406Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.6% (11.8 A)
2025-10-31T18:58:56.648Z:INFO:active_lb.c:308:SMt:(1.0 4.0 2.0)A Free:(15.0 12.0 14.0)A ALB:(15.0 11.9 14.0)A
2025-10-31T18:59:00.203Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.9 due to current limit: Active-LoadBalancing
2025-10-31T19:00:42.386Z:USER:taskMaster.c:6684:Socket #1: L1N=231.8V L2N=232.0V L3N=231.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T19:00:42.398Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T19:01:00.191Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-10-31T19:01:00.820Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-10-31T19:01:12.191Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T19:01:24.187Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T19:01:48.187Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.5 due to current limit: Active-LoadBalancing
2025-10-31T19:01:48.285Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-10-31T19:02:00.183Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-10-31T19:02:12.183Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-10-31T19:02:36.179Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T19:03:00.179Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T19:03:01.000Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T19:03:12.175Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.3 due to current limit: Active-LoadBalancing
2025-10-31T19:03:24.175Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-10-31T19:03:48.171Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-10-31T19:04:00.171Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.4 due to current limit: Active-LoadBalancing
2025-10-31T19:04:00.582Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-10-31T19:04:12.171Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.7 due to current limit: Active-LoadBalancing
2025-10-31T19:04:24.167Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.4 due to current limit: Active-LoadBalancing
2025-10-31T19:04:36.167Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T19:04:48.167Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T19:05:12.164Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T19:08:45.085Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-10-31T19:08:56.585Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-10-31T19:09:24.136Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T19:09:24.757Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T19:09:36.136Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T19:10:00.132Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T19:10:38.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T19:12:24.117Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T19:12:24.519Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T19:12:36.117Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-10-31T19:12:48.117Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-10-31T19:13:12.113Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.5 due to current limit: Active-LoadBalancing
2025-10-31T19:13:24.113Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-10-31T19:13:36.109Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-10-31T19:14:00.109Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T19:15:42.292Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=233.3V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T19:15:42.304Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T19:18:00.082Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T19:18:00.812Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T19:18:12.082Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T19:18:36.078Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T19:18:56.519Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 12.9 14.0)A
2025-10-31T19:23:45.441Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-10-31T19:25:00.039Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T19:25:00.929Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-10-31T19:25:12.085Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-10-31T19:25:24.085Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T19:25:36.085Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T19:25:38.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T19:26:00.082Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T19:28:56.457Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-10-31T19:30:42.195Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=234.9V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T19:30:42.210Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T19:38:45.847Z:USER:taskMaster.c:6582:Temperature: 25.0 C
2025-10-31T19:38:56.394Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(14.9 13.0 14.0)A
2025-10-31T19:40:38.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T19:41:11.535Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-31T19:41:11.542Z:INFO:db_chargingprofi:26: socket 0
2025-10-31T19:41:11.550Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-31T19:41:11.562Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-31T19:41:11.570Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-31T19:41:11.578Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-31T19:41:11.589Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-31T19:41:11.597Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-31T19:41:11.605Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-31T19:41:11.613Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-31T19:41:11.621Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-31T19:41:11.628Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-31T19:41:11.636Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-31T19:41:11.644Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-31T19:41:11.652Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-31T19:41:11.664Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-31T19:41:11.671Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-31T19:41:11.679Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-31T19:41:11.691Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-31T19:41:11.699Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-31T19:41:11.707Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-31T19:41:11.714Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-31T19:41:11.722Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-31T19:45:42.101Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=233.8V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T19:45:42.117Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T19:45:48.007Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T19:45:48.148Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-10-31T19:46:00.007Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T19:46:12.003Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-10-31T19:46:24.003Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-10-31T19:46:36.003Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.6 due to current limit: Active-LoadBalancing
2025-10-31T19:46:48.000Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.3 due to current limit: Active-LoadBalancing
2025-10-31T19:47:00.000Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.6 due to current limit: Active-LoadBalancing
2025-10-31T19:47:12.000Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-10-31T19:47:23.996Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T19:47:35.996Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T19:47:59.992Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T19:48:56.332Z:INFO:active_lb.c:308:SMt:(2.0 3.0 2.0)A Free:(14.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-10-31T19:50:35.976Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T19:50:36.976Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T19:50:47.976Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-10-31T19:50:59.972Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-10-31T19:51:11.972Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-10-31T19:51:12.324Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-10-31T19:51:23.972Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-10-31T19:51:35.968Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-10-31T19:51:59.968Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-10-31T19:52:11.968Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.4 due to current limit: Active-LoadBalancing
2025-10-31T19:52:12.917Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-10-31T19:52:23.964Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.7 due to current limit: Active-LoadBalancing
2025-10-31T19:52:35.964Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-10-31T19:52:59.960Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T19:53:46.250Z:USER:taskMaster.c:6582:Temperature: 24.8 C
2025-10-31T19:54:23.953Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T19:54:24.203Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T19:54:35.953Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T19:54:47.949Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-10-31T19:54:59.949Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-10-31T19:55:11.949Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.6 due to current limit: Active-LoadBalancing
2025-10-31T19:55:23.945Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.7 due to current limit: Active-LoadBalancing
2025-10-31T19:55:35.996Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-10-31T19:55:38.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T19:55:59.992Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T19:57:47.980Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T19:57:48.203Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T19:57:59.980Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T19:58:23.976Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T19:58:56.269Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-10-31T20:00:42.007Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=234.1V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T20:00:42.019Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T20:01:35.957Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.8 due to current limit: Active-LoadBalancing
2025-10-31T20:01:47.957Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->13.0 due to current limit: Active-LoadBalancing
2025-10-31T20:05:23.933Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.8 due to current limit: Active-LoadBalancing
2025-10-31T20:05:35.933Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->13.0 due to current limit: Active-LoadBalancing
2025-10-31T20:08:46.605Z:USER:taskMaster.c:6582:Temperature: 24.5 C
2025-10-31T20:08:56.203Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-10-31T20:10:38.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T20:15:41.910Z:USER:taskMaster.c:6684:Socket #1: L1N=235.4V L2N=235.6V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T20:15:41.925Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T20:18:56.140Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-10-31T20:23:47.011Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-10-31T20:25:38.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T20:28:56.078Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-10-31T20:30:41.816Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=232.4V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T20:30:41.828Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T20:38:40.640Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T20:38:40.910Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-10-31T20:38:47.367Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-10-31T20:38:47.914Z:INFO:heap_trace.c:493:free: 69512/160768 (43.2%) min: 43840 (27.3%) alloc #: 195
2025-10-31T20:38:47.925Z:INFO:heap_trace.c:495:fragm: 28.7% 4K: 11.6% free blocks: # 10 largest: 49560
2025-10-31T20:38:56.015Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-10-31T20:38:59.718Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T20:39:00.421Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-10-31T20:39:11.718Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-10-31T20:39:23.718Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-10-31T20:39:47.714Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-10-31T20:39:59.714Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.4 due to current limit: Active-LoadBalancing
2025-10-31T20:40:00.003Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-10-31T20:40:11.710Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.7 due to current limit: Active-LoadBalancing
2025-10-31T20:40:23.710Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-10-31T20:40:38.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T20:40:47.707Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T20:41:19.105Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-31T20:41:19.113Z:INFO:db_chargingprofi:26: socket 0
2025-10-31T20:41:19.121Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-31T20:41:19.128Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-31T20:41:19.136Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-31T20:41:19.148Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-31T20:41:19.156Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-31T20:41:19.164Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-31T20:41:19.175Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-31T20:41:19.183Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-31T20:41:19.191Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-31T20:41:19.199Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-31T20:41:19.207Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-31T20:41:19.214Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-31T20:41:19.222Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-31T20:41:19.230Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-31T20:41:19.242Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-31T20:41:19.250Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-31T20:41:19.257Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-31T20:41:19.265Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-31T20:41:19.273Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-31T20:41:19.281Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-31T20:41:19.289Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-31T20:41:35.703Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T20:41:35.945Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T20:41:47.703Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-10-31T20:41:59.703Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-10-31T20:42:23.699Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-10-31T20:43:23.691Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-10-31T20:43:24.003Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-10-31T20:43:35.691Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T20:43:47.691Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T20:44:11.687Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T20:45:23.679Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T20:45:24.179Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T20:45:35.679Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-10-31T20:45:41.722Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.1V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T20:45:41.734Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T20:45:47.675Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-10-31T20:46:11.675Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-10-31T20:48:55.953Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 12.0 14.0)A
2025-10-31T20:48:59.656Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-10-31T20:49:00.296Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-10-31T20:49:11.656Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-10-31T20:49:35.652Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.5 due to current limit: Active-LoadBalancing
2025-10-31T20:49:36.652Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-10-31T20:49:47.652Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-10-31T20:49:59.652Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.4 due to current limit: Active-LoadBalancing
2025-10-31T20:50:11.648Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-10-31T20:50:23.648Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-10-31T20:50:35.648Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-10-31T20:50:47.644Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-10-31T20:51:11.644Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-10-31T20:53:47.769Z:USER:taskMaster.c:6582:Temperature: 24.1 C
2025-10-31T20:55:38.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T20:55:59.613Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-10-31T20:56:00.414Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-10-31T20:56:11.609Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T20:56:23.609Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T20:56:47.605Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T20:57:23.605Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T20:57:24.234Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T20:57:35.601Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.3 due to current limit: Active-LoadBalancing
2025-10-31T20:57:47.601Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-10-31T20:58:11.597Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-10-31T20:58:55.886Z:INFO:active_lb.c:308:SMt:(1.0 4.0 2.0)A Free:(15.0 12.0 14.0)A ALB:(15.0 12.0 14.0)A
2025-10-31T21:00:41.625Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=235.3V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T21:00:41.640Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T21:01:35.625Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-10-31T21:01:35.695Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-10-31T21:01:47.625Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T21:01:59.625Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T21:02:23.621Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T21:02:47.621Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T21:02:48.410Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T21:02:59.617Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.3 due to current limit: Active-LoadBalancing
2025-10-31T21:03:11.617Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-10-31T21:03:23.617Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->11.7 due to current limit: Active-LoadBalancing
2025-10-31T21:03:23.746Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.5% (11.7 A)
2025-10-31T21:03:35.613Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.8 due to current limit: Active-LoadBalancing
2025-10-31T21:03:59.660Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.9 due to current limit: Active-LoadBalancing
2025-10-31T21:05:47.648Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-10-31T21:05:48.160Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-10-31T21:05:59.648Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T21:06:11.648Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T21:06:35.644Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T21:06:47.644Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.6 due to current limit: Active-LoadBalancing
2025-10-31T21:06:47.742Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T21:06:59.644Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.3 due to current limit: Active-LoadBalancing
2025-10-31T21:07:11.640Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-10-31T21:07:35.640Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-10-31T21:08:47.632Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-10-31T21:08:47.921Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-10-31T21:08:48.175Z:USER:taskMaster.c:6582:Temperature: 24.0 C
2025-10-31T21:08:55.824Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 12.4 14.0)A
2025-10-31T21:08:59.628Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T21:09:11.628Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T21:09:35.625Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T21:10:38.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T21:10:47.617Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T21:10:48.097Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T21:10:59.617Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-10-31T21:11:11.617Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-10-31T21:11:35.613Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-10-31T21:13:23.601Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-10-31T21:13:23.613Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-10-31T21:13:35.601Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T21:13:47.597Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T21:14:11.597Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T21:15:35.589Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T21:15:35.906Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T21:15:41.531Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.0V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T21:15:41.542Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T21:15:47.585Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-10-31T21:15:59.585Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-10-31T21:16:23.582Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-10-31T21:17:35.574Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-10-31T21:17:36.085Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-10-31T21:17:47.574Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T21:17:59.574Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T21:18:23.570Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T21:18:55.761Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-10-31T21:23:23.539Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.8 due to current limit: Active-LoadBalancing
2025-10-31T21:23:24.500Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.9% (13.7 A)
2025-10-31T21:23:35.539Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->14.0 due to current limit: Active-LoadBalancing
2025-10-31T21:23:48.531Z:USER:taskMaster.c:6582:Temperature: 23.6 C
2025-10-31T21:25:38.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T21:26:35.519Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.4 due to current limit: Active-LoadBalancing
2025-10-31T21:26:36.378Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-10-31T21:26:47.515Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-10-31T21:27:11.515Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.7 due to current limit: Active-LoadBalancing
2025-10-31T21:27:11.722Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.1% (12.7 A)
2025-10-31T21:27:23.511Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.4 due to current limit: Active-LoadBalancing
2025-10-31T21:27:35.511Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T21:27:47.511Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T21:28:11.507Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T21:28:55.699Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-10-31T21:30:41.437Z:USER:taskMaster.c:6684:Socket #1: L1N=233.2V L2N=233.0V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T21:30:41.449Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T21:35:30.695Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T21:35:31.472Z:SECURITY:httpd_login.c:155:WebClient connected (account: admin)
2025-10-31T21:35:31.566Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-10-31T21:38:48.933Z:USER:taskMaster.c:6582:Temperature: 23.9 C
2025-10-31T21:38:55.632Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-10-31T21:39:59.433Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.8 due to current limit: Active-LoadBalancing
2025-10-31T21:40:00.253Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.9% (13.7 A)
2025-10-31T21:40:11.433Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->14.0 due to current limit: Active-LoadBalancing
2025-10-31T21:40:38.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T21:41:26.671Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-31T21:41:26.683Z:INFO:db_chargingprofi:26: socket 0
2025-10-31T21:41:26.691Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-31T21:41:26.699Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-31T21:41:26.707Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-31T21:41:26.714Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-31T21:41:26.726Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-31T21:41:26.734Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-31T21:41:26.742Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-31T21:41:26.750Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-31T21:41:26.757Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-31T21:41:26.765Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-31T21:41:26.773Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-31T21:41:26.781Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-31T21:41:26.789Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-31T21:41:26.800Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-31T21:41:26.808Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-31T21:41:26.816Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-31T21:41:26.828Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-31T21:41:26.835Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-31T21:41:26.843Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-31T21:41:26.851Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-31T21:41:26.859Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-31T21:43:23.460Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-10-31T21:43:24.250Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-10-31T21:43:35.460Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.3 due to current limit: Active-LoadBalancing
2025-10-31T21:43:47.460Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->12.8 due to current limit: Active-LoadBalancing
2025-10-31T21:43:47.472Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.3% (12.8 A)
2025-10-31T21:44:11.457Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T21:45:02.503Z:WARNING:web_functionali:139:Could not find prop dwId 2081.00
2025-10-31T21:45:02.511Z:SECURITY:web_functionalit:58:Changed '2076_00' from 'Last Mile Solutions (KPN)' => ''
2025-10-31T21:45:02.523Z:SECURITY:web_functionalit:63:Changed '20f0_0e' from 0 => 1
2025-10-31T21:45:02.531Z:SECURITY:web_functionalit:58:Changed '20F0_03' from 'ws://ws.evc-net.com/' => 'ws://192.168.178.160:9000/'
2025-10-31T21:45:03.078Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T21:45:03.128Z:INFO:taskCANopen.c:1787:Updated object 0x2076, 51 bytes
2025-10-31T21:45:03.324Z:INFO:taskCANopen.c:1787:Updated object 0x20f0, 1142 bytes
2025-10-31T21:45:11.847Z:SECURITY:web_functionalit:68:Changed '2187_00' from 1761928643764 => 1761947112615
2025-10-31T21:45:12.121Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-10-31T21:45:12.375Z:INFO:taskCANopen.c:1787:Updated object 0x2187, 8 bytes
2025-10-31T21:45:18.886Z:SECURITY:web_functionali:105:Webserver logout client 1
2025-10-31T21:45:18.906Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-31T21:45:19.003Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-31T21:45:41.339Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.4V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T21:45:41.351Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T21:46:02.511Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-10-31T21:46:02.812Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-31T21:46:03.132Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-10-31T21:46:03.222Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-10-31T21:46:03.636Z:SECURITY:web_functionalit:68:Changed '2059_00' from 1761947165579 => 1761947165342
2025-10-31T21:46:13.808Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x50)
2025-10-31T21:46:13.816Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-10-31T21:46:13.882Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-10-31T21:47:24.785Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T21:47:24.937Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T21:47:36.785Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T21:48:00.781Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-10-31T21:48:56.921Z:INFO:active_lb.c:308:SMt:(1.0 4.0 2.0)A Free:(15.0 12.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-10-31T21:49:00.777Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T21:49:00.875Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T21:49:12.773Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-10-31T21:49:24.773Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-10-31T21:49:36.773Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-10-31T21:49:48.769Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-10-31T21:50:12.769Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-10-31T21:53:00.750Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-10-31T21:53:01.230Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-10-31T21:53:12.750Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T21:53:24.746Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-10-31T21:53:36.746Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-10-31T21:53:50.640Z:USER:taskMaster.c:6582:Temperature: 23.9 C
2025-10-31T21:54:00.742Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-10-31T21:54:48.738Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.8 due to current limit: Active-LoadBalancing
2025-10-31T21:54:49.289Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.3% (12.8 A)
2025-10-31T21:55:00.738Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->13.3 due to current limit: Active-LoadBalancing
2025-10-31T21:55:01.406Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.1% (13.3 A)
2025-10-31T21:55:12.734Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.6 due to current limit: Active-LoadBalancing
2025-10-31T21:55:24.734Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.7 due to current limit: Active-LoadBalancing
2025-10-31T21:55:36.734Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-10-31T21:55:38.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T21:56:12.730Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->14.0 due to current limit: Active-LoadBalancing
2025-10-31T21:57:48.718Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-10-31T21:57:49.039Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-10-31T21:58:00.718Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.0 due to current limit: Active-LoadBalancing
2025-10-31T21:58:01.160Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.5% (12.9 A)
2025-10-31T21:58:12.718Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-10-31T21:58:13.277Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-10-31T21:58:24.714Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.3 due to current limit: Active-LoadBalancing
2025-10-31T21:58:36.714Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-10-31T21:58:56.855Z:INFO:active_lb.c:308:SMt:(1.0 4.0 2.0)A Free:(15.0 12.0 14.0)A ALB:(14.8 12.1 14.0)A
2025-10-31T21:59:00.710Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-10-31T21:59:48.707Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-10-31T21:59:49.218Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-10-31T22:00:00.707Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-10-31T22:00:12.703Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-10-31T22:00:24.703Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->13.0 due to current limit: Active-LoadBalancing
2025-10-31T22:00:25.574Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.7% (13.0 A)
2025-10-31T22:00:36.703Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-10-31T22:00:37.691Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-10-31T22:00:42.597Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.3V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T22:00:42.609Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T22:00:48.699Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.7 due to current limit: Active-LoadBalancing
2025-10-31T22:01:00.699Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-10-31T22:01:24.695Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-10-31T22:08:51.042Z:USER:taskMaster.c:6582:Temperature: 23.8 C
2025-10-31T22:08:56.792Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(14.8 14.1 14.0)A
2025-10-31T22:10:38.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T22:15:42.500Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=234.9V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T22:15:42.511Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T22:18:56.730Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.0 14.0 14.0)A
2025-10-31T22:23:51.449Z:USER:taskMaster.c:6582:Temperature: 23.8 C
2025-10-31T22:25:38.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T22:28:56.667Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.0 14.0 14.0)A
2025-10-31T22:30:42.406Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=237.1V L3N=236.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T22:30:42.417Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T22:38:48.503Z:INFO:heap_trace.c:493:free: 69416/160768 (43.2%) min: 43808 (27.2%) alloc #: 197
2025-10-31T22:38:48.515Z:INFO:heap_trace.c:495:fragm: 28.6% 4K: 11.5% free blocks: # 11 largest: 49560
2025-10-31T22:38:51.804Z:USER:taskMaster.c:6582:Temperature: 23.5 C
2025-10-31T22:38:56.601Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.0 14.0 14.0)A
2025-10-31T22:40:38.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T22:41:35.589Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-31T22:41:35.597Z:INFO:db_chargingprofi:26: socket 0
2025-10-31T22:41:35.605Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-31T22:41:35.613Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-31T22:41:35.621Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-31T22:41:35.632Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-31T22:41:35.644Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-31T22:41:35.652Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-31T22:41:35.660Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-31T22:41:35.667Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-31T22:41:35.675Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-31T22:41:35.683Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-31T22:41:35.691Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-31T22:41:35.699Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-31T22:41:35.707Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-31T22:41:35.718Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-31T22:41:35.726Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-31T22:41:35.734Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-31T22:41:35.746Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-31T22:41:35.753Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-31T22:41:35.761Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-31T22:41:35.769Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-31T22:41:35.777Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-31T22:45:42.359Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.4V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T22:45:42.371Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T22:48:56.539Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.0 14.0 14.0)A
2025-10-31T22:52:24.375Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.7 due to current limit: Active-LoadBalancing
2025-10-31T22:52:36.371Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.4 due to current limit: Active-LoadBalancing
2025-10-31T22:52:48.371Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.7 due to current limit: Active-LoadBalancing
2025-10-31T22:53:00.371Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-10-31T22:53:24.367Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-10-31T22:53:52.207Z:USER:taskMaster.c:6582:Temperature: 23.6 C
2025-10-31T22:55:38.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T22:58:56.476Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.0 14.0 14.0)A
2025-10-31T23:00:00.070Z:INFO:taskMaster.c:6353:Socket #1: external current limit 15.9 A until 2025-11-01T23:00:00Z
2025-10-31T23:00:00.085Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-10-31T23:00:00.093Z:INFO:db_chargingprofi:26: socket 0
2025-10-31T23:00:00.101Z:INFO:db_chargingprofi:27: primary Not specified
2025-10-31T23:00:00.109Z:INFO:db_chargingprofi:27: stackLevel 0
2025-10-31T23:00:00.117Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-10-31T23:00:00.125Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-10-31T23:00:00.136Z:INFO:db_chargingprofi:27: kindType Relative
2025-10-31T23:00:00.144Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-10-31T23:00:00.156Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-10-31T23:00:00.164Z:INFO:db_chargingprofi:28: validFrom NULL
2025-10-31T23:00:00.171Z:INFO:db_chargingprofi:28: validTo NULL
2025-10-31T23:00:00.179Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-10-31T23:00:00.187Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-10-31T23:00:00.195Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-10-31T23:00:00.203Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-10-31T23:00:00.210Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-10-31T23:00:00.222Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-10-31T23:00:00.230Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-10-31T23:00:00.238Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-10-31T23:00:00.246Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-10-31T23:00:00.253Z:INFO:db_chargingprofi:29: startPeriod 0
2025-10-31T23:00:00.261Z:INFO:db_chargingprofi:29: limit 15.90
2025-10-31T23:00:00.269Z:INFO:db_chargingprofi:29: numberPhases 3
2025-10-31T23:00:42.265Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.4V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T23:00:42.277Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T23:01:12.367Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-10-31T23:01:13.308Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-10-31T23:01:24.367Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-10-31T23:01:48.363Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.5 due to current limit: Active-LoadBalancing
2025-10-31T23:02:00.363Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-10-31T23:02:12.359Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-10-31T23:02:24.359Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.5 due to current limit: Active-LoadBalancing
2025-10-31T23:02:25.007Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.5% (13.5 A)
2025-10-31T23:02:36.359Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-10-31T23:02:48.355Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-10-31T23:03:00.355Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.5 due to current limit: Active-LoadBalancing
2025-10-31T23:03:00.367Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-10-31T23:03:12.355Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-10-31T23:03:24.351Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-10-31T23:03:48.351Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.5 due to current limit: Active-LoadBalancing
2025-10-31T23:03:48.832Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.5% (13.5 A)
2025-10-31T23:04:00.347Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-10-31T23:04:12.347Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-10-31T23:04:36.343Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-10-31T23:08:52.664Z:USER:taskMaster.c:6582:Temperature: 23.4 C
2025-10-31T23:08:56.414Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.0 14.0 14.6)A
2025-10-31T23:10:24.308Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.2 due to current limit: Active-LoadBalancing
2025-10-31T23:10:38.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T23:10:48.304Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-10-31T23:13:36.289Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-10-31T23:13:36.589Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-10-31T23:13:48.289Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-10-31T23:14:00.285Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-10-31T23:14:12.285Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-10-31T23:14:36.332Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-10-31T23:15:42.167Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=232.7V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T23:15:42.179Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T23:16:12.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-10-31T23:16:13.121Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-10-31T23:16:24.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-10-31T23:16:36.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-10-31T23:17:00.316Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-10-31T23:18:56.347Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-10-31T23:23:12.277Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-10-31T23:23:13.238Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-10-31T23:23:24.277Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-10-31T23:23:36.273Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-10-31T23:23:53.066Z:USER:taskMaster.c:6582:Temperature: 23.4 C
2025-10-31T23:24:00.273Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-10-31T23:24:12.269Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-10-31T23:24:12.820Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-10-31T23:24:24.269Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-10-31T23:24:36.269Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-10-31T23:24:48.265Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-10-31T23:25:00.265Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-10-31T23:25:36.261Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.9 due to current limit: Active-LoadBalancing
2025-10-31T23:25:38.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T23:26:12.257Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.0 due to current limit: Active-LoadBalancing
2025-10-31T23:28:24.246Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-10-31T23:28:24.273Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-10-31T23:28:36.242Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-10-31T23:28:48.242Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.5 due to current limit: Active-LoadBalancing
2025-10-31T23:28:56.285Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(15.0 15.0 14.5)A
2025-10-31T23:29:00.242Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-10-31T23:29:12.238Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-10-31T23:29:24.238Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-10-31T23:29:36.238Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-10-31T23:30:00.234Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.6 due to current limit: Active-LoadBalancing
2025-10-31T23:30:12.234Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-10-31T23:30:24.230Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-10-31T23:30:36.230Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.3 due to current limit: Active-LoadBalancing
2025-10-31T23:30:42.074Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=234.1V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T23:30:42.085Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T23:30:48.230Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-10-31T23:31:12.226Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-10-31T23:31:24.226Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-10-31T23:31:25.046Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-10-31T23:31:36.222Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-10-31T23:31:48.222Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.4 due to current limit: Active-LoadBalancing
2025-10-31T23:32:00.222Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-10-31T23:32:24.218Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-10-31T23:32:36.218Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.5 due to current limit: Active-LoadBalancing
2025-10-31T23:32:36.746Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-10-31T23:32:48.214Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-10-31T23:33:00.214Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.4 due to current limit: Active-LoadBalancing
2025-10-31T23:33:12.214Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-10-31T23:33:36.210Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-10-31T23:34:00.207Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-10-31T23:34:00.570Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-10-31T23:34:12.207Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-10-31T23:34:24.207Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-10-31T23:34:48.203Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.5 due to current limit: Active-LoadBalancing
2025-10-31T23:34:49.042Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-10-31T23:35:00.203Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-10-31T23:35:12.203Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.4 due to current limit: Active-LoadBalancing
2025-10-31T23:35:24.199Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-10-31T23:35:36.199Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-10-31T23:35:48.199Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.5 due to current limit: Active-LoadBalancing
2025-10-31T23:36:00.195Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-10-31T23:36:12.195Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-10-31T23:36:36.191Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-10-31T23:36:48.191Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.6 due to current limit: Active-LoadBalancing
2025-10-31T23:36:48.203Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-10-31T23:37:00.191Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-10-31T23:37:12.187Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-10-31T23:37:24.187Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.5 due to current limit: Active-LoadBalancing
2025-10-31T23:37:24.558Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-10-31T23:37:36.187Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-10-31T23:37:48.183Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-10-31T23:38:00.183Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.5 due to current limit: Active-LoadBalancing
2025-10-31T23:38:00.914Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-10-31T23:38:12.183Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-10-31T23:38:24.179Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-10-31T23:38:36.179Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-10-31T23:38:48.179Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-10-31T23:38:53.472Z:USER:taskMaster.c:6582:Temperature: 23.2 C
2025-10-31T23:38:56.222Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 14.8)A
2025-10-31T23:39:12.175Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.5 due to current limit: Active-LoadBalancing
2025-10-31T23:39:12.617Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-10-31T23:39:24.175Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-10-31T23:39:36.171Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-10-31T23:39:48.171Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-10-31T23:40:00.171Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-10-31T23:40:12.167Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-10-31T23:40:36.167Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-10-31T23:40:38.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T23:40:48.164Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.6 due to current limit: Active-LoadBalancing
2025-10-31T23:40:48.554Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-10-31T23:41:00.164Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.3 due to current limit: Active-LoadBalancing
2025-10-31T23:41:12.164Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-10-31T23:41:24.160Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-10-31T23:41:48.160Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-10-31T23:42:12.156Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.6 due to current limit: Active-LoadBalancing
2025-10-31T23:42:12.375Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-10-31T23:42:24.156Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.3 due to current limit: Active-LoadBalancing
2025-10-31T23:42:36.152Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-10-31T23:42:48.152Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-10-31T23:43:12.152Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.5 due to current limit: Active-LoadBalancing
2025-10-31T23:43:12.968Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-10-31T23:43:24.148Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-10-31T23:43:36.148Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-10-31T23:43:48.148Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-10-31T23:44:00.144Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-10-31T23:44:24.144Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-10-31T23:44:36.140Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-10-31T23:44:36.792Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-10-31T23:44:48.140Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-10-31T23:45:00.140Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.4 due to current limit: Active-LoadBalancing
2025-10-31T23:45:12.136Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-10-31T23:45:24.136Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-10-31T23:45:41.980Z:USER:taskMaster.c:6684:Socket #1: L1N=235.4V L2N=235.2V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-10-31T23:45:41.992Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-10-31T23:45:48.132Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-10-31T23:48:56.156Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-10-31T23:53:53.828Z:USER:taskMaster.c:6582:Temperature: 23.4 C
2025-10-31T23:55:38.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-10-31T23:58:56.093Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-01T00:00:07.640Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-01T00:00:07.652Z:INFO:db_chargingprofi:26: socket 0
2025-11-01T00:00:07.660Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-01T00:00:07.667Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-01T00:00:07.675Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-01T00:00:07.683Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-01T00:00:07.695Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-01T00:00:07.703Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-01T00:00:07.710Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-01T00:00:07.718Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-01T00:00:07.726Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-01T00:00:07.734Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-01T00:00:07.742Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-01T00:00:07.750Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-01T00:00:07.757Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-01T00:00:07.769Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-01T00:00:07.777Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-01T00:00:07.785Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-01T00:00:07.796Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-01T00:00:07.804Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-01T00:00:07.812Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-01T00:00:07.820Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-01T00:00:07.828Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-01T00:00:41.882Z:USER:taskMaster.c:6684:Socket #1: L1N=235.4V L2N=235.8V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T00:00:41.894Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T00:02:15.921Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T00:02:15.933Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T00:02:15.941Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=235.8V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T00:02:15.953Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T00:02:15.964Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T00:02:15.972Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T00:02:15.980Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T00:02:16.167Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T00:02:16.910Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T00:02:24.027Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.9 due to current limit: ChargingProfile
2025-11-01T00:02:24.070Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-01T00:02:24.988Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-01T00:02:45.968Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.4V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T00:02:45.984Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-11-01T00:03:15.894Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T00:03:15.968Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.5V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T00:03:15.980Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-11-01T00:03:36.019Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.4 due to current limit: Active-LoadBalancing
2025-11-01T00:03:36.035Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->25.6)
2025-11-01T00:03:36.066Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T00:03:36.691Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.6% (15.4 A)
2025-11-01T00:03:45.964Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=235.0V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T00:03:45.976Z:USER:taskMaster.c:6720:Socket #1: I1=14.9A I2=15.0A I3=14.9A P=10.5kW Idc=0.7mA
2025-11-01T00:03:48.019Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->14.8 due to current limit: Active-LoadBalancing
2025-11-01T00:03:48.031Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.6->24.7)
2025-11-01T00:03:48.808Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.7% (14.8 A)
2025-11-01T00:04:00.019Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.3 due to current limit: Active-LoadBalancing
2025-11-01T00:04:00.031Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->23.8)
2025-11-01T00:04:00.929Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.8% (14.3 A)
2025-11-01T00:04:12.015Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-01T00:04:12.031Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-01T00:04:15.960Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=234.9V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T00:04:15.972Z:USER:taskMaster.c:6720:Socket #1: I1=13.8A I2=13.8A I3=13.8A P=9.7kW Idc=0.7mA
2025-11-01T00:04:24.015Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.0 due to current limit: Active-LoadBalancing
2025-11-01T00:04:24.027Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.5->23.3)
2025-11-01T00:04:36.015Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.3 due to current limit: Active-LoadBalancing
2025-11-01T00:04:45.957Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=235.4V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T00:04:45.968Z:USER:taskMaster.c:6720:Socket #1: I1=13.8A I2=13.8A I3=13.8A P=9.7kW Idc=0.7mA
2025-11-01T00:04:48.011Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-01T00:05:00.011Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-01T00:05:12.011Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-01T00:05:15.953Z:USER:taskMaster.c:6684:Socket #1: L1N=231.6V L2N=232.2V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T00:05:15.964Z:USER:taskMaster.c:6720:Socket #1: I1=14.5A I2=14.6A I3=14.5A P=10.1kW Idc=0.7mA
2025-11-01T00:05:24.007Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-01T00:05:24.023Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-01T00:05:36.007Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-01T00:05:36.019Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-01T00:05:43.699Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T00:05:43.710Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T00:05:43.718Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T00:05:43.730Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T00:05:43.937Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-01T00:05:44.718Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T00:05:45.949Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=233.7V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T00:05:45.964Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T00:05:48.007Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->8.8 due to current limit: Active-LoadBalancing
2025-11-01T00:05:48.757Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.6% (8.8 A)
2025-11-01T00:06:00.003Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->11.3 due to current limit: Active-LoadBalancing
2025-11-01T00:06:00.875Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.8% (11.3 A)
2025-11-01T00:06:12.003Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->12.8 due to current limit: Active-LoadBalancing
2025-11-01T00:06:12.992Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.2% (12.7 A)
2025-11-01T00:06:15.949Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=233.4V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T00:06:15.960Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T00:06:24.003Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->13.7 due to current limit: Active-LoadBalancing
2025-11-01T00:06:24.101Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.7% (13.6 A)
2025-11-01T00:06:36.000Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->14.2 due to current limit: Active-LoadBalancing
2025-11-01T00:06:36.222Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.6% (14.2 A)
2025-11-01T00:06:45.945Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=233.5V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T00:06:45.960Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T00:06:48.000Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-01T00:07:00.000Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-01T00:07:11.996Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-01T00:07:15.941Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=233.7V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T00:07:15.953Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T00:07:15.964Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-01T00:07:35.996Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-01T00:08:54.230Z:USER:taskMaster.c:6582:Temperature: 23.9 C
2025-11-01T00:08:56.031Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-01T00:10:35.976Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-01T00:10:36.578Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-01T00:10:38.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T00:10:47.976Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T00:10:59.972Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-01T00:11:23.972Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.5 due to current limit: Active-LoadBalancing
2025-11-01T00:11:24.042Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-01T00:11:35.968Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-01T00:11:47.968Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-01T00:11:59.968Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.5 due to current limit: Active-LoadBalancing
2025-11-01T00:12:11.964Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-01T00:12:23.964Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-01T00:12:47.960Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.5 due to current limit: Active-LoadBalancing
2025-11-01T00:12:48.871Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-01T00:12:59.960Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-01T00:13:11.960Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-01T00:13:35.957Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-01T00:18:55.968Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-01T00:22:15.847Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=233.8V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T00:22:15.859Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T00:23:54.585Z:USER:taskMaster.c:6582:Temperature: 23.6 C
2025-11-01T00:25:38.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T00:28:55.902Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-01T00:37:15.750Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.2V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T00:37:15.761Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T00:38:40.304Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-01T00:38:40.574Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-01T00:38:47.742Z:INFO:heap_trace.c:493:free: 69416/160768 (43.2%) min: 43808 (27.2%) alloc #: 197
2025-11-01T00:38:47.750Z:INFO:heap_trace.c:495:fragm: 28.6% 4K: 11.5% free blocks: # 11 largest: 49560
2025-11-01T00:38:54.992Z:USER:taskMaster.c:6582:Temperature: 23.5 C
2025-11-01T00:38:55.839Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-01T00:40:38.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T00:42:47.820Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-01T00:42:48.492Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-01T00:42:59.820Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T00:43:11.820Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-01T00:43:35.816Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-01T00:44:23.812Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-01T00:44:24.429Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-01T00:44:35.808Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-01T00:44:47.808Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T00:44:59.808Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-01T00:45:23.804Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-01T00:46:59.796Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-01T00:46:59.953Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-01T00:47:11.792Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-01T00:47:23.792Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T00:47:47.789Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-01T00:48:55.777Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-01T00:52:15.656Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=235.4V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T00:52:15.667Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T00:53:47.750Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-01T00:53:47.953Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-01T00:53:55.394Z:USER:taskMaster.c:6582:Temperature: 23.4 C
2025-11-01T00:53:59.750Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T00:54:11.750Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-01T00:54:35.746Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-01T00:55:11.742Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-01T00:55:11.773Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-01T00:55:23.742Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-01T00:55:35.742Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-01T00:55:38.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T00:55:59.738Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-01T00:58:55.714Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-01T01:00:15.207Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-01T01:00:15.218Z:INFO:db_chargingprofi:26: socket 0
2025-11-01T01:00:15.226Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-01T01:00:15.234Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-01T01:00:15.242Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-01T01:00:15.250Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-01T01:00:15.261Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-01T01:00:15.269Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-01T01:00:15.277Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-01T01:00:15.285Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-01T01:00:15.292Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-01T01:00:15.300Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-01T01:00:15.312Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-01T01:00:15.320Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-01T01:00:15.328Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-01T01:00:15.335Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-01T01:00:15.343Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-01T01:00:15.351Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-01T01:00:15.363Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-01T01:00:15.371Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-01T01:00:15.378Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-01T01:00:15.386Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-01T01:00:15.394Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-01T01:01:59.699Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->12.6 due to current limit: Active-LoadBalancing
2025-11-01T01:01:59.769Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-11-01T01:02:11.699Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->11.2 due to current limit: Active-LoadBalancing
2025-11-01T01:02:11.886Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.6% (11.2 A)
2025-11-01T01:02:23.695Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->10.3 due to current limit: Active-LoadBalancing
2025-11-01T01:02:24.007Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.1% (10.3 A)
2025-11-01T01:02:35.695Z:INFO:taskMain.c:5996:Socket #1: Active current 10.3->9.4 due to current limit: Active-LoadBalancing
2025-11-01T01:02:36.125Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.6% (9.4 A)
2025-11-01T01:02:41.589Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T01:02:41.597Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T01:02:41.609Z:USER:taskMaster.c:6684:Socket #1: L1N=234.3V L2N=235.4V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T01:02:41.621Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T01:02:41.628Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T01:02:41.640Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T01:02:41.648Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T01:02:42.183Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T01:02:42.593Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T01:02:47.695Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->12.4 due to current limit: Active-LoadBalancing
2025-11-01T01:02:48.656Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-11-01T01:02:59.691Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->15.5 due to current limit: Active-LoadBalancing
2025-11-01T01:02:59.761Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.8% (15.5 A)
2025-11-01T01:03:11.636Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=233.5V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T01:03:11.648Z:USER:taskMaster.c:6720:Socket #1: I1=15.1A I2=15.1A I3=15.1A P=10.5kW Idc=0.7mA
2025-11-01T01:03:11.691Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:03:11.703Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.8->24.8)
2025-11-01T01:03:11.882Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.8% (14.9 A)
2025-11-01T01:03:23.691Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->11.9 due to current limit: Active-LoadBalancing
2025-11-01T01:03:23.703Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->19.9)
2025-11-01T01:03:24.000Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.9% (11.9 A)
2025-11-01T01:03:35.691Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->9.4 due to current limit: Active-LoadBalancing
2025-11-01T01:03:35.703Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.9->15.6)
2025-11-01T01:03:36.121Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.6% (9.4 A)
2025-11-01T01:03:41.578Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T01:03:41.632Z:USER:taskMaster.c:6684:Socket #1: L1N=234.9V L2N=235.7V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T01:03:41.648Z:USER:taskMaster.c:6720:Socket #1: I1=9.0A I2=9.0A I3=9.0A P=6.3kW Idc=0.7mA
2025-11-01T01:03:47.687Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->7.6 due to current limit: Active-LoadBalancing
2025-11-01T01:03:47.699Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.6->12.7)
2025-11-01T01:03:48.238Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.7% (7.6 A)
2025-11-01T01:03:59.687Z:INFO:taskMain.c:5996:Socket #1: Active current 7.6->6.7 due to current limit: Active-LoadBalancing
2025-11-01T01:03:59.699Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (12.7->11.1)
2025-11-01T01:04:00.355Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.1% (6.7 A)
2025-11-01T01:04:11.628Z:USER:taskMaster.c:6684:Socket #1: L1N=234.3V L2N=235.1V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T01:04:11.640Z:USER:taskMaster.c:6720:Socket #1: I1=6.4A I2=6.4A I3=6.4A P=4.4kW Idc=0.7mA
2025-11-01T01:04:11.687Z:INFO:taskMain.c:5996:Socket #1: Active current 6.7->6.6 due to current limit: Active-LoadBalancing
2025-11-01T01:04:11.699Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.1->10.9)
2025-11-01T01:04:23.683Z:INFO:taskMain.c:5996:Socket #1: Active current 6.6->7.6 due to current limit: Active-LoadBalancing
2025-11-01T01:04:24.593Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.7% (7.6 A)
2025-11-01T01:04:35.683Z:INFO:taskMain.c:5996:Socket #1: Active current 7.6->8.7 due to current limit: Active-LoadBalancing
2025-11-01T01:04:35.695Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.5% (8.7 A)
2025-11-01T01:04:41.625Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.9V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T01:04:41.640Z:USER:taskMaster.c:6720:Socket #1: I1=8.4A I2=8.4A I3=8.4A P=5.9kW Idc=0.7mA
2025-11-01T01:04:47.683Z:INFO:taskMain.c:5996:Socket #1: Active current 8.7->9.4 due to current limit: Active-LoadBalancing
2025-11-01T01:04:47.812Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.6% (9.4 A)
2025-11-01T01:04:59.679Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->10.1 due to current limit: Active-LoadBalancing
2025-11-01T01:04:59.929Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.7% (10.0 A)
2025-11-01T01:05:11.625Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.6V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T01:05:11.636Z:USER:taskMaster.c:6720:Socket #1: I1=9.7A I2=9.7A I3=9.7A P=6.8kW Idc=0.7mA
2025-11-01T01:05:11.679Z:INFO:taskMain.c:5996:Socket #1: Active current 10.1->10.3 due to current limit: Active-LoadBalancing
2025-11-01T01:05:23.679Z:INFO:taskMain.c:5996:Socket #1: Active current 10.3->9.7 due to current limit: Active-LoadBalancing
2025-11-01T01:05:23.691Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (17.1->16.2)
2025-11-01T01:05:24.167Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.2% (9.7 A)
2025-11-01T01:05:35.675Z:INFO:taskMain.c:5996:Socket #1: Active current 9.7->9.2 due to current limit: Active-LoadBalancing
2025-11-01T01:05:35.687Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (16.2->15.3)
2025-11-01T01:05:36.285Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.3% (9.2 A)
2025-11-01T01:05:41.621Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.9V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T01:05:41.632Z:USER:taskMaster.c:6720:Socket #1: I1=8.8A I2=8.8A I3=8.8A P=6.2kW Idc=0.7mA
2025-11-01T01:05:47.675Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->9.0 due to current limit: Active-LoadBalancing
2025-11-01T01:05:47.687Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.3->15.0)
2025-11-01T01:05:59.675Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.9 due to current limit: Active-LoadBalancing
2025-11-01T01:05:59.687Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.0->14.8)
2025-11-01T01:06:11.617Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.7V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T01:06:11.628Z:USER:taskMaster.c:6720:Socket #1: I1=8.6A I2=8.6A I3=8.5A P=6.0kW Idc=0.7mA
2025-11-01T01:06:11.671Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.8 due to current limit: Active-LoadBalancing
2025-11-01T01:06:11.683Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.8->14.6)
2025-11-01T01:06:23.671Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->9.0 due to current limit: Active-LoadBalancing
2025-11-01T01:06:35.671Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->9.3 due to current limit: Active-LoadBalancing
2025-11-01T01:06:41.613Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=234.8V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T01:06:41.625Z:USER:taskMaster.c:6720:Socket #1: I1=9.0A I2=9.0A I3=9.0A P=6.3kW Idc=0.7mA
2025-11-01T01:06:47.667Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->9.2 due to current limit: Active-LoadBalancing
2025-11-01T01:06:47.683Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.5->15.3)
2025-11-01T01:06:59.667Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->9.1 due to current limit: Active-LoadBalancing
2025-11-01T01:06:59.679Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.3->15.1)
2025-11-01T01:07:11.609Z:USER:taskMaster.c:6684:Socket #1: L1N=234.3V L2N=235.0V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T01:07:11.621Z:USER:taskMaster.c:6720:Socket #1: I1=8.7A I2=8.8A I3=8.7A P=6.1kW Idc=0.7mA
2025-11-01T01:07:11.667Z:INFO:taskMain.c:5996:Socket #1: Active current 9.1->8.9 due to current limit: Active-LoadBalancing
2025-11-01T01:07:11.679Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.1->14.8)
2025-11-01T01:07:23.664Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.8 due to current limit: Active-LoadBalancing
2025-11-01T01:07:23.679Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.8->14.6)
2025-11-01T01:07:35.664Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->8.6 due to current limit: Active-LoadBalancing
2025-11-01T01:07:35.675Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.6->14.3)
2025-11-01T01:07:41.609Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=235.2V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T01:07:41.621Z:USER:taskMaster.c:6720:Socket #1: I1=8.2A I2=8.3A I3=8.2A P=5.8kW Idc=0.7mA
2025-11-01T01:07:41.628Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-01T01:07:47.664Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.9 due to current limit: Active-LoadBalancing
2025-11-01T01:07:59.660Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->9.1 due to current limit: Active-LoadBalancing
2025-11-01T01:08:11.660Z:INFO:taskMain.c:5996:Socket #1: Active current 9.1->9.4 due to current limit: Active-LoadBalancing
2025-11-01T01:08:23.660Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->9.3 due to current limit: Active-LoadBalancing
2025-11-01T01:08:23.671Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.7->15.4)
2025-11-01T01:08:35.656Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->9.1 due to current limit: Active-LoadBalancing
2025-11-01T01:08:35.671Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.4->15.1)
2025-11-01T01:08:47.656Z:INFO:taskMain.c:5996:Socket #1: Active current 9.1->9.0 due to current limit: Active-LoadBalancing
2025-11-01T01:08:47.667Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.1->14.9)
2025-11-01T01:08:55.648Z:INFO:active_lb.c:308:SMt:(16.0 10.0 10.0)A Free:(0.0 6.0 6.0)A ALB:(9.0 14.6 15.0)A
2025-11-01T01:08:55.750Z:USER:taskMaster.c:6582:Temperature: 23.6 C
2025-11-01T01:08:59.656Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.8 due to current limit: Active-LoadBalancing
2025-11-01T01:08:59.667Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.9->14.6)
2025-11-01T01:09:11.652Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->8.6 due to current limit: Active-LoadBalancing
2025-11-01T01:09:11.667Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.6->14.4)
2025-11-01T01:09:23.652Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.9 due to current limit: Active-LoadBalancing
2025-11-01T01:09:35.652Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->9.2 due to current limit: Active-LoadBalancing
2025-11-01T01:09:47.648Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->9.0 due to current limit: Active-LoadBalancing
2025-11-01T01:09:47.664Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.2->15.0)
2025-11-01T01:09:59.648Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.9 due to current limit: Active-LoadBalancing
2025-11-01T01:09:59.660Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.0->14.8)
2025-11-01T01:10:11.648Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.8 due to current limit: Active-LoadBalancing
2025-11-01T01:10:11.660Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.8->14.6)
2025-11-01T01:10:23.644Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->8.6 due to current limit: Active-LoadBalancing
2025-11-01T01:10:23.660Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.6->14.3)
2025-11-01T01:10:35.644Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.9 due to current limit: Active-LoadBalancing
2025-11-01T01:10:38.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T01:10:47.644Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->9.2 due to current limit: Active-LoadBalancing
2025-11-01T01:10:59.640Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->9.4 due to current limit: Active-LoadBalancing
2025-11-01T01:11:11.640Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->9.7 due to current limit: Active-LoadBalancing
2025-11-01T01:11:23.640Z:INFO:taskMain.c:5996:Socket #1: Active current 9.7->9.6 due to current limit: Active-LoadBalancing
2025-11-01T01:11:23.652Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (16.1->15.9)
2025-11-01T01:11:35.640Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->9.4 due to current limit: Active-LoadBalancing
2025-11-01T01:11:35.652Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.9->15.6)
2025-11-01T01:11:47.636Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->9.3 due to current limit: Active-LoadBalancing
2025-11-01T01:11:47.648Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.6->15.4)
2025-11-01T01:11:59.636Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->8.7 due to current limit: Active-LoadBalancing
2025-11-01T01:11:59.648Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.4->14.5)
2025-11-01T01:12:00.046Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.5% (8.7 A)
2025-11-01T01:12:11.636Z:INFO:taskMain.c:5996:Socket #1: Active current 8.7->8.2 due to current limit: Active-LoadBalancing
2025-11-01T01:12:11.648Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.5->13.6)
2025-11-01T01:12:12.164Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.6% (8.2 A)
2025-11-01T01:12:23.632Z:INFO:taskMain.c:5996:Socket #1: Active current 8.2->8.0 due to current limit: Active-LoadBalancing
2025-11-01T01:12:23.644Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (13.6->13.4)
2025-11-01T01:12:35.632Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->7.9 due to current limit: Active-LoadBalancing
2025-11-01T01:12:35.644Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (13.4->13.1)
2025-11-01T01:12:47.632Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->7.7 due to current limit: Active-LoadBalancing
2025-11-01T01:12:47.644Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (13.1->12.8)
2025-11-01T01:12:59.628Z:INFO:taskMain.c:5996:Socket #1: Active current 7.7->7.6 due to current limit: Active-LoadBalancing
2025-11-01T01:12:59.640Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (12.8->12.5)
2025-11-01T01:13:11.628Z:INFO:taskMain.c:5996:Socket #1: Active current 7.6->7.8 due to current limit: Active-LoadBalancing
2025-11-01T01:13:23.628Z:INFO:taskMain.c:5996:Socket #1: Active current 7.8->7.7 due to current limit: Active-LoadBalancing
2025-11-01T01:13:23.640Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (13.0->12.7)
2025-11-01T01:13:35.625Z:INFO:taskMain.c:5996:Socket #1: Active current 7.7->7.9 due to current limit: Active-LoadBalancing
2025-11-01T01:13:47.625Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->8.2 due to current limit: Active-LoadBalancing
2025-11-01T01:13:59.625Z:INFO:taskMain.c:5996:Socket #1: Active current 8.2->8.4 due to current limit: Active-LoadBalancing
2025-11-01T01:14:11.621Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.3 due to current limit: Active-LoadBalancing
2025-11-01T01:14:11.632Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.0->13.8)
2025-11-01T01:14:23.621Z:INFO:taskMain.c:5996:Socket #1: Active current 8.3->8.2 due to current limit: Active-LoadBalancing
2025-11-01T01:14:23.632Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (13.8->13.6)
2025-11-01T01:14:35.621Z:INFO:taskMain.c:5996:Socket #1: Active current 8.2->8.0 due to current limit: Active-LoadBalancing
2025-11-01T01:14:35.632Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (13.6->13.3)
2025-11-01T01:14:47.617Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->7.9 due to current limit: Active-LoadBalancing
2025-11-01T01:14:47.632Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (13.3->13.0)
2025-11-01T01:14:59.617Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->8.1 due to current limit: Active-LoadBalancing
2025-11-01T01:15:11.617Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->8.4 due to current limit: Active-LoadBalancing
2025-11-01T01:15:23.613Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.6 due to current limit: Active-LoadBalancing
2025-11-01T01:15:35.613Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.9 due to current limit: Active-LoadBalancing
2025-11-01T01:15:47.613Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->9.1 due to current limit: Active-LoadBalancing
2025-11-01T01:15:59.609Z:INFO:taskMain.c:5996:Socket #1: Active current 9.1->9.4 due to current limit: Active-LoadBalancing
2025-11-01T01:16:11.609Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->9.7 due to current limit: Active-LoadBalancing
2025-11-01T01:16:23.609Z:INFO:taskMain.c:5996:Socket #1: Active current 9.7->9.5 due to current limit: Active-LoadBalancing
2025-11-01T01:16:23.621Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (16.0->15.8)
2025-11-01T01:16:35.605Z:INFO:taskMain.c:5996:Socket #1: Active current 9.5->9.4 due to current limit: Active-LoadBalancing
2025-11-01T01:16:35.621Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.8->15.5)
2025-11-01T01:16:47.605Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->11.6 due to current limit: Active-LoadBalancing
2025-11-01T01:16:47.867Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.3% (11.6 A)
2025-11-01T01:16:59.605Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->13.8 due to current limit: Active-LoadBalancing
2025-11-01T01:16:59.984Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-01T01:17:11.601Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->15.9 due to current limit: ChargingProfile
2025-11-01T01:17:11.648Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-01T01:17:12.101Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-01T01:17:47.597Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.5 due to current limit: Active-LoadBalancing
2025-11-01T01:17:47.613Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->25.7)
2025-11-01T01:17:47.644Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T01:17:48.460Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.7% (15.4 A)
2025-11-01T01:17:59.597Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:17:59.609Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->24.8)
2025-11-01T01:18:00.578Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.8% (14.9 A)
2025-11-01T01:18:11.597Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.3 due to current limit: Active-LoadBalancing
2025-11-01T01:18:11.609Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->23.8)
2025-11-01T01:18:11.687Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.8% (14.3 A)
2025-11-01T01:18:23.593Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-01T01:18:23.609Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.6)
2025-11-01T01:18:35.593Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-01T01:18:47.593Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-01T01:18:55.585Z:INFO:active_lb.c:308:SMt:(14.0 15.0 14.0)A Free:(2.0 1.0 2.0)A ALB:(15.6 14.7 15.2)A
2025-11-01T01:18:59.589Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:19:11.589Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->13.2 due to current limit: Active-LoadBalancing
2025-11-01T01:19:11.601Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->22.0)
2025-11-01T01:19:12.281Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.0% (13.2 A)
2025-11-01T01:19:23.589Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->11.1 due to current limit: Active-LoadBalancing
2025-11-01T01:19:23.601Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.0->18.5)
2025-11-01T01:19:24.398Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.5% (11.1 A)
2025-11-01T01:19:35.589Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->9.4 due to current limit: Active-LoadBalancing
2025-11-01T01:19:35.601Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->15.6)
2025-11-01T01:19:36.519Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.6% (9.4 A)
2025-11-01T01:19:47.585Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->8.4 due to current limit: Active-LoadBalancing
2025-11-01T01:19:47.597Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.6->14.0)
2025-11-01T01:19:47.625Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.0% (8.4 A)
2025-11-01T01:19:59.585Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->7.5 due to current limit: Active-LoadBalancing
2025-11-01T01:19:59.597Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.0->12.4)
2025-11-01T01:19:59.746Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.4% (7.4 A)
2025-11-01T01:20:11.585Z:INFO:taskMain.c:5996:Socket #1: Active current 7.5->7.4 due to current limit: Active-LoadBalancing
2025-11-01T01:20:11.597Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (12.4->12.2)
2025-11-01T01:20:23.582Z:INFO:taskMain.c:5996:Socket #1: Active current 7.4->7.6 due to current limit: Active-LoadBalancing
2025-11-01T01:20:35.582Z:INFO:taskMain.c:5996:Socket #1: Active current 7.6->8.2 due to current limit: Active-LoadBalancing
2025-11-01T01:20:36.101Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.7% (8.2 A)
2025-11-01T01:20:47.582Z:INFO:taskMain.c:5996:Socket #1: Active current 8.2->8.9 due to current limit: Active-LoadBalancing
2025-11-01T01:20:48.218Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.8% (8.9 A)
2025-11-01T01:20:59.578Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->9.6 due to current limit: Active-LoadBalancing
2025-11-01T01:21:00.339Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.9% (9.5 A)
2025-11-01T01:21:11.578Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->9.8 due to current limit: Active-LoadBalancing
2025-11-01T01:21:23.578Z:INFO:taskMain.c:5996:Socket #1: Active current 9.8->10.0 due to current limit: Active-LoadBalancing
2025-11-01T01:21:35.574Z:INFO:taskMain.c:5996:Socket #1: Active current 10.0->9.5 due to current limit: Active-LoadBalancing
2025-11-01T01:21:35.585Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (16.7->15.8)
2025-11-01T01:21:35.683Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.8% (9.5 A)
2025-11-01T01:21:47.574Z:INFO:taskMain.c:5996:Socket #1: Active current 9.5->8.5 due to current limit: Active-LoadBalancing
2025-11-01T01:21:47.585Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.8->14.1)
2025-11-01T01:21:47.804Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.1% (8.5 A)
2025-11-01T01:21:59.574Z:INFO:taskMain.c:5996:Socket #1: Active current 8.5->7.5 due to current limit: Active-LoadBalancing
2025-11-01T01:21:59.585Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.1->12.5)
2025-11-01T01:21:59.921Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.5% (7.5 A)
2025-11-01T01:22:11.570Z:INFO:taskMain.c:5996:Socket #1: Active current 7.5->7.0 due to current limit: Active-LoadBalancing
2025-11-01T01:22:11.582Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (12.5->11.6)
2025-11-01T01:22:12.042Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.6% (7.0 A)
2025-11-01T01:22:23.570Z:INFO:taskMain.c:5996:Socket #1: Active current 7.0->6.9 due to current limit: Active-LoadBalancing
2025-11-01T01:22:23.582Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.6->11.4)
2025-11-01T01:22:35.570Z:INFO:taskMain.c:5996:Socket #1: Active current 6.9->7.1 due to current limit: Active-LoadBalancing
2025-11-01T01:22:41.511Z:USER:taskMaster.c:6684:Socket #1: L1N=235.3V L2N=236.5V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T01:22:41.523Z:USER:taskMaster.c:6720:Socket #1: I1=6.7A I2=6.8A I3=6.6A P=4.7kW Idc=0.7mA
2025-11-01T01:22:47.566Z:INFO:taskMain.c:5996:Socket #1: Active current 7.1->7.3 due to current limit: Active-LoadBalancing
2025-11-01T01:22:59.566Z:INFO:taskMain.c:5996:Socket #1: Active current 7.3->7.6 due to current limit: Active-LoadBalancing
2025-11-01T01:23:11.566Z:INFO:taskMain.c:5996:Socket #1: Active current 7.6->7.8 due to current limit: Active-LoadBalancing
2025-11-01T01:23:23.562Z:INFO:taskMain.c:5996:Socket #1: Active current 7.8->8.5 due to current limit: Active-LoadBalancing
2025-11-01T01:23:23.742Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.1% (8.5 A)
2025-11-01T01:23:35.562Z:INFO:taskMain.c:5996:Socket #1: Active current 8.5->9.1 due to current limit: Active-LoadBalancing
2025-11-01T01:23:35.863Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.1% (9.1 A)
2025-11-01T01:23:47.562Z:INFO:taskMain.c:5996:Socket #1: Active current 9.1->9.3 due to current limit: Active-LoadBalancing
2025-11-01T01:23:56.156Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-01T01:23:59.558Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->9.6 due to current limit: Active-LoadBalancing
2025-11-01T01:24:11.558Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->9.5 due to current limit: Active-LoadBalancing
2025-11-01T01:24:11.570Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (16.0->15.8)
2025-11-01T01:24:23.558Z:INFO:taskMain.c:5996:Socket #1: Active current 9.5->9.3 due to current limit: Active-LoadBalancing
2025-11-01T01:24:23.570Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.8->15.5)
2025-11-01T01:24:35.554Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->9.2 due to current limit: Active-LoadBalancing
2025-11-01T01:24:35.570Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.5->15.3)
2025-11-01T01:24:47.554Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->9.1 due to current limit: Active-LoadBalancing
2025-11-01T01:24:47.566Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.3->15.1)
2025-11-01T01:24:59.554Z:INFO:taskMain.c:5996:Socket #1: Active current 9.1->8.9 due to current limit: Active-LoadBalancing
2025-11-01T01:24:59.566Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.1->14.8)
2025-11-01T01:25:11.550Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.8 due to current limit: Active-LoadBalancing
2025-11-01T01:25:11.566Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.8->14.6)
2025-11-01T01:25:23.550Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->8.6 due to current limit: Active-LoadBalancing
2025-11-01T01:25:23.562Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.6->14.3)
2025-11-01T01:25:35.550Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.9 due to current limit: Active-LoadBalancing
2025-11-01T01:25:38.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T01:25:47.546Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->9.1 due to current limit: Active-LoadBalancing
2025-11-01T01:25:59.546Z:INFO:taskMain.c:5996:Socket #1: Active current 9.1->9.4 due to current limit: Active-LoadBalancing
2025-11-01T01:26:11.546Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->9.3 due to current limit: Active-LoadBalancing
2025-11-01T01:26:11.558Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.7->15.4)
2025-11-01T01:26:23.542Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->9.1 due to current limit: Active-LoadBalancing
2025-11-01T01:26:23.558Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.4->15.1)
2025-11-01T01:26:35.542Z:INFO:taskMain.c:5996:Socket #1: Active current 9.1->8.9 due to current limit: Active-LoadBalancing
2025-11-01T01:26:35.554Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.1->14.8)
2025-11-01T01:26:47.542Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.8 due to current limit: Active-LoadBalancing
2025-11-01T01:26:47.554Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.8->14.6)
2025-11-01T01:26:59.542Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->8.6 due to current limit: Active-LoadBalancing
2025-11-01T01:26:59.554Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.6->14.3)
2025-11-01T01:27:11.539Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.5 due to current limit: Active-LoadBalancing
2025-11-01T01:27:11.550Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.3->14.0)
2025-11-01T01:27:23.539Z:INFO:taskMain.c:5996:Socket #1: Active current 8.5->8.7 due to current limit: Active-LoadBalancing
2025-11-01T01:27:35.539Z:INFO:taskMain.c:5996:Socket #1: Active current 8.7->9.0 due to current limit: Active-LoadBalancing
2025-11-01T01:27:47.535Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->9.2 due to current limit: Active-LoadBalancing
2025-11-01T01:27:59.535Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->9.5 due to current limit: Active-LoadBalancing
2025-11-01T01:28:11.535Z:INFO:taskMain.c:5996:Socket #1: Active current 9.5->9.3 due to current limit: Active-LoadBalancing
2025-11-01T01:28:11.546Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.7->15.5)
2025-11-01T01:28:23.531Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->9.2 due to current limit: Active-LoadBalancing
2025-11-01T01:28:23.542Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.5->15.3)
2025-11-01T01:28:35.531Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->9.1 due to current limit: Active-LoadBalancing
2025-11-01T01:28:35.542Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.3->15.0)
2025-11-01T01:28:47.531Z:INFO:taskMain.c:5996:Socket #1: Active current 9.1->8.9 due to current limit: Active-LoadBalancing
2025-11-01T01:28:47.542Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.0->14.8)
2025-11-01T01:28:55.523Z:INFO:active_lb.c:308:SMt:(16.0 10.0 9.0)A Free:(0.0 6.0 7.0)A ALB:(8.9 14.9 15.0)A
2025-11-01T01:28:59.527Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.8 due to current limit: Active-LoadBalancing
2025-11-01T01:28:59.539Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.8->14.5)
2025-11-01T01:29:11.527Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->8.6 due to current limit: Active-LoadBalancing
2025-11-01T01:29:11.539Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.5->14.3)
2025-11-01T01:29:23.527Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.9 due to current limit: Active-LoadBalancing
2025-11-01T01:29:35.523Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.7 due to current limit: Active-LoadBalancing
2025-11-01T01:29:35.535Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.7->14.5)
2025-11-01T01:29:47.523Z:INFO:taskMain.c:5996:Socket #1: Active current 8.7->11.4 due to current limit: Active-LoadBalancing
2025-11-01T01:29:48.523Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.9% (11.3 A)
2025-11-01T01:29:59.523Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->14.0 due to current limit: Active-LoadBalancing
2025-11-01T01:29:59.632Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.3% (14.0 A)
2025-11-01T01:30:11.519Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->15.4 due to current limit: Active-LoadBalancing
2025-11-01T01:30:11.750Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.6% (15.4 A)
2025-11-01T01:30:23.519Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.9 due to current limit: ChargingProfile
2025-11-01T01:30:23.562Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-01T01:30:23.871Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-01T01:30:35.519Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.7 due to current limit: Active-LoadBalancing
2025-11-01T01:30:35.531Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->26.0)
2025-11-01T01:30:35.562Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T01:30:47.515Z:INFO:taskMain.c:5996:Socket #1: Active current 15.7->15.1 due to current limit: Active-LoadBalancing
2025-11-01T01:30:47.531Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.0->25.1)
2025-11-01T01:30:48.105Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.1% (15.1 A)
2025-11-01T01:30:59.515Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:30:59.527Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-01T01:31:11.515Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:31:11.527Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-01T01:31:23.511Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:31:23.527Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-01T01:31:35.511Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:31:47.511Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-01T01:31:59.507Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-01T01:31:59.523Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-01T01:32:11.507Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:32:11.519Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-01T01:32:23.507Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:32:23.519Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-01T01:32:35.503Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:32:47.503Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T01:32:47.515Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-01T01:32:59.503Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:32:59.515Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T01:33:11.500Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:33:23.500Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-01T01:33:23.511Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-01T01:33:35.500Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.2 due to current limit: Active-LoadBalancing
2025-11-01T01:33:35.511Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->23.5)
2025-11-01T01:33:35.750Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.5% (14.1 A)
2025-11-01T01:33:47.496Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.0 due to current limit: Active-LoadBalancing
2025-11-01T01:33:47.511Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.5->23.2)
2025-11-01T01:33:59.496Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.8 due to current limit: Active-LoadBalancing
2025-11-01T01:33:59.507Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.2->22.9)
2025-11-01T01:34:11.496Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.6 due to current limit: Active-LoadBalancing
2025-11-01T01:34:11.507Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.9->22.6)
2025-11-01T01:34:23.496Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-01T01:34:23.507Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.6->22.4)
2025-11-01T01:34:35.492Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.3 due to current limit: Active-LoadBalancing
2025-11-01T01:34:35.503Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.4->22.1)
2025-11-01T01:34:47.492Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.9 due to current limit: Active-LoadBalancing
2025-11-01T01:34:48.460Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.1% (13.9 A)
2025-11-01T01:34:59.492Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:34:59.570Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-01T01:35:11.488Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->15.2 due to current limit: Active-LoadBalancing
2025-11-01T01:35:11.687Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.3% (15.2 A)
2025-11-01T01:35:23.488Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.4 due to current limit: Active-LoadBalancing
2025-11-01T01:35:35.488Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.3 due to current limit: Active-LoadBalancing
2025-11-01T01:35:35.500Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.6->25.4)
2025-11-01T01:35:47.484Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-01T01:35:47.496Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-01T01:35:59.484Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:35:59.496Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-01T01:36:11.484Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:36:11.496Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-01T01:36:23.480Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:36:23.496Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-01T01:36:35.480Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:36:47.480Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-01T01:36:59.476Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:36:59.492Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-01T01:37:11.476Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:37:11.488Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-01T01:37:23.476Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:37:23.488Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-01T01:37:35.472Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:37:41.417Z:USER:taskMaster.c:6684:Socket #1: L1N=235.7V L2N=236.2V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T01:37:41.429Z:USER:taskMaster.c:6720:Socket #1: I1=14.4A I2=14.5A I3=14.5A P=10.3kW Idc=0.7mA
2025-11-01T01:37:47.472Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-01T01:37:59.472Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:37:59.484Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-01T01:38:11.468Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:38:11.484Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-01T01:38:23.468Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:38:23.480Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-01T01:38:35.468Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:38:47.464Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-01T01:38:55.460Z:INFO:active_lb.c:308:SMt:(15.0 15.0 15.0)A Free:(1.0 1.0 1.0)A ALB:(15.3 15.1 15.4)A
2025-11-01T01:38:56.511Z:USER:taskMaster.c:6582:Temperature: 26.8 C
2025-11-01T01:38:59.464Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-01T01:38:59.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-01T01:39:11.464Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:39:11.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-01T01:39:23.460Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:39:23.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-01T01:39:35.460Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:39:47.460Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-01T01:39:59.457Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-01T01:39:59.472Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-01T01:40:11.457Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:40:11.468Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-01T01:40:23.457Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-01T01:40:23.468Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-01T01:40:35.453Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-01T01:40:35.468Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-01T01:40:38.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T01:40:47.453Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:40:59.453Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-01T01:41:11.449Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-01T01:41:23.449Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.2 due to current limit: Active-LoadBalancing
2025-11-01T01:41:23.460Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->25.2)
2025-11-01T01:41:35.449Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-01T01:41:35.460Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-01T01:41:47.449Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:41:47.460Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-01T01:41:59.445Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-01T01:41:59.457Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-01T01:42:11.445Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-01T01:42:11.457Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-01T01:42:23.445Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:42:35.441Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-01T01:42:47.441Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:42:47.453Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-01T01:42:59.441Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T01:42:59.453Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T01:43:11.437Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:43:11.449Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T01:43:23.437Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:43:35.437Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-01T01:43:47.433Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:43:47.449Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-01T01:43:59.433Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T01:43:59.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T01:44:11.433Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:44:11.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T01:44:23.429Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:44:35.429Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-01T01:44:47.429Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:44:47.441Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-01T01:44:59.425Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:44:59.441Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T01:45:11.425Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:45:11.437Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T01:45:23.425Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:45:35.421Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-01T01:45:47.421Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:45:47.433Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-01T01:45:59.421Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:45:59.433Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-01T01:46:11.417Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:46:11.433Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-01T01:46:23.417Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:46:35.417Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-01T01:46:47.414Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:46:47.429Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-01T01:46:59.414Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:46:59.425Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-01T01:47:11.414Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:47:11.425Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-01T01:47:23.410Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:47:35.410Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-01T01:47:47.410Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:47:47.421Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-01T01:47:59.406Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:47:59.421Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-01T01:48:11.406Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:48:11.417Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-01T01:48:23.406Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:48:35.406Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-01T01:48:47.402Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:48:47.414Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-01T01:48:55.394Z:INFO:active_lb.c:308:SMt:(15.0 16.0 15.0)A Free:(1.0 0.0 1.0)A ALB:(15.5 14.9 15.5)A
2025-11-01T01:48:59.402Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:48:59.414Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-01T01:49:11.402Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->13.4 due to current limit: Active-LoadBalancing
2025-11-01T01:49:11.414Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->22.4)
2025-11-01T01:49:11.921Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-01T01:49:23.398Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.3 due to current limit: Active-LoadBalancing
2025-11-01T01:49:23.410Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.4->22.1)
2025-11-01T01:49:35.398Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.6 due to current limit: Active-LoadBalancing
2025-11-01T01:49:47.398Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->14.2 due to current limit: Active-LoadBalancing
2025-11-01T01:49:48.277Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.6% (14.2 A)
2025-11-01T01:49:59.394Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-01T01:50:11.394Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-01T01:50:23.394Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-01T01:50:35.390Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:50:35.406Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-01T01:50:47.390Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-01T01:50:47.402Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-01T01:50:59.390Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-01T01:50:59.402Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-01T01:51:11.386Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-01T01:51:11.402Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.9)
2025-11-01T01:51:23.386Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:51:35.386Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:51:47.382Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-01T01:51:47.398Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-01T01:51:59.382Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-01T01:51:59.394Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-01T01:52:11.382Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-01T01:52:11.394Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.9)
2025-11-01T01:52:23.378Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:52:35.378Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:52:41.324Z:USER:taskMaster.c:6684:Socket #1: L1N=235.8V L2N=235.9V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T01:52:41.335Z:USER:taskMaster.c:6720:Socket #1: I1=14.4A I2=14.4A I3=14.4A P=10.2kW Idc=0.7mA
2025-11-01T01:52:47.378Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-01T01:52:47.390Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-01T01:52:59.375Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-01T01:52:59.390Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-01T01:53:11.375Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-01T01:53:11.386Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-01T01:53:23.375Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-01T01:53:35.371Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:53:47.371Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:53:47.382Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-01T01:53:56.914Z:USER:taskMaster.c:6582:Temperature: 28.5 C
2025-11-01T01:53:59.371Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-01T01:53:59.382Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-01T01:54:11.367Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-01T01:54:11.382Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-01T01:54:23.367Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:54:35.367Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:54:47.363Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:54:47.378Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-01T01:54:59.363Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-01T01:54:59.375Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-01T01:55:11.363Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-01T01:55:11.375Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.9)
2025-11-01T01:55:23.359Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-01T01:55:23.375Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.6)
2025-11-01T01:55:35.359Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-01T01:55:38.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T01:55:47.359Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-01T01:55:59.359Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-01T01:56:11.355Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:56:11.367Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-01T01:56:23.355Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-01T01:56:23.367Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-01T01:56:35.355Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-01T01:56:35.367Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-01T01:56:47.351Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-01T01:56:47.363Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-01T01:56:59.351Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-01T01:56:59.363Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.6)
2025-11-01T01:57:11.351Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-01T01:57:23.347Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-01T01:57:35.347Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-01T01:57:35.359Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-01T01:57:47.347Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-01T01:57:47.359Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-01T01:57:59.343Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-01T01:58:11.343Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-01T01:58:23.343Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-01T01:58:35.339Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-01T01:58:47.339Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T01:58:47.351Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-01T01:58:55.332Z:INFO:active_lb.c:308:SMt:(15.0 16.0 15.0)A Free:(1.0 0.0 1.0)A ALB:(15.3 14.7 15.4)A
2025-11-01T01:58:59.339Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:58:59.351Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-01T01:59:11.335Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T01:59:11.351Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->24.0)
2025-11-01T01:59:23.335Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-01T01:59:23.347Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-01T01:59:35.335Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-01T01:59:47.332Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-01T01:59:59.332Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T01:59:59.343Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-01T02:00:11.332Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-01T02:00:11.343Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-01T02:00:22.777Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-01T02:00:22.785Z:INFO:db_chargingprofi:26: socket 0
2025-11-01T02:00:22.792Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-01T02:00:22.804Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-01T02:00:22.808Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-01T02:00:22.820Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-01T02:00:22.832Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-01T02:00:22.839Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-01T02:00:22.847Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-01T02:00:22.855Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-01T02:00:22.863Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-01T02:00:22.871Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-01T02:00:22.878Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-01T02:00:22.886Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-01T02:00:22.894Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-01T02:00:22.906Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-01T02:00:22.914Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-01T02:00:22.921Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-01T02:00:22.933Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-01T02:00:22.941Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-01T02:00:22.949Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-01T02:00:22.957Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-01T02:00:22.964Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-01T02:00:23.328Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-01T02:00:23.343Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-01T02:00:35.328Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-01T02:00:47.328Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:00:59.324Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:00:59.339Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-01T02:01:11.324Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-01T02:01:11.335Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-01T02:01:23.324Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-01T02:01:23.335Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-01T02:01:35.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-01T02:01:47.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:01:59.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:01:59.332Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-01T02:02:11.316Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-01T02:02:11.332Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-01T02:02:23.316Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-01T02:02:23.328Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-01T02:02:35.316Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-01T02:02:47.312Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:02:59.312Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->12.5 due to current limit: Active-LoadBalancing
2025-11-01T02:02:59.324Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->20.8)
2025-11-01T02:03:00.023Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-01T02:03:11.312Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->9.5 due to current limit: Active-LoadBalancing
2025-11-01T02:03:11.324Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.8->15.8)
2025-11-01T02:03:12.140Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.8% (9.5 A)
2025-11-01T02:03:23.312Z:INFO:taskMain.c:5996:Socket #1: Active current 9.5->7.3 due to current limit: Active-LoadBalancing
2025-11-01T02:03:23.324Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.8->12.2)
2025-11-01T02:03:24.261Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.2% (7.3 A)
2025-11-01T02:03:35.308Z:INFO:taskMain.c:5996:Socket #1: Active current 7.3->6.4 due to current limit: Active-LoadBalancing
2025-11-01T02:03:35.320Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (12.2->10.6)
2025-11-01T02:03:35.371Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.6% (6.4 A)
2025-11-01T02:03:47.308Z:INFO:taskMain.c:5996:Socket #1: Active current 6.4->6.2 due to current limit: Active-LoadBalancing
2025-11-01T02:03:47.320Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (10.6->10.3)
2025-11-01T02:03:59.308Z:INFO:taskMain.c:5996:Socket #1: Active current 6.2->6.6 due to current limit: Active-LoadBalancing
2025-11-01T02:03:59.605Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.9% (6.5 A)
2025-11-01T02:04:11.304Z:INFO:taskMain.c:5996:Socket #1: Active current 6.6->6.8 due to current limit: Active-LoadBalancing
2025-11-01T02:04:23.304Z:INFO:taskMain.c:5996:Socket #1: Active current 6.8->7.0 due to current limit: Active-LoadBalancing
2025-11-01T02:04:35.304Z:INFO:taskMain.c:5996:Socket #1: Active current 7.0->7.3 due to current limit: Active-LoadBalancing
2025-11-01T02:04:47.300Z:INFO:taskMain.c:5996:Socket #1: Active current 7.3->7.2 due to current limit: Active-LoadBalancing
2025-11-01T02:04:47.312Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (12.1->11.9)
2025-11-01T02:04:59.300Z:INFO:taskMain.c:5996:Socket #1: Active current 7.2->6.6 due to current limit: Active-LoadBalancing
2025-11-01T02:04:59.312Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.9->11.0)
2025-11-01T02:05:00.199Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.0% (6.6 A)
2025-11-01T02:05:11.300Z:INFO:taskMain.c:5996:Socket #1: Active current 6.6->9.7 due to current limit: Active-LoadBalancing
2025-11-01T02:05:11.312Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.1% (9.7 A)
2025-11-01T02:05:23.296Z:INFO:taskMain.c:5996:Socket #1: Active current 9.7->12.7 due to current limit: Active-LoadBalancing
2025-11-01T02:05:23.429Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.2% (12.7 A)
2025-11-01T02:05:35.296Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:05:35.546Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-01T02:05:47.296Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->15.2 due to current limit: Active-LoadBalancing
2025-11-01T02:05:47.664Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.3% (15.2 A)
2025-11-01T02:05:59.292Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.4 due to current limit: Active-LoadBalancing
2025-11-01T02:06:11.292Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.2 due to current limit: Active-LoadBalancing
2025-11-01T02:06:11.304Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->25.4)
2025-11-01T02:06:23.292Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.1 due to current limit: Active-LoadBalancing
2025-11-01T02:06:23.304Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-01T02:06:35.289Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:06:35.304Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-01T02:06:47.289Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:06:47.300Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T02:06:59.289Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:06:59.300Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-01T02:07:11.285Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T02:07:11.300Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-01T02:07:23.285Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-01T02:07:23.296Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.7)
2025-11-01T02:07:35.285Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-01T02:07:41.226Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=232.6V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T02:07:41.238Z:USER:taskMaster.c:6720:Socket #1: I1=14.0A I2=14.1A I3=14.0A P=9.8kW Idc=0.7mA
2025-11-01T02:07:47.281Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:07:59.281Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:08:11.281Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-01T02:08:23.277Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:08:23.292Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-01T02:08:35.277Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:08:35.289Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-01T02:08:47.277Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:08:47.289Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T02:08:55.269Z:INFO:active_lb.c:308:SMt:(16.0 16.0 15.0)A Free:(0.0 0.0 1.0)A ALB:(14.7 14.7 15.5)A
2025-11-01T02:08:57.320Z:USER:taskMaster.c:6582:Temperature: 29.6 C
2025-11-01T02:08:59.273Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:08:59.289Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-01T02:09:11.273Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T02:09:11.285Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-01T02:09:23.273Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-01T02:09:23.285Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.6)
2025-11-01T02:09:35.269Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-01T02:09:47.269Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:09:48.011Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.9% (14.9 A)
2025-11-01T02:09:59.269Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.2 due to current limit: Active-LoadBalancing
2025-11-01T02:10:11.265Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:10:11.281Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-01T02:10:23.265Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:10:23.277Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-01T02:10:35.265Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:10:35.277Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T02:10:38.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T02:10:47.261Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:10:47.277Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T02:10:59.261Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T02:10:59.273Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-01T02:11:11.261Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:11:23.261Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:11:35.257Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-01T02:11:47.257Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:11:47.269Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-01T02:11:59.257Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:11:59.269Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-01T02:12:11.253Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:12:11.265Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-01T02:12:23.253Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-01T02:12:23.265Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-01T02:12:35.253Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:12:47.250Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->12.1 due to current limit: Active-LoadBalancing
2025-11-01T02:12:47.265Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->20.1)
2025-11-01T02:12:47.769Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.1% (12.1 A)
2025-11-01T02:12:59.250Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->9.1 due to current limit: Active-LoadBalancing
2025-11-01T02:12:59.261Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.1->15.2)
2025-11-01T02:12:59.890Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.2% (9.1 A)
2025-11-01T02:13:11.250Z:INFO:taskMain.c:5996:Socket #1: Active current 9.1->7.0 due to current limit: Active-LoadBalancing
2025-11-01T02:13:11.261Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.2->11.6)
2025-11-01T02:13:12.007Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.6% (7.0 A)
2025-11-01T02:13:23.246Z:INFO:taskMain.c:5996:Socket #1: Active current 7.0->6.1 due to current limit: Active-LoadBalancing
2025-11-01T02:13:23.257Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.6->10.1)
2025-11-01T02:13:24.128Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.1% (6.1 A)
2025-11-01T02:13:35.246Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (10.1->10.0)
2025-11-01T02:13:47.246Z:INFO:taskMain.c:5996:Socket #1: Active current 6.1->6.4 due to current limit: Active-LoadBalancing
2025-11-01T02:13:47.355Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.7% (6.4 A)
2025-11-01T02:13:59.242Z:INFO:taskMain.c:5996:Socket #1: Active current 6.4->6.7 due to current limit: Active-LoadBalancing
2025-11-01T02:14:11.242Z:INFO:taskMain.c:5996:Socket #1: Active current 6.7->6.9 due to current limit: Active-LoadBalancing
2025-11-01T02:14:23.242Z:INFO:taskMain.c:5996:Socket #1: Active current 6.9->7.2 due to current limit: Active-LoadBalancing
2025-11-01T02:14:35.238Z:INFO:taskMain.c:5996:Socket #1: Active current 7.2->7.1 due to current limit: Active-LoadBalancing
2025-11-01T02:14:35.253Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (12.0->11.7)
2025-11-01T02:14:47.238Z:INFO:taskMain.c:5996:Socket #1: Active current 7.1->6.9 due to current limit: Active-LoadBalancing
2025-11-01T02:14:47.250Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.7->11.5)
2025-11-01T02:14:59.238Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.5->11.3)
2025-11-01T02:15:11.234Z:INFO:taskMain.c:5996:Socket #1: Active current 6.8->6.6 due to current limit: Active-LoadBalancing
2025-11-01T02:15:11.250Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.3->11.0)
2025-11-01T02:15:23.234Z:INFO:taskMain.c:5996:Socket #1: Active current 6.6->6.9 due to current limit: Active-LoadBalancing
2025-11-01T02:15:35.234Z:INFO:taskMain.c:5996:Socket #1: Active current 6.9->7.2 due to current limit: Active-LoadBalancing
2025-11-01T02:15:47.230Z:INFO:taskMain.c:5996:Socket #1: Active current 7.2->7.1 due to current limit: Active-LoadBalancing
2025-11-01T02:15:47.246Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (12.0->11.8)
2025-11-01T02:15:59.230Z:INFO:taskMain.c:5996:Socket #1: Active current 7.1->6.9 due to current limit: Active-LoadBalancing
2025-11-01T02:15:59.242Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.8->11.5)
2025-11-01T02:16:11.230Z:INFO:taskMain.c:5996:Socket #1: Active current 6.9->6.8 due to current limit: Active-LoadBalancing
2025-11-01T02:16:11.242Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.5->11.3)
2025-11-01T02:16:23.226Z:INFO:taskMain.c:5996:Socket #1: Active current 6.8->6.6 due to current limit: Active-LoadBalancing
2025-11-01T02:16:23.242Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.3->11.0)
2025-11-01T02:16:35.226Z:INFO:taskMain.c:5996:Socket #1: Active current 6.6->6.9 due to current limit: Active-LoadBalancing
2025-11-01T02:16:47.226Z:INFO:taskMain.c:5996:Socket #1: Active current 6.9->7.2 due to current limit: Active-LoadBalancing
2025-11-01T02:16:59.222Z:INFO:taskMain.c:5996:Socket #1: Active current 7.2->10.7 due to current limit: Active-LoadBalancing
2025-11-01T02:16:59.238Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.8% (10.7 A)
2025-11-01T02:17:11.222Z:INFO:taskMain.c:5996:Socket #1: Active current 10.7->14.1 due to current limit: Active-LoadBalancing
2025-11-01T02:17:11.351Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.5% (14.1 A)
2025-11-01T02:17:23.222Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->15.9 due to current limit: ChargingProfile
2025-11-01T02:17:23.265Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-01T02:17:23.472Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-01T02:17:59.218Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.5 due to current limit: Active-LoadBalancing
2025-11-01T02:17:59.230Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->25.7)
2025-11-01T02:17:59.261Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T02:17:59.828Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.7% (15.4 A)
2025-11-01T02:18:11.214Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:18:11.230Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->24.8)
2025-11-01T02:18:11.945Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.8% (14.9 A)
2025-11-01T02:18:23.214Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:18:23.226Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T02:18:35.214Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:18:35.226Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T02:18:47.214Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:18:55.257Z:INFO:active_lb.c:308:SMt:(15.0 15.0 15.0)A Free:(1.0 1.0 1.0)A ALB:(15.3 14.9 15.3)A
2025-11-01T02:18:59.210Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-01T02:19:11.210Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:19:11.222Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-01T02:19:23.210Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:19:23.222Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-01T02:19:35.207Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:19:35.218Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-01T02:19:47.207Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-01T02:19:47.218Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-01T02:20:11.203Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:20:23.203Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:20:35.203Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:20:35.214Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-01T02:20:47.199Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:20:47.214Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.4)
2025-11-01T02:20:59.199Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-01T02:20:59.210Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-01T02:21:11.199Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-01T02:21:11.210Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-01T02:21:23.195Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-01T02:21:35.195Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:21:47.195Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:21:59.191Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.4 due to current limit: Active-LoadBalancing
2025-11-01T02:22:00.183Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.6% (15.4 A)
2025-11-01T02:22:11.191Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.2 due to current limit: Active-LoadBalancing
2025-11-01T02:22:11.203Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.6->25.3)
2025-11-01T02:22:23.191Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:22:23.203Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-01T02:22:35.187Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:22:35.203Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-01T02:22:41.132Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=233.0V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T02:22:41.144Z:USER:taskMaster.c:6720:Socket #1: I1=14.4A I2=14.4A I3=14.4A P=10.0kW Idc=0.7mA
2025-11-01T02:22:47.187Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:22:47.199Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T02:22:59.187Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:22:59.199Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T02:23:11.183Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T02:23:11.199Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-01T02:23:23.183Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-01T02:23:23.195Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.7)
2025-11-01T02:23:35.183Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-01T02:23:47.179Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:23:47.230Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.8% (14.9 A)
2025-11-01T02:23:57.675Z:USER:taskMaster.c:6582:Temperature: 30.0 C
2025-11-01T02:23:59.179Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-01T02:24:11.179Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.4 due to current limit: Active-LoadBalancing
2025-11-01T02:24:23.175Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.2 due to current limit: Active-LoadBalancing
2025-11-01T02:24:23.191Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.6->25.3)
2025-11-01T02:24:35.175Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.1 due to current limit: Active-LoadBalancing
2025-11-01T02:24:35.187Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-01T02:24:47.175Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:24:47.187Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-01T02:24:59.171Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:24:59.187Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T02:25:11.171Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:25:11.183Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T02:25:23.171Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:25:35.167Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-01T02:25:38.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T02:25:47.167Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:25:47.179Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-01T02:25:59.167Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:25:59.179Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-01T02:26:11.164Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:26:11.179Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-01T02:26:23.164Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:26:35.164Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-01T02:26:47.164Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:26:47.175Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-01T02:26:59.160Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:26:59.171Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-01T02:27:11.160Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:27:11.171Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-01T02:27:23.160Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-01T02:27:23.171Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-01T02:27:35.156Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:27:47.156Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:27:59.156Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-01T02:28:11.152Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.5 due to current limit: Active-LoadBalancing
2025-11-01T02:28:23.152Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.3 due to current limit: Active-LoadBalancing
2025-11-01T02:28:23.164Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.8->25.5)
2025-11-01T02:28:35.152Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.2 due to current limit: Active-LoadBalancing
2025-11-01T02:28:35.164Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->25.3)
2025-11-01T02:28:47.148Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:28:47.160Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-01T02:28:55.191Z:INFO:active_lb.c:308:SMt:(15.0 16.0 15.0)A Free:(1.0 0.0 1.0)A ALB:(15.9 15.0 15.0)A
2025-11-01T02:28:59.148Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:28:59.160Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-01T02:29:11.148Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:29:11.160Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T02:29:23.144Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:29:23.160Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T02:29:35.144Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T02:29:35.156Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-01T02:29:47.144Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:29:59.140Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:30:11.140Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-01T02:30:23.140Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:30:23.152Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-01T02:30:35.136Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:30:35.152Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-01T02:30:47.136Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:30:47.148Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-01T02:30:59.136Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-01T02:30:59.148Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-01T02:31:11.132Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-01T02:31:11.148Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-01T02:31:23.132Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-01T02:31:35.132Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:31:47.128Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:31:59.128Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-01T02:32:11.128Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.5 due to current limit: Active-LoadBalancing
2025-11-01T02:32:23.125Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.3 due to current limit: Active-LoadBalancing
2025-11-01T02:32:23.140Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.8->25.5)
2025-11-01T02:32:35.125Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.2 due to current limit: Active-LoadBalancing
2025-11-01T02:32:35.136Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->25.3)
2025-11-01T02:32:47.125Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:32:47.136Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-01T02:32:59.121Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:32:59.136Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-01T02:33:11.121Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:33:11.132Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T02:33:23.121Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:33:23.132Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-01T02:33:35.117Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:33:47.117Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:33:59.117Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-01T02:34:11.113Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.5 due to current limit: Active-LoadBalancing
2025-11-01T02:34:23.113Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.3 due to current limit: Active-LoadBalancing
2025-11-01T02:34:23.125Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.8->25.5)
2025-11-01T02:34:35.113Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.2 due to current limit: Active-LoadBalancing
2025-11-01T02:34:35.125Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->25.2)
2025-11-01T02:34:47.113Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:34:47.125Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->25.0)
2025-11-01T02:34:59.109Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:34:59.121Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-01T02:35:11.109Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:35:11.121Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T02:35:23.109Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:35:23.121Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-01T02:35:35.105Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T02:35:35.117Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-01T02:35:47.105Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:35:59.105Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:36:11.101Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:36:23.101Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-01T02:36:35.101Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.2)
2025-11-01T02:36:47.097Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:36:47.109Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-01T02:36:59.097Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:36:59.109Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-01T02:37:11.097Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:37:11.109Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-01T02:37:23.093Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-01T02:37:23.109Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-01T02:37:35.093Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:37:41.035Z:USER:taskMaster.c:6684:Socket #1: L1N=233.2V L2N=233.5V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T02:37:41.050Z:USER:taskMaster.c:6720:Socket #1: I1=14.3A I2=14.4A I3=14.3A P=10.0kW Idc=0.7mA
2025-11-01T02:37:47.093Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:37:59.089Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-01T02:38:11.089Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.5 due to current limit: Active-LoadBalancing
2025-11-01T02:38:23.089Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.3 due to current limit: Active-LoadBalancing
2025-11-01T02:38:23.101Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.8->25.5)
2025-11-01T02:38:35.085Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.2 due to current limit: Active-LoadBalancing
2025-11-01T02:38:35.101Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->25.3)
2025-11-01T02:38:46.980Z:INFO:heap_trace.c:493:free: 69416/160768 (43.2%) min: 43808 (27.2%) alloc #: 197
2025-11-01T02:38:46.992Z:INFO:heap_trace.c:495:fragm: 28.6% 4K: 11.5% free blocks: # 11 largest: 49560
2025-11-01T02:38:47.085Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:38:47.097Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-01T02:38:55.128Z:INFO:active_lb.c:308:SMt:(15.0 16.0 16.0)A Free:(1.0 0.0 0.0)A ALB:(15.9 15.0 15.0)A
2025-11-01T02:38:58.078Z:USER:taskMaster.c:6582:Temperature: 30.5 C
2025-11-01T02:38:59.085Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:38:59.097Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.7)
2025-11-01T02:39:11.082Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:39:11.097Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-01T02:39:23.082Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:39:23.093Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T02:39:35.082Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:39:45.816Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-01T02:39:46.117Z:INFO:taskCANopen.c:1787:Updated object 0x2249, 9 bytes
2025-11-01T02:39:47.078Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-01T02:39:59.078Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.3 due to current limit: Active-LoadBalancing
2025-11-01T02:40:11.078Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.2 due to current limit: Active-LoadBalancing
2025-11-01T02:40:11.089Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->25.3)
2025-11-01T02:40:23.074Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:40:23.089Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-01T02:40:35.074Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:40:35.085Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-01T02:40:38.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T02:40:47.074Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:40:47.085Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T02:40:59.070Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:40:59.085Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T02:41:11.070Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T02:41:11.082Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-01T02:41:23.070Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:41:35.066Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:41:47.066Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.2 due to current limit: Active-LoadBalancing
2025-11-01T02:41:59.066Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.4 due to current limit: Active-LoadBalancing
2025-11-01T02:42:11.062Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.2 due to current limit: Active-LoadBalancing
2025-11-01T02:42:11.078Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.6->25.4)
2025-11-01T02:42:23.062Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.1 due to current limit: Active-LoadBalancing
2025-11-01T02:42:23.074Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-01T02:42:35.062Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:42:35.074Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-01T02:42:47.058Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:42:47.074Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-01T02:42:59.058Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:42:59.070Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-01T02:43:11.058Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-01T02:43:11.070Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-01T02:43:23.058Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->24.0)
2025-11-01T02:43:35.054Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:43:47.054Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.0 due to current limit: Active-LoadBalancing
2025-11-01T02:43:47.066Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->23.3)
2025-11-01T02:43:48.003Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.3% (14.0 A)
2025-11-01T02:43:59.054Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.3 due to current limit: Active-LoadBalancing
2025-11-01T02:44:11.050Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.4 due to current limit: Active-LoadBalancing
2025-11-01T02:44:23.050Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:44:35.050Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:44:47.046Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-01T02:44:59.046Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.3 due to current limit: Active-LoadBalancing
2025-11-01T02:45:11.046Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.2 due to current limit: Active-LoadBalancing
2025-11-01T02:45:11.058Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->25.3)
2025-11-01T02:45:23.042Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-01T02:45:23.054Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->24.9)
2025-11-01T02:45:35.042Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:45:35.054Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-01T02:45:47.042Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:45:47.054Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-01T02:45:47.835Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T02:45:47.843Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T02:45:47.855Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T02:45:47.863Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T02:45:48.191Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-01T02:45:48.859Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T02:45:59.039Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->8.8 due to current limit: Active-LoadBalancing
2025-11-01T02:45:59.968Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.7% (8.8 A)
2025-11-01T02:46:11.039Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->11.3 due to current limit: Active-LoadBalancing
2025-11-01T02:46:11.078Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.8% (11.3 A)
2025-11-01T02:46:23.039Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->12.8 due to current limit: Active-LoadBalancing
2025-11-01T02:46:23.199Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.2% (12.7 A)
2025-11-01T02:46:35.035Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->13.7 due to current limit: Active-LoadBalancing
2025-11-01T02:46:35.316Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.7% (13.6 A)
2025-11-01T02:46:47.035Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->14.2 due to current limit: Active-LoadBalancing
2025-11-01T02:46:47.433Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.6% (14.2 A)
2025-11-01T02:46:59.035Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-01T02:46:59.554Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-01T02:47:11.031Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:47:23.031Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:47:47.027Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:48:55.066Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-01T02:49:35.015Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-01T02:49:35.078Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-01T02:49:47.015Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T02:49:59.015Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-01T02:50:11.011Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-01T02:50:11.433Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-01T02:50:23.011Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-01T02:50:35.011Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-01T02:50:59.007Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-01T02:52:40.941Z:USER:taskMaster.c:6684:Socket #1: L1N=234.9V L2N=235.3V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T02:52:40.953Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T02:53:58.433Z:USER:taskMaster.c:6582:Temperature: 30.0 C
2025-11-01T02:55:38.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T02:58:55.003Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-01T03:00:30.347Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-01T03:00:30.355Z:INFO:db_chargingprofi:26: socket 0
2025-11-01T03:00:30.363Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-01T03:00:30.371Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-01T03:00:30.378Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-01T03:00:30.386Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-01T03:00:30.398Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-01T03:00:30.406Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-01T03:00:30.414Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-01T03:00:30.421Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-01T03:00:30.433Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-01T03:00:30.441Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-01T03:00:30.449Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-01T03:00:30.457Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-01T03:00:30.464Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-01T03:00:30.472Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-01T03:00:30.480Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-01T03:00:30.492Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-01T03:00:30.500Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-01T03:00:30.507Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-01T03:00:30.515Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-01T03:00:30.523Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-01T03:00:30.531Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-01T03:02:53.578Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T03:02:53.589Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T03:02:53.597Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.7V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:02:53.613Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T03:02:53.621Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T03:02:53.632Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T03:02:53.640Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T03:02:53.902Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T03:02:54.574Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T03:02:58.933Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.9 due to current limit: ChargingProfile
2025-11-01T03:02:58.976Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-01T03:02:59.621Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-01T03:03:23.625Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=232.7V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:03:23.636Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-11-01T03:03:53.554Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T03:03:53.621Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=233.0V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:03:53.632Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-11-01T03:03:58.925Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.7 due to current limit: Active-LoadBalancing
2025-11-01T03:03:58.937Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->26.1)
2025-11-01T03:03:58.968Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T03:04:10.925Z:INFO:taskMain.c:5996:Socket #1: Active current 15.7->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:04:10.937Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.1->25.2)
2025-11-01T03:04:11.324Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.2% (15.1 A)
2025-11-01T03:04:22.921Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:04:22.937Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.3)
2025-11-01T03:04:23.445Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-01T03:04:23.617Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=233.2V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:04:23.628Z:USER:taskMaster.c:6720:Socket #1: I1=14.7A I2=14.7A I3=14.7A P=10.3kW Idc=0.7mA
2025-11-01T03:04:34.921Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T03:04:34.933Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-01T03:04:46.921Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-01T03:04:46.933Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.7)
2025-11-01T03:04:53.613Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=233.0V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:04:53.628Z:USER:taskMaster.c:6720:Socket #1: I1=13.8A I2=13.9A I3=13.8A P=9.7kW Idc=0.7mA
2025-11-01T03:04:58.917Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-01T03:04:58.933Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.7->23.5)
2025-11-01T03:05:10.917Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-01T03:05:22.917Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:05:23.609Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=233.1V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:05:23.625Z:USER:taskMaster.c:6720:Socket #1: I1=13.9A I2=14.0A I3=14.0A P=9.8kW Idc=0.7mA
2025-11-01T03:05:34.914Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-01T03:05:34.929Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-01T03:05:46.914Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-01T03:05:46.925Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-01T03:05:53.609Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=233.2V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:05:53.621Z:USER:taskMaster.c:6720:Socket #1: I1=13.8A I2=13.9A I3=13.8A P=9.7kW Idc=0.7mA
2025-11-01T03:05:58.914Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-01T03:05:58.925Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-01T03:06:10.910Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-01T03:06:22.910Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:06:23.605Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=233.3V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:06:23.621Z:USER:taskMaster.c:6720:Socket #1: I1=13.9A I2=14.0A I3=14.0A P=9.8kW Idc=0.7mA
2025-11-01T03:06:34.910Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-01T03:06:34.921Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-01T03:06:46.910Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-01T03:06:46.921Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-01T03:06:53.652Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=233.5V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:06:53.664Z:USER:taskMaster.c:6720:Socket #1: I1=13.8A I2=13.9A I3=13.8A P=9.7kW Idc=0.7mA
2025-11-01T03:06:58.906Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-01T03:06:58.917Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-01T03:07:10.906Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-01T03:07:22.906Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:07:23.648Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=233.4V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:07:23.660Z:USER:taskMaster.c:6720:Socket #1: I1=13.9A I2=14.0A I3=13.9A P=9.8kW Idc=0.7mA
2025-11-01T03:07:34.902Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:07:46.902Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:07:53.644Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=233.4V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:07:53.656Z:USER:taskMaster.c:6720:Socket #1: I1=14.6A I2=14.7A I3=14.6A P=10.2kW Idc=0.7mA
2025-11-01T03:07:53.667Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-01T03:07:58.902Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:07:58.914Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-01T03:08:10.898Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:08:10.910Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:08:22.898Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:08:22.910Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T03:08:34.898Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T03:08:34.910Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-01T03:08:46.894Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:08:54.937Z:INFO:active_lb.c:308:SMt:(14.0 15.0 15.0)A Free:(2.0 1.0 1.0)A ALB:(15.6 14.7 15.2)A
2025-11-01T03:08:58.839Z:USER:taskMaster.c:6582:Temperature: 29.0 C
2025-11-01T03:08:58.894Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:09:10.894Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:09:22.890Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:09:22.906Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-01T03:09:34.890Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:09:34.902Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-01T03:09:46.890Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:09:46.902Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-01T03:09:58.886Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:10:10.886Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:10:22.886Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:10:22.898Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-01T03:10:34.882Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:10:34.898Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:10:38.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T03:10:46.882Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.5)
2025-11-01T03:10:58.882Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:10:58.894Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-01T03:11:10.878Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T03:11:10.894Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-01T03:11:22.878Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:11:34.878Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:11:46.875Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-01T03:11:58.875Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.9)
2025-11-01T03:12:10.875Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:12:10.886Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-01T03:12:22.871Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:12:22.886Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-01T03:12:34.871Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-01T03:12:34.882Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-01T03:12:46.871Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:12:58.867Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-01T03:13:10.867Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-01T03:13:22.867Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:13:22.878Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.2)
2025-11-01T03:13:34.867Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-01T03:13:34.878Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-01T03:13:46.863Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:13:46.875Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-01T03:13:58.863Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:13:58.875Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-01T03:14:10.863Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-01T03:14:10.875Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-01T03:14:22.859Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-01T03:14:22.871Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-01T03:14:34.859Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:14:46.859Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->13.9 due to current limit: Active-LoadBalancing
2025-11-01T03:14:46.871Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->23.1)
2025-11-01T03:14:47.566Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.1% (13.9 A)
2025-11-01T03:14:58.855Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->14.1 due to current limit: Active-LoadBalancing
2025-11-01T03:15:10.855Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:15:11.804Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.4% (14.6 A)
2025-11-01T03:15:22.855Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:15:34.851Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:15:46.851Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-01T03:15:46.863Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->25.0)
2025-11-01T03:15:58.851Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:15:58.863Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-01T03:16:10.847Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:16:10.863Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:16:22.847Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:16:22.859Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T03:16:34.847Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:16:46.843Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:16:58.843Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:16:58.855Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-01T03:17:10.843Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:17:10.855Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:17:22.839Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:17:22.855Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T03:17:34.839Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:17:46.839Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-01T03:17:58.835Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-01T03:18:10.835Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:18:10.847Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-01T03:18:22.835Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:18:22.847Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-01T03:18:34.832Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:18:34.847Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:18:46.832Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:18:46.843Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T03:18:54.875Z:INFO:active_lb.c:308:SMt:(15.0 15.0 15.0)A Free:(1.0 1.0 1.0)A ALB:(15.5 14.6 15.3)A
2025-11-01T03:18:58.832Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:19:10.828Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:19:22.828Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:19:22.839Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-01T03:19:34.828Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:19:34.839Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:19:46.824Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:19:46.839Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T03:19:58.824Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:20:10.824Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:20:22.820Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:20:22.835Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-01T03:20:34.820Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:20:34.832Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:20:46.820Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:20:46.832Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T03:20:58.816Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:21:10.816Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:21:22.816Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:21:22.828Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-01T03:21:34.816Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:21:34.828Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:21:46.812Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:21:46.824Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T03:21:58.812Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:22:10.812Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:22:22.808Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:22:22.820Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-01T03:22:34.808Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:22:34.820Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:22:46.808Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:22:46.820Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-01T03:22:53.550Z:USER:taskMaster.c:6684:Socket #1: L1N=233.4V L2N=234.0V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:22:53.562Z:USER:taskMaster.c:6720:Socket #1: I1=14.1A I2=14.2A I3=14.1A P=9.9kW Idc=0.7mA
2025-11-01T03:22:58.804Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T03:22:58.816Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-01T03:23:10.804Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:23:22.804Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:23:34.800Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:23:35.750Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.2% (15.1 A)
2025-11-01T03:23:46.800Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.4 due to current limit: Active-LoadBalancing
2025-11-01T03:23:58.800Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.2 due to current limit: Active-LoadBalancing
2025-11-01T03:23:58.812Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.6->25.3)
2025-11-01T03:23:59.242Z:USER:taskMaster.c:6582:Temperature: 30.2 C
2025-11-01T03:24:10.796Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:24:10.812Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-01T03:24:22.796Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:24:22.808Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-01T03:24:34.796Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:24:34.808Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:24:46.792Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:24:46.808Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T03:24:58.792Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:25:10.792Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:25:22.789Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:25:22.804Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-01T03:25:34.789Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:25:34.800Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:25:38.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T03:25:46.789Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:25:46.800Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T03:25:58.785Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:26:10.785Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:26:22.785Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:26:22.796Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-01T03:26:34.781Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:26:34.796Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:26:46.781Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:26:46.792Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T03:26:58.781Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:27:10.777Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:27:22.777Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:27:22.789Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-01T03:27:34.777Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:27:34.789Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:27:46.773Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:27:46.789Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T03:27:58.773Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T03:27:58.785Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-01T03:28:10.773Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:28:22.769Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:28:34.769Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:28:46.769Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-01T03:28:46.781Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-01T03:28:54.812Z:INFO:active_lb.c:308:SMt:(15.0 16.0 15.0)A Free:(1.0 0.0 1.0)A ALB:(15.9 15.0 15.4)A
2025-11-01T03:28:58.765Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:28:58.781Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-01T03:29:10.765Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:29:10.777Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-01T03:29:22.765Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:29:34.761Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:29:46.761Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:29:46.773Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-01T03:29:58.761Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:29:58.773Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:30:10.761Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:30:10.773Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T03:30:22.757Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T03:30:22.769Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-01T03:30:34.757Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:30:46.757Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:30:58.753Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:31:10.753Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-01T03:31:10.765Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-01T03:31:22.753Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:31:22.765Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-01T03:31:34.750Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:31:34.761Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-01T03:31:46.750Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-01T03:31:46.761Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-01T03:31:58.750Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-01T03:31:58.761Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-01T03:32:10.746Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:32:22.746Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:32:34.746Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-01T03:32:46.742Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-01T03:32:58.742Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:32:58.753Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-01T03:33:10.742Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:33:10.753Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-01T03:33:22.738Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:33:22.753Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:33:34.738Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:33:34.750Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T03:33:46.738Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:33:58.734Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-01T03:34:10.734Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-01T03:34:22.734Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:34:22.746Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-01T03:34:34.730Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:34:34.746Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-01T03:34:46.730Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:34:46.742Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:34:58.730Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:34:58.742Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T03:35:10.726Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T03:35:10.742Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-01T03:35:22.726Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:35:34.726Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:35:46.722Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:35:46.738Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:35:58.722Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:35:58.734Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T03:36:10.722Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T03:36:10.734Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->23.9)
2025-11-01T03:36:22.718Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:36:34.718Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->15.0 due to current limit: Active-LoadBalancing
2025-11-01T03:36:35.398Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.0% (15.0 A)
2025-11-01T03:36:46.718Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-01T03:36:58.714Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:36:58.730Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.2)
2025-11-01T03:37:10.714Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-01T03:37:10.726Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-01T03:37:22.714Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:37:22.726Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-01T03:37:34.710Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:37:34.726Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-01T03:37:46.710Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-01T03:37:46.722Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-01T03:37:53.453Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=233.6V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:37:53.468Z:USER:taskMaster.c:6720:Socket #1: I1=14.1A I2=14.1A I3=14.1A P=9.9kW Idc=0.7mA
2025-11-01T03:37:58.710Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:38:10.707Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-01T03:38:22.707Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-01T03:38:34.707Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:38:34.718Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-01T03:38:46.707Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:38:46.718Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-01T03:38:54.750Z:INFO:active_lb.c:308:SMt:(15.0 16.0 15.0)A Free:(1.0 0.0 1.0)A ALB:(15.7 14.9 15.2)A
2025-11-01T03:38:58.703Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:38:58.714Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:38:59.597Z:USER:taskMaster.c:6582:Temperature: 30.9 C
2025-11-01T03:39:10.703Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:39:10.714Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T03:39:22.703Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:39:34.699Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-01T03:39:46.699Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-01T03:39:58.699Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.5 due to current limit: Active-LoadBalancing
2025-11-01T03:40:10.695Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.3 due to current limit: Active-LoadBalancing
2025-11-01T03:40:10.707Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.8->25.5)
2025-11-01T03:40:22.695Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.2 due to current limit: Active-LoadBalancing
2025-11-01T03:40:22.707Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->25.3)
2025-11-01T03:40:34.695Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-01T03:40:34.707Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-01T03:40:38.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T03:40:46.691Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:40:46.707Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-01T03:40:58.691Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:40:58.703Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:41:10.691Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:41:10.703Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T03:41:22.687Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:41:34.687Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:41:46.687Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:41:46.699Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-01T03:41:58.683Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:41:58.699Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:42:10.683Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:42:10.695Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-01T03:42:20.777Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T03:42:20.785Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T03:42:20.792Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T03:42:20.804Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T03:42:20.812Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T03:42:21.792Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T03:42:22.683Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->9.2 due to current limit: Active-LoadBalancing
2025-11-01T03:42:22.800Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.2% (9.1 A)
2025-11-01T03:42:34.679Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->5.9 due to current limit: Active-LoadBalancing
2025-11-01T03:42:34.695Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.90) < minimum current(6.00)
2025-11-01T03:42:34.726Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T03:42:34.734Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T03:42:34.746Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T03:42:34.921Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-01T03:42:35.722Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-11-01T03:42:35.722Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T03:42:46.679Z:INFO:taskMain.c:5996:Socket #1: Active current 5.9->9.5 due to current limit: Active-LoadBalancing
2025-11-01T03:42:46.722Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T03:42:46.734Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T03:42:46.742Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T03:42:46.828Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T03:42:46.835Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.8% (9.5 A)
2025-11-01T03:42:47.730Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T03:42:58.679Z:INFO:taskMain.c:5996:Socket #1: Active current 9.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T03:42:58.839Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.5% (11.7 A)
2025-11-01T03:43:10.675Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->13.0 due to current limit: Active-LoadBalancing
2025-11-01T03:43:10.957Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.7% (13.0 A)
2025-11-01T03:43:16.769Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-01T03:43:16.781Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-01T03:43:17.015Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-01T03:43:17.023Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-01T03:43:17.765Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-01T03:43:20.769Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T03:43:20.796Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T03:43:20.804Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-01T03:43:21.269Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T03:43:21.281Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T03:43:21.804Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T03:43:22.296Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T03:43:22.675Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.8 due to current limit: Active-LoadBalancing
2025-11-01T03:43:23.304Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-01T03:43:34.675Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->14.3 due to current limit: Active-LoadBalancing
2025-11-01T03:43:35.425Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.8% (14.3 A)
2025-11-01T03:43:46.671Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:43:58.671Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:44:10.671Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:44:46.667Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.0 due to current limit: Active-LoadBalancing
2025-11-01T03:45:05.957Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T03:45:05.968Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T03:45:05.976Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=234.8V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:45:05.988Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T03:45:06.000Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T03:45:06.007Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T03:45:06.019Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T03:45:06.316Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T03:45:06.976Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T03:45:10.664Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-01T03:45:22.664Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.9 due to current limit: ChargingProfile
2025-11-01T03:45:22.707Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-01T03:45:23.132Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-01T03:45:36.003Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=233.2V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:45:36.019Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-11-01T03:46:05.957Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T03:46:06.003Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=233.0V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:46:06.015Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-11-01T03:46:10.656Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.5 due to current limit: Active-LoadBalancing
2025-11-01T03:46:10.671Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->25.7)
2025-11-01T03:46:10.703Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T03:46:11.609Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.7% (15.4 A)
2025-11-01T03:46:22.656Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:46:22.667Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->24.8)
2025-11-01T03:46:22.714Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.8% (14.9 A)
2025-11-01T03:46:34.656Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:46:34.667Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-01T03:46:36.000Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=233.2V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:46:36.011Z:USER:taskMaster.c:6720:Socket #1: I1=14.5A I2=14.5A I3=14.5A P=10.1kW Idc=0.7mA
2025-11-01T03:46:46.652Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:46:46.667Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-01T03:46:58.652Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T03:46:58.664Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->24.0)
2025-11-01T03:47:05.996Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=233.3V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:47:06.007Z:USER:taskMaster.c:6720:Socket #1: I1=14.0A I2=14.0A I3=14.0A P=9.8kW Idc=0.7mA
2025-11-01T03:47:10.652Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:47:22.652Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:47:34.648Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:47:35.992Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=233.3V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:47:36.003Z:USER:taskMaster.c:6720:Socket #1: I1=14.5A I2=14.5A I3=14.5A P=10.1kW Idc=0.7mA
2025-11-01T03:47:46.648Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:47:46.660Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-01T03:47:58.648Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:47:58.660Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.6)
2025-11-01T03:48:05.988Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.5V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:48:06.003Z:USER:taskMaster.c:6720:Socket #1: I1=14.3A I2=14.4A I3=14.3A P=10.0kW Idc=0.7mA
2025-11-01T03:48:10.644Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:48:10.656Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-01T03:48:22.644Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:48:34.644Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-01T03:48:35.988Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=233.2V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:48:36.000Z:USER:taskMaster.c:6720:Socket #1: I1=14.5A I2=14.5A I3=14.5A P=10.1kW Idc=0.7mA
2025-11-01T03:48:46.640Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-01T03:48:46.652Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-01T03:48:54.683Z:INFO:active_lb.c:308:SMt:(15.0 16.0 15.0)A Free:(1.0 0.0 1.0)A ALB:(15.6 15.0 15.5)A
2025-11-01T03:48:58.640Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:48:58.652Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-01T03:49:05.984Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=233.3V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:49:05.996Z:USER:taskMaster.c:6720:Socket #1: I1=14.5A I2=14.5A I3=14.5A P=10.1kW Idc=0.7mA
2025-11-01T03:49:10.640Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:49:10.652Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-01T03:49:22.636Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-01T03:49:22.652Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-01T03:49:34.636Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:49:35.980Z:USER:taskMaster.c:6684:Socket #1: L1N=233.2V L2N=233.5V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:49:35.992Z:USER:taskMaster.c:6720:Socket #1: I1=14.2A I2=14.2A I3=14.1A P=9.9kW Idc=0.7mA
2025-11-01T03:49:46.636Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-01T03:49:58.632Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-01T03:50:05.976Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.5V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T03:50:05.988Z:USER:taskMaster.c:6720:Socket #1: I1=14.9A I2=15.0A I3=15.0A P=10.5kW Idc=0.7mA
2025-11-01T03:50:06.000Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-01T03:50:10.632Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.6 due to current limit: Active-LoadBalancing
2025-11-01T03:50:22.632Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.4 due to current limit: Active-LoadBalancing
2025-11-01T03:50:22.644Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.9->25.7)
2025-11-01T03:50:34.628Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:50:34.644Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->24.8)
2025-11-01T03:50:35.199Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.8% (14.9 A)
2025-11-01T03:50:45.722Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T03:50:45.734Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T03:50:45.742Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T03:50:45.750Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T03:50:46.308Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-01T03:50:46.628Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.2 due to current limit: Active-LoadBalancing
2025-11-01T03:50:46.757Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.6% (14.2 A)
2025-11-01T03:50:46.765Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T03:50:58.628Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->8.5 due to current limit: Active-LoadBalancing
2025-11-01T03:50:58.878Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.2% (8.5 A)
2025-11-01T03:51:10.625Z:INFO:taskMain.c:5996:Socket #1: Active current 8.5->8.2 due to current limit: Active-LoadBalancing
2025-11-01T03:51:10.996Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.6% (8.2 A)
2025-11-01T03:51:22.625Z:INFO:taskMain.c:5996:Socket #1: Active current 8.2->10.9 due to current limit: Active-LoadBalancing
2025-11-01T03:51:23.113Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.1% (10.9 A)
2025-11-01T03:51:34.625Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->12.5 due to current limit: Active-LoadBalancing
2025-11-01T03:51:35.234Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-01T03:51:46.621Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->13.5 due to current limit: Active-LoadBalancing
2025-11-01T03:51:47.351Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.5% (13.5 A)
2025-11-01T03:51:58.621Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->14.1 due to current limit: Active-LoadBalancing
2025-11-01T03:51:59.472Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.5% (14.1 A)
2025-11-01T03:52:10.621Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.5 due to current limit: Active-LoadBalancing
2025-11-01T03:52:11.589Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-01T03:52:22.617Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-01T03:52:34.617Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-01T03:52:58.613Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-01T03:53:34.609Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-01T03:53:35.410Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-01T03:53:46.609Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T03:53:58.609Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-01T03:54:00.003Z:USER:taskMaster.c:6582:Temperature: 30.9 C
2025-11-01T03:54:22.605Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->13.7 due to current limit: Active-LoadBalancing
2025-11-01T03:54:22.875Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.7% (13.6 A)
2025-11-01T03:54:34.605Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-11-01T03:54:58.601Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-01T03:55:38.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T03:56:34.593Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-01T03:56:35.171Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-01T03:56:46.589Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-01T03:56:58.589Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-11-01T03:57:10.589Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.9 due to current limit: Active-LoadBalancing
2025-11-01T03:57:11.527Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.2% (13.9 A)
2025-11-01T03:58:46.578Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.2 due to current limit: Active-LoadBalancing
2025-11-01T03:58:47.468Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.9% (13.1 A)
2025-11-01T03:58:54.621Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 13.2 15.0)A
2025-11-01T03:58:58.578Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.9 due to current limit: Active-LoadBalancing
2025-11-01T03:58:58.589Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.1% (13.9 A)
2025-11-01T04:00:34.566Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.4 due to current limit: Active-LoadBalancing
2025-11-01T04:00:35.527Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-01T04:00:37.914Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-01T04:00:37.921Z:INFO:db_chargingprofi:26: socket 0
2025-11-01T04:00:37.929Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-01T04:00:37.937Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-01T04:00:37.945Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-01T04:00:37.957Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-01T04:00:37.968Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-01T04:00:37.976Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-01T04:00:37.984Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-01T04:00:37.992Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-01T04:00:38.000Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-01T04:00:38.007Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-01T04:00:38.015Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-01T04:00:38.023Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-01T04:00:38.031Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-01T04:00:38.042Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-01T04:00:38.050Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-01T04:00:38.058Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-01T04:00:38.070Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-01T04:00:38.078Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-01T04:00:38.085Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-01T04:00:38.093Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-01T04:00:38.101Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-01T04:00:46.566Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->12.4 due to current limit: Active-LoadBalancing
2025-11-01T04:00:46.636Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-11-01T04:00:58.562Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->11.9 due to current limit: Active-LoadBalancing
2025-11-01T04:00:58.753Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.7% (11.8 A)
2025-11-01T04:01:10.562Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.5 due to current limit: Active-LoadBalancing
2025-11-01T04:01:10.871Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.1% (11.5 A)
2025-11-01T04:01:22.562Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T04:01:34.558Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-01T04:01:58.558Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.1 due to current limit: Active-LoadBalancing
2025-11-01T04:02:19.050Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:02:19.058Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:02:19.066Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.1V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:02:19.082Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:02:19.089Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:02:19.097Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:02:19.109Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:02:19.546Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:02:20.054Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:02:22.554Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.8 due to current limit: Active-LoadBalancing
2025-11-01T04:02:23.085Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.7% (11.8 A)
2025-11-01T04:02:34.554Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->15.9 due to current limit: ChargingProfile
2025-11-01T04:02:34.597Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-01T04:02:35.203Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-01T04:02:46.550Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->26.4)
2025-11-01T04:02:46.597Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:02:49.097Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=232.5V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:02:49.109Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.5A I3=15.4A P=10.7kW Idc=0.7mA
2025-11-01T04:02:58.550Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->14.9 due to current limit: Active-LoadBalancing
2025-11-01T04:02:58.562Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.4->24.7)
2025-11-01T04:02:59.441Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.7% (14.8 A)
2025-11-01T04:03:10.550Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->13.1 due to current limit: Active-LoadBalancing
2025-11-01T04:03:10.562Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->21.7)
2025-11-01T04:03:10.574Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.7% (13.0 A)
2025-11-01T04:03:19.039Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:03:19.093Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=232.7V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:03:19.105Z:USER:taskMaster.c:6720:Socket #1: I1=12.7A I2=12.7A I3=12.6A P=8.8kW Idc=0.7mA
2025-11-01T04:03:22.550Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->11.3 due to current limit: Active-LoadBalancing
2025-11-01T04:03:22.562Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.7->18.8)
2025-11-01T04:03:22.667Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.8% (11.3 A)
2025-11-01T04:03:34.546Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->10.7 due to current limit: Active-LoadBalancing
2025-11-01T04:03:34.558Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->17.8)
2025-11-01T04:03:34.789Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.8% (10.7 A)
2025-11-01T04:03:46.546Z:INFO:taskMain.c:5996:Socket #1: Active current 10.7->10.5 due to current limit: Active-LoadBalancing
2025-11-01T04:03:46.558Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (17.8->17.5)
2025-11-01T04:03:49.089Z:USER:taskMaster.c:6684:Socket #1: L1N=233.2V L2N=233.1V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:03:49.101Z:USER:taskMaster.c:6720:Socket #1: I1=10.2A I2=10.2A I3=10.2A P=7.1kW Idc=0.7mA
2025-11-01T04:03:58.546Z:INFO:taskMain.c:5996:Socket #1: Active current 10.5->10.8 due to current limit: Active-LoadBalancing
2025-11-01T04:04:10.542Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->11.0 due to current limit: Active-LoadBalancing
2025-11-01T04:04:19.085Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=233.1V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:04:19.097Z:USER:taskMaster.c:6720:Socket #1: I1=10.7A I2=10.7A I3=10.7A P=7.5kW Idc=0.7mA
2025-11-01T04:04:22.542Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.3 due to current limit: Active-LoadBalancing
2025-11-01T04:04:34.542Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-01T04:04:46.539Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T04:04:46.550Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-01T04:04:49.132Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=233.0V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:04:49.148Z:USER:taskMaster.c:6720:Socket #1: I1=10.9A I2=11.0A I3=10.9A P=7.6kW Idc=0.7mA
2025-11-01T04:04:58.539Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-01T04:04:58.550Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T04:05:10.539Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-01T04:05:10.550Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-01T04:05:19.179Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.1V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:05:19.191Z:USER:taskMaster.c:6720:Socket #1: I1=10.6A I2=10.6A I3=10.6A P=7.4kW Idc=0.7mA
2025-11-01T04:05:22.535Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->10.8 due to current limit: Active-LoadBalancing
2025-11-01T04:05:22.550Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.3->18.0)
2025-11-01T04:05:34.535Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->11.1 due to current limit: Active-LoadBalancing
2025-11-01T04:05:46.535Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-01T04:05:49.175Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=233.0V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:05:49.191Z:USER:taskMaster.c:6720:Socket #1: I1=10.9A I2=10.9A I3=10.9A P=7.6kW Idc=0.7mA
2025-11-01T04:05:58.531Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-01T04:05:58.546Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.4)
2025-11-01T04:06:10.531Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->8.5 due to current limit: Active-LoadBalancing
2025-11-01T04:06:10.542Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.4->14.2)
2025-11-01T04:06:11.320Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.2% (8.5 A)
2025-11-01T04:06:19.175Z:USER:taskMaster.c:6684:Socket #1: L1N=233.4V L2N=232.6V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:06:19.187Z:USER:taskMaster.c:6720:Socket #1: I1=8.3A I2=8.3A I3=8.2A P=5.7kW Idc=0.7mA
2025-11-01T04:06:22.531Z:INFO:taskMain.c:5996:Socket #1: Active current 8.5->10.0 due to current limit: Active-LoadBalancing
2025-11-01T04:06:23.441Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.6% (10.0 A)
2025-11-01T04:06:34.527Z:INFO:taskMain.c:5996:Socket #1: Active current 10.0->8.7 due to current limit: Active-LoadBalancing
2025-11-01T04:06:34.542Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (16.6->14.4)
2025-11-01T04:06:34.554Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.4% (8.6 A)
2025-11-01T04:06:46.527Z:INFO:taskMain.c:5996:Socket #1: Active current 8.7->6.9 due to current limit: Active-LoadBalancing
2025-11-01T04:06:46.539Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.4->11.5)
2025-11-01T04:06:46.667Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.5% (6.9 A)
2025-11-01T04:06:49.171Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=232.8V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:06:49.183Z:USER:taskMaster.c:6720:Socket #1: I1=7.7A I2=7.5A I3=6.7A P=4.6kW Idc=0.7mA
2025-11-01T04:06:58.527Z:INFO:taskMain.c:5996:Socket #1: Active current 6.9->5.6 due to current limit: Active-LoadBalancing
2025-11-01T04:06:58.539Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.5->11.5)
2025-11-01T04:06:58.550Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.61) < minimum current(6.00)
2025-11-01T04:06:58.570Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:06:58.582Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:06:58.589Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:06:58.785Z:INFO:taskMain.c:6499:Socket #1: CPlow 6.3 V
2025-11-01T04:06:59.519Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:06:59.527Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:06:59.574Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T04:06:59.582Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-01T04:06:59.589Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.2/9.3, tag: 04BB
2025-11-01T04:06:59.589Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:07:10.523Z:INFO:taskMain.c:5996:Socket #1: Active current 5.6->2.2 due to current limit: Active-LoadBalancing
2025-11-01T04:07:19.167Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=233.7V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:07:19.179Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:07:19.191Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-01T04:07:22.523Z:INFO:taskMain.c:5996:Socket #1: Active current 2.2->0.9 due to current limit: Active-LoadBalancing
2025-11-01T04:07:34.523Z:INFO:taskMain.c:5996:Socket #1: Active current 0.9->2.5 due to current limit: Active-LoadBalancing
2025-11-01T04:07:46.519Z:INFO:taskMain.c:5996:Socket #1: Active current 2.5->3.5 due to current limit: Active-LoadBalancing
2025-11-01T04:07:58.519Z:INFO:taskMain.c:5996:Socket #1: Active current 3.5->4.1 due to current limit: Active-LoadBalancing
2025-11-01T04:08:10.519Z:INFO:taskMain.c:5996:Socket #1: Active current 4.1->4.5 due to current limit: Active-LoadBalancing
2025-11-01T04:08:22.515Z:INFO:taskMain.c:5996:Socket #1: Active current 4.5->4.7 due to current limit: Active-LoadBalancing
2025-11-01T04:08:34.515Z:INFO:taskMain.c:5996:Socket #1: Active current 4.7->4.8 due to current limit: Active-LoadBalancing
2025-11-01T04:08:54.558Z:INFO:active_lb.c:308:SMt:(1.0 11.0 5.0)A Free:(15.0 5.0 11.0)A ALB:(14.9 4.9 10.9)A
2025-11-01T04:08:58.511Z:INFO:taskMain.c:5996:Socket #1: Active current 4.9->4.9 due to current limit: Active-LoadBalancing
2025-11-01T04:09:00.359Z:USER:taskMaster.c:6582:Temperature: 29.4 C
2025-11-01T04:09:10.511Z:INFO:taskMain.c:5996:Socket #1: Active current 4.9->5.4 due to current limit: Active-LoadBalancing
2025-11-01T04:09:22.511Z:INFO:taskMain.c:5996:Socket #1: Active current 5.4->5.6 due to current limit: Active-LoadBalancing
2025-11-01T04:09:34.507Z:INFO:taskMain.c:5996:Socket #1: Active current 5.6->5.4 due to current limit: Active-LoadBalancing
2025-11-01T04:09:46.507Z:INFO:taskMain.c:5996:Socket #1: Active current 5.4->5.6 due to current limit: Active-LoadBalancing
2025-11-01T04:09:58.507Z:INFO:taskMain.c:5996:Socket #1: Active current 5.6->5.8 due to current limit: Active-LoadBalancing
2025-11-01T04:10:22.503Z:INFO:taskMain.c:5996:Socket #1: Active current 5.9->5.9 due to current limit: Active-LoadBalancing
2025-11-01T04:10:34.503Z:INFO:taskMain.c:5996:Socket #1: Active current 5.9->9.6 due to current limit: Active-LoadBalancing
2025-11-01T04:10:34.546Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:10:34.558Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:10:34.566Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:10:34.683Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.6 V
2025-11-01T04:10:34.691Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.9% (9.5 A)
2025-11-01T04:10:35.554Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:10:36.246Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:10:36.257Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:10:36.265Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=234.4V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:10:36.277Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:10:36.289Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:10:36.296Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:10:36.304Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:10:36.562Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:10:37.234Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:10:38.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T04:10:46.503Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->14.7 due to current limit: Active-LoadBalancing
2025-11-01T04:10:47.332Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.4% (14.6 A)
2025-11-01T04:10:58.500Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.9 due to current limit: ChargingProfile
2025-11-01T04:10:58.542Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-01T04:10:59.449Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-01T04:11:06.292Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=232.8V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:11:06.304Z:USER:taskMaster.c:6720:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-11-01T04:11:34.496Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->14.2 due to current limit: Active-LoadBalancing
2025-11-01T04:11:34.507Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->23.7)
2025-11-01T04:11:34.539Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:11:34.796Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.7% (14.2 A)
2025-11-01T04:11:36.214Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:11:36.289Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=232.2V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:11:36.304Z:USER:taskMaster.c:6720:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.6kW Idc=0.7mA
2025-11-01T04:11:44.046Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->2.3 due to current limit: Active-LoadBalancing
2025-11-01T04:11:44.058Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.7->23.7)
2025-11-01T04:11:44.070Z:WARNING:taskMain.c:4698:Socket #1: maximum current(2.35) < minimum current(6.00)
2025-11-01T04:11:44.089Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:11:44.101Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:11:44.109Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:11:44.894Z:INFO:taskMain.c:6499:Socket #1: CPlow 6.3 V
2025-11-01T04:11:44.988Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:11:45.000Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:11:45.093Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T04:11:45.101Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-01T04:11:45.109Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.2/9.3, tag: 04BB
2025-11-01T04:11:45.109Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:11:54.093Z:INFO:taskMain.c:5996:Socket #1: Active current 2.3->0.0 due to current limit: Active-LoadBalancing
2025-11-01T04:12:06.093Z:INFO:taskMain.c:5996:Socket #1: Active current 0.0->0.4 due to current limit: Active-LoadBalancing
2025-11-01T04:12:06.289Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=233.7V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:12:06.300Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:12:18.093Z:INFO:taskMain.c:5996:Socket #1: Active current 0.4->2.6 due to current limit: Active-LoadBalancing
2025-11-01T04:12:30.089Z:INFO:taskMain.c:5996:Socket #1: Active current 2.6->4.0 due to current limit: Active-LoadBalancing
2025-11-01T04:12:36.285Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.3V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:12:36.296Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:12:42.089Z:INFO:taskMain.c:5996:Socket #1: Active current 4.0->4.4 due to current limit: Active-LoadBalancing
2025-11-01T04:12:54.089Z:INFO:taskMain.c:5996:Socket #1: Active current 4.4->8.6 due to current limit: Active-LoadBalancing
2025-11-01T04:12:54.132Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:12:54.144Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:12:54.152Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:12:54.777Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T04:12:54.785Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.3% (8.6 A)
2025-11-01T04:12:55.132Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:12:55.140Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:12:55.152Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.3V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:12:55.164Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:12:55.171Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:12:55.183Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:12:55.191Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:12:55.789Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:12:56.136Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:13:06.085Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->13.8 due to current limit: Active-LoadBalancing
2025-11-01T04:13:06.238Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-01T04:13:18.085Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->15.9 due to current limit: ChargingProfile
2025-11-01T04:13:18.128Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-01T04:13:18.355Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-01T04:13:25.179Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=231.9V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:13:25.191Z:USER:taskMaster.c:6720:Socket #1: I1=15.6A I2=15.5A I3=15.5A P=10.8kW Idc=0.7mA
2025-11-01T04:13:44.285Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->3.3 due to current limit: Active-LoadBalancing
2025-11-01T04:13:44.296Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->26.5)
2025-11-01T04:13:44.308Z:WARNING:taskMain.c:4698:Socket #1: maximum current(3.34) < minimum current(6.00)
2025-11-01T04:13:44.328Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:13:44.339Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:13:44.351Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:13:44.613Z:INFO:taskMain.c:6499:Socket #1: CPlow 6.3 V
2025-11-01T04:13:45.328Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:13:45.335Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T04:13:45.343Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-01T04:13:45.351Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.2/9.3, tag: 04BB
2025-11-01T04:13:45.351Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:13:45.371Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:13:54.332Z:INFO:taskMain.c:5996:Socket #1: Active current 3.3->0.0 due to current limit: Active-LoadBalancing
2025-11-01T04:13:55.121Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:13:55.175Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=233.4V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:13:55.187Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:14:18.328Z:INFO:taskMain.c:5996:Socket #1: Active current 0.0->2.4 due to current limit: Active-LoadBalancing
2025-11-01T04:14:25.171Z:USER:taskMaster.c:6684:Socket #1: L1N=234.3V L2N=234.4V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:14:25.183Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:14:30.328Z:INFO:taskMain.c:5996:Socket #1: Active current 2.4->3.8 due to current limit: Active-LoadBalancing
2025-11-01T04:14:42.328Z:INFO:taskMain.c:5996:Socket #1: Active current 3.8->4.7 due to current limit: Active-LoadBalancing
2025-11-01T04:14:54.324Z:INFO:taskMain.c:5996:Socket #1: Active current 4.7->8.8 due to current limit: Active-LoadBalancing
2025-11-01T04:14:54.371Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:14:54.378Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:14:54.390Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:14:55.015Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T04:14:55.023Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.7% (8.8 A)
2025-11-01T04:14:55.167Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.3V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:14:55.183Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:14:55.320Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:14:55.328Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:14:55.339Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.3V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:14:55.351Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:14:55.359Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:14:55.371Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:14:55.378Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:14:56.027Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:14:56.324Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:15:06.324Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->13.8 due to current limit: Active-LoadBalancing
2025-11-01T04:15:06.425Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.9% (13.7 A)
2025-11-01T04:15:18.324Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->14.8 due to current limit: Active-LoadBalancing
2025-11-01T04:15:18.542Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.6% (14.8 A)
2025-11-01T04:15:25.367Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=233.1V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:15:25.378Z:USER:taskMaster.c:6720:Socket #1: I1=14.4A I2=14.4A I3=14.3A P=10.0kW Idc=0.7mA
2025-11-01T04:15:30.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->13.8 due to current limit: Active-LoadBalancing
2025-11-01T04:15:30.335Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->23.0)
2025-11-01T04:15:30.660Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-01T04:15:42.320Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->12.4 due to current limit: Active-LoadBalancing
2025-11-01T04:15:42.332Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.0->20.7)
2025-11-01T04:15:42.781Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-11-01T04:15:54.371Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->11.4 due to current limit: Active-LoadBalancing
2025-11-01T04:15:54.382Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.7->18.9)
2025-11-01T04:15:54.898Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.9% (11.3 A)
2025-11-01T04:15:55.308Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:15:55.363Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=231.8V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:15:55.375Z:USER:taskMaster.c:6720:Socket #1: I1=12.0A I2=12.1A I3=12.0A P=8.4kW Idc=0.7mA
2025-11-01T04:16:06.367Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->8.8 due to current limit: Active-LoadBalancing
2025-11-01T04:16:06.382Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->14.7)
2025-11-01T04:16:07.019Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.7% (8.8 A)
2025-11-01T04:16:18.367Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->6.7 due to current limit: Active-LoadBalancing
2025-11-01T04:16:18.378Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.7->11.1)
2025-11-01T04:16:19.136Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.1% (6.7 A)
2025-11-01T04:16:25.359Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.2V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:16:25.371Z:USER:taskMaster.c:6720:Socket #1: I1=6.3A I2=6.3A I3=6.2A P=4.3kW Idc=0.7mA
2025-11-01T04:16:30.367Z:INFO:taskMain.c:5996:Socket #1: Active current 6.7->5.3 due to current limit: Active-LoadBalancing
2025-11-01T04:16:30.378Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.1->11.1)
2025-11-01T04:16:30.390Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.35) < minimum current(6.00)
2025-11-01T04:16:30.410Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:16:30.421Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:16:30.429Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:16:31.253Z:INFO:taskMain.c:6499:Socket #1: CPlow 6.3 V
2025-11-01T04:16:31.410Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:16:31.417Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T04:16:31.425Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-01T04:16:31.433Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.2/9.2, tag: 04BB
2025-11-01T04:16:31.433Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:16:31.453Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:16:42.363Z:INFO:taskMain.c:5996:Socket #1: Active current 5.3->6.4 due to current limit: Active-LoadBalancing
2025-11-01T04:16:42.410Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:16:42.417Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:16:42.425Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:16:42.523Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T04:16:43.308Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:16:43.316Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:16:43.328Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=233.7V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:16:43.339Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:16:43.351Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:16:43.359Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:16:43.367Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:16:43.535Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:16:44.324Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:16:44.625Z:WARNING:protocolP1.c:505:P1 Device failure: Read CRC Error.
2025-11-01T04:16:54.644Z:USER:protocolP1.c:539:P1 Communications Recovered
2025-11-01T04:16:54.664Z:INFO:taskMain.c:5996:Socket #1: Active current 6.4->11.5 due to current limit: Active-LoadBalancing
2025-11-01T04:16:55.433Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.1% (11.5 A)
2025-11-01T04:17:06.660Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->12.9 due to current limit: Active-LoadBalancing
2025-11-01T04:17:07.550Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.4% (12.8 A)
2025-11-01T04:17:13.355Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=231.9V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:17:13.371Z:USER:taskMaster.c:6720:Socket #1: I1=12.5A I2=12.5A I3=12.5A P=8.7kW Idc=0.7mA
2025-11-01T04:17:18.660Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.7 due to current limit: Active-LoadBalancing
2025-11-01T04:17:18.671Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.4->21.2)
2025-11-01T04:17:30.660Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.2 due to current limit: Active-LoadBalancing
2025-11-01T04:17:30.671Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.2->20.2)
2025-11-01T04:17:30.781Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.2% (12.1 A)
2025-11-01T04:17:42.656Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->11.6 due to current limit: Active-LoadBalancing
2025-11-01T04:17:42.671Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.2->19.3)
2025-11-01T04:17:42.898Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.3% (11.6 A)
2025-11-01T04:17:43.308Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:17:43.351Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=231.5V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:17:43.363Z:USER:taskMaster.c:6720:Socket #1: I1=11.8A I2=11.8A I3=11.8A P=8.2kW Idc=0.7mA
2025-11-01T04:17:54.656Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->10.9 due to current limit: Active-LoadBalancing
2025-11-01T04:17:54.667Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.2)
2025-11-01T04:17:55.015Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.2% (10.9 A)
2025-11-01T04:18:06.656Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->8.4 due to current limit: Active-LoadBalancing
2025-11-01T04:18:06.667Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.2->13.9)
2025-11-01T04:18:07.136Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.9% (8.3 A)
2025-11-01T04:18:13.347Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=232.1V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:18:13.363Z:USER:taskMaster.c:6720:Socket #1: I1=7.9A I2=8.0A I3=7.9A P=5.5kW Idc=0.7mA
2025-11-01T04:18:18.656Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->6.2 due to current limit: Active-LoadBalancing
2025-11-01T04:18:18.667Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (13.9->10.4)
2025-11-01T04:18:19.253Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.4% (6.2 A)
2025-11-01T04:18:30.652Z:INFO:taskMain.c:5996:Socket #1: Active current 6.2->5.3 due to current limit: Active-LoadBalancing
2025-11-01T04:18:30.664Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (10.4->10.4)
2025-11-01T04:18:30.679Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.34) < minimum current(6.00)
2025-11-01T04:18:30.695Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:18:30.707Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:18:30.718Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:18:31.371Z:INFO:taskMain.c:6499:Socket #1: CPlow 6.3 V
2025-11-01T04:18:31.695Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:18:31.707Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T04:18:31.714Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-01T04:18:31.722Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.2/9.2, tag: 04BB
2025-11-01T04:18:31.722Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:18:31.738Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:18:42.652Z:INFO:taskMain.c:5996:Socket #1: Active current 5.3->6.8 due to current limit: Active-LoadBalancing
2025-11-01T04:18:42.695Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:18:42.707Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:18:42.714Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:18:42.812Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T04:18:42.820Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.3% (6.8 A)
2025-11-01T04:18:43.347Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=233.6V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:18:43.359Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:18:43.593Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:18:43.605Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:18:43.613Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=233.6V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:18:43.625Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:18:43.636Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:18:43.644Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:18:43.656Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:18:43.820Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:18:44.621Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:18:44.859Z:WARNING:protocolP1.c:505:P1 Device failure: Read CRC Error.
2025-11-01T04:18:54.496Z:INFO:active_lb.c:308:SMt:(6.0 7.0 11.0)A Free:(10.0 9.0 5.0)A ALB:(12.6 6.8 7.9)A
2025-11-01T04:18:54.878Z:USER:protocolP1.c:539:P1 Communications Recovered
2025-11-01T04:18:54.902Z:INFO:taskMain.c:5996:Socket #1: Active current 6.8->11.7 due to current limit: Active-LoadBalancing
2025-11-01T04:18:55.730Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.5% (11.7 A)
2025-11-01T04:19:06.898Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->13.1 due to current limit: Active-LoadBalancing
2025-11-01T04:19:07.847Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.9% (13.1 A)
2025-11-01T04:19:13.640Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=232.3V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:19:13.656Z:USER:taskMaster.c:6720:Socket #1: I1=12.7A I2=12.8A I3=12.7A P=8.8kW Idc=0.7mA
2025-11-01T04:19:18.898Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.0 due to current limit: Active-LoadBalancing
2025-11-01T04:19:18.910Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.9->21.5)
2025-11-01T04:19:30.898Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.4 due to current limit: Active-LoadBalancing
2025-11-01T04:19:30.910Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.5->20.6)
2025-11-01T04:19:31.078Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-11-01T04:19:42.894Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->11.8 due to current limit: Active-LoadBalancing
2025-11-01T04:19:42.906Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.6->19.6)
2025-11-01T04:19:43.195Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.6% (11.8 A)
2025-11-01T04:19:43.605Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:19:43.640Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=231.8V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:19:43.652Z:USER:taskMaster.c:6720:Socket #1: I1=12.0A I2=12.0A I3=12.0A P=8.3kW Idc=0.7mA
2025-11-01T04:19:54.894Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.0 due to current limit: Active-LoadBalancing
2025-11-01T04:19:54.906Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->18.3)
2025-11-01T04:19:55.312Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.3% (11.0 A)
2025-11-01T04:20:06.894Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->8.4 due to current limit: Active-LoadBalancing
2025-11-01T04:20:06.906Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.3->14.0)
2025-11-01T04:20:07.433Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.0% (8.4 A)
2025-11-01T04:20:13.636Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=232.0V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:20:13.648Z:USER:taskMaster.c:6720:Socket #1: I1=8.1A I2=8.2A I3=8.1A P=5.6kW Idc=0.7mA
2025-11-01T04:20:18.890Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->6.3 due to current limit: Active-LoadBalancing
2025-11-01T04:20:18.902Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.0->10.5)
2025-11-01T04:20:19.550Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.5% (6.3 A)
2025-11-01T04:20:30.890Z:INFO:taskMain.c:5996:Socket #1: Active current 6.3->5.0 due to current limit: Active-LoadBalancing
2025-11-01T04:20:30.902Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (10.5->10.5)
2025-11-01T04:20:30.914Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.00) < minimum current(6.00)
2025-11-01T04:20:30.933Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:20:30.945Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:20:30.953Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:20:31.671Z:INFO:taskMain.c:6499:Socket #1: CPlow 6.3 V
2025-11-01T04:20:31.933Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:20:31.941Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T04:20:31.949Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-01T04:20:31.957Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.2/9.3, tag: 04BB
2025-11-01T04:20:31.957Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:20:31.976Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:20:42.890Z:INFO:taskMain.c:5996:Socket #1: Active current 5.0->6.6 due to current limit: Active-LoadBalancing
2025-11-01T04:20:42.933Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:20:42.941Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:20:42.953Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:20:43.050Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T04:20:43.683Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=233.6V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:20:43.695Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:20:43.933Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:20:43.941Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:20:43.953Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=233.6V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:20:43.964Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:20:43.976Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:20:43.984Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:20:43.992Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:20:44.058Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:20:44.917Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:20:45.097Z:WARNING:protocolP1.c:505:P1 Device failure: Read CRC Error.
2025-11-01T04:20:55.117Z:USER:protocolP1.c:539:P1 Communications Recovered
2025-11-01T04:20:55.136Z:INFO:taskMain.c:5996:Socket #1: Active current 6.6->11.6 due to current limit: Active-LoadBalancing
2025-11-01T04:20:56.027Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.3% (11.6 A)
2025-11-01T04:21:07.136Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->13.4 due to current limit: Active-LoadBalancing
2025-11-01T04:21:07.148Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-01T04:21:13.980Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=232.5V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:21:13.992Z:USER:taskMaster.c:6720:Socket #1: I1=13.0A I2=13.0A I3=13.0A P=9.0kW Idc=0.7mA
2025-11-01T04:21:19.136Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.3 due to current limit: Active-LoadBalancing
2025-11-01T04:21:19.148Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.3->22.1)
2025-11-01T04:21:31.132Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->12.3 due to current limit: Active-LoadBalancing
2025-11-01T04:21:31.148Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.1->20.4)
2025-11-01T04:21:31.375Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.4% (12.2 A)
2025-11-01T04:21:43.132Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->11.7 due to current limit: Active-LoadBalancing
2025-11-01T04:21:43.144Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.4->19.5)
2025-11-01T04:21:43.492Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.5% (11.7 A)
2025-11-01T04:21:43.902Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:21:43.976Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=231.4V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:21:43.988Z:USER:taskMaster.c:6720:Socket #1: I1=11.9A I2=11.9A I3=11.8A P=8.3kW Idc=0.7mA
2025-11-01T04:21:55.132Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.0 due to current limit: Active-LoadBalancing
2025-11-01T04:21:55.144Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->18.3)
2025-11-01T04:21:55.613Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.3% (11.0 A)
2025-11-01T04:22:07.128Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->8.4 due to current limit: Active-LoadBalancing
2025-11-01T04:22:07.144Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.3->14.0)
2025-11-01T04:22:07.730Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.0% (8.4 A)
2025-11-01T04:22:13.972Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=232.2V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:22:13.984Z:USER:taskMaster.c:6720:Socket #1: I1=8.1A I2=8.1A I3=8.1A P=5.6kW Idc=0.7mA
2025-11-01T04:22:19.128Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->6.3 due to current limit: Active-LoadBalancing
2025-11-01T04:22:19.140Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.0->10.5)
2025-11-01T04:22:19.847Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.5% (6.3 A)
2025-11-01T04:22:31.128Z:INFO:taskMain.c:5996:Socket #1: Active current 6.3->5.0 due to current limit: Active-LoadBalancing
2025-11-01T04:22:31.140Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (10.5->10.5)
2025-11-01T04:22:31.152Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.00) < minimum current(6.00)
2025-11-01T04:22:31.171Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:22:31.183Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:22:31.191Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:22:31.968Z:INFO:taskMain.c:6499:Socket #1: CPlow 6.3 V
2025-11-01T04:22:32.121Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:22:32.128Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:22:32.175Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-01T04:22:32.183Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-01T04:22:32.191Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-11-01T04:22:32.191Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:22:43.125Z:INFO:taskMain.c:5996:Socket #1: Active current 5.0->6.6 due to current limit: Active-LoadBalancing
2025-11-01T04:22:43.171Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:22:43.179Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:22:43.187Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:22:43.285Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T04:22:43.968Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=233.6V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:22:43.988Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:22:44.121Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:22:44.128Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:22:44.140Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=233.6V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:22:44.152Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:22:44.164Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:22:44.171Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:22:44.179Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:22:44.296Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:22:45.105Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:22:45.332Z:WARNING:protocolP1.c:505:P1 Device failure: Read CRC Error.
2025-11-01T04:22:55.351Z:USER:protocolP1.c:539:P1 Communications Recovered
2025-11-01T04:22:55.375Z:INFO:taskMain.c:5996:Socket #1: Active current 6.6->10.8 due to current limit: Active-LoadBalancing
2025-11-01T04:22:56.214Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.9% (10.7 A)
2025-11-01T04:23:07.375Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->12.6 due to current limit: Active-LoadBalancing
2025-11-01T04:23:08.332Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-01T04:23:14.167Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=232.6V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:23:14.179Z:USER:taskMaster.c:6720:Socket #1: I1=12.2A I2=12.2A I3=12.2A P=8.5kW Idc=0.7mA
2025-11-01T04:23:19.371Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-11-01T04:23:31.371Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.2 due to current limit: Active-LoadBalancing
2025-11-01T04:23:31.382Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.3->20.3)
2025-11-01T04:23:31.562Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.3% (12.2 A)
2025-11-01T04:23:43.371Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->11.6 due to current limit: Active-LoadBalancing
2025-11-01T04:23:43.382Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.3->19.3)
2025-11-01T04:23:43.679Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.3% (11.6 A)
2025-11-01T04:23:44.089Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:23:44.164Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=231.7V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:23:44.175Z:USER:taskMaster.c:6720:Socket #1: I1=11.8A I2=11.8A I3=11.8A P=8.2kW Idc=0.7mA
2025-11-01T04:23:55.367Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->9.3 due to current limit: Active-LoadBalancing
2025-11-01T04:23:55.382Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->15.4)
2025-11-01T04:23:55.796Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.4% (9.2 A)
2025-11-01T04:24:00.761Z:USER:taskMaster.c:6582:Temperature: 29.2 C
2025-11-01T04:24:07.367Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->6.7 due to current limit: Active-LoadBalancing
2025-11-01T04:24:07.378Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.4->11.2)
2025-11-01T04:24:07.917Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.2% (6.7 A)
2025-11-01T04:24:14.160Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.2V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:24:14.171Z:USER:taskMaster.c:6720:Socket #1: I1=6.5A I2=6.5A I3=6.4A P=4.5kW Idc=0.7mA
2025-11-01T04:24:19.367Z:INFO:taskMain.c:5996:Socket #1: Active current 6.7->5.4 due to current limit: Active-LoadBalancing
2025-11-01T04:24:19.378Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.2->11.2)
2025-11-01T04:24:19.390Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.42) < minimum current(6.00)
2025-11-01T04:24:19.410Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:24:19.421Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:24:19.429Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:24:20.035Z:INFO:taskMain.c:6499:Socket #1: CPlow 6.3 V
2025-11-01T04:24:20.410Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:24:20.417Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T04:24:20.425Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-01T04:24:20.433Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.2/9.2, tag: 04BB
2025-11-01T04:24:20.433Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:24:20.453Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:24:31.363Z:INFO:taskMain.c:5996:Socket #1: Active current 5.4->6.4 due to current limit: Active-LoadBalancing
2025-11-01T04:24:31.410Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:24:31.417Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:24:31.429Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:24:31.523Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T04:24:32.308Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:24:32.320Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:24:32.328Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=233.8V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:24:32.339Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:24:32.351Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:24:32.359Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:24:32.367Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:24:32.535Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:24:33.292Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:24:43.363Z:INFO:taskMain.c:5996:Socket #1: Active current 6.4->11.6 due to current limit: Active-LoadBalancing
2025-11-01T04:24:43.394Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.3% (11.6 A)
2025-11-01T04:24:55.363Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->13.4 due to current limit: Active-LoadBalancing
2025-11-01T04:24:55.511Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-01T04:25:02.355Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=232.5V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:25:02.367Z:USER:taskMaster.c:6720:Socket #1: I1=12.9A I2=13.0A I3=12.9A P=9.0kW Idc=0.7mA
2025-11-01T04:25:07.359Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-11-01T04:25:07.375Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.3->21.9)
2025-11-01T04:25:19.359Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->12.2 due to current limit: Active-LoadBalancing
2025-11-01T04:25:19.371Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.9->20.3)
2025-11-01T04:25:19.750Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.3% (12.2 A)
2025-11-01T04:25:31.359Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->11.6 due to current limit: Active-LoadBalancing
2025-11-01T04:25:31.371Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.3->19.3)
2025-11-01T04:25:31.867Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.3% (11.6 A)
2025-11-01T04:25:32.277Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:25:32.351Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=231.7V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:25:32.363Z:USER:taskMaster.c:6720:Socket #1: I1=11.7A I2=11.8A I3=11.7A P=8.2kW Idc=0.7mA
2025-11-01T04:25:38.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T04:25:43.355Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.0 due to current limit: Active-LoadBalancing
2025-11-01T04:25:43.371Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.3)
2025-11-01T04:25:43.988Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.3% (11.0 A)
2025-11-01T04:25:55.355Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->8.4 due to current limit: Active-LoadBalancing
2025-11-01T04:25:55.367Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.3->14.0)
2025-11-01T04:25:56.105Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.0% (8.4 A)
2025-11-01T04:26:02.347Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=232.0V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:26:02.363Z:USER:taskMaster.c:6720:Socket #1: I1=8.1A I2=8.1A I3=8.1A P=5.6kW Idc=0.7mA
2025-11-01T04:26:07.355Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->6.3 due to current limit: Active-LoadBalancing
2025-11-01T04:26:07.367Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.0->10.5)
2025-11-01T04:26:08.226Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.5% (6.3 A)
2025-11-01T04:26:19.355Z:INFO:taskMain.c:5996:Socket #1: Active current 6.3->9.0 due to current limit: Active-LoadBalancing
2025-11-01T04:26:20.343Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.9% (8.9 A)
2025-11-01T04:26:31.351Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->11.3 due to current limit: Active-LoadBalancing
2025-11-01T04:26:31.453Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.8% (11.3 A)
2025-11-01T04:26:32.347Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=232.6V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:26:32.359Z:USER:taskMaster.c:6720:Socket #1: I1=8.7A I2=8.6A I3=8.6A P=6.0kW Idc=0.7mA
2025-11-01T04:26:43.351Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->12.3 due to current limit: Active-LoadBalancing
2025-11-01T04:26:43.570Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.5% (12.3 A)
2025-11-01T04:26:55.351Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.6 due to current limit: Active-LoadBalancing
2025-11-01T04:27:02.343Z:USER:taskMaster.c:6684:Socket #1: L1N=232.0V L2N=232.1V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:27:02.355Z:USER:taskMaster.c:6720:Socket #1: I1=12.2A I2=12.2A I3=12.2A P=8.5kW Idc=0.7mA
2025-11-01T04:27:07.347Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.0 due to current limit: Active-LoadBalancing
2025-11-01T04:27:07.359Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.9->20.0)
2025-11-01T04:27:07.808Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.0% (12.0 A)
2025-11-01T04:27:19.347Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->11.5 due to current limit: Active-LoadBalancing
2025-11-01T04:27:19.359Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.0->19.1)
2025-11-01T04:27:19.925Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.1% (11.5 A)
2025-11-01T04:27:31.347Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.0 due to current limit: Active-LoadBalancing
2025-11-01T04:27:31.359Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.2)
2025-11-01T04:27:32.046Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.2% (10.9 A)
2025-11-01T04:27:32.339Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=231.5V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:27:32.351Z:USER:taskMaster.c:6720:Socket #1: I1=11.0A I2=11.1A I3=11.0A P=7.7kW Idc=0.7mA
2025-11-01T04:27:43.343Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->8.8 due to current limit: Active-LoadBalancing
2025-11-01T04:27:43.355Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.2->14.7)
2025-11-01T04:27:44.164Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.7% (8.8 A)
2025-11-01T04:27:55.343Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->6.7 due to current limit: Active-LoadBalancing
2025-11-01T04:27:55.355Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.7->11.1)
2025-11-01T04:27:56.285Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.1% (6.7 A)
2025-11-01T04:28:02.335Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=233.0V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:28:02.347Z:USER:taskMaster.c:6720:Socket #1: I1=6.3A I2=6.3A I3=6.3A P=4.4kW Idc=0.7mA
2025-11-01T04:28:07.343Z:INFO:taskMain.c:5996:Socket #1: Active current 6.7->5.4 due to current limit: Active-LoadBalancing
2025-11-01T04:28:07.355Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.1->11.1)
2025-11-01T04:28:07.367Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.36) < minimum current(6.00)
2025-11-01T04:28:07.386Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:28:07.398Z:INFO:taskMain.c:6499:Socket #1: CPlow 3.6 V
2025-11-01T04:28:07.406Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:28:07.414Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:28:08.386Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:28:08.394Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T04:28:08.402Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-01T04:28:08.410Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.2/9.2, tag: 04BB
2025-11-01T04:28:08.410Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:28:08.429Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:28:19.339Z:INFO:taskMain.c:5996:Socket #1: Active current 5.4->6.4 due to current limit: Active-LoadBalancing
2025-11-01T04:28:19.382Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:28:19.394Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:28:19.402Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:28:19.500Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T04:28:20.382Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:28:20.394Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:28:20.402Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=233.6V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:28:20.414Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:28:20.425Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:28:20.433Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:28:20.445Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:28:20.511Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:28:21.390Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:28:24.339Z:INFO:taskMain.c:5996:Socket #1: Active current 6.4->8.0 due to current limit: Active-LoadBalancing
2025-11-01T04:28:24.421Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.2% (7.9 A)
2025-11-01T04:28:29.339Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->6.4 due to current limit: Active-LoadBalancing
2025-11-01T04:28:29.351Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (13.2->10.6)
2025-11-01T04:28:29.468Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.6% (6.4 A)
2025-11-01T04:28:34.339Z:INFO:taskMain.c:5996:Socket #1: Active current 6.4->11.6 due to current limit: Active-LoadBalancing
2025-11-01T04:28:34.519Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.2% (11.5 A)
2025-11-01T04:28:43.339Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->13.0 due to current limit: Active-LoadBalancing
2025-11-01T04:28:43.609Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.6% (13.0 A)
2025-11-01T04:28:50.433Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=232.7V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:28:50.445Z:USER:taskMaster.c:6720:Socket #1: I1=12.6A I2=12.6A I3=12.5A P=8.8kW Idc=0.7mA
2025-11-01T04:28:54.429Z:INFO:active_lb.c:308:SMt:(11.0 6.0 14.0)A Free:(5.0 10.0 2.0)A ALB:(17.1 14.6 13.0)A
2025-11-01T04:28:55.335Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.6 due to current limit: Active-LoadBalancing
2025-11-01T04:28:55.726Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.7% (13.6 A)
2025-11-01T04:29:07.335Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.1 due to current limit: Active-LoadBalancing
2025-11-01T04:29:07.347Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.7->21.7)
2025-11-01T04:29:07.847Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.7% (13.0 A)
2025-11-01T04:29:19.335Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.1 due to current limit: Active-LoadBalancing
2025-11-01T04:29:19.347Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.7->20.2)
2025-11-01T04:29:19.964Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.2% (12.1 A)
2025-11-01T04:29:20.375Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:29:20.429Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=231.7V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:29:20.441Z:USER:taskMaster.c:6720:Socket #1: I1=12.6A I2=12.7A I3=12.7A P=8.8kW Idc=0.7mA
2025-11-01T04:29:31.332Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->11.3 due to current limit: Active-LoadBalancing
2025-11-01T04:29:31.347Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.2->18.7)
2025-11-01T04:29:32.082Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.7% (11.2 A)
2025-11-01T04:29:43.332Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->8.7 due to current limit: Active-LoadBalancing
2025-11-01T04:29:43.343Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->14.5)
2025-11-01T04:29:44.203Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.5% (8.7 A)
2025-11-01T04:29:50.425Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=232.3V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:29:50.437Z:USER:taskMaster.c:6720:Socket #1: I1=8.4A I2=8.4A I3=8.3A P=5.8kW Idc=0.7mA
2025-11-01T04:29:55.332Z:INFO:taskMain.c:5996:Socket #1: Active current 8.7->6.6 due to current limit: Active-LoadBalancing
2025-11-01T04:29:55.343Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.5->10.9)
2025-11-01T04:29:56.320Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.9% (6.5 A)
2025-11-01T04:30:07.328Z:INFO:taskMain.c:5996:Socket #1: Active current 6.6->5.2 due to current limit: Active-LoadBalancing
2025-11-01T04:30:07.343Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (10.9->10.9)
2025-11-01T04:30:07.355Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.22) < minimum current(6.00)
2025-11-01T04:30:07.375Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:30:07.386Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:30:07.394Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:30:07.429Z:INFO:taskMain.c:6499:Socket #1: CPlow 6.3 V
2025-11-01T04:30:08.375Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:30:08.382Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T04:30:08.390Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-01T04:30:08.398Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.2/9.2, tag: 04BB
2025-11-01T04:30:08.398Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:30:08.417Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:30:19.328Z:INFO:taskMain.c:5996:Socket #1: Active current 5.2->6.3 due to current limit: Active-LoadBalancing
2025-11-01T04:30:19.371Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:30:19.382Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:30:19.390Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:30:19.488Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T04:30:20.371Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:30:20.382Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:30:20.390Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=233.8V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:30:20.402Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:30:20.414Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:30:20.421Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:30:20.429Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:30:20.500Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:30:21.386Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:30:31.328Z:INFO:taskMain.c:5996:Socket #1: Active current 6.3->11.7 due to current limit: Active-LoadBalancing
2025-11-01T04:30:31.488Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.5% (11.7 A)
2025-11-01T04:30:43.324Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->13.6 due to current limit: Active-LoadBalancing
2025-11-01T04:30:43.605Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-01T04:30:50.417Z:USER:taskMaster.c:6684:Socket #1: L1N=231.7V L2N=232.1V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:30:50.429Z:USER:taskMaster.c:6720:Socket #1: I1=13.1A I2=13.2A I3=13.1A P=9.1kW Idc=0.7mA
2025-11-01T04:30:55.324Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-01T04:30:55.335Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.6->22.3)
2025-11-01T04:31:07.324Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->12.4 due to current limit: Active-LoadBalancing
2025-11-01T04:31:07.335Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.3->20.6)
2025-11-01T04:31:07.843Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-11-01T04:31:19.320Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->11.4 due to current limit: Active-LoadBalancing
2025-11-01T04:31:19.335Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.6->19.0)
2025-11-01T04:31:19.960Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.0% (11.4 A)
2025-11-01T04:31:20.371Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:31:20.414Z:USER:taskMaster.c:6684:Socket #1: L1N=231.7V L2N=231.1V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:31:20.429Z:USER:taskMaster.c:6720:Socket #1: I1=11.9A I2=12.0A I3=11.9A P=8.3kW Idc=0.7mA
2025-11-01T04:31:31.320Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.0 due to current limit: Active-LoadBalancing
2025-11-01T04:31:31.332Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.2)
2025-11-01T04:31:32.082Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.2% (10.9 A)
2025-11-01T04:31:43.320Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->8.8 due to current limit: Active-LoadBalancing
2025-11-01T04:31:43.332Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.2->14.7)
2025-11-01T04:31:44.199Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.7% (8.8 A)
2025-11-01T04:31:50.414Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=231.8V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:31:50.425Z:USER:taskMaster.c:6720:Socket #1: I1=8.5A I2=8.5A I3=8.5A P=5.9kW Idc=0.7mA
2025-11-01T04:31:55.316Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->6.7 due to current limit: Active-LoadBalancing
2025-11-01T04:31:55.332Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.7->11.1)
2025-11-01T04:31:56.316Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.1% (6.7 A)
2025-11-01T04:32:07.316Z:INFO:taskMain.c:5996:Socket #1: Active current 6.7->5.4 due to current limit: Active-LoadBalancing
2025-11-01T04:32:07.328Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.1->11.1)
2025-11-01T04:32:07.339Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.36) < minimum current(6.00)
2025-11-01T04:32:07.359Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:32:07.371Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:32:07.382Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:32:07.425Z:INFO:taskMain.c:6499:Socket #1: CPlow 6.3 V
2025-11-01T04:32:08.359Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:32:08.371Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.1 V
2025-11-01T04:32:08.378Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-01T04:32:08.382Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.1/9.2, tag: 04BB
2025-11-01T04:32:08.382Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:32:08.402Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:32:19.316Z:INFO:taskMain.c:5996:Socket #1: Active current 5.4->6.4 due to current limit: Active-LoadBalancing
2025-11-01T04:32:19.359Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:32:19.371Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:32:19.378Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:32:19.476Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T04:32:20.257Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:32:20.269Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:32:20.277Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=233.5V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:32:20.289Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:32:20.300Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:32:20.308Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:32:20.320Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:32:20.484Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:32:21.285Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:32:31.312Z:INFO:taskMain.c:5996:Socket #1: Active current 6.4->11.6 due to current limit: Active-LoadBalancing
2025-11-01T04:32:31.382Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.2% (11.5 A)
2025-11-01T04:32:43.312Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->13.4 due to current limit: Active-LoadBalancing
2025-11-01T04:32:43.503Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-01T04:32:50.308Z:USER:taskMaster.c:6684:Socket #1: L1N=231.9V L2N=232.2V L3N=231.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:32:50.320Z:USER:taskMaster.c:6720:Socket #1: I1=12.9A I2=13.0A I3=12.9A P=9.0kW Idc=0.7mA
2025-11-01T04:32:55.312Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-11-01T04:32:55.324Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.3->22.0)
2025-11-01T04:33:07.308Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->12.2 due to current limit: Active-LoadBalancing
2025-11-01T04:33:07.324Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.0->20.4)
2025-11-01T04:33:07.742Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.4% (12.2 A)
2025-11-01T04:33:19.308Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->11.7 due to current limit: Active-LoadBalancing
2025-11-01T04:33:19.320Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.4->19.5)
2025-11-01T04:33:19.859Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.5% (11.7 A)
2025-11-01T04:33:20.269Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:33:20.304Z:USER:taskMaster.c:6684:Socket #1: L1N=231.8V L2N=231.3V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:33:20.316Z:USER:taskMaster.c:6720:Socket #1: I1=11.9A I2=11.9A I3=11.9A P=8.3kW Idc=0.7mA
2025-11-01T04:33:31.308Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.1 due to current limit: Active-LoadBalancing
2025-11-01T04:33:31.320Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->18.5)
2025-11-01T04:33:31.976Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.5% (11.1 A)
2025-11-01T04:33:43.308Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->8.6 due to current limit: Active-LoadBalancing
2025-11-01T04:33:43.320Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->14.3)
2025-11-01T04:33:44.097Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.3% (8.6 A)
2025-11-01T04:33:50.300Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=231.6V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:33:50.312Z:USER:taskMaster.c:6720:Socket #1: I1=8.2A I2=8.2A I3=8.1A P=5.7kW Idc=0.7mA
2025-11-01T04:33:55.304Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->6.5 due to current limit: Active-LoadBalancing
2025-11-01T04:33:55.316Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.3->10.7)
2025-11-01T04:33:56.214Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.7% (6.4 A)
2025-11-01T04:34:07.304Z:INFO:taskMain.c:5996:Socket #1: Active current 6.5->5.1 due to current limit: Active-LoadBalancing
2025-11-01T04:34:07.316Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (10.7->10.7)
2025-11-01T04:34:07.328Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.15) < minimum current(6.00)
2025-11-01T04:34:07.347Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:34:07.359Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:34:07.367Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:34:08.296Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:34:08.308Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:34:08.332Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-01T04:34:08.339Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-01T04:34:08.355Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-11-01T04:34:08.355Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:34:19.304Z:INFO:taskMain.c:5996:Socket #1: Active current 5.1->6.3 due to current limit: Active-LoadBalancing
2025-11-01T04:34:19.347Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:34:19.355Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:34:19.367Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:34:19.460Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T04:34:20.296Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:34:20.304Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:34:20.316Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.5V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:34:20.328Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:34:20.339Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:34:20.347Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:34:20.355Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:34:20.472Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:34:21.281Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:34:31.300Z:INFO:taskMain.c:5996:Socket #1: Active current 6.3->11.7 due to current limit: Active-LoadBalancing
2025-11-01T04:34:31.382Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.4% (11.6 A)
2025-11-01T04:34:43.300Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->13.5 due to current limit: Active-LoadBalancing
2025-11-01T04:34:43.500Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-01T04:34:50.343Z:USER:taskMaster.c:6684:Socket #1: L1N=231.8V L2N=232.4V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:34:50.355Z:USER:taskMaster.c:6720:Socket #1: I1=13.1A I2=13.1A I3=13.1A P=9.1kW Idc=0.7mA
2025-11-01T04:34:55.300Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-11-01T04:34:55.312Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.4->22.1)
2025-11-01T04:35:07.296Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->12.3 due to current limit: Active-LoadBalancing
2025-11-01T04:35:07.308Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.1->20.4)
2025-11-01T04:35:07.738Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.4% (12.2 A)
2025-11-01T04:35:19.296Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->11.7 due to current limit: Active-LoadBalancing
2025-11-01T04:35:19.308Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.4->19.5)
2025-11-01T04:35:19.855Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.5% (11.7 A)
2025-11-01T04:35:20.265Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:35:20.339Z:USER:taskMaster.c:6684:Socket #1: L1N=232.0V L2N=231.6V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:35:20.351Z:USER:taskMaster.c:6720:Socket #1: I1=11.9A I2=11.9A I3=11.9A P=8.3kW Idc=0.7mA
2025-11-01T04:35:31.296Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-01T04:35:31.308Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.3)
2025-11-01T04:35:43.292Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->9.9 due to current limit: Active-LoadBalancing
2025-11-01T04:35:43.304Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->16.4)
2025-11-01T04:35:44.093Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.4% (9.8 A)
2025-11-01T04:35:50.335Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=231.7V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:35:50.347Z:USER:taskMaster.c:6720:Socket #1: I1=9.5A I2=9.5A I3=9.5A P=6.6kW Idc=0.7mA
2025-11-01T04:35:55.292Z:INFO:taskMain.c:5996:Socket #1: Active current 9.9->7.3 due to current limit: Active-LoadBalancing
2025-11-01T04:35:55.304Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (16.4->12.2)
2025-11-01T04:35:56.210Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.2% (7.3 A)
2025-11-01T04:36:07.292Z:INFO:taskMain.c:5996:Socket #1: Active current 7.3->5.6 due to current limit: Active-LoadBalancing
2025-11-01T04:36:07.304Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (12.2->12.2)
2025-11-01T04:36:07.316Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.61) < minimum current(6.00)
2025-11-01T04:36:07.335Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:36:07.347Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:36:07.355Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:36:08.183Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:36:08.195Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:36:08.320Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-01T04:36:08.328Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-01T04:36:08.339Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-11-01T04:36:08.339Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:36:19.289Z:INFO:taskMain.c:5996:Socket #1: Active current 5.6->6.6 due to current limit: Active-LoadBalancing
2025-11-01T04:36:19.335Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:36:19.343Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:36:19.351Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:36:19.449Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T04:36:19.457Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.9% (6.5 A)
2025-11-01T04:36:20.285Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:36:20.292Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:36:20.300Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=233.5V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:36:20.316Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:36:20.324Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:36:20.335Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:36:20.343Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:36:20.460Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:36:21.269Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:36:31.289Z:INFO:taskMain.c:5996:Socket #1: Active current 6.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T04:36:31.367Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.0% (11.4 A)
2025-11-01T04:36:43.289Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->13.3 due to current limit: Active-LoadBalancing
2025-11-01T04:36:43.488Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.0% (13.2 A)
2025-11-01T04:36:50.332Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=232.4V L3N=231.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:36:50.343Z:USER:taskMaster.c:6720:Socket #1: I1=12.8A I2=12.8A I3=12.8A P=8.9kW Idc=0.7mA
2025-11-01T04:36:55.285Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.1 due to current limit: Active-LoadBalancing
2025-11-01T04:36:55.300Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.0->21.7)
2025-11-01T04:37:07.285Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.5 due to current limit: Active-LoadBalancing
2025-11-01T04:37:07.296Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.7->20.7)
2025-11-01T04:37:07.726Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-11-01T04:37:19.285Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->11.9 due to current limit: Active-LoadBalancing
2025-11-01T04:37:19.296Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.7->19.8)
2025-11-01T04:37:19.843Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.8% (11.9 A)
2025-11-01T04:37:20.253Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:37:20.328Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=231.7V L3N=232.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:37:20.339Z:USER:taskMaster.c:6720:Socket #1: I1=12.1A I2=12.1A I3=12.1A P=8.4kW Idc=0.7mA
2025-11-01T04:37:31.281Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.3 due to current limit: Active-LoadBalancing
2025-11-01T04:37:31.296Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.8->18.8)
2025-11-01T04:37:31.960Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.8% (11.3 A)
2025-11-01T04:37:43.281Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->10.8 due to current limit: Active-LoadBalancing
2025-11-01T04:37:43.292Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->17.9)
2025-11-01T04:37:44.082Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.9% (10.7 A)
2025-11-01T04:37:50.324Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=231.7V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:37:50.335Z:USER:taskMaster.c:6720:Socket #1: I1=10.4A I2=10.4A I3=10.4A P=7.2kW Idc=0.7mA
2025-11-01T04:37:55.281Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->8.6 due to current limit: Active-LoadBalancing
2025-11-01T04:37:55.292Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (17.9->14.4)
2025-11-01T04:37:56.199Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.4% (8.6 A)
2025-11-01T04:38:07.277Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->6.5 due to current limit: Active-LoadBalancing
2025-11-01T04:38:07.292Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.4->10.8)
2025-11-01T04:38:07.304Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.8% (6.5 A)
2025-11-01T04:38:19.277Z:INFO:taskMain.c:5996:Socket #1: Active current 6.5->8.8 due to current limit: Active-LoadBalancing
2025-11-01T04:38:19.417Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.6% (8.8 A)
2025-11-01T04:38:20.320Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=232.8V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:38:20.332Z:USER:taskMaster.c:6720:Socket #1: I1=6.2A I2=6.2A I3=6.1A P=4.2kW Idc=0.7mA
2025-11-01T04:38:31.277Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->11.4 due to current limit: Active-LoadBalancing
2025-11-01T04:38:31.535Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.0% (11.4 A)
2025-11-01T04:38:38.652Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-01T04:38:38.921Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-01T04:38:43.273Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->12.5 due to current limit: Active-LoadBalancing
2025-11-01T04:38:43.656Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-01T04:38:46.218Z:INFO:heap_trace.c:493:free: 69416/160768 (43.2%) min: 43808 (27.2%) alloc #: 197
2025-11-01T04:38:46.230Z:INFO:heap_trace.c:495:fragm: 28.6% 4K: 11.5% free blocks: # 11 largest: 49560
2025-11-01T04:38:50.316Z:USER:taskMaster.c:6684:Socket #1: L1N=231.8V L2N=232.2V L3N=231.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:38:50.332Z:USER:taskMaster.c:6720:Socket #1: I1=12.1A I2=12.1A I3=12.1A P=8.4kW Idc=0.7mA
2025-11-01T04:38:54.367Z:INFO:active_lb.c:308:SMt:(13.0 12.0 16.0)A Free:(3.0 4.0 0.0)A ALB:(15.5 13.9 12.5)A
2025-11-01T04:38:54.468Z:INFO:comFaults.c:482:Reset fault status
2025-11-01T04:38:55.273Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-01T04:38:55.285Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.8->20.5)
2025-11-01T04:39:01.117Z:USER:taskMaster.c:6582:Temperature: 29.5 C
2025-11-01T04:39:07.273Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->11.8 due to current limit: Active-LoadBalancing
2025-11-01T04:39:07.285Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.5->19.6)
2025-11-01T04:39:07.890Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.6% (11.8 A)
2025-11-01T04:39:19.269Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T04:39:19.285Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-01T04:39:20.316Z:USER:taskMaster.c:6684:Socket #1: L1N=231.9V L2N=232.3V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:39:20.328Z:USER:taskMaster.c:6720:Socket #1: I1=11.4A I2=11.4A I3=11.4A P=7.9kW Idc=0.7mA
2025-11-01T04:39:31.269Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T04:39:31.281Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-01T04:39:43.269Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->10.7 due to current limit: Active-LoadBalancing
2025-11-01T04:39:43.281Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->17.9)
2025-11-01T04:39:44.250Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.9% (10.7 A)
2025-11-01T04:39:50.312Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=232.4V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:39:50.324Z:USER:taskMaster.c:6720:Socket #1: I1=10.4A I2=10.4A I3=10.4A P=7.2kW Idc=0.7mA
2025-11-01T04:39:55.265Z:INFO:taskMain.c:5996:Socket #1: Active current 10.7->10.9 due to current limit: Active-LoadBalancing
2025-11-01T04:40:07.265Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.2 due to current limit: Active-LoadBalancing
2025-11-01T04:40:19.265Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->10.2 due to current limit: Active-LoadBalancing
2025-11-01T04:40:19.277Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->16.9)
2025-11-01T04:40:19.593Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.9% (10.1 A)
2025-11-01T04:40:20.308Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=231.6V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:40:20.320Z:USER:taskMaster.c:6720:Socket #1: I1=10.7A I2=10.8A I3=10.7A P=7.5kW Idc=0.7mA
2025-11-01T04:40:31.261Z:INFO:taskMain.c:5996:Socket #1: Active current 10.2->8.0 due to current limit: Active-LoadBalancing
2025-11-01T04:40:31.277Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (16.9->13.3)
2025-11-01T04:40:31.714Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.3% (8.0 A)
2025-11-01T04:40:38.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T04:40:43.261Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->6.3 due to current limit: Active-LoadBalancing
2025-11-01T04:40:43.273Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (13.3->10.4)
2025-11-01T04:40:43.832Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.4% (6.2 A)
2025-11-01T04:40:50.304Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=232.0V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:40:50.316Z:USER:taskMaster.c:6720:Socket #1: I1=6.0A I2=6.1A I3=6.0A P=4.2kW Idc=0.7mA
2025-11-01T04:40:55.261Z:INFO:taskMain.c:5996:Socket #1: Active current 6.3->5.4 due to current limit: Active-LoadBalancing
2025-11-01T04:40:55.273Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (10.4->10.4)
2025-11-01T04:40:55.285Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.39) < minimum current(6.00)
2025-11-01T04:40:55.304Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:40:55.316Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:40:55.328Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:40:55.949Z:INFO:taskMain.c:6499:Socket #1: CPlow 6.3 V
2025-11-01T04:40:56.253Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:40:56.265Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:40:56.312Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T04:40:56.320Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-01T04:40:56.324Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.2/9.3, tag: 04BB
2025-11-01T04:40:56.324Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:41:07.261Z:INFO:taskMain.c:5996:Socket #1: Active current 5.4->3.2 due to current limit: Active-LoadBalancing
2025-11-01T04:41:19.257Z:INFO:taskMain.c:5996:Socket #1: Active current 3.2->4.3 due to current limit: Active-LoadBalancing
2025-11-01T04:41:20.300Z:USER:taskMaster.c:6684:Socket #1: L1N=233.2V L2N=232.5V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:41:20.316Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:41:20.324Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-01T04:41:31.257Z:INFO:taskMain.c:5996:Socket #1: Active current 4.3->5.0 due to current limit: Active-LoadBalancing
2025-11-01T04:41:43.257Z:INFO:taskMain.c:5996:Socket #1: Active current 5.0->5.4 due to current limit: Active-LoadBalancing
2025-11-01T04:41:55.253Z:INFO:taskMain.c:5996:Socket #1: Active current 5.4->5.6 due to current limit: Active-LoadBalancing
2025-11-01T04:42:07.253Z:INFO:taskMain.c:5996:Socket #1: Active current 5.6->9.4 due to current limit: Active-LoadBalancing
2025-11-01T04:42:07.296Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:42:07.308Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:42:07.316Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:42:08.011Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T04:42:08.019Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.6% (9.4 A)
2025-11-01T04:42:08.246Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:42:08.257Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:42:08.265Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=233.2V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:42:08.277Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:42:08.289Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:42:08.296Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:42:08.304Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:42:09.023Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:42:09.261Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:42:19.253Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->14.5 due to current limit: Active-LoadBalancing
2025-11-01T04:42:19.363Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-01T04:42:31.250Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->15.1 due to current limit: Active-LoadBalancing
2025-11-01T04:42:31.480Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.1% (15.1 A)
2025-11-01T04:42:38.292Z:USER:taskMaster.c:6684:Socket #1: L1N=231.6V L2N=231.9V L3N=231.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:42:38.304Z:USER:taskMaster.c:6720:Socket #1: I1=14.7A I2=14.7A I3=14.6A P=10.2kW Idc=0.7mA
2025-11-01T04:42:43.250Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->13.7 due to current limit: Active-LoadBalancing
2025-11-01T04:42:43.261Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->22.8)
2025-11-01T04:42:43.601Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.8% (13.7 A)
2025-11-01T04:42:55.250Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->12.3 due to current limit: Active-LoadBalancing
2025-11-01T04:42:55.261Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.8->20.5)
2025-11-01T04:42:55.718Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.5% (12.3 A)
2025-11-01T04:43:07.246Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->11.4 due to current limit: Active-LoadBalancing
2025-11-01T04:43:07.261Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.5->18.9)
2025-11-01T04:43:07.835Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.9% (11.3 A)
2025-11-01T04:43:08.246Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:43:08.292Z:USER:taskMaster.c:6684:Socket #1: L1N=232.0V L2N=232.2V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:43:08.304Z:USER:taskMaster.c:6720:Socket #1: I1=11.9A I2=12.0A I3=11.9A P=8.3kW Idc=0.7mA
2025-11-01T04:43:19.246Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T04:43:19.257Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T04:43:31.246Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->10.8 due to current limit: Active-LoadBalancing
2025-11-01T04:43:31.257Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.0)
2025-11-01T04:43:32.074Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.0% (10.8 A)
2025-11-01T04:43:38.289Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=232.1V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:43:38.300Z:USER:taskMaster.c:6720:Socket #1: I1=10.5A I2=10.5A I3=10.5A P=7.3kW Idc=0.7mA
2025-11-01T04:43:43.242Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->8.7 due to current limit: Active-LoadBalancing
2025-11-01T04:43:43.257Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.0->14.5)
2025-11-01T04:43:44.191Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.5% (8.7 A)
2025-11-01T04:43:55.242Z:INFO:taskMain.c:5996:Socket #1: Active current 8.7->6.6 due to current limit: Active-LoadBalancing
2025-11-01T04:43:55.253Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.5->10.9)
2025-11-01T04:43:55.300Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.9% (6.5 A)
2025-11-01T04:44:07.242Z:INFO:taskMain.c:5996:Socket #1: Active current 6.6->5.2 due to current limit: Active-LoadBalancing
2025-11-01T04:44:07.253Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (10.9->10.9)
2025-11-01T04:44:07.265Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.24) < minimum current(6.00)
2025-11-01T04:44:07.285Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:44:07.296Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:44:07.304Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:44:07.421Z:INFO:taskMain.c:6499:Socket #1: CPlow 6.3 V
2025-11-01T04:44:08.234Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:44:08.242Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:44:08.285Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.4V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:44:08.296Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-01T04:44:08.304Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-01T04:44:08.312Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-11-01T04:44:08.312Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:44:08.332Z:USER:taskMaster.c:6720:Socket #1: I1=6.2A I2=6.2A I3=6.1A P=4.3kW Idc=0.7mA
2025-11-01T04:44:19.238Z:INFO:taskMain.c:5996:Socket #1: Active current 5.2->6.7 due to current limit: Active-LoadBalancing
2025-11-01T04:44:19.285Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:44:19.292Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:44:19.300Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:44:19.398Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T04:44:20.234Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:44:20.242Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:44:20.250Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=233.8V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:44:20.265Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:44:20.273Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:44:20.285Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:44:20.292Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:44:20.410Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:44:21.250Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:44:31.238Z:INFO:taskMain.c:5996:Socket #1: Active current 6.7->11.7 due to current limit: Active-LoadBalancing
2025-11-01T04:44:31.347Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.5% (11.7 A)
2025-11-01T04:44:43.238Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->13.6 due to current limit: Active-LoadBalancing
2025-11-01T04:44:43.468Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-01T04:44:50.281Z:USER:taskMaster.c:6684:Socket #1: L1N=231.9V L2N=232.5V L3N=232.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:44:50.292Z:USER:taskMaster.c:6720:Socket #1: I1=13.1A I2=13.2A I3=13.1A P=9.2kW Idc=0.7mA
2025-11-01T04:44:55.234Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-01T04:44:55.250Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.6->22.3)
2025-11-01T04:45:07.234Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->12.4 due to current limit: Active-LoadBalancing
2025-11-01T04:45:07.246Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.3->20.7)
2025-11-01T04:45:07.703Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-11-01T04:45:19.234Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->11.5 due to current limit: Active-LoadBalancing
2025-11-01T04:45:19.246Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.7->19.1)
2025-11-01T04:45:19.824Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.1% (11.5 A)
2025-11-01T04:45:20.234Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:45:20.277Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=232.6V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:45:20.289Z:USER:taskMaster.c:6720:Socket #1: I1=12.1A I2=12.1A I3=12.1A P=8.4kW Idc=0.7mA
2025-11-01T04:45:31.230Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->10.9 due to current limit: Active-LoadBalancing
2025-11-01T04:45:31.246Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.1)
2025-11-01T04:45:31.941Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.1% (10.9 A)
2025-11-01T04:45:43.230Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->10.7 due to current limit: Active-LoadBalancing
2025-11-01T04:45:43.242Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.1->17.9)
2025-11-01T04:45:50.273Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=232.0V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:45:50.285Z:USER:taskMaster.c:6720:Socket #1: I1=10.4A I2=10.4A I3=10.3A P=7.2kW Idc=0.7mA
2025-11-01T04:45:55.230Z:INFO:taskMain.c:5996:Socket #1: Active current 10.7->10.8 due to current limit: Active-LoadBalancing
2025-11-01T04:46:07.226Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->8.7 due to current limit: Active-LoadBalancing
2025-11-01T04:46:07.242Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.0->14.4)
2025-11-01T04:46:07.289Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.4% (8.6 A)
2025-11-01T04:46:19.226Z:INFO:taskMain.c:5996:Socket #1: Active current 8.7->6.6 due to current limit: Active-LoadBalancing
2025-11-01T04:46:19.238Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.4->10.9)
2025-11-01T04:46:19.406Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.9% (6.5 A)
2025-11-01T04:46:20.269Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=232.5V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:46:20.281Z:USER:taskMaster.c:6720:Socket #1: I1=8.3A I2=8.3A I3=8.3A P=5.8kW Idc=0.7mA
2025-11-01T04:46:31.226Z:INFO:taskMain.c:5996:Socket #1: Active current 6.6->5.2 due to current limit: Active-LoadBalancing
2025-11-01T04:46:31.238Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (10.9->10.9)
2025-11-01T04:46:31.250Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.22) < minimum current(6.00)
2025-11-01T04:46:31.277Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:46:31.285Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:46:31.296Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:46:31.527Z:INFO:taskMain.c:6499:Socket #1: CPlow 6.3 V
2025-11-01T04:46:32.269Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:46:32.277Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T04:46:32.285Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-01T04:46:32.292Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.2/9.2, tag: 04BB
2025-11-01T04:46:32.292Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:46:32.312Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:46:43.222Z:INFO:taskMain.c:5996:Socket #1: Active current 5.2->6.3 due to current limit: Active-LoadBalancing
2025-11-01T04:46:43.269Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:46:43.277Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:46:43.289Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:46:43.382Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T04:46:44.269Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:46:44.277Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:46:44.285Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.1V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:46:44.300Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:46:44.308Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:46:44.316Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:46:44.328Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:46:44.394Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:46:45.253Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:46:55.222Z:INFO:taskMain.c:5996:Socket #1: Active current 6.3->11.6 due to current limit: Active-LoadBalancing
2025-11-01T04:46:55.351Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.2% (11.5 A)
2025-11-01T04:47:07.222Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->13.8 due to current limit: Active-LoadBalancing
2025-11-01T04:47:07.472Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-01T04:47:14.316Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=232.6V L3N=231.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:47:14.328Z:USER:taskMaster.c:6720:Socket #1: I1=13.5A I2=13.5A I3=13.5A P=9.4kW Idc=0.7mA
2025-11-01T04:47:19.218Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.7 due to current limit: Active-LoadBalancing
2025-11-01T04:47:19.234Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.0->22.8)
2025-11-01T04:47:31.218Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->12.7 due to current limit: Active-LoadBalancing
2025-11-01T04:47:31.230Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.8->21.2)
2025-11-01T04:47:31.710Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.2% (12.7 A)
2025-11-01T04:47:43.218Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->11.8 due to current limit: Active-LoadBalancing
2025-11-01T04:47:43.230Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.2->19.5)
2025-11-01T04:47:43.828Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.5% (11.7 A)
2025-11-01T04:47:44.238Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:47:44.312Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=232.3V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:47:44.324Z:USER:taskMaster.c:6720:Socket #1: I1=12.4A I2=12.4A I3=12.3A P=8.6kW Idc=0.7mA
2025-11-01T04:47:55.214Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.2 due to current limit: Active-LoadBalancing
2025-11-01T04:47:55.230Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->18.6)
2025-11-01T04:47:55.945Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.6% (11.2 A)
2025-11-01T04:48:07.214Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-01T04:48:07.226Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-01T04:48:14.308Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=231.9V L3N=232.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:48:14.320Z:USER:taskMaster.c:6720:Socket #1: I1=10.6A I2=10.6A I3=10.6A P=7.3kW Idc=0.7mA
2025-11-01T04:48:19.214Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->10.7 due to current limit: Active-LoadBalancing
2025-11-01T04:48:19.226Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.3->17.7)
2025-11-01T04:48:20.183Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.7% (10.6 A)
2025-11-01T04:48:31.214Z:INFO:taskMain.c:5996:Socket #1: Active current 10.7->8.5 due to current limit: Active-LoadBalancing
2025-11-01T04:48:31.226Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (17.7->14.2)
2025-11-01T04:48:31.292Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.2% (8.5 A)
2025-11-01T04:48:43.210Z:INFO:taskMain.c:5996:Socket #1: Active current 8.5->6.4 due to current limit: Active-LoadBalancing
2025-11-01T04:48:43.222Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.2->10.6)
2025-11-01T04:48:43.410Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.6% (6.4 A)
2025-11-01T04:48:44.304Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=233.2V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:48:44.316Z:USER:taskMaster.c:6720:Socket #1: I1=8.2A I2=8.2A I3=8.1A P=5.7kW Idc=0.7mA
2025-11-01T04:48:54.304Z:INFO:active_lb.c:308:SMt:(9.0 19.0 13.0)A Free:(7.0 -3.0 3.0)A ALB:(14.4 6.4 10.4)A
2025-11-01T04:48:55.210Z:INFO:taskMain.c:5996:Socket #1: Active current 6.4->5.1 due to current limit: Active-LoadBalancing
2025-11-01T04:48:55.222Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (10.6->10.6)
2025-11-01T04:48:55.234Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.06) < minimum current(6.00)
2025-11-01T04:48:55.253Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:48:55.265Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:48:55.273Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:48:55.531Z:INFO:taskMain.c:6499:Socket #1: CPlow 6.3 V
2025-11-01T04:48:56.253Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:48:56.261Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T04:48:56.269Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-01T04:48:56.277Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.2/9.3, tag: 04BB
2025-11-01T04:48:56.277Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:48:56.296Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:49:07.210Z:INFO:taskMain.c:5996:Socket #1: Active current 5.1->6.6 due to current limit: Active-LoadBalancing
2025-11-01T04:49:07.253Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:49:07.265Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:49:07.273Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:49:07.367Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T04:49:08.152Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:49:08.164Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:49:08.171Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.1V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:49:08.183Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:49:08.195Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:49:08.203Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:49:08.210Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:49:08.378Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:49:09.148Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:49:19.207Z:INFO:taskMain.c:5996:Socket #1: Active current 6.6->11.7 due to current limit: Active-LoadBalancing
2025-11-01T04:49:19.246Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.4% (11.6 A)
2025-11-01T04:49:31.207Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->13.5 due to current limit: Active-LoadBalancing
2025-11-01T04:49:31.367Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-01T04:49:38.199Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=232.9V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:49:38.210Z:USER:taskMaster.c:6720:Socket #1: I1=13.1A I2=13.1A I3=13.0A P=9.1kW Idc=0.7mA
2025-11-01T04:49:43.207Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-11-01T04:49:43.218Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.4->22.1)
2025-11-01T04:49:55.203Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->12.7 due to current limit: Active-LoadBalancing
2025-11-01T04:49:55.214Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.1->21.1)
2025-11-01T04:49:55.605Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.1% (12.7 A)
2025-11-01T04:50:07.203Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.1 due to current limit: Active-LoadBalancing
2025-11-01T04:50:07.214Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.1->20.1)
2025-11-01T04:50:07.722Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.1% (12.1 A)
2025-11-01T04:50:08.132Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:50:08.195Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=233.0V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:50:08.210Z:USER:taskMaster.c:6720:Socket #1: I1=12.3A I2=12.3A I3=12.3A P=8.6kW Idc=0.7mA
2025-11-01T04:50:19.203Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->11.5 due to current limit: Active-LoadBalancing
2025-11-01T04:50:19.214Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.1->19.1)
2025-11-01T04:50:19.839Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.1% (11.5 A)
2025-11-01T04:50:31.199Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->10.7 due to current limit: Active-LoadBalancing
2025-11-01T04:50:31.214Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->17.8)
2025-11-01T04:50:31.960Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.8% (10.7 A)
2025-11-01T04:50:38.195Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=232.2V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:50:38.207Z:USER:taskMaster.c:6720:Socket #1: I1=10.3A I2=10.3A I3=10.2A P=7.1kW Idc=0.7mA
2025-11-01T04:50:43.199Z:INFO:taskMain.c:5996:Socket #1: Active current 10.7->8.1 due to current limit: Active-LoadBalancing
2025-11-01T04:50:43.210Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (17.8->13.5)
2025-11-01T04:50:44.078Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.5% (8.1 A)
2025-11-01T04:50:55.199Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->6.0 due to current limit: Active-LoadBalancing
2025-11-01T04:50:55.210Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (13.5->10.0)
2025-11-01T04:50:56.199Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.0% (6.0 A)
2025-11-01T04:51:07.195Z:INFO:taskMain.c:5996:Socket #1: Active current 6.0->5.2 due to current limit: Active-LoadBalancing
2025-11-01T04:51:07.207Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (10.0->10.0)
2025-11-01T04:51:07.222Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.22) < minimum current(6.00)
2025-11-01T04:51:07.242Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:51:07.253Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:51:07.261Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:51:07.304Z:INFO:taskMain.c:6499:Socket #1: CPlow 6.3 V
2025-11-01T04:51:08.191Z:USER:taskMaster.c:6684:Socket #1: L1N=233.2V L2N=233.6V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:51:08.203Z:USER:taskMaster.c:6720:Socket #1: I1=6.0A I2=6.0A I3=6.0A P=4.2kW Idc=0.7mA
2025-11-01T04:51:08.238Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:51:08.250Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-01T04:51:08.257Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-01T04:51:08.265Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.2, tag: 04BB
2025-11-01T04:51:08.265Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:51:08.285Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:51:19.195Z:INFO:taskMain.c:5996:Socket #1: Active current 5.2->6.7 due to current limit: Active-LoadBalancing
2025-11-01T04:51:19.238Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:51:19.250Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:51:19.257Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:51:19.355Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T04:51:19.363Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.2% (6.7 A)
2025-11-01T04:51:20.238Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:51:20.250Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:51:20.257Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.4V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:51:20.269Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:51:20.281Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:51:20.289Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:51:20.296Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:51:20.363Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:51:21.234Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:51:31.195Z:INFO:taskMain.c:5996:Socket #1: Active current 6.7->12.0 due to current limit: Active-LoadBalancing
2025-11-01T04:51:31.332Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.9% (11.9 A)
2025-11-01T04:51:43.191Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->13.8 due to current limit: Active-LoadBalancing
2025-11-01T04:51:43.453Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-01T04:51:50.285Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=232.8V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:51:50.296Z:USER:taskMaster.c:6720:Socket #1: I1=13.5A I2=13.5A I3=13.5A P=9.4kW Idc=0.7mA
2025-11-01T04:51:55.191Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.7 due to current limit: Active-LoadBalancing
2025-11-01T04:51:55.203Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.0->22.8)
2025-11-01T04:52:07.191Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->12.7 due to current limit: Active-LoadBalancing
2025-11-01T04:52:07.203Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.8->21.1)
2025-11-01T04:52:07.691Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.1% (12.7 A)
2025-11-01T04:52:19.187Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->11.7 due to current limit: Active-LoadBalancing
2025-11-01T04:52:19.203Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.1->19.5)
2025-11-01T04:52:19.808Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.5% (11.7 A)
2025-11-01T04:52:20.218Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:52:20.281Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=232.8V L3N=232.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:52:20.296Z:USER:taskMaster.c:6720:Socket #1: I1=12.3A I2=12.3A I3=12.3A P=8.6kW Idc=0.7mA
2025-11-01T04:52:31.187Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.2 due to current limit: Active-LoadBalancing
2025-11-01T04:52:31.199Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->18.6)
2025-11-01T04:52:31.925Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.6% (11.2 A)
2025-11-01T04:52:43.187Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-01T04:52:43.199Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-01T04:52:50.281Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=232.2V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:52:50.292Z:USER:taskMaster.c:6720:Socket #1: I1=10.6A I2=10.6A I3=10.5A P=7.4kW Idc=0.7mA
2025-11-01T04:52:55.183Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->9.3 due to current limit: Active-LoadBalancing
2025-11-01T04:52:55.199Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.3->15.4)
2025-11-01T04:52:56.164Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.4% (9.2 A)
2025-11-01T04:53:07.183Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->7.1 due to current limit: Active-LoadBalancing
2025-11-01T04:53:07.195Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.4->11.8)
2025-11-01T04:53:07.273Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.8% (7.1 A)
2025-11-01T04:53:19.183Z:INFO:taskMain.c:5996:Socket #1: Active current 7.1->5.4 due to current limit: Active-LoadBalancing
2025-11-01T04:53:19.195Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.8->11.8)
2025-11-01T04:53:19.207Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.35) < minimum current(6.00)
2025-11-01T04:53:19.226Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:53:19.238Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:53:19.246Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:53:19.390Z:INFO:taskMain.c:6499:Socket #1: CPlow 6.3 V
2025-11-01T04:53:20.226Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:53:20.234Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T04:53:20.242Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-01T04:53:20.250Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.2/9.2, tag: 04BB
2025-11-01T04:53:20.250Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:53:20.269Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:53:20.277Z:USER:taskMaster.c:6684:Socket #1: L1N=233.2V L2N=233.7V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:53:20.292Z:USER:taskMaster.c:6720:Socket #1: I1=6.7A I2=6.7A I3=6.7A P=4.6kW Idc=0.7mA
2025-11-01T04:53:31.179Z:INFO:taskMain.c:5996:Socket #1: Active current 5.4->6.4 due to current limit: Active-LoadBalancing
2025-11-01T04:53:31.226Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:53:31.234Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:53:31.246Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:53:31.339Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T04:53:31.347Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.6% (6.4 A)
2025-11-01T04:53:32.125Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:53:32.132Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:53:32.144Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.4V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:53:32.156Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:53:32.167Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:53:32.175Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:53:32.183Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:53:32.351Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:53:33.140Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:53:43.179Z:INFO:taskMain.c:5996:Socket #1: Active current 6.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T04:53:43.238Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.4% (11.6 A)
2025-11-01T04:53:55.179Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->13.5 due to current limit: Active-LoadBalancing
2025-11-01T04:53:55.359Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.5% (13.5 A)
2025-11-01T04:54:01.472Z:USER:taskMaster.c:6582:Temperature: 29.5 C
2025-11-01T04:54:02.171Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=232.7V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:54:02.187Z:USER:taskMaster.c:6720:Socket #1: I1=13.2A I2=13.2A I3=13.2A P=9.2kW Idc=0.7mA
2025-11-01T04:54:07.175Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.8 due to current limit: Active-LoadBalancing
2025-11-01T04:54:19.175Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->12.8 due to current limit: Active-LoadBalancing
2025-11-01T04:54:19.187Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.9->21.3)
2025-11-01T04:54:19.597Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.3% (12.8 A)
2025-11-01T04:54:31.175Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->11.8 due to current limit: Active-LoadBalancing
2025-11-01T04:54:31.187Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.3->19.6)
2025-11-01T04:54:31.714Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.6% (11.8 A)
2025-11-01T04:54:32.125Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:54:32.167Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=232.7V L3N=232.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:54:32.179Z:USER:taskMaster.c:6720:Socket #1: I1=12.3A I2=12.4A I3=12.3A P=8.6kW Idc=0.7mA
2025-11-01T04:54:43.171Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.2 due to current limit: Active-LoadBalancing
2025-11-01T04:54:43.187Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->18.7)
2025-11-01T04:54:43.832Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.7% (11.2 A)
2025-11-01T04:54:55.171Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.1 due to current limit: Active-LoadBalancing
2025-11-01T04:54:55.183Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-01T04:55:02.164Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=232.1V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:55:02.179Z:USER:taskMaster.c:6720:Socket #1: I1=10.7A I2=10.7A I3=10.7A P=7.4kW Idc=0.7mA
2025-11-01T04:55:07.171Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->10.3 due to current limit: Active-LoadBalancing
2025-11-01T04:55:07.183Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.4->17.2)
2025-11-01T04:55:08.070Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.2% (10.3 A)
2025-11-01T04:55:19.167Z:INFO:taskMain.c:5996:Socket #1: Active current 10.3->7.8 due to current limit: Active-LoadBalancing
2025-11-01T04:55:19.183Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (17.2->12.9)
2025-11-01T04:55:19.195Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.9% (7.7 A)
2025-11-01T04:55:31.167Z:INFO:taskMain.c:5996:Socket #1: Active current 7.8->5.6 due to current limit: Active-LoadBalancing
2025-11-01T04:55:31.179Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (12.9->12.9)
2025-11-01T04:55:31.191Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.64) < minimum current(6.00)
2025-11-01T04:55:31.210Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:55:31.222Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:55:31.234Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:55:31.308Z:INFO:taskMain.c:6499:Socket #1: CPlow 6.3 V
2025-11-01T04:55:32.164Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.5V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:55:32.175Z:USER:taskMaster.c:6720:Socket #1: I1=7.4A I2=7.4A I3=7.3A P=5.1kW Idc=0.7mA
2025-11-01T04:55:32.210Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:55:32.222Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T04:55:32.230Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-01T04:55:32.234Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.2/9.2, tag: 04BB
2025-11-01T04:55:32.234Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:55:32.253Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:55:38.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T04:55:43.167Z:INFO:taskMain.c:5996:Socket #1: Active current 5.6->6.2 due to current limit: Active-LoadBalancing
2025-11-01T04:55:43.210Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:55:43.222Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:55:43.230Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:55:43.328Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T04:55:43.335Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.3% (6.2 A)
2025-11-01T04:55:44.109Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:55:44.121Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:55:44.128Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.3V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:55:44.140Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:55:44.152Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:55:44.160Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:55:44.171Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:55:44.335Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:55:45.128Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:55:55.167Z:INFO:taskMain.c:5996:Socket #1: Active current 6.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T04:55:55.226Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.9% (11.3 A)
2025-11-01T04:56:07.164Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->15.6 due to current limit: Active-LoadBalancing
2025-11-01T04:56:07.343Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.9% (15.5 A)
2025-11-01T04:56:14.156Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=232.5V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:56:14.171Z:USER:taskMaster.c:6720:Socket #1: I1=15.1A I2=15.2A I3=15.1A P=10.5kW Idc=0.7mA
2025-11-01T04:56:19.164Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.9 due to current limit: ChargingProfile
2025-11-01T04:56:19.207Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-01T04:56:19.464Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-01T04:56:31.164Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.0 due to current limit: Active-LoadBalancing
2025-11-01T04:56:31.175Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->25.0)
2025-11-01T04:56:31.207Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:56:31.582Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.0% (15.0 A)
2025-11-01T04:56:43.160Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->13.2 due to current limit: Active-LoadBalancing
2025-11-01T04:56:43.171Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->22.0)
2025-11-01T04:56:43.699Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.0% (13.2 A)
2025-11-01T04:56:44.109Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:56:44.156Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=232.4V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:56:44.167Z:USER:taskMaster.c:6720:Socket #1: I1=14.6A I2=14.7A I3=14.6A P=10.2kW Idc=0.7mA
2025-11-01T04:56:55.160Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->11.9 due to current limit: Active-LoadBalancing
2025-11-01T04:56:55.171Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.0->19.7)
2025-11-01T04:56:55.820Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.7% (11.8 A)
2025-11-01T04:57:07.160Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.3 due to current limit: Active-LoadBalancing
2025-11-01T04:57:07.171Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.7->18.8)
2025-11-01T04:57:07.937Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.8% (11.3 A)
2025-11-01T04:57:14.152Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=232.2V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:57:14.164Z:USER:taskMaster.c:6720:Socket #1: I1=10.9A I2=10.9A I3=10.9A P=7.6kW Idc=0.7mA
2025-11-01T04:57:19.156Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-01T04:57:19.167Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-01T04:57:31.156Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->10.4 due to current limit: Active-LoadBalancing
2025-11-01T04:57:31.167Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->17.3)
2025-11-01T04:57:31.179Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.3% (10.4 A)
2025-11-01T04:57:43.156Z:INFO:taskMain.c:5996:Socket #1: Active current 10.4->7.8 due to current limit: Active-LoadBalancing
2025-11-01T04:57:43.167Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (17.3->13.0)
2025-11-01T04:57:43.292Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.0% (7.8 A)
2025-11-01T04:57:44.148Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=232.9V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:57:44.160Z:USER:taskMaster.c:6720:Socket #1: I1=10.0A I2=10.0A I3=9.9A P=6.9kW Idc=0.7mA
2025-11-01T04:57:55.152Z:INFO:taskMain.c:5996:Socket #1: Active current 7.8->5.7 due to current limit: Active-LoadBalancing
2025-11-01T04:57:55.164Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (13.0->13.0)
2025-11-01T04:57:55.179Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.73) < minimum current(6.00)
2025-11-01T04:57:55.195Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T04:57:55.207Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-01T04:57:55.218Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T04:57:55.414Z:INFO:taskMain.c:6499:Socket #1: CPlow 6.3 V
2025-11-01T04:57:56.148Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T04:57:56.156Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T04:57:56.203Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T04:57:56.210Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-01T04:57:56.218Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.2/9.3, tag: 04BB
2025-11-01T04:57:56.218Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T04:58:07.152Z:INFO:taskMain.c:5996:Socket #1: Active current 5.7->6.2 due to current limit: Active-LoadBalancing
2025-11-01T04:58:07.195Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T04:58:07.207Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T04:58:07.214Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T04:58:07.312Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T04:58:07.320Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.3% (6.2 A)
2025-11-01T04:58:08.144Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T04:58:08.156Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T04:58:08.164Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=234.2V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:58:08.175Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T04:58:08.187Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T04:58:08.195Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T04:58:08.207Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T04:58:08.320Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T04:58:09.132Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T04:58:09.507Z:WARNING:protocolP1.c:505:P1 Device failure: Read CRC Error.
2025-11-01T04:58:19.527Z:USER:protocolP1.c:539:P1 Communications Recovered
2025-11-01T04:58:19.550Z:INFO:taskMain.c:5996:Socket #1: Active current 6.2->11.5 due to current limit: Active-LoadBalancing
2025-11-01T04:58:20.242Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.2% (11.5 A)
2025-11-01T04:58:31.550Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->13.8 due to current limit: Active-LoadBalancing
2025-11-01T04:58:32.359Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.9% (13.7 A)
2025-11-01T04:58:38.191Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=232.8V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:58:38.203Z:USER:taskMaster.c:6720:Socket #1: I1=13.3A I2=13.4A I3=13.3A P=9.3kW Idc=0.7mA
2025-11-01T04:58:43.546Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.6 due to current limit: Active-LoadBalancing
2025-11-01T04:58:43.562Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.9->22.6)
2025-11-01T04:58:54.242Z:INFO:active_lb.c:308:SMt:(14.0 15.0 18.0)A Free:(2.0 1.0 -2.0)A ALB:(17.6 15.4 13.6)A
2025-11-01T04:58:55.546Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->12.6 due to current limit: Active-LoadBalancing
2025-11-01T04:58:55.558Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.6->21.0)
2025-11-01T04:58:55.585Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-11-01T04:59:07.546Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->11.7 due to current limit: Active-LoadBalancing
2025-11-01T04:59:07.558Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.0->19.4)
2025-11-01T04:59:07.707Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.4% (11.6 A)
2025-11-01T04:59:08.117Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T04:59:08.191Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=233.0V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:59:08.203Z:USER:taskMaster.c:6720:Socket #1: I1=12.3A I2=12.3A I3=12.3A P=8.6kW Idc=0.7mA
2025-11-01T04:59:19.542Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.1 due to current limit: Active-LoadBalancing
2025-11-01T04:59:19.558Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->18.5)
2025-11-01T04:59:19.824Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.5% (11.1 A)
2025-11-01T04:59:31.542Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.0 due to current limit: Active-LoadBalancing
2025-11-01T04:59:31.554Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->18.2)
2025-11-01T04:59:38.187Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=233.0V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T04:59:38.199Z:USER:taskMaster.c:6720:Socket #1: I1=10.6A I2=10.6A I3=10.6A P=7.4kW Idc=0.7mA
2025-11-01T04:59:43.542Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-01T04:59:55.539Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:00:07.539Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:00:08.183Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=233.0V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T05:00:08.195Z:USER:taskMaster.c:6720:Socket #1: I1=11.1A I2=11.1A I3=11.1A P=7.7kW Idc=0.7mA
2025-11-01T05:00:19.539Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:00:19.550Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T05:00:31.535Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:00:31.550Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.9)
2025-11-01T05:00:38.179Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=232.8V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T05:00:38.191Z:USER:taskMaster.c:6720:Socket #1: I1=10.9A I2=11.0A I3=10.9A P=7.6kW Idc=0.7mA
2025-11-01T05:00:43.535Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:00:43.546Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T05:00:45.433Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-01T05:00:45.441Z:INFO:db_chargingprofi:26: socket 0
2025-11-01T05:00:45.449Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-01T05:00:45.457Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-01T05:00:45.464Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-01T05:00:45.476Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-01T05:00:45.484Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-01T05:00:45.496Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-01T05:00:45.503Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-01T05:00:45.511Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-01T05:00:45.519Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-01T05:00:45.527Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-01T05:00:45.535Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-01T05:00:45.542Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-01T05:00:45.550Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-01T05:00:45.562Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-01T05:00:45.570Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-01T05:00:45.578Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-01T05:00:45.585Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-01T05:00:45.597Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-01T05:00:45.601Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-01T05:00:45.613Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-01T05:00:45.621Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-01T05:00:55.535Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:01:07.531Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:01:08.175Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=232.6V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T05:01:08.187Z:USER:taskMaster.c:6720:Socket #1: I1=11.1A I2=11.1A I3=11.1A P=7.7kW Idc=0.7mA
2025-11-01T05:01:19.531Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.9 due to current limit: Active-LoadBalancing
2025-11-01T05:01:31.531Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:01:31.542Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.8->19.5)
2025-11-01T05:01:38.175Z:USER:taskMaster.c:6684:Socket #1: L1N=231.4V L2N=232.1V L3N=231.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T05:01:38.187Z:USER:taskMaster.c:6720:Socket #1: I1=11.3A I2=11.4A I3=11.3A P=7.9kW Idc=0.7mA
2025-11-01T05:01:43.527Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:01:43.542Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-01T05:01:55.527Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:01:55.539Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-01T05:02:07.527Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:02:07.539Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.7)
2025-11-01T05:02:08.171Z:USER:taskMaster.c:6684:Socket #1: L1N=231.3V L2N=231.8V L3N=231.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T05:02:08.183Z:USER:taskMaster.c:6720:Socket #1: I1=11.0A I2=11.0A I3=11.0A P=7.6kW Idc=0.7mA
2025-11-01T05:02:19.527Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.1 due to current limit: Active-LoadBalancing
2025-11-01T05:02:19.539Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-01T05:02:31.523Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:02:38.167Z:USER:taskMaster.c:6684:Socket #1: L1N=231.0V L2N=231.5V L3N=231.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T05:02:38.179Z:USER:taskMaster.c:6720:Socket #1: I1=10.8A I2=10.9A I3=10.8A P=7.5kW Idc=0.7mA
2025-11-01T05:02:43.523Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:02:55.523Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:03:07.519Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:03:07.531Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-01T05:03:08.164Z:USER:taskMaster.c:6684:Socket #1: L1N=230.7V L2N=231.3V L3N=230.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T05:03:08.175Z:USER:taskMaster.c:6720:Socket #1: I1=11.4A I2=11.4A I3=11.3A P=7.9kW Idc=0.7mA
2025-11-01T05:03:08.187Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-01T05:03:19.519Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:03:31.519Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:03:31.531Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-01T05:03:43.515Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:03:43.527Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-01T05:03:55.515Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:03:55.527Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-01T05:04:07.515Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-01T05:04:07.527Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-01T05:04:19.511Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->10.9 due to current limit: Active-LoadBalancing
2025-11-01T05:04:19.527Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.4->18.1)
2025-11-01T05:04:31.511Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.1 due to current limit: Active-LoadBalancing
2025-11-01T05:04:43.511Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:04:55.507Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:05:07.507Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:05:07.519Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-01T05:05:19.507Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:05:19.519Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-01T05:05:31.503Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-01T05:05:31.519Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-01T05:05:43.503Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->10.9 due to current limit: Active-LoadBalancing
2025-11-01T05:05:43.515Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.4->18.1)
2025-11-01T05:05:55.503Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.1 due to current limit: Active-LoadBalancing
2025-11-01T05:06:07.500Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:06:19.500Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:06:31.500Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:06:31.511Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-01T05:06:43.496Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:06:43.511Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-01T05:06:55.496Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-01T05:06:55.507Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-01T05:07:07.496Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:07:19.492Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:07:31.492Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:07:43.492Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:07:43.503Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-01T05:07:55.488Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:07:55.503Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-01T05:08:07.488Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:08:07.500Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-01T05:08:19.488Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-01T05:08:19.500Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-01T05:08:31.484Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:08:43.484Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:08:54.179Z:INFO:active_lb.c:308:SMt:(11.0 13.0 15.0)A Free:(5.0 3.0 1.0)A ALB:(15.6 14.3 11.5)A
2025-11-01T05:08:55.484Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:09:01.878Z:USER:taskMaster.c:6582:Temperature: 29.8 C
2025-11-01T05:09:07.480Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:09:07.496Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-01T05:09:19.480Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:09:19.492Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-01T05:09:31.480Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:09:31.492Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-01T05:09:43.480Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-01T05:09:43.492Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-01T05:09:55.476Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:10:07.476Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:10:19.476Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:10:31.472Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:10:31.484Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-01T05:10:38.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T05:10:43.472Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:10:43.484Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-01T05:10:55.472Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:10:55.484Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-01T05:11:07.468Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-01T05:11:07.480Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-01T05:11:19.468Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->10.9 due to current limit: Active-LoadBalancing
2025-11-01T05:11:19.480Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.4->18.2)
2025-11-01T05:11:31.468Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:11:43.464Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:11:55.464Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:12:07.464Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:12:19.460Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:12:19.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.7->19.4)
2025-11-01T05:12:31.460Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:12:31.472Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T05:12:43.460Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:12:43.472Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-01T05:12:55.457Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-01T05:12:55.472Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-01T05:13:07.457Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:13:19.457Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:13:31.453Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:13:43.453Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:13:43.464Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-01T05:13:55.453Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:13:55.464Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.9)
2025-11-01T05:14:07.449Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:14:07.464Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T05:14:19.449Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-01T05:14:19.460Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-01T05:14:31.449Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:14:43.445Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:14:55.445Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:15:07.445Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:15:07.457Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T05:15:19.441Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:15:19.457Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-01T05:15:31.441Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-01T05:15:31.453Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-01T05:15:43.441Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:15:55.437Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:16:07.437Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:16:19.437Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->12.0 due to current limit: Active-LoadBalancing
2025-11-01T05:16:31.433Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:16:31.449Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.0->19.7)
2025-11-01T05:16:43.433Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:16:43.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.7->19.4)
2025-11-01T05:16:55.433Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:16:55.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T05:17:07.429Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:17:07.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-01T05:17:19.429Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:17:19.441Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-01T05:17:31.429Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-01T05:17:31.441Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->18.3)
2025-11-01T05:17:43.429Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:17:55.425Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:18:07.425Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:18:08.070Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.0V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T05:18:08.082Z:USER:taskMaster.c:6720:Socket #1: I1=11.1A I2=11.1A I3=11.1A P=7.8kW Idc=0.7mA
2025-11-01T05:18:19.425Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.9 due to current limit: Active-LoadBalancing
2025-11-01T05:18:31.421Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:18:31.433Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.8->19.5)
2025-11-01T05:18:43.421Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:18:43.433Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.3)
2025-11-01T05:18:54.113Z:INFO:active_lb.c:308:SMt:(12.0 13.0 16.0)A Free:(4.0 3.0 0.0)A ALB:(15.6 14.9 11.6)A
2025-11-01T05:18:55.421Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:18:55.433Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.9)
2025-11-01T05:19:07.417Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:19:07.429Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T05:19:19.417Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-01T05:19:19.429Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-01T05:19:31.417Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:19:43.414Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:19:55.414Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:20:07.414Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:20:07.425Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-01T05:20:19.410Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:20:19.425Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-01T05:20:31.410Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:20:31.421Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T05:20:43.410Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:20:55.406Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:21:07.406Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:21:07.417Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T05:21:19.406Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:21:19.417Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-01T05:21:31.402Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:21:31.417Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.6)
2025-11-01T05:21:43.402Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:21:55.402Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:22:07.398Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:22:19.398Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->12.0 due to current limit: Active-LoadBalancing
2025-11-01T05:22:31.398Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:22:31.410Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.0->19.7)
2025-11-01T05:22:43.394Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:22:43.410Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.7->19.4)
2025-11-01T05:22:55.394Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:22:55.406Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T05:23:07.394Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:23:07.406Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-01T05:23:19.390Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:23:19.406Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.6)
2025-11-01T05:23:31.390Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-01T05:23:31.402Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-01T05:23:43.390Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:23:55.386Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:24:02.234Z:USER:taskMaster.c:6582:Temperature: 30.0 C
2025-11-01T05:24:07.386Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:24:19.386Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.9 due to current limit: Active-LoadBalancing
2025-11-01T05:24:31.382Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:24:31.398Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.9->19.6)
2025-11-01T05:24:43.382Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:24:43.394Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-01T05:24:55.382Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:24:55.394Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.9)
2025-11-01T05:25:07.378Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:25:07.394Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T05:25:19.378Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-01T05:25:19.390Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-01T05:25:31.378Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:25:38.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T05:25:43.378Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:25:55.375Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:26:07.375Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:26:07.386Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-01T05:26:19.375Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:26:19.386Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-01T05:26:31.371Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:26:31.382Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T05:26:43.371Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:26:55.371Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:27:07.367Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:27:07.378Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.2)
2025-11-01T05:27:19.367Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:27:19.378Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-01T05:27:31.367Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:27:31.378Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T05:27:43.363Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:27:55.363Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:28:07.363Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:28:07.375Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.2)
2025-11-01T05:28:19.359Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:28:19.375Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-01T05:28:31.359Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:28:31.371Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T05:28:43.359Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:28:54.050Z:INFO:active_lb.c:308:SMt:(12.0 12.0 15.0)A Free:(4.0 4.0 1.0)A ALB:(14.3 14.6 11.4)A
2025-11-01T05:28:55.355Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:29:07.355Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:29:07.367Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.2)
2025-11-01T05:29:19.355Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:29:19.367Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-01T05:29:31.351Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:29:31.367Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T05:29:43.351Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:29:55.351Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:30:07.347Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:30:07.363Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T05:30:19.347Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:30:31.347Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:30:31.359Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-01T05:30:43.343Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:30:55.343Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:30:55.355Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.2)
2025-11-01T05:31:07.343Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:31:07.355Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-01T05:31:19.339Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:31:19.355Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.7)
2025-11-01T05:31:31.339Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-01T05:31:31.351Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-01T05:31:43.339Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:31:55.335Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:32:07.335Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:32:19.335Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.9 due to current limit: Active-LoadBalancing
2025-11-01T05:32:31.332Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->12.1 due to current limit: Active-LoadBalancing
2025-11-01T05:32:43.332Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->11.9 due to current limit: Active-LoadBalancing
2025-11-01T05:32:43.343Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.2->19.8)
2025-11-01T05:32:55.332Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:32:55.343Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.8->19.5)
2025-11-01T05:33:07.328Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:33:07.343Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-01T05:33:07.972Z:USER:taskMaster.c:6684:Socket #1: L1N=233.4V L2N=233.7V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T05:33:07.984Z:USER:taskMaster.c:6720:Socket #1: I1=11.3A I2=11.4A I3=11.3A P=7.9kW Idc=0.7mA
2025-11-01T05:33:19.328Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:33:19.339Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-01T05:33:31.328Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:33:31.339Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.7)
2025-11-01T05:33:43.328Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.1 due to current limit: Active-LoadBalancing
2025-11-01T05:33:43.339Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-01T05:33:55.324Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:34:07.324Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:34:19.324Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:34:31.320Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.9 due to current limit: Active-LoadBalancing
2025-11-01T05:34:43.320Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->12.1 due to current limit: Active-LoadBalancing
2025-11-01T05:34:55.320Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->11.9 due to current limit: Active-LoadBalancing
2025-11-01T05:34:55.332Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.2->19.9)
2025-11-01T05:35:07.316Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:35:07.328Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.9->19.6)
2025-11-01T05:35:19.316Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:35:19.328Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-01T05:35:31.316Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:35:31.328Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-01T05:35:43.312Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:35:43.328Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-01T05:35:55.312Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:36:07.312Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:36:19.308Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.9 due to current limit: Active-LoadBalancing
2025-11-01T05:36:31.308Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->12.1 due to current limit: Active-LoadBalancing
2025-11-01T05:36:43.308Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->11.9 due to current limit: Active-LoadBalancing
2025-11-01T05:36:43.320Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.1->19.8)
2025-11-01T05:36:55.304Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:36:55.320Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.8->19.5)
2025-11-01T05:37:07.304Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:37:07.316Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-01T05:37:19.304Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:37:19.316Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->19.0)
2025-11-01T05:37:31.300Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:37:31.316Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-01T05:37:43.300Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.1 due to current limit: Active-LoadBalancing
2025-11-01T05:37:43.312Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-01T05:37:55.300Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:38:07.296Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:38:19.296Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:38:31.296Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->12.0 due to current limit: Active-LoadBalancing
2025-11-01T05:38:43.292Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:38:43.308Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.0->19.7)
2025-11-01T05:38:53.988Z:INFO:active_lb.c:308:SMt:(12.0 13.0 16.0)A Free:(4.0 3.0 0.0)A ALB:(15.9 14.9 11.8)A
2025-11-01T05:38:55.292Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:38:55.304Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.7->19.4)
2025-11-01T05:39:02.636Z:USER:taskMaster.c:6582:Temperature: 30.1 C
2025-11-01T05:39:07.292Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:39:07.304Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T05:39:19.289Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:39:19.304Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-01T05:39:31.289Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-01T05:39:31.300Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-01T05:39:43.289Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:39:55.285Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:40:07.285Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:40:19.285Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:40:19.296Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.3)
2025-11-01T05:40:31.281Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:40:31.296Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-01T05:40:38.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T05:40:43.281Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:40:43.292Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-01T05:40:55.281Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:41:07.277Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:41:19.277Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:41:19.289Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-01T05:41:31.277Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:41:31.289Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-01T05:41:43.277Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:41:43.289Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T05:41:55.273Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:42:07.273Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:42:19.273Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:42:31.269Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:42:31.281Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.7->19.4)
2025-11-01T05:42:43.269Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:42:43.281Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T05:42:55.269Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:43:07.265Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:43:07.277Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-01T05:43:19.265Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:43:19.277Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->19.0)
2025-11-01T05:43:31.265Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:43:31.277Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-01T05:43:43.261Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:43:55.261Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:43:55.273Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-01T05:44:07.261Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-01T05:44:07.273Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-01T05:44:19.257Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:44:31.257Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:44:43.257Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:44:55.253Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:44:55.269Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-01T05:45:07.253Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:45:07.265Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-01T05:45:19.253Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:45:19.265Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-01T05:45:31.250Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-01T05:45:31.265Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.5)
2025-11-01T05:45:43.250Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:45:55.250Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:46:07.246Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:46:19.246Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:46:19.257Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.7->19.4)
2025-11-01T05:46:31.246Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:46:31.257Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T05:46:43.242Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:46:43.257Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-01T05:46:55.242Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-01T05:46:55.253Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-01T05:47:07.242Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:47:19.238Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:47:31.238Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:47:43.238Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:47:43.250Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-01T05:47:55.234Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:47:55.250Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-01T05:48:07.234Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:48:07.246Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-01T05:48:07.878Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=233.1V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T05:48:07.890Z:USER:taskMaster.c:6720:Socket #1: I1=11.1A I2=11.1A I3=11.1A P=7.7kW Idc=0.7mA
2025-11-01T05:48:19.234Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-01T05:48:19.246Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.5)
2025-11-01T05:48:31.230Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:48:43.230Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:48:53.921Z:INFO:active_lb.c:308:SMt:(11.0 13.0 15.0)A Free:(5.0 3.0 1.0)A ALB:(15.6 13.8 11.6)A
2025-11-01T05:48:55.230Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:49:07.226Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:49:07.242Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-01T05:49:19.226Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:49:19.238Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-01T05:49:31.226Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:49:31.238Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-01T05:49:43.226Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-01T05:49:43.238Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.5)
2025-11-01T05:49:55.222Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:50:07.222Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:50:19.222Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-01T05:50:31.218Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:50:31.230Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-01T05:50:43.218Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:50:43.230Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.9)
2025-11-01T05:50:55.218Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:50:55.230Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T05:51:07.214Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:51:19.214Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:51:31.214Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:51:31.226Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.2)
2025-11-01T05:51:43.210Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:51:43.222Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-01T05:51:55.210Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:51:55.222Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T05:52:07.210Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:52:19.207Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:52:31.207Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:52:31.218Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T05:52:43.207Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:52:43.218Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-01T05:52:55.203Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:52:55.218Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.6)
2025-11-01T05:53:07.203Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:53:19.203Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:53:31.199Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:53:31.214Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T05:53:43.199Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:53:43.210Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.9)
2025-11-01T05:53:55.199Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:53:55.210Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T05:54:03.042Z:USER:taskMaster.c:6582:Temperature: 30.5 C
2025-11-01T05:54:07.195Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:54:19.195Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:54:31.195Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:54:31.207Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.2)
2025-11-01T05:54:43.191Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:54:43.207Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-01T05:54:55.191Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:54:55.203Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T05:55:07.191Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:55:19.187Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:55:31.187Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:55:31.199Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.2)
2025-11-01T05:55:38.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T05:55:43.187Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:55:43.199Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-01T05:55:55.183Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:55:55.199Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T05:56:07.183Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:56:19.183Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:56:31.179Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:56:31.195Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T05:56:43.179Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:56:43.191Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.9)
2025-11-01T05:56:55.179Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:56:55.191Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T05:57:07.175Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:57:13.218Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T05:57:13.531Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T05:57:13.921Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T05:57:14.015Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T05:57:19.175Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:57:31.175Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:57:31.187Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T05:57:40.816Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x50)
2025-11-01T05:57:40.828Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T05:57:40.867Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T05:57:43.171Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:57:43.187Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.9)
2025-11-01T05:57:55.171Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T05:57:55.183Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T05:58:07.171Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:58:19.171Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:58:31.167Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:58:31.179Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T05:58:43.167Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T05:58:43.179Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-01T05:58:53.859Z:INFO:active_lb.c:308:SMt:(11.0 13.0 15.0)A Free:(5.0 3.0 1.0)A ALB:(15.7 14.1 11.3)A
2025-11-01T05:58:55.167Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-01T05:59:07.164Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:59:19.164Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.9 due to current limit: Active-LoadBalancing
2025-11-01T05:59:31.164Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.7 due to current limit: Active-LoadBalancing
2025-11-01T05:59:31.175Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.8->19.5)
2025-11-01T05:59:43.160Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-01T05:59:43.171Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-01T05:59:55.160Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T05:59:55.171Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-01T06:00:07.160Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-01T06:00:19.156Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-01T06:00:31.156Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T06:00:31.167Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-01T06:00:43.156Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:00:43.167Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.9)
2025-11-01T06:00:53.000Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-01T06:00:53.011Z:INFO:db_chargingprofi:26: socket 0
2025-11-01T06:00:53.019Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-01T06:00:53.027Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-01T06:00:53.035Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-01T06:00:53.042Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-01T06:00:53.054Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-01T06:00:53.062Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-01T06:00:53.070Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-01T06:00:53.078Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-01T06:00:53.089Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-01T06:00:53.097Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-01T06:00:53.105Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-01T06:00:53.113Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-01T06:00:53.121Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-01T06:00:53.128Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-01T06:00:53.136Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-01T06:00:53.144Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-01T06:00:53.156Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-01T06:00:53.164Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-01T06:00:53.171Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-01T06:00:53.179Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-01T06:00:53.187Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-01T06:00:55.152Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T06:00:55.167Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T06:01:07.152Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:01:19.152Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T06:01:31.148Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:01:31.164Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T06:01:38.113Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T06:01:38.199Z:SECURITY:taskWebClient.c:446:Received unauthorized request, so removing client
2025-11-01T06:01:38.210Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T06:01:38.238Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T06:01:40.164Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T06:01:40.484Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T06:01:41.191Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T06:01:43.148Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T06:01:43.160Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.9)
2025-11-01T06:01:55.148Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-01T06:01:55.160Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T06:02:07.144Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:02:19.144Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T06:02:31.144Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:02:31.156Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.2)
2025-11-01T06:02:36.132Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x50)
2025-11-01T06:02:36.140Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T06:02:36.238Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T06:02:43.140Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:02:43.156Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-01T06:02:45.957Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T06:02:46.093Z:SECURITY:taskWebClient.c:446:Received unauthorized request, so removing client
2025-11-01T06:02:46.105Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T06:02:46.195Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T06:02:47.917Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T06:02:48.246Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T06:02:48.859Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T06:02:55.140Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T06:02:55.152Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T06:02:55.203Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x50)
2025-11-01T06:02:55.214Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T06:02:55.304Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T06:03:07.140Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:03:07.785Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=233.4V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T06:03:07.796Z:USER:taskMaster.c:6720:Socket #1: I1=10.8A I2=10.8A I3=10.8A P=7.5kW Idc=0.7mA
2025-11-01T06:03:19.136Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T06:03:31.136Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:03:31.148Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.2)
2025-11-01T06:03:43.136Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:03:43.148Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-01T06:03:55.132Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T06:03:55.148Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T06:04:07.132Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:04:19.132Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-01T06:04:31.128Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:04:31.144Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-01T06:04:43.128Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T06:04:43.140Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-01T06:04:45.730Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-11-01T06:04:55.128Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:05:07.125Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T06:05:19.125Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:05:19.136Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T06:05:31.125Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T06:05:31.136Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-01T06:05:43.121Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:05:55.121Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T06:06:07.121Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.9 due to current limit: Active-LoadBalancing
2025-11-01T06:06:19.117Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.7 due to current limit: Active-LoadBalancing
2025-11-01T06:06:19.132Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.7->19.5)
2025-11-01T06:06:31.117Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-01T06:06:31.128Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-01T06:06:43.117Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:06:43.128Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-01T06:06:55.117Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T06:06:55.128Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.7)
2025-11-01T06:07:07.113Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:07:19.113Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T06:07:31.113Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.9 due to current limit: Active-LoadBalancing
2025-11-01T06:07:36.597Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T06:07:36.925Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T06:07:37.273Z:WARNING:web_functionalit:48:Failed to parse property '2068_1'
2025-11-01T06:07:37.285Z:WARNING:web_functionalit:48:Failed to parse property '2068_2'
2025-11-01T06:07:37.296Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T06:07:37.789Z:WARNING:web_functionalit:48:Failed to parse property '8006_0'
2025-11-01T06:07:37.914Z:WARNING:web_functionalit:48:Failed to parse property '8201_0'
2025-11-01T06:07:37.921Z:WARNING:web_functionalit:48:Failed to parse property '8202_0'
2025-11-01T06:07:37.929Z:WARNING:web_functionalit:48:Failed to parse property '8203_0'
2025-11-01T06:07:37.941Z:WARNING:web_functionalit:48:Failed to parse property '8301_0'
2025-11-01T06:07:37.949Z:WARNING:web_functionalit:48:Failed to parse property '8302_0'
2025-11-01T06:07:38.070Z:WARNING:web_functionalit:48:Failed to parse property '8303_0'
2025-11-01T06:07:38.082Z:WARNING:web_functionalit:48:Failed to parse property '8101_1'
2025-11-01T06:07:38.089Z:WARNING:web_functionalit:48:Failed to parse property '8101_2'
2025-11-01T06:07:38.101Z:WARNING:web_functionalit:48:Failed to parse property '8102_1'
2025-11-01T06:07:38.109Z:WARNING:web_functionalit:48:Failed to parse property '8102_2'
2025-11-01T06:07:38.117Z:WARNING:web_functionalit:48:Failed to parse property '8103_1'
2025-11-01T06:07:38.128Z:WARNING:web_functionalit:48:Failed to parse property '8103_2'
2025-11-01T06:07:38.136Z:WARNING:web_functionalit:48:Failed to parse property '8108_1'
2025-11-01T06:07:38.148Z:WARNING:web_functionalit:48:Failed to parse property '8108_2'
2025-11-01T06:07:38.156Z:WARNING:web_functionalit:48:Failed to parse property '8107_1'
2025-11-01T06:07:38.164Z:WARNING:web_functionalit:48:Failed to parse property '8107_2'
2025-11-01T06:07:38.175Z:WARNING:web_functionalit:48:Failed to parse property '810A_1'
2025-11-01T06:07:38.183Z:WARNING:web_functionalit:48:Failed to parse property '810A_2'
2025-11-01T06:07:38.191Z:WARNING:web_functionalit:48:Failed to parse property '8109_1'
2025-11-01T06:07:38.203Z:WARNING:web_functionalit:48:Failed to parse property '8109_2'
2025-11-01T06:07:38.367Z:WARNING:web_functionalit:48:Failed to parse property '2188_0'
2025-11-01T06:07:43.109Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.7 due to current limit: Active-LoadBalancing
2025-11-01T06:07:43.121Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.7->19.4)
2025-11-01T06:07:55.109Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:07:55.121Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T06:08:04.277Z:SECURITY:httpd_login.c:149:Invalid password for user: 'admin'
2025-11-01T06:08:04.285Z:WARNING:web_functionali:101:Invalid username/password provided. Login not allowed
2025-11-01T06:08:06.199Z:SECURITY:taskWebClient.c:446:Received unauthorized request, so removing client
2025-11-01T06:08:06.207Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T06:08:06.253Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T06:08:07.109Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T06:08:07.121Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-01T06:08:11.121Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T06:08:11.535Z:SECURITY:httpd_login.c:149:Invalid password for user: 'admin'
2025-11-01T06:08:11.542Z:WARNING:web_functionali:101:Invalid username/password provided. Login not allowed
2025-11-01T06:08:16.187Z:SECURITY:taskWebClient.c:446:Received unauthorized request, so removing client
2025-11-01T06:08:16.199Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T06:08:16.265Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T06:08:19.105Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:08:27.984Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T06:08:28.085Z:SECURITY:taskWebClient.c:446:Received unauthorized request, so removing client
2025-11-01T06:08:28.097Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T06:08:28.121Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T06:08:29.937Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T06:08:30.277Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T06:08:30.527Z:WARNING:web_functionalit:48:Failed to parse property '2068_1'
2025-11-01T06:08:30.535Z:WARNING:web_functionalit:48:Failed to parse property '2068_2'
2025-11-01T06:08:30.546Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T06:08:31.015Z:WARNING:web_functionalit:48:Failed to parse property '8006_0'
2025-11-01T06:08:31.105Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T06:08:31.167Z:WARNING:web_functionalit:48:Failed to parse property '8201_0'
2025-11-01T06:08:31.179Z:WARNING:web_functionalit:48:Failed to parse property '8202_0'
2025-11-01T06:08:31.187Z:WARNING:web_functionalit:48:Failed to parse property '8203_0'
2025-11-01T06:08:31.195Z:WARNING:web_functionalit:48:Failed to parse property '8301_0'
2025-11-01T06:08:31.207Z:WARNING:web_functionalit:48:Failed to parse property '8302_0'
2025-11-01T06:08:31.316Z:WARNING:web_functionalit:48:Failed to parse property '8303_0'
2025-11-01T06:08:31.328Z:WARNING:web_functionalit:48:Failed to parse property '8101_1'
2025-11-01T06:08:31.335Z:WARNING:web_functionalit:48:Failed to parse property '8101_2'
2025-11-01T06:08:31.343Z:WARNING:web_functionalit:48:Failed to parse property '8102_1'
2025-11-01T06:08:31.355Z:WARNING:web_functionalit:48:Failed to parse property '8102_2'
2025-11-01T06:08:31.363Z:WARNING:web_functionalit:48:Failed to parse property '8103_1'
2025-11-01T06:08:31.375Z:WARNING:web_functionalit:48:Failed to parse property '8103_2'
2025-11-01T06:08:31.382Z:WARNING:web_functionalit:48:Failed to parse property '8108_1'
2025-11-01T06:08:31.390Z:WARNING:web_functionalit:48:Failed to parse property '8108_2'
2025-11-01T06:08:31.402Z:WARNING:web_functionalit:48:Failed to parse property '8107_1'
2025-11-01T06:08:31.410Z:WARNING:web_functionalit:48:Failed to parse property '8107_2'
2025-11-01T06:08:31.421Z:WARNING:web_functionalit:48:Failed to parse property '810A_1'
2025-11-01T06:08:31.429Z:WARNING:web_functionalit:48:Failed to parse property '810A_2'
2025-11-01T06:08:31.437Z:WARNING:web_functionalit:48:Failed to parse property '8109_1'
2025-11-01T06:08:31.449Z:WARNING:web_functionalit:48:Failed to parse property '8109_2'
2025-11-01T06:08:31.613Z:WARNING:web_functionalit:48:Failed to parse property '2188_0'
2025-11-01T06:08:33.488Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x0)
2025-11-01T06:08:33.500Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T06:08:33.605Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T06:08:43.105Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->12.0 due to current limit: Active-LoadBalancing
2025-11-01T06:08:45.523Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T06:08:45.937Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T06:08:46.304Z:WARNING:web_functionalit:48:Failed to parse property '2068_1'
2025-11-01T06:08:46.312Z:WARNING:web_functionalit:48:Failed to parse property '2068_2'
2025-11-01T06:08:46.328Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T06:08:46.781Z:WARNING:web_functionalit:48:Failed to parse property '8006_0'
2025-11-01T06:08:46.941Z:WARNING:web_functionalit:48:Failed to parse property '8201_0'
2025-11-01T06:08:46.953Z:WARNING:web_functionalit:48:Failed to parse property '8202_0'
2025-11-01T06:08:46.960Z:WARNING:web_functionalit:48:Failed to parse property '8203_0'
2025-11-01T06:08:46.972Z:WARNING:web_functionalit:48:Failed to parse property '8301_0'
2025-11-01T06:08:46.980Z:WARNING:web_functionalit:48:Failed to parse property '8302_0'
2025-11-01T06:08:47.093Z:WARNING:web_functionalit:48:Failed to parse property '8303_0'
2025-11-01T06:08:47.101Z:WARNING:web_functionalit:48:Failed to parse property '8101_1'
2025-11-01T06:08:47.113Z:WARNING:web_functionalit:48:Failed to parse property '8101_2'
2025-11-01T06:08:47.121Z:WARNING:web_functionalit:48:Failed to parse property '8102_1'
2025-11-01T06:08:47.128Z:WARNING:web_functionalit:48:Failed to parse property '8102_2'
2025-11-01T06:08:47.140Z:WARNING:web_functionalit:48:Failed to parse property '8103_1'
2025-11-01T06:08:47.148Z:WARNING:web_functionalit:48:Failed to parse property '8103_2'
2025-11-01T06:08:47.156Z:WARNING:web_functionalit:48:Failed to parse property '8108_1'
2025-11-01T06:08:47.167Z:WARNING:web_functionalit:48:Failed to parse property '8108_2'
2025-11-01T06:08:47.175Z:WARNING:web_functionalit:48:Failed to parse property '8107_1'
2025-11-01T06:08:47.187Z:WARNING:web_functionalit:48:Failed to parse property '8107_2'
2025-11-01T06:08:47.195Z:WARNING:web_functionalit:48:Failed to parse property '810A_1'
2025-11-01T06:08:47.203Z:WARNING:web_functionalit:48:Failed to parse property '810A_2'
2025-11-01T06:08:47.214Z:WARNING:web_functionalit:48:Failed to parse property '8109_1'
2025-11-01T06:08:47.222Z:WARNING:web_functionalit:48:Failed to parse property '8109_2'
2025-11-01T06:08:47.367Z:WARNING:web_functionalit:48:Failed to parse property '2188_0'
2025-11-01T06:08:53.796Z:INFO:active_lb.c:308:SMt:(12.0 15.0 16.0)A Free:(4.0 1.0 0.0)A ALB:(16.0 12.2 12.0)A
2025-11-01T06:08:55.101Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->11.8 due to current limit: Active-LoadBalancing
2025-11-01T06:08:55.117Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.9->19.6)
2025-11-01T06:09:03.394Z:USER:taskMaster.c:6582:Temperature: 30.6 C
2025-11-01T06:09:07.101Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T06:09:07.113Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-01T06:09:09.621Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T06:09:09.910Z:WARNING:web_functionalit:48:Failed to parse property '2068_1'
2025-11-01T06:09:09.917Z:WARNING:web_functionalit:48:Failed to parse property '2068_2'
2025-11-01T06:09:09.933Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T06:09:10.398Z:WARNING:web_functionalit:48:Failed to parse property '8006_0'
2025-11-01T06:09:10.519Z:WARNING:web_functionalit:48:Failed to parse property '8201_0'
2025-11-01T06:09:10.531Z:WARNING:web_functionalit:48:Failed to parse property '8202_0'
2025-11-01T06:09:10.539Z:WARNING:web_functionalit:48:Failed to parse property '8203_0'
2025-11-01T06:09:10.546Z:WARNING:web_functionalit:48:Failed to parse property '8301_0'
2025-11-01T06:09:10.558Z:WARNING:web_functionalit:48:Failed to parse property '8302_0'
2025-11-01T06:09:10.710Z:WARNING:web_functionalit:48:Failed to parse property '8303_0'
2025-11-01T06:09:10.718Z:WARNING:web_functionalit:48:Failed to parse property '8101_1'
2025-11-01T06:09:10.726Z:WARNING:web_functionalit:48:Failed to parse property '8101_2'
2025-11-01T06:09:10.738Z:WARNING:web_functionalit:48:Failed to parse property '8102_1'
2025-11-01T06:09:10.746Z:WARNING:web_functionalit:48:Failed to parse property '8102_2'
2025-11-01T06:09:10.757Z:WARNING:web_functionalit:48:Failed to parse property '8103_1'
2025-11-01T06:09:10.765Z:WARNING:web_functionalit:48:Failed to parse property '8103_2'
2025-11-01T06:09:10.773Z:WARNING:web_functionalit:48:Failed to parse property '8108_1'
2025-11-01T06:09:10.785Z:WARNING:web_functionalit:48:Failed to parse property '8108_2'
2025-11-01T06:09:10.792Z:WARNING:web_functionalit:48:Failed to parse property '8107_1'
2025-11-01T06:09:10.800Z:WARNING:web_functionalit:48:Failed to parse property '8107_2'
2025-11-01T06:09:10.812Z:WARNING:web_functionalit:48:Failed to parse property '810A_1'
2025-11-01T06:09:10.820Z:WARNING:web_functionalit:48:Failed to parse property '810A_2'
2025-11-01T06:09:10.828Z:WARNING:web_functionalit:48:Failed to parse property '8109_1'
2025-11-01T06:09:10.839Z:WARNING:web_functionalit:48:Failed to parse property '8109_2'
2025-11-01T06:09:11.062Z:WARNING:web_functionalit:48:Failed to parse property '2188_0'
2025-11-01T06:09:19.101Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:09:19.113Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-01T06:09:31.097Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-01T06:09:31.113Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-01T06:09:43.097Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.7)
2025-11-01T06:09:55.097Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:10:07.093Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T06:10:19.093Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-01T06:10:19.105Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.3)
2025-11-01T06:10:31.093Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:10:31.105Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-01T06:10:38.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T06:10:43.089Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T06:10:43.105Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.8)
2025-11-01T06:10:55.089Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-01T06:10:55.101Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-01T06:11:07.089Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:11:19.085Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T06:11:31.085Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.9 due to current limit: Active-LoadBalancing
2025-11-01T06:11:43.085Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.7 due to current limit: Active-LoadBalancing
2025-11-01T06:11:43.097Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.8->19.5)
2025-11-01T06:11:55.082Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-01T06:11:55.097Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.3)
2025-11-01T06:12:02.414Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T06:12:02.421Z:WARNING:web_functionalit:48:Failed to parse property '2082_0'
2025-11-01T06:12:07.082Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:12:07.093Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-01T06:12:13.714Z:WARNING:web_functionalit:48:Failed to parse property '208B_1'
2025-11-01T06:12:13.726Z:WARNING:web_functionalit:48:Failed to parse property '208B_2'
2025-11-01T06:12:19.082Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-01T06:12:19.093Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-01T06:12:31.078Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:12:43.078Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T06:12:55.078Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->12.0 due to current limit: Active-LoadBalancing
2025-11-01T06:12:58.886Z:WARNING:web_functionalit:48:Failed to parse property '208B_1'
2025-11-01T06:12:58.894Z:WARNING:web_functionalit:48:Failed to parse property '208B_2'
2025-11-01T06:13:03.078Z:WARNING:web_functionalit:48:Failed to parse property '2078_1'
2025-11-01T06:13:03.085Z:WARNING:web_functionalit:48:Failed to parse property '2078_2'
2025-11-01T06:13:03.093Z:WARNING:web_functionalit:48:Failed to parse property '2100_0'
2025-11-01T06:13:03.105Z:WARNING:web_functionalit:48:Failed to parse property '2101_0'
2025-11-01T06:13:03.113Z:WARNING:web_functionalit:48:Failed to parse property '2102_0'
2025-11-01T06:13:06.261Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T06:13:06.273Z:WARNING:web_functionalit:48:Failed to parse property '2082_0'
2025-11-01T06:13:07.074Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->11.8 due to current limit: Active-LoadBalancing
2025-11-01T06:13:07.089Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.9->19.6)
2025-11-01T06:13:12.472Z:WARNING:web_functionalit:48:Failed to parse property '2600_0'
2025-11-01T06:13:19.074Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T06:13:19.085Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.4)
2025-11-01T06:13:31.074Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:13:31.085Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T06:13:43.070Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T06:13:43.085Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-01T06:13:55.070Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:14:07.070Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T06:14:10.828Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x0)
2025-11-01T06:14:10.835Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T06:14:10.894Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T06:14:18.484Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T06:14:18.816Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T06:14:19.066Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->12.0 due to current limit: Active-LoadBalancing
2025-11-01T06:14:19.101Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T06:14:19.191Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T06:14:31.066Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->11.8 due to current limit: Active-LoadBalancing
2025-11-01T06:14:31.078Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.9->19.6)
2025-11-01T06:14:40.148Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x50)
2025-11-01T06:14:40.160Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T06:14:40.203Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T06:14:43.066Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T06:14:43.078Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.4)
2025-11-01T06:14:45.765Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-11-01T06:14:55.066Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:14:55.078Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T06:15:07.062Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T06:15:07.074Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-01T06:15:19.062Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-01T06:15:19.074Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-01T06:15:31.062Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:15:43.109Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-01T06:15:55.109Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-01T06:16:07.105Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T06:16:07.121Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-01T06:16:19.105Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:16:19.117Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.9)
2025-11-01T06:16:31.105Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T06:16:31.117Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T06:16:43.101Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:16:55.101Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T06:17:07.101Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:17:07.113Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T06:17:19.097Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T06:17:19.113Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-01T06:17:31.097Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-01T06:17:31.109Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-01T06:17:43.097Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:17:55.093Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-01T06:18:07.093Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-01T06:18:07.687Z:USER:taskMaster.c:6684:Socket #1: L1N=231.2V L2N=232.2V L3N=231.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T06:18:07.699Z:USER:taskMaster.c:6720:Socket #1: I1=11.2A I2=11.2A I3=11.1A P=7.7kW Idc=0.7mA
2025-11-01T06:18:19.093Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T06:18:19.105Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-01T06:18:31.089Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:18:31.105Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-01T06:18:43.089Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T06:18:43.101Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.8)
2025-11-01T06:18:53.734Z:INFO:active_lb.c:308:SMt:(11.0 12.0 15.0)A Free:(5.0 4.0 1.0)A ALB:(15.7 14.9 11.3)A
2025-11-01T06:18:55.089Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:19:07.085Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T06:19:19.085Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-01T06:19:19.097Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.3)
2025-11-01T06:19:31.085Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:19:31.097Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.9)
2025-11-01T06:19:43.082Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T06:19:43.097Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T06:19:55.082Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:20:07.082Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-01T06:20:19.082Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-01T06:20:31.078Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T06:20:31.089Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-01T06:20:43.078Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:20:43.089Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.9)
2025-11-01T06:20:55.078Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T06:20:55.089Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T06:21:07.074Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:21:19.074Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T06:21:31.074Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:21:31.085Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T06:21:43.070Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T06:21:43.082Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-01T06:21:55.070Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-01T06:21:55.082Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-01T06:22:07.070Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:22:19.066Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-01T06:22:31.066Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-01T06:22:43.066Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-01T06:22:43.078Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-01T06:22:55.062Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:22:55.078Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.9)
2025-11-01T06:23:07.062Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T06:23:07.074Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T06:23:19.062Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-01T06:23:19.074Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-01T06:23:31.058Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-01T06:23:43.058Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:23:55.058Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-01T06:24:03.750Z:USER:taskMaster.c:6582:Temperature: 30.8 C
2025-11-01T06:24:07.054Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:24:07.070Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-01T06:24:19.054Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:24:19.066Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-01T06:24:31.054Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-01T06:24:31.066Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T06:24:43.050Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:24:45.800Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-11-01T06:24:55.050Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T06:25:07.050Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:25:07.062Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T06:25:19.046Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T06:25:19.062Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.9)
2025-11-01T06:25:31.046Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-01T06:25:31.058Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T06:25:38.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T06:25:43.046Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:25:55.042Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-01T06:26:07.042Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-01T06:26:07.054Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-01T06:26:19.042Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-01T06:26:19.054Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.9)
2025-11-01T06:26:31.039Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-01T06:26:31.054Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-01T06:26:43.039Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-01T06:26:53.132Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T06:26:53.144Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T06:26:53.152Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T06:26:53.160Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T06:26:53.277Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T06:26:53.796Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->15.0 due to current limit: Active-LoadBalancing
2025-11-01T06:26:54.136Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.9% (14.9 A)
2025-11-01T06:26:54.148Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.2/-11.4, tag: 04BB29EAFD0F94
2025-11-01T06:26:58.796Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->7.2 due to current limit: Active-LoadBalancing
2025-11-01T06:26:59.187Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.0% (7.2 A)
2025-11-01T06:27:07.035Z:INFO:taskMain.c:5996:Socket #1: Active current 7.2->4.3 due to current limit: Active-LoadBalancing
2025-11-01T06:27:07.050Z:WARNING:taskMain.c:4698:Socket #1: maximum current(4.35) < minimum current(6.00)
2025-11-01T06:27:07.082Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T06:27:07.093Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T06:27:07.101Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T06:27:07.265Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-01T06:27:08.078Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.2/9.2, tag: 04BB
2025-11-01T06:27:08.078Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T06:27:19.035Z:INFO:taskMain.c:5996:Socket #1: Active current 4.3->7.0 due to current limit: Active-LoadBalancing
2025-11-01T06:27:19.078Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T06:27:19.089Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T06:27:19.097Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T06:27:19.187Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T06:27:20.085Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T06:27:31.035Z:INFO:taskMain.c:5996:Socket #1: Active current 7.0->8.6 due to current limit: Active-LoadBalancing
2025-11-01T06:27:31.195Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.3% (8.6 A)
2025-11-01T06:27:43.031Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->9.6 due to current limit: Active-LoadBalancing
2025-11-01T06:27:43.312Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.9% (9.5 A)
2025-11-01T06:27:49.125Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-01T06:27:49.136Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-01T06:27:49.371Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-01T06:27:49.378Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-01T06:27:50.121Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-01T06:27:53.125Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T06:27:53.152Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T06:27:53.160Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-01T06:27:53.625Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T06:27:53.636Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T06:27:54.160Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T06:27:54.652Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.2/-11.4, tag: 04BB29EAFD0F94
2025-11-01T06:27:55.031Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->10.1 due to current limit: Active-LoadBalancing
2025-11-01T06:27:55.660Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.8% (10.1 A)
2025-11-01T06:28:07.031Z:INFO:taskMain.c:5996:Socket #1: Active current 10.1->10.5 due to current limit: Active-LoadBalancing
2025-11-01T06:28:07.781Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.4% (10.4 A)
2025-11-01T06:28:19.027Z:INFO:taskMain.c:5996:Socket #1: Active current 10.5->10.7 due to current limit: Active-LoadBalancing
2025-11-01T06:28:31.027Z:INFO:taskMain.c:5996:Socket #1: Active current 10.7->10.8 due to current limit: Active-LoadBalancing
2025-11-01T06:28:53.667Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(14.9 14.9 10.9)A
2025-11-01T06:28:55.027Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->10.9 due to current limit: Active-LoadBalancing
2025-11-01T06:33:07.593Z:USER:taskMaster.c:6684:Socket #1: L1N=236.0V L2N=236.1V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T06:33:07.605Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T06:38:45.457Z:INFO:heap_trace.c:493:free: 48392/160768 (30.1%) min: 42896 (26.7%) alloc #: 295
2025-11-01T06:38:45.468Z:INFO:heap_trace.c:495:fragm: 7.1% 4K: 15.4% free blocks: # 10 largest: 44944
2025-11-01T06:38:46.714Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T06:38:47.074Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T06:38:47.417Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T06:38:47.527Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T06:38:47.949Z:SECURITY:web_functionalit:68:Changed '2059_00' from 1761979131674 => 1761979130211
2025-11-01T06:38:55.644Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-01T06:39:06.195Z:USER:taskMaster.c:6582:Temperature: 29.6 C
2025-11-01T06:39:42.320Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x0)
2025-11-01T06:39:42.332Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T06:39:42.378Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T06:40:38.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T06:45:08.960Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->9.4 due to current limit: Active-LoadBalancing
2025-11-01T06:45:09.812Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.6% (9.4 A)
2025-11-01T06:45:20.960Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->7.2 due to current limit: Active-LoadBalancing
2025-11-01T06:45:21.929Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.0% (7.2 A)
2025-11-01T06:45:32.957Z:INFO:taskMain.c:5996:Socket #1: Active current 7.2->5.9 due to current limit: Active-LoadBalancing
2025-11-01T06:45:32.972Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.94) < minimum current(6.00)
2025-11-01T06:45:33.003Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-01T06:45:33.011Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T06:45:33.023Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-01T06:45:33.039Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-01T06:45:34.000Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.2, tag: 04BB
2025-11-01T06:45:34.000Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-01T06:45:44.957Z:INFO:taskMain.c:5996:Socket #1: Active current 5.9->5.2 due to current limit: Active-LoadBalancing
2025-11-01T06:45:56.957Z:INFO:taskMain.c:5996:Socket #1: Active current 5.2->4.7 due to current limit: Active-LoadBalancing
2025-11-01T06:46:08.953Z:INFO:taskMain.c:5996:Socket #1: Active current 4.7->4.4 due to current limit: Active-LoadBalancing
2025-11-01T06:46:20.953Z:INFO:taskMain.c:5996:Socket #1: Active current 4.4->4.3 due to current limit: Active-LoadBalancing
2025-11-01T06:46:32.953Z:INFO:taskMain.c:5996:Socket #1: Active current 4.3->4.2 due to current limit: Active-LoadBalancing
2025-11-01T06:47:08.949Z:INFO:taskMain.c:5996:Socket #1: Active current 4.1->4.0 due to current limit: Active-LoadBalancing
2025-11-01T06:48:09.535Z:USER:taskMaster.c:6684:Socket #1: L1N=234.9V L2N=234.2V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T06:48:09.546Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T06:48:55.582Z:INFO:active_lb.c:308:SMt:(1.0 12.0 5.0)A Free:(15.0 4.0 11.0)A ALB:(14.6 4.0 11.0)A
2025-11-01T06:50:32.925Z:INFO:taskMain.c:5996:Socket #1: Active current 4.0->7.6 due to current limit: Active-LoadBalancing
2025-11-01T06:50:32.937Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.6% (7.6 A)
2025-11-01T06:50:32.968Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T06:50:32.980Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T06:50:33.019Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T06:50:33.937Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T06:50:33.988Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T06:50:44.925Z:INFO:taskMain.c:5996:Socket #1: Active current 7.6->9.8 due to current limit: Active-LoadBalancing
2025-11-01T06:50:45.093Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.2% (9.7 A)
2025-11-01T06:50:56.925Z:INFO:taskMain.c:5996:Socket #1: Active current 9.8->11.0 due to current limit: Active-LoadBalancing
2025-11-01T06:50:57.214Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.3% (11.0 A)
2025-11-01T06:51:03.015Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-01T06:51:03.027Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-01T06:51:03.273Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-01T06:51:03.281Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-01T06:51:04.023Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-01T06:51:07.015Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T06:51:07.054Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T06:51:07.062Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-01T06:51:07.515Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T06:51:07.531Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T06:51:08.062Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T06:51:08.554Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T06:54:06.597Z:USER:taskMaster.c:6582:Temperature: 28.1 C
2025-11-01T06:55:38.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T06:58:55.519Z:INFO:active_lb.c:308:SMt:(1.0 3.0 5.0)A Free:(15.0 13.0 11.0)A ALB:(15.0 12.8 11.0)A
2025-11-01T06:59:08.871Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->12.2 due to current limit: Active-LoadBalancing
2025-11-01T06:59:09.261Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.3% (12.2 A)
2025-11-01T06:59:20.871Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.9 due to current limit: Active-LoadBalancing
2025-11-01T06:59:21.382Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.5% (12.9 A)
2025-11-01T07:00:44.863Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-11-01T07:00:45.203Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-01T07:00:56.859Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-11-01T07:01:02.609Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-01T07:01:02.617Z:INFO:db_chargingprofi:26: socket 0
2025-11-01T07:01:02.625Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-01T07:01:02.636Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-01T07:01:02.640Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-01T07:01:02.652Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-01T07:01:02.664Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-01T07:01:02.671Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-01T07:01:02.679Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-01T07:01:02.687Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-01T07:01:02.695Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-01T07:01:02.703Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-01T07:01:02.710Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-01T07:01:02.718Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-01T07:01:02.726Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-01T07:01:02.738Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-01T07:01:02.746Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-01T07:01:02.753Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-01T07:01:02.765Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-01T07:01:02.773Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-01T07:01:02.781Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-01T07:01:02.789Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-01T07:01:02.796Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-01T07:01:20.859Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->10.9 due to current limit: Active-LoadBalancing
2025-11-01T07:01:21.558Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.1% (10.9 A)
2025-11-01T07:01:32.855Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->9.7 due to current limit: Active-LoadBalancing
2025-11-01T07:01:33.675Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.2% (9.7 A)
2025-11-01T07:01:44.855Z:INFO:taskMain.c:5996:Socket #1: Active current 9.7->9.0 due to current limit: Active-LoadBalancing
2025-11-01T07:01:45.796Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.0% (9.0 A)
2025-11-01T07:01:56.855Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.6 due to current limit: Active-LoadBalancing
2025-11-01T07:01:56.906Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.3% (8.6 A)
2025-11-01T07:02:08.851Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.4 due to current limit: Active-LoadBalancing
2025-11-01T07:02:20.851Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.2 due to current limit: Active-LoadBalancing
2025-11-01T07:02:44.847Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->8.1 due to current limit: Active-LoadBalancing
2025-11-01T07:03:09.441Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=233.4V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T07:03:09.453Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T07:04:56.835Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->10.0 due to current limit: Active-LoadBalancing
2025-11-01T07:04:57.675Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.6% (10.0 A)
2025-11-01T07:05:08.835Z:INFO:taskMain.c:5996:Socket #1: Active current 10.0->11.2 due to current limit: Active-LoadBalancing
2025-11-01T07:05:09.792Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.6% (11.2 A)
2025-11-01T07:05:20.832Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.9 due to current limit: Active-LoadBalancing
2025-11-01T07:05:20.902Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.8% (11.9 A)
2025-11-01T07:05:32.832Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->12.4 due to current limit: Active-LoadBalancing
2025-11-01T07:05:33.023Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.5% (12.3 A)
2025-11-01T07:05:44.832Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-11-01T07:05:56.828Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-11-01T07:06:08.828Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-11-01T07:06:20.828Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-01T07:06:32.824Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-01T07:06:56.824Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-11-01T07:07:08.820Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.4 due to current limit: Active-LoadBalancing
2025-11-01T07:07:08.953Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-11-01T07:07:20.820Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.3 due to current limit: Active-LoadBalancing
2025-11-01T07:07:32.820Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-01T07:07:56.816Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-11-01T07:08:55.453Z:INFO:active_lb.c:308:SMt:(1.0 4.0 2.0)A Free:(15.0 12.0 14.0)A ALB:(15.0 12.0 14.0)A
2025-11-01T07:09:07.003Z:USER:taskMaster.c:6582:Temperature: 27.5 C
2025-11-01T07:09:44.804Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-11-01T07:09:45.484Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-11-01T07:09:56.804Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-11-01T07:10:20.800Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.5 due to current limit: Active-LoadBalancing
2025-11-01T07:10:20.832Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-01T07:10:32.800Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-01T07:10:38.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 900 seconds
2025-11-01T07:10:44.800Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-01T07:11:08.796Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-11-01T07:12:16.835Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T07:12:17.554Z:SECURITY:httpd_login.c:155:WebClient connected (account: admin)
2025-11-01T07:12:17.648Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T07:12:20.789Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-11-01T07:12:21.007Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-11-01T07:12:32.789Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-11-01T07:12:43.152Z:WARNING:web_functionali:139:Could not find prop dwId 2071.01
2025-11-01T07:12:43.160Z:WARNING:web_functionali:139:Could not find prop dwId 2071.02
2025-11-01T07:12:43.167Z:WARNING:web_functionali:139:Could not find prop dwId 2078.01
2025-11-01T07:12:43.179Z:WARNING:web_functionali:139:Could not find prop dwId 2078.02
2025-11-01T07:12:43.187Z:WARNING:web_functionali:139:Could not find prop dwId 2081.00
2025-11-01T07:12:43.195Z:WARNING:web_functionali:139:Could not find prop dwId 2100.00
2025-11-01T07:12:43.207Z:WARNING:web_functionali:139:Could not find prop dwId 2101.00
2025-11-01T07:12:43.214Z:WARNING:web_functionali:139:Could not find prop dwId 2102.00
2025-11-01T07:12:43.222Z:SECURITY:web_functionalit:63:Changed '20f0_06' from 1 => 0
2025-11-01T07:12:43.234Z:SECURITY:web_functionalit:63:Changed '20f1_06' from 5 => 0
2025-11-01T07:12:43.242Z:SECURITY:web_functionalit:63:Changed '20f0_0e' from 1 => 0
2025-11-01T07:12:43.250Z:SECURITY:web_functionalit:63:Changed '20f0_01' from 3 => 1
2025-11-01T07:12:43.257Z:SECURITY:web_functionalit:58:Changed '20F0_03' from 'ws://192.168.178.160:9000/' => ''
2025-11-01T07:12:43.269Z:SECURITY:web_functionalit:63:Changed '20f1_01' from 3 => 1
2025-11-01T07:12:43.277Z:SECURITY:web_functionalit:58:Changed '20F1_03' from 'ws://ws-private.evc-net.com/' => ''
2025-11-01T07:12:43.402Z:SECURITY:web_functionalit:67:Changed '20F1_04' from 15 => 10
2025-11-01T07:12:43.410Z:SECURITY:web_functionalit:58:Changed '20F1_07' from '******' => '******'
2025-11-01T07:12:43.421Z:SECURITY:web_functionalit:63:Changed '20f2_01' from 0 => 1
2025-11-01T07:12:43.429Z:SECURITY:web_functionalit:63:Changed '20f3_01' from 0 => 1
2025-11-01T07:12:43.855Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-01T07:12:44.082Z:INFO:taskCANopen.c:1787:Updated object 0x20f0, 1142 bytes
2025-11-01T07:12:44.257Z:INFO:taskCANopen.c:1787:Updated object 0x20f1, 1142 bytes
2025-11-01T07:12:44.425Z:INFO:taskCANopen.c:1787:Updated object 0x20f2, 1142 bytes
2025-11-01T07:12:44.601Z:INFO:taskCANopen.c:1787:Updated object 0x20f3, 1142 bytes
2025-11-01T07:12:45.921Z:SECURITY:web_functionalit:68:Changed '2187_00' from 1761947112615 => 1761981164673
2025-11-01T07:12:46.875Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-01T07:12:47.128Z:INFO:taskCANopen.c:1787:Updated object 0x2187, 8 bytes
2025-11-01T07:12:56.785Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-11-01T07:13:02.574Z:SECURITY:web_functionali:105:Webserver logout client 1
2025-11-01T07:13:02.593Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T07:13:02.660Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T07:13:04.437Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T07:13:04.546Z:SECURITY:taskWebClient.c:446:Received unauthorized request, so removing client
2025-11-01T07:13:04.558Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T07:13:04.675Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T07:13:06.484Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T07:13:06.562Z:SECURITY:taskWebClient.c:446:Received unauthorized request, so removing client
2025-11-01T07:13:06.574Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T07:13:06.613Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T07:13:08.441Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T07:13:08.890Z:SECURITY:httpd_login.c:155:WebClient RadomskiR connected (account: admin)
2025-11-01T07:13:09.367Z:SECURITY:httpd_login.c:155:WebClient RadomskiR connected (account: admin)
2025-11-01T07:13:09.781Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x50)
2025-11-01T07:13:09.789Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T07:13:09.804Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T07:13:56.777Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-11-01T07:13:56.949Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-11-01T07:14:08.777Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-11-01T07:14:10.738Z:WARNING:taskMain.c:4758:Socket #1: EV disconnected while charging (11.6V)
2025-11-01T07:14:10.765Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->0.0 due to current limit: Cable
2025-11-01T07:14:10.777Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAIT_FOR_EV_RECONNECT
2025-11-01T07:14:10.789Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_A
2025-11-01T07:14:10.820Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_TERMINATING
2025-11-01T07:14:10.832Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_VEHICLE
2025-11-01T07:14:10.871Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-01T07:14:11.085Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-01T07:14:11.093Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-01T07:14:11.101Z:INFO:taskMain.c:6504:Socket #1: PP 34464 Ohm (0 A)
2025-11-01T07:14:11.855Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_TERMINATING, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-01T07:14:14.871Z:INFO:taskMaster.c:4957:Socket #1: state main : WAIT_FOR_STOP_METERVALUE
2025-11-01T07:14:15.398Z:INFO:taskMain.c:938:Socket #1: charging session status set inactive
2025-11-01T07:14:15.406Z:USER:board_ng9xx.c:5068:Socket #1: unlock socket motor
2025-11-01T07:14:15.421Z:INFO:taskMaster.c:4957:Socket #1: state main : WAIT_FOR_DISCONNECT
2025-11-01T07:14:15.488Z:INFO:db_transaction.c:16:Added TransactionStop for socket 1 at 0x00001eaa (ts: 2025-11-01 07:14:15)
2025-11-01T07:14:15.500Z:INFO:db_transaction.c:16:Updated TransactionStart for socket 1 at 0x00001936 (ts: 2025-10-31 16:40:37)
2025-11-01T07:14:15.562Z:INFO:taskMaster.c:4979:Socket #1: state led : AVAILABLE
2025-11-01T07:14:15.574Z:INFO:taskMaster.c:4957:Socket #1: state main : AVAILABLE
2025-11-01T07:14:15.585Z:INFO:taskMain.c:6440:Socket #1: active tag cleared
2025-11-01T07:14:16.546Z:INFO:taskMain.c:1419:Socket #1: main state: AVAILABLE, CP: 0.0/0.0, no tag
2025-11-01T07:15:48.640Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T07:15:48.933Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T07:15:49.332Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T07:15:49.394Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T07:15:49.781Z:SECURITY:web_functionalit:68:Changed '2059_00' from 1761981350228 => 1761981350110
2025-11-01T07:16:18.441Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x50)
2025-11-01T07:16:18.453Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T07:16:18.511Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T07:17:01.957Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T07:17:02.066Z:SECURITY:taskWebClient.c:446:Received unauthorized request, so removing client
2025-11-01T07:17:02.074Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T07:17:02.085Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T07:17:03.914Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T07:17:04.230Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T07:17:04.917Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T07:17:19.582Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x50)
2025-11-01T07:17:19.589Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T07:17:19.664Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T07:17:25.871Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T07:17:26.031Z:SECURITY:taskWebClient.c:446:Received unauthorized request, so removing client
2025-11-01T07:17:26.039Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T07:17:26.109Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T07:17:27.871Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T07:17:28.195Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T07:17:28.867Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T07:17:35.839Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x50)
2025-11-01T07:17:35.847Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T07:17:35.921Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T07:18:09.554Z:USER:taskMaster.c:6684:Socket #1: L1N=235.8V L2N=236.2V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T07:18:55.597Z:INFO:active_lb.c:308:SMt:(2.0 3.0 2.0)A Free:(14.0 13.0 14.0)A ALB:(14.1 12.2 14.0)A
2025-11-01T07:24:07.515Z:USER:taskMaster.c:6582:Temperature: 27.0 C
2025-11-01T07:26:48.589Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T07:26:48.914Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T07:26:49.179Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T07:26:49.246Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T07:26:52.996Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x50)
2025-11-01T07:26:53.007Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T07:26:53.062Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T07:28:55.535Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 12.5 14.9)A
2025-11-01T07:33:09.457Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.0V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T07:38:55.472Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(14.0 13.0 15.0)A ALB:(14.0 12.9 14.4)A
2025-11-01T07:39:07.921Z:USER:taskMaster.c:6582:Temperature: 26.4 C
2025-11-01T07:48:09.363Z:USER:taskMaster.c:6684:Socket #1: L1N=232.0V L2N=231.9V L3N=231.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T07:48:55.410Z:INFO:active_lb.c:308:SMt:(2.0 3.0 2.0)A Free:(14.0 13.0 14.0)A ALB:(14.0 13.0 14.2)A
2025-11-01T07:54:08.328Z:USER:taskMaster.c:6582:Temperature: 26.1 C
2025-11-01T07:58:55.343Z:INFO:active_lb.c:308:SMt:(2.0 4.0 1.0)A Free:(14.0 12.0 15.0)A ALB:(14.0 12.0 15.0)A
2025-11-01T08:03:09.269Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=235.3V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T08:08:55.281Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.0 14.4 15.0)A
2025-11-01T08:09:08.679Z:USER:taskMaster.c:6582:Temperature: 26.0 C
2025-11-01T08:18:09.171Z:USER:taskMaster.c:6684:Socket #1: L1N=236.4V L2N=237.6V L3N=237.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T08:18:55.218Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.0 14.6 15.0)A
2025-11-01T08:24:09.085Z:USER:taskMaster.c:6582:Temperature: 25.6 C
2025-11-01T08:28:55.156Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.0 14.7 15.0)A
2025-11-01T08:33:09.078Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=233.0V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T08:38:40.210Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-01T08:38:40.480Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-01T08:38:46.941Z:INFO:heap_trace.c:493:free: 69192/160768 (43.0%) min: 42896 (26.7%) alloc #: 206
2025-11-01T08:38:46.953Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 11.2% free blocks: # 11 largest: 49560
2025-11-01T08:38:55.093Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.0 15.0 15.0)A
2025-11-01T08:39:09.492Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-01T08:48:08.984Z:USER:taskMaster.c:6684:Socket #1: L1N=235.9V L2N=236.9V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T08:48:55.027Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.0 14.0 15.0)A
2025-11-01T08:54:09.847Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-01T08:58:54.964Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.0 14.0 15.0)A
2025-11-01T09:03:08.890Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=232.9V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T09:08:54.902Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.0 14.8 15.0)A
2025-11-01T09:09:10.250Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-01T09:18:08.792Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.1V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T09:18:54.839Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.0 15.0 15.0)A
2025-11-01T09:24:10.656Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-01T09:28:54.777Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.0 15.0 15.0)A
2025-11-01T09:33:08.699Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=235.7V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T09:33:28.640Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T09:33:29.324Z:SECURITY:httpd_login.c:155:WebClient connected (account: admin)
2025-11-01T09:33:29.417Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T09:34:46.636Z:WARNING:web_functionali:139:Could not find prop dwId 2081.00
2025-11-01T09:34:46.644Z:SECURITY:web_functionalit:63:Changed '20f0_06' from 0 => 1
2025-11-01T09:34:46.656Z:SECURITY:web_functionalit:63:Changed '20f0_0e' from 0 => 1
2025-11-01T09:34:46.664Z:SECURITY:web_functionalit:63:Changed '20f0_01' from 1 => 3
2025-11-01T09:34:46.671Z:SECURITY:web_functionalit:58:Changed '20F0_03' from '' => 'ws://192.168.178.160:9000/'
2025-11-01T09:34:47.621Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-01T09:34:47.859Z:INFO:taskCANopen.c:1787:Updated object 0x20f0, 1142 bytes
2025-11-01T09:34:48.652Z:INFO:web_functionali:159:Executing command: 'reboot'
2025-11-01T09:34:48.738Z:SECURITY:application.c:792:reset: requested, going down..
2025-11-01T09:35:00.921Z:RESET:application.c:414:==========================================
2025-11-01T09:35:00.933Z:INFO:application.c:421:build: Oct 27 2025 13:58:28
2025-11-01T09:35:00.941Z:INFO:application.c:422:version: 7.3.0-4377
2025-11-01T09:35:00.949Z:INFO:application.c:423:compiler: gcc 9.3.1
2025-11-01T09:35:00.957Z:INFO:application.c:285:fwu state inactive
2025-11-01T09:35:00.964Z:INFO:application.c:292:Bootloader version 2.2.2
2025-11-01T09:35:01.375Z:USER:taskCANopen.c:241:Persistent configuration retrieved, 284 items
2025-11-01T09:35:01.390Z:INFO:application.c:328:FLASH read protection 0xcc level 2 (permanent)
2025-11-01T09:35:01.402Z:USER:application.c:470:Using P1 port
2025-11-01T09:35:01.406Z:INFO:application.c:364:System boot #4, cause Software reset
2025-11-01T09:35:01.417Z:INFO:board_ng9xx.c:1602:Registered timeout getHardware
2025-11-01T09:35:03.125Z:INFO:bspMotors.c:616:Socket #1: Timeout while waiting for Cover motor
2025-11-01T09:35:03.183Z:INFO:board_ng9xx.c:1629:Unregistered timeout getHardware
2025-11-01T09:35:03.191Z:INFO:application.c:510:ST MCU ID......................20036419
2025-11-01T09:35:03.203Z:INFO:application.c:511:Device ID:.....................004000203531510532353530
2025-11-01T09:35:03.214Z:INFO:application.c:512:Object ID:.....................ACE0640314
2025-11-01T09:35:03.222Z:INFO:application.c:513:#Sockets.......................1
2025-11-01T09:35:03.230Z:INFO:application.c:514:MAC address eeprom.............not available
2025-11-01T09:35:03.242Z:INFO:application.c:515:Configuration eeprom...........available
2025-11-01T09:35:03.250Z:INFO:application.c:517:Flash EEPROM...................available: manuf. 0x00c2, id 0x2016 (8 MB)
2025-11-01T09:35:03.261Z:INFO:application.c:520:Temperature sensor.............available (20.0/30.8 °C)
2025-11-01T09:35:03.273Z:INFO:application.c:521:Accelerometer/tilt sensor......not available
2025-11-01T09:35:03.281Z:INFO:application.c:522:Ambient light/proximity sensor.not available
2025-11-01T09:35:03.292Z:INFO:application.c:523:Real time clock................available
2025-11-01T09:35:03.300Z:INFO:application.c:524:Mobile network modem...........Autodetect (enabled)
2025-11-01T09:35:03.312Z:INFO:application.c:525:Ethernet PHY...................available
2025-11-01T09:35:03.519Z:INFO:application.c:534:#1 Control Pilot circuit.......available (0.2/-11.7 Volts)
2025-11-01T09:35:03.531Z:INFO:application.c:535:#1 Proximity Pin circuit.......available (100000 Ohms)
2025-11-01T09:35:03.542Z:INFO:application.c:536:#1 Socket motor................available
2025-11-01T09:35:03.550Z:INFO:application.c:537:#1 Cover motor.................not available
2025-11-01T09:35:03.562Z:INFO:application.c:538:#1 Auxiliary I/O...............not available
2025-11-01T09:35:03.570Z:INFO:application.c:539:#1 Button input................not available
2025-11-01T09:35:03.582Z:INFO:application.c:540:#1 NFC reader..................not available
2025-11-01T09:35:03.589Z:INFO:application.c:541:#1 Emergency relays............available
2025-11-01T09:35:03.597Z:INFO:application.c:560:-12V power supply..............available
2025-11-01T09:35:03.609Z:INFO:application.c:561:Smart meter P1 port interface..available
2025-11-01T09:35:03.617Z:INFO:application.c:562:Smart meter Suspend input......not available
2025-11-01T09:35:03.628Z:INFO:application.c:563:Smart meter external Modbus....available
2025-11-01T09:35:03.636Z:INFO:application.c:564:Energy meter ModBus interface..available
2025-11-01T09:35:03.648Z:INFO:application.c:565:Display user interface.........available
2025-11-01T09:35:03.656Z:INFO:application.c:566:PWM Buzzer.....................not available
2025-11-01T09:35:03.664Z:INFO:application.c:569:Auxiliary Board................supported
2025-11-01T09:35:03.675Z:INFO:application.c:570:Auxiliary Board revision.......D
2025-11-01T09:35:03.683Z:INFO:application.c:572:Powerboard revision/assy.......GUNKNOWN (32.0A)
2025-11-01T09:35:03.691Z:INFO:application.c:573:Controllerboard revision/assy..L7
2025-11-01T09:35:03.703Z:INFO:application.c:574:Powerboard relay type..........LATCHING_REVERSED
2025-11-01T09:35:03.710Z:INFO:application.c:592:Operational time ..............0D 00H
2025-11-01T09:35:03.726Z:INFO:db_common.c:147:Initializing all databases..
2025-11-01T09:35:04.156Z:INFO:db_base.c:1325:Initialized Transaction db (firstItem=0x00000000, lastItem=0x00001eaa)
2025-11-01T09:35:04.171Z:INFO:db_base.c:1325:Initialized LocalList db (firstItem=0x00000000, lastItem=0x00000000)
2025-11-01T09:35:04.187Z:INFO:db_base.c:1325:Initialized WhiteList db (firstItem=0x00000000, lastItem=0x00000041)
2025-11-01T09:35:04.203Z:INFO:db_base.c:1325:Initialized ChargingProfile db (firstItem=0x00000000, lastItem=0x000001b1)
2025-11-01T09:35:04.230Z:INFO:db_chargingprofi:75:Defragmented (#0/0, 18ms)
2025-11-01T09:35:04.242Z:INFO:db_chargingprofi:19:Max 45 charging profiles of 100 periods
2025-11-01T09:35:04.250Z:INFO:db_base.c:1325:Initialized Domain db (firstItem=0x00000000, lastItem=0x00000070)
2025-11-01T09:35:04.265Z:USER:ocpp.c:187:Init OCPP for ocpp1.6
2025-11-01T09:35:04.273Z:INFO:board_ng9xx.c:1602:Registered timeout BootNotification
2025-11-01T09:35:04.308Z:INFO:featureKeys.c:78:Unlocked Features: SCN,RFID-reader,4G (80010101)
2025-11-01T09:35:04.320Z:INFO:taskMain.c:599:Socket #1: Authorisation method COM unit via CAN
2025-11-01T09:35:04.332Z:INFO:taskMain.c:602:Socket #1: SocketType Mennekes
2025-11-01T09:35:04.339Z:INFO:taskMain.c:606:Socket #1: startup delay 5 s
2025-11-01T09:35:04.347Z:INFO:board_ng9xx.c:1602:Registered timeout NUVVE
2025-11-01T09:35:04.359Z:INFO:board_ng9xx.c:1602:Registered timeout NUVVE
2025-11-01T09:35:04.375Z:USER:EVsimulator.c:210:EV simulator initialised
2025-11-01T09:35:04.382Z:USER:taskMaster.c:1050:ocpp1.6 Smart Charging Mode
2025-11-01T09:35:04.597Z:INFO:bspEthernet.c:165:Ethernet PHY LAN8710@0x00
2025-11-01T09:35:04.613Z:USER:bspEthernet.c:238:ETH PHY OK
2025-11-01T09:35:04.621Z:INFO:bspEthernet.c:217:MACAddress: [26:64:44:07:10:35]
2025-11-01T09:35:04.628Z:INFO:taskMeter.c:318:Starting smartmeter with protocol P1
2025-11-01T09:35:04.636Z:INFO:scn.c:686:Loadbalancing: Feature enabled
2025-11-01T09:35:04.644Z:INFO:scn.c:687:SCN: Feature enabled [Off]
2025-11-01T09:35:04.652Z:WARNING:scn_communicatio:75:SCN: Not enough sockets for an SCN!
2025-11-01T09:35:04.667Z:INFO:modem.c:1124:Modem state Idle->InitHw
2025-11-01T09:35:04.679Z:INFO:taskMain.c:1294:contactorstabletime : 50
2025-11-01T09:35:04.687Z:INFO:taskMain.c:1295:HFContactorSwitchTime : 60
2025-11-01T09:35:04.703Z:INFO:taskLeds.c:226:LED UI initialized OK
2025-11-01T09:35:04.710Z:INFO:taskMain.c:6180:Socket #1: DSC initialised
2025-11-01T09:35:04.718Z:INFO:station.c:184:Active station current set to 16.0A max
2025-11-01T09:35:04.734Z:INFO:taskMain.c:6504:Socket #1: PP 34464 Ohm (0 A)
2025-11-01T09:35:04.742Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.0% (6.0 A)
2025-11-01T09:35:04.753Z:INFO:comConnect.c:295:Connectivity state: STARTUP
2025-11-01T09:35:04.800Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-11-01T09:35:05.304Z:INFO:taskModbus.c:4526:Address #1: modbus meter vendor : ALF
2025-11-01T09:35:05.312Z:INFO:taskModbus.c:4527:Address #1: modbus meter model : D3001
2025-11-01T09:35:05.324Z:INFO:taskModbus.c:4528:Address #1: modbus meter revision : V1.03
2025-11-01T09:35:05.332Z:INFO:taskModbus.c:4529:Address #1: modbus meter meterNumber : 22391493
2025-11-01T09:35:05.343Z:USER:taskModbus.c:936:Socket_1 Meter(1): meter type DZG_REALLIN found
2025-11-01T09:35:05.667Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-01T09:35:05.675Z:INFO:taskCANopen.c:1212:Persistent memory not cached
2025-11-01T09:35:05.687Z:INFO:taskNFCreader.c:579:Port #0 switch NFC power on
2025-11-01T09:35:05.750Z:INFO:taskMain.c:1419:Socket #1: main state: BOOTING, CP: 0.0/0.0, no tag
2025-11-01T09:35:05.781Z:INFO:taskCANopen.c:2020:CanOpen EEPROM cache size: 284, got 284 objects <284,0>
2025-11-01T09:35:05.808Z:INFO:taskCANopen.c:1787:Updated object 0x2056, 4 bytes
2025-11-01T09:35:05.839Z:USER:taskModbus.c:1107:Socket_1 Meter(1): first meter update, Multiple phase installation
2025-11-01T09:35:06.324Z:USER:bspEthernet.c:342:Mode: 100Mb/s full duplex
2025-11-01T09:35:06.332Z:INFO:taskTCPIP.c:958:Network Cable is now connected
2025-11-01T09:35:06.894Z:USER:taskMaster.c:1329:Node #1, version 7.3.0-4377
2025-11-01T09:35:07.132Z:INFO:taskTCPIP.c:1617: IP address assigned by DHCP
2025-11-01T09:35:07.140Z:INFO:taskTCPIP.c:1645:Network interface is up
2025-11-01T09:35:07.148Z:INFO:taskTCPIP.c:1654: IP : 192.168.178.184
2025-11-01T09:35:07.156Z:INFO:taskTCPIP.c:1655: Netmask : 255.255.255.0
2025-11-01T09:35:07.164Z:INFO:taskTCPIP.c:1656: Gateway : 192.168.178.1
2025-11-01T09:35:07.171Z:INFO:taskTCPIP.c:1657: DNS1 : 192.168.178.1
2025-11-01T09:35:07.179Z:INFO:taskTCPIP.c:1658: DNS2 : 208.67.220.220
2025-11-01T09:35:07.191Z:INFO:taskTCPIP.c:512:Starting mDNS on interface al
2025-11-01T09:35:07.199Z:INFO:taskTCPIP.c:512:Starting Webserver on interface al
2025-11-01T09:35:07.207Z:INFO:taskTCPIP.c:512:Starting Modbus on interface al
2025-11-01T09:35:07.214Z:INFO:taskTCPIP.c:512:Starting P1 on interface al
2025-11-01T09:35:07.222Z:INFO:taskTCPIP.c:512:Starting SCN on interface al
2025-11-01T09:35:07.230Z:INFO:taskTCPIP.c:413:default network set to 'al'
2025-11-01T09:35:07.242Z:INFO:taskWebServer.c:238:WebServer state WAIT_FOR_NETWORK -> SETUP
2025-11-01T09:35:07.277Z:USER:taskWebServer.c:360:WebServer started on port 443
2025-11-01T09:35:07.285Z:INFO:taskWebServer.c:238:WebServer state SETUP -> AVAILABLE
2025-11-01T09:35:09.718Z:INFO:comConnect.c:1107:Connecting wired to: ws://192.168.178.160:9000/VAN_01971, prio #1
2025-11-01T09:35:09.730Z:USER:taskMaster.c:1359:NFC version: ICU NFC 243B (v3) v3.1-531
2025-11-01T09:35:09.738Z:INFO:taskNFCreader.c:115:Port #0 version response: "ICU NFC 243B (v3) v3.1-531"
2025-11-01T09:35:09.750Z:INFO:comConnect.c:664:connection attempt 1/3
2025-11-01T09:35:09.757Z:INFO:comConnect.c:295:Connectivity state: INITIALISING
2025-11-01T09:35:09.765Z:USER:application.c:718:Initialisation done
2025-11-01T09:35:09.777Z:INFO:comConnect.c:295:Connectivity state: WIRED
2025-11-01T09:35:09.792Z:INFO:taskTCPIP.c:1526:'al' is configured as default internet connection.
2025-11-01T09:35:09.804Z:INFO:taskTCPIP.c:1543:Renew DHCP leash for interface 'al'.
2025-11-01T09:35:09.812Z:USER:comConnect.c:383:wired connect
2025-11-01T09:35:09.820Z:INFO:websockets.c:451:Connected to Socket 192.168.178.160:9000
2025-11-01T09:35:09.832Z:INFO:websockets.c:2363:WS timeout: 10000 ms
2025-11-01T09:35:09.847Z:INFO:websockets.c:824:WebSocket upgrade successful
2025-11-01T09:35:09.863Z:USER:taskOCPP.c:464:Back office connection available
2025-11-01T09:35:09.902Z:INFO:taskNFCreader.c:131:Port #0 ICU NFC reader BL3 v3.1, 1 LEDs
2025-11-01T09:35:09.910Z:INFO:taskNFCreader.c:132:Port #0 reader model: Giro-e
2025-11-01T09:35:11.976Z:INFO:modem.c:1124:Modem state InitHw->InitModem
2025-11-01T09:35:11.984Z:INFO:modem.c:1296:Reset delay 2s
2025-11-01T09:35:12.742Z:INFO:taskMaster.c:1137:Socket #1 has a Modbus meter
2025-11-01T09:35:12.750Z:INFO:updatefirmware.c:52:BL FWU_STATUS_INACTIVE -> int IDLE
2025-11-01T09:35:12.761Z:INFO:taskMain.c:1673:Socket #1: recovered AVAILABLE
2025-11-01T09:35:12.769Z:USER:taskMaster.c:1164:1 NFC readers found
2025-11-01T09:35:12.796Z:INFO:taskMaster.c:1575:Socket #1: no open transaction
2025-11-01T09:35:12.839Z:INFO:smartMeter.c:80:Set phases: (L1, L2, L3)->(L1, L2, L3)
2025-11-01T09:35:12.851Z:INFO:active_lb.c:308:SMt:(0.0 0.0 0.0)A Free:(16.0 16.0 16.0)A ALB:(0.0 0.0 0.0)A
2025-11-01T09:35:12.863Z:INFO:taskMaster.c:4957:Socket #1: state main : AVAILABLE
2025-11-01T09:35:12.878Z:INFO:taskMain.c:6440:Socket #1: active tag cleared
2025-11-01T09:35:12.921Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T09:35:12.929Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-01T09:35:12.937Z:INFO:taskMaster.c:4979:Socket #1: state led : AVAILABLE
2025-11-01T09:35:12.996Z:INFO:taskMaster.c:6376:Socket #1: no schedule
2025-11-01T09:35:13.003Z:USER:taskMaster.c:6402:Socket #1: external current limit 16.0 A
2025-11-01T09:35:13.015Z:INFO:station.c:97:station external max - new value: 99.9A
2025-11-01T09:35:13.023Z:INFO:comFaults.c:482:Reset fault status
2025-11-01T09:35:13.035Z:USER:taskMaster.c:1359:NFC version: ICU NFC 243B (v3) v3.1-531
2025-11-01T09:35:13.789Z:INFO:taskMain.c:1419:Socket #1: main state: AVAILABLE, CP: 0.0/0.0, no tag
2025-11-01T09:35:14.878Z:COM:ocpp_rpc.c:704:-> [2,"1","BootNotification",{"chargePointVendor":"Alfen BV","chargePointModel":
2025-11-01T09:35:14.878Z:COM:ocpp_rpc.c:704:"NG910-60583","chargePointSerialNumber":"ACE0640314","chargeBoxSerialNumber":"VA
2025-11-01T09:35:14.878Z:COM:ocpp_rpc.c:704:N_01971","firmwareVersion":"7.3.0-4377"}]
2025-11-01T09:35:14.914Z:COM:ocpp_rpc.c:1297:<- [3,"1",{"currentTime":"2025-11-01T09:35:15Z","interval":3600,"status":"Accept
2025-11-01T09:35:14.914Z:COM:ocpp_rpc.c:1297:ed"}]
2025-11-01T09:35:14.933Z:COM:ocpp_rpc.c:1297:<- [2,"81d0a9d8-ca65-4f33-84dc-46d0b4a73aab","GetConfiguration",{"key":["Support
2025-11-01T09:35:14.933Z:COM:ocpp_rpc.c:1297:edFeatureProfiles"]}]
2025-11-01T09:35:14.953Z:COM:ocpp_rpc.c:704:-> [3,"81d0a9d8-ca65-4f33-84dc-46d0b4a73aab",{"configurationKey":[{"key":"Suppor
2025-11-01T09:35:14.953Z:COM:ocpp_rpc.c:704:tedFeatureProfiles","readonly":true,"value":"Core,FirmwareManagement,Reservation
2025-11-01T09:35:14.953Z:COM:ocpp_rpc.c:704:,LocalAuthListManagement,RemoteTrigger,SmartCharging"}]}]
2025-11-01T09:35:14.992Z:COM:ocpp_rpc.c:1297:<- [2,"117f07cc-df29-473a-af70-4536c778817d","GetConfiguration",{"key":["NumberO
2025-11-01T09:35:14.992Z:COM:ocpp_rpc.c:1297:fConnectors"]}]
2025-11-01T09:35:15.011Z:COM:ocpp_rpc.c:704:-> [3,"117f07cc-df29-473a-af70-4536c778817d",{"configurationKey":[{"key":"Number
2025-11-01T09:35:15.011Z:COM:ocpp_rpc.c:704:OfConnectors","readonly":true,"value":"1"}]}]
2025-11-01T09:35:15.035Z:COM:ocpp_rpc.c:1297:<- [2,"90e78d31-2011-4c77-b332-bc80e53a7b45","GetConfiguration",{"key":["Heartbe
2025-11-01T09:35:15.035Z:COM:ocpp_rpc.c:1297:atInterval"]}]
2025-11-01T09:35:15.054Z:COM:ocpp_rpc.c:704:-> [3,"90e78d31-2011-4c77-b332-bc80e53a7b45",{"configurationKey":[{"key":"Heartb
2025-11-01T09:35:15.054Z:COM:ocpp_rpc.c:704:eatInterval","readonly":false,"value":"3600"}]}]
2025-11-01T09:35:15.078Z:COM:ocpp_rpc.c:1297:<- [2,"b06c8b62-70b5-45bb-9ac3-0ad593621445","ChangeConfiguration",{"key":"Meter
2025-11-01T09:35:15.078Z:COM:ocpp_rpc.c:1297:ValuesSampledData","value":"Current.Offered,Energy.Active.Import.Register,Freque
2025-11-01T09:35:15.078Z:COM:ocpp_rpc.c:1297:ncy,Power.Active.Import,Power.Factor,Temperature"}]
2025-11-01T09:35:15.117Z:COM:ocpp_rpc.c:704:-> [3,"b06c8b62-70b5-45bb-9ac3-0ad593621445",{"status":"Accepted"}]
2025-11-01T09:35:15.128Z:COM:ocpp_rpc.c:1297:<- [2,"9b43ef41-b80f-45d4-9dea-b7295cc926d6","GetConfiguration",{"key":["MeterVa
2025-11-01T09:35:15.128Z:COM:ocpp_rpc.c:1297:luesSampledData"]}]
2025-11-01T09:35:15.152Z:COM:ocpp_rpc.c:704:-> [3,"9b43ef41-b80f-45d4-9dea-b7295cc926d6",{"configurationKey":[{"key":"MeterV
2025-11-01T09:35:15.152Z:COM:ocpp_rpc.c:704:aluesSampledData","readonly":false,"value":"Current.Offered,Energy.Active.Import
2025-11-01T09:35:15.152Z:COM:ocpp_rpc.c:704:.Register,Frequency,Power.Active.Import,Power.Factor,Temperature"}]}]
2025-11-01T09:35:15.187Z:COM:ocpp_rpc.c:1297:<- [2,"826a312d-0627-4a19-8fca-93fcf3c17b44","GetConfiguration",{"key":["MeterVa
2025-11-01T09:35:15.187Z:COM:ocpp_rpc.c:1297:luesSampledData"]}]
2025-11-01T09:35:15.210Z:COM:ocpp_rpc.c:704:-> [3,"826a312d-0627-4a19-8fca-93fcf3c17b44",{"configurationKey":[{"key":"MeterV
2025-11-01T09:35:15.210Z:COM:ocpp_rpc.c:704:aluesSampledData","readonly":false,"value":"Current.Offered,Energy.Active.Import
2025-11-01T09:35:15.210Z:COM:ocpp_rpc.c:704:.Register,Frequency,Power.Active.Import,Power.Factor,Temperature"}]}]
2025-11-01T09:35:15.250Z:COM:ocpp_rpc.c:1297:<- [2,"2d4f4c2c-079c-41e0-bd20-34433e32834b","GetConfiguration",{"key":["MeterVa
2025-11-01T09:35:15.250Z:COM:ocpp_rpc.c:1297:lueSampleInterval"]}]
2025-11-01T09:35:15.269Z:COM:ocpp_rpc.c:704:-> [3,"2d4f4c2c-079c-41e0-bd20-34433e32834b",{"configurationKey":[{"key":"MeterV
2025-11-01T09:35:15.269Z:COM:ocpp_rpc.c:704:alueSampleInterval","readonly":false,"value":"900"}]}]
2025-11-01T09:35:15.296Z:COM:ocpp_rpc.c:1297:<- [2,"ba4ac691-b254-4991-afed-b3e2267977ed","ChangeConfiguration",{"key":"Meter
2025-11-01T09:35:15.296Z:COM:ocpp_rpc.c:1297:ValueSampleInterval","value":"60"}]
2025-11-01T09:35:15.316Z:COM:ocpp_rpc.c:704:-> [3,"ba4ac691-b254-4991-afed-b3e2267977ed",{"status":"Accepted"}]
2025-11-01T09:35:15.328Z:COM:ocpp_rpc.c:1297:<- [2,"501e59ae-7ea0-467d-8fbc-b900ff65e30c","GetConfiguration",{"key":["ClockAl
2025-11-01T09:35:15.328Z:COM:ocpp_rpc.c:1297:ignedDataInterval"]}]
2025-11-01T09:35:15.351Z:COM:ocpp_rpc.c:704:-> [3,"501e59ae-7ea0-467d-8fbc-b900ff65e30c",{"configurationKey":[{"key":"ClockA
2025-11-01T09:35:15.351Z:COM:ocpp_rpc.c:704:lignedDataInterval","readonly":false,"value":"0"}]}]
2025-11-01T09:35:15.375Z:COM:ocpp_rpc.c:1297:<- [2,"9795baf4-cd4d-4000-8ad3-9e025a4dbf49","ChangeConfiguration",{"key":"Clock
2025-11-01T09:35:15.375Z:COM:ocpp_rpc.c:1297:AlignedDataInterval","value":"900"}]
2025-11-01T09:35:15.398Z:COM:ocpp_rpc.c:704:-> [3,"9795baf4-cd4d-4000-8ad3-9e025a4dbf49",{"status":"Accepted"}]
2025-11-01T09:35:15.410Z:COM:ocpp_rpc.c:1297:<- [2,"abace0fb-cc86-4db5-be15-2b49b9abddb1","ChangeAvailability",{"connectorId"
2025-11-01T09:35:15.410Z:COM:ocpp_rpc.c:1297::0,"type":"Operative"}]
2025-11-01T09:35:15.628Z:COM:ocpp_rpc.c:704:-> [3,"abace0fb-cc86-4db5-be15-2b49b9abddb1",{"status":"Accepted"}]
2025-11-01T09:35:15.652Z:COM:ocpp_rpc.c:1297:<- [2,"77d0b1db-aede-4b76-9c7a-9167415eff5f","TriggerMessage",{"requestedMessage
2025-11-01T09:35:15.652Z:COM:ocpp_rpc.c:1297:":"StatusNotification","connectorId":1}]
2025-11-01T09:35:15.671Z:COM:ocpp_rpc.c:704:-> [3,"77d0b1db-aede-4b76-9c7a-9167415eff5f",{"status":"Rejected"}]
2025-11-01T09:35:15.718Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-01T09:35:15.777Z:INFO:taskCANopen.c:1787:Updated object 0x2087, 4 bytes
2025-11-01T09:35:15.804Z:INFO:taskCANopen.c:1787:Updated object 0x2098, 36 bytes
2025-11-01T09:35:15.828Z:INFO:taskCANopen.c:1787:Updated object 0x209a, 4 bytes
2025-11-01T09:35:16.042Z:INFO:taskMaster.c:5967:Socket #1: next clock aligned metervalue in 584 seconds
2025-11-01T09:35:16.179Z:USER:modem.c:3611:Modem type: Quectel BG95-M3
2025-11-01T09:35:16.199Z:INFO:modem.c:3090:Check if modem responds
2025-11-01T09:35:16.238Z:INFO:modem.c:2977:Set flow control (on)
2025-11-01T09:35:16.410Z:INFO:modem.c:3130:Set type of logging
2025-11-01T09:35:20.519Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T09:35:21.007Z:SECURITY:httpd_login.c:155:WebClient RadomskiR connected (account: admin)
2025-11-01T09:35:22.835Z:SECURITY:web_functionalit:68:Changed '2187_00' from 1761981164673 => 1761989722905
2025-11-01T09:35:23.093Z:INFO:comFaults.c:1075:#phases: socket #1 ''->'L1L2L3'
2025-11-01T09:35:23.761Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-01T09:35:24.019Z:INFO:taskCANopen.c:1787:Updated object 0x2187, 8 bytes
2025-11-01T09:35:25.183Z:COM:ocpp_rpc.c:704:-> [2,"2","StartTransaction",{"timestamp":"2025-10-31T16:40:37Z","connectorId":1
2025-11-01T09:35:25.183Z:COM:ocpp_rpc.c:704:,"meterStart":5540316,"idTag":"04BB29EAFD0F94"}]
2025-11-01T09:35:25.207Z:COM:ocpp_rpc.c:1297:<- [3,"2",{"transactionId":1761989725,"idTagInfo":{"status":"Accepted"}}]
2025-11-01T09:35:25.218Z:INFO:db_transaction.c:16:Updated TransactionStart for socket 1 at 0x00001936 (ts: 2025-10-31 16:40:37)
2025-11-01T09:35:25.242Z:USER:tag.c:1830:Tag 04BB29EAFD0F94 is authorised by server, white list updated
2025-11-01T09:35:25.257Z:INFO:db_transaction.c:16:Updated TransactionStop for socket 1 at 0x00001eaa (ts: 2025-11-01 07:14:15)
2025-11-01T09:35:25.273Z:COM:ocpp_rpc.c:704:-> [2,"3","StatusNotification",{"connectorId":0,"errorCode":"NoError","status":"
2025-11-01T09:35:25.273Z:COM:ocpp_rpc.c:704:Available"}]
2025-11-01T09:35:25.292Z:COM:ocpp_rpc.c:1297:<- [3,"3",{}]
2025-11-01T09:35:25.300Z:COM:ocpp_rpc.c:704:-> [2,"4","StatusNotification",{"connectorId":1,"errorCode":"NoError","status":"
2025-11-01T09:35:25.300Z:COM:ocpp_rpc.c:704:Available"}]
2025-11-01T09:35:25.320Z:COM:ocpp_rpc.c:1297:<- [3,"4",{}]
2025-11-01T09:35:25.359Z:COM:ocpp_rpc.c:704:-> [2,"5","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue"
2025-11-01T09:35:25.359Z:COM:ocpp_rpc.c:704::[{"timestamp":"2025-10-31T16:40:37Z","sampledValue":[{"value":"5540.316","conte
2025-11-01T09:35:25.359Z:COM:ocpp_rpc.c:704:xt":"Transaction.Begin","unit":"kWh"}]}]}]
2025-11-01T09:35:25.394Z:COM:ocpp_rpc.c:1297:<- [3,"5",{}]
2025-11-01T09:35:25.500Z:COM:ocpp_rpc.c:704:-> [2,"6","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue"
2025-11-01T09:35:25.500Z:COM:ocpp_rpc.c:704::[{"timestamp":"2025-10-31T16:40:39Z","sampledValue":[{"value":"5540.316","conte
2025-11-01T09:35:25.500Z:COM:ocpp_rpc.c:704:xt":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"Ou
2025-11-01T09:35:25.500Z:COM:ocpp_rpc.c:704:tlet","unit":"kWh"}]}]}]
2025-11-01T09:35:25.542Z:COM:ocpp_rpc.c:1297:<- [3,"6",{}]
2025-11-01T09:35:25.648Z:COM:ocpp_rpc.c:704:-> [2,"7","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue"
2025-11-01T09:35:25.648Z:COM:ocpp_rpc.c:704::[{"timestamp":"2025-10-31T16:55:38Z","sampledValue":[{"value":"5542.386","conte
2025-11-01T09:35:25.648Z:COM:ocpp_rpc.c:704:xt":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"Ou
2025-11-01T09:35:25.648Z:COM:ocpp_rpc.c:704:tlet","unit":"kWh"}]}]}]
2025-11-01T09:35:25.695Z:COM:ocpp_rpc.c:1297:<- [3,"7",{}]
2025-11-01T09:35:25.808Z:COM:ocpp_rpc.c:704:-> [2,"8","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue"
2025-11-01T09:35:25.808Z:COM:ocpp_rpc.c:704::[{"timestamp":"2025-10-31T17:10:39Z","sampledValue":[{"value":"5544.580","conte
2025-11-01T09:35:25.808Z:COM:ocpp_rpc.c:704:xt":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"Ou
2025-11-01T09:35:25.808Z:COM:ocpp_rpc.c:704:tlet","unit":"kWh"}]}]}]
2025-11-01T09:35:25.855Z:COM:ocpp_rpc.c:1297:<- [3,"8",{}]
2025-11-01T09:35:25.960Z:COM:ocpp_rpc.c:704:-> [2,"9","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue"
2025-11-01T09:35:25.960Z:COM:ocpp_rpc.c:704::[{"timestamp":"2025-10-31T17:25:38Z","sampledValue":[{"value":"5546.672","conte
2025-11-01T09:35:25.960Z:COM:ocpp_rpc.c:704:xt":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"Ou
2025-11-01T09:35:25.960Z:COM:ocpp_rpc.c:704:tlet","unit":"kWh"}]}]}]
2025-11-01T09:35:26.003Z:COM:ocpp_rpc.c:1297:<- [3,"9",{}]
2025-11-01T09:35:26.109Z:COM:ocpp_rpc.c:704:-> [2,"10","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:26.109Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T17:40:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:26.109Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:26.109Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:26.156Z:COM:ocpp_rpc.c:1297:<- [3,"10",{}]
2025-11-01T09:35:26.261Z:COM:ocpp_rpc.c:704:-> [2,"11","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:26.261Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T17:55:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:26.261Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:26.261Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:26.308Z:COM:ocpp_rpc.c:1297:<- [3,"11",{}]
2025-11-01T09:35:26.414Z:COM:ocpp_rpc.c:704:-> [2,"12","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:26.414Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T18:10:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:26.414Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:26.414Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:26.457Z:COM:ocpp_rpc.c:1297:<- [3,"12",{}]
2025-11-01T09:35:26.562Z:COM:ocpp_rpc.c:704:-> [2,"13","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:26.562Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T18:25:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:26.562Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:26.562Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:26.609Z:COM:ocpp_rpc.c:1297:<- [3,"13",{}]
2025-11-01T09:35:26.714Z:COM:ocpp_rpc.c:704:-> [2,"14","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:26.714Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T18:40:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:26.714Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:26.714Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:26.761Z:COM:ocpp_rpc.c:1297:<- [3,"14",{}]
2025-11-01T09:35:26.871Z:COM:ocpp_rpc.c:704:-> [2,"15","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:26.871Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T18:55:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:26.871Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:26.871Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:26.914Z:COM:ocpp_rpc.c:1297:<- [3,"15",{}]
2025-11-01T09:35:27.023Z:COM:ocpp_rpc.c:704:-> [2,"16","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:27.023Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T19:10:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:27.023Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:27.023Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:27.070Z:COM:ocpp_rpc.c:1297:<- [3,"16",{}]
2025-11-01T09:35:27.175Z:COM:ocpp_rpc.c:704:-> [2,"17","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:27.175Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T19:25:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:27.175Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:27.175Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:27.218Z:COM:ocpp_rpc.c:1297:<- [3,"17",{}]
2025-11-01T09:35:27.328Z:COM:ocpp_rpc.c:704:-> [2,"18","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:27.328Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T19:40:39Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:27.328Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:27.328Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:27.371Z:COM:ocpp_rpc.c:1297:<- [3,"18",{}]
2025-11-01T09:35:27.476Z:COM:ocpp_rpc.c:704:-> [2,"19","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:27.476Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T19:55:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:27.476Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:27.476Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:27.523Z:COM:ocpp_rpc.c:1297:<- [3,"19",{}]
2025-11-01T09:35:27.628Z:COM:ocpp_rpc.c:704:-> [2,"20","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:27.628Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T20:10:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:27.628Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:27.628Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:27.671Z:COM:ocpp_rpc.c:1297:<- [3,"20",{}]
2025-11-01T09:35:27.785Z:COM:ocpp_rpc.c:704:-> [2,"21","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:27.785Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T20:25:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:27.785Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:27.785Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:27.832Z:COM:ocpp_rpc.c:1297:<- [3,"21",{}]
2025-11-01T09:35:27.937Z:COM:ocpp_rpc.c:704:-> [2,"22","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:27.937Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T20:40:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:27.937Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:27.937Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:27.984Z:COM:ocpp_rpc.c:1297:<- [3,"22",{}]
2025-11-01T09:35:28.089Z:COM:ocpp_rpc.c:704:-> [2,"23","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:28.089Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T20:55:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:28.089Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:28.089Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:28.136Z:COM:ocpp_rpc.c:1297:<- [3,"23",{}]
2025-11-01T09:35:28.242Z:COM:ocpp_rpc.c:704:-> [2,"24","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:28.242Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T21:10:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:28.242Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:28.242Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:28.289Z:COM:ocpp_rpc.c:1297:<- [3,"24",{}]
2025-11-01T09:35:28.394Z:COM:ocpp_rpc.c:704:-> [2,"25","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:28.394Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T21:25:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:28.394Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:28.394Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:28.437Z:COM:ocpp_rpc.c:1297:<- [3,"25",{}]
2025-11-01T09:35:28.546Z:COM:ocpp_rpc.c:704:-> [2,"26","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:28.546Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T21:40:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:28.546Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:28.546Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:28.589Z:COM:ocpp_rpc.c:1297:<- [3,"26",{}]
2025-11-01T09:35:28.699Z:COM:ocpp_rpc.c:704:-> [2,"27","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:28.699Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T21:55:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:28.699Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:28.699Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:28.746Z:COM:ocpp_rpc.c:1297:<- [3,"27",{}]
2025-11-01T09:35:28.855Z:COM:ocpp_rpc.c:704:-> [2,"28","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:28.855Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T22:10:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:28.855Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:28.855Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:28.902Z:COM:ocpp_rpc.c:1297:<- [3,"28",{}]
2025-11-01T09:35:29.007Z:COM:ocpp_rpc.c:704:-> [2,"29","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:29.007Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T22:25:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:29.007Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:29.007Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:29.054Z:COM:ocpp_rpc.c:1297:<- [3,"29",{}]
2025-11-01T09:35:29.160Z:COM:ocpp_rpc.c:704:-> [2,"30","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:29.160Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T22:40:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:29.160Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:29.160Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:29.207Z:COM:ocpp_rpc.c:1297:<- [3,"30",{}]
2025-11-01T09:35:29.312Z:COM:ocpp_rpc.c:704:-> [2,"31","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:29.312Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T22:55:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:29.312Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:29.312Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:29.355Z:COM:ocpp_rpc.c:1297:<- [3,"31",{}]
2025-11-01T09:35:29.464Z:COM:ocpp_rpc.c:704:-> [2,"32","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:29.464Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T23:10:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:29.464Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:29.464Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:29.511Z:COM:ocpp_rpc.c:1297:<- [3,"32",{}]
2025-11-01T09:35:29.617Z:COM:ocpp_rpc.c:704:-> [2,"33","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:29.617Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T23:25:39Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:29.617Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:29.617Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:29.664Z:COM:ocpp_rpc.c:1297:<- [3,"33",{}]
2025-11-01T09:35:29.792Z:COM:ocpp_rpc.c:704:-> [2,"34","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:29.792Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T23:40:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:29.792Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:29.792Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:29.839Z:COM:ocpp_rpc.c:1297:<- [3,"34",{}]
2025-11-01T09:35:29.949Z:COM:ocpp_rpc.c:704:-> [2,"35","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:29.949Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-10-31T23:55:38Z","sampledValue":[{"value":"5548.035","cont
2025-11-01T09:35:29.949Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:29.949Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:29.992Z:COM:ocpp_rpc.c:1297:<- [3,"35",{}]
2025-11-01T09:35:30.101Z:COM:ocpp_rpc.c:704:-> [2,"36","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:30.101Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T00:10:38Z","sampledValue":[{"value":"5548.621","cont
2025-11-01T09:35:30.101Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:30.101Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:30.148Z:COM:ocpp_rpc.c:1297:<- [3,"36",{}]
2025-11-01T09:35:30.257Z:COM:ocpp_rpc.c:704:-> [2,"37","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:30.257Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T00:25:39Z","sampledValue":[{"value":"5548.621","cont
2025-11-01T09:35:30.257Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:30.257Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:30.300Z:COM:ocpp_rpc.c:1297:<- [3,"37",{}]
2025-11-01T09:35:30.406Z:COM:ocpp_rpc.c:704:-> [2,"38","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:30.406Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T00:40:38Z","sampledValue":[{"value":"5548.621","cont
2025-11-01T09:35:30.406Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:30.406Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:30.453Z:COM:ocpp_rpc.c:1297:<- [3,"38",{}]
2025-11-01T09:35:30.562Z:COM:ocpp_rpc.c:704:-> [2,"39","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:30.562Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T00:55:38Z","sampledValue":[{"value":"5548.621","cont
2025-11-01T09:35:30.562Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:30.562Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:30.605Z:COM:ocpp_rpc.c:1297:<- [3,"39",{}]
2025-11-01T09:35:30.714Z:COM:ocpp_rpc.c:704:-> [2,"40","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:30.714Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T01:10:38Z","sampledValue":[{"value":"5549.452","cont
2025-11-01T09:35:30.714Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:30.714Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:30.761Z:COM:ocpp_rpc.c:1297:<- [3,"40",{}]
2025-11-01T09:35:30.871Z:COM:ocpp_rpc.c:704:-> [2,"41","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:30.871Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T01:25:38Z","sampledValue":[{"value":"5551.081","cont
2025-11-01T09:35:30.871Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:30.871Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:30.914Z:COM:ocpp_rpc.c:1297:<- [3,"41",{}]
2025-11-01T09:35:31.023Z:COM:ocpp_rpc.c:704:-> [2,"42","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:31.023Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T01:40:38Z","sampledValue":[{"value":"5553.323","cont
2025-11-01T09:35:31.023Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:31.023Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:31.070Z:COM:ocpp_rpc.c:1297:<- [3,"42",{}]
2025-11-01T09:35:31.179Z:COM:ocpp_rpc.c:704:-> [2,"43","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:31.179Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T01:55:38Z","sampledValue":[{"value":"5555.846","cont
2025-11-01T09:35:31.179Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:31.179Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:31.222Z:COM:ocpp_rpc.c:1297:<- [3,"43",{}]
2025-11-01T09:35:31.332Z:COM:ocpp_rpc.c:704:-> [2,"44","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:31.332Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T02:10:38Z","sampledValue":[{"value":"5558.138","cont
2025-11-01T09:35:31.332Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:31.332Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:31.375Z:COM:ocpp_rpc.c:1297:<- [3,"44",{}]
2025-11-01T09:35:31.480Z:COM:ocpp_rpc.c:704:-> [2,"45","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:31.480Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T02:25:38Z","sampledValue":[{"value":"5560.275","cont
2025-11-01T09:35:31.480Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:31.480Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:31.527Z:COM:ocpp_rpc.c:1297:<- [3,"45",{}]
2025-11-01T09:35:31.644Z:COM:ocpp_rpc.c:704:-> [2,"46","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:31.644Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T02:40:38Z","sampledValue":[{"value":"5562.812","cont
2025-11-01T09:35:31.644Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:31.644Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:31.722Z:COM:ocpp_rpc.c:1297:<- [3,"46",{}]
2025-11-01T09:35:31.839Z:COM:ocpp_rpc.c:704:-> [2,"47","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:31.839Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T02:55:38Z","sampledValue":[{"value":"5563.678","cont
2025-11-01T09:35:31.839Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:31.839Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:31.886Z:COM:ocpp_rpc.c:1297:<- [3,"47",{}]
2025-11-01T09:35:32.003Z:COM:ocpp_rpc.c:704:-> [2,"48","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:32.003Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T03:10:38Z","sampledValue":[{"value":"5564.969","cont
2025-11-01T09:35:32.003Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:32.003Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:32.046Z:COM:ocpp_rpc.c:1297:<- [3,"48",{}]
2025-11-01T09:35:32.167Z:COM:ocpp_rpc.c:704:-> [2,"49","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:32.167Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T03:25:38Z","sampledValue":[{"value":"5567.483","cont
2025-11-01T09:35:32.167Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:32.167Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:32.214Z:COM:ocpp_rpc.c:1297:<- [3,"49",{}]
2025-11-01T09:35:32.332Z:COM:ocpp_rpc.c:704:-> [2,"50","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:32.332Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T03:40:38Z","sampledValue":[{"value":"5570.004","cont
2025-11-01T09:35:32.332Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:32.332Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:32.375Z:COM:ocpp_rpc.c:1297:<- [3,"50",{}]
2025-11-01T09:35:32.496Z:COM:ocpp_rpc.c:704:-> [2,"51","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:32.496Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T03:55:38Z","sampledValue":[{"value":"5571.247","cont
2025-11-01T09:35:32.496Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:32.496Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:32.539Z:COM:ocpp_rpc.c:1297:<- [3,"51",{}]
2025-11-01T09:35:32.660Z:COM:ocpp_rpc.c:704:-> [2,"52","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:32.660Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T04:10:38Z","sampledValue":[{"value":"5571.836","cont
2025-11-01T09:35:32.660Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:32.660Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:32.703Z:COM:ocpp_rpc.c:1297:<- [3,"52",{}]
2025-11-01T09:35:32.832Z:COM:ocpp_rpc.c:704:-> [2,"53","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:32.832Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T04:25:38Z","sampledValue":[{"value":"5573.281","cont
2025-11-01T09:35:32.832Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:32.832Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:32.878Z:COM:ocpp_rpc.c:1297:<- [3,"53",{}]
2025-11-01T09:35:33.000Z:COM:ocpp_rpc.c:704:-> [2,"54","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:33.000Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T04:40:38Z","sampledValue":[{"value":"5574.919","cont
2025-11-01T09:35:33.000Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:33.000Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:33.046Z:COM:ocpp_rpc.c:1297:<- [3,"54",{}]
2025-11-01T09:35:33.164Z:COM:ocpp_rpc.c:704:-> [2,"55","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:33.164Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T04:55:38Z","sampledValue":[{"value":"5576.427","cont
2025-11-01T09:35:33.164Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:33.164Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:33.210Z:COM:ocpp_rpc.c:1297:<- [3,"55",{}]
2025-11-01T09:35:33.328Z:COM:ocpp_rpc.c:704:-> [2,"56","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:33.328Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T05:10:38Z","sampledValue":[{"value":"5578.320","cont
2025-11-01T09:35:33.328Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:33.328Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:33.375Z:COM:ocpp_rpc.c:1297:<- [3,"56",{}]
2025-11-01T09:35:33.488Z:COM:ocpp_rpc.c:704:-> [2,"57","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:33.488Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T05:25:38Z","sampledValue":[{"value":"5580.255","cont
2025-11-01T09:35:33.488Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:33.488Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:33.535Z:COM:ocpp_rpc.c:1297:<- [3,"57",{}]
2025-11-01T09:35:33.652Z:COM:ocpp_rpc.c:704:-> [2,"58","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:33.652Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T05:40:38Z","sampledValue":[{"value":"5582.202","cont
2025-11-01T09:35:33.652Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:33.652Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:33.699Z:COM:ocpp_rpc.c:1297:<- [3,"58",{}]
2025-11-01T09:35:33.824Z:COM:ocpp_rpc.c:704:-> [2,"59","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:33.824Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T05:55:38Z","sampledValue":[{"value":"5584.129","cont
2025-11-01T09:35:33.824Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:33.824Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:33.871Z:COM:ocpp_rpc.c:1297:<- [3,"59",{}]
2025-11-01T09:35:33.992Z:COM:ocpp_rpc.c:704:-> [2,"60","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:33.992Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T06:10:38Z","sampledValue":[{"value":"5586.061","cont
2025-11-01T09:35:33.992Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:33.992Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:34.035Z:COM:ocpp_rpc.c:1297:<- [3,"60",{}]
2025-11-01T09:35:34.156Z:COM:ocpp_rpc.c:704:-> [2,"61","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:34.156Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T06:25:39Z","sampledValue":[{"value":"5587.987","cont
2025-11-01T09:35:34.156Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:34.156Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:34.199Z:COM:ocpp_rpc.c:1297:<- [3,"61",{}]
2025-11-01T09:35:34.308Z:COM:ocpp_rpc.c:704:-> [2,"62","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:34.308Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T06:40:38Z","sampledValue":[{"value":"5588.146","cont
2025-11-01T09:35:34.308Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:34.308Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:34.355Z:COM:ocpp_rpc.c:1297:<- [3,"62",{}]
2025-11-01T09:35:34.464Z:COM:ocpp_rpc.c:704:-> [2,"63","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:34.464Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T06:55:38Z","sampledValue":[{"value":"5588.146","cont
2025-11-01T09:35:34.464Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:34.464Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:34.507Z:COM:ocpp_rpc.c:1297:<- [3,"63",{}]
2025-11-01T09:35:34.617Z:COM:ocpp_rpc.c:704:-> [2,"64","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:34.617Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T07:10:38Z","sampledValue":[{"value":"5588.146","cont
2025-11-01T09:35:34.617Z:COM:ocpp_rpc.c:704:ext":"Sample.Periodic","measurand":"Energy.Active.Import.Register","location":"O
2025-11-01T09:35:34.617Z:COM:ocpp_rpc.c:704:utlet","unit":"kWh"}]}]}]
2025-11-01T09:35:34.664Z:COM:ocpp_rpc.c:1297:<- [3,"64",{}]
2025-11-01T09:35:34.753Z:COM:ocpp_rpc.c:704:-> [2,"65","MeterValues",{"connectorId":1,"transactionId":1761989725,"meterValue
2025-11-01T09:35:34.753Z:COM:ocpp_rpc.c:704:":[{"timestamp":"2025-11-01T07:14:15Z","sampledValue":[{"value":"5588.146","cont
2025-11-01T09:35:34.753Z:COM:ocpp_rpc.c:704:ext":"Transaction.End","unit":"kWh"}]}]}]
2025-11-01T09:35:34.785Z:COM:ocpp_rpc.c:1297:<- [3,"65",{}]
2025-11-01T09:35:34.867Z:COM:ocpp_rpc.c:704:-> [2,"66","StopTransaction",{"timestamp":"2025-11-01T07:14:15Z","transactionId"
2025-11-01T09:35:34.867Z:COM:ocpp_rpc.c:704::1761989725,"meterStop":5588146,"idTag":"04BB29EAFD0F94","reason":"Local","trans
2025-11-01T09:35:34.867Z:COM:ocpp_rpc.c:704:actionData":[{"timestamp":"2025-10-31T16:40:37Z","sampledValue":[{"value":"5540.
2025-11-01T09:35:34.867Z:COM:ocpp_rpc.c:704:316","context":"Transaction.Begin","unit":"kWh"}]},{"timestamp":"2025-11-01T07:1
2025-11-01T09:35:34.867Z:COM:ocpp_rpc.c:704:4:15Z","sampledValue":[{"value":"5588.146","context":"Transaction.End","unit":"k
2025-11-01T09:35:34.867Z:COM:ocpp_rpc.c:704:Wh"}]}]}]
2025-11-01T09:35:34.937Z:INFO:modem.c:2525:Check PIN
2025-11-01T09:35:34.945Z:COM:ocpp_rpc.c:1297:<- [3,"66",{"idTagInfo":{"status":"Accepted"}}]
2025-11-01T09:35:34.953Z:INFO:db_transaction.c:16:Updated TransactionStop for socket 1 at 0x00001eaa (ts: 2025-11-01 07:14:15)
2025-11-01T09:35:34.980Z:USER:tag.c:1830:Tag 04BB29EAFD0F94 is authorised by server, white list updated
2025-11-01T09:35:38.718Z:WARNING:modem.c:2562:SIM error
2025-11-01T09:35:42.593Z:WARNING:modem.c:2562:SIM error
2025-11-01T09:35:43.625Z:INFO:taskWifi.c:671:WiFi Module: Not Initialized --> Disabled
2025-11-01T09:35:46.472Z:WARNING:modem.c:2562:SIM error
2025-11-01T09:35:46.933Z:WARNING:taskWebClient.c:234:Client (fd=2) disconnected (r: -0x50)
2025-11-01T09:35:46.945Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T09:35:46.968Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T09:35:49.343Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T09:35:49.402Z:SECURITY:taskWebClient.c:446:Received unauthorized request, so removing client
2025-11-01T09:35:49.414Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T09:35:49.472Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T09:35:50.347Z:WARNING:modem.c:2562:SIM error
2025-11-01T09:35:50.453Z:INFO:modem.c:2572:Check PIN failed
2025-11-01T09:35:51.253Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T09:35:51.902Z:SECURITY:httpd_login.c:155:WebClient RadomskiR connected (account: admin)
2025-11-01T09:36:05.593Z:INFO:modem.c:3291:Get other info
2025-11-01T09:36:38.699Z:WARNING:modem.c:2725:AT+CSQ, invalid value(99)
2025-11-01T09:37:10.679Z:INFO:modem.c:3313:Signal strength : Unknown
2025-11-01T09:37:10.687Z:INFO:modem.c:3315:Radio Access Tech : 4G
2025-11-01T09:37:10.695Z:INFO:modem.c:3316:Registration mode : Disabled
2025-11-01T09:37:10.703Z:INFO:modem.c:3317:Registration status: Not registered
2025-11-01T09:37:10.710Z:INFO:modem.c:3318:Operator : 0
2025-11-01T09:37:10.718Z:INFO:modem.c:3319:Manufacturer : Quectel
2025-11-01T09:37:10.726Z:INFO:modem.c:3320:Modem module : BG95-M3
2025-11-01T09:37:10.734Z:INFO:modem.c:3321:Modem revision : BG95M3LAR02A03_01.012.01.012
2025-11-01T09:37:10.746Z:INFO:modem.c:3322:Modem IMEI : 864145067568848
2025-11-01T09:37:10.753Z:INFO:modem.c:3323:SIM IMSI :
2025-11-01T09:37:10.761Z:INFO:modem.c:3324:SIM ICCID :
2025-11-01T09:37:10.769Z:INFO:modem.c:3325:Modem supports 2G : yes
2025-11-01T09:37:10.777Z:INFO:modem.c:3326:Modem supports 3G : no
2025-11-01T09:37:10.781Z:INFO:modem.c:3327:Modem supports 4G : yes
2025-11-01T09:37:10.832Z:INFO:modem.c:3334:Cellinfo : "SEARCH"
2025-11-01T09:37:10.839Z:ERROR:modem.c:3364:Setup modem Failed
2025-11-01T09:37:10.847Z:INFO:modem.c:1124:Modem state InitModem->Stopping
2025-11-01T09:37:19.371Z:INFO:modem.c:1124:Modem state Stopping->Idle
2025-11-01T09:38:52.148Z:SECURITY:web_functionali:105:Webserver logout client 2
2025-11-01T09:38:52.164Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T09:38:52.207Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T09:39:04.222Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T09:39:04.585Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T09:39:04.816Z:WARNING:web_functionalit:48:Failed to parse property '2068_1'
2025-11-01T09:39:04.824Z:WARNING:web_functionalit:48:Failed to parse property '2068_2'
2025-11-01T09:39:04.843Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T09:39:05.285Z:WARNING:web_functionalit:48:Failed to parse property '8006_0'
2025-11-01T09:39:05.421Z:WARNING:web_functionalit:48:Failed to parse property '8201_0'
2025-11-01T09:39:05.429Z:WARNING:web_functionalit:48:Failed to parse property '8202_0'
2025-11-01T09:39:05.441Z:WARNING:web_functionalit:48:Failed to parse property '8203_0'
2025-11-01T09:39:05.449Z:WARNING:web_functionalit:48:Failed to parse property '8301_0'
2025-11-01T09:39:05.457Z:WARNING:web_functionalit:48:Failed to parse property '8302_0'
2025-11-01T09:39:05.570Z:WARNING:web_functionalit:48:Failed to parse property '8303_0'
2025-11-01T09:39:05.578Z:WARNING:web_functionalit:48:Failed to parse property '8101_1'
2025-11-01T09:39:05.589Z:WARNING:web_functionalit:48:Failed to parse property '8101_2'
2025-11-01T09:39:05.597Z:WARNING:web_functionalit:48:Failed to parse property '8102_1'
2025-11-01T09:39:05.605Z:WARNING:web_functionalit:48:Failed to parse property '8102_2'
2025-11-01T09:39:05.617Z:WARNING:web_functionalit:48:Failed to parse property '8103_1'
2025-11-01T09:39:05.625Z:WARNING:web_functionalit:48:Failed to parse property '8103_2'
2025-11-01T09:39:05.636Z:WARNING:web_functionalit:48:Failed to parse property '8108_1'
2025-11-01T09:39:05.644Z:WARNING:web_functionalit:48:Failed to parse property '8108_2'
2025-11-01T09:39:05.656Z:WARNING:web_functionalit:48:Failed to parse property '8107_1'
2025-11-01T09:39:05.664Z:WARNING:web_functionalit:48:Failed to parse property '8107_2'
2025-11-01T09:39:05.671Z:WARNING:web_functionalit:48:Failed to parse property '810A_1'
2025-11-01T09:39:05.683Z:WARNING:web_functionalit:48:Failed to parse property '810A_2'
2025-11-01T09:39:05.691Z:WARNING:web_functionalit:48:Failed to parse property '8109_1'
2025-11-01T09:39:05.703Z:WARNING:web_functionalit:48:Failed to parse property '8109_2'
2025-11-01T09:39:05.824Z:WARNING:web_functionalit:48:Failed to parse property '2188_0'
2025-11-01T09:39:45.500Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T09:39:45.757Z:WARNING:web_functionalit:48:Failed to parse property '2068_1'
2025-11-01T09:39:45.765Z:WARNING:web_functionalit:48:Failed to parse property '2068_2'
2025-11-01T09:39:45.781Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T09:39:46.203Z:WARNING:web_functionalit:48:Failed to parse property '8006_0'
2025-11-01T09:39:46.367Z:WARNING:web_functionalit:48:Failed to parse property '8201_0'
2025-11-01T09:39:46.375Z:WARNING:web_functionalit:48:Failed to parse property '8202_0'
2025-11-01T09:39:46.386Z:WARNING:web_functionalit:48:Failed to parse property '8203_0'
2025-11-01T09:39:46.394Z:WARNING:web_functionalit:48:Failed to parse property '8301_0'
2025-11-01T09:39:46.402Z:WARNING:web_functionalit:48:Failed to parse property '8302_0'
2025-11-01T09:39:46.523Z:WARNING:web_functionalit:48:Failed to parse property '8303_0'
2025-11-01T09:39:46.535Z:WARNING:web_functionalit:48:Failed to parse property '8101_1'
2025-11-01T09:39:46.542Z:WARNING:web_functionalit:48:Failed to parse property '8101_2'
2025-11-01T09:39:46.550Z:WARNING:web_functionalit:48:Failed to parse property '8102_1'
2025-11-01T09:39:46.562Z:WARNING:web_functionalit:48:Failed to parse property '8102_2'
2025-11-01T09:39:46.570Z:WARNING:web_functionalit:48:Failed to parse property '8103_1'
2025-11-01T09:39:46.582Z:WARNING:web_functionalit:48:Failed to parse property '8103_2'
2025-11-01T09:39:46.589Z:WARNING:web_functionalit:48:Failed to parse property '8108_1'
2025-11-01T09:39:46.597Z:WARNING:web_functionalit:48:Failed to parse property '8108_2'
2025-11-01T09:39:46.609Z:WARNING:web_functionalit:48:Failed to parse property '8107_1'
2025-11-01T09:39:46.617Z:WARNING:web_functionalit:48:Failed to parse property '8107_2'
2025-11-01T09:39:46.625Z:WARNING:web_functionalit:48:Failed to parse property '810A_1'
2025-11-01T09:39:46.636Z:WARNING:web_functionalit:48:Failed to parse property '810A_2'
2025-11-01T09:39:46.644Z:WARNING:web_functionalit:48:Failed to parse property '8109_1'
2025-11-01T09:39:46.652Z:WARNING:web_functionalit:48:Failed to parse property '8109_2'
2025-11-01T09:39:46.789Z:WARNING:web_functionalit:48:Failed to parse property '2188_0'
2025-11-01T09:40:28.039Z:WARNING:web_functionalit:48:Failed to parse property '8201_0'
2025-11-01T09:40:28.050Z:WARNING:web_functionalit:48:Failed to parse property '8202_0'
2025-11-01T09:40:28.058Z:WARNING:web_functionalit:48:Failed to parse property '8203_0'
2025-11-01T09:40:28.070Z:WARNING:web_functionalit:48:Failed to parse property '8301_0'
2025-11-01T09:40:28.078Z:WARNING:web_functionalit:48:Failed to parse property '8302_0'
2025-11-01T09:40:28.085Z:WARNING:web_functionalit:48:Failed to parse property '8303_0'
2025-11-01T09:40:30.632Z:WARNING:web_functionalit:48:Failed to parse property '2188_0'
2025-11-01T09:40:35.730Z:WARNING:web_functionalit:48:Failed to parse property '8201_0'
2025-11-01T09:40:35.738Z:WARNING:web_functionalit:48:Failed to parse property '8202_0'
2025-11-01T09:40:35.750Z:WARNING:web_functionalit:48:Failed to parse property '8203_0'
2025-11-01T09:40:35.757Z:WARNING:web_functionalit:48:Failed to parse property '8301_0'
2025-11-01T09:40:35.769Z:WARNING:web_functionalit:48:Failed to parse property '8302_0'
2025-11-01T09:40:35.777Z:WARNING:web_functionalit:48:Failed to parse property '8303_0'
2025-11-01T09:40:59.957Z:WARNING:taskWebClient.c:234:Client (fd=2) disconnected (r: -0x0)
2025-11-01T09:40:59.968Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T09:41:00.003Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T09:41:25.007Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 1 of max 10
2025-11-01T09:42:42.425Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T09:42:43.132Z:SECURITY:httpd_login.c:155:WebClient connected (account: admin)
2025-11-01T09:42:43.230Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T09:42:54.101Z:WARNING:web_functionali:139:Could not find prop dwId 2071.01
2025-11-01T09:42:54.113Z:WARNING:web_functionali:139:Could not find prop dwId 2071.02
2025-11-01T09:42:54.121Z:WARNING:web_functionali:139:Could not find prop dwId 2078.01
2025-11-01T09:42:54.128Z:WARNING:web_functionali:139:Could not find prop dwId 2078.02
2025-11-01T09:42:54.136Z:WARNING:web_functionali:139:Could not find prop dwId 2081.00
2025-11-01T09:42:54.148Z:WARNING:web_functionali:139:Could not find prop dwId 2100.00
2025-11-01T09:42:54.156Z:WARNING:web_functionali:139:Could not find prop dwId 2101.00
2025-11-01T09:42:54.167Z:WARNING:web_functionali:139:Could not find prop dwId 2102.00
2025-11-01T09:42:54.175Z:SECURITY:web_functionalit:63:Changed '20f0_06' from 1 => 0
2025-11-01T09:42:54.183Z:SECURITY:web_functionalit:63:Changed '20f0_0e' from 1 => 0
2025-11-01T09:42:54.191Z:SECURITY:web_functionalit:63:Changed '20f0_01' from 3 => 1
2025-11-01T09:42:54.199Z:SECURITY:web_functionalit:58:Changed '20F0_03' from 'ws://192.168.178.160:9000/' => ''
2025-11-01T09:42:54.210Z:WARNING:comConnect.c:957:Interface 0 not supported
2025-11-01T09:42:54.218Z:WARNING:comConnect.c:1067:Interface 0 not supported
2025-11-01T09:42:54.230Z:USER:taskOCPP.c:503:Back office connection lost
2025-11-01T09:42:54.246Z:INFO:comConnect.c:295:Connectivity state: DISCONNECT
2025-11-01T09:42:54.265Z:USER:comConnect.c:443:wired disconnect
2025-11-01T09:42:54.292Z:INFO:comConnect.c:295:Connectivity state: INITIALISING
2025-11-01T09:42:54.312Z:INFO:comConnect.c:295:Connectivity state: STANDALONE
2025-11-01T09:42:54.960Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-01T09:42:55.187Z:INFO:taskCANopen.c:1787:Updated object 0x20f0, 1142 bytes
2025-11-01T09:42:56.476Z:SECURITY:web_functionalit:68:Changed '2187_00' from 1761989722905 => 1761990176640
2025-11-01T09:42:56.976Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-01T09:42:57.230Z:INFO:taskCANopen.c:1787:Updated object 0x2187, 8 bytes
2025-11-01T09:43:02.992Z:SECURITY:web_functionali:105:Webserver logout client 2
2025-11-01T09:43:03.015Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T09:43:03.027Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T09:45:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T09:45:12.832Z:INFO:active_lb.c:308:SMt:(2.0 2.0 2.0)A Free:(14.0 14.0 14.0)A ALB:(14.0 14.0 14.0)A
2025-11-01T09:47:50.839Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 2 of max 10
2025-11-01T09:49:56.800Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=235.2V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T09:49:57.402Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-01T09:54:16.679Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 3 of max 10
2025-11-01T09:55:12.765Z:INFO:active_lb.c:308:SMt:(2.0 2.0 2.0)A Free:(14.0 14.0 14.0)A ALB:(13.7 14.0 14.0)A
2025-11-01T10:00:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T10:00:42.507Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 4 of max 10
2025-11-01T10:04:56.707Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=235.4V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T10:04:57.855Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-01T10:05:12.703Z:INFO:active_lb.c:308:SMt:(2.0 1.0 2.0)A Free:(14.0 15.0 14.0)A ALB:(14.1 15.0 14.0)A
2025-11-01T10:07:08.335Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 5 of max 10
2025-11-01T10:13:34.175Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 6 of max 10
2025-11-01T10:15:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T10:15:12.640Z:INFO:active_lb.c:308:SMt:(2.0 1.0 2.0)A Free:(14.0 15.0 14.0)A ALB:(14.3 15.0 14.0)A
2025-11-01T10:19:56.609Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=236.8V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T10:19:58.261Z:USER:taskMaster.c:6582:Temperature: 25.9 C
2025-11-01T10:19:59.988Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 7 of max 10
2025-11-01T10:25:12.578Z:INFO:active_lb.c:308:SMt:(2.0 1.0 2.0)A Free:(14.0 15.0 14.0)A ALB:(15.4 15.0 14.0)A
2025-11-01T10:26:25.832Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 8 of max 10
2025-11-01T10:30:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T10:32:51.664Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 9 of max 10
2025-11-01T10:34:56.515Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=234.7V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T10:34:58.714Z:USER:taskMaster.c:6582:Temperature: 26.5 C
2025-11-01T10:35:12.515Z:INFO:active_lb.c:308:SMt:(2.0 6.0 2.0)A Free:(14.0 10.0 14.0)A ALB:(14.0 10.7 14.0)A
2025-11-01T10:39:17.500Z:INFO:taskDisplay.c:3809:Display not responding or not present, hard-resetting display try 10 of max 10
2025-11-01T10:45:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T10:45:12.449Z:INFO:active_lb.c:308:SMt:(-2.0 3.0 2.0)A Free:(18.0 13.0 14.0)A ALB:(17.5 13.0 14.0)A
2025-11-01T10:49:56.421Z:USER:taskMaster.c:6684:Socket #1: L1N=236.2V L2N=236.4V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T10:49:58.621Z:USER:taskMaster.c:6582:Temperature: 26.8 C
2025-11-01T10:55:12.386Z:INFO:active_lb.c:308:SMt:(2.0 3.0 2.0)A Free:(14.0 13.0 14.0)A ALB:(15.4 13.0 14.0)A
2025-11-01T11:00:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T11:04:56.328Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=235.3V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T11:04:58.777Z:USER:taskMaster.c:6582:Temperature: 26.9 C
2025-11-01T11:05:12.324Z:INFO:active_lb.c:308:SMt:(-2.0 3.0 2.0)A Free:(18.0 13.0 14.0)A ALB:(17.2 13.0 14.0)A
2025-11-01T11:15:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T11:15:12.261Z:INFO:active_lb.c:308:SMt:(2.0 3.0 2.0)A Free:(14.0 13.0 14.0)A ALB:(14.1 13.0 14.0)A
2025-11-01T11:19:56.230Z:USER:taskMaster.c:6684:Socket #1: L1N=233.3V L2N=234.8V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T11:19:58.980Z:USER:taskMaster.c:6582:Temperature: 26.9 C
2025-11-01T11:25:12.199Z:INFO:active_lb.c:308:SMt:(-2.0 3.0 2.0)A Free:(18.0 13.0 14.0)A ALB:(17.7 13.0 14.0)A
2025-11-01T11:30:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T11:34:56.136Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=235.7V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T11:34:59.437Z:USER:taskMaster.c:6582:Temperature: 27.0 C
2025-11-01T11:35:03.984Z:INFO:heap_trace.c:493:free: 69304/160768 (43.1%) min: 37040 (23.0%) alloc #: 195
2025-11-01T11:35:03.996Z:INFO:heap_trace.c:495:fragm: 40.9% 4K: 17.3% free blocks: # 14 largest: 40992
2025-11-01T11:35:12.132Z:INFO:active_lb.c:308:SMt:(3.0 2.0 2.0)A Free:(13.0 14.0 14.0)A ALB:(13.7 14.0 14.0)A
2025-11-01T11:45:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T11:45:12.070Z:INFO:active_lb.c:308:SMt:(-2.0 3.0 2.0)A Free:(18.0 13.0 14.0)A ALB:(17.2 13.0 14.0)A
2025-11-01T11:49:56.042Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=233.4V L3N=231.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T11:49:59.839Z:USER:taskMaster.c:6582:Temperature: 27.0 C
2025-11-01T11:55:12.007Z:INFO:active_lb.c:308:SMt:(-2.0 3.0 2.0)A Free:(18.0 13.0 14.0)A ALB:(17.8 13.0 14.0)A
2025-11-01T12:00:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T12:04:55.945Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=235.3V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T12:05:00.246Z:USER:taskMaster.c:6582:Temperature: 27.1 C
2025-11-01T12:05:11.945Z:INFO:active_lb.c:308:SMt:(2.0 3.0 2.0)A Free:(14.0 13.0 14.0)A ALB:(14.1 13.0 14.0)A
2025-11-01T12:15:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T12:15:11.882Z:INFO:active_lb.c:308:SMt:(6.0 3.0 2.0)A Free:(10.0 13.0 14.0)A ALB:(11.2 13.0 14.0)A
2025-11-01T12:19:55.851Z:USER:taskMaster.c:6684:Socket #1: L1N=230.6V L2N=232.0V L3N=230.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T12:20:00.703Z:USER:taskMaster.c:6582:Temperature: 26.9 C
2025-11-01T12:25:11.816Z:INFO:active_lb.c:308:SMt:(6.0 3.0 2.0)A Free:(10.0 13.0 14.0)A ALB:(9.6 13.0 14.0)A
2025-11-01T12:30:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T12:34:55.757Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=236.3V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T12:35:01.105Z:USER:taskMaster.c:6582:Temperature: 26.8 C
2025-11-01T12:35:11.753Z:INFO:active_lb.c:308:SMt:(7.0 3.0 2.0)A Free:(9.0 13.0 14.0)A ALB:(9.0 12.9 14.0)A
2025-11-01T12:45:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T12:45:11.691Z:INFO:active_lb.c:308:SMt:(4.0 3.0 2.0)A Free:(12.0 13.0 14.0)A ALB:(12.0 12.8 14.0)A
2025-11-01T12:49:55.660Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.3V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T12:50:01.859Z:USER:taskMaster.c:6582:Temperature: 26.6 C
2025-11-01T12:55:11.628Z:INFO:active_lb.c:308:SMt:(2.0 3.0 2.0)A Free:(14.0 13.0 14.0)A ALB:(14.0 13.0 14.0)A
2025-11-01T13:00:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T13:04:55.566Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=234.3V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T13:05:01.964Z:USER:taskMaster.c:6582:Temperature: 26.6 C
2025-11-01T13:05:11.566Z:INFO:active_lb.c:308:SMt:(2.0 13.0 2.0)A Free:(14.0 3.0 14.0)A ALB:(14.0 3.2 14.0)A
2025-11-01T13:15:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T13:15:11.503Z:INFO:active_lb.c:308:SMt:(2.0 12.0 2.0)A Free:(14.0 4.0 14.0)A ALB:(14.0 5.9 14.0)A
2025-11-01T13:19:55.472Z:USER:taskMaster.c:6684:Socket #1: L1N=235.6V L2N=237.3V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T13:20:02.371Z:USER:taskMaster.c:6582:Temperature: 26.6 C
2025-11-01T13:25:11.437Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 12.7 14.0)A
2025-11-01T13:30:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T13:34:55.378Z:USER:taskMaster.c:6684:Socket #1: L1N=235.9V L2N=236.1V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T13:34:55.976Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-01T13:34:56.246Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-01T13:35:02.777Z:USER:taskMaster.c:6582:Temperature: 26.8 C
2025-11-01T13:35:03.226Z:INFO:heap_trace.c:493:free: 69304/160768 (43.1%) min: 37040 (23.0%) alloc #: 195
2025-11-01T13:35:03.234Z:INFO:heap_trace.c:495:fragm: 40.9% 4K: 17.3% free blocks: # 14 largest: 40992
2025-11-01T13:35:11.375Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.1 10.3 14.0)A
2025-11-01T13:45:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T13:45:11.312Z:INFO:active_lb.c:308:SMt:(1.0 3.0 5.0)A Free:(15.0 13.0 11.0)A ALB:(15.0 12.9 14.0)A
2025-11-01T13:49:55.281Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=232.1V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T13:50:02.730Z:USER:taskMaster.c:6582:Temperature: 26.9 C
2025-11-01T13:55:11.250Z:INFO:active_lb.c:308:SMt:(1.0 13.0 3.0)A Free:(15.0 3.0 13.0)A ALB:(15.0 12.5 13.4)A
2025-11-01T14:00:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T14:04:55.187Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=233.1V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T14:05:02.636Z:USER:taskMaster.c:6582:Temperature: 26.8 C
2025-11-01T14:05:11.187Z:INFO:active_lb.c:308:SMt:(3.0 3.0 3.0)A Free:(13.0 13.0 13.0)A ALB:(12.8 13.0 13.0)A
2025-11-01T14:15:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T14:15:11.121Z:INFO:active_lb.c:308:SMt:(2.0 3.0 2.0)A Free:(14.0 13.0 14.0)A ALB:(14.0 13.0 14.0)A
2025-11-01T14:19:55.093Z:USER:taskMaster.c:6684:Socket #1: L1N=230.5V L2N=231.1V L3N=230.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T14:20:03.093Z:USER:taskMaster.c:6582:Temperature: 26.8 C
2025-11-01T14:25:11.058Z:INFO:active_lb.c:308:SMt:(2.0 4.0 2.0)A Free:(14.0 12.0 14.0)A ALB:(14.0 12.1 14.0)A
2025-11-01T14:30:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T14:34:54.996Z:USER:taskMaster.c:6684:Socket #1: L1N=235.3V L2N=235.1V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T14:35:03.546Z:USER:taskMaster.c:6582:Temperature: 26.4 C
2025-11-01T14:35:10.996Z:INFO:active_lb.c:308:SMt:(-2.0 4.0 2.0)A Free:(18.0 12.0 14.0)A ALB:(17.8 12.6 14.0)A
2025-11-01T14:45:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T14:45:10.933Z:INFO:active_lb.c:308:SMt:(2.0 4.0 2.0)A Free:(14.0 12.0 14.0)A ALB:(14.2 12.0 14.0)A
2025-11-01T14:49:54.902Z:USER:taskMaster.c:6684:Socket #1: L1N=231.6V L2N=230.6V L3N=230.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T14:50:03.953Z:USER:taskMaster.c:6582:Temperature: 26.4 C
2025-11-01T14:55:10.871Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.0 13.4 14.0)A
2025-11-01T15:00:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T15:04:54.808Z:USER:taskMaster.c:6684:Socket #1: L1N=231.5V L2N=231.5V L3N=231.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T15:05:04.359Z:USER:taskMaster.c:6582:Temperature: 26.4 C
2025-11-01T15:05:10.804Z:INFO:active_lb.c:308:SMt:(-1.0 5.0 2.0)A Free:(17.0 11.0 14.0)A ALB:(16.3 11.0 14.0)A
2025-11-01T15:15:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T15:15:10.742Z:INFO:active_lb.c:308:SMt:(-1.0 3.0 2.0)A Free:(17.0 13.0 14.0)A ALB:(16.5 13.6 14.0)A
2025-11-01T15:19:54.714Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=235.2V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T15:20:04.812Z:USER:taskMaster.c:6582:Temperature: 26.1 C
2025-11-01T15:25:10.679Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-11-01T15:30:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T15:34:54.617Z:USER:taskMaster.c:6684:Socket #1: L1N=234.9V L2N=235.2V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T15:35:02.464Z:INFO:heap_trace.c:493:free: 69304/160768 (43.1%) min: 37040 (23.0%) alloc #: 195
2025-11-01T15:35:02.476Z:INFO:heap_trace.c:495:fragm: 40.9% 4K: 17.3% free blocks: # 14 largest: 40992
2025-11-01T15:35:05.218Z:USER:taskMaster.c:6582:Temperature: 26.1 C
2025-11-01T15:35:10.617Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-11-01T15:45:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T15:45:10.554Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(14.0 13.0 15.0)A ALB:(14.2 13.0 15.0)A
2025-11-01T15:49:54.523Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=233.6V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T15:50:05.621Z:USER:taskMaster.c:6582:Temperature: 25.8 C
2025-11-01T15:55:10.492Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(14.9 13.0 15.0)A
2025-11-01T16:00:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T16:04:54.480Z:USER:taskMaster.c:6684:Socket #1: L1N=233.2V L2N=234.2V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T16:05:06.078Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-01T16:05:10.425Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-11-01T16:15:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T16:15:10.363Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 12.9 14.0)A
2025-11-01T16:19:54.382Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=232.7V L3N=230.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T16:20:06.433Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-01T16:20:26.136Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-11-01T16:25:10.300Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(14.9 13.6 14.0)A
2025-11-01T16:30:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T16:30:26.070Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-11-01T16:34:54.289Z:USER:taskMaster.c:6684:Socket #1: L1N=231.6V L2N=232.5V L3N=231.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T16:35:06.839Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-01T16:35:10.238Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-01T16:40:26.109Z:INFO:taskLeds.c:338:Brightness set to 8%
2025-11-01T16:45:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T16:45:10.175Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-01T16:49:54.246Z:USER:taskMaster.c:6684:Socket #1: L1N=231.2V L2N=232.2V L3N=230.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T16:50:07.343Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-01T16:55:10.109Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-01T17:00:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T17:04:54.148Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=235.3V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T17:05:07.699Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-01T17:05:10.046Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 12.3 11.8)A
2025-11-01T17:15:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T17:15:09.984Z:INFO:active_lb.c:308:SMt:(1.0 4.0 2.0)A Free:(15.0 12.0 14.0)A ALB:(15.0 12.2 14.0)A
2025-11-01T17:19:54.054Z:USER:taskMaster.c:6684:Socket #1: L1N=231.9V L2N=232.1V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T17:20:08.253Z:USER:taskMaster.c:6582:Temperature: 25.0 C
2025-11-01T17:25:09.921Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-11-01T17:30:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T17:34:53.957Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=231.8V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T17:34:54.289Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-01T17:34:54.558Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-01T17:35:01.707Z:INFO:heap_trace.c:493:free: 69304/160768 (43.1%) min: 37040 (23.0%) alloc #: 195
2025-11-01T17:35:01.718Z:INFO:heap_trace.c:495:fragm: 40.9% 4K: 17.3% free blocks: # 14 largest: 40992
2025-11-01T17:35:08.757Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-01T17:35:09.855Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-11-01T17:45:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T17:45:09.792Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(14.6 14.0 15.0)A
2025-11-01T17:49:53.863Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=232.7V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T17:50:09.062Z:USER:taskMaster.c:6582:Temperature: 24.4 C
2025-11-01T17:55:09.730Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-01T18:00:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T18:04:53.769Z:USER:taskMaster.c:6684:Socket #1: L1N=236.0V L2N=234.7V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T18:05:09.468Z:USER:taskMaster.c:6582:Temperature: 24.4 C
2025-11-01T18:05:09.667Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 12.0 15.0)A
2025-11-01T18:15:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T18:15:09.605Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(14.8 12.4 14.9)A
2025-11-01T18:19:53.671Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=233.8V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T18:20:09.921Z:USER:taskMaster.c:6582:Temperature: 24.4 C
2025-11-01T18:25:09.539Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(14.4 13.6 15.0)A
2025-11-01T18:30:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T18:34:53.578Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=234.5V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T18:35:09.476Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(14.0 13.0 15.0)A ALB:(14.2 13.0 15.0)A
2025-11-01T18:35:10.375Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-01T18:45:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T18:45:09.414Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-01T18:49:53.484Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=233.5V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T18:50:10.781Z:USER:taskMaster.c:6582:Temperature: 24.0 C
2025-11-01T18:55:09.351Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 12.6 15.0)A
2025-11-01T19:00:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T19:04:53.386Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=234.5V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T19:05:09.285Z:INFO:active_lb.c:308:SMt:(2.0 4.0 1.0)A Free:(14.0 12.0 15.0)A ALB:(14.0 12.3 15.0)A
2025-11-01T19:05:11.238Z:USER:taskMaster.c:6582:Temperature: 23.9 C
2025-11-01T19:15:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T19:15:09.222Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 12.6 15.0)A
2025-11-01T19:19:53.292Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=232.7V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T19:20:11.140Z:USER:taskMaster.c:6582:Temperature: 23.8 C
2025-11-01T19:25:09.160Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.9)A
2025-11-01T19:30:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T19:34:53.199Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=234.4V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T19:35:00.945Z:INFO:heap_trace.c:493:free: 69304/160768 (43.1%) min: 37040 (23.0%) alloc #: 195
2025-11-01T19:35:00.957Z:INFO:heap_trace.c:495:fragm: 40.9% 4K: 17.3% free blocks: # 14 largest: 40992
2025-11-01T19:35:09.097Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-01T19:35:11.097Z:USER:taskMaster.c:6582:Temperature: 23.9 C
2025-11-01T19:45:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T19:45:09.031Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-01T19:49:53.101Z:USER:taskMaster.c:6684:Socket #1: L1N=236.0V L2N=235.4V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T19:50:11.500Z:USER:taskMaster.c:6582:Temperature: 23.8 C
2025-11-01T19:55:08.968Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 12.8 15.0)A
2025-11-01T19:56:24.882Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T19:56:25.210Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T19:56:25.503Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T19:56:25.675Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T19:56:26.136Z:SECURITY:web_functionalit:68:Changed '2059_00' from 1762026990066 => 1762026988829
2025-11-01T19:56:32.652Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x50)
2025-11-01T19:56:32.660Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T19:56:32.746Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T19:58:11.671Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-01T19:58:12.003Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T19:58:12.300Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-01T19:58:12.371Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-01T19:58:12.738Z:SECURITY:web_functionalit:68:Changed '2059_00' from 1762027093582 => 1762027093575
2025-11-01T19:58:33.597Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x0)
2025-11-01T19:58:33.605Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-01T19:58:33.691Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-01T20:00:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T20:04:55.105Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.0V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T20:05:11.003Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-01T20:05:13.953Z:USER:taskMaster.c:6582:Temperature: 23.5 C
2025-11-01T20:15:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T20:15:10.941Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-01T20:19:55.007Z:USER:taskMaster.c:6684:Socket #1: L1N=235.9V L2N=236.4V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T20:20:13.859Z:USER:taskMaster.c:6582:Temperature: 23.5 C
2025-11-01T20:25:10.875Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 12.0 15.0)A
2025-11-01T20:30:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T20:34:54.914Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=233.5V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T20:35:10.812Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-01T20:35:13.863Z:USER:taskMaster.c:6582:Temperature: 23.6 C
2025-11-01T20:45:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T20:45:10.750Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(14.0 13.0 15.0)A ALB:(14.0 13.0 15.0)A
2025-11-01T20:49:54.820Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=234.1V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T20:50:14.316Z:USER:taskMaster.c:6582:Temperature: 23.2 C
2025-11-01T20:55:10.687Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(14.9 11.4 15.0)A
2025-11-01T21:00:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T21:04:54.722Z:USER:taskMaster.c:6684:Socket #1: L1N=235.9V L2N=235.7V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T21:05:10.621Z:INFO:active_lb.c:308:SMt:(2.0 4.0 1.0)A Free:(14.0 12.0 15.0)A ALB:(14.4 12.0 15.0)A
2025-11-01T21:05:14.671Z:USER:taskMaster.c:6582:Temperature: 23.2 C
2025-11-01T21:15:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T21:15:10.558Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 12.0 15.0)A
2025-11-01T21:19:54.628Z:USER:taskMaster.c:6684:Socket #1: L1N=235.6V L2N=235.4V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T21:20:15.175Z:USER:taskMaster.c:6582:Temperature: 23.1 C
2025-11-01T21:25:10.496Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 12.0 15.0)A
2025-11-01T21:30:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T21:34:54.535Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=232.5V L3N=232.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T21:34:54.710Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-01T21:34:54.976Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-01T21:35:02.281Z:INFO:heap_trace.c:493:free: 69232/160768 (43.1%) min: 37040 (23.0%) alloc #: 197
2025-11-01T21:35:02.292Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.2% free blocks: # 16 largest: 40992
2025-11-01T21:35:10.429Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.2 15.0)A
2025-11-01T21:35:10.582Z:INFO:comFaults.c:482:Reset fault status
2025-11-01T21:35:15.632Z:USER:taskMaster.c:6582:Temperature: 23.1 C
2025-11-01T21:45:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T21:45:10.367Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(14.0 13.0 15.0)A ALB:(14.1 13.0 15.0)A
2025-11-01T21:49:54.437Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=232.1V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T21:50:16.085Z:USER:taskMaster.c:6582:Temperature: 23.0 C
2025-11-01T21:55:10.304Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-01T22:00:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T22:04:54.343Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=234.0V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T22:05:10.242Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.0 15.0 15.0)A
2025-11-01T22:05:16.488Z:USER:taskMaster.c:6582:Temperature: 23.0 C
2025-11-01T22:15:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T22:15:10.175Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.6 14.6 15.0)A
2025-11-01T22:19:54.246Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.2V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T22:20:16.945Z:USER:taskMaster.c:6582:Temperature: 22.9 C
2025-11-01T22:25:10.113Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 14.8 15.0)A
2025-11-01T22:30:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T22:34:54.152Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=234.6V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T22:35:10.050Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-01T22:35:17.398Z:USER:taskMaster.c:6582:Temperature: 23.0 C
2025-11-01T22:41:08.566Z:INFO:taskMain.c:5996:Socket #1: Active current 0.0->15.0 due to current limit: Active-LoadBalancing
2025-11-01T22:41:08.613Z:INFO:taskMaster.c:4957:Socket #1: state main : CABLE_CONNECTED
2025-11-01T22:41:08.621Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_A
2025-11-01T22:41:08.628Z:INFO:taskMaster.c:4979:Socket #1: state led : CABLE_CONNECTED
2025-11-01T22:41:08.816Z:INFO:taskMain.c:6494:Socket #1: CPhigh 12.4 V
2025-11-01T22:41:08.824Z:INFO:taskMain.c:6499:Socket #1: CPlow 12.4 V
2025-11-01T22:41:08.832Z:INFO:taskMain.c:6504:Socket #1: PP 698 Ohm (20 A)
2025-11-01T22:41:08.839Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.9% (14.9 A)
2025-11-01T22:41:09.648Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-01T22:41:09.656Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-01T22:41:09.664Z:INFO:taskMain.c:1419:Socket #1: main state: CABLE_CONNECTED, CP: 9.3/0.9, no tag
2025-11-01T22:41:10.660Z:INFO:taskMaster.c:4957:Socket #1: state main : EV_CONNECTED_UNAUTHORIZED
2025-11-01T22:41:10.671Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T22:41:11.648Z:INFO:taskMain.c:1419:Socket #1: main state: EV_CONNECTED_UNAUTHORIZED, CP: 9.3/0.9, no tag
2025-11-01T22:41:14.765Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-01T22:41:15.210Z:USER:tag.c:1623:Reader 0 Got NFC tag: 04BB29EAFD0F94
2025-11-01T22:41:15.410Z:USER:taskMaster.c:6931:Socket #1: has reliable metervalue
2025-11-01T22:41:15.417Z:INFO:taskMaster.c:1604:1 cables attached
2025-11-01T22:41:15.460Z:INFO:taskMaster.c:4979:Socket #1: state led : AUTHORISING
2025-11-01T22:41:15.472Z:USER:tag.c:584:Tag 04BB29EAFD0F94 is authorised by white list
2025-11-01T22:41:15.511Z:USER:taskMaster.c:1914:Multiple cables attached, prioritizing socket #1
2025-11-01T22:41:15.558Z:USER:board_ng9xx.c:5068:Socket #1: lock socket motor
2025-11-01T22:41:15.566Z:INFO:taskMaster.c:4957:Socket #1: state main : EV_CONNECTED_AUTHORIZED
2025-11-01T22:41:15.687Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-01T22:41:16.566Z:INFO:taskMain.c:1417:Socket #1: main state: EV_CONNECTED_AUTHORIZED, CP: 9.3/9.3, tag: 04BB29EAFD0F94
2025-11-01T22:41:16.578Z:INFO:taskMaster.c:7497:New charging session started, metervalue=5588146.000
2025-11-01T22:41:16.597Z:INFO:db_transaction.c:16:Added TransactionStart for socket 1 at 0x00001edb (ts: 2025-11-01 22:41:15)
2025-11-01T22:41:16.617Z:INFO:taskMaster.c:4979:Socket #1: state led : EV_CONNECTED
2025-11-01T22:41:16.628Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T22:41:16.656Z:INFO:taskMain.c:938:Socket #1: charging session status set active
2025-11-01T22:41:16.691Z:INFO:taskMaster.c:6353:Socket #1: external current limit 15.9 A until 2025-11-01T23:00:00Z
2025-11-01T22:41:16.703Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-01T22:41:16.714Z:INFO:db_chargingprofi:26: socket 0
2025-11-01T22:41:16.722Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-01T22:41:16.730Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-01T22:41:16.738Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-01T22:41:16.746Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-01T22:41:16.757Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-01T22:41:16.765Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-01T22:41:16.773Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-01T22:41:16.781Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-01T22:41:16.789Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-01T22:41:16.796Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-01T22:41:16.804Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-01T22:41:16.812Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-01T22:41:16.820Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-01T22:41:16.832Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-01T22:41:16.839Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-01T22:41:16.847Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-01T22:41:16.859Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-01T22:41:16.867Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-01T22:41:16.875Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-01T22:41:16.882Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-01T22:41:16.890Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-01T22:41:16.945Z:USER:taskMaster.c:6402:Socket #1: external current limit 15.9 A
2025-11-01T22:41:16.953Z:INFO:taskMaster.c:4957:Socket #1: state main : WAIT_FOR_START_METERVALUE
2025-11-01T22:41:16.964Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_PREPARING
2025-11-01T22:41:17.765Z:INFO:taskMain.c:1417:Socket #1: main state: WAIT_FOR_START_METERVALUE, CP: 9.3/9.3, tag: 04BB29EAFD0F
2025-11-01T22:41:17.765Z:INFO:taskMain.c:1417:94
2025-11-01T22:41:19.710Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T22:41:19.722Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T22:41:19.761Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T22:41:19.785Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T22:41:20.660Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-01T22:41:20.671Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-01T22:41:20.679Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=235.7V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T22:41:20.691Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T22:41:20.703Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-01T22:41:20.710Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-01T22:41:20.718Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T22:41:20.796Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-01T22:41:21.687Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T22:41:23.515Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->15.0 due to current limit: Active-LoadBalancing
2025-11-01T22:41:23.707Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.9% (14.9 A)
2025-11-01T22:41:26.808Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-01T22:41:28.515Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.9 due to current limit: ChargingProfile
2025-11-01T22:41:28.753Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-01T22:41:50.707Z:USER:taskMaster.c:6684:Socket #1: L1N=233.3V L2N=234.2V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T22:41:50.718Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-11-01T22:42:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T22:42:20.671Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-01T22:42:20.703Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=233.9V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T22:42:20.714Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-11-01T22:42:26.757Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->26.3)
2025-11-01T22:42:26.804Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-01T22:42:38.757Z:INFO:taskMain.c:5996:Socket #1: Active current 15.8->15.2 due to current limit: Active-LoadBalancing
2025-11-01T22:42:38.769Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.3->25.3)
2025-11-01T22:42:39.449Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.3% (15.2 A)
2025-11-01T22:42:50.699Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=233.5V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T22:42:50.714Z:USER:taskMaster.c:6720:Socket #1: I1=14.7A I2=14.7A I3=14.7A P=10.3kW Idc=0.7mA
2025-11-01T22:42:50.757Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->14.6 due to current limit: Active-LoadBalancing
2025-11-01T22:42:50.769Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->24.3)
2025-11-01T22:42:51.566Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-01T22:43:02.753Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T22:43:14.753Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-01T22:43:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T22:43:20.699Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=233.3V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T22:43:20.710Z:USER:taskMaster.c:6720:Socket #1: I1=14.7A I2=14.7A I3=14.7A P=10.3kW Idc=0.7mA
2025-11-01T22:43:26.753Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.9)
2025-11-01T22:43:38.750Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-01T22:43:38.765Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-01T22:43:50.695Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=233.6V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T22:43:50.707Z:USER:taskMaster.c:6720:Socket #1: I1=14.4A I2=14.4A I3=14.3A P=10.0kW Idc=0.7mA
2025-11-01T22:43:50.750Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T22:43:50.761Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-01T22:43:51.144Z:INFO:EVCapabilities.c:24:Socket #1 EV: #phases supported: 3
2025-11-01T22:44:02.750Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T22:44:14.750Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-01T22:44:14.761Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-01T22:44:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T22:44:16.093Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000002, address 0x00002000 (1)
2025-11-01T22:44:16.101Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-01T22:44:20.691Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=233.6V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T22:44:20.703Z:USER:taskMaster.c:6720:Socket #1: I1=14.2A I2=14.3A I3=14.2A P=9.9kW Idc=0.7mA
2025-11-01T22:44:26.746Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-01T22:44:26.757Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-01T22:44:38.746Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-01T22:44:38.757Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-01T22:44:50.687Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=233.5V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T22:44:50.699Z:USER:taskMaster.c:6720:Socket #1: I1=13.9A I2=13.9A I3=13.8A P=9.7kW Idc=0.7mA
2025-11-01T22:44:50.746Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-01T22:44:50.757Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-01T22:45:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T22:45:02.742Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-01T22:45:09.984Z:INFO:active_lb.c:308:SMt:(15.0 14.0 15.0)A Free:(1.0 2.0 1.0)A ALB:(14.4 15.4 14.9)A
2025-11-01T22:45:14.742Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-01T22:45:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T22:45:20.683Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=233.4V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T22:45:20.699Z:USER:taskMaster.c:6720:Socket #1: I1=14.2A I2=14.2A I3=14.2A P=9.9kW Idc=0.7mA
2025-11-01T22:45:26.742Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T22:45:38.738Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-01T22:45:38.753Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-01T22:45:47.281Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T22:45:47.292Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-01T22:45:47.300Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-01T22:45:47.308Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T22:45:47.316Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-01T22:45:48.308Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T22:45:50.683Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=235.3V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T22:45:50.695Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T22:45:50.738Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->8.8 due to current limit: Active-LoadBalancing
2025-11-01T22:45:51.335Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.6% (8.8 A)
2025-11-01T22:46:02.738Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->10.9 due to current limit: Active-LoadBalancing
2025-11-01T22:46:03.457Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.1% (10.9 A)
2025-11-01T22:46:14.734Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->12.1 due to current limit: Active-LoadBalancing
2025-11-01T22:46:15.574Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.2% (12.1 A)
2025-11-01T22:46:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T22:46:17.277Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-01T22:46:17.289Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-01T22:46:17.593Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-01T22:46:17.601Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-01T22:46:18.304Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-01T22:46:20.679Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=235.4V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T22:46:20.691Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T22:46:20.703Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-01T22:46:21.328Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-01T22:46:21.335Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-01T22:46:21.343Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-01T22:46:21.828Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-01T22:46:21.839Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-01T22:46:22.343Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-01T22:46:22.835Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-01T22:46:26.734Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.9 due to current limit: Active-LoadBalancing
2025-11-01T22:46:26.875Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.4% (12.8 A)
2025-11-01T22:46:38.734Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.7 due to current limit: Active-LoadBalancing
2025-11-01T22:46:38.992Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.8% (13.7 A)
2025-11-01T22:46:50.730Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->14.2 due to current limit: Active-LoadBalancing
2025-11-01T22:46:51.113Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.7% (14.2 A)
2025-11-01T22:47:02.730Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.3 due to current limit: Active-LoadBalancing
2025-11-01T22:47:14.730Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-01T22:47:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T22:47:38.726Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-01T22:48:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T22:49:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T22:50:02.710Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-01T22:50:02.992Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-01T22:50:14.710Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-01T22:50:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T22:50:17.304Z:USER:taskMaster.c:6582:Temperature: 23.8 C
2025-11-01T22:50:26.707Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T22:50:50.707Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-01T22:51:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T22:52:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T22:52:38.695Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-01T22:52:39.523Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-01T22:52:50.695Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T22:53:02.691Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-01T22:53:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T22:53:26.691Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-01T22:54:02.687Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-01T22:54:03.347Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-01T22:54:14.683Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-01T22:54:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T22:54:26.683Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-01T22:54:50.679Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-01T22:55:09.921Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-01T22:55:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T22:56:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T22:56:38.667Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-01T22:56:38.871Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-01T22:56:50.667Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T22:57:02.667Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-01T22:57:14.664Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-01T22:57:15.226Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-01T22:57:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T22:57:26.664Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-01T22:57:38.664Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-01T22:58:02.660Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-01T22:58:14.660Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.6 due to current limit: Active-LoadBalancing
2025-11-01T22:58:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T22:58:26.656Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T22:58:38.656Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-01T22:59:02.652Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-01T22:59:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:00:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T23:00:00.101Z:INFO:taskMaster.c:6353:Socket #1: external current limit 15.9 A until 2025-11-02T23:00:00Z
2025-11-01T23:00:00.117Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-01T23:00:00.125Z:INFO:db_chargingprofi:26: socket 0
2025-11-01T23:00:00.132Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-01T23:00:00.144Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-01T23:00:00.152Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-01T23:00:00.160Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-01T23:00:00.171Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-01T23:00:00.179Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-01T23:00:00.187Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-01T23:00:00.195Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-01T23:00:00.203Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-01T23:00:00.210Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-01T23:00:00.218Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-01T23:00:00.226Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-01T23:00:00.234Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-01T23:00:00.246Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-01T23:00:00.253Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-01T23:00:00.261Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-01T23:00:00.273Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-01T23:00:00.281Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-01T23:00:00.289Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-01T23:00:00.296Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-01T23:00:00.304Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-01T23:00:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:01:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:01:20.582Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=235.2V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T23:01:20.593Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T23:02:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:03:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:04:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:05:09.859Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-01T23:05:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:05:17.660Z:USER:taskMaster.c:6582:Temperature: 23.5 C
2025-11-01T23:06:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:07:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:08:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:09:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:10:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:11:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:12:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:13:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:14:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:15:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T23:15:02.601Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-01T23:15:02.683Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-01T23:15:09.796Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 14.4 15.0)A
2025-11-01T23:15:14.601Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-01T23:15:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:15:26.601Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T23:15:50.597Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-01T23:16:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:16:20.488Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=235.6V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T23:16:20.500Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T23:17:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:18:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:19:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:20:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:20:18.062Z:USER:taskMaster.c:6582:Temperature: 23.4 C
2025-11-01T23:21:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:22:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:23:14.550Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-01T23:23:15.511Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-01T23:23:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:23:26.550Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T23:23:50.546Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-01T23:24:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:24:26.542Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-01T23:24:27.210Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-01T23:24:38.542Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-11-01T23:24:50.539Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-01T23:25:09.730Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.9 15.0 15.0)A
2025-11-01T23:25:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:25:26.535Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.0 due to current limit: Active-LoadBalancing
2025-11-01T23:26:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:27:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:28:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:29:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:30:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T23:30:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:31:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:31:20.394Z:USER:taskMaster.c:6684:Socket #1: L1N=235.6V L2N=235.8V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T23:31:20.406Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T23:32:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:33:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:34:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:35:01.519Z:INFO:heap_trace.c:493:free: 69232/160768 (43.1%) min: 37040 (23.0%) alloc #: 197
2025-11-01T23:35:01.527Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.2% free blocks: # 16 largest: 40992
2025-11-01T23:35:09.667Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-01T23:35:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:35:18.417Z:USER:taskMaster.c:6582:Temperature: 23.2 C
2025-11-01T23:36:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:36:50.464Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-01T23:36:50.492Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-01T23:37:02.460Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-01T23:37:14.460Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-01T23:37:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:37:38.457Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-01T23:38:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:38:26.453Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-01T23:38:27.445Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-01T23:38:38.453Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-01T23:38:50.449Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-01T23:39:14.449Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-01T23:39:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:40:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:41:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:42:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:43:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:44:02.417Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->12.6 due to current limit: Active-LoadBalancing
2025-11-01T23:44:02.726Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-11-01T23:44:14.417Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->11.2 due to current limit: Active-LoadBalancing
2025-11-01T23:44:14.847Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.6% (11.2 A)
2025-11-01T23:44:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:44:26.414Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->10.3 due to current limit: Active-LoadBalancing
2025-11-01T23:44:26.964Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.1% (10.3 A)
2025-11-01T23:44:38.414Z:INFO:taskMain.c:5996:Socket #1: Active current 10.3->9.8 due to current limit: Active-LoadBalancing
2025-11-01T23:44:39.085Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.2% (9.7 A)
2025-11-01T23:44:50.414Z:INFO:taskMain.c:5996:Socket #1: Active current 9.8->9.5 due to current limit: Active-LoadBalancing
2025-11-01T23:45:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-01T23:45:02.410Z:INFO:taskMain.c:5996:Socket #1: Active current 9.5->9.3 due to current limit: Active-LoadBalancing
2025-11-01T23:45:09.605Z:INFO:active_lb.c:308:SMt:(7.0 1.0 1.0)A Free:(9.0 15.0 15.0)A ALB:(9.3 15.0 15.0)A
2025-11-01T23:45:14.410Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->9.2 due to current limit: Active-LoadBalancing
2025-11-01T23:45:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:45:16.804Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000003, address 0x00003000 (1)
2025-11-01T23:45:16.816Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-01T23:45:38.406Z:INFO:taskMain.c:5996:Socket #1: Active current 9.1->9.1 due to current limit: Active-LoadBalancing
2025-11-01T23:46:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:46:20.296Z:USER:taskMaster.c:6684:Socket #1: L1N=235.3V L2N=236.6V L3N=236.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-01T23:46:20.308Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-01T23:47:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:48:14.390Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.6 due to current limit: Active-LoadBalancing
2025-11-01T23:48:15.191Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.3% (8.6 A)
2025-11-01T23:48:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:48:26.390Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.4 due to current limit: Active-LoadBalancing
2025-11-01T23:48:38.390Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.2 due to current limit: Active-LoadBalancing
2025-11-01T23:49:02.386Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->8.1 due to current limit: Active-LoadBalancing
2025-11-01T23:49:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:50:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:50:18.820Z:USER:taskMaster.c:6582:Temperature: 23.2 C
2025-11-01T23:50:38.375Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->8.4 due to current limit: Active-LoadBalancing
2025-11-01T23:50:38.597Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.0% (8.4 A)
2025-11-01T23:50:50.375Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.6 due to current limit: Active-LoadBalancing
2025-11-01T23:51:02.375Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.8 due to current limit: Active-LoadBalancing
2025-11-01T23:51:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:51:26.371Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.9 due to current limit: Active-LoadBalancing
2025-11-01T23:52:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:53:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:53:26.359Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.6 due to current limit: Active-LoadBalancing
2025-11-01T23:53:27.250Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.3% (8.6 A)
2025-11-01T23:53:38.355Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.4 due to current limit: Active-LoadBalancing
2025-11-01T23:53:50.355Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.2 due to current limit: Active-LoadBalancing
2025-11-01T23:54:14.351Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->8.1 due to current limit: Active-LoadBalancing
2025-11-01T23:54:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:54:50.347Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->8.4 due to current limit: Active-LoadBalancing
2025-11-01T23:54:51.070Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.0% (8.4 A)
2025-11-01T23:55:02.347Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.7 due to current limit: Active-LoadBalancing
2025-11-01T23:55:09.542Z:INFO:active_lb.c:308:SMt:(7.0 2.0 1.0)A Free:(9.0 14.0 15.0)A ALB:(8.7 14.0 15.0)A
2025-11-01T23:55:14.347Z:INFO:taskMain.c:5996:Socket #1: Active current 8.7->8.8 due to current limit: Active-LoadBalancing
2025-11-01T23:55:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:55:38.343Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.9 due to current limit: Active-LoadBalancing
2025-11-01T23:56:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:57:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:58:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:58:50.324Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->11.4 due to current limit: Active-LoadBalancing
2025-11-01T23:58:50.414Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.9% (11.3 A)
2025-11-01T23:59:02.324Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->12.8 due to current limit: Active-LoadBalancing
2025-11-01T23:59:02.531Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.3% (12.8 A)
2025-11-01T23:59:14.320Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->13.7 due to current limit: Active-LoadBalancing
2025-11-01T23:59:14.652Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.8% (13.7 A)
2025-11-01T23:59:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-01T23:59:26.320Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->14.0 due to current limit: Active-LoadBalancing
2025-11-02T00:00:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T00:00:07.664Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-02T00:00:07.671Z:INFO:db_chargingprofi:26: socket 0
2025-11-02T00:00:07.679Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-02T00:00:07.687Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-02T00:00:07.695Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-02T00:00:07.707Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-02T00:00:07.714Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-02T00:00:07.726Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-02T00:00:07.734Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-02T00:00:07.742Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-02T00:00:07.750Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-02T00:00:07.757Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-02T00:00:07.765Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-02T00:00:07.773Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-02T00:00:07.781Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-02T00:00:07.792Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-02T00:00:07.800Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-02T00:00:07.808Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-02T00:00:07.816Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-02T00:00:07.824Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-02T00:00:07.832Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-02T00:00:07.839Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-02T00:00:07.851Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-02T00:00:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:01:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:01:20.203Z:USER:taskMaster.c:6684:Socket #1: L1N=236.4V L2N=236.9V L3N=236.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T00:01:20.214Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T00:02:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:03:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:04:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:05:09.476Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-02T00:05:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:05:19.179Z:USER:taskMaster.c:6582:Temperature: 23.2 C
2025-11-02T00:06:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:07:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:07:26.269Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->12.2 due to current limit: Active-LoadBalancing
2025-11-02T00:07:26.468Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.3% (12.2 A)
2025-11-02T00:07:38.269Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->10.1 due to current limit: Active-LoadBalancing
2025-11-02T00:07:38.589Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.8% (10.1 A)
2025-11-02T00:07:50.265Z:INFO:taskMain.c:5996:Socket #1: Active current 10.1->8.9 due to current limit: Active-LoadBalancing
2025-11-02T00:07:50.707Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.7% (8.8 A)
2025-11-02T00:08:02.265Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.1 due to current limit: Active-LoadBalancing
2025-11-02T00:08:02.824Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.5% (8.1 A)
2025-11-02T00:08:14.265Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->7.7 due to current limit: Active-LoadBalancing
2025-11-02T00:08:14.945Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.7% (7.6 A)
2025-11-02T00:08:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:08:26.261Z:INFO:taskMain.c:5996:Socket #1: Active current 7.7->7.8 due to current limit: Active-LoadBalancing
2025-11-02T00:08:50.261Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->7.9 due to current limit: Active-LoadBalancing
2025-11-02T00:09:14.257Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->8.4 due to current limit: Active-LoadBalancing
2025-11-02T00:09:14.527Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.9% (8.3 A)
2025-11-02T00:09:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:09:26.257Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.6 due to current limit: Active-LoadBalancing
2025-11-02T00:09:38.253Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.8 due to current limit: Active-LoadBalancing
2025-11-02T00:10:02.253Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.9 due to current limit: Active-LoadBalancing
2025-11-02T00:10:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:11:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:12:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:13:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:14:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:15:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T00:15:09.414Z:INFO:active_lb.c:308:SMt:(7.0 1.0 1.0)A Free:(9.0 15.0 15.0)A ALB:(9.0 15.0 15.0)A
2025-11-02T00:15:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:16:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:16:20.105Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=233.9V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T00:16:20.117Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T00:17:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:18:14.199Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.2 due to current limit: Active-LoadBalancing
2025-11-02T00:18:14.820Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.6% (8.2 A)
2025-11-02T00:18:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:18:26.199Z:INFO:taskMain.c:5996:Socket #1: Active current 8.2->7.3 due to current limit: Active-LoadBalancing
2025-11-02T00:18:26.937Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.2% (7.3 A)
2025-11-02T00:18:38.199Z:INFO:taskMain.c:5996:Socket #1: Active current 7.3->6.8 due to current limit: Active-LoadBalancing
2025-11-02T00:18:39.058Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.3% (6.8 A)
2025-11-02T00:18:50.195Z:INFO:taskMain.c:5996:Socket #1: Active current 6.8->6.5 due to current limit: Active-LoadBalancing
2025-11-02T00:18:51.175Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.7% (6.4 A)
2025-11-02T00:19:02.195Z:INFO:taskMain.c:5996:Socket #1: Active current 6.5->6.3 due to current limit: Active-LoadBalancing
2025-11-02T00:19:14.195Z:INFO:taskMain.c:5996:Socket #1: Active current 6.3->6.2 due to current limit: Active-LoadBalancing
2025-11-02T00:19:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:19:26.191Z:INFO:taskMain.c:5996:Socket #1: Active current 6.2->9.3 due to current limit: Active-LoadBalancing
2025-11-02T00:19:26.523Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.5% (9.3 A)
2025-11-02T00:19:38.191Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->11.2 due to current limit: Active-LoadBalancing
2025-11-02T00:19:38.640Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.6% (11.2 A)
2025-11-02T00:19:50.191Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->12.3 due to current limit: Active-LoadBalancing
2025-11-02T00:19:50.761Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.5% (12.3 A)
2025-11-02T00:20:02.187Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->13.0 due to current limit: Active-LoadBalancing
2025-11-02T00:20:02.878Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.6% (13.0 A)
2025-11-02T00:20:14.187Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.8 due to current limit: Active-LoadBalancing
2025-11-02T00:20:14.996Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.9% (13.7 A)
2025-11-02T00:20:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:20:19.582Z:USER:taskMaster.c:6582:Temperature: 23.4 C
2025-11-02T00:20:26.187Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->14.3 due to current limit: Active-LoadBalancing
2025-11-02T00:20:27.117Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.7% (14.2 A)
2025-11-02T00:20:38.183Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-02T00:20:50.183Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:21:02.183Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-02T00:21:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:21:26.179Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-02T00:22:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:23:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:23:38.167Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-02T00:23:38.996Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-02T00:23:50.164Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:24:02.164Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T00:24:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:24:26.160Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-02T00:25:09.351Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.0 15.0 15.0)A
2025-11-02T00:25:14.156Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:25:14.937Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-02T00:25:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:25:26.156Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-02T00:25:38.152Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-02T00:25:46.847Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-02T00:25:46.855Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-02T00:25:46.863Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=235.2V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T00:25:46.878Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T00:25:46.886Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-02T00:25:46.898Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-02T00:25:46.906Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-02T00:25:47.253Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-02T00:25:47.851Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-02T00:25:49.722Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-02T00:25:50.195Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-02T00:25:50.746Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-02T00:25:54.722Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-02T00:26:02.152Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.9 due to current limit: ChargingProfile
2025-11-02T00:26:02.195Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-02T00:26:03.000Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-02T00:26:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:26:16.894Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=233.4V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T00:26:16.906Z:USER:taskMaster.c:6720:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-11-02T00:26:46.835Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-02T00:26:46.890Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.4V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T00:26:46.902Z:USER:taskMaster.c:6720:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-11-02T00:26:50.144Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.5 due to current limit: Active-LoadBalancing
2025-11-02T00:26:50.160Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->25.8)
2025-11-02T00:26:50.191Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-02T00:26:50.464Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.8% (15.5 A)
2025-11-02T00:27:02.144Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.0 due to current limit: Active-LoadBalancing
2025-11-02T00:27:02.156Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.8->24.9)
2025-11-02T00:27:02.585Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.9% (14.9 A)
2025-11-02T00:27:14.144Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-02T00:27:14.156Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-02T00:27:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:27:16.886Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=233.7V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T00:27:16.898Z:USER:taskMaster.c:6720:Socket #1: I1=14.4A I2=14.4A I3=14.3A P=10.1kW Idc=0.7mA
2025-11-02T00:27:26.140Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-02T00:27:26.156Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-02T00:27:38.140Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-02T00:27:38.152Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-02T00:27:46.882Z:USER:taskMaster.c:6684:Socket #1: L1N=233.3V L2N=233.6V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T00:27:46.894Z:USER:taskMaster.c:6720:Socket #1: I1=14.0A I2=14.1A I3=14.0A P=9.8kW Idc=0.7mA
2025-11-02T00:27:50.140Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-02T00:27:50.152Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.9)
2025-11-02T00:28:02.136Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-02T00:28:02.152Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.6)
2025-11-02T00:28:14.136Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:28:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:28:16.882Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=233.7V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T00:28:16.894Z:USER:taskMaster.c:6720:Socket #1: I1=14.0A I2=14.0A I3=14.0A P=9.8kW Idc=0.7mA
2025-11-02T00:28:26.136Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:28:38.132Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-02T00:28:46.878Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.0V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T00:28:46.890Z:USER:taskMaster.c:6720:Socket #1: I1=14.4A I2=14.5A I3=14.3A P=10.1kW Idc=0.7mA
2025-11-02T00:28:50.132Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-02T00:28:50.144Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T00:29:02.132Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-02T00:29:14.128Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-02T00:29:14.144Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-02T00:29:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:29:16.875Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=234.0V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T00:29:16.886Z:USER:taskMaster.c:6720:Socket #1: I1=14.5A I2=14.6A I3=14.6A P=10.1kW Idc=0.7mA
2025-11-02T00:29:26.128Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:29:26.140Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T00:29:38.128Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T00:29:38.140Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T00:29:46.871Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=233.8V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T00:29:46.882Z:USER:taskMaster.c:6720:Socket #1: I1=14.2A I2=14.2A I3=14.2A P=9.9kW Idc=0.7mA
2025-11-02T00:29:50.125Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:29:50.140Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T00:30:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T00:30:02.125Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T00:30:02.136Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T00:30:14.125Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T00:30:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:30:16.867Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=233.8V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T00:30:16.878Z:USER:taskMaster.c:6720:Socket #1: I1=14.1A I2=14.2A I3=14.1A P=9.9kW Idc=0.7mA
2025-11-02T00:30:26.125Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-02T00:30:38.121Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-02T00:30:46.863Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.0V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T00:30:46.878Z:USER:taskMaster.c:6720:Socket #1: I1=14.6A I2=14.7A I3=14.5A P=10.3kW Idc=0.7mA
2025-11-02T00:30:46.886Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-02T00:30:50.121Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-02T00:30:50.132Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-02T00:31:02.121Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:31:02.132Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T00:31:14.117Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T00:31:14.128Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T00:31:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:31:26.117Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:31:26.128Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T00:31:38.117Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:31:50.113Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-02T00:32:02.113Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-02T00:32:14.113Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.1 due to current limit: Active-LoadBalancing
2025-11-02T00:32:14.125Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-02T00:32:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:32:26.109Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-02T00:32:26.125Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-02T00:32:38.109Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:32:38.121Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T00:32:50.109Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T00:32:50.121Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T00:33:02.105Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:33:02.121Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T00:33:14.105Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T00:33:14.117Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T00:33:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:33:26.105Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T00:33:38.101Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-02T00:33:50.101Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-02T00:34:02.101Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-02T00:34:14.097Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-02T00:34:14.113Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.2)
2025-11-02T00:34:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:34:26.097Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-02T00:34:26.109Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-02T00:34:38.097Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-02T00:34:38.109Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-02T00:34:50.093Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:34:50.109Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-02T00:35:02.093Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-02T00:35:02.105Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-02T00:35:09.289Z:INFO:active_lb.c:308:SMt:(16.0 16.0 15.0)A Free:(0.0 0.0 1.0)A ALB:(14.6 14.5 15.3)A
2025-11-02T00:35:14.093Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:35:14.105Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-02T00:35:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:35:19.984Z:USER:taskMaster.c:6582:Temperature: 24.8 C
2025-11-02T00:35:26.089Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T00:35:26.105Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.6)
2025-11-02T00:35:38.089Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:35:50.089Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:36:02.085Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-02T00:36:14.085Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-02T00:36:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:36:26.085Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-02T00:36:26.097Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-02T00:36:38.082Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-02T00:36:38.097Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-02T00:36:50.082Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:36:50.093Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-02T00:37:02.082Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-02T00:37:02.093Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-02T00:37:14.078Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:37:14.093Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-02T00:37:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:37:26.078Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-02T00:37:38.078Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-02T00:37:50.074Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-02T00:38:02.074Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-02T00:38:02.085Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-02T00:38:14.074Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:38:14.085Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T00:38:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:38:26.074Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T00:38:26.085Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T00:38:38.070Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:38:38.082Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T00:38:50.070Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T00:38:50.082Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T00:39:02.070Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T00:39:14.066Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-02T00:39:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:39:26.066Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-02T00:39:38.066Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-02T00:39:38.078Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-02T00:39:50.062Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:39:50.074Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T00:40:02.062Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T00:40:02.074Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T00:40:14.062Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:40:14.074Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T00:40:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:40:26.058Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:40:38.058Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-02T00:40:50.058Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.2 due to current limit: Active-LoadBalancing
2025-11-02T00:41:02.054Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-02T00:41:02.070Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->25.0)
2025-11-02T00:41:14.054Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-02T00:41:14.066Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.7)
2025-11-02T00:41:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:41:26.054Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:41:26.066Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-02T00:41:38.050Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T00:41:38.066Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-02T00:41:50.050Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:41:50.062Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->24.0)
2025-11-02T00:42:02.050Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T00:42:02.062Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T00:42:14.046Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T00:42:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:42:26.046Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-02T00:42:38.046Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-02T00:42:50.042Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-02T00:42:50.058Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-02T00:43:02.042Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:43:02.054Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T00:43:14.042Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T00:43:14.054Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-02T00:43:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:43:26.039Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:43:26.054Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->24.0)
2025-11-02T00:43:38.039Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:43:50.039Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-02T00:44:02.035Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.2 due to current limit: Active-LoadBalancing
2025-11-02T00:44:14.035Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-02T00:44:14.046Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->25.0)
2025-11-02T00:44:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:44:26.035Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-02T00:44:26.046Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.7)
2025-11-02T00:44:38.031Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:44:38.046Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-02T00:44:50.031Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T00:44:50.042Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-02T00:45:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T00:45:02.031Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:45:02.042Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->24.0)
2025-11-02T00:45:09.222Z:INFO:active_lb.c:308:SMt:(15.0 16.0 15.0)A Free:(1.0 0.0 1.0)A ALB:(14.8 14.4 15.3)A
2025-11-02T00:45:14.027Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T00:45:14.042Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T00:45:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:45:26.027Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T00:45:38.027Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:45:46.769Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.3V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T00:45:46.781Z:USER:taskMaster.c:6720:Socket #1: I1=14.3A I2=14.4A I3=14.3A P=10.0kW Idc=0.7mA
2025-11-02T00:45:50.027Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-02T00:46:02.023Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-02T00:46:14.023Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.1 due to current limit: Active-LoadBalancing
2025-11-02T00:46:14.035Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-02T00:46:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:46:16.316Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000004, address 0x00004000 (1)
2025-11-02T00:46:16.328Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-02T00:46:26.023Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-02T00:46:26.035Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-02T00:46:38.019Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:46:38.031Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T00:46:50.019Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T00:46:50.031Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T00:47:02.019Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:47:02.031Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T00:47:14.015Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T00:47:14.031Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T00:47:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:47:26.015Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T00:47:38.015Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-02T00:47:50.011Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-02T00:48:02.011Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-02T00:48:14.011Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-02T00:48:14.023Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.2)
2025-11-02T00:48:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:48:26.007Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-02T00:48:26.023Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->25.0)
2025-11-02T00:48:38.007Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-02T00:48:38.019Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.7)
2025-11-02T00:48:50.007Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:48:50.019Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-02T00:49:02.003Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T00:49:02.019Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T00:49:14.003Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:49:14.015Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T00:49:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:49:26.003Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T00:49:26.015Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T00:49:38.000Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-02T00:49:38.015Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-02T00:49:50.000Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.0 due to current limit: Active-LoadBalancing
2025-11-02T00:49:50.011Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.5->23.3)
2025-11-02T00:50:02.000Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.2 due to current limit: Active-LoadBalancing
2025-11-02T00:50:13.996Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-02T00:50:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:50:20.339Z:USER:taskMaster.c:6582:Temperature: 27.0 C
2025-11-02T00:50:25.996Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:50:37.996Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T00:50:38.007Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T00:50:49.992Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:50:50.007Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T00:51:01.992Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T00:51:02.003Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T00:51:13.992Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-02T00:51:14.003Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-02T00:51:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:51:25.988Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.0 due to current limit: Active-LoadBalancing
2025-11-02T00:51:26.003Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.5->23.3)
2025-11-02T00:51:37.988Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.2 due to current limit: Active-LoadBalancing
2025-11-02T00:51:49.988Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-02T00:52:01.984Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:52:13.984Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-02T00:52:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:52:25.984Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-02T00:52:25.996Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.7)
2025-11-02T00:52:37.984Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:52:37.996Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-02T00:52:49.980Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->11.8 due to current limit: Active-LoadBalancing
2025-11-02T00:52:49.992Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->19.5)
2025-11-02T00:52:50.761Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.5% (11.7 A)
2025-11-02T00:53:01.980Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->8.8 due to current limit: Active-LoadBalancing
2025-11-02T00:53:01.992Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->14.6)
2025-11-02T00:53:02.878Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.6% (8.8 A)
2025-11-02T00:53:13.980Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->7.1 due to current limit: Active-LoadBalancing
2025-11-02T00:53:13.992Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.6->11.7)
2025-11-02T00:53:14.003Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.7% (7.0 A)
2025-11-02T00:53:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:53:25.976Z:INFO:taskMain.c:5996:Socket #1: Active current 7.1->6.2 due to current limit: Active-LoadBalancing
2025-11-02T00:53:25.988Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.7->10.2)
2025-11-02T00:53:26.117Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.2% (6.1 A)
2025-11-02T00:53:37.976Z:INFO:taskMain.c:5996:Socket #1: Active current 6.2->6.5 due to current limit: Active-LoadBalancing
2025-11-02T00:53:38.234Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.8% (6.5 A)
2025-11-02T00:53:49.976Z:INFO:taskMain.c:5996:Socket #1: Active current 6.5->6.7 due to current limit: Active-LoadBalancing
2025-11-02T00:54:01.972Z:INFO:taskMain.c:5996:Socket #1: Active current 6.7->7.0 due to current limit: Active-LoadBalancing
2025-11-02T00:54:13.972Z:INFO:taskMain.c:5996:Socket #1: Active current 7.0->10.5 due to current limit: Active-LoadBalancing
2025-11-02T00:54:14.593Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.5% (10.5 A)
2025-11-02T00:54:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:54:25.972Z:INFO:taskMain.c:5996:Socket #1: Active current 10.5->14.0 due to current limit: Active-LoadBalancing
2025-11-02T00:54:26.710Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.2% (13.9 A)
2025-11-02T00:54:37.968Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->15.0 due to current limit: Active-LoadBalancing
2025-11-02T00:54:38.828Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.0% (15.0 A)
2025-11-02T00:54:49.968Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.6 due to current limit: Active-LoadBalancing
2025-11-02T00:54:50.949Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.0% (15.6 A)
2025-11-02T00:55:01.968Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.5 due to current limit: Active-LoadBalancing
2025-11-02T00:55:01.980Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.0->25.9)
2025-11-02T00:55:09.160Z:INFO:active_lb.c:308:SMt:(16.0 17.0 16.0)A Free:(0.0 -1.0 0.0)A ALB:(15.9 15.5 16.6)A
2025-11-02T00:55:13.964Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.0 due to current limit: Active-LoadBalancing
2025-11-02T00:55:13.980Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.9->25.0)
2025-11-02T00:55:14.175Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.0% (15.0 A)
2025-11-02T00:55:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:55:25.964Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.5 due to current limit: Active-LoadBalancing
2025-11-02T00:55:25.976Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.1)
2025-11-02T00:55:26.292Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-02T00:55:37.964Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-02T00:55:37.976Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-02T00:55:49.960Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-02T00:55:49.976Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-02T00:56:01.960Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:56:13.960Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T00:56:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:56:25.957Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-02T00:56:25.972Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-02T00:56:37.957Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:56:37.968Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-02T00:56:49.957Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T00:56:49.968Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.7)
2025-11-02T00:57:01.953Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.1 due to current limit: Active-LoadBalancing
2025-11-02T00:57:01.968Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.7->23.4)
2025-11-02T00:57:13.953Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.3 due to current limit: Active-LoadBalancing
2025-11-02T00:57:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:57:25.953Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T00:57:37.949Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:57:37.964Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-02T00:57:49.949Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T00:57:49.960Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.7)
2025-11-02T00:58:01.949Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.1 due to current limit: Active-LoadBalancing
2025-11-02T00:58:01.960Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.7->23.4)
2025-11-02T00:58:13.945Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.3 due to current limit: Active-LoadBalancing
2025-11-02T00:58:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:58:25.945Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T00:58:37.945Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T00:58:37.957Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-02T00:58:49.941Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T00:58:49.957Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.7)
2025-11-02T00:59:01.941Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.1 due to current limit: Active-LoadBalancing
2025-11-02T00:59:01.953Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.7->23.4)
2025-11-02T00:59:13.941Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.3 due to current limit: Active-LoadBalancing
2025-11-02T00:59:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T00:59:25.937Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T00:59:37.937Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-02T00:59:37.949Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-02T00:59:49.937Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-02T00:59:49.949Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-02T01:00:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T01:00:01.937Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:00:13.933Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:00:15.230Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-02T01:00:15.242Z:INFO:db_chargingprofi:26: socket 0
2025-11-02T01:00:15.250Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-02T01:00:15.257Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-02T01:00:15.265Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-02T01:00:15.273Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-02T01:00:15.285Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-02T01:00:15.292Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-02T01:00:15.300Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-02T01:00:15.308Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-02T01:00:15.316Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-02T01:00:15.324Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-02T01:00:15.332Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-02T01:00:15.339Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-02T01:00:15.347Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-02T01:00:15.359Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-02T01:00:15.367Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-02T01:00:15.375Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-02T01:00:15.386Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-02T01:00:15.394Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-02T01:00:15.402Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-02T01:00:15.410Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-02T01:00:15.417Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-02T01:00:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:00:25.933Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:00:25.945Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:00:37.933Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-02T01:00:37.945Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T01:00:46.675Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=232.8V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T01:00:46.687Z:USER:taskMaster.c:6720:Socket #1: I1=13.8A I2=13.8A I3=13.7A P=9.6kW Idc=0.7mA
2025-11-02T01:00:49.929Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-02T01:00:49.941Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-02T01:01:01.929Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:01:13.929Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:01:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:01:25.925Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:01:25.937Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:01:37.925Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->12.4 due to current limit: Active-LoadBalancing
2025-11-02T01:01:37.937Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->20.6)
2025-11-02T01:01:37.949Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-11-02T01:01:49.925Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->9.4 due to current limit: Active-LoadBalancing
2025-11-02T01:01:49.937Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.6->15.6)
2025-11-02T01:01:50.062Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.6% (9.4 A)
2025-11-02T01:02:01.921Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->7.2 due to current limit: Active-LoadBalancing
2025-11-02T01:02:01.933Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.6->12.0)
2025-11-02T01:02:02.183Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.0% (7.2 A)
2025-11-02T01:02:13.921Z:INFO:taskMain.c:5996:Socket #1: Active current 7.2->6.3 due to current limit: Active-LoadBalancing
2025-11-02T01:02:13.933Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (12.0->10.5)
2025-11-02T01:02:14.300Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.5% (6.3 A)
2025-11-02T01:02:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:02:25.921Z:INFO:taskMain.c:5996:Socket #1: Active current 6.3->6.2 due to current limit: Active-LoadBalancing
2025-11-02T01:02:25.933Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (10.5->10.3)
2025-11-02T01:02:37.917Z:INFO:taskMain.c:5996:Socket #1: Active current 6.2->6.5 due to current limit: Active-LoadBalancing
2025-11-02T01:02:49.917Z:INFO:taskMain.c:5996:Socket #1: Active current 6.5->6.8 due to current limit: Active-LoadBalancing
2025-11-02T01:03:01.917Z:INFO:taskMain.c:5996:Socket #1: Active current 6.8->7.0 due to current limit: Active-LoadBalancing
2025-11-02T01:03:13.914Z:INFO:taskMain.c:5996:Socket #1: Active current 7.0->7.2 due to current limit: Active-LoadBalancing
2025-11-02T01:03:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:03:25.914Z:INFO:taskMain.c:5996:Socket #1: Active current 7.2->7.1 due to current limit: Active-LoadBalancing
2025-11-02T01:03:25.925Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (12.0->11.8)
2025-11-02T01:03:37.914Z:INFO:taskMain.c:5996:Socket #1: Active current 7.1->6.5 due to current limit: Active-LoadBalancing
2025-11-02T01:03:37.925Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.8->10.8)
2025-11-02T01:03:38.121Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.8% (6.5 A)
2025-11-02T01:03:49.910Z:INFO:taskMain.c:5996:Socket #1: Active current 6.5->6.0 due to current limit: Active-LoadBalancing
2025-11-02T01:03:49.925Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (10.8->10.8)
2025-11-02T01:03:49.937Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.98) < minimum current(6.00)
2025-11-02T01:03:49.957Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-02T01:03:49.964Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-02T01:03:49.976Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-02T01:03:50.242Z:INFO:taskMain.c:6499:Socket #1: CPlow 6.3 V
2025-11-02T01:03:50.957Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-02T01:03:50.964Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-02T01:03:50.972Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-02T01:03:50.980Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.2/9.2, tag: 04BB
2025-11-02T01:03:50.980Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-02T01:03:51.000Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-02T01:04:01.910Z:INFO:taskMain.c:5996:Socket #1: Active current 6.0->3.6 due to current limit: Active-LoadBalancing
2025-11-02T01:04:13.910Z:INFO:taskMain.c:5996:Socket #1: Active current 3.6->4.6 due to current limit: Active-LoadBalancing
2025-11-02T01:04:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:04:25.906Z:INFO:taskMain.c:5996:Socket #1: Active current 4.6->5.1 due to current limit: Active-LoadBalancing
2025-11-02T01:04:37.906Z:INFO:taskMain.c:5996:Socket #1: Active current 5.1->5.5 due to current limit: Active-LoadBalancing
2025-11-02T01:04:49.906Z:INFO:taskMain.c:5996:Socket #1: Active current 5.5->5.7 due to current limit: Active-LoadBalancing
2025-11-02T01:05:01.902Z:INFO:taskMain.c:5996:Socket #1: Active current 5.7->6.2 due to current limit: Active-LoadBalancing
2025-11-02T01:05:01.949Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-02T01:05:01.957Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-02T01:05:01.964Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-02T01:05:02.664Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-02T01:05:02.949Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-02T01:05:02.957Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-02T01:05:02.964Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.8V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T01:05:02.976Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T01:05:02.988Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-02T01:05:02.996Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-02T01:05:03.007Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-02T01:05:03.671Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-02T01:05:03.964Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-02T01:05:09.097Z:INFO:active_lb.c:308:SMt:(9.0 2.0 1.0)A Free:(7.0 14.0 15.0)A ALB:(6.2 13.8 14.8)A
2025-11-02T01:05:13.902Z:INFO:taskMain.c:5996:Socket #1: Active current 6.2->8.9 due to current limit: Active-LoadBalancing
2025-11-02T01:05:14.062Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.8% (8.9 A)
2025-11-02T01:05:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:05:20.695Z:USER:taskMaster.c:6582:Temperature: 28.0 C
2025-11-02T01:05:25.902Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->9.2 due to current limit: Active-LoadBalancing
2025-11-02T01:05:32.996Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=233.0V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T01:05:33.007Z:USER:taskMaster.c:6720:Socket #1: I1=8.9A I2=8.8A I3=8.8A P=6.1kW Idc=0.7mA
2025-11-02T01:05:37.898Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->8.6 due to current limit: Active-LoadBalancing
2025-11-02T01:05:37.914Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.2->14.4)
2025-11-02T01:05:38.300Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.4% (8.6 A)
2025-11-02T01:05:49.898Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->7.7 due to current limit: Active-LoadBalancing
2025-11-02T01:05:49.910Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.4->12.8)
2025-11-02T01:05:50.417Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.8% (7.7 A)
2025-11-02T01:06:01.898Z:INFO:taskMain.c:5996:Socket #1: Active current 7.7->8.0 due to current limit: Active-LoadBalancing
2025-11-02T01:06:02.949Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-02T01:06:02.992Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=232.9V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T01:06:03.003Z:USER:taskMaster.c:6720:Socket #1: I1=7.3A I2=7.4A I3=7.3A P=5.1kW Idc=0.7mA
2025-11-02T01:06:13.894Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->11.0 due to current limit: Active-LoadBalancing
2025-11-02T01:06:14.656Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.3% (11.0 A)
2025-11-02T01:06:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:06:25.894Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->14.0 due to current limit: Active-LoadBalancing
2025-11-02T01:06:26.773Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.3% (14.0 A)
2025-11-02T01:06:32.988Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=232.3V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T01:06:33.000Z:USER:taskMaster.c:6720:Socket #1: I1=13.6A I2=13.6A I3=13.6A P=9.5kW Idc=0.7mA
2025-11-02T01:06:37.894Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->15.9 due to current limit: Active-LoadBalancing
2025-11-02T01:06:38.894Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.4% (15.8 A)
2025-11-02T01:06:49.937Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-02T01:07:01.890Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.7 due to current limit: Active-LoadBalancing
2025-11-02T01:07:01.902Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->26.2)
2025-11-02T01:07:01.933Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-02T01:07:02.984Z:USER:taskMaster.c:6684:Socket #1: L1N=231.8V L2N=231.8V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T01:07:02.996Z:USER:taskMaster.c:6720:Socket #1: I1=15.6A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-11-02T01:07:13.890Z:INFO:taskMain.c:5996:Socket #1: Active current 15.7->15.2 due to current limit: Active-LoadBalancing
2025-11-02T01:07:13.902Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.2->25.3)
2025-11-02T01:07:14.238Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.3% (15.2 A)
2025-11-02T01:07:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:07:25.890Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:07:25.902Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->24.4)
2025-11-02T01:07:26.359Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.4% (14.6 A)
2025-11-02T01:07:32.980Z:USER:taskMaster.c:6684:Socket #1: L1N=231.8V L2N=232.3V L3N=232.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T01:07:32.996Z:USER:taskMaster.c:6720:Socket #1: I1=14.2A I2=14.3A I3=14.2A P=9.9kW Idc=0.7mA
2025-11-02T01:07:37.886Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:07:37.898Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-02T01:07:49.886Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-02T01:07:49.898Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-02T01:08:01.886Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:08:02.980Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=232.4V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T01:08:02.992Z:USER:taskMaster.c:6720:Socket #1: I1=13.8A I2=13.9A I3=13.8A P=9.6kW Idc=0.7mA
2025-11-02T01:08:13.882Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:08:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:08:25.882Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-02T01:08:32.976Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=232.2V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T01:08:32.988Z:USER:taskMaster.c:6720:Socket #1: I1=14.7A I2=14.7A I3=14.7A P=10.2kW Idc=0.7mA
2025-11-02T01:08:37.882Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-02T01:08:37.894Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-02T01:08:49.878Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:08:49.894Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T01:09:01.878Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:09:01.890Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T01:09:02.972Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=232.0V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T01:09:02.984Z:USER:taskMaster.c:6720:Socket #1: I1=14.3A I2=14.4A I3=14.3A P=10.0kW Idc=0.7mA
2025-11-02T01:09:13.878Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:09:13.890Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:09:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:09:25.875Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-02T01:09:25.890Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T01:09:32.968Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=232.5V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T01:09:32.980Z:USER:taskMaster.c:6720:Socket #1: I1=13.9A I2=13.9A I3=13.8A P=9.6kW Idc=0.7mA
2025-11-02T01:09:37.875Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:09:49.875Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:10:01.871Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-02T01:10:02.964Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=232.0V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T01:10:02.976Z:USER:taskMaster.c:6720:Socket #1: I1=14.4A I2=14.4A I3=14.3A P=10.0kW Idc=0.7mA
2025-11-02T01:10:02.988Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-02T01:10:13.871Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-02T01:10:13.882Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-02T01:10:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:10:25.871Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:10:25.882Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T01:10:37.867Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:10:37.882Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T01:10:49.867Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:10:49.878Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:11:01.867Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:11:13.863Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-02T01:11:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:11:25.863Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:11:25.875Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-02T01:11:37.863Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:11:37.875Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-02T01:11:49.859Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:11:49.875Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-02T01:12:01.859Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:12:01.871Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-02T01:12:13.859Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:12:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:12:25.855Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-02T01:12:37.855Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:12:37.867Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-02T01:12:49.855Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:12:49.867Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T01:13:01.851Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:13:01.867Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:13:13.851Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:13:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:13:25.851Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-02T01:13:37.847Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:13:37.863Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-02T01:13:49.847Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:13:49.859Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-02T01:14:01.847Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:14:01.859Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-02T01:14:13.847Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:14:13.859Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.9)
2025-11-02T01:14:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:14:25.843Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:14:37.843Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:14:49.843Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:14:49.855Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-02T01:15:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T01:15:01.839Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:15:01.851Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-02T01:15:09.035Z:INFO:active_lb.c:308:SMt:(15.0 16.0 15.0)A Free:(1.0 0.0 1.0)A ALB:(15.8 14.5 15.2)A
2025-11-02T01:15:13.839Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:15:13.851Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-02T01:15:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:15:25.839Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:15:37.835Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:15:49.835Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-02T01:16:01.835Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-02T01:16:01.847Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-02T01:16:13.832Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:16:13.847Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T01:16:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:16:25.832Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:16:25.843Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T01:16:37.832Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:16:37.843Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:16:49.828Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:17:01.828Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-02T01:17:13.828Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:17:13.839Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.6)
2025-11-02T01:17:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:17:25.824Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:17:25.839Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-02T01:17:37.824Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:17:37.835Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:17:49.824Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:18:01.820Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-02T01:18:13.820Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:18:13.832Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-02T01:18:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:18:25.820Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:18:25.832Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-02T01:18:37.816Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:18:37.832Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:18:49.816Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:19:01.816Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-02T01:19:13.812Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:19:13.828Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-02T01:19:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:19:25.812Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:19:25.824Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-02T01:19:37.812Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:19:37.824Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-02T01:19:49.808Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:19:49.824Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-02T01:20:01.808Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:20:13.808Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:20:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:20:21.050Z:USER:taskMaster.c:6582:Temperature: 28.6 C
2025-11-02T01:20:25.804Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-02T01:20:37.804Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-02T01:20:37.816Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-02T01:20:49.804Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:20:49.816Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-02T01:21:01.800Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:21:01.816Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-02T01:21:13.800Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:21:13.812Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:21:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:21:25.800Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:21:37.800Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-02T01:21:49.796Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:21:49.808Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T01:22:01.796Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:22:01.808Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-02T01:22:13.796Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:22:13.808Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-02T01:22:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:22:25.792Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:22:37.792Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:22:49.792Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-02T01:23:01.789Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-02T01:23:01.804Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.7)
2025-11-02T01:23:13.789Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:23:13.800Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-02T01:23:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:23:25.789Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:23:25.800Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T01:23:37.785Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:23:37.800Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:23:49.785Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:24:01.785Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-02T01:24:13.781Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:24:13.796Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-02T01:24:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:24:25.781Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:24:25.792Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-02T01:24:37.781Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:24:37.792Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-02T01:24:49.777Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:24:49.792Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->24.0)
2025-11-02T01:25:01.777Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:25:02.871Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=232.4V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T01:25:02.882Z:USER:taskMaster.c:6720:Socket #1: I1=14.1A I2=14.1A I3=14.1A P=9.8kW Idc=0.7mA
2025-11-02T01:25:08.968Z:INFO:active_lb.c:308:SMt:(14.0 15.0 15.0)A Free:(2.0 1.0 1.0)A ALB:(15.6 14.7 15.2)A
2025-11-02T01:25:13.777Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-02T01:25:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:25:25.773Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:25:25.789Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.6)
2025-11-02T01:25:37.773Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:25:37.785Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-02T01:25:49.773Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:25:49.785Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:26:01.769Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:26:13.769Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-02T01:26:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:26:25.769Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:26:25.781Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-02T01:26:37.765Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:26:37.781Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-02T01:26:49.765Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:26:49.777Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:27:01.765Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:27:13.761Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-02T01:27:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:27:25.761Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:27:25.773Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-02T01:27:37.761Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:27:37.773Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-02T01:27:49.757Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:27:49.773Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-02T01:28:01.757Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:28:01.769Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->24.0)
2025-11-02T01:28:13.757Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:28:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:28:25.753Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-02T01:28:37.753Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:28:37.765Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.6)
2025-11-02T01:28:49.753Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:28:49.765Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-02T01:29:01.750Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:29:01.765Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:29:13.750Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:29:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:29:25.750Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-02T01:29:37.750Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:29:37.761Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-02T01:29:49.746Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:29:49.757Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-02T01:30:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T01:30:01.746Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:30:01.757Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.1)
2025-11-02T01:30:13.746Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:30:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:30:25.742Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-02T01:30:37.742Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:30:37.753Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-02T01:30:49.742Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:30:49.753Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-02T01:31:01.738Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:31:01.753Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-02T01:31:13.738Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:31:13.750Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->24.0)
2025-11-02T01:31:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:31:25.738Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:31:37.734Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-02T01:31:49.734Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:31:49.746Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.6)
2025-11-02T01:32:01.734Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:32:01.746Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-02T01:32:13.730Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:32:13.746Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:32:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:32:25.730Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-02T01:32:25.742Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T01:32:37.730Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:32:49.726Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:33:01.726Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:33:01.738Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-02T01:33:13.726Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:33:13.738Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.1)
2025-11-02T01:33:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:33:25.722Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:33:37.722Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-02T01:33:49.722Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:33:49.734Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-02T01:34:01.718Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:34:01.734Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-02T01:34:13.718Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:34:13.730Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-02T01:34:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:34:25.718Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:34:25.730Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->24.0)
2025-11-02T01:34:37.714Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T01:34:37.730Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.7)
2025-11-02T01:34:49.714Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:34:54.039Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-02T01:34:54.308Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-02T01:35:00.757Z:INFO:heap_trace.c:493:free: 69232/160768 (43.1%) min: 37040 (23.0%) alloc #: 197
2025-11-02T01:35:00.769Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.2% free blocks: # 16 largest: 40992
2025-11-02T01:35:01.714Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:35:08.906Z:INFO:active_lb.c:308:SMt:(14.0 15.0 14.0)A Free:(2.0 1.0 2.0)A ALB:(15.8 14.7 15.4)A
2025-11-02T01:35:13.710Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-02T01:35:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:35:21.457Z:USER:taskMaster.c:6582:Temperature: 29.9 C
2025-11-02T01:35:25.710Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:35:25.722Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-02T01:35:37.710Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:35:37.722Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-02T01:35:49.707Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:35:49.722Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-02T01:36:01.707Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:36:01.718Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->24.0)
2025-11-02T01:36:13.707Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T01:36:13.718Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.7)
2025-11-02T01:36:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:36:25.703Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:36:37.703Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:36:49.703Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-02T01:37:01.703Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-02T01:37:13.699Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-02T01:37:13.710Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-02T01:37:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:37:25.699Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-02T01:37:25.710Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-02T01:37:37.699Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:37:37.710Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T01:37:49.695Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:37:49.707Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T01:38:01.695Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:38:01.707Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:38:13.695Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:38:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:38:25.691Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-02T01:38:37.691Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:38:37.703Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.6)
2025-11-02T01:38:49.691Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:38:49.703Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-02T01:39:01.687Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:39:01.703Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:39:13.687Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-02T01:39:13.699Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T01:39:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:39:25.687Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:39:37.683Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:39:49.683Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-02T01:40:01.683Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-02T01:40:01.695Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-02T01:40:02.777Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=232.4V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T01:40:02.789Z:USER:taskMaster.c:6720:Socket #1: I1=14.7A I2=14.7A I3=14.7A P=10.3kW Idc=0.7mA
2025-11-02T01:40:13.679Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:40:13.695Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T01:40:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:40:25.679Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:40:25.691Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T01:40:37.679Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:40:37.691Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:40:49.675Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-02T01:40:49.691Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T01:41:01.675Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:41:13.675Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:41:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:41:25.671Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-02T01:41:37.671Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-02T01:41:37.683Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-02T01:41:49.671Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:41:49.683Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T01:42:01.667Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:42:01.683Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T01:42:13.667Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:42:13.679Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:42:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:42:25.667Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:42:37.664Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-02T01:42:49.664Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:42:49.675Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-02T01:43:01.664Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:43:01.675Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-02T01:43:13.660Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:43:13.675Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-02T01:43:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:43:25.660Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-02T01:43:25.671Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.9)
2025-11-02T01:43:37.660Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:43:49.656Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:44:01.656Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-02T01:44:13.656Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-02T01:44:13.667Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-02T01:44:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:44:25.652Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:44:25.667Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T01:44:37.652Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:44:37.664Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T01:44:49.652Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:44:49.664Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:45:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T01:45:01.652Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-02T01:45:01.664Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T01:45:08.843Z:INFO:active_lb.c:308:SMt:(14.0 16.0 15.0)A Free:(2.0 0.0 1.0)A ALB:(14.7 14.3 15.2)A
2025-11-02T01:45:13.648Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-02T01:45:13.660Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-02T01:45:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:45:25.648Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.0 due to current limit: Active-LoadBalancing
2025-11-02T01:45:25.660Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.5->23.3)
2025-11-02T01:45:37.648Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.2 due to current limit: Active-LoadBalancing
2025-11-02T01:45:49.644Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:46:01.644Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:46:13.644Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:46:13.656Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T01:46:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:46:25.640Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:46:25.656Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:46:37.640Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-02T01:46:37.652Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T01:46:49.640Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-02T01:46:49.652Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-02T01:47:01.636Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.0 due to current limit: Active-LoadBalancing
2025-11-02T01:47:01.652Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.5->23.3)
2025-11-02T01:47:13.636Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.2 due to current limit: Active-LoadBalancing
2025-11-02T01:47:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:47:16.980Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000005, address 0x00005000 (1)
2025-11-02T01:47:16.992Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-02T01:47:25.636Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:47:37.632Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-02T01:47:37.648Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.9)
2025-11-02T01:47:49.632Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-02T01:47:49.644Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.6)
2025-11-02T01:48:01.632Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.0 due to current limit: Active-LoadBalancing
2025-11-02T01:48:01.644Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.6->23.3)
2025-11-02T01:48:13.628Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.3 due to current limit: Active-LoadBalancing
2025-11-02T01:48:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:48:25.628Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:48:37.628Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:48:37.640Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-02T01:48:49.625Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T01:48:49.640Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.7)
2025-11-02T01:49:01.625Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.1 due to current limit: Active-LoadBalancing
2025-11-02T01:49:01.636Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.7->23.5)
2025-11-02T01:49:13.625Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.0 due to current limit: Active-LoadBalancing
2025-11-02T01:49:13.636Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.5->23.2)
2025-11-02T01:49:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:49:25.621Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.2 due to current limit: Active-LoadBalancing
2025-11-02T01:49:37.621Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:49:49.621Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:50:01.617Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-02T01:50:13.617Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:50:13.628Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-02T01:50:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:50:21.859Z:USER:taskMaster.c:6582:Temperature: 30.4 C
2025-11-02T01:50:25.617Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:50:25.628Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-02T01:50:37.613Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:50:37.628Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T01:50:49.613Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:50:49.625Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:51:01.613Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T01:51:01.625Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T01:51:13.609Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-02T01:51:13.625Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-02T01:51:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:51:25.609Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.0 due to current limit: Active-LoadBalancing
2025-11-02T01:51:25.621Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.5->23.3)
2025-11-02T01:51:37.609Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.2 due to current limit: Active-LoadBalancing
2025-11-02T01:51:49.605Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:52:01.605Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:52:13.605Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:52:13.617Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T01:52:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:52:25.601Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:52:25.617Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:52:37.601Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T01:52:37.613Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T01:52:49.601Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-02T01:52:49.613Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-02T01:53:01.601Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.0 due to current limit: Active-LoadBalancing
2025-11-02T01:53:01.613Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.5->23.3)
2025-11-02T01:53:13.597Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.8 due to current limit: Active-LoadBalancing
2025-11-02T01:53:13.609Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.3->23.0)
2025-11-02T01:53:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:53:25.597Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->14.1 due to current limit: Active-LoadBalancing
2025-11-02T01:53:37.597Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.3 due to current limit: Active-LoadBalancing
2025-11-02T01:53:49.593Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:54:01.593Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:54:13.593Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:54:13.605Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-02T01:54:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:54:25.589Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:54:25.601Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T01:54:37.589Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:54:37.601Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:54:49.589Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T01:54:49.601Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T01:55:01.585Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-02T01:55:01.601Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-02T01:55:02.679Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=232.2V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T01:55:02.691Z:USER:taskMaster.c:6720:Socket #1: I1=13.9A I2=13.9A I3=13.9A P=9.7kW Idc=0.7mA
2025-11-02T01:55:08.781Z:INFO:active_lb.c:308:SMt:(16.0 16.0 15.0)A Free:(0.0 0.0 1.0)A ALB:(14.2 14.1 15.1)A
2025-11-02T01:55:13.585Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.0 due to current limit: Active-LoadBalancing
2025-11-02T01:55:13.597Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.5->23.3)
2025-11-02T01:55:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:55:25.585Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.2 due to current limit: Active-LoadBalancing
2025-11-02T01:55:37.582Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:55:49.582Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:55:49.593Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.9)
2025-11-02T01:56:01.582Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T01:56:01.593Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.6)
2025-11-02T01:56:13.578Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.1 due to current limit: Active-LoadBalancing
2025-11-02T01:56:13.593Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.6->23.4)
2025-11-02T01:56:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:56:25.578Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.3 due to current limit: Active-LoadBalancing
2025-11-02T01:56:37.578Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:56:49.574Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-02T01:57:01.574Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-02T01:57:13.574Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-02T01:57:13.585Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-02T01:57:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:57:25.570Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T01:57:25.585Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T01:57:37.570Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:57:37.582Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T01:57:49.570Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:57:49.582Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T01:58:01.566Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T01:58:01.582Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T01:58:13.566Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-02T01:58:13.578Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-02T01:58:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:58:25.566Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-02T01:58:37.562Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-02T01:58:49.562Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-02T01:58:49.574Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.1)
2025-11-02T01:59:01.562Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-02T01:59:01.574Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-02T01:59:13.558Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-02T01:59:13.574Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-02T01:59:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T01:59:25.558Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.0 due to current limit: Active-LoadBalancing
2025-11-02T01:59:25.570Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.5->23.3)
2025-11-02T01:59:37.558Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.2 due to current limit: Active-LoadBalancing
2025-11-02T01:59:49.554Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-02T02:00:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T02:00:01.554Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-02T02:00:13.554Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-02T02:00:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:00:19.546Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-02T02:00:19.558Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-02T02:00:19.566Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-02T02:00:19.574Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-02T02:00:20.472Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-02T02:00:20.542Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.2/-11.4, tag: 04BB29EAFD0F94
2025-11-02T02:00:22.750Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-02T02:00:22.757Z:INFO:db_chargingprofi:26: socket 0
2025-11-02T02:00:22.765Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-02T02:00:22.777Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-02T02:00:22.785Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-02T02:00:22.792Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-02T02:00:22.804Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-02T02:00:22.812Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-02T02:00:22.820Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-02T02:00:22.828Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-02T02:00:22.835Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-02T02:00:22.843Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-02T02:00:22.851Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-02T02:00:22.859Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-02T02:00:22.867Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-02T02:00:22.878Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-02T02:00:22.886Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-02T02:00:22.894Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-02T02:00:22.906Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-02T02:00:22.914Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-02T02:00:22.921Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-02T02:00:22.929Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-02T02:00:22.937Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-02T02:00:25.550Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->9.0 due to current limit: Active-LoadBalancing
2025-11-02T02:00:25.593Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.9% (8.9 A)
2025-11-02T02:00:37.550Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->5.4 due to current limit: Active-LoadBalancing
2025-11-02T02:00:37.562Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.39) < minimum current(6.00)
2025-11-02T02:00:37.593Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-02T02:00:37.605Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-02T02:00:37.613Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-02T02:00:37.710Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-02T02:00:38.589Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-11-02T02:00:38.589Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-02T02:00:49.550Z:INFO:taskMain.c:5996:Socket #1: Active current 5.4->8.8 due to current limit: Active-LoadBalancing
2025-11-02T02:00:49.593Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-02T02:00:49.605Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-02T02:00:49.613Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-02T02:00:49.699Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-02T02:00:50.601Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-02T02:01:01.546Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->10.9 due to current limit: Active-LoadBalancing
2025-11-02T02:01:01.707Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.1% (10.9 A)
2025-11-02T02:01:13.546Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->12.1 due to current limit: Active-LoadBalancing
2025-11-02T02:01:13.828Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.2% (12.1 A)
2025-11-02T02:01:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:01:19.640Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-02T02:01:19.648Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-02T02:01:19.886Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-02T02:01:19.894Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-02T02:01:20.636Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-02T02:01:23.640Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-02T02:01:23.667Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-02T02:01:23.675Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-02T02:01:24.140Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-02T02:01:24.148Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-02T02:01:24.675Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-02T02:01:25.167Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-02T02:01:25.546Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.9 due to current limit: Active-LoadBalancing
2025-11-02T02:01:26.175Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.4% (12.8 A)
2025-11-02T02:01:37.546Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.3 due to current limit: Active-LoadBalancing
2025-11-02T02:01:38.292Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.2% (13.3 A)
2025-11-02T02:01:49.542Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.6 due to current limit: Active-LoadBalancing
2025-11-02T02:02:01.542Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-02T02:02:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:02:25.539Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->14.3 due to current limit: Active-LoadBalancing
2025-11-02T02:02:25.761Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.8% (14.3 A)
2025-11-02T02:02:31.234Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-02T02:02:31.242Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-02T02:02:31.250Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=234.0V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:02:31.265Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T02:02:31.273Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-02T02:02:31.285Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-02T02:02:31.292Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-02T02:02:31.820Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-02T02:02:32.238Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-02T02:02:37.539Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->15.9 due to current limit: ChargingProfile
2025-11-02T02:02:37.582Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-02T02:02:38.296Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-02T02:03:01.281Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=231.9V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:03:01.292Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-11-02T02:03:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:03:31.222Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-02T02:03:31.277Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=232.2V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:03:31.289Z:USER:taskMaster.c:6720:Socket #1: I1=15.6A I2=15.6A I3=15.5A P=10.8kW Idc=0.7mA
2025-11-02T02:03:49.531Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.5 due to current limit: Active-LoadBalancing
2025-11-02T02:03:49.542Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->25.7)
2025-11-02T02:03:49.574Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-02T02:03:50.000Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.7% (15.4 A)
2025-11-02T02:04:01.273Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=232.0V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:04:01.285Z:USER:taskMaster.c:6720:Socket #1: I1=15.0A I2=15.1A I3=15.0A P=10.5kW Idc=0.7mA
2025-11-02T02:04:01.531Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->14.9 due to current limit: Active-LoadBalancing
2025-11-02T02:04:01.542Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->24.8)
2025-11-02T02:04:02.121Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.8% (14.9 A)
2025-11-02T02:04:13.527Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:04:13.542Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->23.9)
2025-11-02T02:04:14.238Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.9% (14.3 A)
2025-11-02T02:04:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:04:25.527Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T02:04:25.539Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.6)
2025-11-02T02:04:31.269Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=232.2V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:04:31.281Z:USER:taskMaster.c:6720:Socket #1: I1=13.8A I2=13.8A I3=13.7A P=9.6kW Idc=0.7mA
2025-11-02T02:04:37.527Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:04:49.523Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T02:05:01.265Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=232.3V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:05:01.281Z:USER:taskMaster.c:6720:Socket #1: I1=14.3A I2=14.3A I3=14.3A P=10.0kW Idc=0.7mA
2025-11-02T02:05:01.523Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-02T02:05:08.714Z:INFO:active_lb.c:308:SMt:(14.0 15.0 15.0)A Free:(2.0 1.0 1.0)A ALB:(15.9 14.9 15.8)A
2025-11-02T02:05:13.523Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.2 due to current limit: Active-LoadBalancing
2025-11-02T02:05:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:05:22.214Z:USER:taskMaster.c:6582:Temperature: 30.4 C
2025-11-02T02:05:25.519Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-02T02:05:25.535Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->25.0)
2025-11-02T02:05:31.265Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=232.1V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:05:31.277Z:USER:taskMaster.c:6720:Socket #1: I1=14.7A I2=14.7A I3=14.6A P=10.2kW Idc=0.7mA
2025-11-02T02:05:37.519Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-02T02:05:37.531Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-02T02:05:49.519Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T02:05:49.531Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T02:06:01.261Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=232.0V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:06:01.273Z:USER:taskMaster.c:6720:Socket #1: I1=14.3A I2=14.4A I3=14.3A P=10.0kW Idc=0.7mA
2025-11-02T02:06:01.515Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T02:06:01.531Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T02:06:13.515Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:06:13.527Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T02:06:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:06:25.515Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T02:06:25.527Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T02:06:31.257Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=231.9V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:06:31.269Z:USER:taskMaster.c:6720:Socket #1: I1=13.8A I2=13.9A I3=13.9A P=9.6kW Idc=0.7mA
2025-11-02T02:06:37.511Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T02:06:49.511Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-02T02:07:01.253Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=231.8V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:07:01.265Z:USER:taskMaster.c:6720:Socket #1: I1=14.3A I2=14.4A I3=14.3A P=10.0kW Idc=0.7mA
2025-11-02T02:07:01.511Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-02T02:07:13.507Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-02T02:07:13.523Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-02T02:07:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:07:25.507Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T02:07:25.519Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T02:07:31.250Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=231.7V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:07:31.265Z:USER:taskMaster.c:6720:Socket #1: I1=14.3A I2=14.4A I3=14.3A P=10.0kW Idc=0.7mA
2025-11-02T02:07:31.273Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-02T02:07:37.507Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T02:07:37.519Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T02:07:49.503Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:07:49.519Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T02:08:01.503Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T02:08:01.515Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T02:08:13.503Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-02T02:08:13.515Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-02T02:08:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:08:25.500Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:08:37.500Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T02:08:49.500Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-02T02:09:01.496Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.2 due to current limit: Active-LoadBalancing
2025-11-02T02:09:13.496Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-02T02:09:13.507Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->25.0)
2025-11-02T02:09:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:09:25.496Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-02T02:09:25.507Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-02T02:09:37.496Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T02:09:37.507Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T02:09:49.492Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T02:09:49.503Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T02:10:01.492Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:10:01.503Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T02:10:13.492Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T02:10:13.503Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T02:10:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:10:25.488Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-02T02:10:25.500Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-02T02:10:37.488Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:10:49.488Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-02T02:11:01.484Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-02T02:11:13.484Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-02T02:11:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:11:25.484Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-02T02:11:25.496Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-02T02:11:37.480Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-02T02:11:37.496Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-02T02:11:49.480Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-02T02:11:49.492Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-02T02:12:01.480Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-02T02:12:01.492Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-02T02:12:13.476Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:12:13.492Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-02T02:12:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:12:25.476Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T02:12:25.488Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.7)
2025-11-02T02:12:37.476Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-02T02:12:49.472Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-02T02:13:01.472Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-02T02:13:13.472Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-02T02:13:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:13:25.468Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-02T02:13:25.484Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.2)
2025-11-02T02:13:37.468Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-02T02:13:37.480Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-02T02:13:49.468Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-02T02:13:49.480Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-02T02:14:01.464Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-02T02:14:01.480Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-02T02:14:13.464Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-02T02:14:13.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-02T02:14:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:14:25.464Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:14:25.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-02T02:14:37.460Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T02:14:37.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.7)
2025-11-02T02:14:49.460Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:15:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T02:15:01.460Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T02:15:08.652Z:INFO:active_lb.c:308:SMt:(15.0 15.0 15.0)A Free:(1.0 1.0 1.0)A ALB:(14.7 14.7 15.0)A
2025-11-02T02:15:13.457Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-02T02:15:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:15:23.500Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-02T02:15:23.511Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-02T02:15:23.519Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-02T02:15:23.527Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-02T02:15:23.808Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-02T02:15:24.515Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-02T02:15:25.457Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->8.9 due to current limit: Active-LoadBalancing
2025-11-02T02:15:25.527Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.8% (8.9 A)
2025-11-02T02:15:37.457Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->5.4 due to current limit: Active-LoadBalancing
2025-11-02T02:15:37.468Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.36) < minimum current(6.00)
2025-11-02T02:15:37.500Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-02T02:15:37.511Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-02T02:15:37.519Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-02T02:15:37.644Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-02T02:15:38.496Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-11-02T02:15:38.496Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-02T02:15:49.453Z:INFO:taskMain.c:5996:Socket #1: Active current 5.4->8.8 due to current limit: Active-LoadBalancing
2025-11-02T02:15:49.500Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-02T02:15:49.507Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-02T02:15:49.519Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-02T02:15:49.605Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-02T02:15:50.503Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-02T02:16:01.453Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->10.9 due to current limit: Active-LoadBalancing
2025-11-02T02:16:01.613Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.1% (10.9 A)
2025-11-02T02:16:13.453Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->12.1 due to current limit: Active-LoadBalancing
2025-11-02T02:16:13.730Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.2% (12.1 A)
2025-11-02T02:16:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:16:19.546Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-02T02:16:19.554Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-02T02:16:19.792Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-02T02:16:19.800Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-02T02:16:20.542Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-02T02:16:23.546Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-02T02:16:23.570Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-02T02:16:23.578Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-02T02:16:24.046Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-02T02:16:24.054Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-02T02:16:24.582Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-02T02:16:25.070Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-02T02:16:25.449Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.9 due to current limit: Active-LoadBalancing
2025-11-02T02:16:26.082Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.4% (12.8 A)
2025-11-02T02:16:37.449Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.3 due to current limit: Active-LoadBalancing
2025-11-02T02:16:38.199Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.2% (13.3 A)
2025-11-02T02:16:49.449Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->14.0 due to current limit: Active-LoadBalancing
2025-11-02T02:16:50.316Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.3% (14.0 A)
2025-11-02T02:17:01.445Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:17:02.437Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.9% (14.3 A)
2025-11-02T02:17:13.445Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-02T02:17:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:17:25.445Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-02T02:17:49.441Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-02T02:18:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:18:49.437Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-02T02:18:49.484Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-02T02:19:01.433Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:19:13.433Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T02:19:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:19:37.429Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-02T02:20:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:20:22.621Z:USER:taskMaster.c:6582:Temperature: 30.2 C
2025-11-02T02:20:37.425Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:20:37.542Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-02T02:20:49.421Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-02T02:21:01.421Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-02T02:21:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:21:25.417Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.6 due to current limit: Active-LoadBalancing
2025-11-02T02:21:37.417Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-02T02:22:01.414Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-02T02:22:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:22:31.156Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.1V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:22:31.167Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T02:23:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:24:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:25:08.589Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T02:25:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:26:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:27:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:28:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:29:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:30:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T02:30:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:30:25.363Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-02T02:30:26.312Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-02T02:30:37.359Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:30:49.359Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T02:31:13.355Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-02T02:31:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:32:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:33:01.347Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:33:01.835Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-02T02:33:13.343Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-02T02:33:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:33:21.886Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-02T02:33:21.898Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-02T02:33:21.906Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.2V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:33:21.917Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T02:33:21.929Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-02T02:33:21.937Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-02T02:33:21.945Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-02T02:33:22.035Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-02T02:33:22.894Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-02T02:33:24.722Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->15.0 due to current limit: Active-LoadBalancing
2025-11-02T02:33:25.386Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-02T02:33:25.738Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-02T02:33:29.722Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-02T02:33:37.343Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.9 due to current limit: ChargingProfile
2025-11-02T02:33:37.386Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-02T02:33:38.042Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-02T02:33:51.933Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=232.7V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:33:51.945Z:USER:taskMaster.c:6720:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-11-02T02:34:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:34:21.878Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-02T02:34:21.929Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=232.4V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:34:21.945Z:USER:taskMaster.c:6720:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-11-02T02:34:25.335Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.4 due to current limit: Active-LoadBalancing
2025-11-02T02:34:25.347Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->25.7)
2025-11-02T02:34:25.378Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-02T02:34:25.507Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.7% (15.4 A)
2025-11-02T02:34:37.335Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->14.9 due to current limit: Active-LoadBalancing
2025-11-02T02:34:37.347Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->24.8)
2025-11-02T02:34:37.625Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.8% (14.9 A)
2025-11-02T02:34:49.335Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-02T02:34:49.347Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-02T02:34:51.929Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=232.7V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:34:51.941Z:USER:taskMaster.c:6720:Socket #1: I1=14.4A I2=14.4A I3=14.3A P=10.0kW Idc=0.7mA
2025-11-02T02:35:01.332Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-02T02:35:01.347Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T02:35:08.527Z:INFO:active_lb.c:308:SMt:(15.0 16.0 15.0)A Free:(1.0 0.0 1.0)A ALB:(15.6 14.6 15.4)A
2025-11-02T02:35:13.332Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-02T02:35:13.343Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.1)
2025-11-02T02:35:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:35:21.925Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=232.9V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:35:21.937Z:USER:taskMaster.c:6720:Socket #1: I1=14.0A I2=14.1A I3=14.0A P=9.8kW Idc=0.7mA
2025-11-02T02:35:22.976Z:USER:taskMaster.c:6582:Temperature: 28.5 C
2025-11-02T02:35:25.332Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-02T02:35:25.343Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-02T02:35:37.328Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T02:35:49.328Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-02T02:35:51.921Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=232.8V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:35:51.933Z:USER:taskMaster.c:6720:Socket #1: I1=14.4A I2=14.4A I3=14.3A P=10.0kW Idc=0.7mA
2025-11-02T02:36:01.328Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-02T02:36:01.339Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-02T02:36:13.324Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-02T02:36:13.339Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-02T02:36:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:36:21.917Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=232.9V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:36:21.929Z:USER:taskMaster.c:6720:Socket #1: I1=14.0A I2=14.1A I3=14.0A P=9.8kW Idc=0.7mA
2025-11-02T02:36:25.324Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-02T02:36:25.335Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-02T02:36:37.324Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-02T02:36:49.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:36:49.335Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->24.0)
2025-11-02T02:36:51.914Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=232.9V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:36:51.929Z:USER:taskMaster.c:6720:Socket #1: I1=14.0A I2=14.1A I3=14.0A P=9.8kW Idc=0.7mA
2025-11-02T02:37:01.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T02:37:01.332Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T02:37:13.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T02:37:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:37:21.914Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=232.9V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:37:21.925Z:USER:taskMaster.c:6720:Socket #1: I1=14.2A I2=14.2A I3=14.2A P=9.9kW Idc=0.7mA
2025-11-02T02:37:25.316Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-02T02:37:37.316Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-02T02:37:37.328Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-02T02:37:49.316Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-02T02:37:49.328Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-02T02:37:51.910Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=233.1V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:37:51.921Z:USER:taskMaster.c:6720:Socket #1: I1=14.0A I2=14.1A I3=14.0A P=9.8kW Idc=0.7mA
2025-11-02T02:38:01.312Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-02T02:38:01.328Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-02T02:38:13.312Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-02T02:38:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:38:21.906Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=233.1V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:38:21.917Z:USER:taskMaster.c:6720:Socket #1: I1=14.2A I2=14.2A I3=14.2A P=9.9kW Idc=0.7mA
2025-11-02T02:38:21.929Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-02T02:38:25.312Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-02T02:38:37.308Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-02T02:38:37.324Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-02T02:38:49.308Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-02T02:38:49.320Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-02T02:39:01.308Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:39:01.320Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->24.0)
2025-11-02T02:39:13.304Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T02:39:13.320Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T02:39:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:39:25.304Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-02T02:39:37.304Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-02T02:39:49.300Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-02T02:39:49.316Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-02T02:40:01.300Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-02T02:40:01.312Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-02T02:40:13.300Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-02T02:40:13.312Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.9)
2025-11-02T02:40:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:40:25.300Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-02T02:40:37.296Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-02T02:40:49.296Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-02T02:40:49.308Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-02T02:41:01.296Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T02:41:01.308Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T02:41:13.292Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:41:13.308Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T02:41:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:41:25.292Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T02:41:25.304Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-02T02:41:37.292Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-02T02:41:37.304Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-02T02:41:49.289Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->13.7 due to current limit: Active-LoadBalancing
2025-11-02T02:41:49.304Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.5->22.9)
2025-11-02T02:41:49.859Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.9% (13.7 A)
2025-11-02T02:42:01.289Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->14.2 due to current limit: Active-LoadBalancing
2025-11-02T02:42:01.980Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.6% (14.2 A)
2025-11-02T02:42:13.289Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:42:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:42:25.285Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T02:42:37.285Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-02T02:42:37.296Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-02T02:42:49.285Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:42:49.296Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->24.0)
2025-11-02T02:43:01.281Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T02:43:01.296Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.7)
2025-11-02T02:43:13.281Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-02T02:43:13.292Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.7->23.5)
2025-11-02T02:43:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:43:25.281Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.0 due to current limit: Active-LoadBalancing
2025-11-02T02:43:25.292Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.5->23.3)
2025-11-02T02:43:37.277Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.2 due to current limit: Active-LoadBalancing
2025-11-02T02:43:49.277Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-02T02:44:01.277Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-02T02:44:01.289Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.9)
2025-11-02T02:44:13.273Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-02T02:44:13.289Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.6)
2025-11-02T02:44:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:44:25.273Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.0 due to current limit: Active-LoadBalancing
2025-11-02T02:44:25.285Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.6->23.3)
2025-11-02T02:44:37.273Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.2 due to current limit: Active-LoadBalancing
2025-11-02T02:44:49.269Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-02T02:45:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T02:45:01.269Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:45:01.281Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.9)
2025-11-02T02:45:08.464Z:INFO:active_lb.c:308:SMt:(14.0 16.0 15.0)A Free:(2.0 0.0 1.0)A ALB:(15.9 14.4 15.3)A
2025-11-02T02:45:13.269Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T02:45:13.281Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.6)
2025-11-02T02:45:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:45:23.062Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-02T02:45:23.070Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-02T02:45:23.082Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-02T02:45:23.089Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-02T02:45:23.957Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-02T02:45:24.078Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-02T02:45:25.265Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->8.5 due to current limit: Active-LoadBalancing
2025-11-02T02:45:26.097Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.2% (8.5 A)
2025-11-02T02:45:37.265Z:INFO:taskMain.c:5996:Socket #1: Active current 8.5->5.5 due to current limit: Active-LoadBalancing
2025-11-02T02:45:37.277Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.52) < minimum current(6.00)
2025-11-02T02:45:37.308Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-02T02:45:37.320Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-02T02:45:37.328Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-02T02:45:38.214Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-02T02:45:38.304Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-11-02T02:45:38.304Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-02T02:45:49.265Z:INFO:taskMain.c:5996:Socket #1: Active current 5.5->8.9 due to current limit: Active-LoadBalancing
2025-11-02T02:45:49.308Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-02T02:45:49.320Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-02T02:45:49.328Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-02T02:45:49.414Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-02T02:45:49.421Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.8% (8.9 A)
2025-11-02T02:45:50.316Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-02T02:46:01.261Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->10.9 due to current limit: Active-LoadBalancing
2025-11-02T02:46:01.421Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.2% (10.9 A)
2025-11-02T02:46:13.261Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->12.2 due to current limit: Active-LoadBalancing
2025-11-02T02:46:13.542Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.2% (12.1 A)
2025-11-02T02:46:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:46:19.355Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-02T02:46:19.363Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-02T02:46:19.601Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-02T02:46:19.609Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-02T02:46:20.351Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-02T02:46:23.355Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-02T02:46:23.382Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-02T02:46:23.386Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-02T02:46:23.855Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-02T02:46:23.863Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-02T02:46:24.390Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-02T02:46:24.878Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-02T02:46:25.261Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.9 due to current limit: Active-LoadBalancing
2025-11-02T02:46:25.890Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.5% (12.9 A)
2025-11-02T02:46:37.257Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.3 due to current limit: Active-LoadBalancing
2025-11-02T02:46:38.007Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.2% (13.3 A)
2025-11-02T02:46:49.257Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.6 due to current limit: Active-LoadBalancing
2025-11-02T02:47:01.257Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-02T02:47:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:47:25.253Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-02T02:48:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:48:17.042Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000006, address 0x00006000 (1)
2025-11-02T02:48:17.054Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-02T02:49:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:50:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:50:23.378Z:USER:taskMaster.c:6582:Temperature: 28.9 C
2025-11-02T02:51:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:51:16.472Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-02T02:51:16.484Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-02T02:51:16.492Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=235.0V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:51:16.503Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T02:51:16.515Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-02T02:51:16.523Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-02T02:51:16.531Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-02T02:51:16.738Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-02T02:51:17.468Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-02T02:51:19.250Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->15.0 due to current limit: Active-LoadBalancing
2025-11-02T02:51:19.488Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.9% (14.9 A)
2025-11-02T02:51:24.250Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.0 due to current limit: Active-LoadBalancing
2025-11-02T02:51:24.261Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->23.3)
2025-11-02T02:51:24.539Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.3% (14.0 A)
2025-11-02T02:51:25.273Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-02T02:51:29.250Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->15.9 due to current limit: ChargingProfile
2025-11-02T02:51:29.589Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-02T02:51:46.519Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=233.4V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:51:46.535Z:USER:taskMaster.c:6720:Socket #1: I1=15.6A I2=15.5A I3=15.6A P=10.9kW Idc=0.7mA
2025-11-02T02:52:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:52:16.453Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-02T02:52:16.519Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=233.4V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:52:16.531Z:USER:taskMaster.c:6720:Socket #1: I1=15.6A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-11-02T02:52:25.222Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->26.4)
2025-11-02T02:52:25.265Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-02T02:52:37.222Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.3 due to current limit: Active-LoadBalancing
2025-11-02T02:52:37.234Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.4->25.5)
2025-11-02T02:52:37.246Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.5% (15.3 A)
2025-11-02T02:52:46.515Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=233.4V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:52:46.527Z:USER:taskMaster.c:6720:Socket #1: I1=14.9A I2=15.0A I3=14.9A P=10.5kW Idc=0.7mA
2025-11-02T02:52:49.218Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->14.8 due to current limit: Active-LoadBalancing
2025-11-02T02:52:49.234Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->24.6)
2025-11-02T02:52:49.359Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.6% (14.8 A)
2025-11-02T02:53:01.218Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.2 due to current limit: Active-LoadBalancing
2025-11-02T02:53:01.230Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->23.7)
2025-11-02T02:53:01.480Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.7% (14.2 A)
2025-11-02T02:53:13.218Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.1 due to current limit: Active-LoadBalancing
2025-11-02T02:53:13.230Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.7->23.4)
2025-11-02T02:53:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:53:16.511Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=233.4V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:53:16.523Z:USER:taskMaster.c:6720:Socket #1: I1=13.6A I2=13.7A I3=13.6A P=9.6kW Idc=0.7mA
2025-11-02T02:53:25.214Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->13.9 due to current limit: Active-LoadBalancing
2025-11-02T02:53:25.230Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.4->23.2)
2025-11-02T02:53:37.214Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->14.2 due to current limit: Active-LoadBalancing
2025-11-02T02:53:46.507Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=233.4V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:53:46.519Z:USER:taskMaster.c:6720:Socket #1: I1=13.8A I2=13.8A I3=13.8A P=9.6kW Idc=0.7mA
2025-11-02T02:53:49.214Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:54:01.210Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T02:54:13.210Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-02T02:54:13.222Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-02T02:54:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:54:16.503Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=233.5V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:54:16.519Z:USER:taskMaster.c:6720:Socket #1: I1=14.2A I2=14.2A I3=14.2A P=9.9kW Idc=0.7mA
2025-11-02T02:54:25.210Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:54:25.222Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-02T02:54:37.210Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T02:54:37.222Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.7)
2025-11-02T02:54:46.503Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=233.4V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:54:46.515Z:USER:taskMaster.c:6720:Socket #1: I1=13.9A I2=13.9A I3=13.8A P=9.7kW Idc=0.7mA
2025-11-02T02:54:49.207Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.1 due to current limit: Active-LoadBalancing
2025-11-02T02:54:49.218Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.7->23.4)
2025-11-02T02:55:01.207Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->13.9 due to current limit: Active-LoadBalancing
2025-11-02T02:55:01.218Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.4->23.2)
2025-11-02T02:55:08.398Z:INFO:active_lb.c:308:SMt:(15.0 16.0 15.0)A Free:(1.0 0.0 1.0)A ALB:(15.4 13.9 14.9)A
2025-11-02T02:55:13.207Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->14.2 due to current limit: Active-LoadBalancing
2025-11-02T02:55:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:55:16.500Z:USER:taskMaster.c:6684:Socket #1: L1N=233.3V L2N=233.4V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:55:16.511Z:USER:taskMaster.c:6720:Socket #1: I1=13.7A I2=13.8A I3=13.8A P=9.6kW Idc=0.7mA
2025-11-02T02:55:25.203Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:55:37.203Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T02:55:46.496Z:USER:taskMaster.c:6684:Socket #1: L1N=233.4V L2N=233.3V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:55:46.507Z:USER:taskMaster.c:6720:Socket #1: I1=14.2A I2=14.3A I3=14.2A P=10.0kW Idc=0.7mA
2025-11-02T02:55:49.203Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-02T02:55:49.214Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-02T02:56:01.199Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:56:01.210Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-02T02:56:13.199Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T02:56:13.210Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.6)
2025-11-02T02:56:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:56:16.492Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=233.3V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T02:56:16.503Z:USER:taskMaster.c:6720:Socket #1: I1=13.7A I2=13.8A I3=13.7A P=9.6kW Idc=0.7mA
2025-11-02T02:56:16.515Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-02T02:56:25.199Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.0 due to current limit: Active-LoadBalancing
2025-11-02T02:56:25.210Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.6->23.3)
2025-11-02T02:56:37.195Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.2 due to current limit: Active-LoadBalancing
2025-11-02T02:56:49.195Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-02T02:57:01.195Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-02T02:57:13.191Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-02T02:57:13.207Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-02T02:57:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:57:25.191Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T02:57:25.203Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-02T02:57:37.191Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T02:57:49.187Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-02T02:58:01.187Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-02T02:58:13.187Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-02T02:58:13.199Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-02T02:58:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:58:25.183Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-02T02:58:25.199Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-02T02:58:34.828Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-02T02:58:34.835Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-02T02:58:34.847Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-02T02:58:34.855Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-02T02:58:35.753Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-02T02:58:35.863Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-02T02:58:37.183Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->8.9 due to current limit: Active-LoadBalancing
2025-11-02T02:58:37.882Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.8% (8.9 A)
2025-11-02T02:58:49.183Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->5.3 due to current limit: Active-LoadBalancing
2025-11-02T02:58:49.195Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.34) < minimum current(6.00)
2025-11-02T02:58:49.226Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-02T02:58:49.238Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-02T02:58:49.246Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-02T02:58:50.003Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-02T02:58:50.222Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-11-02T02:58:50.222Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-02T02:59:01.179Z:INFO:taskMain.c:5996:Socket #1: Active current 5.3->9.2 due to current limit: Active-LoadBalancing
2025-11-02T02:59:01.226Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-02T02:59:01.234Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-02T02:59:01.246Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-02T02:59:01.332Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-02T02:59:02.230Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-02T02:59:13.179Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->11.5 due to current limit: Active-LoadBalancing
2025-11-02T02:59:13.339Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.2% (11.5 A)
2025-11-02T02:59:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T02:59:25.179Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->12.9 due to current limit: Active-LoadBalancing
2025-11-02T02:59:25.457Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.5% (12.9 A)
2025-11-02T02:59:31.273Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-02T02:59:31.281Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-02T02:59:31.519Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-02T02:59:31.527Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-02T02:59:32.269Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-02T02:59:35.269Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-02T02:59:35.296Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-02T02:59:35.304Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-02T02:59:35.773Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-02T02:59:35.781Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-02T02:59:36.308Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-02T02:59:36.796Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-02T02:59:37.175Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.7 due to current limit: Active-LoadBalancing
2025-11-02T02:59:37.808Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.9% (13.7 A)
2025-11-02T02:59:49.175Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->14.2 due to current limit: Active-LoadBalancing
2025-11-02T02:59:49.925Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.7% (14.2 A)
2025-11-02T03:00:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T03:00:01.175Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-02T03:00:13.171Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-02T03:00:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:00:25.171Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-02T03:00:30.320Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-02T03:00:30.328Z:INFO:db_chargingprofi:26: socket 0
2025-11-02T03:00:30.335Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-02T03:00:30.347Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-02T03:00:30.355Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-02T03:00:30.363Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-02T03:00:30.375Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-02T03:00:30.382Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-02T03:00:30.390Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-02T03:00:30.398Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-02T03:00:30.406Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-02T03:00:30.414Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-02T03:00:30.421Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-02T03:00:30.429Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-02T03:00:30.437Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-02T03:00:30.449Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-02T03:00:30.457Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-02T03:00:30.464Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-02T03:00:30.476Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-02T03:00:30.484Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-02T03:00:30.492Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-02T03:00:30.500Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-02T03:00:30.507Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-02T03:00:49.167Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-02T03:01:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:02:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:03:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:04:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:05:08.335Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T03:05:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:05:23.785Z:USER:taskMaster.c:6582:Temperature: 28.4 C
2025-11-02T03:06:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:07:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:08:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:09:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:10:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:10:49.105Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->13.4 due to current limit: Active-LoadBalancing
2025-11-02T03:10:49.386Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-02T03:11:01.105Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->14.0 due to current limit: Active-LoadBalancing
2025-11-02T03:11:01.503Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.4% (14.0 A)
2025-11-02T03:11:13.105Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-02T03:11:13.625Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-02T03:11:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:11:16.398Z:USER:taskMaster.c:6684:Socket #1: L1N=235.1V L2N=235.3V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T03:11:16.410Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T03:11:25.101Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-02T03:11:37.101Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-02T03:12:01.097Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-02T03:12:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:13:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:14:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:15:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T03:15:08.273Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T03:15:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:16:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:17:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:18:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:19:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:20:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:20:24.140Z:USER:taskMaster.c:6582:Temperature: 26.9 C
2025-11-02T03:21:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:22:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:23:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:24:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:25:08.210Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T03:25:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:26:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:26:16.304Z:USER:taskMaster.c:6684:Socket #1: L1N=235.4V L2N=235.8V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T03:26:16.316Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T03:27:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:28:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:29:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:30:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T03:30:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:31:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:32:00.972Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-02T03:32:01.851Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-02T03:32:12.972Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T03:32:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:32:24.968Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T03:32:36.968Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-02T03:32:37.199Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-02T03:32:48.968Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-02T03:33:00.964Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-02T03:33:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:33:24.964Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-02T03:34:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:34:59.996Z:INFO:heap_trace.c:493:free: 69232/160768 (43.1%) min: 37040 (23.0%) alloc #: 197
2025-11-02T03:35:00.007Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.2% free blocks: # 16 largest: 40992
2025-11-02T03:35:08.148Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T03:35:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:35:24.546Z:USER:taskMaster.c:6582:Temperature: 25.8 C
2025-11-02T03:36:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:37:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:37:24.937Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-02T03:37:25.019Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-02T03:37:36.988Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-02T03:37:48.984Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T03:38:12.984Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-02T03:38:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:39:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:40:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:41:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:41:16.207Z:USER:taskMaster.c:6684:Socket #1: L1N=235.7V L2N=235.6V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T03:41:16.222Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T03:42:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:43:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:44:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:45:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T03:45:08.082Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-02T03:45:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:46:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:47:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:48:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:49:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:49:16.609Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000007, address 0x00007000 (1)
2025-11-02T03:49:16.621Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-02T03:50:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:50:24.902Z:USER:taskMaster.c:6582:Temperature: 24.9 C
2025-11-02T03:51:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:52:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:53:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:53:48.933Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-02T03:53:49.664Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-02T03:54:00.933Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-02T03:54:12.933Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-02T03:54:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:54:36.929Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-02T03:55:08.019Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T03:55:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:56:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:56:16.113Z:USER:taskMaster.c:6684:Socket #1: L1N=236.0V L2N=236.0V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T03:56:16.125Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T03:57:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:58:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T03:59:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:00:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T04:00:12.894Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->13.4 due to current limit: Active-LoadBalancing
2025-11-02T04:00:13.425Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-02T04:00:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:00:24.894Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->12.4 due to current limit: Active-LoadBalancing
2025-11-02T04:00:25.542Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-11-02T04:00:36.890Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->11.9 due to current limit: Active-LoadBalancing
2025-11-02T04:00:37.660Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.7% (11.8 A)
2025-11-02T04:00:37.890Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-02T04:00:37.898Z:INFO:db_chargingprofi:26: socket 0
2025-11-02T04:00:37.906Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-02T04:00:37.914Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-02T04:00:37.921Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-02T04:00:37.929Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-02T04:00:37.941Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-02T04:00:37.949Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-02T04:00:37.960Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-02T04:00:37.968Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-02T04:00:37.976Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-02T04:00:37.984Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-02T04:00:37.992Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-02T04:00:38.000Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-02T04:00:38.007Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-02T04:00:38.015Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-02T04:00:38.027Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-02T04:00:38.035Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-02T04:00:38.042Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-02T04:00:38.050Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-02T04:00:38.058Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-02T04:00:38.066Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-02T04:00:38.074Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-02T04:00:48.890Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.5 due to current limit: Active-LoadBalancing
2025-11-02T04:00:49.781Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.1% (11.5 A)
2025-11-02T04:00:54.433Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-02T04:00:54.441Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-02T04:00:54.453Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=236.1V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T04:00:54.464Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T04:00:54.476Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-02T04:00:54.484Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-02T04:00:54.492Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-02T04:00:54.828Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-02T04:00:54.933Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-02T04:00:54.945Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-02T04:00:54.953Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-02T04:00:54.960Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-02T04:00:55.839Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-02T04:00:55.949Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-02T04:01:00.890Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-02T04:01:12.886Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-02T04:01:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:01:24.480Z:USER:taskMaster.c:6684:Socket #1: L1N=236.2V L2N=236.4V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T04:01:24.492Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T04:01:36.886Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.1 due to current limit: Active-LoadBalancing
2025-11-02T04:01:54.421Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-02T04:01:54.476Z:USER:taskMaster.c:6684:Socket #1: L1N=236.4V L2N=236.3V L3N=236.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T04:01:54.488Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T04:02:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:02:24.472Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=236.2V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T04:02:24.488Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T04:02:54.472Z:USER:taskMaster.c:6684:Socket #1: L1N=235.9V L2N=235.8V L3N=235.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T04:02:54.484Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T04:03:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:03:24.468Z:USER:taskMaster.c:6684:Socket #1: L1N=236.2V L2N=235.9V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T04:03:24.480Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T04:03:54.464Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=236.2V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T04:03:54.476Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T04:04:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:04:24.460Z:USER:taskMaster.c:6684:Socket #1: L1N=236.2V L2N=236.1V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T04:04:24.472Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T04:04:54.457Z:USER:taskMaster.c:6684:Socket #1: L1N=236.2V L2N=235.8V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T04:04:54.468Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T04:05:07.957Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-02T04:05:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:05:24.457Z:USER:taskMaster.c:6684:Socket #1: L1N=236.2V L2N=236.1V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T04:05:24.468Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T04:05:25.304Z:USER:taskMaster.c:6582:Temperature: 24.4 C
2025-11-02T04:05:54.453Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=236.2V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T04:05:54.464Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T04:05:54.476Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-02T04:06:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:07:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:08:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:09:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:10:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:11:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:12:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:13:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:14:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:15:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T04:15:07.894Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-02T04:15:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:16:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:17:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:18:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:19:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:20:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:20:25.710Z:USER:taskMaster.c:6582:Temperature: 23.9 C
2025-11-02T04:20:54.355Z:USER:taskMaster.c:6684:Socket #1: L1N=236.5V L2N=236.1V L3N=236.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T04:20:54.371Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T04:21:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:22:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:23:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:24:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:25:07.832Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-02T04:25:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:26:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:27:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:28:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:29:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:30:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T04:30:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:31:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:32:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:33:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:34:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:35:07.765Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(15.0 14.0 11.0)A ALB:(15.0 14.0 11.0)A
2025-11-02T04:35:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:35:26.066Z:USER:taskMaster.c:6582:Temperature: 23.5 C
2025-11-02T04:35:54.261Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=235.8V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T04:35:54.273Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T04:36:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:37:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:38:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:39:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:40:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:41:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:42:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:43:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:44:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:45:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T04:45:07.703Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(15.0 14.0 11.0)A ALB:(15.0 14.0 11.0)A
2025-11-02T04:45:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:46:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:47:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:48:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:49:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:50:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:50:26.468Z:USER:taskMaster.c:6582:Temperature: 23.4 C
2025-11-02T04:50:54.167Z:USER:taskMaster.c:6684:Socket #1: L1N=235.3V L2N=235.4V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T04:50:54.179Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T04:51:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:51:17.015Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000008, address 0x00008000 (1)
2025-11-02T04:51:17.027Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-02T04:52:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:53:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:54:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:55:07.640Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-02T04:55:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:56:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:57:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:58:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T04:59:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:00:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T05:00:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:00:45.410Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-02T05:00:45.421Z:INFO:db_chargingprofi:26: socket 0
2025-11-02T05:00:45.429Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-02T05:00:45.437Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-02T05:00:45.445Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-02T05:00:45.453Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-02T05:00:45.464Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-02T05:00:45.472Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-02T05:00:45.480Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-02T05:00:45.488Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-02T05:00:45.496Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-02T05:00:45.503Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-02T05:00:45.511Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-02T05:00:45.523Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-02T05:00:45.527Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-02T05:00:45.539Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-02T05:00:45.546Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-02T05:00:45.554Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-02T05:00:45.566Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-02T05:00:45.574Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-02T05:00:45.582Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-02T05:00:45.589Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-02T05:00:45.597Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-02T05:01:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:02:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:03:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:04:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:05:07.574Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-02T05:05:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:05:26.726Z:USER:taskMaster.c:6582:Temperature: 23.4 C
2025-11-02T05:05:54.070Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.5V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T05:05:54.082Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T05:06:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:07:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:08:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:09:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:10:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:11:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:12:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:13:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:14:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:15:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T05:15:07.511Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-02T05:15:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:16:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:17:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:18:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:19:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:20:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:20:27.128Z:USER:taskMaster.c:6582:Temperature: 23.2 C
2025-11-02T05:20:53.976Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.2V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T05:20:53.988Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T05:21:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:22:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:23:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:24:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:25:07.449Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-02T05:25:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:26:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:27:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:28:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:29:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:30:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T05:30:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:31:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:32:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:33:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:34:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:34:52.363Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-02T05:34:52.632Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-02T05:34:59.234Z:INFO:heap_trace.c:493:free: 69232/160768 (43.1%) min: 37040 (23.0%) alloc #: 197
2025-11-02T05:34:59.246Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.2% free blocks: # 16 largest: 40992
2025-11-02T05:35:07.386Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(15.0 14.0 11.0)A ALB:(15.0 14.0 11.0)A
2025-11-02T05:35:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:35:27.535Z:USER:taskMaster.c:6582:Temperature: 23.1 C
2025-11-02T05:35:53.878Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=234.3V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T05:35:53.894Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T05:36:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:37:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:38:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:39:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:40:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:41:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:42:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:43:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:44:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:45:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T05:45:07.320Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(15.0 14.0 11.0)A ALB:(15.0 14.0 11.0)A
2025-11-02T05:45:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:46:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:47:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:48:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:49:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:50:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:50:27.886Z:USER:taskMaster.c:6582:Temperature: 23.0 C
2025-11-02T05:50:53.785Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=234.5V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T05:50:53.796Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T05:51:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:52:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:52:16.378Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000009, address 0x00009000 (1)
2025-11-02T05:52:16.386Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-02T05:53:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:54:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:55:07.257Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(15.0 14.0 11.0)A ALB:(15.0 14.0 11.0)A
2025-11-02T05:55:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:56:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:57:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:58:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T05:59:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:00:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T06:00:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:00:52.925Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-02T06:00:52.933Z:INFO:db_chargingprofi:26: socket 0
2025-11-02T06:00:52.941Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-02T06:00:52.949Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-02T06:00:52.957Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-02T06:00:52.968Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-02T06:00:52.976Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-02T06:00:52.992Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-02T06:00:53.000Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-02T06:00:53.007Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-02T06:00:53.015Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-02T06:00:53.023Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-02T06:00:53.031Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-02T06:00:53.039Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-02T06:00:53.046Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-02T06:00:53.058Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-02T06:00:53.066Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-02T06:00:53.074Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-02T06:00:53.082Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-02T06:00:53.089Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-02T06:00:53.097Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-02T06:00:53.105Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-02T06:00:53.113Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-02T06:01:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:02:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:03:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:04:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:05:07.195Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(15.0 14.0 11.0)A ALB:(15.0 14.0 11.0)A
2025-11-02T06:05:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:05:28.292Z:USER:taskMaster.c:6582:Temperature: 22.8 C
2025-11-02T06:05:53.691Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=234.8V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T06:05:53.703Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T06:06:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:06:35.488Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-11-02T06:07:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:08:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:09:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:10:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:11:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:12:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:13:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:14:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:15:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T06:15:07.132Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(15.0 14.0 11.0)A ALB:(15.0 14.0 11.0)A
2025-11-02T06:15:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:16:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:16:35.527Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-11-02T06:17:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:18:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:19:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:20:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:20:28.648Z:USER:taskMaster.c:6582:Temperature: 22.6 C
2025-11-02T06:20:53.593Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.4V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T06:20:53.605Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T06:21:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:22:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:23:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:24:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:25:07.066Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-02T06:25:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:26:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:26:35.460Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-11-02T06:27:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:28:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:29:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:30:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T06:30:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:31:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:32:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:33:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:34:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:35:07.003Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-02T06:35:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:35:29.050Z:USER:taskMaster.c:6582:Temperature: 22.8 C
2025-11-02T06:35:53.500Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.2V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T06:35:53.511Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T06:36:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:37:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:38:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:39:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:40:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:41:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:42:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:43:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:44:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:45:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T06:45:06.941Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-02T06:45:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:46:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:47:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:48:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:49:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:50:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:50:29.457Z:USER:taskMaster.c:6582:Temperature: 22.6 C
2025-11-02T06:50:53.402Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.3V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T06:50:53.414Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T06:51:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:52:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:53:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:53:16.386Z:INFO:db_base.c:658:Erasing Transaction db sector 0x0000000a, address 0x0000a000 (1)
2025-11-02T06:53:16.398Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-02T06:54:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:55:06.875Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-02T06:55:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:56:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:57:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:58:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T06:59:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:00:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T07:00:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:01:00.492Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-02T07:01:00.500Z:INFO:db_chargingprofi:26: socket 0
2025-11-02T07:01:00.507Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-02T07:01:00.519Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-02T07:01:00.527Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-02T07:01:00.535Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-02T07:01:00.546Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-02T07:01:00.554Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-02T07:01:00.562Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-02T07:01:00.570Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-02T07:01:00.578Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-02T07:01:00.589Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-02T07:01:00.597Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-02T07:01:00.605Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-02T07:01:00.613Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-02T07:01:00.625Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-02T07:01:00.632Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-02T07:01:00.640Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-02T07:01:00.652Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-02T07:01:00.660Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-02T07:01:00.667Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-02T07:01:00.675Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-02T07:01:00.683Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-02T07:01:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:02:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:03:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:04:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:05:06.812Z:INFO:active_lb.c:308:SMt:(2.0 1.0 5.0)A Free:(14.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-02T07:05:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:05:29.808Z:USER:taskMaster.c:6582:Temperature: 22.8 C
2025-11-02T07:05:53.308Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=233.7V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T07:05:53.320Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T07:06:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:07:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:08:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:09:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:10:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:11:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:12:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:13:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:14:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:15:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T07:15:06.750Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-02T07:15:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:16:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:17:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:18:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:19:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:20:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:20:30.164Z:USER:taskMaster.c:6582:Temperature: 23.0 C
2025-11-02T07:20:53.210Z:USER:taskMaster.c:6684:Socket #1: L1N=233.4V L2N=233.5V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T07:20:53.226Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T07:21:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:22:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:23:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:24:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:25:06.683Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(15.0 14.0 11.0)A ALB:(15.0 14.0 11.0)A
2025-11-02T07:25:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:26:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:27:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:28:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:29:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:30:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T07:30:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:31:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:32:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:33:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:34:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:34:58.472Z:INFO:heap_trace.c:493:free: 69232/160768 (43.1%) min: 37040 (23.0%) alloc #: 197
2025-11-02T07:34:58.480Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.2% free blocks: # 16 largest: 40992
2025-11-02T07:35:06.621Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(15.0 14.0 11.0)A ALB:(15.0 14.0 11.0)A
2025-11-02T07:35:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:35:30.519Z:USER:taskMaster.c:6582:Temperature: 23.1 C
2025-11-02T07:35:53.117Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=233.8V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T07:35:53.128Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T07:36:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:37:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:38:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:39:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:40:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:41:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:42:16.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:43:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:44:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:45:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T07:45:06.558Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(15.0 14.0 11.0)A ALB:(15.0 14.0 11.0)A
2025-11-02T07:45:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:46:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:47:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:47:35.648Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->12.6 due to current limit: Active-LoadBalancing
2025-11-02T07:47:36.179Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-11-02T07:47:47.648Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->13.6 due to current limit: Active-LoadBalancing
2025-11-02T07:47:48.296Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-02T07:47:59.644Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->14.0 due to current limit: Active-LoadBalancing
2025-11-02T07:48:00.414Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.3% (14.0 A)
2025-11-02T07:48:16.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:48:29.488Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-02T07:48:29.496Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-02T07:48:29.503Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=233.3V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T07:48:29.515Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T07:48:29.527Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-02T07:48:29.535Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-02T07:48:29.546Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-02T07:48:29.703Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-02T07:48:29.886Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-02T07:48:29.898Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-02T07:48:29.906Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-02T07:48:29.914Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-02T07:48:30.710Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-02T07:48:30.890Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-02T07:48:59.535Z:USER:taskMaster.c:6684:Socket #1: L1N=233.3V L2N=233.1V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T07:48:59.546Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T07:48:59.640Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-02T07:49:00.179Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-02T07:49:11.636Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T07:49:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:49:29.457Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-02T07:49:29.531Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=233.4V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T07:49:29.542Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T07:49:35.636Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-02T07:49:59.527Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=232.8V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T07:49:59.539Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T07:50:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:50:29.523Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=232.8V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T07:50:29.535Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T07:50:30.925Z:USER:taskMaster.c:6582:Temperature: 23.2 C
2025-11-02T07:50:59.519Z:USER:taskMaster.c:6684:Socket #1: L1N=233.4V L2N=232.5V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T07:50:59.531Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T07:50:59.625Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-02T07:51:00.355Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-02T07:51:11.625Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T07:51:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:51:29.519Z:USER:taskMaster.c:6684:Socket #1: L1N=233.3V L2N=232.8V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T07:51:29.531Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T07:51:35.621Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-02T07:51:59.515Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=233.4V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T07:51:59.527Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T07:52:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:52:29.511Z:USER:taskMaster.c:6684:Socket #1: L1N=233.4V L2N=233.0V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T07:52:29.523Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T07:52:59.507Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=233.4V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T07:52:59.519Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T07:53:16.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:53:29.503Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=233.2V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T07:53:29.515Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T07:53:29.527Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-02T07:54:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:54:16.898Z:INFO:db_base.c:658:Erasing Transaction db sector 0x0000000b, address 0x0000b000 (1)
2025-11-02T07:54:16.910Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-02T07:55:06.496Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-02T07:55:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:56:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:56:35.589Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-02T07:56:35.640Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-02T07:56:47.589Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T07:56:59.589Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-02T07:57:11.585Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-02T07:57:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:57:23.585Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-02T07:57:47.582Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-02T07:58:11.582Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-02T07:58:11.593Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-02T07:58:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T07:58:23.578Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-02T07:58:35.578Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-02T07:59:11.574Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.0 due to current limit: Active-LoadBalancing
2025-11-02T07:59:16.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T08:00:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T08:00:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T08:01:08.011Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-02T08:01:08.019Z:INFO:db_chargingprofi:26: socket 0
2025-11-02T08:01:08.027Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-02T08:01:08.035Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-02T08:01:08.042Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-02T08:01:08.050Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-02T08:01:08.062Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-02T08:01:08.070Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-02T08:01:08.082Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-02T08:01:08.089Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-02T08:01:08.097Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-02T08:01:08.105Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-02T08:01:08.113Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-02T08:01:08.121Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-02T08:01:08.128Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-02T08:01:08.136Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-02T08:01:08.144Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-02T08:01:08.156Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-02T08:01:08.164Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-02T08:01:08.171Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-02T08:01:08.179Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-02T08:01:08.191Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-02T08:01:08.199Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-02T08:01:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T08:02:16.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T08:03:16.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T08:04:16.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T08:05:06.429Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 1.0)A Free:(17.0 14.0 15.0)A ALB:(16.1 14.0 15.0)A
2025-11-02T08:05:16.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T08:05:23.535Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-02T08:05:23.816Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-02T08:05:31.328Z:USER:taskMaster.c:6582:Temperature: 23.2 C
2025-11-02T08:05:35.535Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-02T08:05:59.531Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-02T08:06:16.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T08:07:16.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T08:08:11.515Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.2 due to current limit: Active-LoadBalancing
2025-11-02T08:08:12.468Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.9% (13.1 A)
2025-11-02T08:08:16.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T08:08:23.515Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->14.0 due to current limit: Active-LoadBalancing
2025-11-02T08:08:23.574Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.3% (14.0 A)
2025-11-02T08:08:29.410Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=235.0V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T08:08:29.421Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-02T08:08:35.515Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.2 due to current limit: Active-LoadBalancing
2025-11-02T08:08:35.695Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.0% (13.2 A)
2025-11-02T08:08:47.511Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->12.3 due to current limit: Active-LoadBalancing
2025-11-02T08:08:47.812Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.5% (12.3 A)
2025-11-02T08:08:59.511Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->14.0 due to current limit: Active-LoadBalancing
2025-11-02T08:08:59.933Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.3% (14.0 A)
2025-11-02T08:09:16.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T08:10:16.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-02T08:10:16.894Z:WARNING:taskMain.c:4758:Socket #1: EV disconnected while charging (11.0V)
2025-11-02T08:10:16.949Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAIT_FOR_EV_RECONNECT
2025-11-02T08:10:16.957Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->0.0 due to current limit: Cable
2025-11-02T08:10:16.968Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_A
2025-11-02T08:10:17.046Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_TERMINATING
2025-11-02T08:10:17.058Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-02T08:10:17.066Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_VEHICLE
2025-11-02T08:10:17.695Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-02T08:10:17.703Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-02T08:10:17.710Z:INFO:taskMain.c:6504:Socket #1: PP 34464 Ohm (0 A)
2025-11-02T08:10:18.042Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_TERMINATING, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-02T08:10:21.046Z:INFO:taskMaster.c:4957:Socket #1: state main : WAIT_FOR_STOP_METERVALUE
2025-11-02T08:10:21.992Z:INFO:taskMain.c:938:Socket #1: charging session status set inactive
2025-11-02T08:10:22.003Z:INFO:taskMaster.c:4957:Socket #1: state main : WAIT_FOR_DISCONNECT
2025-11-02T08:10:22.011Z:USER:board_ng9xx.c:5068:Socket #1: unlock socket motor
2025-11-02T08:10:22.269Z:INFO:db_transaction.c:16:Added TransactionStop for socket 1 at 0x0000b46b (ts: 2025-11-02 08:10:22)
2025-11-02T08:10:22.285Z:INFO:db_transaction.c:16:Updated TransactionStart for socket 1 at 0x00001edb (ts: 2025-11-01 22:41:15)
2025-11-02T08:10:22.347Z:INFO:taskMaster.c:4979:Socket #1: state led : AVAILABLE
2025-11-02T08:10:22.386Z:INFO:taskMaster.c:4957:Socket #1: state main : AVAILABLE
2025-11-02T08:10:22.402Z:INFO:taskMain.c:6440:Socket #1: active tag cleared
2025-11-02T08:10:23.332Z:INFO:taskMain.c:1419:Socket #1: main state: AVAILABLE, CP: 0.0/0.0, no tag
2025-11-02T08:15:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T08:15:06.367Z:INFO:active_lb.c:308:SMt:(9.0 2.0 2.0)A Free:(7.0 14.0 14.0)A ALB:(7.8 14.5 14.0)A
2025-11-02T08:20:31.632Z:USER:taskMaster.c:6582:Temperature: 23.2 C
2025-11-02T08:23:29.312Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=233.5V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T08:25:06.304Z:INFO:active_lb.c:308:SMt:(3.0 3.0 2.0)A Free:(13.0 13.0 14.0)A ALB:(13.0 13.0 14.0)A
2025-11-02T08:30:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T08:35:06.242Z:INFO:active_lb.c:308:SMt:(-2.0 7.0 1.0)A Free:(18.0 9.0 15.0)A ALB:(17.5 9.0 15.0)A
2025-11-02T08:35:32.039Z:USER:taskMaster.c:6582:Temperature: 23.2 C
2025-11-02T08:38:29.218Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=233.4V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T08:45:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T08:45:06.175Z:INFO:active_lb.c:308:SMt:(-2.0 2.0 1.0)A Free:(18.0 14.0 15.0)A ALB:(17.9 12.9 15.0)A
2025-11-02T08:50:32.445Z:USER:taskMaster.c:6582:Temperature: 23.4 C
2025-11-02T08:53:29.125Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=234.6V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T08:55:06.113Z:INFO:active_lb.c:308:SMt:(-2.0 2.0 2.0)A Free:(18.0 14.0 14.0)A ALB:(18.0 14.0 14.0)A
2025-11-02T09:00:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T09:05:06.050Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 2.0)A Free:(17.0 14.0 14.0)A ALB:(16.6 14.2 14.0)A
2025-11-02T09:05:32.796Z:USER:taskMaster.c:6582:Temperature: 23.5 C
2025-11-02T09:08:29.027Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=233.3V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T09:15:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T09:15:05.984Z:INFO:active_lb.c:308:SMt:(-5.0 2.0 2.0)A Free:(21.0 14.0 14.0)A ALB:(15.1 14.0 14.0)A
2025-11-02T09:19:02.851Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-02T09:19:19.226Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x7880)
2025-11-02T09:19:19.238Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-02T09:19:19.261Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-02T09:19:20.988Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-02T09:19:21.128Z:SECURITY:taskWebClient.c:446:Received unauthorized request, so removing client
2025-11-02T09:19:21.140Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-02T09:19:21.226Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-02T09:19:22.929Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-02T09:19:23.230Z:SECURITY:httpd_login.c:155:WebClient ha connected (account: admin)
2025-11-02T09:20:33.250Z:USER:taskMaster.c:6582:Temperature: 23.9 C
2025-11-02T09:23:28.933Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=233.9V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T09:25:05.921Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(17.0 15.0 14.0)A ALB:(17.0 15.0 14.0)A
2025-11-02T09:30:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T09:34:50.613Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-02T09:34:50.878Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-02T09:34:57.707Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-02T09:34:57.718Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 16 largest: 40992
2025-11-02T09:35:05.859Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 2.0)A Free:(17.0 14.0 14.0)A ALB:(16.9 14.1 14.0)A
2025-11-02T09:35:06.007Z:INFO:comFaults.c:482:Reset fault status
2025-11-02T09:35:33.558Z:USER:taskMaster.c:6582:Temperature: 24.0 C
2025-11-02T09:38:28.835Z:USER:taskMaster.c:6684:Socket #1: L1N=236.2V L2N=235.0V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T09:45:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T09:45:05.796Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(16.2 14.1 14.0)A
2025-11-02T09:50:33.960Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-02T09:53:28.742Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=234.5V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T09:55:05.730Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(17.0 15.0 14.0)A ALB:(16.8 15.0 14.0)A
2025-11-02T10:00:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T10:00:56.089Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x7880)
2025-11-02T10:00:56.097Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-02T10:00:56.117Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-02T10:00:57.363Z:WARNING:taskWebClient.c:810:TLS handshake failed (-0x50) for fd=1
2025-11-02T10:00:57.371Z:WARNING:taskWebClient.c:834:Failed to setup WebClient -80
2025-11-02T10:00:58.617Z:WARNING:taskWebClient.c:810:TLS handshake failed (-0x50) for fd=1
2025-11-02T10:00:58.625Z:WARNING:taskWebClient.c:834:Failed to setup WebClient -80
2025-11-02T10:01:00.480Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-02T10:01:01.175Z:SECURITY:httpd_login.c:155:WebClient connected (account: admin)
2025-11-02T10:01:01.304Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-02T10:03:26.062Z:SECURITY:web_functionali:105:Webserver logout client 1
2025-11-02T10:03:26.082Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-02T10:03:26.136Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-02T10:05:05.667Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 2.0)A Free:(17.0 14.0 14.0)A ALB:(17.0 14.0 14.0)A
2025-11-02T10:05:34.367Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-02T10:07:31.437Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-02T10:07:54.851Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x7880)
2025-11-02T10:07:54.859Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-02T10:07:54.882Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-02T10:07:54.914Z:WARNING:taskWebClient.c:810:TLS handshake failed (-0x50) for fd=1
2025-11-02T10:07:54.921Z:WARNING:taskWebClient.c:834:Failed to setup WebClient -80
2025-11-02T10:07:56.648Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-02T10:08:13.058Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x7880)
2025-11-02T10:08:13.066Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-02T10:08:13.167Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-02T10:08:14.875Z:WARNING:taskWebClient.c:810:TLS handshake failed (-0x50) for fd=1
2025-11-02T10:08:14.882Z:WARNING:taskWebClient.c:834:Failed to setup WebClient -80
2025-11-02T10:08:26.636Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-02T10:08:28.648Z:USER:taskMaster.c:6684:Socket #1: L1N=235.8V L2N=234.3V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T10:08:57.062Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x7880)
2025-11-02T10:08:57.074Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-02T10:08:57.125Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-02T10:08:57.152Z:WARNING:taskWebClient.c:810:TLS handshake failed (-0x50) for fd=1
2025-11-02T10:08:57.160Z:WARNING:taskWebClient.c:834:Failed to setup WebClient -80
2025-11-02T10:09:07.074Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-02T10:09:23.058Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x7880)
2025-11-02T10:09:23.070Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-02T10:09:23.156Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-02T10:09:24.863Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-02T10:09:25.007Z:SECURITY:taskWebClient.c:446:Received unauthorized request, so removing client
2025-11-02T10:09:25.019Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-02T10:09:25.101Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-02T10:09:26.824Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-02T10:09:27.132Z:SECURITY:httpd_login.c:155:WebClient ha connected (account: admin)
2025-11-02T10:15:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T10:15:05.605Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 2.0)A Free:(17.0 14.0 14.0)A ALB:(17.0 14.6 14.0)A
2025-11-02T10:20:34.769Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-02T10:23:28.554Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=234.8V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T10:25:05.542Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(17.0 15.0 14.0)A ALB:(16.8 15.0 14.0)A
2025-11-02T10:30:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T10:35:05.480Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 1.0)A Free:(17.0 18.0 15.0)A ALB:(17.6 18.0 15.0)A
2025-11-02T10:35:35.175Z:USER:taskMaster.c:6582:Temperature: 25.0 C
2025-11-02T10:38:28.457Z:USER:taskMaster.c:6684:Socket #1: L1N=239.5V L2N=237.6V L3N=238.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T10:45:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T10:45:05.414Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.1 15.3 15.0)A
2025-11-02T10:50:35.480Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-02T10:53:28.363Z:USER:taskMaster.c:6684:Socket #1: L1N=236.7V L2N=236.5V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T10:55:05.351Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 16.5 15.0)A
2025-11-02T11:00:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T11:05:05.289Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 16.1 15.0)A
2025-11-02T11:05:35.933Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-02T11:08:28.316Z:USER:taskMaster.c:6684:Socket #1: L1N=236.4V L2N=235.7V L3N=236.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T11:15:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T11:15:05.226Z:INFO:active_lb.c:308:SMt:(6.0 -2.0 1.0)A Free:(10.0 18.0 15.0)A ALB:(17.2 17.8 15.0)A
2025-11-02T11:20:36.292Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-02T11:23:28.222Z:USER:taskMaster.c:6684:Socket #1: L1N=237.0V L2N=235.5V L3N=237.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T11:25:05.160Z:INFO:active_lb.c:308:SMt:(-2.0 -3.0 1.0)A Free:(18.0 19.0 15.0)A ALB:(18.0 19.0 15.0)A
2025-11-02T11:30:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T11:34:56.949Z:INFO:heap_trace.c:493:free: 56144/160768 (34.9%) min: 37040 (23.0%) alloc #: 229
2025-11-02T11:34:56.960Z:INFO:heap_trace.c:495:fragm: 27.0% 4K: 19.7% free blocks: # 13 largest: 40992
2025-11-02T11:35:05.097Z:INFO:active_lb.c:308:SMt:(-1.0 -3.0 1.0)A Free:(17.0 19.0 15.0)A ALB:(17.5 18.9 15.0)A
2025-11-02T11:35:36.695Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-02T11:38:28.128Z:USER:taskMaster.c:6684:Socket #1: L1N=236.0V L2N=235.3V L3N=236.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T11:45:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T11:45:05.035Z:INFO:active_lb.c:308:SMt:(-1.0 -3.0 1.0)A Free:(17.0 19.0 15.0)A ALB:(17.1 18.0 15.0)A
2025-11-02T11:50:37.101Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-02T11:53:28.031Z:USER:taskMaster.c:6684:Socket #1: L1N=235.3V L2N=234.3V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T11:55:04.972Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.8 17.6 15.0)A
2025-11-02T12:00:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T12:05:04.910Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-02T12:05:37.406Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-02T12:08:27.937Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=235.1V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T12:15:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T12:15:04.843Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 2.0)A Free:(15.0 17.0 14.0)A ALB:(15.4 16.6 14.0)A
2025-11-02T12:20:37.812Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-02T12:23:27.843Z:USER:taskMaster.c:6684:Socket #1: L1N=236.0V L2N=236.2V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T12:25:04.781Z:INFO:active_lb.c:308:SMt:(-2.0 1.0 1.0)A Free:(18.0 15.0 15.0)A ALB:(17.9 15.2 15.0)A
2025-11-02T12:30:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T12:35:04.718Z:INFO:active_lb.c:308:SMt:(-2.0 -1.0 1.0)A Free:(18.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-02T12:35:38.218Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-02T12:38:27.746Z:USER:taskMaster.c:6684:Socket #1: L1N=237.0V L2N=235.4V L3N=236.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T12:45:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T12:45:04.656Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 1.0)A Free:(17.0 14.0 15.0)A ALB:(16.7 14.3 15.0)A
2025-11-02T12:50:38.621Z:USER:taskMaster.c:6582:Temperature: 25.6 C
2025-11-02T12:53:27.652Z:USER:taskMaster.c:6684:Socket #1: L1N=235.7V L2N=235.8V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T12:55:04.593Z:INFO:active_lb.c:308:SMt:(-1.0 -3.0 1.0)A Free:(17.0 19.0 15.0)A ALB:(16.7 18.5 15.0)A
2025-11-02T13:00:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T13:05:04.527Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 10.0)A Free:(18.0 18.0 6.0)A ALB:(17.9 18.0 6.0)A
2025-11-02T13:05:39.023Z:USER:taskMaster.c:6582:Temperature: 26.0 C
2025-11-02T13:08:27.558Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.0V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T13:15:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T13:15:04.464Z:INFO:active_lb.c:308:SMt:(-2.0 -1.0 1.0)A Free:(18.0 17.0 15.0)A ALB:(18.0 16.5 15.0)A
2025-11-02T13:20:39.332Z:USER:taskMaster.c:6582:Temperature: 25.6 C
2025-11-02T13:23:27.460Z:USER:taskMaster.c:6684:Socket #1: L1N=235.1V L2N=235.3V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T13:25:04.402Z:INFO:active_lb.c:308:SMt:(1.0 -3.0 1.0)A Free:(15.0 19.0 15.0)A ALB:(15.1 17.8 15.0)A
2025-11-02T13:30:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T13:34:48.851Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-02T13:34:49.121Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-02T13:34:56.187Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-02T13:34:56.199Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-02T13:35:04.339Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 15.7 15.0)A
2025-11-02T13:35:39.734Z:USER:taskMaster.c:6582:Temperature: 25.6 C
2025-11-02T13:38:27.367Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=234.5V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T13:45:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T13:45:04.277Z:INFO:active_lb.c:308:SMt:(1.0 11.0 1.0)A Free:(15.0 5.0 15.0)A ALB:(16.2 7.2 15.0)A
2025-11-02T13:50:40.140Z:USER:taskMaster.c:6582:Temperature: 25.9 C
2025-11-02T13:53:27.273Z:USER:taskMaster.c:6684:Socket #1: L1N=231.9V L2N=232.3V L3N=232.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T13:55:04.210Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-02T14:00:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T14:05:04.148Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(17.0 14.0 15.0)A
2025-11-02T14:05:40.546Z:USER:taskMaster.c:6582:Temperature: 26.0 C
2025-11-02T14:08:27.179Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=234.3V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T14:15:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T14:15:04.085Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T14:20:40.949Z:USER:taskMaster.c:6582:Temperature: 26.1 C
2025-11-02T14:23:27.082Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=235.2V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T14:25:04.023Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(14.9 13.0 15.0)A
2025-11-02T14:30:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T14:35:03.960Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.4 13.7 14.5)A
2025-11-02T14:35:41.304Z:USER:taskMaster.c:6582:Temperature: 26.1 C
2025-11-02T14:38:27.039Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=234.2V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T14:45:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T14:45:03.894Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 12.9 15.0)A
2025-11-02T14:50:41.660Z:USER:taskMaster.c:6582:Temperature: 26.4 C
2025-11-02T14:53:26.941Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=233.1V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T14:55:03.832Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-02T15:00:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T15:05:03.769Z:INFO:active_lb.c:308:SMt:(7.0 3.0 1.0)A Free:(9.0 13.0 15.0)A ALB:(9.0 13.0 15.0)A
2025-11-02T15:05:42.066Z:USER:taskMaster.c:6582:Temperature: 26.2 C
2025-11-02T15:08:26.847Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=233.1V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T15:15:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T15:15:03.707Z:INFO:active_lb.c:308:SMt:(7.0 3.0 1.0)A Free:(9.0 13.0 15.0)A ALB:(9.0 13.0 15.0)A
2025-11-02T15:20:42.468Z:USER:taskMaster.c:6582:Temperature: 25.9 C
2025-11-02T15:23:26.753Z:USER:taskMaster.c:6684:Socket #1: L1N=230.3V L2N=231.0V L3N=230.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T15:25:03.644Z:INFO:active_lb.c:308:SMt:(10.0 3.0 1.0)A Free:(6.0 13.0 15.0)A ALB:(6.1 13.0 15.0)A
2025-11-02T15:30:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T15:34:55.429Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-02T15:34:55.441Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-02T15:35:03.578Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-02T15:35:42.824Z:USER:taskMaster.c:6582:Temperature: 26.1 C
2025-11-02T15:38:26.660Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=232.2V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T15:45:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T15:45:03.515Z:INFO:active_lb.c:308:SMt:(17.0 2.0 1.0)A Free:(-1.0 14.0 15.0)A ALB:(0.0 13.5 15.0)A
2025-11-02T15:50:43.179Z:USER:taskMaster.c:6582:Temperature: 25.6 C
2025-11-02T15:53:26.562Z:USER:taskMaster.c:6684:Socket #1: L1N=235.6V L2N=235.9V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T15:55:03.453Z:INFO:active_lb.c:308:SMt:(8.0 2.0 1.0)A Free:(8.0 14.0 15.0)A ALB:(8.0 14.0 15.0)A
2025-11-02T16:00:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T16:05:03.390Z:INFO:active_lb.c:308:SMt:(7.0 2.0 1.0)A Free:(9.0 14.0 15.0)A ALB:(9.4 14.0 15.0)A
2025-11-02T16:05:43.585Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-02T16:08:26.468Z:USER:taskMaster.c:6684:Socket #1: L1N=230.4V L2N=231.6V L3N=230.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T16:15:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T16:15:03.328Z:INFO:active_lb.c:308:SMt:(6.0 3.0 2.0)A Free:(10.0 13.0 14.0)A ALB:(10.1 12.7 14.0)A
2025-11-02T16:18:33.808Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-11-02T16:20:43.992Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-02T16:23:26.375Z:USER:taskMaster.c:6684:Socket #1: L1N=231.1V L2N=230.5V L3N=230.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T16:25:03.261Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(14.0 13.0 15.0)A ALB:(13.0 13.0 15.0)A
2025-11-02T16:28:33.746Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-11-02T16:30:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T16:35:03.199Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.0 13.4 15.0)A
2025-11-02T16:35:44.394Z:USER:taskMaster.c:6582:Temperature: 25.0 C
2025-11-02T16:38:26.277Z:USER:taskMaster.c:6684:Socket #1: L1N=229.9V L2N=229.1V L3N=228.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T16:38:33.781Z:INFO:taskLeds.c:338:Brightness set to 8%
2025-11-02T16:45:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T16:45:03.136Z:INFO:active_lb.c:308:SMt:(3.0 3.0 1.0)A Free:(13.0 13.0 15.0)A ALB:(13.2 13.0 15.0)A
2025-11-02T16:50:44.800Z:USER:taskMaster.c:6582:Temperature: 25.0 C
2025-11-02T16:53:26.183Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=231.0V L3N=231.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T16:55:03.074Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-02T17:00:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T17:05:03.011Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 14.1)A
2025-11-02T17:05:45.156Z:USER:taskMaster.c:6582:Temperature: 24.8 C
2025-11-02T17:08:26.089Z:USER:taskMaster.c:6684:Socket #1: L1N=231.4V L2N=231.3V L3N=230.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T17:15:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T17:15:02.945Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.6 13.8 15.0)A
2025-11-02T17:20:45.511Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-02T17:23:25.992Z:USER:taskMaster.c:6684:Socket #1: L1N=231.6V L2N=229.8V L3N=230.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T17:25:02.882Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T17:30:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T17:34:48.093Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-02T17:34:48.355Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-02T17:34:54.671Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-02T17:34:54.679Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-02T17:35:02.820Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.8 14.8 15.0)A
2025-11-02T17:35:45.917Z:USER:taskMaster.c:6582:Temperature: 24.5 C
2025-11-02T17:38:25.898Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=230.8V L3N=230.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T17:45:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T17:45:02.757Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.4 14.9 15.0)A
2025-11-02T17:50:46.320Z:USER:taskMaster.c:6582:Temperature: 24.8 C
2025-11-02T17:53:25.804Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=232.5V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T17:55:02.695Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.6 15.0 15.0)A
2025-11-02T18:00:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T18:05:02.628Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T18:05:46.726Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-02T18:08:25.710Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=232.9V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T18:15:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T18:15:02.566Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.1 14.0 15.0)A
2025-11-02T18:20:47.082Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-02T18:23:25.613Z:USER:taskMaster.c:6684:Socket #1: L1N=235.4V L2N=233.9V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T18:25:02.503Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.2 15.0)A
2025-11-02T18:30:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T18:35:02.441Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 13.9 15.0)A
2025-11-02T18:35:47.437Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-02T18:38:25.519Z:USER:taskMaster.c:6684:Socket #1: L1N=231.8V L2N=231.0V L3N=230.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T18:45:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T18:45:02.378Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.1 14.0 15.0)A
2025-11-02T18:50:47.839Z:USER:taskMaster.c:6582:Temperature: 24.1 C
2025-11-02T18:53:25.425Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=232.8V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T18:55:02.312Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.1 15.0 15.0)A
2025-11-02T19:00:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T19:05:02.250Z:INFO:active_lb.c:308:SMt:(5.0 1.0 2.0)A Free:(11.0 15.0 14.0)A ALB:(12.0 15.0 14.0)A
2025-11-02T19:05:48.246Z:USER:taskMaster.c:6582:Temperature: 24.1 C
2025-11-02T19:08:25.328Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=232.9V L3N=232.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T19:15:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T19:15:02.187Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-02T19:20:48.648Z:USER:taskMaster.c:6582:Temperature: 24.1 C
2025-11-02T19:23:25.234Z:USER:taskMaster.c:6684:Socket #1: L1N=234.9V L2N=234.7V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T19:25:02.125Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.2 15.0 15.0)A
2025-11-02T19:30:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T19:34:53.910Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-02T19:34:53.921Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-02T19:35:02.058Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.0 15.0 15.0)A
2025-11-02T19:35:48.957Z:USER:taskMaster.c:6582:Temperature: 24.1 C
2025-11-02T19:38:25.140Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=232.2V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T19:45:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T19:45:01.996Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T19:50:49.359Z:USER:taskMaster.c:6582:Temperature: 24.0 C
2025-11-02T19:53:25.042Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=232.7V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T19:55:01.933Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T20:00:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T20:05:01.871Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.9 15.0 15.0)A
2025-11-02T20:05:49.765Z:USER:taskMaster.c:6582:Temperature: 23.6 C
2025-11-02T20:08:24.949Z:USER:taskMaster.c:6684:Socket #1: L1N=235.4V L2N=234.6V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T20:15:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T20:15:01.804Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-02T20:20:50.167Z:USER:taskMaster.c:6582:Temperature: 23.6 C
2025-11-02T20:23:24.902Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=232.3V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T20:25:01.742Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 14.7)A
2025-11-02T20:30:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T20:35:01.679Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T20:35:50.574Z:USER:taskMaster.c:6582:Temperature: 23.5 C
2025-11-02T20:38:24.808Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=234.0V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T20:45:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T20:45:01.617Z:INFO:active_lb.c:308:SMt:(3.0 2.0 1.0)A Free:(13.0 14.0 15.0)A ALB:(13.2 14.0 15.0)A
2025-11-02T20:50:50.878Z:USER:taskMaster.c:6582:Temperature: 23.4 C
2025-11-02T20:53:24.714Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=231.8V L3N=231.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T20:55:01.550Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T21:00:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T21:05:01.488Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 14.9)A
2025-11-02T21:05:51.285Z:USER:taskMaster.c:6582:Temperature: 23.0 C
2025-11-02T21:08:24.617Z:USER:taskMaster.c:6684:Socket #1: L1N=235.3V L2N=234.5V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T21:15:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T21:15:01.425Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-02T21:20:51.687Z:USER:taskMaster.c:6582:Temperature: 23.0 C
2025-11-02T21:23:24.523Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=235.5V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T21:25:01.363Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 14.8)A
2025-11-02T21:30:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T21:34:46.312Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-02T21:34:46.578Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-02T21:34:53.148Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-02T21:34:53.160Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-02T21:35:01.296Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.0 14.0 14.6)A
2025-11-02T21:35:01.449Z:INFO:comFaults.c:482:Reset fault status
2025-11-02T21:35:52.093Z:USER:taskMaster.c:6582:Temperature: 22.9 C
2025-11-02T21:38:24.425Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=236.3V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T21:45:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T21:45:01.234Z:INFO:active_lb.c:308:SMt:(3.0 1.0 1.0)A Free:(13.0 15.0 15.0)A ALB:(13.6 14.6 15.0)A
2025-11-02T21:50:52.496Z:USER:taskMaster.c:6582:Temperature: 22.8 C
2025-11-02T21:53:24.332Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=236.3V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T21:55:01.171Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T22:00:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T22:05:01.109Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T22:05:52.800Z:USER:taskMaster.c:6582:Temperature: 22.5 C
2025-11-02T22:08:24.234Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=235.7V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T22:15:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T22:15:01.042Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T22:20:53.207Z:USER:taskMaster.c:6582:Temperature: 22.5 C
2025-11-02T22:23:24.140Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=235.9V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T22:25:00.980Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T22:30:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T22:35:00.917Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T22:35:53.613Z:USER:taskMaster.c:6582:Temperature: 22.4 C
2025-11-02T22:38:24.046Z:USER:taskMaster.c:6684:Socket #1: L1N=236.4V L2N=236.8V L3N=237.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T22:41:15.175Z:INFO:taskMaster.c:6376:Socket #1: no schedule
2025-11-02T22:41:15.183Z:USER:taskMaster.c:6402:Socket #1: external current limit 16.0 A
2025-11-02T22:45:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T22:45:00.851Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.6 15.0 15.0)A
2025-11-02T22:50:54.117Z:USER:taskMaster.c:6582:Temperature: 22.4 C
2025-11-02T22:53:23.949Z:USER:taskMaster.c:6684:Socket #1: L1N=233.3V L2N=234.1V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T22:55:00.789Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T23:00:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T23:05:00.726Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T23:05:54.519Z:USER:taskMaster.c:6582:Temperature: 22.1 C
2025-11-02T23:08:23.855Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=235.1V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T23:15:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T23:15:00.660Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T23:20:54.972Z:USER:taskMaster.c:6582:Temperature: 21.9 C
2025-11-02T23:23:23.757Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=235.2V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T23:25:00.597Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T23:30:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T23:34:52.382Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-02T23:34:52.394Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-02T23:35:00.535Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T23:35:54.878Z:USER:taskMaster.c:6582:Temperature: 22.0 C
2025-11-02T23:38:23.664Z:USER:taskMaster.c:6684:Socket #1: L1N=234.9V L2N=235.7V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T23:45:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-02T23:45:00.468Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-02T23:50:54.832Z:USER:taskMaster.c:6582:Temperature: 22.0 C
2025-11-02T23:53:23.566Z:USER:taskMaster.c:6684:Socket #1: L1N=235.4V L2N=236.0V L3N=235.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-02T23:55:00.406Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T00:00:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T00:05:00.343Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T00:05:55.238Z:USER:taskMaster.c:6582:Temperature: 21.5 C
2025-11-03T00:08:23.472Z:USER:taskMaster.c:6684:Socket #1: L1N=235.8V L2N=236.3V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T00:15:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T00:15:00.277Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T00:20:55.742Z:USER:taskMaster.c:6582:Temperature: 21.5 C
2025-11-03T00:23:23.375Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=236.7V L3N=236.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T00:25:00.214Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-03T00:30:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T00:35:00.152Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(14.9 14.0 15.0)A
2025-11-03T00:35:56.148Z:USER:taskMaster.c:6582:Temperature: 21.2 C
2025-11-03T00:38:23.281Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.3V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T00:45:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T00:45:00.085Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T00:50:56.597Z:USER:taskMaster.c:6582:Temperature: 21.2 C
2025-11-03T00:53:23.183Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=234.2V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T00:55:00.023Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T01:00:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T01:04:59.960Z:INFO:active_lb.c:308:SMt:(7.0 1.0 1.0)A Free:(9.0 15.0 15.0)A ALB:(9.5 15.0 15.0)A
2025-11-03T01:05:57.152Z:USER:taskMaster.c:6582:Temperature: 21.1 C
2025-11-03T01:08:23.085Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=233.8V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T01:14:59.894Z:INFO:active_lb.c:308:SMt:(7.0 1.0 1.0)A Free:(9.0 15.0 15.0)A ALB:(9.0 15.0 15.0)A
2025-11-03T01:15:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T01:20:57.507Z:USER:taskMaster.c:6582:Temperature: 21.2 C
2025-11-03T01:23:22.992Z:USER:taskMaster.c:6684:Socket #1: L1N=233.3V L2N=234.3V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T01:24:59.832Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(12.5 14.0 15.0)A
2025-11-03T01:30:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T01:34:44.582Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-03T01:34:44.847Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-03T01:34:51.617Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-03T01:34:51.628Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-03T01:34:59.765Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.1 14.0 15.0)A
2025-11-03T01:35:57.960Z:USER:taskMaster.c:6582:Temperature: 21.1 C
2025-11-03T01:38:22.894Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.3V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T01:44:59.703Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T01:45:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T01:50:58.367Z:USER:taskMaster.c:6582:Temperature: 20.9 C
2025-11-03T01:53:22.800Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=233.1V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T01:54:59.640Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T02:00:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T02:04:59.574Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-03T02:05:58.820Z:USER:taskMaster.c:6582:Temperature: 20.8 C
2025-11-03T02:08:22.703Z:USER:taskMaster.c:6684:Socket #1: L1N=235.6V L2N=235.8V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T02:14:59.511Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-03T02:15:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T02:20:59.222Z:USER:taskMaster.c:6582:Temperature: 20.8 C
2025-11-03T02:23:22.609Z:USER:taskMaster.c:6684:Socket #1: L1N=235.4V L2N=235.7V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T02:24:59.445Z:INFO:active_lb.c:308:SMt:(3.0 2.0 5.0)A Free:(13.0 14.0 11.0)A ALB:(13.6 14.0 11.0)A
2025-11-03T02:30:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T02:34:59.382Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(15.0 14.0 11.0)A ALB:(15.0 14.0 11.0)A
2025-11-03T02:35:59.675Z:USER:taskMaster.c:6582:Temperature: 20.6 C
2025-11-03T02:38:22.511Z:USER:taskMaster.c:6684:Socket #1: L1N=235.6V L2N=236.0V L3N=235.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T02:44:59.320Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-03T02:45:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T02:51:00.132Z:USER:taskMaster.c:6582:Temperature: 20.6 C
2025-11-03T02:53:22.414Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.2V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T02:54:59.253Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(14.4 15.0 11.0)A
2025-11-03T03:00:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T03:04:59.191Z:INFO:active_lb.c:308:SMt:(2.0 1.0 5.0)A Free:(14.0 15.0 11.0)A ALB:(14.2 15.0 11.0)A
2025-11-03T03:06:00.585Z:USER:taskMaster.c:6582:Temperature: 20.8 C
2025-11-03T03:08:22.320Z:USER:taskMaster.c:6684:Socket #1: L1N=233.4V L2N=233.7V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T03:14:59.125Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(14.0 15.0 11.0)A
2025-11-03T03:15:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T03:21:00.988Z:USER:taskMaster.c:6582:Temperature: 20.6 C
2025-11-03T03:23:22.222Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=233.3V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T03:24:59.062Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(15.0 14.0 11.0)A ALB:(15.0 14.0 11.0)A
2025-11-03T03:30:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T03:34:50.847Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-03T03:34:50.859Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-03T03:34:59.000Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(15.0 14.0 11.0)A ALB:(15.0 14.0 11.0)A
2025-11-03T03:36:01.441Z:USER:taskMaster.c:6582:Temperature: 20.5 C
2025-11-03T03:38:22.175Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=233.7V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T03:44:58.933Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-03T03:45:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T03:51:01.894Z:USER:taskMaster.c:6582:Temperature: 20.5 C
2025-11-03T03:53:22.082Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=236.3V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T03:54:58.871Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-03T04:00:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T04:04:58.804Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-03T04:06:01.902Z:USER:taskMaster.c:6582:Temperature: 20.2 C
2025-11-03T04:08:21.984Z:USER:taskMaster.c:6684:Socket #1: L1N=235.3V L2N=235.7V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T04:14:58.742Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-03T04:15:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T04:21:02.804Z:USER:taskMaster.c:6582:Temperature: 20.1 C
2025-11-03T04:23:21.886Z:USER:taskMaster.c:6684:Socket #1: L1N=236.9V L2N=237.4V L3N=237.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T04:24:58.679Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(15.0 14.0 11.0)A ALB:(15.0 14.0 11.0)A
2025-11-03T04:30:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T04:34:58.613Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(15.0 14.0 11.0)A ALB:(15.0 14.0 11.0)A
2025-11-03T04:36:03.207Z:USER:taskMaster.c:6582:Temperature: 20.1 C
2025-11-03T04:38:21.792Z:USER:taskMaster.c:6684:Socket #1: L1N=236.6V L2N=236.5V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T04:44:58.550Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-03T04:45:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T04:51:03.710Z:USER:taskMaster.c:6582:Temperature: 20.1 C
2025-11-03T04:53:21.695Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=234.6V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T04:54:58.484Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-03T05:00:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T05:04:58.421Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T05:06:04.113Z:USER:taskMaster.c:6582:Temperature: 20.0 C
2025-11-03T05:08:21.597Z:USER:taskMaster.c:6684:Socket #1: L1N=235.8V L2N=236.2V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T05:14:58.355Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T05:15:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T05:21:04.566Z:USER:taskMaster.c:6582:Temperature: 19.9 C
2025-11-03T05:23:21.503Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=234.2V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T05:24:58.292Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-03T05:30:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T05:34:42.886Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-03T05:34:43.152Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-03T05:34:50.078Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-03T05:34:50.089Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-03T05:34:58.226Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.0 14.0 14.4)A
2025-11-03T05:36:05.019Z:USER:taskMaster.c:6582:Temperature: 20.0 C
2025-11-03T05:38:21.406Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=234.7V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T05:44:58.164Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.0 15.0 15.0)A
2025-11-03T05:45:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T05:51:05.523Z:USER:taskMaster.c:6582:Temperature: 19.9 C
2025-11-03T05:53:21.308Z:USER:taskMaster.c:6684:Socket #1: L1N=231.6V L2N=232.0V L3N=231.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T05:54:58.097Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.6 15.0 15.0)A
2025-11-03T06:00:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T06:04:58.035Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.6 15.0 15.0)A
2025-11-03T06:06:05.976Z:USER:taskMaster.c:6582:Temperature: 19.8 C
2025-11-03T06:08:21.214Z:USER:taskMaster.c:6684:Socket #1: L1N=235.1V L2N=236.0V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T06:08:25.218Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-11-03T06:14:57.972Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T06:15:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T06:18:25.152Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-11-03T06:21:06.730Z:USER:taskMaster.c:6582:Temperature: 19.9 C
2025-11-03T06:23:21.117Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=232.9V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T06:24:57.906Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T06:28:25.187Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-11-03T06:30:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T06:34:57.843Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T06:36:06.882Z:USER:taskMaster.c:6582:Temperature: 19.9 C
2025-11-03T06:38:21.019Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=235.5V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T06:44:57.777Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T06:45:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T06:51:07.289Z:USER:taskMaster.c:6582:Temperature: 20.1 C
2025-11-03T06:53:20.925Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=233.2V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T06:54:57.714Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T07:00:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T07:04:57.648Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(14.4 15.0 14.0)A
2025-11-03T07:06:07.691Z:USER:taskMaster.c:6582:Temperature: 20.4 C
2025-11-03T07:08:20.828Z:USER:taskMaster.c:6684:Socket #1: L1N=235.4V L2N=235.7V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T07:14:57.585Z:INFO:active_lb.c:308:SMt:(7.0 1.0 1.0)A Free:(9.0 15.0 15.0)A ALB:(12.6 15.0 15.0)A
2025-11-03T07:15:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T07:21:08.144Z:USER:taskMaster.c:6582:Temperature: 20.2 C
2025-11-03T07:23:20.730Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=235.6V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T07:24:57.519Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.0 14.0 14.0)A
2025-11-03T07:30:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T07:34:49.304Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-03T07:34:49.316Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-03T07:34:57.457Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.0 14.0 14.0)A
2025-11-03T07:36:08.550Z:USER:taskMaster.c:6582:Temperature: 20.5 C
2025-11-03T07:38:20.636Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=236.0V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T07:44:57.394Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(15.0 15.0 14.0)A
2025-11-03T07:45:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T07:51:09.152Z:USER:taskMaster.c:6582:Temperature: 20.9 C
2025-11-03T07:53:20.539Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=237.4V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T07:54:57.378Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(17.0 15.0 14.0)A ALB:(17.0 15.0 14.0)A
2025-11-03T08:00:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T08:04:57.316Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(14.8 15.0 14.0)A
2025-11-03T08:06:09.457Z:USER:taskMaster.c:6582:Temperature: 21.2 C
2025-11-03T08:08:20.441Z:USER:taskMaster.c:6684:Socket #1: L1N=236.7V L2N=236.5V L3N=237.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T08:14:57.250Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(15.7 14.8 14.0)A
2025-11-03T08:15:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T08:21:09.910Z:USER:taskMaster.c:6582:Temperature: 21.8 C
2025-11-03T08:23:20.347Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=236.3V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T08:24:57.187Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(17.0 15.0 14.0)A ALB:(17.0 15.0 14.0)A
2025-11-03T08:30:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T08:34:57.121Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(17.0 15.0 14.0)A ALB:(16.8 15.0 14.0)A
2025-11-03T08:36:10.363Z:USER:taskMaster.c:6582:Temperature: 22.1 C
2025-11-03T08:38:20.250Z:USER:taskMaster.c:6684:Socket #1: L1N=235.3V L2N=236.0V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T08:44:57.058Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(17.0 15.0 14.0)A ALB:(17.0 15.0 14.0)A
2025-11-03T08:45:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T08:51:10.769Z:USER:taskMaster.c:6582:Temperature: 22.4 C
2025-11-03T08:53:20.156Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=235.3V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T08:54:56.996Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(15.2 15.0 14.0)A
2025-11-03T09:00:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T09:04:56.929Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(14.6 15.0 14.0)A
2025-11-03T09:06:11.175Z:USER:taskMaster.c:6582:Temperature: 22.5 C
2025-11-03T09:08:20.058Z:USER:taskMaster.c:6684:Socket #1: L1N=236.9V L2N=236.1V L3N=236.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T09:14:56.867Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(17.0 15.0 14.0)A ALB:(17.0 15.0 14.0)A
2025-11-03T09:15:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T09:21:11.679Z:USER:taskMaster.c:6582:Temperature: 22.4 C
2025-11-03T09:23:19.964Z:USER:taskMaster.c:6684:Socket #1: L1N=235.8V L2N=235.4V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T09:24:56.804Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(17.0 15.0 14.0)A ALB:(17.0 11.8 14.0)A
2025-11-03T09:30:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T09:34:42.230Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-03T09:34:42.496Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-03T09:34:48.539Z:INFO:heap_trace.c:493:free: 57152/160768 (35.5%) min: 37040 (23.0%) alloc #: 208
2025-11-03T09:34:48.550Z:INFO:heap_trace.c:495:fragm: 28.3% 4K: 14.0% free blocks: # 17 largest: 40992
2025-11-03T09:34:56.742Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(15.0 15.0 14.0)A
2025-11-03T09:34:56.839Z:INFO:comFaults.c:482:Reset fault status
2025-11-03T09:36:12.082Z:USER:taskMaster.c:6582:Temperature: 22.9 C
2025-11-03T09:38:19.867Z:USER:taskMaster.c:6684:Socket #1: L1N=236.4V L2N=237.2V L3N=236.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T09:44:56.675Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(15.0 15.0 14.0)A
2025-11-03T09:45:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T09:51:12.488Z:USER:taskMaster.c:6582:Temperature: 23.0 C
2025-11-03T09:53:19.773Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=237.0V L3N=237.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T09:54:56.613Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(17.0 15.0 14.0)A ALB:(17.0 15.0 14.0)A
2025-11-03T10:00:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T10:04:56.550Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(15.0 15.0 14.0)A
2025-11-03T10:06:13.339Z:USER:taskMaster.c:6582:Temperature: 23.1 C
2025-11-03T10:08:19.679Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=236.5V L3N=236.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T10:14:56.484Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(15.0 15.0 14.0)A
2025-11-03T10:15:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T10:21:13.394Z:USER:taskMaster.c:6582:Temperature: 23.2 C
2025-11-03T10:23:19.582Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.2V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T10:24:56.421Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(17.0 15.0 14.0)A ALB:(16.7 15.0 14.0)A
2025-11-03T10:30:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T10:34:56.359Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 2.0)A Free:(17.0 17.0 14.0)A ALB:(15.0 15.6 14.0)A
2025-11-03T10:36:13.800Z:USER:taskMaster.c:6582:Temperature: 23.5 C
2025-11-03T10:38:19.488Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=236.0V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T10:44:56.296Z:INFO:active_lb.c:308:SMt:(2.0 1.0 2.0)A Free:(14.0 15.0 14.0)A ALB:(14.5 15.0 14.0)A
2025-11-03T10:45:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T10:51:14.253Z:USER:taskMaster.c:6582:Temperature: 24.0 C
2025-11-03T10:53:19.390Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=233.8V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T10:54:56.230Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 2.0)A Free:(17.0 17.0 14.0)A ALB:(17.0 16.7 14.0)A
2025-11-03T11:00:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T11:04:56.167Z:INFO:active_lb.c:308:SMt:(-1.0 3.0 2.0)A Free:(17.0 13.0 14.0)A ALB:(17.0 13.4 14.0)A
2025-11-03T11:06:14.660Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-03T11:08:19.296Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=234.7V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T11:14:56.105Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 2.0)A Free:(17.0 14.0 14.0)A ALB:(17.0 14.0 14.0)A
2025-11-03T11:15:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T11:21:15.113Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-03T11:23:19.203Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=234.9V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T11:24:56.042Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 2.0)A Free:(17.0 14.0 14.0)A ALB:(16.3 14.0 14.0)A
2025-11-03T11:30:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T11:34:47.777Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-03T11:34:47.789Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-03T11:34:55.976Z:INFO:active_lb.c:308:SMt:(2.0 2.0 2.0)A Free:(14.0 14.0 14.0)A ALB:(14.3 14.0 14.0)A
2025-11-03T11:36:15.519Z:USER:taskMaster.c:6582:Temperature: 24.5 C
2025-11-03T11:38:19.105Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=237.3V L3N=236.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T11:44:55.914Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 2.0)A Free:(17.0 14.0 14.0)A ALB:(17.0 14.0 14.0)A
2025-11-03T11:45:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T11:51:15.925Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-03T11:53:19.011Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.8V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T11:54:55.851Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(17.0 15.0 14.0)A ALB:(17.0 14.0 14.0)A
2025-11-03T12:00:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T12:04:55.789Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 2.0)A Free:(17.0 14.0 14.0)A ALB:(17.0 14.0 14.0)A
2025-11-03T12:06:16.679Z:USER:taskMaster.c:6582:Temperature: 24.9 C
2025-11-03T12:08:18.917Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=233.8V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T12:14:55.722Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.7 13.6 14.0)A
2025-11-03T12:15:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T12:21:16.835Z:USER:taskMaster.c:6582:Temperature: 24.8 C
2025-11-03T12:23:18.820Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=236.2V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T12:24:55.660Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 2.0)A Free:(17.0 14.0 14.0)A ALB:(17.0 14.0 14.0)A
2025-11-03T12:30:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T12:34:55.597Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.2 14.0 14.0)A
2025-11-03T12:36:17.238Z:USER:taskMaster.c:6582:Temperature: 24.8 C
2025-11-03T12:38:18.726Z:USER:taskMaster.c:6684:Socket #1: L1N=235.8V L2N=237.0V L3N=236.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T12:44:55.535Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 2.0)A Free:(17.0 14.0 14.0)A ALB:(17.0 14.0 14.0)A
2025-11-03T12:45:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T12:51:17.695Z:USER:taskMaster.c:6582:Temperature: 25.0 C
2025-11-03T12:53:18.632Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=233.6V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T12:54:55.472Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 2.0)A Free:(17.0 14.0 14.0)A ALB:(17.0 14.0 14.0)A
2025-11-03T13:00:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T13:04:55.406Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.0 14.0 14.0)A
2025-11-03T13:06:18.148Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-03T13:08:18.535Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=233.8V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T13:14:55.343Z:INFO:active_lb.c:308:SMt:(-1.0 13.0 2.0)A Free:(17.0 3.0 14.0)A ALB:(17.0 3.9 14.0)A
2025-11-03T13:15:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T13:21:18.554Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-03T13:23:18.441Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.6V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T13:24:55.281Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 2.0)A Free:(17.0 14.0 14.0)A ALB:(17.0 14.0 14.0)A
2025-11-03T13:30:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T13:34:40.558Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-03T13:34:40.878Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-03T13:34:47.015Z:INFO:heap_trace.c:493:free: 54072/160768 (33.6%) min: 37040 (23.0%) alloc #: 209
2025-11-03T13:34:47.027Z:INFO:heap_trace.c:495:fragm: 24.2% 4K: 16.7% free blocks: # 18 largest: 40992
2025-11-03T13:34:55.218Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 2.0)A Free:(17.0 14.0 14.0)A ALB:(17.0 14.0 14.0)A
2025-11-03T13:36:18.957Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-03T13:38:18.347Z:USER:taskMaster.c:6684:Socket #1: L1N=233.2V L2N=233.5V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T13:44:55.156Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.2 13.9 14.0)A
2025-11-03T13:45:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T13:51:19.464Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-03T13:53:18.250Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=232.5V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T13:54:55.089Z:INFO:active_lb.c:308:SMt:(-1.0 3.0 2.0)A Free:(17.0 13.0 14.0)A ALB:(15.9 13.1 14.0)A
2025-11-03T14:00:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T14:04:55.027Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 2.0)A Free:(17.0 15.0 14.0)A ALB:(17.0 15.0 14.0)A
2025-11-03T14:06:19.820Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-03T14:08:18.156Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=233.6V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T14:14:54.964Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.0 14.0 14.0)A
2025-11-03T14:15:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T14:21:20.324Z:USER:taskMaster.c:6582:Temperature: 25.6 C
2025-11-03T14:23:18.062Z:USER:taskMaster.c:6684:Socket #1: L1N=231.3V L2N=231.8V L3N=231.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T14:24:54.902Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.0 13.1 14.0)A
2025-11-03T14:30:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T14:34:54.839Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 2.0)A Free:(17.0 14.0 14.0)A ALB:(16.7 14.0 14.0)A
2025-11-03T14:36:20.679Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-03T14:38:17.964Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=236.9V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T14:44:54.773Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(15.5 15.0 14.0)A
2025-11-03T14:45:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T14:51:21.132Z:USER:taskMaster.c:6582:Temperature: 25.6 C
2025-11-03T14:53:17.871Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=234.8V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T14:54:54.710Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(14.6 14.0 14.0)A
2025-11-03T15:00:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T15:04:54.648Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(15.0 15.0 14.0)A
2025-11-03T15:06:21.589Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-03T15:08:17.777Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=234.9V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T15:14:54.585Z:INFO:active_lb.c:308:SMt:(2.0 3.0 2.0)A Free:(14.0 13.0 14.0)A ALB:(14.2 13.0 14.0)A
2025-11-03T15:15:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T15:21:21.992Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-03T15:23:17.683Z:USER:taskMaster.c:6684:Socket #1: L1N=231.6V L2N=232.9V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T15:24:54.519Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.0 14.0 14.0)A
2025-11-03T15:30:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T15:34:46.257Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-03T15:34:46.269Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-03T15:34:54.457Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-11-03T15:36:22.398Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-03T15:38:17.585Z:USER:taskMaster.c:6684:Socket #1: L1N=237.6V L2N=237.8V L3N=237.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T15:44:54.394Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.0 13.8 14.0)A
2025-11-03T15:45:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T15:51:22.855Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-03T15:53:17.492Z:USER:taskMaster.c:6684:Socket #1: L1N=233.3V L2N=234.0V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T15:54:54.332Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-11-03T16:00:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T16:04:54.269Z:INFO:active_lb.c:308:SMt:(2.0 2.0 2.0)A Free:(14.0 14.0 14.0)A ALB:(14.3 12.9 14.0)A
2025-11-03T16:06:23.257Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-03T16:08:17.398Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=231.8V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T16:14:54.203Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-11-03T16:15:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T16:16:43.046Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-11-03T16:21:23.714Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-03T16:23:17.300Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=232.0V L3N=230.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T16:24:54.140Z:INFO:active_lb.c:308:SMt:(4.0 2.0 2.0)A Free:(12.0 14.0 14.0)A ALB:(12.0 14.0 14.0)A
2025-11-03T16:26:43.085Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-11-03T16:30:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T16:34:54.078Z:INFO:active_lb.c:308:SMt:(2.0 2.0 2.0)A Free:(14.0 14.0 14.0)A ALB:(14.0 14.0 14.4)A
2025-11-03T16:36:24.117Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-03T16:36:43.023Z:INFO:taskLeds.c:338:Brightness set to 8%
2025-11-03T16:38:17.207Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=233.0V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T16:44:54.015Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(14.0 13.0 15.0)A ALB:(14.0 12.4 15.0)A
2025-11-03T16:45:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T16:51:24.523Z:USER:taskMaster.c:6582:Temperature: 24.4 C
2025-11-03T16:53:17.113Z:USER:taskMaster.c:6684:Socket #1: L1N=230.0V L2N=229.1V L3N=229.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T16:54:53.953Z:INFO:active_lb.c:308:SMt:(3.0 4.0 2.0)A Free:(13.0 12.0 14.0)A ALB:(13.1 13.0 14.2)A
2025-11-03T17:00:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T17:04:53.886Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 13.0 14.6)A
2025-11-03T17:06:24.929Z:USER:taskMaster.c:6582:Temperature: 24.4 C
2025-11-03T17:08:17.015Z:USER:taskMaster.c:6684:Socket #1: L1N=231.7V L2N=231.8V L3N=231.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T17:14:53.824Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.5)A
2025-11-03T17:15:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T17:21:25.382Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-03T17:23:16.921Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=232.8V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T17:24:53.761Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.1)A
2025-11-03T17:30:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T17:34:38.890Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-03T17:34:39.156Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-03T17:34:45.500Z:INFO:heap_trace.c:493:free: 55952/160768 (34.8%) min: 37040 (23.0%) alloc #: 229
2025-11-03T17:34:45.507Z:INFO:heap_trace.c:495:fragm: 26.7% 4K: 19.5% free blocks: # 12 largest: 40992
2025-11-03T17:34:53.699Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 12.0 15.0)A
2025-11-03T17:36:25.890Z:USER:taskMaster.c:6582:Temperature: 24.1 C
2025-11-03T17:38:16.828Z:USER:taskMaster.c:6684:Socket #1: L1N=230.8V L2N=231.5V L3N=229.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T17:44:53.636Z:INFO:active_lb.c:308:SMt:(2.0 4.0 2.0)A Free:(14.0 12.0 14.0)A ALB:(14.1 12.4 14.0)A
2025-11-03T17:45:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T17:51:26.242Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-03T17:53:16.730Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=232.5V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T17:54:53.570Z:INFO:active_lb.c:308:SMt:(2.0 3.0 2.0)A Free:(14.0 13.0 14.0)A ALB:(14.4 12.9 14.0)A
2025-11-03T18:00:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T18:04:53.507Z:INFO:active_lb.c:308:SMt:(1.0 4.0 7.0)A Free:(15.0 12.0 9.0)A ALB:(15.0 12.0 9.0)A
2025-11-03T18:06:26.648Z:USER:taskMaster.c:6582:Temperature: 24.4 C
2025-11-03T18:08:16.636Z:USER:taskMaster.c:6684:Socket #1: L1N=230.9V L2N=230.9V L3N=228.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T18:14:53.445Z:INFO:active_lb.c:308:SMt:(1.0 4.0 7.0)A Free:(15.0 12.0 9.0)A ALB:(15.0 12.0 9.0)A
2025-11-03T18:15:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T18:21:27.101Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-03T18:23:16.542Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=231.8V L3N=231.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T18:24:53.382Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 12.0 15.0)A
2025-11-03T18:30:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T18:34:53.316Z:INFO:active_lb.c:308:SMt:(1.0 4.0 3.0)A Free:(15.0 12.0 13.0)A ALB:(15.0 12.0 13.0)A
2025-11-03T18:36:27.507Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-03T18:38:16.445Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=231.9V L3N=231.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T18:44:53.253Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(14.0 13.0 15.0)A ALB:(14.6 13.0 15.0)A
2025-11-03T18:45:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T18:51:27.414Z:USER:taskMaster.c:6582:Temperature: 24.4 C
2025-11-03T18:53:16.351Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=232.6V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T18:54:53.191Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 12.5 15.0)A
2025-11-03T19:00:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T19:04:53.128Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(14.0 13.0 15.0)A ALB:(14.1 13.0 15.0)A
2025-11-03T19:06:28.019Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-03T19:08:16.257Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=233.3V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T19:14:53.066Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 12.0 15.0)A
2025-11-03T19:15:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T19:21:28.875Z:USER:taskMaster.c:6582:Temperature: 24.4 C
2025-11-03T19:23:16.160Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.0V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T19:24:53.000Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 12.8 15.0)A
2025-11-03T19:30:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T19:34:44.738Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-03T19:34:44.750Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-03T19:34:52.937Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-03T19:36:29.277Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-03T19:38:16.066Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=234.7V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T19:44:52.875Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(14.0 13.0 15.0)A ALB:(14.1 13.0 15.0)A
2025-11-03T19:45:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T19:51:29.781Z:USER:taskMaster.c:6582:Temperature: 24.4 C
2025-11-03T19:53:15.972Z:USER:taskMaster.c:6684:Socket #1: L1N=235.1V L2N=235.0V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T19:54:52.812Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-03T20:00:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T20:04:52.746Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(14.9 12.0 15.0)A
2025-11-03T20:06:30.289Z:USER:taskMaster.c:6582:Temperature: 24.4 C
2025-11-03T20:08:15.875Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=231.6V L3N=230.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T20:14:52.683Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 12.0 15.0)A
2025-11-03T20:15:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T20:21:30.593Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-03T20:23:15.781Z:USER:taskMaster.c:6684:Socket #1: L1N=234.3V L2N=234.0V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T20:24:52.621Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-03T20:30:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T20:34:52.558Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-03T20:36:30.996Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-03T20:38:15.687Z:USER:taskMaster.c:6684:Socket #1: L1N=235.1V L2N=235.4V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T20:44:52.496Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-03T20:45:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T20:51:31.402Z:USER:taskMaster.c:6582:Temperature: 24.8 C
2025-11-03T20:53:15.593Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=232.5V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T20:54:52.429Z:INFO:active_lb.c:308:SMt:(2.0 4.0 1.0)A Free:(14.0 12.0 15.0)A ALB:(14.0 12.0 15.0)A
2025-11-03T21:00:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T21:04:52.367Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 12.0 15.0)A
2025-11-03T21:06:31.855Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-03T21:08:15.496Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=235.0V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T21:14:52.304Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-03T21:15:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T21:21:32.363Z:USER:taskMaster.c:6582:Temperature: 24.8 C
2025-11-03T21:23:15.402Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=235.3V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T21:24:52.242Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-03T21:30:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T21:34:37.214Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-03T21:34:37.484Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-03T21:34:43.976Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-03T21:34:43.988Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-03T21:34:52.175Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.4 14.0 15.0)A
2025-11-03T21:34:52.277Z:INFO:comFaults.c:482:Reset fault status
2025-11-03T21:36:32.718Z:USER:taskMaster.c:6582:Temperature: 24.9 C
2025-11-03T21:38:15.304Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.3V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T21:44:52.113Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-03T21:45:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T21:51:33.222Z:USER:taskMaster.c:6582:Temperature: 25.0 C
2025-11-03T21:53:15.210Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.2V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T21:54:52.050Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.9 15.0 15.0)A
2025-11-03T22:00:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T22:04:51.988Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.6 15.0 15.0)A
2025-11-03T22:06:33.828Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-03T22:08:15.117Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.0V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T22:14:51.925Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T22:15:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T22:21:33.980Z:USER:taskMaster.c:6582:Temperature: 25.0 C
2025-11-03T22:23:15.019Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=235.4V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T22:24:51.859Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T22:30:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T22:34:51.796Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T22:36:34.437Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-03T22:38:14.925Z:USER:taskMaster.c:6684:Socket #1: L1N=236.9V L2N=236.7V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T22:44:51.734Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.9 15.0 15.0)A
2025-11-03T22:45:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T22:51:34.992Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-03T22:53:14.832Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=234.7V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T22:54:51.671Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T23:00:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T23:04:51.605Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T23:06:35.246Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-03T23:08:14.734Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=234.5V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T23:14:51.542Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T23:15:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T23:21:35.652Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-03T23:23:14.640Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=235.4V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T23:24:51.480Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T23:30:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T23:34:43.214Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-03T23:34:43.226Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-03T23:34:51.417Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T23:36:36.105Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-03T23:38:14.546Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=235.5V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T23:44:51.355Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-03T23:45:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-03T23:51:36.562Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-03T23:53:14.449Z:USER:taskMaster.c:6684:Socket #1: L1N=233.2V L2N=233.5V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-03T23:54:51.289Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T00:00:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T00:04:51.226Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T00:06:36.964Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-04T00:08:14.355Z:USER:taskMaster.c:6684:Socket #1: L1N=237.0V L2N=237.4V L3N=237.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T00:14:51.164Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T00:15:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T00:21:37.421Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-04T00:23:14.261Z:USER:taskMaster.c:6684:Socket #1: L1N=237.5V L2N=237.9V L3N=237.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T00:24:51.101Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T00:30:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T00:34:51.035Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T00:36:37.824Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-04T00:38:14.164Z:USER:taskMaster.c:6684:Socket #1: L1N=234.3V L2N=234.9V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T00:44:50.972Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T00:45:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T00:51:37.980Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-04T00:53:14.070Z:USER:taskMaster.c:6684:Socket #1: L1N=235.6V L2N=235.7V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T00:54:50.910Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T01:00:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T01:04:50.847Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T01:06:38.687Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-04T01:08:13.976Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=235.1V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T01:14:50.785Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T01:15:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T01:21:38.742Z:USER:taskMaster.c:6582:Temperature: 25.0 C
2025-11-04T01:23:13.878Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=235.4V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T01:24:50.718Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T01:30:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T01:34:35.550Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-04T01:34:35.816Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-04T01:34:42.457Z:INFO:heap_trace.c:493:free: 55952/160768 (34.8%) min: 37040 (23.0%) alloc #: 229
2025-11-04T01:34:42.468Z:INFO:heap_trace.c:495:fragm: 26.7% 4K: 19.5% free blocks: # 12 largest: 40992
2025-11-04T01:34:50.656Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T01:36:38.746Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-04T01:38:13.785Z:USER:taskMaster.c:6684:Socket #1: L1N=235.6V L2N=236.0V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T01:44:50.593Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T01:45:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T01:51:38.902Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-04T01:53:13.691Z:USER:taskMaster.c:6684:Socket #1: L1N=236.0V L2N=236.1V L3N=235.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T01:54:50.531Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.1 15.0 15.0)A
2025-11-04T02:00:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T02:04:50.468Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-04T02:06:39.355Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-04T02:08:13.593Z:USER:taskMaster.c:6684:Socket #1: L1N=235.8V L2N=236.1V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T02:14:50.402Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-04T02:15:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T02:21:39.812Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-04T02:23:13.500Z:USER:taskMaster.c:6684:Socket #1: L1N=236.0V L2N=236.5V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T02:24:50.339Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-04T02:30:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T02:34:50.277Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-04T02:36:40.316Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-04T02:38:13.406Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=236.6V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T02:44:50.214Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-04T02:45:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T02:51:40.671Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-04T02:53:13.308Z:USER:taskMaster.c:6684:Socket #1: L1N=236.2V L2N=236.2V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T02:54:50.148Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-04T03:00:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T03:04:50.085Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-04T03:06:41.074Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-04T03:08:13.214Z:USER:taskMaster.c:6684:Socket #1: L1N=236.5V L2N=237.1V L3N=236.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T03:14:50.023Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-04T03:15:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T03:21:41.531Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-04T03:23:13.121Z:USER:taskMaster.c:6684:Socket #1: L1N=236.2V L2N=236.7V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T03:24:49.960Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-04T03:30:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T03:34:41.695Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-04T03:34:41.707Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-04T03:34:49.898Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-04T03:36:41.933Z:USER:taskMaster.c:6582:Temperature: 25.0 C
2025-11-04T03:38:13.027Z:USER:taskMaster.c:6684:Socket #1: L1N=235.7V L2N=236.0V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T03:44:49.832Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-04T03:45:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T03:51:42.339Z:USER:taskMaster.c:6582:Temperature: 25.0 C
2025-11-04T03:53:12.929Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=236.0V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T03:54:49.769Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-04T04:00:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T04:04:49.707Z:INFO:active_lb.c:308:SMt:(1.0 1.0 4.0)A Free:(15.0 15.0 12.0)A ALB:(15.0 15.0 11.3)A
2025-11-04T04:06:42.796Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-04T04:08:12.835Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.0V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T04:14:49.644Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-04T04:15:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T04:21:43.199Z:USER:taskMaster.c:6582:Temperature: 25.0 C
2025-11-04T04:23:12.742Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=233.9V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T04:24:49.582Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-04T04:30:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T04:34:49.515Z:INFO:active_lb.c:308:SMt:(1.0 1.0 4.0)A Free:(15.0 15.0 12.0)A ALB:(15.0 14.6 11.6)A
2025-11-04T04:36:43.656Z:USER:taskMaster.c:6582:Temperature: 24.9 C
2025-11-04T04:38:12.644Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=233.0V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T04:44:49.453Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-04T04:45:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T04:51:44.058Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-04T04:53:12.550Z:USER:taskMaster.c:6684:Socket #1: L1N=235.7V L2N=235.9V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T04:54:49.390Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-04T05:00:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T05:04:49.328Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T05:06:44.464Z:USER:taskMaster.c:6582:Temperature: 25.0 C
2025-11-04T05:08:12.457Z:USER:taskMaster.c:6684:Socket #1: L1N=236.5V L2N=236.8V L3N=237.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T05:14:49.261Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T05:15:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T05:21:44.871Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-04T05:23:12.359Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=235.3V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T05:24:49.199Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T05:30:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T05:34:34.890Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-04T05:34:35.160Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-04T05:34:40.937Z:INFO:heap_trace.c:493:free: 54072/160768 (33.6%) min: 37040 (23.0%) alloc #: 209
2025-11-04T05:34:40.945Z:INFO:heap_trace.c:495:fragm: 24.2% 4K: 16.7% free blocks: # 18 largest: 40992
2025-11-04T05:34:49.136Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T05:36:45.375Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-04T05:38:12.265Z:USER:taskMaster.c:6684:Socket #1: L1N=237.1V L2N=237.3V L3N=237.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T05:44:49.074Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T05:45:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T05:51:45.980Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-04T05:53:12.171Z:USER:taskMaster.c:6684:Socket #1: L1N=235.3V L2N=235.8V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T05:54:49.011Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 14.6)A
2025-11-04T06:00:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T06:04:48.996Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T06:06:46.183Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-04T06:08:12.074Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=235.7V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T06:10:14.765Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-11-04T06:14:48.933Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.9 15.0 15.0)A
2025-11-04T06:15:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T06:20:14.804Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-11-04T06:21:46.640Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-04T06:23:11.980Z:USER:taskMaster.c:6684:Socket #1: L1N=231.2V L2N=232.1V L3N=231.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T06:24:48.871Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.0 15.0 15.0)A
2025-11-04T06:30:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T06:30:14.839Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-11-04T06:34:48.804Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T06:36:47.042Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-04T06:38:11.886Z:USER:taskMaster.c:6684:Socket #1: L1N=232.0V L2N=233.0V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T06:44:48.742Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T06:45:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T06:51:47.148Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-04T06:53:11.789Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=236.0V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T06:54:48.679Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T07:00:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T07:04:48.617Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T07:06:47.953Z:USER:taskMaster.c:6582:Temperature: 25.6 C
2025-11-04T07:08:11.695Z:USER:taskMaster.c:6684:Socket #1: L1N=235.3V L2N=236.2V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T07:14:48.554Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T07:15:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T07:21:48.410Z:USER:taskMaster.c:6582:Temperature: 25.8 C
2025-11-04T07:23:11.601Z:USER:taskMaster.c:6684:Socket #1: L1N=235.1V L2N=235.8V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T07:24:48.488Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T07:30:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T07:34:40.175Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-04T07:34:40.187Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-04T07:34:48.425Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T07:36:48.812Z:USER:taskMaster.c:6582:Temperature: 25.8 C
2025-11-04T07:38:11.503Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=235.2V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T07:44:48.363Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T07:45:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T07:51:49.218Z:USER:taskMaster.c:6582:Temperature: 25.9 C
2025-11-04T07:53:11.410Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=236.1V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T07:54:48.300Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T08:00:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T08:04:48.238Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 1.0)A Free:(17.0 14.0 15.0)A ALB:(15.5 14.0 15.0)A
2025-11-04T08:06:49.675Z:USER:taskMaster.c:6582:Temperature: 25.9 C
2025-11-04T08:08:11.316Z:USER:taskMaster.c:6684:Socket #1: L1N=235.1V L2N=235.7V L3N=235.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T08:14:48.171Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.6 14.0 15.0)A
2025-11-04T08:15:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T08:21:50.078Z:USER:taskMaster.c:6582:Temperature: 26.2 C
2025-11-04T08:23:11.222Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=235.0V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T08:24:48.109Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T08:30:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T08:34:48.046Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(16.8 15.0 15.0)A
2025-11-04T08:36:50.535Z:USER:taskMaster.c:6582:Temperature: 26.2 C
2025-11-04T08:38:11.125Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=237.0V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T08:44:47.984Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.7 15.0 15.0)A
2025-11-04T08:45:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T08:51:50.937Z:USER:taskMaster.c:6582:Temperature: 26.4 C
2025-11-04T08:53:11.031Z:USER:taskMaster.c:6684:Socket #1: L1N=236.8V L2N=236.8V L3N=237.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T08:54:47.921Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-04T09:00:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T09:04:47.855Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-04T09:06:51.343Z:USER:taskMaster.c:6582:Temperature: 26.8 C
2025-11-04T09:08:10.933Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=235.9V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T09:14:47.792Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-04T09:15:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T09:21:51.750Z:USER:taskMaster.c:6582:Temperature: 27.0 C
2025-11-04T09:23:10.839Z:USER:taskMaster.c:6684:Socket #1: L1N=236.5V L2N=236.5V L3N=235.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T09:24:47.730Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-04T09:30:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T09:34:33.246Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-04T09:34:33.511Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-04T09:34:39.417Z:INFO:heap_trace.c:493:free: 56640/160768 (35.2%) min: 37040 (23.0%) alloc #: 220
2025-11-04T09:34:39.425Z:INFO:heap_trace.c:495:fragm: 27.6% 4K: 20.5% free blocks: # 18 largest: 40992
2025-11-04T09:34:47.667Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-04T09:34:47.718Z:INFO:comFaults.c:482:Reset fault status
2025-11-04T09:36:52.203Z:USER:taskMaster.c:6582:Temperature: 27.0 C
2025-11-04T09:38:10.746Z:USER:taskMaster.c:6684:Socket #1: L1N=238.3V L2N=237.5V L3N=237.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T09:44:47.605Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-04T09:45:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T09:51:52.660Z:USER:taskMaster.c:6582:Temperature: 27.1 C
2025-11-04T09:53:10.652Z:USER:taskMaster.c:6684:Socket #1: L1N=237.5V L2N=237.9V L3N=236.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T09:54:47.539Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-04T10:00:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T10:04:47.476Z:INFO:active_lb.c:308:SMt:(2.0 -1.0 1.0)A Free:(14.0 17.0 15.0)A ALB:(14.7 17.0 15.0)A
2025-11-04T10:06:53.062Z:USER:taskMaster.c:6582:Temperature: 27.5 C
2025-11-04T10:08:10.554Z:USER:taskMaster.c:6684:Socket #1: L1N=235.7V L2N=236.1V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T10:14:47.414Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-04T10:15:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T10:21:53.468Z:USER:taskMaster.c:6582:Temperature: 27.6 C
2025-11-04T10:23:10.460Z:USER:taskMaster.c:6684:Socket #1: L1N=238.4V L2N=238.6V L3N=238.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T10:24:47.351Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-04T10:30:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T10:34:47.289Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 1.0)A Free:(17.0 18.0 15.0)A ALB:(15.4 17.1 15.0)A
2025-11-04T10:36:53.925Z:USER:taskMaster.c:6582:Temperature: 27.6 C
2025-11-04T10:38:10.367Z:USER:taskMaster.c:6684:Socket #1: L1N=236.5V L2N=236.9V L3N=236.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T10:44:47.222Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(18.0 18.0 15.0)A ALB:(18.0 19.0 15.0)A
2025-11-04T10:45:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T10:51:54.328Z:USER:taskMaster.c:6582:Temperature: 27.6 C
2025-11-04T10:53:10.269Z:USER:taskMaster.c:6684:Socket #1: L1N=237.8V L2N=237.6V L3N=238.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T10:54:47.160Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(18.0 18.0 15.0)A ALB:(18.0 18.0 15.0)A
2025-11-04T11:00:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T11:04:47.097Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(18.0 18.0 15.0)A ALB:(17.6 18.0 15.0)A
2025-11-04T11:06:54.734Z:USER:taskMaster.c:6582:Temperature: 27.8 C
2025-11-04T11:08:10.175Z:USER:taskMaster.c:6684:Socket #1: L1N=235.6V L2N=235.9V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T11:14:47.035Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 1.0)A Free:(17.0 18.0 15.0)A ALB:(17.4 17.4 15.0)A
2025-11-04T11:15:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T11:21:55.187Z:USER:taskMaster.c:6582:Temperature: 27.6 C
2025-11-04T11:23:10.082Z:USER:taskMaster.c:6684:Socket #1: L1N=235.1V L2N=235.4V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T11:24:46.972Z:INFO:active_lb.c:308:SMt:(-2.0 -3.0 1.0)A Free:(18.0 19.0 15.0)A ALB:(17.9 18.7 15.0)A
2025-11-04T11:30:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T11:34:38.656Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-04T11:34:38.667Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-04T11:34:46.906Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(18.0 18.0 15.0)A ALB:(18.0 18.5 15.0)A
2025-11-04T11:36:55.593Z:USER:taskMaster.c:6582:Temperature: 27.9 C
2025-11-04T11:38:09.984Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=235.2V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T11:44:46.843Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.3 17.4 15.0)A
2025-11-04T11:45:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T11:51:55.550Z:USER:taskMaster.c:6582:Temperature: 27.8 C
2025-11-04T11:53:09.890Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=235.3V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T11:54:46.781Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(18.0 18.0 15.0)A ALB:(17.9 18.0 15.0)A
2025-11-04T12:00:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T12:04:46.718Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(18.0 18.0 15.0)A ALB:(17.4 16.7 15.0)A
2025-11-04T12:06:55.453Z:USER:taskMaster.c:6582:Temperature: 28.0 C
2025-11-04T12:08:09.796Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=234.1V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T12:14:46.656Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 1.0)A Free:(17.0 18.0 15.0)A ALB:(17.0 17.3 15.0)A
2025-11-04T12:15:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T12:21:55.859Z:USER:taskMaster.c:6582:Temperature: 28.0 C
2025-11-04T12:23:09.703Z:USER:taskMaster.c:6684:Socket #1: L1N=237.7V L2N=238.8V L3N=238.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T12:24:46.589Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(18.0 18.0 15.0)A ALB:(18.0 18.0 15.0)A
2025-11-04T12:30:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T12:34:46.527Z:INFO:active_lb.c:308:SMt:(6.0 1.0 1.0)A Free:(10.0 15.0 15.0)A ALB:(10.0 15.1 15.0)A
2025-11-04T12:36:56.316Z:USER:taskMaster.c:6582:Temperature: 28.2 C
2025-11-04T12:38:09.605Z:USER:taskMaster.c:6684:Socket #1: L1N=236.7V L2N=238.3V L3N=237.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T12:44:46.464Z:INFO:active_lb.c:308:SMt:(7.0 -1.0 1.0)A Free:(9.0 17.0 15.0)A ALB:(9.4 17.0 15.0)A
2025-11-04T12:45:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T12:51:56.718Z:USER:taskMaster.c:6582:Temperature: 28.1 C
2025-11-04T12:53:09.511Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=234.1V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T12:54:46.402Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-04T13:00:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T13:04:46.339Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(16.9 15.0 15.0)A
2025-11-04T13:06:57.125Z:USER:taskMaster.c:6582:Temperature: 28.1 C
2025-11-04T13:08:09.417Z:USER:taskMaster.c:6684:Socket #1: L1N=235.1V L2N=235.6V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T13:14:46.273Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-04T13:15:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T13:21:57.828Z:USER:taskMaster.c:6582:Temperature: 28.1 C
2025-11-04T13:23:09.320Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=235.1V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T13:24:46.210Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-04T13:30:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T13:34:31.597Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-04T13:34:31.867Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-04T13:34:37.898Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-04T13:34:37.910Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-04T13:34:46.148Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-04T13:36:58.035Z:USER:taskMaster.c:6582:Temperature: 28.2 C
2025-11-04T13:38:09.226Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.3V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T13:44:46.085Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-04T13:45:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T13:51:58.437Z:USER:taskMaster.c:6582:Temperature: 28.2 C
2025-11-04T13:53:09.132Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=234.4V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T13:54:46.023Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-04T14:00:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T14:04:45.957Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T14:06:58.843Z:USER:taskMaster.c:6582:Temperature: 28.4 C
2025-11-04T14:08:09.035Z:USER:taskMaster.c:6684:Socket #1: L1N=233.3V L2N=233.9V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T14:14:45.894Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-04T14:15:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T14:21:59.250Z:USER:taskMaster.c:6582:Temperature: 28.6 C
2025-11-04T14:23:08.941Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=235.1V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T14:24:45.832Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.3 15.0 15.0)A
2025-11-04T14:30:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T14:34:45.769Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T14:36:59.656Z:USER:taskMaster.c:6582:Temperature: 28.4 C
2025-11-04T14:38:08.847Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=233.7V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T14:44:45.707Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.3 15.0 15.0)A
2025-11-04T14:45:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T14:52:00.308Z:USER:taskMaster.c:6582:Temperature: 28.4 C
2025-11-04T14:53:08.753Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=235.9V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T14:54:45.640Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T15:00:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T15:04:45.578Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(16.3 15.0 15.0)A
2025-11-04T15:07:00.714Z:USER:taskMaster.c:6582:Temperature: 28.1 C
2025-11-04T15:08:08.656Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=234.2V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T15:14:45.515Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T15:15:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T15:22:01.070Z:USER:taskMaster.c:6582:Temperature: 28.0 C
2025-11-04T15:23:08.562Z:USER:taskMaster.c:6684:Socket #1: L1N=236.2V L2N=236.0V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T15:24:45.453Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T15:30:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T15:34:37.136Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-04T15:34:37.148Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-04T15:34:45.390Z:INFO:active_lb.c:308:SMt:(3.0 1.0 1.0)A Free:(13.0 15.0 15.0)A ALB:(13.4 15.0 15.0)A
2025-11-04T15:37:01.476Z:USER:taskMaster.c:6582:Temperature: 27.9 C
2025-11-04T15:38:08.468Z:USER:taskMaster.c:6684:Socket #1: L1N=232.0V L2N=232.5V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T15:44:45.324Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T15:45:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T15:52:01.929Z:USER:taskMaster.c:6582:Temperature: 27.9 C
2025-11-04T15:53:08.371Z:USER:taskMaster.c:6684:Socket #1: L1N=231.0V L2N=231.0V L3N=230.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T15:54:45.261Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T16:00:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T16:04:45.199Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T16:05:09.613Z:INFO:taskMain.c:5996:Socket #1: Active current 0.0->15.0 due to current limit: Active-LoadBalancing
2025-11-04T16:05:09.648Z:INFO:taskMaster.c:4957:Socket #1: state main : CABLE_CONNECTED
2025-11-04T16:05:09.656Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_A
2025-11-04T16:05:09.664Z:INFO:taskMaster.c:4979:Socket #1: state led : CABLE_CONNECTED
2025-11-04T16:05:10.171Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-04T16:05:10.179Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-04T16:05:10.187Z:INFO:taskMain.c:6504:Socket #1: PP 697 Ohm (20 A)
2025-11-04T16:05:10.195Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.9% (14.9 A)
2025-11-04T16:05:10.691Z:INFO:taskMain.c:1419:Socket #1: main state: CABLE_CONNECTED, CP: 9.3/0.9, no tag
2025-11-04T16:05:11.695Z:INFO:taskMaster.c:4957:Socket #1: state main : EV_CONNECTED_UNAUTHORIZED
2025-11-04T16:05:11.707Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-04T16:05:12.691Z:INFO:taskMain.c:1419:Socket #1: main state: EV_CONNECTED_UNAUTHORIZED, CP: 9.3/0.9, no tag
2025-11-04T16:05:13.996Z:USER:tag.c:1623:Reader 0 Got NFC tag: 04BB29EAFD0F94
2025-11-04T16:05:14.195Z:USER:taskMaster.c:6931:Socket #1: has reliable metervalue
2025-11-04T16:05:14.203Z:INFO:taskMaster.c:1604:1 cables attached
2025-11-04T16:05:14.246Z:INFO:taskMaster.c:4979:Socket #1: state led : AUTHORISING
2025-11-04T16:05:14.261Z:USER:tag.c:584:Tag 04BB29EAFD0F94 is authorised by white list
2025-11-04T16:05:14.296Z:USER:taskMaster.c:1914:Multiple cables attached, prioritizing socket #1
2025-11-04T16:05:14.343Z:USER:board_ng9xx.c:5068:Socket #1: lock socket motor
2025-11-04T16:05:14.351Z:INFO:taskMaster.c:4957:Socket #1: state main : EV_CONNECTED_AUTHORIZED
2025-11-04T16:05:15.351Z:INFO:taskMain.c:1417:Socket #1: main state: EV_CONNECTED_AUTHORIZED, CP: 9.2/9.3, tag: 04BB29EAFD0F94
2025-11-04T16:05:15.363Z:INFO:taskMaster.c:7497:New charging session started, metervalue=5609258.000
2025-11-04T16:05:15.378Z:INFO:db_transaction.c:16:Added TransactionStart for socket 1 at 0x0000b49c (ts: 2025-11-04 16:05:14)
2025-11-04T16:05:15.402Z:INFO:taskMaster.c:4979:Socket #1: state led : EV_CONNECTED
2025-11-04T16:05:15.410Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:05:15.441Z:INFO:taskMain.c:938:Socket #1: charging session status set active
2025-11-04T16:05:15.472Z:INFO:taskMaster.c:6353:Socket #1: external current limit 15.9 A until 2025-11-04T23:00:00Z
2025-11-04T16:05:15.488Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-04T16:05:15.496Z:INFO:db_chargingprofi:26: socket 0
2025-11-04T16:05:15.503Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-04T16:05:15.511Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-04T16:05:15.519Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-04T16:05:15.531Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-04T16:05:15.539Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-04T16:05:15.550Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-04T16:05:15.558Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-04T16:05:15.566Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-04T16:05:15.574Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-04T16:05:15.582Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-04T16:05:15.589Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-04T16:05:15.597Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-04T16:05:15.605Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-04T16:05:15.613Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-04T16:05:15.621Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-04T16:05:15.632Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-04T16:05:15.640Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-04T16:05:15.648Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-04T16:05:15.656Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-04T16:05:15.664Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-04T16:05:15.671Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-04T16:05:15.726Z:USER:taskMaster.c:6402:Socket #1: external current limit 15.9 A
2025-11-04T16:05:15.738Z:INFO:taskMaster.c:4957:Socket #1: state main : WAIT_FOR_START_METERVALUE
2025-11-04T16:05:15.746Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_PREPARING
2025-11-04T16:05:16.550Z:INFO:taskMain.c:1417:Socket #1: main state: WAIT_FOR_START_METERVALUE, CP: 9.3/9.3, tag: 04BB29EAFD0F
2025-11-04T16:05:16.550Z:INFO:taskMain.c:1417:94
2025-11-04T16:05:18.496Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-04T16:05:18.503Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-04T16:05:18.546Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-04T16:05:18.570Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-04T16:05:19.496Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-04T16:05:19.503Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-04T16:05:19.515Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=231.9V L3N=231.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T16:05:19.527Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T16:05:19.535Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-04T16:05:19.546Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-04T16:05:19.554Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-04T16:05:19.582Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-04T16:05:20.480Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-04T16:05:29.585Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-04T16:05:29.593Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-04T16:05:29.605Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-04T16:05:29.613Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-04T16:05:29.621Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-04T16:05:30.589Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-04T16:05:43.300Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->11.4 due to current limit: Active-LoadBalancing
2025-11-04T16:05:43.718Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.9% (11.3 A)
2025-11-04T16:05:49.542Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=231.8V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T16:05:49.554Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T16:05:55.296Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->12.8 due to current limit: Active-LoadBalancing
2025-11-04T16:05:55.839Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.3% (12.8 A)
2025-11-04T16:05:59.589Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-04T16:05:59.601Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-04T16:05:59.878Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-04T16:05:59.886Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-04T16:06:00.597Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-04T16:06:03.589Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-04T16:06:03.628Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-04T16:06:03.632Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-04T16:06:04.089Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-04T16:06:04.101Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-04T16:06:04.636Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-04T16:06:05.125Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-04T16:06:07.296Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->13.7 due to current limit: Active-LoadBalancing
2025-11-04T16:06:08.156Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.8% (13.7 A)
2025-11-04T16:06:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:06:19.296Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->14.2 due to current limit: Active-LoadBalancing
2025-11-04T16:06:19.464Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-04T16:06:19.539Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=231.1V L3N=231.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T16:06:19.550Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T16:06:20.273Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.7% (14.2 A)
2025-11-04T16:06:31.292Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-04T16:06:43.292Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-04T16:06:49.535Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=231.1V L3N=231.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T16:06:49.546Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T16:06:55.292Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-04T16:07:01.984Z:USER:taskMaster.c:6582:Temperature: 27.6 C
2025-11-04T16:07:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:07:19.289Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T16:07:19.531Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=231.2V L3N=231.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T16:07:19.546Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T16:07:49.531Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=231.1V L3N=230.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T16:07:49.546Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T16:08:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:08:19.527Z:USER:taskMaster.c:6684:Socket #1: L1N=232.0V L2N=231.1V L3N=231.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T16:08:19.539Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T16:08:49.523Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=231.2V L3N=231.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T16:08:49.535Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T16:09:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:09:19.519Z:USER:taskMaster.c:6684:Socket #1: L1N=230.9V L2N=230.6V L3N=230.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T16:09:19.531Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T16:09:49.515Z:USER:taskMaster.c:6684:Socket #1: L1N=231.5V L2N=230.7V L3N=230.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T16:09:49.531Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T16:10:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:10:19.515Z:USER:taskMaster.c:6684:Socket #1: L1N=231.8V L2N=231.3V L3N=230.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T16:10:19.527Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T16:10:19.535Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-04T16:11:07.265Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-04T16:11:08.093Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-04T16:11:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:11:19.265Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-04T16:11:31.261Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-04T16:11:55.261Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-04T16:12:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:12:31.257Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-04T16:12:31.917Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-04T16:12:43.253Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-04T16:12:55.253Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-04T16:13:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:13:19.250Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T16:14:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:14:43.242Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->11.4 due to current limit: Active-LoadBalancing
2025-11-04T16:14:44.210Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.0% (11.4 A)
2025-11-04T16:14:45.136Z:INFO:active_lb.c:308:SMt:(1.0 1.0 10.0)A Free:(15.0 15.0 6.0)A ALB:(15.0 15.0 11.4)A
2025-11-04T16:14:54.039Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-11-04T16:14:55.242Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->9.2 due to current limit: Active-LoadBalancing
2025-11-04T16:14:55.320Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.4% (9.2 A)
2025-11-04T16:15:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T16:15:07.238Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->7.9 due to current limit: Active-LoadBalancing
2025-11-04T16:15:07.441Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.2% (7.9 A)
2025-11-04T16:15:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:15:19.238Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->7.2 due to current limit: Active-LoadBalancing
2025-11-04T16:15:19.558Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.9% (7.1 A)
2025-11-04T16:15:31.238Z:INFO:taskMain.c:5996:Socket #1: Active current 7.2->6.7 due to current limit: Active-LoadBalancing
2025-11-04T16:15:31.675Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.1% (6.7 A)
2025-11-04T16:15:43.234Z:INFO:taskMain.c:5996:Socket #1: Active current 6.7->10.0 due to current limit: Active-LoadBalancing
2025-11-04T16:15:43.796Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.6% (10.0 A)
2025-11-04T16:15:55.234Z:INFO:taskMain.c:5996:Socket #1: Active current 10.0->8.4 due to current limit: Active-LoadBalancing
2025-11-04T16:15:55.914Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.0% (8.4 A)
2025-11-04T16:16:07.234Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->9.4 due to current limit: Active-LoadBalancing
2025-11-04T16:16:08.035Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.7% (9.4 A)
2025-11-04T16:16:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:16:19.230Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->11.7 due to current limit: Active-LoadBalancing
2025-11-04T16:16:20.152Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.4% (11.6 A)
2025-11-04T16:16:31.230Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->9.4 due to current limit: Active-LoadBalancing
2025-11-04T16:16:31.261Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.6% (9.4 A)
2025-11-04T16:16:43.230Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->8.0 due to current limit: Active-LoadBalancing
2025-11-04T16:16:43.378Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.4% (8.0 A)
2025-11-04T16:16:55.226Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->7.2 due to current limit: Active-LoadBalancing
2025-11-04T16:16:55.500Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.0% (7.2 A)
2025-11-04T16:17:07.226Z:INFO:taskMain.c:5996:Socket #1: Active current 7.2->6.7 due to current limit: Active-LoadBalancing
2025-11-04T16:17:07.617Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.2% (6.7 A)
2025-11-04T16:17:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:17:19.226Z:INFO:taskMain.c:5996:Socket #1: Active current 6.7->6.4 due to current limit: Active-LoadBalancing
2025-11-04T16:17:31.226Z:INFO:taskMain.c:5996:Socket #1: Active current 6.4->9.9 due to current limit: Active-LoadBalancing
2025-11-04T16:17:31.855Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.4% (9.8 A)
2025-11-04T16:17:43.222Z:INFO:taskMain.c:5996:Socket #1: Active current 9.9->11.9 due to current limit: Active-LoadBalancing
2025-11-04T16:17:43.972Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.8% (11.9 A)
2025-11-04T16:17:55.222Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->13.2 due to current limit: Active-LoadBalancing
2025-11-04T16:17:56.093Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.9% (13.1 A)
2025-11-04T16:18:07.222Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->10.3 due to current limit: Active-LoadBalancing
2025-11-04T16:18:08.210Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.1% (10.3 A)
2025-11-04T16:18:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:18:19.218Z:INFO:taskMain.c:5996:Socket #1: Active current 10.3->12.2 due to current limit: Active-LoadBalancing
2025-11-04T16:18:19.320Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.2% (12.1 A)
2025-11-04T16:18:31.218Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->9.7 due to current limit: Active-LoadBalancing
2025-11-04T16:18:31.437Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.1% (9.7 A)
2025-11-04T16:18:43.218Z:INFO:taskMain.c:5996:Socket #1: Active current 9.7->8.2 due to current limit: Active-LoadBalancing
2025-11-04T16:18:43.558Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.7% (8.2 A)
2025-11-04T16:18:55.214Z:INFO:taskMain.c:5996:Socket #1: Active current 8.2->10.9 due to current limit: Active-LoadBalancing
2025-11-04T16:18:55.675Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.2% (10.9 A)
2025-11-04T16:19:07.214Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->9.0 due to current limit: Active-LoadBalancing
2025-11-04T16:19:07.792Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.9% (8.9 A)
2025-11-04T16:19:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:19:19.214Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->7.8 due to current limit: Active-LoadBalancing
2025-11-04T16:19:19.914Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.9% (7.7 A)
2025-11-04T16:19:31.210Z:INFO:taskMain.c:5996:Socket #1: Active current 7.8->10.7 due to current limit: Active-LoadBalancing
2025-11-04T16:19:32.031Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.7% (10.6 A)
2025-11-04T16:19:43.210Z:INFO:taskMain.c:5996:Socket #1: Active current 10.7->8.8 due to current limit: Active-LoadBalancing
2025-11-04T16:19:44.152Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.6% (8.8 A)
2025-11-04T16:19:55.210Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->11.3 due to current limit: Active-LoadBalancing
2025-11-04T16:19:55.257Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.7% (11.2 A)
2025-11-04T16:20:07.207Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->12.8 due to current limit: Active-LoadBalancing
2025-11-04T16:20:07.378Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.2% (12.7 A)
2025-11-04T16:20:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:20:19.207Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->13.7 due to current limit: Active-LoadBalancing
2025-11-04T16:20:19.496Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.7% (13.6 A)
2025-11-04T16:20:31.207Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->14.2 due to current limit: Active-LoadBalancing
2025-11-04T16:20:31.617Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.6% (14.2 A)
2025-11-04T16:20:43.203Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-04T16:20:55.203Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-04T16:21:07.203Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-04T16:21:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:21:19.199Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-04T16:21:31.199Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.3 due to current limit: Active-LoadBalancing
2025-11-04T16:21:43.199Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-04T16:21:55.195Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-04T16:22:02.390Z:USER:taskMaster.c:6582:Temperature: 27.8 C
2025-11-04T16:22:07.195Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-04T16:22:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:22:19.195Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-04T16:22:43.191Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T16:23:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:24:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:24:45.074Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T16:24:54.078Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-11-04T16:25:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:25:19.417Z:USER:taskMaster.c:6684:Socket #1: L1N=233.2V L2N=234.6V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T16:25:19.429Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T16:26:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:27:07.164Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->9.4 due to current limit: Active-LoadBalancing
2025-11-04T16:27:07.492Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.6% (9.4 A)
2025-11-04T16:27:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:27:19.164Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->6.0 due to current limit: Active-LoadBalancing
2025-11-04T16:27:19.613Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.0% (6.0 A)
2025-11-04T16:27:31.160Z:INFO:taskMain.c:5996:Socket #1: Active current 6.0->4.0 due to current limit: Active-LoadBalancing
2025-11-04T16:27:31.175Z:WARNING:taskMain.c:4698:Socket #1: maximum current(4.02) < minimum current(6.00)
2025-11-04T16:27:31.207Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-04T16:27:31.214Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-04T16:27:31.226Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-04T16:27:31.730Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-04T16:27:32.199Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-11-04T16:27:32.199Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-04T16:27:43.160Z:INFO:taskMain.c:5996:Socket #1: Active current 4.0->2.8 due to current limit: Active-LoadBalancing
2025-11-04T16:27:55.160Z:INFO:taskMain.c:5996:Socket #1: Active current 2.8->2.1 due to current limit: Active-LoadBalancing
2025-11-04T16:28:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:28:43.152Z:INFO:taskMain.c:5996:Socket #1: Active current 2.0->1.6 due to current limit: Active-LoadBalancing
2025-11-04T16:28:55.152Z:INFO:taskMain.c:5996:Socket #1: Active current 1.6->1.4 due to current limit: Active-LoadBalancing
2025-11-04T16:29:07.152Z:INFO:taskMain.c:5996:Socket #1: Active current 1.4->1.2 due to current limit: Active-LoadBalancing
2025-11-04T16:29:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:29:31.148Z:INFO:taskMain.c:5996:Socket #1: Active current 1.1->1.1 due to current limit: Active-LoadBalancing
2025-11-04T16:30:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T16:30:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:31:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:31:31.136Z:INFO:taskMain.c:5996:Socket #1: Active current 1.0->1.4 due to current limit: Active-LoadBalancing
2025-11-04T16:31:43.136Z:INFO:taskMain.c:5996:Socket #1: Active current 1.4->1.6 due to current limit: Active-LoadBalancing
2025-11-04T16:31:55.132Z:INFO:taskMain.c:5996:Socket #1: Active current 1.6->1.8 due to current limit: Active-LoadBalancing
2025-11-04T16:32:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:32:19.132Z:INFO:taskMain.c:5996:Socket #1: Active current 1.9->1.9 due to current limit: Active-LoadBalancing
2025-11-04T16:33:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:34:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:34:19.117Z:INFO:taskMain.c:5996:Socket #1: Active current 2.0->7.2 due to current limit: Active-LoadBalancing
2025-11-04T16:34:19.164Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-04T16:34:19.171Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-04T16:34:19.179Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-04T16:34:19.191Z:INFO:taskMain.c:6499:Socket #1: CPlow -10.7 V
2025-11-04T16:34:19.199Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.9% (7.1 A)
2025-11-04T16:34:20.167Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-04T16:34:20.175Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-04T16:34:31.117Z:INFO:taskMain.c:5996:Socket #1: Active current 7.2->10.3 due to current limit: Active-LoadBalancing
2025-11-04T16:34:31.277Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.1% (10.3 A)
2025-11-04T16:34:43.117Z:INFO:taskMain.c:5996:Socket #1: Active current 10.3->12.2 due to current limit: Active-LoadBalancing
2025-11-04T16:34:43.394Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.3% (12.2 A)
2025-11-04T16:34:45.007Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 12.2)A
2025-11-04T16:34:49.210Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-04T16:34:49.218Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-04T16:34:49.453Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-04T16:34:49.460Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-04T16:34:50.203Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-04T16:34:53.207Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-04T16:34:53.234Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-04T16:34:53.242Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-04T16:34:53.707Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-04T16:34:53.718Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-04T16:34:54.113Z:INFO:taskLeds.c:338:Brightness set to 8%
2025-11-04T16:34:54.246Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-04T16:34:54.734Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-04T16:34:55.113Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->13.3 due to current limit: Active-LoadBalancing
2025-11-04T16:34:55.746Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.1% (13.3 A)
2025-11-04T16:35:07.113Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->14.0 due to current limit: Active-LoadBalancing
2025-11-04T16:35:07.863Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.3% (14.0 A)
2025-11-04T16:35:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:35:19.113Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-04T16:35:19.980Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.9% (14.3 A)
2025-11-04T16:35:31.109Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-04T16:35:43.109Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-04T16:36:07.105Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T16:36:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:36:19.105Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->9.8 due to current limit: Active-LoadBalancing
2025-11-04T16:36:19.566Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.2% (9.7 A)
2025-11-04T16:36:31.105Z:INFO:taskMain.c:5996:Socket #1: Active current 9.8->6.7 due to current limit: Active-LoadBalancing
2025-11-04T16:36:31.683Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.0% (6.6 A)
2025-11-04T16:36:43.101Z:INFO:taskMain.c:5996:Socket #1: Active current 6.7->4.8 due to current limit: Active-LoadBalancing
2025-11-04T16:36:43.117Z:WARNING:taskMain.c:4698:Socket #1: maximum current(4.79) < minimum current(6.00)
2025-11-04T16:36:43.148Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-04T16:36:43.160Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-04T16:36:43.167Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-04T16:36:43.804Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-04T16:36:44.144Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-11-04T16:36:44.144Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-04T16:36:55.101Z:INFO:taskMain.c:5996:Socket #1: Active current 4.8->3.7 due to current limit: Active-LoadBalancing
2025-11-04T16:37:02.746Z:USER:taskMaster.c:6582:Temperature: 27.5 C
2025-11-04T16:37:07.101Z:INFO:taskMain.c:5996:Socket #1: Active current 3.7->8.2 due to current limit: Active-LoadBalancing
2025-11-04T16:37:07.144Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-04T16:37:07.156Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-04T16:37:07.164Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-04T16:37:07.371Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-04T16:37:07.378Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.6% (8.2 A)
2025-11-04T16:37:08.152Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-04T16:37:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:37:19.097Z:INFO:taskMain.c:5996:Socket #1: Active current 8.2->10.9 due to current limit: Active-LoadBalancing
2025-11-04T16:37:19.257Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.2% (10.9 A)
2025-11-04T16:37:31.097Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->12.6 due to current limit: Active-LoadBalancing
2025-11-04T16:37:31.378Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-04T16:37:37.191Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-04T16:37:37.199Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-04T16:37:37.437Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-04T16:37:37.445Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-04T16:37:38.187Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-04T16:37:41.191Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-04T16:37:41.218Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-04T16:37:41.226Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-04T16:37:41.691Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-04T16:37:41.699Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-04T16:37:42.226Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-04T16:37:42.718Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-04T16:37:43.097Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->13.5 due to current limit: Active-LoadBalancing
2025-11-04T16:37:43.726Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.5% (13.5 A)
2025-11-04T16:37:55.093Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->14.1 due to current limit: Active-LoadBalancing
2025-11-04T16:37:55.843Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.5% (14.1 A)
2025-11-04T16:38:07.093Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.5 due to current limit: Active-LoadBalancing
2025-11-04T16:38:07.964Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-04T16:38:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:38:19.093Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-04T16:38:31.093Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-04T16:38:55.089Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T16:39:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:39:31.085Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-04T16:39:31.785Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-04T16:39:43.085Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->9.4 due to current limit: Active-LoadBalancing
2025-11-04T16:39:43.902Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.6% (9.4 A)
2025-11-04T16:39:55.082Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->6.4 due to current limit: Active-LoadBalancing
2025-11-04T16:39:56.023Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.7% (6.4 A)
2025-11-04T16:40:07.082Z:INFO:taskMain.c:5996:Socket #1: Active current 6.4->4.7 due to current limit: Active-LoadBalancing
2025-11-04T16:40:07.093Z:WARNING:taskMain.c:4698:Socket #1: maximum current(4.66) < minimum current(6.00)
2025-11-04T16:40:07.125Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-04T16:40:07.136Z:INFO:taskMain.c:6499:Socket #1: CPlow 8.6 V
2025-11-04T16:40:07.144Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-04T16:40:07.152Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-04T16:40:08.121Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-04T16:40:08.128Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-11-04T16:40:08.128Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-04T16:40:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:40:19.082Z:INFO:taskMain.c:5996:Socket #1: Active current 4.7->3.6 due to current limit: Active-LoadBalancing
2025-11-04T16:40:19.324Z:USER:taskMaster.c:6684:Socket #1: L1N=229.7V L2N=230.3V L3N=229.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T16:40:19.335Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T16:40:31.078Z:INFO:taskMain.c:5996:Socket #1: Active current 3.6->8.2 due to current limit: Active-LoadBalancing
2025-11-04T16:40:31.121Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-04T16:40:31.136Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-04T16:40:31.144Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-04T16:40:31.347Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-04T16:40:31.355Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.5% (8.1 A)
2025-11-04T16:40:32.128Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-04T16:40:43.078Z:INFO:taskMain.c:5996:Socket #1: Active current 8.2->10.9 due to current limit: Active-LoadBalancing
2025-11-04T16:40:43.238Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.1% (10.9 A)
2025-11-04T16:40:55.078Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->12.5 due to current limit: Active-LoadBalancing
2025-11-04T16:40:55.355Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-04T16:41:01.167Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-04T16:41:01.179Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-04T16:41:01.414Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-04T16:41:01.421Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-04T16:41:02.164Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-04T16:41:05.167Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-04T16:41:05.195Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-04T16:41:05.203Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-04T16:41:05.667Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-04T16:41:05.679Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-04T16:41:06.207Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-04T16:41:06.695Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-04T16:41:07.074Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->13.1 due to current limit: Active-LoadBalancing
2025-11-04T16:41:07.707Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.8% (13.1 A)
2025-11-04T16:41:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:41:19.074Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.5 due to current limit: Active-LoadBalancing
2025-11-04T16:41:19.824Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-04T16:41:31.074Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-11-04T16:41:43.070Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-11-04T16:42:07.070Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-04T16:42:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:42:19.066Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->14.4 due to current limit: Active-LoadBalancing
2025-11-04T16:42:19.406Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.9% (14.3 A)
2025-11-04T16:42:31.066Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-04T16:42:43.066Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->11.4 due to current limit: Active-LoadBalancing
2025-11-04T16:42:43.644Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.9% (11.3 A)
2025-11-04T16:42:55.062Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->9.2 due to current limit: Active-LoadBalancing
2025-11-04T16:42:55.765Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.3% (9.2 A)
2025-11-04T16:43:07.062Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->7.9 due to current limit: Active-LoadBalancing
2025-11-04T16:43:07.882Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.2% (7.9 A)
2025-11-04T16:43:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:43:19.062Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->7.2 due to current limit: Active-LoadBalancing
2025-11-04T16:43:20.000Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.9% (7.1 A)
2025-11-04T16:43:31.058Z:INFO:taskMain.c:5996:Socket #1: Active current 7.2->6.7 due to current limit: Active-LoadBalancing
2025-11-04T16:43:31.109Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.1% (6.7 A)
2025-11-04T16:43:43.058Z:INFO:taskMain.c:5996:Socket #1: Active current 6.7->6.4 due to current limit: Active-LoadBalancing
2025-11-04T16:43:55.058Z:INFO:taskMain.c:5996:Socket #1: Active current 6.4->6.3 due to current limit: Active-LoadBalancing
2025-11-04T16:44:07.054Z:INFO:taskMain.c:5996:Socket #1: Active current 6.3->6.2 due to current limit: Active-LoadBalancing
2025-11-04T16:44:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:44:43.050Z:INFO:taskMain.c:5996:Socket #1: Active current 6.1->6.0 due to current limit: Active-LoadBalancing
2025-11-04T16:44:44.945Z:INFO:active_lb.c:308:SMt:(1.0 1.0 10.0)A Free:(15.0 15.0 6.0)A ALB:(15.0 15.0 6.0)A
2025-11-04T16:44:55.050Z:INFO:taskMain.c:5996:Socket #1: Active current 6.0->9.6 due to current limit: Active-LoadBalancing
2025-11-04T16:44:55.941Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.0% (9.6 A)
2025-11-04T16:45:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T16:45:07.050Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->11.8 due to current limit: Active-LoadBalancing
2025-11-04T16:45:07.062Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.6% (11.8 A)
2025-11-04T16:45:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:45:19.050Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->13.1 due to current limit: Active-LoadBalancing
2025-11-04T16:45:19.167Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.7% (13.0 A)
2025-11-04T16:45:31.046Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.8 due to current limit: Active-LoadBalancing
2025-11-04T16:45:31.289Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-04T16:45:43.046Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->14.1 due to current limit: Active-LoadBalancing
2025-11-04T16:45:55.046Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->13.7 due to current limit: Active-LoadBalancing
2025-11-04T16:45:55.523Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.7% (13.6 A)
2025-11-04T16:46:07.042Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-11-04T16:46:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:46:19.042Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->11.2 due to current limit: Active-LoadBalancing
2025-11-04T16:46:19.761Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.7% (11.2 A)
2025-11-04T16:46:31.042Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->9.1 due to current limit: Active-LoadBalancing
2025-11-04T16:46:31.882Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.2% (9.1 A)
2025-11-04T16:46:43.039Z:INFO:taskMain.c:5996:Socket #1: Active current 9.1->7.9 due to current limit: Active-LoadBalancing
2025-11-04T16:46:44.000Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.1% (7.9 A)
2025-11-04T16:46:55.039Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->7.1 due to current limit: Active-LoadBalancing
2025-11-04T16:46:55.109Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.8% (7.1 A)
2025-11-04T16:47:07.039Z:INFO:taskMain.c:5996:Socket #1: Active current 7.1->6.7 due to current limit: Active-LoadBalancing
2025-11-04T16:47:07.226Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.1% (6.7 A)
2025-11-04T16:47:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:47:15.730Z:INFO:db_base.c:658:Erasing Transaction db sector 0x0000000c, address 0x0000c000 (1)
2025-11-04T16:47:15.742Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-04T16:47:19.035Z:INFO:taskMain.c:5996:Socket #1: Active current 6.7->10.0 due to current limit: Active-LoadBalancing
2025-11-04T16:47:19.347Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.6% (10.0 A)
2025-11-04T16:47:31.035Z:INFO:taskMain.c:5996:Socket #1: Active current 10.0->12.0 due to current limit: Active-LoadBalancing
2025-11-04T16:47:31.464Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.0% (12.0 A)
2025-11-04T16:47:43.035Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->13.2 due to current limit: Active-LoadBalancing
2025-11-04T16:47:43.582Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.0% (13.2 A)
2025-11-04T16:47:55.031Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.4 due to current limit: Active-LoadBalancing
2025-11-04T16:48:07.031Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-11-04T16:48:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:48:31.027Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.1 due to current limit: Active-LoadBalancing
2025-11-04T16:49:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:49:19.023Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->11.4 due to current limit: Active-LoadBalancing
2025-11-04T16:49:19.511Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.9% (11.3 A)
2025-11-04T16:49:31.023Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->9.2 due to current limit: Active-LoadBalancing
2025-11-04T16:49:31.632Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.3% (9.2 A)
2025-11-04T16:49:43.019Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->7.9 due to current limit: Active-LoadBalancing
2025-11-04T16:49:43.750Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.2% (7.9 A)
2025-11-04T16:49:55.019Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->7.2 due to current limit: Active-LoadBalancing
2025-11-04T16:49:55.871Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.9% (7.1 A)
2025-11-04T16:50:07.019Z:INFO:taskMain.c:5996:Socket #1: Active current 7.2->6.7 due to current limit: Active-LoadBalancing
2025-11-04T16:50:07.988Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.1% (6.7 A)
2025-11-04T16:50:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:50:19.015Z:INFO:taskMain.c:5996:Socket #1: Active current 6.7->6.4 due to current limit: Active-LoadBalancing
2025-11-04T16:50:31.015Z:INFO:taskMain.c:5996:Socket #1: Active current 6.4->9.9 due to current limit: Active-LoadBalancing
2025-11-04T16:50:31.214Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.4% (9.8 A)
2025-11-04T16:50:43.015Z:INFO:taskMain.c:5996:Socket #1: Active current 9.9->11.9 due to current limit: Active-LoadBalancing
2025-11-04T16:50:43.335Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.8% (11.9 A)
2025-11-04T16:50:55.011Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->13.1 due to current limit: Active-LoadBalancing
2025-11-04T16:50:55.453Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.9% (13.1 A)
2025-11-04T16:51:07.011Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.9 due to current limit: Active-LoadBalancing
2025-11-04T16:51:07.570Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.1% (13.9 A)
2025-11-04T16:51:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:51:31.007Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.0 due to current limit: Active-LoadBalancing
2025-11-04T16:52:03.148Z:USER:taskMaster.c:6582:Temperature: 27.2 C
2025-11-04T16:52:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:52:43.003Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->11.4 due to current limit: Active-LoadBalancing
2025-11-04T16:52:43.511Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.9% (11.3 A)
2025-11-04T16:52:55.000Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->9.2 due to current limit: Active-LoadBalancing
2025-11-04T16:52:55.628Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.3% (9.2 A)
2025-11-04T16:53:07.000Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->7.9 due to current limit: Active-LoadBalancing
2025-11-04T16:53:07.750Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.2% (7.9 A)
2025-11-04T16:53:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:53:19.000Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->7.2 due to current limit: Active-LoadBalancing
2025-11-04T16:53:19.867Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.9% (7.1 A)
2025-11-04T16:53:30.996Z:INFO:taskMain.c:5996:Socket #1: Active current 7.2->10.3 due to current limit: Active-LoadBalancing
2025-11-04T16:53:31.988Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.1% (10.3 A)
2025-11-04T16:53:42.996Z:INFO:taskMain.c:5996:Socket #1: Active current 10.3->12.2 due to current limit: Active-LoadBalancing
2025-11-04T16:53:43.097Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.2% (12.1 A)
2025-11-04T16:53:54.996Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->13.3 due to current limit: Active-LoadBalancing
2025-11-04T16:53:55.214Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.0% (13.2 A)
2025-11-04T16:54:06.992Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-04T16:54:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:54:30.992Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.5 due to current limit: Active-LoadBalancing
2025-11-04T16:54:31.570Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-04T16:54:42.988Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->14.0 due to current limit: Active-LoadBalancing
2025-11-04T16:54:43.687Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.3% (14.0 A)
2025-11-04T16:54:44.882Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(14.1 14.0 14.8)A
2025-11-04T16:55:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:55:19.230Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=232.0V L3N=230.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T16:55:19.242Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T16:55:42.984Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->11.4 due to current limit: Active-LoadBalancing
2025-11-04T16:55:43.273Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.9% (11.3 A)
2025-11-04T16:55:54.980Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->9.2 due to current limit: Active-LoadBalancing
2025-11-04T16:55:55.390Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.3% (9.2 A)
2025-11-04T16:56:06.980Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->7.9 due to current limit: Active-LoadBalancing
2025-11-04T16:56:07.511Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.2% (7.9 A)
2025-11-04T16:56:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:56:18.980Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->7.2 due to current limit: Active-LoadBalancing
2025-11-04T16:56:19.628Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.9% (7.1 A)
2025-11-04T16:56:30.976Z:INFO:taskMain.c:5996:Socket #1: Active current 7.2->10.3 due to current limit: Active-LoadBalancing
2025-11-04T16:56:31.746Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.1% (10.3 A)
2025-11-04T16:56:42.976Z:INFO:taskMain.c:5996:Socket #1: Active current 10.3->12.2 due to current limit: Active-LoadBalancing
2025-11-04T16:56:43.867Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.2% (12.1 A)
2025-11-04T16:56:54.976Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->13.3 due to current limit: Active-LoadBalancing
2025-11-04T16:56:54.988Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.1% (13.3 A)
2025-11-04T16:57:06.972Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->14.0 due to current limit: Active-LoadBalancing
2025-11-04T16:57:07.093Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.3% (14.0 A)
2025-11-04T16:57:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:57:42.968Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->11.2 due to current limit: Active-LoadBalancing
2025-11-04T16:57:43.449Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.6% (11.2 A)
2025-11-04T16:57:54.968Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->9.1 due to current limit: Active-LoadBalancing
2025-11-04T16:57:55.570Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.1% (9.1 A)
2025-11-04T16:58:06.968Z:INFO:taskMain.c:5996:Socket #1: Active current 9.1->7.9 due to current limit: Active-LoadBalancing
2025-11-04T16:58:07.687Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.1% (7.9 A)
2025-11-04T16:58:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:58:18.964Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->7.1 due to current limit: Active-LoadBalancing
2025-11-04T16:58:19.804Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.8% (7.1 A)
2025-11-04T16:58:30.964Z:INFO:taskMain.c:5996:Socket #1: Active current 7.1->6.7 due to current limit: Active-LoadBalancing
2025-11-04T16:58:31.925Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.1% (6.7 A)
2025-11-04T16:58:42.964Z:INFO:taskMain.c:5996:Socket #1: Active current 6.7->6.4 due to current limit: Active-LoadBalancing
2025-11-04T16:58:54.964Z:INFO:taskMain.c:5996:Socket #1: Active current 6.4->6.2 due to current limit: Active-LoadBalancing
2025-11-04T16:59:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T16:59:18.960Z:INFO:taskMain.c:5996:Socket #1: Active current 6.1->6.1 due to current limit: Active-LoadBalancing
2025-11-04T16:59:30.960Z:INFO:taskMain.c:5996:Socket #1: Active current 6.1->9.7 due to current limit: Active-LoadBalancing
2025-11-04T16:59:31.507Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.0% (9.6 A)
2025-11-04T16:59:42.957Z:INFO:taskMain.c:5996:Socket #1: Active current 9.7->11.8 due to current limit: Active-LoadBalancing
2025-11-04T16:59:43.628Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.6% (11.8 A)
2025-11-04T16:59:54.957Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->13.1 due to current limit: Active-LoadBalancing
2025-11-04T16:59:55.746Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.7% (13.0 A)
2025-11-04T17:00:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T17:00:06.957Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.8 due to current limit: Active-LoadBalancing
2025-11-04T17:00:07.863Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-04T17:00:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:00:18.953Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->14.0 due to current limit: Active-LoadBalancing
2025-11-04T17:00:54.949Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->11.3 due to current limit: Active-LoadBalancing
2025-11-04T17:00:55.320Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.7% (11.2 A)
2025-11-04T17:01:06.949Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->9.2 due to current limit: Active-LoadBalancing
2025-11-04T17:01:07.437Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.2% (9.1 A)
2025-11-04T17:01:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:01:18.949Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->7.9 due to current limit: Active-LoadBalancing
2025-11-04T17:01:19.558Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.1% (7.9 A)
2025-11-04T17:01:30.945Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->7.1 due to current limit: Active-LoadBalancing
2025-11-04T17:01:31.675Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.8% (7.1 A)
2025-11-04T17:01:42.945Z:INFO:taskMain.c:5996:Socket #1: Active current 7.1->6.7 due to current limit: Active-LoadBalancing
2025-11-04T17:01:43.796Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.1% (6.7 A)
2025-11-04T17:01:54.945Z:INFO:taskMain.c:5996:Socket #1: Active current 6.7->10.0 due to current limit: Active-LoadBalancing
2025-11-04T17:01:55.914Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.6% (10.0 A)
2025-11-04T17:02:06.941Z:INFO:taskMain.c:5996:Socket #1: Active current 10.0->12.0 due to current limit: Active-LoadBalancing
2025-11-04T17:02:07.023Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.0% (12.0 A)
2025-11-04T17:02:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:02:18.941Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->13.2 due to current limit: Active-LoadBalancing
2025-11-04T17:02:19.140Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.0% (13.2 A)
2025-11-04T17:02:30.941Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.9 due to current limit: Active-LoadBalancing
2025-11-04T17:02:31.261Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.2% (13.9 A)
2025-11-04T17:03:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:04:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:04:44.820Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-04T17:05:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:05:23.019Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-04T17:05:23.027Z:INFO:db_chargingprofi:26: socket 0
2025-11-04T17:05:23.035Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-04T17:05:23.046Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-04T17:05:23.054Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-04T17:05:23.062Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-04T17:05:23.074Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-04T17:05:23.082Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-04T17:05:23.089Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-04T17:05:23.097Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-04T17:05:23.105Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-04T17:05:23.113Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-04T17:05:23.121Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-04T17:05:23.128Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-04T17:05:23.136Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-04T17:05:23.148Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-04T17:05:23.156Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-04T17:05:23.164Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-04T17:05:23.175Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-04T17:05:23.183Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-04T17:05:23.191Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-04T17:05:23.199Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-04T17:05:23.207Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-04T17:06:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:07:03.507Z:USER:taskMaster.c:6582:Temperature: 27.0 C
2025-11-04T17:07:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:08:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:09:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:10:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:10:19.136Z:USER:taskMaster.c:6684:Socket #1: L1N=230.4V L2N=230.5V L3N=228.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T17:10:19.148Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T17:11:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:12:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:13:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:14:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:14:44.757Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(14.9 14.0 15.0)A
2025-11-04T17:15:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T17:15:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:16:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:17:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:18:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:18:18.839Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-04T17:18:19.550Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-04T17:18:30.839Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-04T17:18:42.835Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-04T17:19:06.835Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T17:19:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:20:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:21:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:21:18.820Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-04T17:21:19.312Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-04T17:21:30.820Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-04T17:21:42.820Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->13.8 due to current limit: Active-LoadBalancing
2025-11-04T17:21:43.546Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-04T17:21:54.816Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.5 due to current limit: Active-LoadBalancing
2025-11-04T17:21:55.667Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-04T17:22:03.910Z:USER:taskMaster.c:6582:Temperature: 26.9 C
2025-11-04T17:22:06.816Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-11-04T17:22:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:22:18.816Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-04T17:22:42.812Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.5 due to current limit: Active-LoadBalancing
2025-11-04T17:22:43.132Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-04T17:22:54.812Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-11-04T17:23:06.808Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-11-04T17:23:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:23:30.808Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-04T17:24:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:24:44.695Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-04T17:25:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:25:19.039Z:USER:taskMaster.c:6684:Socket #1: L1N=237.1V L2N=235.6V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T17:25:19.050Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T17:26:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:27:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:27:54.781Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-04T17:27:55.191Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-04T17:28:06.777Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-04T17:28:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:28:30.777Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-04T17:29:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:29:30.769Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-04T17:29:31.128Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-04T17:29:42.769Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-04T17:29:54.765Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-04T17:30:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T17:30:06.765Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-04T17:30:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:30:30.761Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-04T17:31:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:32:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:33:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:33:42.742Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-04T17:33:43.601Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-04T17:33:54.742Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-04T17:34:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:34:18.738Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.5 due to current limit: Active-LoadBalancing
2025-11-04T17:34:29.941Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-04T17:34:30.210Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-04T17:34:30.738Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-11-04T17:34:36.378Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-04T17:34:36.390Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-04T17:34:42.738Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-04T17:34:44.628Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(14.9 13.2 15.0)A
2025-11-04T17:34:54.734Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.9 due to current limit: Active-LoadBalancing
2025-11-04T17:34:55.304Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.1% (13.9 A)
2025-11-04T17:35:06.734Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->14.3 due to current limit: Active-LoadBalancing
2025-11-04T17:35:07.425Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.9% (14.3 A)
2025-11-04T17:35:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:35:18.734Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-04T17:35:30.730Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-04T17:35:54.730Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T17:36:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:37:04.316Z:USER:taskMaster.c:6582:Temperature: 26.8 C
2025-11-04T17:37:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:38:06.714Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-04T17:38:07.183Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-04T17:38:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:38:18.714Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.0 due to current limit: Active-LoadBalancing
2025-11-04T17:38:19.304Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.2% (13.9 A)
2025-11-04T17:38:30.710Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-04T17:38:31.421Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-04T17:38:42.710Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.3 due to current limit: Active-LoadBalancing
2025-11-04T17:38:54.710Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-04T17:39:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:39:18.707Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.5 due to current limit: Active-LoadBalancing
2025-11-04T17:39:18.886Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-04T17:39:30.707Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-11-04T17:39:42.707Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-11-04T17:40:06.703Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-04T17:40:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:40:18.945Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=233.0V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T17:40:18.957Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T17:41:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:42:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:43:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:44:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:44:44.566Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.6 14.0 15.0)A
2025-11-04T17:45:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T17:45:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:46:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:47:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:48:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:48:15.546Z:INFO:db_base.c:658:Erasing Transaction db sector 0x0000000d, address 0x0000d000 (1)
2025-11-04T17:48:15.558Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-04T17:49:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:50:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:51:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:52:04.621Z:USER:taskMaster.c:6582:Temperature: 26.9 C
2025-11-04T17:52:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:53:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:54:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:54:44.503Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-04T17:55:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:55:18.851Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=233.4V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T17:55:18.863Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T17:56:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:57:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:57:30.593Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-04T17:57:31.593Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-04T17:57:42.589Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-04T17:58:06.589Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-04T17:58:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T17:58:18.585Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-04T17:58:42.585Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-04T17:59:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:00:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T18:00:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:01:06.570Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.8 due to current limit: Active-LoadBalancing
2025-11-04T18:01:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:01:18.570Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.5 due to current limit: Active-LoadBalancing
2025-11-04T18:01:18.820Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-04T18:01:30.566Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-11-04T18:01:42.566Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-04T18:01:54.566Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.5 due to current limit: Active-LoadBalancing
2025-11-04T18:01:55.175Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.5% (13.5 A)
2025-11-04T18:02:06.562Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-11-04T18:02:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:02:18.562Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-11-04T18:02:42.558Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-04T18:03:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:03:30.554Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-04T18:03:31.113Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-04T18:03:42.554Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-04T18:03:54.550Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-11-04T18:04:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:04:18.550Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.1 due to current limit: Active-LoadBalancing
2025-11-04T18:04:44.441Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-11-04T18:05:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:05:30.589Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-04T18:05:30.597Z:INFO:db_chargingprofi:26: socket 0
2025-11-04T18:05:30.605Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-04T18:05:30.617Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-04T18:05:30.625Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-04T18:05:30.632Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-04T18:05:30.644Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-04T18:05:30.652Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-04T18:05:30.660Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-04T18:05:30.667Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-04T18:05:30.675Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-04T18:05:30.683Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-04T18:05:30.691Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-04T18:05:30.699Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-04T18:05:30.707Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-04T18:05:30.718Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-04T18:05:30.726Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-04T18:05:30.734Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-04T18:05:30.746Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-04T18:05:30.753Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-04T18:05:30.761Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-04T18:05:30.769Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-04T18:05:30.777Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-04T18:06:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:07:05.074Z:USER:taskMaster.c:6582:Temperature: 26.8 C
2025-11-04T18:07:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:08:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:09:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:10:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:10:18.753Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=232.1V L3N=231.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T18:10:18.769Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T18:11:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:12:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:13:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:14:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:14:18.488Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-04T18:14:19.464Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-04T18:14:30.484Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-04T18:14:42.484Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-04T18:14:44.378Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 13.8 15.0)A
2025-11-04T18:15:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T18:15:06.480Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-04T18:15:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:15:30.480Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.2 due to current limit: Active-LoadBalancing
2025-11-04T18:15:54.476Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-04T18:16:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:16:54.468Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-04T18:16:54.988Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-04T18:17:06.468Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-04T18:17:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:17:18.468Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.0 due to current limit: Active-LoadBalancing
2025-11-04T18:17:19.226Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.2% (13.9 A)
2025-11-04T18:17:30.464Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.2 due to current limit: Active-LoadBalancing
2025-11-04T18:17:31.347Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.9% (13.1 A)
2025-11-04T18:17:42.464Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->12.7 due to current limit: Active-LoadBalancing
2025-11-04T18:17:43.464Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.1% (12.7 A)
2025-11-04T18:17:54.464Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.4 due to current limit: Active-LoadBalancing
2025-11-04T18:18:06.460Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.3 due to current limit: Active-LoadBalancing
2025-11-04T18:18:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:18:18.460Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-04T18:18:30.460Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-11-04T18:18:30.929Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-04T18:18:42.457Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-04T18:18:54.457Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-04T18:19:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:19:18.453Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-04T18:20:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:21:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:22:05.433Z:USER:taskMaster.c:6582:Temperature: 26.6 C
2025-11-04T18:22:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:23:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:24:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:24:44.316Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-04T18:25:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:25:18.660Z:USER:taskMaster.c:6684:Socket #1: L1N=231.5V L2N=230.9V L3N=229.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T18:25:18.671Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T18:26:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:27:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:28:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:29:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:30:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T18:30:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:31:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:32:06.375Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.8 due to current limit: Active-LoadBalancing
2025-11-04T18:32:06.921Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.9% (13.7 A)
2025-11-04T18:32:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:32:18.371Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->14.0 due to current limit: Active-LoadBalancing
2025-11-04T18:33:06.367Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-04T18:33:06.507Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-04T18:33:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:33:18.367Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-04T18:33:30.363Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-04T18:33:42.363Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-04T18:34:06.359Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-04T18:34:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:34:44.250Z:INFO:active_lb.c:308:SMt:(2.0 1.0 2.0)A Free:(14.0 15.0 14.0)A ALB:(14.0 15.0 14.0)A
2025-11-04T18:35:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:35:30.351Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.8 due to current limit: Active-LoadBalancing
2025-11-04T18:35:42.351Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.5 due to current limit: Active-LoadBalancing
2025-11-04T18:35:43.042Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-04T18:35:54.351Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-11-04T18:36:06.347Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-04T18:36:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:36:30.347Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.1 due to current limit: Active-LoadBalancing
2025-11-04T18:37:05.835Z:USER:taskMaster.c:6582:Temperature: 26.2 C
2025-11-04T18:37:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:38:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:39:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:40:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:40:18.566Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=232.5V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T18:40:18.578Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T18:41:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:42:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:43:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:44:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:44:44.187Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(14.0 13.0 15.0)A ALB:(14.2 13.0 15.0)A
2025-11-04T18:45:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T18:45:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:46:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:47:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:48:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:49:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:49:15.257Z:INFO:db_base.c:658:Erasing Transaction db sector 0x0000000e, address 0x0000e000 (1)
2025-11-04T18:49:15.269Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-04T18:50:06.261Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.8 due to current limit: Active-LoadBalancing
2025-11-04T18:50:06.500Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-04T18:50:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:50:18.257Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->14.3 due to current limit: Active-LoadBalancing
2025-11-04T18:50:18.617Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.8% (14.3 A)
2025-11-04T18:50:30.257Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-04T18:50:42.257Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-11-04T18:50:54.253Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-04T18:51:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:51:30.250Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.0 due to current limit: Active-LoadBalancing
2025-11-04T18:52:06.242Z:USER:taskMaster.c:6582:Temperature: 26.1 C
2025-11-04T18:52:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:52:54.242Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-04T18:52:55.152Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-04T18:53:06.242Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-04T18:53:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:53:18.238Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->13.8 due to current limit: Active-LoadBalancing
2025-11-04T18:53:18.371Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-04T18:53:30.238Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.5 due to current limit: Active-LoadBalancing
2025-11-04T18:53:30.488Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-04T18:53:42.238Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-11-04T18:53:54.234Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-04T18:54:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:54:18.234Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.1 due to current limit: Active-LoadBalancing
2025-11-04T18:54:44.125Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-04T18:55:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:55:18.472Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=233.8V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T18:55:18.484Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T18:56:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:57:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:58:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T18:59:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:00:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T19:00:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:01:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:02:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:03:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:04:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:04:44.062Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-04T19:05:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:05:38.109Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-04T19:05:38.117Z:INFO:db_chargingprofi:26: socket 0
2025-11-04T19:05:38.125Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-04T19:05:38.136Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-04T19:05:38.144Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-04T19:05:38.152Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-04T19:05:38.164Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-04T19:05:38.171Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-04T19:05:38.179Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-04T19:05:38.187Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-04T19:05:38.195Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-04T19:05:38.203Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-04T19:05:38.210Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-04T19:05:38.218Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-04T19:05:38.226Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-04T19:05:38.238Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-04T19:05:38.246Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-04T19:05:38.253Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-04T19:05:38.265Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-04T19:05:38.273Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-04T19:05:38.281Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-04T19:05:38.289Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-04T19:05:38.296Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-04T19:06:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:07:06.546Z:USER:taskMaster.c:6582:Temperature: 26.5 C
2025-11-04T19:07:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:08:06.195Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-04T19:08:07.078Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-04T19:08:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:08:18.195Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-04T19:08:30.195Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-04T19:08:54.191Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-04T19:09:06.191Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->14.4 due to current limit: Active-LoadBalancing
2025-11-04T19:09:06.660Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.9% (14.3 A)
2025-11-04T19:09:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:09:18.187Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-04T19:09:30.187Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-04T19:09:54.183Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T19:10:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:10:18.183Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.6 due to current limit: Active-LoadBalancing
2025-11-04T19:10:18.363Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-04T19:10:18.375Z:USER:taskMaster.c:6684:Socket #1: L1N=235.6V L2N=235.4V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T19:10:18.386Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T19:10:30.179Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-04T19:10:42.179Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-04T19:11:06.175Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-04T19:11:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:11:18.175Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.0 due to current limit: Active-LoadBalancing
2025-11-04T19:11:30.175Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.2 due to current limit: Active-LoadBalancing
2025-11-04T19:11:31.074Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.9% (13.1 A)
2025-11-04T19:11:42.171Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->12.7 due to current limit: Active-LoadBalancing
2025-11-04T19:11:42.187Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.1% (12.7 A)
2025-11-04T19:11:54.171Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.4 due to current limit: Active-LoadBalancing
2025-11-04T19:12:06.171Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.3 due to current limit: Active-LoadBalancing
2025-11-04T19:12:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:12:18.167Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.6 due to current limit: Active-LoadBalancing
2025-11-04T19:12:30.167Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.7 due to current limit: Active-LoadBalancing
2025-11-04T19:12:42.167Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-04T19:13:06.164Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-04T19:13:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:14:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:14:44.000Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-04T19:15:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T19:15:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:16:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:17:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:17:18.136Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->11.7 due to current limit: Active-LoadBalancing
2025-11-04T19:17:18.476Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.5% (11.7 A)
2025-11-04T19:17:30.136Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->10.2 due to current limit: Active-LoadBalancing
2025-11-04T19:17:30.597Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.0% (10.2 A)
2025-11-04T19:17:42.136Z:INFO:taskMain.c:5996:Socket #1: Active current 10.2->11.7 due to current limit: Active-LoadBalancing
2025-11-04T19:17:42.714Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.5% (11.7 A)
2025-11-04T19:17:54.132Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->12.6 due to current limit: Active-LoadBalancing
2025-11-04T19:17:54.835Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-11-04T19:18:06.132Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->13.0 due to current limit: Active-LoadBalancing
2025-11-04T19:18:06.953Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.6% (13.0 A)
2025-11-04T19:18:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:18:18.132Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->11.9 due to current limit: Active-LoadBalancing
2025-11-04T19:18:19.070Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.8% (11.9 A)
2025-11-04T19:18:30.128Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->10.7 due to current limit: Active-LoadBalancing
2025-11-04T19:18:30.179Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.9% (10.7 A)
2025-11-04T19:18:42.128Z:INFO:taskMain.c:5996:Socket #1: Active current 10.7->10.0 due to current limit: Active-LoadBalancing
2025-11-04T19:18:42.300Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.7% (10.0 A)
2025-11-04T19:18:54.128Z:INFO:taskMain.c:5996:Socket #1: Active current 10.0->12.0 due to current limit: Active-LoadBalancing
2025-11-04T19:18:54.417Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.0% (12.0 A)
2025-11-04T19:19:06.125Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->13.0 due to current limit: Active-LoadBalancing
2025-11-04T19:19:06.535Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.6% (13.0 A)
2025-11-04T19:19:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:20:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:21:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:22:06.953Z:USER:taskMaster.c:6582:Temperature: 26.4 C
2025-11-04T19:22:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:23:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:24:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:24:43.933Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-04T19:25:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:25:18.281Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=233.8V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T19:25:18.292Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T19:26:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:26:18.082Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-04T19:26:18.769Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-04T19:26:30.078Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-04T19:26:42.078Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-04T19:27:06.074Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-04T19:27:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:28:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:29:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:29:18.062Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-04T19:29:18.531Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-04T19:29:30.062Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.0 due to current limit: Active-LoadBalancing
2025-11-04T19:29:30.652Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.5% (12.9 A)
2025-11-04T19:29:42.058Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-11-04T19:29:42.769Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-04T19:29:54.058Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.3 due to current limit: Active-LoadBalancing
2025-11-04T19:30:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T19:30:06.058Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-04T19:30:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:30:30.054Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.5 due to current limit: Active-LoadBalancing
2025-11-04T19:30:42.054Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-04T19:30:54.050Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-04T19:31:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:31:18.050Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-04T19:32:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:33:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:34:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:34:30.031Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->11.7 due to current limit: Active-LoadBalancing
2025-11-04T19:34:30.589Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.5% (11.7 A)
2025-11-04T19:34:35.621Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-04T19:34:35.632Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-04T19:34:42.027Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->10.2 due to current limit: Active-LoadBalancing
2025-11-04T19:34:42.707Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.0% (10.2 A)
2025-11-04T19:34:43.871Z:INFO:active_lb.c:308:SMt:(8.0 3.0 1.0)A Free:(8.0 13.0 15.0)A ALB:(10.2 13.0 15.0)A
2025-11-04T19:34:54.027Z:INFO:taskMain.c:5996:Socket #1: Active current 10.2->10.9 due to current limit: Active-LoadBalancing
2025-11-04T19:34:54.828Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.2% (10.9 A)
2025-11-04T19:35:06.027Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->10.2 due to current limit: Active-LoadBalancing
2025-11-04T19:35:06.945Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.9% (10.1 A)
2025-11-04T19:35:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:35:18.023Z:INFO:taskMain.c:5996:Socket #1: Active current 10.2->10.5 due to current limit: Active-LoadBalancing
2025-11-04T19:35:30.023Z:INFO:taskMain.c:5996:Socket #1: Active current 10.5->10.3 due to current limit: Active-LoadBalancing
2025-11-04T19:35:42.023Z:INFO:taskMain.c:5996:Socket #1: Active current 10.3->12.2 due to current limit: Active-LoadBalancing
2025-11-04T19:35:42.292Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.2% (12.1 A)
2025-11-04T19:35:54.019Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->13.0 due to current limit: Active-LoadBalancing
2025-11-04T19:35:54.410Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.6% (13.0 A)
2025-11-04T19:36:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:37:07.308Z:USER:taskMaster.c:6582:Temperature: 26.4 C
2025-11-04T19:37:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:37:30.011Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-11-04T19:37:30.351Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-11-04T19:37:42.007Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-11-04T19:38:06.007Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-04T19:38:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:39:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:40:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:40:18.238Z:USER:taskMaster.c:6684:Socket #1: L1N=234.9V L2N=235.4V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T19:40:18.250Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T19:41:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:42:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:42:41.976Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-04T19:42:42.406Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-04T19:42:53.976Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-04T19:43:05.976Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-04T19:43:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:43:29.972Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-04T19:44:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:44:43.808Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.4 14.0 15.0)A
2025-11-04T19:45:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T19:45:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:45:54.007Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-04T19:45:54.289Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-04T19:46:06.007Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.0 due to current limit: Active-LoadBalancing
2025-11-04T19:46:06.406Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.5% (12.9 A)
2025-11-04T19:46:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:46:18.003Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-11-04T19:46:18.523Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-04T19:46:30.003Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.3 due to current limit: Active-LoadBalancing
2025-11-04T19:46:42.003Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-04T19:47:06.000Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-11-04T19:47:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:47:29.996Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-11-04T19:47:30.226Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-11-04T19:47:41.996Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.7 due to current limit: Active-LoadBalancing
2025-11-04T19:47:53.996Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-04T19:48:05.992Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-11-04T19:48:06.582Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-11-04T19:48:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:48:17.992Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-04T19:48:29.992Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.6 due to current limit: Active-LoadBalancing
2025-11-04T19:48:41.988Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.7 due to current limit: Active-LoadBalancing
2025-11-04T19:48:53.988Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-04T19:49:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:49:29.984Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.0 due to current limit: Active-LoadBalancing
2025-11-04T19:50:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:50:15.972Z:INFO:db_base.c:658:Erasing Transaction db sector 0x0000000f, address 0x0000f000 (1)
2025-11-04T19:50:15.984Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-04T19:51:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:52:07.710Z:USER:taskMaster.c:6582:Temperature: 26.4 C
2025-11-04T19:52:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:53:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:54:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:54:43.746Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-04T19:55:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:55:17.949Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-04T19:55:18.191Z:USER:taskMaster.c:6684:Socket #1: L1N=233.2V L2N=233.1V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T19:55:18.207Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T19:55:18.816Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-04T19:55:29.945Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-04T19:55:41.945Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-04T19:56:05.941Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-04T19:56:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:57:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:58:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:58:29.925Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-04T19:58:30.699Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-04T19:58:41.925Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.0 due to current limit: Active-LoadBalancing
2025-11-04T19:58:42.816Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.5% (12.9 A)
2025-11-04T19:58:53.925Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-11-04T19:58:53.937Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-04T19:59:05.921Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.3 due to current limit: Active-LoadBalancing
2025-11-04T19:59:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T19:59:17.921Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-04T19:59:41.921Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-11-04T19:59:53.917Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.4 due to current limit: Active-LoadBalancing
2025-11-04T19:59:54.519Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-11-04T20:00:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T20:00:05.917Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.7 due to current limit: Active-LoadBalancing
2025-11-04T20:00:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:00:17.917Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-04T20:00:29.914Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-11-04T20:00:41.914Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-04T20:00:53.914Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-04T20:01:05.910Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-11-04T20:01:06.222Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-04T20:01:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:01:17.910Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-04T20:01:29.910Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.4 due to current limit: Active-LoadBalancing
2025-11-04T20:01:41.906Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.3 due to current limit: Active-LoadBalancing
2025-11-04T20:01:53.906Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-04T20:02:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:02:17.902Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.5 due to current limit: Active-LoadBalancing
2025-11-04T20:02:17.917Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-11-04T20:02:29.902Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-04T20:02:41.902Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-04T20:03:05.898Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-11-04T20:03:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:04:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:04:43.683Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 12.0 15.0)A
2025-11-04T20:05:05.886Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-11-04T20:05:06.566Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-11-04T20:05:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:05:17.882Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-11-04T20:05:29.882Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-11-04T20:05:41.882Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-11-04T20:05:41.910Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-11-04T20:05:45.679Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-04T20:05:45.687Z:INFO:db_chargingprofi:26: socket 0
2025-11-04T20:05:45.695Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-04T20:05:45.703Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-04T20:05:45.710Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-04T20:05:45.722Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-04T20:05:45.734Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-04T20:05:45.742Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-04T20:05:45.750Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-04T20:05:45.757Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-04T20:05:45.765Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-04T20:05:45.773Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-04T20:05:45.781Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-04T20:05:45.789Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-04T20:05:45.796Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-04T20:05:45.808Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-04T20:05:45.816Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-04T20:05:45.824Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-04T20:05:45.832Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-04T20:05:45.843Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-04T20:05:45.847Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-04T20:05:45.855Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-04T20:05:45.867Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-04T20:05:53.878Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-04T20:06:05.878Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-04T20:06:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:06:29.878Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-11-04T20:06:53.875Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-11-04T20:06:54.625Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-11-04T20:07:05.875Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.3 due to current limit: Active-LoadBalancing
2025-11-04T20:07:08.117Z:USER:taskMaster.c:6582:Temperature: 26.5 C
2025-11-04T20:07:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:07:17.871Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.6 due to current limit: Active-LoadBalancing
2025-11-04T20:07:29.871Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.3 due to current limit: Active-LoadBalancing
2025-11-04T20:07:41.871Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-04T20:08:05.867Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.5 due to current limit: Active-LoadBalancing
2025-11-04T20:08:06.328Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-11-04T20:08:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:08:17.867Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-04T20:08:29.863Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-04T20:08:53.863Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.5 due to current limit: Active-LoadBalancing
2025-11-04T20:08:54.800Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-11-04T20:09:05.859Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-04T20:09:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:09:17.859Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->13.2 due to current limit: Active-LoadBalancing
2025-11-04T20:09:18.027Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.0% (13.2 A)
2025-11-04T20:09:29.859Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.5 due to current limit: Active-LoadBalancing
2025-11-04T20:09:41.855Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-11-04T20:09:53.855Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-11-04T20:10:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:10:17.851Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-04T20:10:18.148Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=232.6V L3N=231.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T20:10:18.160Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T20:11:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:12:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:12:29.839Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-04T20:12:29.910Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-04T20:12:41.835Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-04T20:12:53.835Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->12.8 due to current limit: Active-LoadBalancing
2025-11-04T20:12:54.144Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.3% (12.8 A)
2025-11-04T20:13:05.835Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-11-04T20:13:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:13:17.832Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-04T20:13:29.832Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-04T20:13:41.832Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-11-04T20:13:42.621Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-04T20:13:53.832Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-04T20:14:05.828Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-04T20:14:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:14:29.828Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-04T20:14:43.617Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(14.0 13.0 15.0)A ALB:(14.6 13.0 15.0)A
2025-11-04T20:15:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T20:15:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:16:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:17:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:18:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:19:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:20:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:21:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:22:05.777Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-04T20:22:06.546Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-04T20:22:08.472Z:USER:taskMaster.c:6582:Temperature: 26.2 C
2025-11-04T20:22:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:22:17.777Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-04T20:22:29.777Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-04T20:22:53.773Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-04T20:23:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:23:41.769Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-04T20:23:42.488Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.9% (14.3 A)
2025-11-04T20:23:53.765Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-04T20:24:05.765Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-04T20:24:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:24:17.765Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.5 due to current limit: Active-LoadBalancing
2025-11-04T20:24:29.761Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-04T20:24:41.761Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-04T20:24:43.554Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.2 15.0)A
2025-11-04T20:25:05.757Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->13.7 due to current limit: Active-LoadBalancing
2025-11-04T20:25:06.308Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.7% (13.6 A)
2025-11-04T20:25:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:25:17.757Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.4 due to current limit: Active-LoadBalancing
2025-11-04T20:25:18.050Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=233.4V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T20:25:18.062Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T20:25:29.757Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->12.8 due to current limit: Active-LoadBalancing
2025-11-04T20:25:30.546Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.3% (12.8 A)
2025-11-04T20:25:41.753Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-11-04T20:25:53.753Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-04T20:26:05.753Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-04T20:26:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:26:17.750Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-11-04T20:26:18.000Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-04T20:26:29.750Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-04T20:26:41.750Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-04T20:27:05.746Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-04T20:27:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:28:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:28:17.738Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-11-04T20:28:18.179Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-04T20:28:29.738Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-11-04T20:28:53.734Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-04T20:29:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:30:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T20:30:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:31:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:32:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:33:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:34:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:34:41.699Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.0 due to current limit: Active-LoadBalancing
2025-11-04T20:34:43.492Z:INFO:active_lb.c:308:SMt:(3.0 2.0 1.0)A Free:(13.0 14.0 15.0)A ALB:(13.0 13.4 15.0)A
2025-11-04T20:35:05.695Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-04T20:35:06.175Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-04T20:35:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:35:17.695Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.9 due to current limit: Active-LoadBalancing
2025-11-04T20:35:18.292Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.1% (13.9 A)
2025-11-04T20:35:53.691Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.0 due to current limit: Active-LoadBalancing
2025-11-04T20:36:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:37:08.878Z:USER:taskMaster.c:6582:Temperature: 26.5 C
2025-11-04T20:37:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:37:53.679Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-04T20:37:53.820Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-04T20:38:05.675Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-04T20:38:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:38:17.675Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->12.8 due to current limit: Active-LoadBalancing
2025-11-04T20:38:18.054Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.3% (12.8 A)
2025-11-04T20:38:29.675Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-11-04T20:38:41.671Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-04T20:38:53.671Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-04T20:39:05.671Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-11-04T20:39:06.531Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-04T20:39:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:39:17.667Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-04T20:39:29.667Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-04T20:39:53.664Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-04T20:40:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:40:17.957Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.2V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T20:40:17.968Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T20:41:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:42:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:43:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:44:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:44:43.429Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(14.0 13.0 15.0)A ALB:(14.6 13.0 15.0)A
2025-11-04T20:45:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T20:45:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:46:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:47:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:48:05.613Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-04T20:48:05.812Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-04T20:48:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:48:17.613Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-04T20:48:29.613Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-04T20:48:53.609Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-04T20:49:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:50:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:51:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:51:15.238Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000010, address 0x00010000 (1)
2025-11-04T20:51:15.250Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-04T20:51:17.593Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-04T20:51:17.695Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-04T20:51:29.593Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.0 due to current limit: Active-LoadBalancing
2025-11-04T20:51:29.812Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.5% (12.9 A)
2025-11-04T20:51:41.589Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-11-04T20:51:41.929Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-04T20:51:53.589Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.3 due to current limit: Active-LoadBalancing
2025-11-04T20:52:05.589Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-04T20:52:09.234Z:USER:taskMaster.c:6582:Temperature: 26.2 C
2025-11-04T20:52:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:52:29.585Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.5 due to current limit: Active-LoadBalancing
2025-11-04T20:52:41.585Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-04T20:52:53.582Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-04T20:53:05.582Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-11-04T20:53:05.753Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-04T20:53:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:53:17.582Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-04T20:53:29.578Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.4 due to current limit: Active-LoadBalancing
2025-11-04T20:53:41.578Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.7 due to current limit: Active-LoadBalancing
2025-11-04T20:53:53.578Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-04T20:54:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:54:17.574Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-04T20:54:43.367Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-04T20:55:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:55:17.863Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=234.7V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T20:55:17.875Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T20:56:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:56:17.562Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-11-04T20:56:17.632Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-04T20:56:29.562Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-11-04T20:56:41.558Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-11-04T20:56:53.558Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-04T20:57:05.558Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.6 due to current limit: Active-LoadBalancing
2025-11-04T20:57:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:57:17.554Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.7 due to current limit: Active-LoadBalancing
2025-11-04T20:57:29.554Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-04T20:57:53.550Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-04T20:58:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:59:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T20:59:53.539Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-11-04T20:59:53.738Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-04T21:00:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T21:00:05.539Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-11-04T21:00:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:00:17.535Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-11-04T21:00:29.535Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-11-04T21:00:41.535Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->13.0 due to current limit: Active-LoadBalancing
2025-11-04T21:00:42.214Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.7% (13.0 A)
2025-11-04T21:00:53.531Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-04T21:00:54.332Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-04T21:01:05.531Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-04T21:01:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:01:17.531Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-04T21:01:41.527Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-04T21:02:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:03:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:04:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:04:43.304Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.1 14.0 15.0)A
2025-11-04T21:05:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:05:41.503Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-04T21:05:42.152Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.9% (14.3 A)
2025-11-04T21:05:53.250Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-04T21:05:53.257Z:INFO:db_chargingprofi:26: socket 0
2025-11-04T21:05:53.265Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-04T21:05:53.273Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-04T21:05:53.281Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-04T21:05:53.292Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-04T21:05:53.300Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-04T21:05:53.308Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-04T21:05:53.320Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-04T21:05:53.328Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-04T21:05:53.335Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-04T21:05:53.343Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-04T21:05:53.351Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-04T21:05:53.359Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-04T21:05:53.367Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-04T21:05:53.378Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-04T21:05:53.386Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-04T21:05:53.394Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-04T21:05:53.402Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-04T21:05:53.410Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-04T21:05:53.417Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-04T21:05:53.425Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-04T21:05:53.433Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-04T21:05:53.500Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-04T21:06:05.500Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-04T21:06:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:06:17.500Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-04T21:06:29.496Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-04T21:06:53.496Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-04T21:07:09.636Z:USER:taskMaster.c:6582:Temperature: 26.2 C
2025-11-04T21:07:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:08:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:09:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:10:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:10:17.769Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=235.5V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T21:10:17.781Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T21:11:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:12:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:13:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:14:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:14:43.238Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-04T21:15:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T21:15:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:16:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:17:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:18:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:19:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:20:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:21:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:22:09.992Z:USER:taskMaster.c:6582:Temperature: 26.4 C
2025-11-04T21:22:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:23:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:24:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:24:43.175Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-04T21:25:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:25:17.671Z:USER:taskMaster.c:6684:Socket #1: L1N=236.9V L2N=237.3V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T21:25:17.683Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T21:26:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:27:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:28:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:29:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:30:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T21:30:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:31:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:32:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:33:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:34:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:34:28.250Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-04T21:34:28.519Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-04T21:34:34.863Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-04T21:34:34.875Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-04T21:34:43.113Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-04T21:34:43.164Z:INFO:comFaults.c:482:Reset fault status
2025-11-04T21:35:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:36:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:37:10.347Z:USER:taskMaster.c:6582:Temperature: 26.5 C
2025-11-04T21:37:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:38:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:39:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:40:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:40:17.578Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.3V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T21:40:17.589Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T21:41:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:42:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:43:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:44:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:44:43.050Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-04T21:45:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T21:45:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:46:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:47:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:48:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:49:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:50:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:51:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:52:10.753Z:USER:taskMaster.c:6582:Temperature: 26.2 C
2025-11-04T21:52:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:53:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:53:15.058Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000011, address 0x00011000 (1)
2025-11-04T21:53:15.066Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-04T21:54:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:54:42.988Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.1 14.0 15.0)A
2025-11-04T21:54:53.242Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.7 due to current limit: Active-LoadBalancing
2025-11-04T21:54:54.070Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.7% (13.6 A)
2025-11-04T21:55:05.242Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-11-04T21:55:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:55:17.484Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=235.6V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T21:55:17.496Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T21:55:29.238Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-04T21:56:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:57:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:58:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T21:59:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:00:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T22:00:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:01:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:02:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:03:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:04:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:04:42.921Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.0 14.0 15.0)A
2025-11-04T22:05:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:06:00.769Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-04T22:06:00.777Z:INFO:db_chargingprofi:26: socket 0
2025-11-04T22:06:00.785Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-04T22:06:00.792Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-04T22:06:00.800Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-04T22:06:00.812Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-04T22:06:00.820Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-04T22:06:00.832Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-04T22:06:00.839Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-04T22:06:00.847Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-04T22:06:00.855Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-04T22:06:00.863Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-04T22:06:00.871Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-04T22:06:00.878Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-04T22:06:00.886Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-04T22:06:00.898Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-04T22:06:00.906Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-04T22:06:00.914Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-04T22:06:00.921Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-04T22:06:00.929Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-04T22:06:00.937Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-04T22:06:00.945Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-04T22:06:00.957Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-04T22:06:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:07:11.109Z:USER:taskMaster.c:6582:Temperature: 26.1 C
2025-11-04T22:07:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:08:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:09:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:10:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:10:17.386Z:USER:taskMaster.c:6684:Socket #1: L1N=235.8V L2N=235.6V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T22:10:17.398Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T22:11:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:12:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:13:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:14:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:14:42.859Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-04T22:15:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T22:15:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:16:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:17:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:17:53.097Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-04T22:17:53.585Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-04T22:18:05.093Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-04T22:18:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:18:17.093Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-04T22:18:41.089Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T22:19:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:20:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:20:53.078Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-04T22:20:53.347Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-04T22:21:05.074Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-04T22:21:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:21:17.074Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-04T22:21:41.070Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-04T22:21:53.070Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->13.6 due to current limit: Active-LoadBalancing
2025-11-04T22:21:53.941Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.7% (13.6 A)
2025-11-04T22:22:05.070Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-04T22:22:11.511Z:USER:taskMaster.c:6582:Temperature: 26.1 C
2025-11-04T22:22:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:22:17.070Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-11-04T22:22:29.066Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.5 due to current limit: Active-LoadBalancing
2025-11-04T22:22:41.066Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-11-04T22:22:53.066Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.4 due to current limit: Active-LoadBalancing
2025-11-04T22:23:05.062Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.3 due to current limit: Active-LoadBalancing
2025-11-04T22:23:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:23:17.062Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-04T22:23:29.062Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.5 due to current limit: Active-LoadBalancing
2025-11-04T22:23:41.058Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-11-04T22:23:53.058Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.4 due to current limit: Active-LoadBalancing
2025-11-04T22:24:05.058Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.3 due to current limit: Active-LoadBalancing
2025-11-04T22:24:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:24:17.054Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-04T22:24:41.054Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.5 due to current limit: Active-LoadBalancing
2025-11-04T22:24:41.582Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-04T22:24:42.796Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(13.5 15.0 15.0)A
2025-11-04T22:24:53.050Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-11-04T22:25:05.050Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-11-04T22:25:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:25:17.292Z:USER:taskMaster.c:6684:Socket #1: L1N=236.0V L2N=236.0V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T22:25:17.304Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T22:25:29.046Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-04T22:26:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:26:29.042Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-04T22:26:29.640Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.9% (14.3 A)
2025-11-04T22:26:41.039Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-04T22:26:53.039Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-04T22:27:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:27:17.035Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T22:28:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:29:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:30:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T22:30:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:31:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:32:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:32:41.003Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-04T22:32:41.281Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-04T22:32:53.000Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-04T22:33:05.000Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-04T22:33:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:33:28.996Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-04T22:34:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:34:16.992Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-04T22:34:17.222Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-04T22:34:28.992Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-04T22:34:40.988Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-04T22:34:42.734Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.8 15.0 15.0)A
2025-11-04T22:35:04.988Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T22:35:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:35:40.984Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-04T22:35:41.042Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-04T22:35:52.980Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-04T22:36:04.980Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-04T22:36:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:36:28.980Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-04T22:37:11.917Z:USER:taskMaster.c:6582:Temperature: 26.0 C
2025-11-04T22:37:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:37:52.968Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-04T22:37:53.339Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-04T22:38:04.968Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-04T22:38:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:38:16.968Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-04T22:38:40.964Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T22:39:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:40:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:40:17.199Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=233.4V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T22:40:17.210Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T22:41:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:42:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:43:04.937Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-04T22:43:05.398Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-04T22:43:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:43:16.937Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-04T22:43:28.933Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-04T22:43:40.933Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-04T22:44:04.929Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T22:44:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:44:42.671Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T22:45:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T22:45:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:46:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:47:04.910Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-04T22:47:05.750Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-04T22:47:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:47:16.910Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-04T22:47:28.910Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-04T22:47:52.906Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-04T22:48:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:48:40.902Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-04T22:48:41.691Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-04T22:48:52.898Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-04T22:49:04.898Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-04T22:49:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:49:28.894Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T22:50:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:51:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:52:12.273Z:USER:taskMaster.c:6582:Temperature: 25.9 C
2025-11-04T22:52:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:53:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:54:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:54:15.558Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000012, address 0x00012000 (1)
2025-11-04T22:54:15.570Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-04T22:54:42.605Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T22:55:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:55:17.105Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=233.3V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T22:55:17.117Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T22:56:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:57:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:58:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T22:59:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:00:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T23:00:00.085Z:INFO:taskMaster.c:6353:Socket #1: external current limit 15.9 A until 2025-11-05T23:00:00Z
2025-11-04T23:00:00.101Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-04T23:00:00.109Z:INFO:db_chargingprofi:26: socket 0
2025-11-04T23:00:00.117Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-04T23:00:00.125Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-04T23:00:00.132Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-04T23:00:00.140Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-04T23:00:00.152Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-04T23:00:00.160Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-04T23:00:00.167Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-04T23:00:00.179Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-04T23:00:00.187Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-04T23:00:00.195Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-04T23:00:00.203Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-04T23:00:00.210Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-04T23:00:00.218Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-04T23:00:00.226Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-04T23:00:00.234Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-04T23:00:00.246Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-04T23:00:00.253Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-04T23:00:00.261Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-04T23:00:00.269Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-04T23:00:00.277Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-04T23:00:00.285Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-04T23:00:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:00:28.828Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-04T23:00:29.617Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-04T23:00:40.824Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-04T23:00:52.824Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-04T23:01:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:01:16.820Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-04T23:02:04.816Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-04T23:02:05.546Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-04T23:02:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:02:16.816Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-04T23:02:28.812Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-04T23:02:52.812Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T23:03:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:04:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:04:42.542Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T23:05:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:06:04.792Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-04T23:06:04.890Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-04T23:06:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:06:16.789Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-04T23:06:28.789Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-04T23:06:52.785Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-04T23:07:12.179Z:USER:taskMaster.c:6582:Temperature: 26.0 C
2025-11-04T23:07:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:07:52.781Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-04T23:07:52.949Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-04T23:08:04.777Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-04T23:08:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:08:16.777Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-04T23:08:40.773Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T23:09:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:10:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:10:17.007Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.0V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T23:10:17.019Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T23:11:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:12:04.753Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-04T23:12:05.421Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-04T23:12:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:12:16.753Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-04T23:12:28.750Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-04T23:12:52.750Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-04T23:13:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:13:40.742Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-04T23:13:41.363Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-04T23:13:52.742Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-04T23:14:04.742Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-04T23:14:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:14:28.738Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T23:14:42.480Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T23:15:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T23:15:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:16:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:17:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:18:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:19:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:20:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:21:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:22:12.535Z:USER:taskMaster.c:6582:Temperature: 25.6 C
2025-11-04T23:22:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:23:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:24:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:24:28.675Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-04T23:24:28.703Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-04T23:24:40.671Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-04T23:24:42.417Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.4 15.0 15.0)A
2025-11-04T23:24:52.671Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-04T23:25:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:25:16.671Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-04T23:25:16.914Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=235.8V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T23:25:16.925Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T23:26:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:26:16.664Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-04T23:26:16.761Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-04T23:26:28.664Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-04T23:26:40.660Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-04T23:27:04.660Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T23:27:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:28:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:28:16.652Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-04T23:28:16.941Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-04T23:28:28.648Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-04T23:28:40.648Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-04T23:28:52.648Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-04T23:28:53.296Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-04T23:29:04.644Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-04T23:29:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:29:16.644Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-04T23:29:40.691Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T23:30:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T23:30:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:31:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:32:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:33:04.671Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-04T23:33:04.761Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-04T23:33:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:33:16.667Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-04T23:33:28.667Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-04T23:33:52.664Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-04T23:34:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:34:34.105Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-04T23:34:34.113Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-04T23:34:40.660Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-04T23:34:40.699Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-04T23:34:42.355Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.4 15.0 15.0)A
2025-11-04T23:34:52.660Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-04T23:35:04.656Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-04T23:35:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:35:28.656Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T23:36:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:37:12.937Z:USER:taskMaster.c:6582:Temperature: 25.6 C
2025-11-04T23:37:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:38:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:39:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:39:16.632Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-04T23:39:17.410Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-04T23:39:28.628Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-04T23:39:40.628Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-04T23:40:04.625Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-04T23:40:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:40:16.820Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=235.8V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T23:40:16.832Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T23:40:28.625Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-04T23:40:29.113Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-04T23:40:40.621Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-04T23:40:52.621Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-04T23:41:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:41:16.617Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T23:42:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:43:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:44:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:44:42.292Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T23:45:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-04T23:45:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:46:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:47:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:48:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:49:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:50:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:51:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:52:13.292Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-04T23:52:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:53:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:53:40.539Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-04T23:53:40.871Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-04T23:53:52.539Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-04T23:54:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:54:16.535Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-04T23:54:42.226Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-04T23:55:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:55:15.375Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000013, address 0x00013000 (1)
2025-11-04T23:55:15.386Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-04T23:55:16.722Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.1V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-04T23:55:16.734Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-04T23:56:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:57:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:57:16.566Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-04T23:57:16.988Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-04T23:57:28.566Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-04T23:57:40.566Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-04T23:58:04.562Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-04T23:58:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:58:40.558Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-04T23:58:40.808Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-04T23:58:52.558Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-04T23:59:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-04T23:59:16.554Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-05T00:00:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T00:00:07.597Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-05T00:00:07.605Z:INFO:db_chargingprofi:26: socket 0
2025-11-05T00:00:07.613Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-05T00:00:07.621Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-05T00:00:07.628Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-05T00:00:07.640Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-05T00:00:07.652Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-05T00:00:07.660Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-05T00:00:07.667Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-05T00:00:07.675Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-05T00:00:07.683Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-05T00:00:07.691Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-05T00:00:07.699Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-05T00:00:07.707Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-05T00:00:07.714Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-05T00:00:07.726Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-05T00:00:07.734Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-05T00:00:07.742Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-05T00:00:07.750Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-05T00:00:07.757Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-05T00:00:07.765Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-05T00:00:07.773Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-05T00:00:07.785Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-05T00:00:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:00:40.546Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-05T00:00:40.984Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.9% (14.3 A)
2025-11-05T00:00:52.542Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-05T00:01:04.542Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-05T00:01:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:01:28.539Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-05T00:02:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:03:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:04:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:04:42.164Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-05T00:05:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:06:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:07:13.699Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-05T00:07:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:08:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:09:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:10:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:10:16.628Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=234.9V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T00:10:16.640Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T00:10:52.531Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-05T00:10:52.980Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-05T00:11:04.531Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T00:11:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:11:16.527Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-05T00:11:40.527Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-05T00:12:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:12:40.519Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-05T00:12:41.039Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-05T00:12:52.519Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-05T00:13:04.515Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-05T00:13:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:13:28.515Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-05T00:14:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:14:42.101Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-05T00:15:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T00:15:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:16:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:17:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:18:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:19:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:20:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:21:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:21:28.515Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-05T00:21:29.214Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-05T00:21:40.511Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T00:21:52.511Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-05T00:22:04.511Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-05T00:22:04.562Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-05T00:22:14.054Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-05T00:22:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:22:16.507Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-05T00:22:28.507Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-05T00:22:52.503Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-05T00:23:04.503Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.6 due to current limit: Active-LoadBalancing
2025-11-05T00:23:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:23:16.503Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T00:23:28.500Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-05T00:23:52.500Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-05T00:24:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:24:42.039Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.0 15.0 15.0)A
2025-11-05T00:24:52.492Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-05T00:24:53.210Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-05T00:25:04.492Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-05T00:25:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:25:16.492Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-05T00:25:16.535Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=235.4V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T00:25:16.546Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T00:25:40.488Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-05T00:26:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:27:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:28:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:28:40.468Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-05T00:28:41.449Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-05T00:28:52.468Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T00:29:04.464Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-05T00:29:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:29:28.464Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-05T00:30:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T00:30:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:30:16.457Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-05T00:30:17.386Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-05T00:30:28.457Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-05T00:30:40.457Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-05T00:31:04.453Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-05T00:31:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:32:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:33:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:34:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:34:41.976Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-05T00:35:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:36:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:36:28.417Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-05T00:36:29.031Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-05T00:36:40.417Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T00:36:52.417Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-05T00:37:14.457Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-05T00:37:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:37:16.414Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-05T00:38:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:39:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:39:16.402Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-05T00:39:16.671Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-05T00:39:28.402Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-05T00:39:40.398Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-05T00:40:04.398Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-05T00:40:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:40:16.441Z:USER:taskMaster.c:6684:Socket #1: L1N=235.3V L2N=235.8V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T00:40:16.453Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T00:41:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:42:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:42:28.382Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->12.6 due to current limit: Active-LoadBalancing
2025-11-05T00:42:28.550Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-05T00:42:40.378Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->11.2 due to current limit: Active-LoadBalancing
2025-11-05T00:42:40.671Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.5% (11.1 A)
2025-11-05T00:42:52.378Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->10.3 due to current limit: Active-LoadBalancing
2025-11-05T00:42:52.789Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.1% (10.3 A)
2025-11-05T00:43:04.378Z:INFO:taskMain.c:5996:Socket #1: Active current 10.3->9.8 due to current limit: Active-LoadBalancing
2025-11-05T00:43:04.906Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.2% (9.7 A)
2025-11-05T00:43:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:43:16.375Z:INFO:taskMain.c:5996:Socket #1: Active current 9.8->9.5 due to current limit: Active-LoadBalancing
2025-11-05T00:43:28.375Z:INFO:taskMain.c:5996:Socket #1: Active current 9.5->9.3 due to current limit: Active-LoadBalancing
2025-11-05T00:43:40.375Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->9.2 due to current limit: Active-LoadBalancing
2025-11-05T00:44:04.371Z:INFO:taskMain.c:5996:Socket #1: Active current 9.1->9.1 due to current limit: Active-LoadBalancing
2025-11-05T00:44:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:44:41.910Z:INFO:active_lb.c:308:SMt:(7.0 1.0 1.0)A Free:(9.0 15.0 15.0)A ALB:(9.0 15.0 15.0)A
2025-11-05T00:45:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T00:45:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:46:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:46:16.355Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.6 due to current limit: Active-LoadBalancing
2025-11-05T00:46:16.789Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.3% (8.6 A)
2025-11-05T00:46:28.355Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.4 due to current limit: Active-LoadBalancing
2025-11-05T00:46:40.355Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.2 due to current limit: Active-LoadBalancing
2025-11-05T00:47:04.351Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->8.1 due to current limit: Active-LoadBalancing
2025-11-05T00:47:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:47:52.347Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->8.4 due to current limit: Active-LoadBalancing
2025-11-05T00:47:52.726Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.0% (8.4 A)
2025-11-05T00:48:04.347Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.6 due to current limit: Active-LoadBalancing
2025-11-05T00:48:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:48:16.343Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.8 due to current limit: Active-LoadBalancing
2025-11-05T00:48:40.343Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.9 due to current limit: Active-LoadBalancing
2025-11-05T00:49:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:50:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:51:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:52:14.863Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-05T00:52:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:53:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:54:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:54:41.847Z:INFO:active_lb.c:308:SMt:(7.0 1.0 1.0)A Free:(9.0 15.0 15.0)A ALB:(9.0 15.0 15.0)A
2025-11-05T00:55:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:55:16.343Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=233.9V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T00:55:16.355Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T00:56:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:56:15.089Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000014, address 0x00014000 (1)
2025-11-05T00:56:15.101Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-05T00:57:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:57:16.289Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.6 due to current limit: Active-LoadBalancing
2025-11-05T00:57:17.257Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.3% (8.6 A)
2025-11-05T00:57:28.285Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.4 due to current limit: Active-LoadBalancing
2025-11-05T00:57:40.285Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.2 due to current limit: Active-LoadBalancing
2025-11-05T00:58:04.281Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->8.1 due to current limit: Active-LoadBalancing
2025-11-05T00:58:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:58:52.277Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->8.4 due to current limit: Active-LoadBalancing
2025-11-05T00:58:53.199Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.0% (8.4 A)
2025-11-05T00:59:04.277Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.6 due to current limit: Active-LoadBalancing
2025-11-05T00:59:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T00:59:16.273Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.4 due to current limit: Active-LoadBalancing
2025-11-05T00:59:28.273Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.2 due to current limit: Active-LoadBalancing
2025-11-05T00:59:52.269Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->8.1 due to current limit: Active-LoadBalancing
2025-11-05T01:00:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T01:00:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:00:15.167Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-05T01:00:15.175Z:INFO:db_chargingprofi:26: socket 0
2025-11-05T01:00:15.183Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-05T01:00:15.191Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-05T01:00:15.199Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-05T01:00:15.207Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-05T01:00:15.218Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-05T01:00:15.226Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-05T01:00:15.238Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-05T01:00:15.246Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-05T01:00:15.253Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-05T01:00:15.261Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-05T01:00:15.269Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-05T01:00:15.277Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-05T01:00:15.285Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-05T01:00:15.292Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-05T01:00:15.304Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-05T01:00:15.312Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-05T01:00:15.320Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-05T01:00:15.328Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-05T01:00:15.335Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-05T01:00:15.343Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-05T01:00:15.351Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-05T01:00:40.265Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->8.4 due to current limit: Active-LoadBalancing
2025-11-05T01:00:41.257Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.0% (8.4 A)
2025-11-05T01:00:52.265Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.6 due to current limit: Active-LoadBalancing
2025-11-05T01:01:04.265Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.8 due to current limit: Active-LoadBalancing
2025-11-05T01:01:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:01:28.261Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.9 due to current limit: Active-LoadBalancing
2025-11-05T01:02:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:02:39.949Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-05T01:02:39.957Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-05T01:02:39.964Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=235.8V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T01:02:39.976Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T01:02:39.988Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-05T01:02:39.996Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-05T01:02:40.007Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-05T01:02:40.421Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-05T01:02:40.933Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-05T01:02:52.253Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->12.4 due to current limit: Active-LoadBalancing
2025-11-05T01:02:53.050Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-11-05T01:03:04.250Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->15.8 due to current limit: Active-LoadBalancing
2025-11-05T01:03:05.171Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.3% (15.8 A)
2025-11-05T01:03:09.996Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=234.1V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T01:03:10.007Z:USER:taskMaster.c:6720:Socket #1: I1=15.3A I2=15.4A I3=15.4A P=10.8kW Idc=0.7mA
2025-11-05T01:03:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:03:16.292Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-05T01:03:28.250Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->14.0 due to current limit: Active-LoadBalancing
2025-11-05T01:03:28.261Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->23.3)
2025-11-05T01:03:28.292Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-05T01:03:28.398Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.3% (14.0 A)
2025-11-05T01:03:37.496Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->2.7 due to current limit: Active-LoadBalancing
2025-11-05T01:03:37.511Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.3->23.3)
2025-11-05T01:03:37.523Z:WARNING:taskMain.c:4698:Socket #1: maximum current(2.75) < minimum current(6.00)
2025-11-05T01:03:37.542Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-05T01:03:37.558Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C1
2025-11-05T01:03:37.566Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-05T01:03:38.496Z:INFO:taskMain.c:6499:Socket #1: CPlow 6.3 V
2025-11-05T01:03:38.542Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-05T01:03:38.550Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-05T01:03:38.558Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-05T01:03:38.566Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-11-05T01:03:38.566Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-05T01:03:38.585Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-05T01:03:39.917Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-05T01:03:39.992Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=234.8V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T01:03:40.003Z:USER:taskMaster.c:6720:Socket #1: I1=6.7A I2=1.3A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T01:03:49.496Z:INFO:taskMain.c:5996:Socket #1: Active current 2.7->0.0 due to current limit: Active-LoadBalancing
2025-11-05T01:04:01.496Z:INFO:taskMain.c:5996:Socket #1: Active current 0.0->2.8 due to current limit: Active-LoadBalancing
2025-11-05T01:04:09.988Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=235.8V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T01:04:10.000Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T01:04:13.492Z:INFO:taskMain.c:5996:Socket #1: Active current 2.8->4.5 due to current limit: Active-LoadBalancing
2025-11-05T01:04:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:04:25.492Z:INFO:taskMain.c:5996:Socket #1: Active current 4.5->5.5 due to current limit: Active-LoadBalancing
2025-11-05T01:04:37.492Z:INFO:taskMain.c:5996:Socket #1: Active current 5.5->6.1 due to current limit: Active-LoadBalancing
2025-11-05T01:04:37.535Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-05T01:04:37.546Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-05T01:04:37.554Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-05T01:04:38.132Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-05T01:04:38.140Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.1% (6.1 A)
2025-11-05T01:04:38.535Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-05T01:04:38.542Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-05T01:04:38.554Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=235.8V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T01:04:38.566Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T01:04:38.578Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-05T01:04:38.585Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-05T01:04:38.593Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-05T01:04:39.140Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-05T01:04:39.539Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-05T01:04:41.785Z:INFO:active_lb.c:308:SMt:(9.0 1.0 1.0)A Free:(7.0 15.0 15.0)A ALB:(6.1 14.4 14.2)A
2025-11-05T01:04:49.488Z:INFO:taskMain.c:5996:Socket #1: Active current 6.1->8.9 due to current limit: Active-LoadBalancing
2025-11-05T01:04:49.640Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.7% (8.8 A)
2025-11-05T01:05:01.488Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->9.1 due to current limit: Active-LoadBalancing
2025-11-05T01:05:08.582Z:USER:taskMaster.c:6684:Socket #1: L1N=233.4V L2N=234.9V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T01:05:08.593Z:USER:taskMaster.c:6720:Socket #1: I1=8.7A I2=8.7A I3=8.7A P=6.1kW Idc=0.7mA
2025-11-05T01:05:13.488Z:INFO:taskMain.c:5996:Socket #1: Active current 9.1->9.4 due to current limit: Active-LoadBalancing
2025-11-05T01:05:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:05:25.484Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->8.4 due to current limit: Active-LoadBalancing
2025-11-05T01:05:25.500Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (15.5->14.0)
2025-11-05T01:05:25.996Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.0% (8.4 A)
2025-11-05T01:05:37.484Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->7.5 due to current limit: Active-LoadBalancing
2025-11-05T01:05:37.496Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (14.0->12.5)
2025-11-05T01:05:38.113Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.5% (7.5 A)
2025-11-05T01:05:38.523Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-05T01:05:38.578Z:USER:taskMaster.c:6684:Socket #1: L1N=233.4V L2N=235.3V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T01:05:38.589Z:USER:taskMaster.c:6720:Socket #1: I1=8.1A I2=8.1A I3=8.0A P=5.6kW Idc=0.7mA
2025-11-05T01:05:49.484Z:INFO:taskMain.c:5996:Socket #1: Active current 7.5->7.0 due to current limit: Active-LoadBalancing
2025-11-05T01:05:49.496Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (12.5->11.6)
2025-11-05T01:05:50.234Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.6% (7.0 A)
2025-11-05T01:06:01.480Z:INFO:taskMain.c:5996:Socket #1: Active current 7.0->6.9 due to current limit: Active-LoadBalancing
2025-11-05T01:06:01.496Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.6->11.4)
2025-11-05T01:06:08.574Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=235.4V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T01:06:08.585Z:USER:taskMaster.c:6720:Socket #1: I1=6.5A I2=6.6A I3=6.4A P=4.5kW Idc=0.7mA
2025-11-05T01:06:13.480Z:INFO:taskMain.c:5996:Socket #1: Active current 6.9->6.7 due to current limit: Active-LoadBalancing
2025-11-05T01:06:13.492Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.4->11.1)
2025-11-05T01:06:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:06:25.480Z:INFO:taskMain.c:5996:Socket #1: Active current 6.7->6.6 due to current limit: Active-LoadBalancing
2025-11-05T01:06:25.492Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (11.1->10.9)
2025-11-05T01:06:37.480Z:INFO:taskMain.c:5996:Socket #1: Active current 6.6->6.8 due to current limit: Active-LoadBalancing
2025-11-05T01:06:38.574Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=235.6V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T01:06:38.585Z:USER:taskMaster.c:6720:Socket #1: I1=6.1A I2=6.3A I3=6.2A P=4.3kW Idc=0.7mA
2025-11-05T01:06:49.476Z:INFO:taskMain.c:5996:Socket #1: Active current 6.8->7.1 due to current limit: Active-LoadBalancing
2025-11-05T01:07:01.476Z:INFO:taskMain.c:5996:Socket #1: Active current 7.1->7.3 due to current limit: Active-LoadBalancing
2025-11-05T01:07:08.570Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=235.1V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T01:07:08.585Z:USER:taskMaster.c:6720:Socket #1: I1=6.9A I2=7.1A I3=7.0A P=4.9kW Idc=0.7mA
2025-11-05T01:07:09.019Z:INFO:EVCapabilities.c:24:Socket #1 EV: #phases supported: 3
2025-11-05T01:07:13.476Z:INFO:taskMain.c:5996:Socket #1: Active current 7.3->7.6 due to current limit: Active-LoadBalancing
2025-11-05T01:07:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:07:15.218Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-05T01:07:25.472Z:INFO:taskMain.c:5996:Socket #1: Active current 7.6->11.1 due to current limit: Active-LoadBalancing
2025-11-05T01:07:26.171Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.4% (11.0 A)
2025-11-05T01:07:37.472Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:07:38.292Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-05T01:07:38.566Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.9V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T01:07:38.578Z:USER:taskMaster.c:6720:Socket #1: I1=10.7A I2=10.7A I3=10.6A P=7.5kW Idc=0.7mA
2025-11-05T01:07:49.472Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->15.9 due to current limit: ChargingProfile
2025-11-05T01:07:49.515Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-05T01:07:50.410Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-05T01:08:08.562Z:USER:taskMaster.c:6684:Socket #1: L1N=233.4V L2N=234.3V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T01:08:08.574Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.6A I3=15.6A P=10.9kW Idc=0.7mA
2025-11-05T01:08:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:08:37.464Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.4 due to current limit: Active-LoadBalancing
2025-11-05T01:08:37.480Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->25.6)
2025-11-05T01:08:37.507Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-05T01:08:37.875Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.6% (15.4 A)
2025-11-05T01:08:38.558Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.4V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T01:08:38.570Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-11-05T01:08:49.464Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:08:49.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.6->24.7)
2025-11-05T01:08:49.996Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.7% (14.8 A)
2025-11-05T01:09:01.464Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:09:01.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-05T01:09:08.558Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.6V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T01:09:08.570Z:USER:taskMaster.c:6720:Socket #1: I1=14.3A I2=14.3A I3=14.2A P=10.0kW Idc=0.7mA
2025-11-05T01:09:13.460Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:09:13.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-05T01:09:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:09:25.460Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:09:25.472Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-05T01:09:37.460Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:09:38.554Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=234.7V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T01:09:38.566Z:USER:taskMaster.c:6720:Socket #1: I1=13.9A I2=14.0A I3=13.9A P=9.8kW Idc=0.7mA
2025-11-05T01:09:38.578Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-05T01:09:49.457Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:10:01.457Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-05T01:10:13.457Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:10:13.468Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-05T01:10:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:10:25.453Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:10:25.468Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-05T01:10:37.453Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:10:37.464Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-05T01:10:49.453Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:10:49.464Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-05T01:11:01.449Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-05T01:11:01.464Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.6)
2025-11-05T01:11:13.449Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.0 due to current limit: Active-LoadBalancing
2025-11-05T01:11:13.460Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.6->23.3)
2025-11-05T01:11:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:11:25.449Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:11:37.445Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:11:49.445Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:11:49.753Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.8% (14.9 A)
2025-11-05T01:12:01.445Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-05T01:12:13.441Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.4 due to current limit: Active-LoadBalancing
2025-11-05T01:12:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:12:25.441Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.2 due to current limit: Active-LoadBalancing
2025-11-05T01:12:25.453Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.6->25.4)
2025-11-05T01:12:37.441Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.1 due to current limit: Active-LoadBalancing
2025-11-05T01:12:37.453Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-05T01:12:49.437Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:12:49.453Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-05T01:13:01.437Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:13:01.449Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-05T01:13:13.437Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:13:13.449Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-05T01:13:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:13:25.433Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:13:25.449Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-05T01:13:37.433Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:13:37.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-05T01:13:49.433Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-05T01:13:49.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.4)
2025-11-05T01:14:01.433Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:14:13.429Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:14:14.171Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.4% (14.6 A)
2025-11-05T01:14:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:14:25.429Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:14:37.429Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:14:37.441Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.6)
2025-11-05T01:14:41.722Z:INFO:active_lb.c:308:SMt:(15.0 16.0 15.0)A Free:(1.0 0.0 1.0)A ALB:(15.4 14.8 15.6)A
2025-11-05T01:14:49.425Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:14:49.437Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-05T01:15:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T01:15:01.425Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:15:01.437Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-05T01:15:13.425Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:15:13.437Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-05T01:15:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:15:25.421Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:15:37.421Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:15:49.421Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:15:49.433Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-05T01:16:01.417Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:16:01.433Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->24.0)
2025-11-05T01:16:13.417Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:16:13.429Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.7)
2025-11-05T01:16:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:16:25.417Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:16:37.414Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:16:49.414Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:16:49.425Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-05T01:17:01.414Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:17:01.425Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-05T01:17:13.410Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:17:13.425Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.7)
2025-11-05T01:17:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:17:25.410Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:17:37.410Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:17:49.406Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:17:49.421Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-05T01:18:01.406Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:18:01.417Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-05T01:18:13.406Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:18:13.417Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.7)
2025-11-05T01:18:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:18:25.402Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:18:37.402Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:18:49.402Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:18:49.414Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-05T01:19:01.398Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:19:01.414Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-05T01:19:13.398Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:19:13.410Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-05T01:19:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:19:25.398Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-05T01:19:25.410Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-05T01:19:37.394Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:19:49.394Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:20:01.394Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:20:13.390Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:20:13.406Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-05T01:20:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:20:25.390Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:20:25.402Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-05T01:20:37.390Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:20:37.402Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-05T01:20:49.390Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:20:49.402Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-05T01:21:01.386Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-05T01:21:01.398Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-05T01:21:13.386Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:21:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:21:25.386Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:21:37.382Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:21:49.382Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:21:49.394Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-05T01:22:01.382Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:22:01.394Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-05T01:22:13.378Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:22:13.390Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-05T01:22:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:22:15.574Z:USER:taskMaster.c:6582:Temperature: 27.8 C
2025-11-05T01:22:25.378Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:22:25.390Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-05T01:22:37.378Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-05T01:22:37.390Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-05T01:22:49.375Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:23:01.375Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:23:13.375Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:23:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:23:25.371Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:23:25.386Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-05T01:23:37.371Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:23:37.382Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-05T01:23:49.371Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:23:49.382Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-05T01:24:01.367Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-05T01:24:01.382Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-05T01:24:13.367Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:24:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:24:25.367Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:24:37.363Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:24:38.457Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.8V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T01:24:38.472Z:USER:taskMaster.c:6720:Socket #1: I1=14.1A I2=14.2A I3=14.2A P=9.9kW Idc=0.7mA
2025-11-05T01:24:41.656Z:INFO:active_lb.c:308:SMt:(15.0 16.0 15.0)A Free:(1.0 0.0 1.0)A ALB:(15.6 14.8 15.4)A
2025-11-05T01:24:49.363Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:24:49.375Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-05T01:25:01.363Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:25:01.375Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-05T01:25:13.359Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:25:13.375Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-05T01:25:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:25:25.359Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-05T01:25:25.371Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-05T01:25:37.359Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:25:49.355Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:26:01.355Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:26:13.355Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:26:13.367Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-05T01:26:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:26:25.351Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:26:25.367Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-05T01:26:37.351Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:26:37.363Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.9)
2025-11-05T01:26:49.351Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-05T01:26:49.363Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.6)
2025-11-05T01:27:01.347Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:27:13.347Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:27:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:27:25.347Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:27:25.359Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-05T01:27:37.343Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:27:37.359Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-05T01:27:49.343Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-05T01:27:49.355Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.6)
2025-11-05T01:28:01.343Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.0 due to current limit: Active-LoadBalancing
2025-11-05T01:28:01.355Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.6->23.3)
2025-11-05T01:28:13.343Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.2 due to current limit: Active-LoadBalancing
2025-11-05T01:28:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:28:25.339Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:28:37.339Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:28:49.339Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:28:49.351Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-05T01:29:01.335Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:29:01.347Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-05T01:29:13.335Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-05T01:29:13.347Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.6)
2025-11-05T01:29:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:29:25.335Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:29:37.332Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:29:49.332Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-05T01:30:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T01:30:01.332Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:30:01.343Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-05T01:30:13.328Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:30:13.343Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-05T01:30:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:30:25.328Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:30:25.339Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-05T01:30:37.328Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:30:49.324Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-05T01:31:01.324Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:31:01.335Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-05T01:31:13.324Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:31:13.335Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-05T01:31:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:31:25.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:31:25.335Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-05T01:31:37.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:31:37.332Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-05T01:31:49.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:31:49.332Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.7)
2025-11-05T01:32:01.316Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-05T01:32:01.332Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.7->23.4)
2025-11-05T01:32:13.316Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:32:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:32:25.316Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:32:37.312Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:32:49.312Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.1 due to current limit: Active-LoadBalancing
2025-11-05T01:32:50.093Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.1% (15.1 A)
2025-11-05T01:33:01.312Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.3 due to current limit: Active-LoadBalancing
2025-11-05T01:33:13.308Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.2 due to current limit: Active-LoadBalancing
2025-11-05T01:33:13.324Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->25.3)
2025-11-05T01:33:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:33:25.308Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-05T01:33:25.320Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-05T01:33:37.308Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:33:37.320Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-05T01:33:49.304Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:33:49.320Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-05T01:34:01.304Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:34:01.316Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-05T01:34:13.304Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:34:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:34:25.300Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-05T01:34:27.601Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-05T01:34:27.871Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-05T01:34:33.343Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-05T01:34:33.355Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-05T01:34:37.300Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:34:37.312Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-05T01:34:41.593Z:INFO:active_lb.c:308:SMt:(15.0 16.0 15.0)A Free:(1.0 0.0 1.0)A ALB:(15.4 14.9 15.4)A
2025-11-05T01:34:49.300Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:34:49.312Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-05T01:35:01.296Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:35:01.312Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-05T01:35:13.296Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:35:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:35:25.296Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-05T01:35:37.296Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-05T01:35:49.292Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-05T01:35:49.304Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-05T01:36:01.292Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:36:01.304Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-05T01:36:13.292Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:36:13.304Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-05T01:36:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:36:25.289Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:36:25.300Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-05T01:36:37.289Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:36:49.289Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-05T01:37:01.285Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:37:01.296Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-05T01:37:13.285Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:37:13.296Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.6)
2025-11-05T01:37:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:37:15.929Z:USER:taskMaster.c:6582:Temperature: 29.8 C
2025-11-05T01:37:25.285Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:37:25.296Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-05T01:37:37.281Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:37:49.281Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-05T01:38:01.281Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:38:01.292Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-05T01:38:13.277Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:38:13.292Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.6)
2025-11-05T01:38:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:38:25.277Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:38:25.289Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-05T01:38:37.277Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:38:49.273Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-05T01:39:01.273Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-05T01:39:13.273Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-05T01:39:13.285Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.2)
2025-11-05T01:39:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:39:25.269Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-05T01:39:25.285Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-05T01:39:37.269Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:39:37.281Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-05T01:39:38.363Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.7V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T01:39:38.375Z:USER:taskMaster.c:6720:Socket #1: I1=14.5A I2=14.5A I3=14.5A P=10.2kW Idc=0.7mA
2025-11-05T01:39:49.269Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:39:49.281Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-05T01:40:01.265Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:40:13.265Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-05T01:40:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:40:25.265Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:40:25.277Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-05T01:40:37.261Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:40:37.277Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-05T01:40:49.261Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:40:49.273Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-05T01:41:01.261Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:41:13.257Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-05T01:41:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:41:25.257Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:41:25.269Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-05T01:41:37.257Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:41:37.269Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-05T01:41:49.253Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:41:49.269Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-05T01:42:01.253Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:42:13.253Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-05T01:42:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:42:25.250Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:42:25.265Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-05T01:42:37.250Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:42:37.261Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-05T01:42:49.250Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:42:49.261Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-05T01:43:01.246Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:43:01.261Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.1)
2025-11-05T01:43:13.246Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:43:13.257Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.7)
2025-11-05T01:43:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:43:25.246Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-05T01:43:25.257Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.7->23.4)
2025-11-05T01:43:37.246Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:43:49.242Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:44:01.242Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:44:13.242Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.2 due to current limit: Active-LoadBalancing
2025-11-05T01:44:13.253Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->23.6)
2025-11-05T01:44:13.808Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.6% (14.2 A)
2025-11-05T01:44:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:44:25.238Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->13.6 due to current limit: Active-LoadBalancing
2025-11-05T01:44:25.250Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.6->22.6)
2025-11-05T01:44:25.929Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-05T01:44:37.238Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-05T01:44:37.250Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.6->22.3)
2025-11-05T01:44:41.531Z:INFO:active_lb.c:308:SMt:(16.0 15.0 14.0)A Free:(0.0 1.0 2.0)A ALB:(13.4 14.4 15.0)A
2025-11-05T01:44:49.238Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-05T01:45:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T01:45:01.234Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-05T01:45:13.234Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->14.1 due to current limit: Active-LoadBalancing
2025-11-05T01:45:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:45:25.234Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:45:37.230Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:45:37.632Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.9% (14.9 A)
2025-11-05T01:45:49.230Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.2 due to current limit: Active-LoadBalancing
2025-11-05T01:46:01.230Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-05T01:46:01.242Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-05T01:46:13.226Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:46:13.242Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-05T01:46:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:46:25.226Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:46:25.238Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-05T01:46:37.226Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:46:37.238Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-05T01:46:49.222Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:46:49.238Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-05T01:47:01.273Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:47:13.269Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:47:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:47:25.269Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-05T01:47:37.269Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-05T01:47:37.281Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-05T01:47:49.265Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:47:49.281Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-05T01:48:01.265Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:48:01.277Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-05T01:48:13.265Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:48:13.277Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-05T01:48:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:48:25.261Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:48:37.261Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-05T01:48:49.261Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:48:49.273Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-05T01:49:01.261Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:49:01.273Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-05T01:49:13.257Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:49:13.269Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-05T01:49:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:49:25.257Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:49:37.257Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-05T01:49:49.253Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:49:49.265Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-05T01:50:01.253Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:50:01.265Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-05T01:50:13.253Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:50:13.265Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-05T01:50:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:50:25.250Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:50:25.265Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->24.0)
2025-11-05T01:50:37.250Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:50:49.250Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:51:01.246Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-05T01:51:13.246Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-05T01:51:13.257Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-05T01:51:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:51:25.246Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:51:25.257Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-05T01:51:37.242Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:51:37.257Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-05T01:51:49.242Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:51:49.253Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-05T01:52:01.242Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:52:13.238Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-05T01:52:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:52:16.332Z:USER:taskMaster.c:6582:Temperature: 30.9 C
2025-11-05T01:52:25.238Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:52:25.250Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-05T01:52:37.238Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:52:37.250Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-05T01:52:49.234Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:52:49.250Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-05T01:53:01.234Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:53:01.246Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-05T01:53:13.234Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:53:13.246Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-05T01:53:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:53:25.230Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:53:37.230Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:53:49.230Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-05T01:54:01.226Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:54:01.242Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-05T01:54:13.226Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:54:13.238Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-05T01:54:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:54:25.226Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:54:25.238Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-05T01:54:37.222Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:54:37.238Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-05T01:54:38.269Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.8V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T01:54:38.281Z:USER:taskMaster.c:6720:Socket #1: I1=14.1A I2=14.2A I3=14.1A P=9.9kW Idc=0.7mA
2025-11-05T01:54:41.468Z:INFO:active_lb.c:308:SMt:(15.0 16.0 15.0)A Free:(1.0 0.0 1.0)A ALB:(15.3 14.4 15.3)A
2025-11-05T01:54:49.222Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:55:01.222Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-05T01:55:13.218Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-05T01:55:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:55:25.218Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.1 due to current limit: Active-LoadBalancing
2025-11-05T01:55:25.230Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-05T01:55:37.218Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:55:37.230Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-05T01:55:49.214Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:55:49.230Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-05T01:55:53.890Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-05T01:55:54.187Z:INFO:taskCANopen.c:1787:Updated object 0x2249, 9 bytes
2025-11-05T01:56:01.214Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:56:01.226Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-05T01:56:13.214Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:56:13.226Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-05T01:56:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:56:25.210Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:56:37.210Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-05T01:56:49.210Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:56:49.222Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.4)
2025-11-05T01:57:01.207Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:57:01.222Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-05T01:57:13.207Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:57:13.218Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-05T01:57:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:57:15.601Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000015, address 0x00015000 (1)
2025-11-05T01:57:15.613Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-05T01:57:25.207Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->13.7 due to current limit: Active-LoadBalancing
2025-11-05T01:57:25.218Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->22.9)
2025-11-05T01:57:25.554Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.9% (13.7 A)
2025-11-05T01:57:37.207Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.2 due to current limit: Active-LoadBalancing
2025-11-05T01:57:37.218Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.9->21.9)
2025-11-05T01:57:37.675Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.9% (13.1 A)
2025-11-05T01:57:49.203Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.0 due to current limit: Active-LoadBalancing
2025-11-05T01:57:49.214Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.9->21.7)
2025-11-05T01:58:01.203Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.7 due to current limit: Active-LoadBalancing
2025-11-05T01:58:01.914Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.8% (13.7 A)
2025-11-05T01:58:13.203Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:58:14.031Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.8% (14.3 A)
2025-11-05T01:58:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:58:25.199Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:58:37.199Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-05T01:58:49.199Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-05T01:58:49.210Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-05T01:59:01.195Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T01:59:01.207Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-05T01:59:13.195Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-05T01:59:13.207Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.7)
2025-11-05T01:59:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T01:59:25.195Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-05T01:59:37.191Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-05T01:59:37.851Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.7% (14.8 A)
2025-11-05T01:59:49.191Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-05T02:00:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T02:00:01.191Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-05T02:00:01.203Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-05T02:00:13.187Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->13.7 due to current limit: Active-LoadBalancing
2025-11-05T02:00:13.203Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->22.8)
2025-11-05T02:00:13.214Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.8% (13.7 A)
2025-11-05T02:00:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:00:22.683Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-05T02:00:22.695Z:INFO:db_chargingprofi:26: socket 0
2025-11-05T02:00:22.703Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-05T02:00:22.710Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-05T02:00:22.718Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-05T02:00:22.726Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-05T02:00:22.738Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-05T02:00:22.746Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-05T02:00:22.757Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-05T02:00:22.765Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-05T02:00:22.773Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-05T02:00:22.781Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-05T02:00:22.789Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-05T02:00:22.796Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-05T02:00:22.804Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-05T02:00:22.816Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-05T02:00:22.824Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-05T02:00:22.832Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-05T02:00:22.839Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-05T02:00:22.847Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-05T02:00:22.855Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-05T02:00:22.863Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-05T02:00:22.875Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-05T02:00:25.187Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->12.3 due to current limit: Active-LoadBalancing
2025-11-05T02:00:25.199Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.8->20.5)
2025-11-05T02:00:25.328Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.5% (12.3 A)
2025-11-05T02:00:37.187Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:00:37.199Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.5->18.9)
2025-11-05T02:00:37.445Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.9% (11.3 A)
2025-11-05T02:00:49.183Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->10.8 due to current limit: Active-LoadBalancing
2025-11-05T02:00:49.199Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->17.9)
2025-11-05T02:00:49.566Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.9% (10.7 A)
2025-11-05T02:01:01.183Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->11.0 due to current limit: Active-LoadBalancing
2025-11-05T02:01:03.410Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-05T02:01:03.707Z:INFO:taskCANopen.c:1787:Updated object 0x2249, 9 bytes
2025-11-05T02:01:13.183Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-05T02:01:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:01:21.976Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-05T02:01:21.984Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-05T02:01:21.992Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-05T02:01:22.003Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-05T02:01:22.890Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-05T02:01:23.000Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-05T02:01:25.179Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->7.1 due to current limit: Active-LoadBalancing
2025-11-05T02:01:26.031Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.9% (7.1 A)
2025-11-05T02:01:37.179Z:INFO:taskMain.c:5996:Socket #1: Active current 7.1->4.7 due to current limit: Active-LoadBalancing
2025-11-05T02:01:37.191Z:WARNING:taskMain.c:4698:Socket #1: maximum current(4.69) < minimum current(6.00)
2025-11-05T02:01:37.222Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-05T02:01:37.234Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-05T02:01:37.242Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-05T02:01:38.148Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-05T02:01:38.218Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-11-05T02:01:38.218Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-05T02:01:49.179Z:INFO:taskMain.c:5996:Socket #1: Active current 4.7->7.2 due to current limit: Active-LoadBalancing
2025-11-05T02:01:49.222Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-05T02:01:49.230Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-05T02:01:49.242Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-05T02:01:49.328Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-05T02:01:50.226Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-05T02:02:01.175Z:INFO:taskMain.c:5996:Socket #1: Active current 7.2->8.7 due to current limit: Active-LoadBalancing
2025-11-05T02:02:01.335Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.5% (8.7 A)
2025-11-05T02:02:13.175Z:INFO:taskMain.c:5996:Socket #1: Active current 8.7->9.6 due to current limit: Active-LoadBalancing
2025-11-05T02:02:13.457Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.0% (9.6 A)
2025-11-05T02:02:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:02:19.269Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-05T02:02:19.277Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-05T02:02:19.515Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-05T02:02:19.523Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-05T02:02:20.265Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-05T02:02:23.269Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-05T02:02:23.292Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-05T02:02:23.300Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-05T02:02:23.769Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-05T02:02:23.777Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-05T02:02:24.304Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-05T02:02:24.792Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-05T02:02:25.175Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->10.2 due to current limit: Active-LoadBalancing
2025-11-05T02:02:25.804Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.9% (10.1 A)
2025-11-05T02:02:37.171Z:INFO:taskMain.c:5996:Socket #1: Active current 10.2->10.5 due to current limit: Active-LoadBalancing
2025-11-05T02:02:37.921Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.5% (10.5 A)
2025-11-05T02:02:49.171Z:INFO:taskMain.c:5996:Socket #1: Active current 10.5->10.7 due to current limit: Active-LoadBalancing
2025-11-05T02:03:01.171Z:INFO:taskMain.c:5996:Socket #1: Active current 10.7->10.8 due to current limit: Active-LoadBalancing
2025-11-05T02:03:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:03:25.167Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->10.9 due to current limit: Active-LoadBalancing
2025-11-05T02:04:09.156Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-05T02:04:09.167Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-05T02:04:09.175Z:USER:taskMaster.c:6684:Socket #1: L1N=236.6V L2N=237.0V L3N=236.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:04:09.187Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T02:04:09.199Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-05T02:04:09.207Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-05T02:04:09.214Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-05T02:04:09.824Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-05T02:04:10.171Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-05T02:04:13.164Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.6 due to current limit: Active-LoadBalancing
2025-11-05T02:04:13.203Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.3% (11.6 A)
2025-11-05T02:04:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:04:25.160Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->15.8 due to current limit: Active-LoadBalancing
2025-11-05T02:04:25.320Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.3% (15.8 A)
2025-11-05T02:04:37.160Z:INFO:taskMain.c:5996:Socket #1: Active current 15.8->15.6 due to current limit: Active-LoadBalancing
2025-11-05T02:04:37.171Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.3->25.9)
2025-11-05T02:04:39.203Z:USER:taskMaster.c:6684:Socket #1: L1N=235.1V L2N=235.6V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:04:39.214Z:USER:taskMaster.c:6720:Socket #1: I1=15.3A I2=15.3A I3=15.2A P=10.7kW Idc=0.7mA
2025-11-05T02:04:41.402Z:INFO:active_lb.c:308:SMt:(12.0 12.0 16.0)A Free:(4.0 4.0 0.0)A ALB:(19.3 19.3 15.6)A
2025-11-05T02:04:49.160Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->13.8 due to current limit: Active-LoadBalancing
2025-11-05T02:04:49.171Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.9->22.9)
2025-11-05T02:04:49.558Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.9% (13.7 A)
2025-11-05T02:05:01.156Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->12.0 due to current limit: Active-LoadBalancing
2025-11-05T02:05:01.171Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.9->20.0)
2025-11-05T02:05:01.679Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.0% (12.0 A)
2025-11-05T02:05:09.156Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-05T02:05:09.203Z:USER:taskMaster.c:6684:Socket #1: L1N=235.7V L2N=236.1V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:05:09.214Z:USER:taskMaster.c:6720:Socket #1: I1=11.6A I2=11.7A I3=11.6A P=8.2kW Idc=0.7mA
2025-11-05T02:05:13.156Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->10.3 due to current limit: Active-LoadBalancing
2025-11-05T02:05:13.167Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.0->17.0)
2025-11-05T02:05:13.796Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.0% (10.2 A)
2025-11-05T02:05:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:05:25.156Z:INFO:taskMain.c:5996:Socket #1: Active current 10.3->10.1 due to current limit: Active-LoadBalancing
2025-11-05T02:05:25.167Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (17.0->16.8)
2025-11-05T02:05:37.152Z:INFO:taskMain.c:5996:Socket #1: Active current 10.1->10.8 due to current limit: Active-LoadBalancing
2025-11-05T02:05:38.035Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.9% (10.7 A)
2025-11-05T02:05:39.199Z:USER:taskMaster.c:6684:Socket #1: L1N=235.8V L2N=236.1V L3N=235.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:05:39.210Z:USER:taskMaster.c:6720:Socket #1: I1=10.2A I2=10.2A I3=10.2A P=7.3kW Idc=0.7mA
2025-11-05T02:05:49.152Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:05:50.152Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.0% (11.4 A)
2025-11-05T02:06:01.152Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-05T02:06:09.195Z:USER:taskMaster.c:6684:Socket #1: L1N=235.7V L2N=236.0V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:06:09.207Z:USER:taskMaster.c:6720:Socket #1: I1=11.3A I2=11.3A I3=11.3A P=8.0kW Idc=0.7mA
2025-11-05T02:06:13.148Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.9 due to current limit: Active-LoadBalancing
2025-11-05T02:06:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:06:18.542Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-05T02:06:18.554Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-05T02:06:18.562Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-05T02:06:18.570Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-05T02:06:19.441Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-05T02:06:19.578Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-05T02:06:25.148Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->7.1 due to current limit: Active-LoadBalancing
2025-11-05T02:06:25.640Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.9% (7.1 A)
2025-11-05T02:06:37.148Z:INFO:taskMain.c:5996:Socket #1: Active current 7.1->8.7 due to current limit: Active-LoadBalancing
2025-11-05T02:06:37.757Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.4% (8.6 A)
2025-11-05T02:06:39.191Z:USER:taskMaster.c:6684:Socket #1: L1N=237.0V L2N=237.3V L3N=237.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:06:39.203Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T02:06:49.148Z:INFO:taskMain.c:5996:Socket #1: Active current 8.7->9.6 due to current limit: Active-LoadBalancing
2025-11-05T02:06:49.875Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.0% (9.6 A)
2025-11-05T02:07:01.144Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->10.2 due to current limit: Active-LoadBalancing
2025-11-05T02:07:01.996Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.9% (10.1 A)
2025-11-05T02:07:09.187Z:USER:taskMaster.c:6684:Socket #1: L1N=237.2V L2N=237.2V L3N=237.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:07:09.203Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T02:07:13.144Z:INFO:taskMain.c:5996:Socket #1: Active current 10.2->10.5 due to current limit: Active-LoadBalancing
2025-11-05T02:07:14.113Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.5% (10.5 A)
2025-11-05T02:07:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:07:16.738Z:USER:taskMaster.c:6582:Temperature: 31.2 C
2025-11-05T02:07:25.144Z:INFO:taskMain.c:5996:Socket #1: Active current 10.5->10.7 due to current limit: Active-LoadBalancing
2025-11-05T02:07:37.140Z:INFO:taskMain.c:5996:Socket #1: Active current 10.7->10.8 due to current limit: Active-LoadBalancing
2025-11-05T02:07:39.183Z:USER:taskMaster.c:6684:Socket #1: L1N=237.1V L2N=237.0V L3N=237.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:07:39.199Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T02:08:01.140Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->10.9 due to current limit: Active-LoadBalancing
2025-11-05T02:08:09.183Z:USER:taskMaster.c:6684:Socket #1: L1N=237.3V L2N=237.1V L3N=237.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:08:09.195Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T02:08:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:08:39.179Z:USER:taskMaster.c:6684:Socket #1: L1N=237.0V L2N=236.9V L3N=237.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:08:39.191Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T02:09:09.175Z:USER:taskMaster.c:6684:Socket #1: L1N=237.0V L2N=236.9V L3N=237.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:09:09.187Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T02:09:09.199Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-05T02:09:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:10:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:11:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:12:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:13:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:14:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:14:41.339Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-05T02:15:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T02:15:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:16:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:17:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:18:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:19:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:20:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:21:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:22:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:22:17.093Z:USER:taskMaster.c:6582:Temperature: 29.6 C
2025-11-05T02:23:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:24:09.082Z:USER:taskMaster.c:6684:Socket #1: L1N=237.0V L2N=237.1V L3N=236.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:24:09.093Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T02:24:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:24:41.277Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-05T02:25:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:26:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:27:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:28:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:29:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:30:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T02:30:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:31:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:32:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:33:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:34:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:34:41.214Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-05T02:35:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:36:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:37:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:37:17.496Z:USER:taskMaster.c:6582:Temperature: 28.0 C
2025-11-05T02:38:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:39:08.984Z:USER:taskMaster.c:6684:Socket #1: L1N=237.8V L2N=237.9V L3N=237.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:39:09.000Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T02:39:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:39:19.035Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-05T02:39:19.042Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-05T02:39:19.054Z:USER:taskMaster.c:6684:Socket #1: L1N=237.8V L2N=238.0V L3N=237.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:39:19.066Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T02:39:19.074Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-05T02:39:19.085Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-05T02:39:19.093Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-05T02:39:19.980Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-05T02:39:20.019Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-05T02:39:24.941Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->15.2 due to current limit: Active-LoadBalancing
2025-11-05T02:39:25.070Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.3% (15.2 A)
2025-11-05T02:39:36.937Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.9 due to current limit: ChargingProfile
2025-11-05T02:39:36.984Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-05T02:39:37.187Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-05T02:39:49.082Z:USER:taskMaster.c:6684:Socket #1: L1N=236.0V L2N=236.2V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:39:49.093Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=11.0kW Idc=0.7mA
2025-11-05T02:40:00.937Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->14.2 due to current limit: Active-LoadBalancing
2025-11-05T02:40:00.949Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->23.6)
2025-11-05T02:40:00.980Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-05T02:40:01.425Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.6% (14.2 A)
2025-11-05T02:40:12.933Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->12.4 due to current limit: Active-LoadBalancing
2025-11-05T02:40:12.949Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.6->20.7)
2025-11-05T02:40:13.542Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-11-05T02:40:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:40:19.003Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-05T02:40:19.078Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=236.6V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:40:19.089Z:USER:taskMaster.c:6720:Socket #1: I1=12.1A I2=12.1A I3=12.1A P=8.6kW Idc=0.7mA
2025-11-05T02:40:24.933Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->11.5 due to current limit: Active-LoadBalancing
2025-11-05T02:40:24.945Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.7->19.1)
2025-11-05T02:40:25.664Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.1% (11.5 A)
2025-11-05T02:40:36.933Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->10.9 due to current limit: Active-LoadBalancing
2025-11-05T02:40:36.945Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.1)
2025-11-05T02:40:37.781Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.1% (10.9 A)
2025-11-05T02:40:48.929Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.1 due to current limit: Active-LoadBalancing
2025-11-05T02:40:49.074Z:USER:taskMaster.c:6684:Socket #1: L1N=236.2V L2N=236.7V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:40:49.085Z:USER:taskMaster.c:6720:Socket #1: I1=10.4A I2=10.5A I3=10.4A P=7.4kW Idc=0.7mA
2025-11-05T02:41:00.929Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-05T02:41:12.929Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.6 due to current limit: Active-LoadBalancing
2025-11-05T02:41:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:41:19.070Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=236.5V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:41:19.085Z:USER:taskMaster.c:6720:Socket #1: I1=11.1A I2=11.2A I3=11.1A P=7.9kW Idc=0.7mA
2025-11-05T02:41:24.925Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-05T02:41:36.925Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T02:41:36.937Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.3)
2025-11-05T02:41:48.925Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:41:48.937Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-05T02:41:49.070Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=236.8V L3N=236.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:41:49.082Z:USER:taskMaster.c:6720:Socket #1: I1=11.1A I2=11.2A I3=11.2A P=7.9kW Idc=0.7mA
2025-11-05T02:42:00.921Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-05T02:42:00.937Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-05T02:42:12.921Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T02:42:12.933Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.5)
2025-11-05T02:42:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:42:19.066Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=236.7V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:42:19.078Z:USER:taskMaster.c:6720:Socket #1: I1=10.7A I2=10.8A I3=10.7A P=7.6kW Idc=0.7mA
2025-11-05T02:42:24.921Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:42:36.917Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T02:42:48.917Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-05T02:42:49.062Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=236.6V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:42:49.074Z:USER:taskMaster.c:6720:Socket #1: I1=11.1A I2=11.3A I3=11.1A P=7.9kW Idc=0.7mA
2025-11-05T02:43:00.917Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T02:43:00.929Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-05T02:43:12.914Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:43:12.929Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-05T02:43:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:43:19.058Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=236.7V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:43:19.070Z:USER:taskMaster.c:6720:Socket #1: I1=11.1A I2=11.1A I3=11.1A P=7.8kW Idc=0.7mA
2025-11-05T02:43:24.914Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-05T02:43:24.925Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-05T02:43:36.914Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T02:43:36.925Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.5)
2025-11-05T02:43:48.914Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:43:49.054Z:USER:taskMaster.c:6684:Socket #1: L1N=236.4V L2N=236.9V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:43:49.070Z:USER:taskMaster.c:6720:Socket #1: I1=10.8A I2=10.8A I3=10.7A P=7.6kW Idc=0.7mA
2025-11-05T02:44:00.910Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T02:44:12.910Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-05T02:44:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:44:19.054Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=236.6V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:44:19.066Z:USER:taskMaster.c:6720:Socket #1: I1=11.4A I2=11.4A I3=11.3A P=8.0kW Idc=0.7mA
2025-11-05T02:44:19.074Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-05T02:44:24.910Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T02:44:24.921Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-05T02:44:36.906Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:44:36.917Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.9)
2025-11-05T02:44:41.152Z:INFO:active_lb.c:308:SMt:(11.0 12.0 16.0)A Free:(5.0 4.0 0.0)A ALB:(15.7 14.8 11.4)A
2025-11-05T02:44:48.906Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T02:44:48.917Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T02:45:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T02:45:00.906Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:45:12.902Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-05T02:45:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:45:24.902Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T02:45:24.914Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-05T02:45:36.902Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T02:45:36.914Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-05T02:45:48.898Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-05T02:45:48.914Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.6)
2025-11-05T02:46:00.898Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:46:12.898Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T02:46:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:46:24.894Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-05T02:46:36.894Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T02:46:36.906Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-05T02:46:48.894Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:46:48.906Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-05T02:47:00.890Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->10.1 due to current limit: Active-LoadBalancing
2025-11-05T02:47:00.906Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->16.8)
2025-11-05T02:47:01.542Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.8% (10.1 A)
2025-11-05T02:47:12.890Z:INFO:taskMain.c:5996:Socket #1: Active current 10.1->8.4 due to current limit: Active-LoadBalancing
2025-11-05T02:47:12.902Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (16.8->13.9)
2025-11-05T02:47:13.660Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.9% (8.3 A)
2025-11-05T02:47:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:47:24.890Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->10.3 due to current limit: Active-LoadBalancing
2025-11-05T02:47:25.781Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.1% (10.3 A)
2025-11-05T02:47:36.886Z:INFO:taskMain.c:5996:Socket #1: Active current 10.3->11.7 due to current limit: Active-LoadBalancing
2025-11-05T02:47:36.902Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.5% (11.7 A)
2025-11-05T02:47:48.886Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->12.4 due to current limit: Active-LoadBalancing
2025-11-05T02:47:49.007Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-11-05T02:48:00.886Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-11-05T02:48:00.898Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.6->20.3)
2025-11-05T02:48:12.882Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.0 due to current limit: Active-LoadBalancing
2025-11-05T02:48:12.898Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.3->20.0)
2025-11-05T02:48:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:48:24.882Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->11.9 due to current limit: Active-LoadBalancing
2025-11-05T02:48:24.894Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.0->19.7)
2025-11-05T02:48:36.882Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.7 due to current limit: Active-LoadBalancing
2025-11-05T02:48:36.894Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.7->19.4)
2025-11-05T02:48:48.878Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T02:48:48.894Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-05T02:49:00.878Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T02:49:00.890Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.9)
2025-11-05T02:49:12.878Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-05T02:49:12.890Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T02:49:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:49:24.875Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:49:36.875Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-05T02:49:48.875Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T02:49:48.886Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-05T02:50:00.871Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:50:00.886Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.9)
2025-11-05T02:50:12.871Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T02:50:12.882Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T02:50:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:50:24.871Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:50:36.871Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-05T02:50:48.867Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T02:50:48.878Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.2)
2025-11-05T02:51:00.867Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:51:00.878Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-05T02:51:12.867Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T02:51:12.878Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T02:51:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:51:24.863Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:51:36.863Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-05T02:51:48.863Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.9 due to current limit: Active-LoadBalancing
2025-11-05T02:52:00.859Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.7 due to current limit: Active-LoadBalancing
2025-11-05T02:52:00.871Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.8->19.5)
2025-11-05T02:52:12.859Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-05T02:52:12.871Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-05T02:52:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:52:17.851Z:USER:taskMaster.c:6582:Temperature: 28.5 C
2025-11-05T02:52:24.859Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:52:24.871Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-05T02:52:36.855Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T02:52:36.871Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T02:52:48.855Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:53:00.855Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-05T02:53:12.851Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->10.3 due to current limit: Active-LoadBalancing
2025-11-05T02:53:12.867Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->17.1)
2025-11-05T02:53:13.183Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.1% (10.3 A)
2025-11-05T02:53:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:53:24.851Z:INFO:taskMain.c:5996:Socket #1: Active current 10.3->10.1 due to current limit: Active-LoadBalancing
2025-11-05T02:53:24.863Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (17.1->16.9)
2025-11-05T02:53:36.851Z:INFO:taskMain.c:5996:Socket #1: Active current 10.1->10.8 due to current limit: Active-LoadBalancing
2025-11-05T02:53:37.421Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.9% (10.7 A)
2025-11-05T02:53:48.847Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:53:49.539Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.9% (11.3 A)
2025-11-05T02:54:00.847Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T02:54:12.847Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-05T02:54:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:54:24.843Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T02:54:24.859Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-05T02:54:36.843Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:54:36.855Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.9)
2025-11-05T02:54:41.085Z:INFO:active_lb.c:308:SMt:(13.0 12.0 16.0)A Free:(3.0 4.0 0.0)A ALB:(14.5 14.8 11.4)A
2025-11-05T02:54:48.843Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T02:54:48.855Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T02:55:00.839Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:55:12.839Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-05T02:55:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:55:24.839Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T02:55:24.851Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-05T02:55:36.835Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T02:55:36.851Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.9)
2025-11-05T02:55:48.835Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-05T02:55:48.847Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T02:56:00.835Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:56:12.832Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-05T02:56:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:56:24.832Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T02:56:24.843Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-05T02:56:36.832Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T02:56:36.843Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-05T02:56:48.828Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T02:56:48.843Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-05T02:57:00.828Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:57:12.828Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T02:57:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:57:24.824Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-05T02:57:36.824Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T02:57:36.835Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-05T02:57:48.824Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:57:48.835Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.9)
2025-11-05T02:58:00.824Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T02:58:00.835Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T02:58:12.820Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:58:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:58:15.714Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000016, address 0x00016000 (1)
2025-11-05T02:58:15.726Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-05T02:58:24.820Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-05T02:58:36.820Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.9 due to current limit: Active-LoadBalancing
2025-11-05T02:58:48.816Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.7 due to current limit: Active-LoadBalancing
2025-11-05T02:58:48.828Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.7->19.5)
2025-11-05T02:59:00.816Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-05T02:59:00.828Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-05T02:59:12.816Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T02:59:12.828Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-05T02:59:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T02:59:18.957Z:USER:taskMaster.c:6684:Socket #1: L1N=236.2V L2N=236.7V L3N=235.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T02:59:18.968Z:USER:taskMaster.c:6720:Socket #1: I1=11.0A I2=11.0A I3=11.0A P=7.8kW Idc=0.7mA
2025-11-05T02:59:24.812Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T02:59:24.828Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.7)
2025-11-05T02:59:36.812Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.1 due to current limit: Active-LoadBalancing
2025-11-05T02:59:36.824Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-05T02:59:48.812Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:00:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T03:00:00.808Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:00:12.808Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:00:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:00:24.808Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:00:24.820Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-05T03:00:30.203Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-05T03:00:30.214Z:INFO:db_chargingprofi:26: socket 0
2025-11-05T03:00:30.222Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-05T03:00:30.230Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-05T03:00:30.238Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-05T03:00:30.246Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-05T03:00:30.257Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-05T03:00:30.265Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-05T03:00:30.277Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-05T03:00:30.285Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-05T03:00:30.292Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-05T03:00:30.300Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-05T03:00:30.308Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-05T03:00:30.316Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-05T03:00:30.324Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-05T03:00:30.332Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-05T03:00:30.339Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-05T03:00:30.351Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-05T03:00:30.359Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-05T03:00:30.367Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-05T03:00:30.375Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-05T03:00:30.382Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-05T03:00:30.390Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-05T03:00:36.804Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:00:36.820Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.7)
2025-11-05T03:00:48.804Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:01:00.804Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:01:12.800Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.9 due to current limit: Active-LoadBalancing
2025-11-05T03:01:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:01:24.800Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:01:24.812Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.7->19.5)
2025-11-05T03:01:36.800Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:01:36.812Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-05T03:01:48.796Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:01:48.812Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-05T03:02:00.796Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:02:00.808Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T03:02:12.796Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-05T03:02:12.808Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.4)
2025-11-05T03:02:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:02:24.792Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:02:36.792Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:02:48.792Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:03:00.789Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:03:00.804Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-05T03:03:12.789Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:03:12.800Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.7)
2025-11-05T03:03:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:03:24.789Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:03:24.800Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-05T03:03:36.785Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:03:48.785Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:04:00.785Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:04:12.781Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->12.0 due to current limit: Active-LoadBalancing
2025-11-05T03:04:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:04:24.781Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->11.8 due to current limit: Active-LoadBalancing
2025-11-05T03:04:24.792Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.9->19.6)
2025-11-05T03:04:36.781Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:04:36.792Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-05T03:04:41.023Z:INFO:active_lb.c:308:SMt:(12.0 13.0 16.0)A Free:(4.0 3.0 0.0)A ALB:(15.6 14.5 11.6)A
2025-11-05T03:04:48.777Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:04:48.792Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-05T03:05:00.777Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:05:00.789Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-05T03:05:12.777Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:05:12.789Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-05T03:05:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:05:24.777Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:05:36.773Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:05:48.773Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:06:00.773Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:06:00.785Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-05T03:06:12.769Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:06:12.781Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->19.0)
2025-11-05T03:06:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:06:24.769Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:06:24.781Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-05T03:06:36.769Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:06:36.781Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-05T03:06:48.765Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:07:00.765Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:07:12.765Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:07:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:07:18.207Z:USER:taskMaster.c:6582:Temperature: 29.6 C
2025-11-05T03:07:24.761Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:07:24.777Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-05T03:07:36.761Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:07:36.773Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->19.0)
2025-11-05T03:07:48.761Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:07:48.773Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-05T03:08:00.757Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:08:00.773Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-05T03:08:12.757Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:08:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:08:24.757Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:08:36.753Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:08:48.753Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:08:48.765Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-05T03:09:00.753Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:09:00.765Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->19.0)
2025-11-05T03:09:12.750Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:09:12.765Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-05T03:09:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:09:24.800Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:09:24.812Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-05T03:09:36.796Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:09:48.796Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:10:00.796Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.8 due to current limit: Active-LoadBalancing
2025-11-05T03:10:12.796Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:10:12.808Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-05T03:10:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:10:24.792Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:10:24.804Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-05T03:10:36.792Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:10:36.804Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.8)
2025-11-05T03:10:48.792Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:10:48.804Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-05T03:11:00.789Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:11:12.789Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:11:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:11:24.789Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-05T03:11:36.785Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:11:36.796Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-05T03:11:48.785Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:11:48.796Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.1)
2025-11-05T03:12:00.785Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:12:00.796Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-05T03:12:12.781Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:12:12.792Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-05T03:12:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:12:24.781Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:12:36.781Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:12:48.777Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-05T03:13:00.777Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:13:00.789Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-05T03:13:12.777Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:13:12.789Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.1)
2025-11-05T03:13:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:13:24.773Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:13:24.789Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-05T03:13:36.773Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:13:36.785Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-05T03:13:48.773Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:14:00.769Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:14:12.769Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-05T03:14:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:14:18.863Z:USER:taskMaster.c:6684:Socket #1: L1N=235.3V L2N=236.0V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T03:14:18.878Z:USER:taskMaster.c:6720:Socket #1: I1=11.4A I2=11.4A I3=11.4A P=8.0kW Idc=0.7mA
2025-11-05T03:14:24.769Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:14:24.781Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-05T03:14:36.765Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:14:36.781Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.1)
2025-11-05T03:14:40.960Z:INFO:active_lb.c:308:SMt:(12.0 12.0 16.0)A Free:(4.0 4.0 0.0)A ALB:(15.5 15.3 11.5)A
2025-11-05T03:14:48.765Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:14:48.777Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-05T03:15:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T03:15:00.765Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:15:00.777Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-05T03:15:12.761Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:15:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:15:24.761Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:15:36.761Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-05T03:15:48.757Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:15:48.773Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.7->19.4)
2025-11-05T03:16:00.757Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:16:00.769Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-05T03:16:12.757Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:16:12.769Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-05T03:16:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:16:24.753Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:16:24.769Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-05T03:16:36.753Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:16:48.753Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:17:00.750Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-05T03:17:12.750Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:17:12.761Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.4)
2025-11-05T03:17:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:17:24.750Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:17:24.761Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-05T03:17:36.746Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:17:36.761Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-05T03:17:48.746Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:17:48.757Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-05T03:18:00.746Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:18:12.746Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:18:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:18:24.742Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-05T03:18:36.742Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:18:36.753Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-05T03:18:48.742Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:18:48.753Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.9)
2025-11-05T03:19:00.738Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:19:00.750Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T03:19:12.738Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-05T03:19:12.750Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-05T03:19:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:19:24.738Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->9.6 due to current limit: Active-LoadBalancing
2025-11-05T03:19:24.750Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.3->16.0)
2025-11-05T03:19:25.617Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.0% (9.6 A)
2025-11-05T03:19:36.734Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->9.8 due to current limit: Active-LoadBalancing
2025-11-05T03:19:48.734Z:INFO:taskMain.c:5996:Socket #1: Active current 9.8->10.4 due to current limit: Active-LoadBalancing
2025-11-05T03:19:48.843Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.3% (10.4 A)
2025-11-05T03:20:00.734Z:INFO:taskMain.c:5996:Socket #1: Active current 10.4->11.0 due to current limit: Active-LoadBalancing
2025-11-05T03:20:00.960Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.3% (11.0 A)
2025-11-05T03:20:12.730Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:20:13.082Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.3% (11.6 A)
2025-11-05T03:20:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:20:24.730Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-05T03:20:36.730Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:20:36.742Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.4)
2025-11-05T03:20:48.726Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:20:48.742Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-05T03:21:00.726Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:21:00.738Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-05T03:21:12.726Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:21:12.738Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-05T03:21:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:21:24.722Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.0 due to current limit: Active-LoadBalancing
2025-11-05T03:21:24.738Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->18.2)
2025-11-05T03:21:36.722Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:21:48.722Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:22:00.718Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:22:12.718Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:22:12.730Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-05T03:22:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:22:18.613Z:USER:taskMaster.c:6582:Temperature: 30.0 C
2025-11-05T03:22:24.718Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:22:24.730Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-05T03:22:36.714Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:22:36.730Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.6)
2025-11-05T03:22:48.714Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-05T03:22:48.726Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-05T03:23:00.714Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:23:12.710Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:23:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:23:24.710Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:23:36.710Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:23:36.722Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.2)
2025-11-05T03:23:48.707Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:23:48.722Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-05T03:24:00.707Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:24:00.718Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T03:24:12.707Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-05T03:24:12.718Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-05T03:24:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:24:24.703Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:24:36.703Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:24:40.898Z:INFO:active_lb.c:308:SMt:(12.0 11.0 15.0)A Free:(4.0 5.0 1.0)A ALB:(14.5 15.7 11.4)A
2025-11-05T03:24:48.703Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:24:48.714Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.8)
2025-11-05T03:25:00.699Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:25:00.714Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.4)
2025-11-05T03:25:12.699Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->10.9 due to current limit: Active-LoadBalancing
2025-11-05T03:25:12.710Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.4->18.1)
2025-11-05T03:25:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:25:24.699Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:25:36.695Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:25:48.695Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:26:00.695Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:26:12.695Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:26:12.707Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-05T03:26:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:26:24.691Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:26:24.703Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-05T03:26:36.691Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:26:36.703Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T03:26:48.691Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-05T03:26:48.703Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-05T03:27:00.687Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:27:12.687Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:27:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:27:24.687Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:27:24.699Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.8)
2025-11-05T03:27:36.683Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:27:36.695Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.4)
2025-11-05T03:27:48.683Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:28:00.683Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:28:12.679Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:28:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:28:24.679Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:28:24.691Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-05T03:28:36.679Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:28:36.691Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-05T03:28:48.675Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:28:48.691Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T03:29:00.675Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-05T03:29:00.687Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-05T03:29:12.675Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->10.9 due to current limit: Active-LoadBalancing
2025-11-05T03:29:12.687Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.3->18.0)
2025-11-05T03:29:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:29:18.769Z:USER:taskMaster.c:6684:Socket #1: L1N=235.1V L2N=235.7V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T03:29:18.781Z:USER:taskMaster.c:6720:Socket #1: I1=10.5A I2=10.5A I3=10.4A P=7.4kW Idc=0.7mA
2025-11-05T03:29:24.671Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:29:36.671Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:29:48.671Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:30:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T03:30:00.667Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:30:12.667Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:30:12.679Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.2)
2025-11-05T03:30:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:30:24.667Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:30:24.679Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-05T03:30:36.664Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:30:36.679Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T03:30:48.664Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-05T03:30:48.675Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-05T03:31:00.664Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:31:12.660Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:31:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:31:24.660Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:31:36.660Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:31:36.671Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-05T03:31:48.656Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:31:48.671Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.7)
2025-11-05T03:32:00.656Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:32:00.667Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-05T03:32:12.656Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->10.9 due to current limit: Active-LoadBalancing
2025-11-05T03:32:12.667Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.4->18.1)
2025-11-05T03:32:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:32:24.652Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:32:36.652Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:32:48.652Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:33:00.648Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:33:00.664Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-05T03:33:12.648Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:33:12.660Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.8)
2025-11-05T03:33:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:33:24.648Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:33:24.660Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.4)
2025-11-05T03:33:36.644Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:33:48.644Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:34:00.644Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:34:12.644Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:34:12.656Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.2)
2025-11-05T03:34:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:34:24.640Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:34:24.652Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-05T03:34:32.582Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-05T03:34:32.593Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-05T03:34:36.640Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:34:36.652Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T03:34:40.832Z:INFO:active_lb.c:308:SMt:(11.0 12.0 16.0)A Free:(5.0 4.0 0.0)A ALB:(16.1 15.4 11.2)A
2025-11-05T03:34:48.640Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-05T03:34:48.652Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.4)
2025-11-05T03:35:00.636Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:35:12.636Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:35:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:35:24.636Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:35:36.632Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:35:36.644Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-05T03:35:48.632Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:35:48.644Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-05T03:36:00.632Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:36:00.644Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-05T03:36:12.628Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.0 due to current limit: Active-LoadBalancing
2025-11-05T03:36:12.644Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->18.2)
2025-11-05T03:36:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:36:24.628Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:36:36.628Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:36:48.625Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:37:00.625Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:37:00.636Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-05T03:37:12.625Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:37:12.636Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-05T03:37:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:37:18.968Z:USER:taskMaster.c:6582:Temperature: 30.2 C
2025-11-05T03:37:24.621Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:37:24.636Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-05T03:37:36.621Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:37:48.621Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:38:00.617Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.8 due to current limit: Active-LoadBalancing
2025-11-05T03:38:12.617Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:38:12.628Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-05T03:38:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:38:24.617Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:38:24.628Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-05T03:38:36.613Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:38:36.628Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-05T03:38:48.613Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:38:48.625Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-05T03:39:00.613Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:39:12.609Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:39:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:39:24.609Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.8 due to current limit: Active-LoadBalancing
2025-11-05T03:39:36.609Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:39:36.621Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-05T03:39:48.605Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:39:48.621Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-05T03:40:00.605Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:40:00.617Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-05T03:40:12.605Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:40:12.617Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.5)
2025-11-05T03:40:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:40:24.601Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->10.9 due to current limit: Active-LoadBalancing
2025-11-05T03:40:24.617Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->18.2)
2025-11-05T03:40:36.601Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:40:48.601Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:41:00.597Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:41:12.597Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-05T03:41:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:41:24.597Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:41:24.609Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.7->19.4)
2025-11-05T03:41:36.593Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:41:36.609Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-05T03:41:48.593Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:41:48.605Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-05T03:42:00.593Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:42:00.605Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-05T03:42:12.593Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->10.9 due to current limit: Active-LoadBalancing
2025-11-05T03:42:12.605Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->18.2)
2025-11-05T03:42:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:42:24.589Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:42:36.589Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:42:48.589Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:43:00.585Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:43:00.597Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.1)
2025-11-05T03:43:12.585Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:43:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:43:24.585Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:43:24.597Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-05T03:43:36.582Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:43:36.593Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-05T03:43:48.582Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:43:48.593Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-05T03:44:00.582Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:44:12.578Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:44:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:44:18.671Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=234.8V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T03:44:18.683Z:USER:taskMaster.c:6720:Socket #1: I1=11.2A I2=11.2A I3=11.2A P=7.9kW Idc=0.7mA
2025-11-05T03:44:24.578Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.8 due to current limit: Active-LoadBalancing
2025-11-05T03:44:36.578Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:44:36.589Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-05T03:44:40.769Z:INFO:active_lb.c:308:SMt:(11.0 12.0 16.0)A Free:(5.0 4.0 0.0)A ALB:(16.2 15.8 11.6)A
2025-11-05T03:44:48.574Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:44:48.589Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-05T03:45:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T03:45:00.574Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:45:00.585Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.8)
2025-11-05T03:45:12.574Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:45:12.585Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-05T03:45:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:45:24.570Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->10.9 due to current limit: Active-LoadBalancing
2025-11-05T03:45:24.585Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->18.2)
2025-11-05T03:45:36.570Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:45:48.570Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:46:00.566Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:46:12.566Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-05T03:46:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:46:24.566Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->12.0 due to current limit: Active-LoadBalancing
2025-11-05T03:46:36.562Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->11.8 due to current limit: Active-LoadBalancing
2025-11-05T03:46:36.578Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.0->19.7)
2025-11-05T03:46:48.562Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:46:48.574Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.7->19.4)
2025-11-05T03:47:00.562Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:47:00.574Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-05T03:47:12.558Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:47:12.574Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-05T03:47:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:47:24.558Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:47:24.570Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-05T03:47:36.558Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->10.9 due to current limit: Active-LoadBalancing
2025-11-05T03:47:36.570Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->18.2)
2025-11-05T03:47:48.554Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:48:00.554Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:48:12.554Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:48:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:48:24.550Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-05T03:48:36.550Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:48:36.562Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-05T03:48:48.550Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:48:48.562Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.9)
2025-11-05T03:49:00.546Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:49:00.562Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T03:49:12.546Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-05T03:49:12.558Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.2)
2025-11-05T03:49:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:49:24.546Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->10.8 due to current limit: Active-LoadBalancing
2025-11-05T03:49:24.558Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.2->17.9)
2025-11-05T03:49:36.542Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->11.0 due to current limit: Active-LoadBalancing
2025-11-05T03:49:48.542Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:50:00.542Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:50:12.542Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:50:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:50:24.539Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-05T03:50:36.539Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:50:36.550Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-05T03:50:48.539Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:50:48.550Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-05T03:51:00.535Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:51:00.546Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.8)
2025-11-05T03:51:12.535Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:51:12.546Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-05T03:51:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:51:24.535Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->10.9 due to current limit: Active-LoadBalancing
2025-11-05T03:51:24.546Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->18.2)
2025-11-05T03:51:36.531Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->10.8 due to current limit: Active-LoadBalancing
2025-11-05T03:51:36.542Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.2->17.9)
2025-11-05T03:51:48.531Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->11.0 due to current limit: Active-LoadBalancing
2025-11-05T03:52:00.531Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:52:12.527Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:52:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:52:19.371Z:USER:taskMaster.c:6582:Temperature: 30.2 C
2025-11-05T03:52:24.527Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:52:36.527Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-05T03:52:48.523Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:52:48.539Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-05T03:53:00.523Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:53:00.535Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-05T03:53:12.523Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:53:12.535Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-05T03:53:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:53:24.519Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:53:24.535Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.5)
2025-11-05T03:53:36.519Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->10.9 due to current limit: Active-LoadBalancing
2025-11-05T03:53:36.531Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->18.2)
2025-11-05T03:53:48.519Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:54:00.515Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:54:12.515Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:54:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:54:24.515Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-05T03:54:36.511Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:54:36.527Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-05T03:54:40.707Z:INFO:active_lb.c:308:SMt:(12.0 12.0 16.0)A Free:(4.0 4.0 0.0)A ALB:(15.1 15.5 11.6)A
2025-11-05T03:54:48.511Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:54:48.523Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.9)
2025-11-05T03:55:00.511Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:55:00.523Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T03:55:12.507Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-05T03:55:12.523Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-05T03:55:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:55:24.507Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->10.8 due to current limit: Active-LoadBalancing
2025-11-05T03:55:24.519Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.3->17.9)
2025-11-05T03:55:36.507Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->11.0 due to current limit: Active-LoadBalancing
2025-11-05T03:55:48.503Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:56:00.503Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:56:12.503Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:56:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:56:24.500Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.9 due to current limit: Active-LoadBalancing
2025-11-05T03:56:36.500Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:56:36.511Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.8->19.4)
2025-11-05T03:56:48.500Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:56:48.511Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-05T03:57:00.496Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T03:57:00.511Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-05T03:57:12.496Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T03:57:12.507Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-05T03:57:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:57:24.496Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.0 due to current limit: Active-LoadBalancing
2025-11-05T03:57:24.507Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->18.2)
2025-11-05T03:57:36.492Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->10.8 due to current limit: Active-LoadBalancing
2025-11-05T03:57:36.507Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.2->17.9)
2025-11-05T03:57:48.492Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->11.0 due to current limit: Active-LoadBalancing
2025-11-05T03:58:00.492Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:58:12.488Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.5 due to current limit: Active-LoadBalancing
2025-11-05T03:58:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:58:24.488Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-05T03:58:36.488Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-05T03:58:36.500Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-05T03:58:48.488Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T03:58:48.500Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-05T03:59:00.484Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T03:59:00.496Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T03:59:12.484Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-05T03:59:12.496Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-05T03:59:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T03:59:15.277Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000017, address 0x00017000 (1)
2025-11-05T03:59:15.289Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-05T03:59:18.578Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=235.4V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T03:59:18.589Z:USER:taskMaster.c:6720:Socket #1: I1=10.6A I2=10.6A I3=10.5A P=7.4kW Idc=0.7mA
2025-11-05T03:59:24.484Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->10.8 due to current limit: Active-LoadBalancing
2025-11-05T03:59:24.496Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.3->18.0)
2025-11-05T03:59:36.480Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->11.0 due to current limit: Active-LoadBalancing
2025-11-05T03:59:48.480Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.3 due to current limit: Active-LoadBalancing
2025-11-05T04:00:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T04:00:00.480Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T04:00:07.421Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-05T04:00:07.433Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-05T04:00:07.441Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-05T04:00:07.449Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-05T04:00:07.539Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-05T04:00:08.437Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-05T04:00:12.476Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->7.3 due to current limit: Active-LoadBalancing
2025-11-05T04:00:12.488Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.1% (7.3 A)
2025-11-05T04:00:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:00:24.476Z:INFO:taskMain.c:5996:Socket #1: Active current 7.3->4.4 due to current limit: Active-LoadBalancing
2025-11-05T04:00:24.488Z:WARNING:taskMain.c:4698:Socket #1: maximum current(4.37) < minimum current(6.00)
2025-11-05T04:00:24.519Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-05T04:00:24.531Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-05T04:00:24.539Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-05T04:00:24.597Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-05T04:00:25.515Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-11-05T04:00:25.515Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-05T04:00:36.476Z:INFO:taskMain.c:5996:Socket #1: Active current 4.4->7.0 due to current limit: Active-LoadBalancing
2025-11-05T04:00:36.519Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-05T04:00:36.527Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-05T04:00:36.539Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-05T04:00:36.625Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-05T04:00:37.523Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-05T04:00:37.773Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-05T04:00:37.781Z:INFO:db_chargingprofi:26: socket 0
2025-11-05T04:00:37.789Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-05T04:00:37.796Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-05T04:00:37.804Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-05T04:00:37.816Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-05T04:00:37.824Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-05T04:00:37.832Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-05T04:00:37.843Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-05T04:00:37.851Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-05T04:00:37.859Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-05T04:00:37.867Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-05T04:00:37.875Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-05T04:00:37.882Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-05T04:00:37.890Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-05T04:00:37.898Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-05T04:00:37.910Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-05T04:00:37.917Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-05T04:00:37.925Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-05T04:00:37.933Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-05T04:00:37.941Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-05T04:00:37.949Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-05T04:00:37.957Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-05T04:00:48.472Z:INFO:taskMain.c:5996:Socket #1: Active current 7.0->8.6 due to current limit: Active-LoadBalancing
2025-11-05T04:00:48.632Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.3% (8.6 A)
2025-11-05T04:01:00.472Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->9.6 due to current limit: Active-LoadBalancing
2025-11-05T04:01:00.753Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.9% (9.5 A)
2025-11-05T04:01:06.566Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-05T04:01:06.574Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-05T04:01:06.812Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-05T04:01:06.820Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-05T04:01:07.562Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-05T04:01:10.566Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-05T04:01:10.589Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-05T04:01:10.597Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-05T04:01:11.066Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-05T04:01:11.074Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-05T04:01:11.601Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-05T04:01:12.089Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-05T04:01:12.472Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->10.1 due to current limit: Active-LoadBalancing
2025-11-05T04:01:13.101Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.9% (10.1 A)
2025-11-05T04:01:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:01:15.316Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-05T04:01:15.324Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-05T04:01:15.332Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=235.9V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T04:01:15.343Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T04:01:15.355Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-05T04:01:15.363Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-05T04:01:15.375Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-05T04:01:16.128Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-05T04:01:16.332Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-05T04:01:24.468Z:INFO:taskMain.c:5996:Socket #1: Active current 10.1->14.4 due to current limit: Active-LoadBalancing
2025-11-05T04:01:25.417Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.9% (14.3 A)
2025-11-05T04:01:36.468Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->15.0 due to current limit: Active-LoadBalancing
2025-11-05T04:01:36.527Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.0% (15.0 A)
2025-11-05T04:01:45.363Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=234.2V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T04:01:45.375Z:USER:taskMaster.c:6720:Socket #1: I1=14.7A I2=14.7A I3=14.7A P=10.3kW Idc=0.7mA
2025-11-05T04:01:48.468Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->13.7 due to current limit: Active-LoadBalancing
2025-11-05T04:01:48.480Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->22.8)
2025-11-05T04:01:48.648Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.8% (13.7 A)
2025-11-05T04:02:00.464Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->12.7 due to current limit: Active-LoadBalancing
2025-11-05T04:02:00.480Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.8->21.2)
2025-11-05T04:02:00.765Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.2% (12.7 A)
2025-11-05T04:02:12.464Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->11.8 due to current limit: Active-LoadBalancing
2025-11-05T04:02:12.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.2->19.6)
2025-11-05T04:02:12.886Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.6% (11.8 A)
2025-11-05T04:02:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:02:15.316Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-05T04:02:15.359Z:USER:taskMaster.c:6684:Socket #1: L1N=236.4V L2N=236.9V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T04:02:15.371Z:USER:taskMaster.c:6720:Socket #1: I1=11.4A I2=11.4A I3=11.4A P=8.1kW Idc=0.7mA
2025-11-05T04:02:24.464Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.2 due to current limit: Active-LoadBalancing
2025-11-05T04:02:24.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->18.7)
2025-11-05T04:02:25.003Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.7% (11.2 A)
2025-11-05T04:02:36.460Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.1 due to current limit: Active-LoadBalancing
2025-11-05T04:02:36.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-05T04:02:45.355Z:USER:taskMaster.c:6684:Socket #1: L1N=237.0V L2N=237.2V L3N=236.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T04:02:45.367Z:USER:taskMaster.c:6720:Socket #1: I1=10.7A I2=10.7A I3=10.7A P=7.6kW Idc=0.7mA
2025-11-05T04:02:48.460Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->10.9 due to current limit: Active-LoadBalancing
2025-11-05T04:02:48.472Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.4->18.1)
2025-11-05T04:03:00.460Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.1 due to current limit: Active-LoadBalancing
2025-11-05T04:03:12.457Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-05T04:03:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:03:15.351Z:USER:taskMaster.c:6684:Socket #1: L1N=236.9V L2N=237.2V L3N=236.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T04:03:15.363Z:USER:taskMaster.c:6720:Socket #1: I1=11.0A I2=11.0A I3=11.0A P=7.8kW Idc=0.7mA
2025-11-05T04:03:24.457Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T04:03:36.457Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-05T04:03:36.468Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.1)
2025-11-05T04:03:45.347Z:USER:taskMaster.c:6684:Socket #1: L1N=236.7V L2N=237.3V L3N=236.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T04:03:45.367Z:USER:taskMaster.c:6720:Socket #1: I1=11.0A I2=11.1A I3=11.0A P=7.8kW Idc=0.7mA
2025-11-05T04:03:48.453Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T04:03:48.468Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-05T04:04:00.453Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T04:04:00.464Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-05T04:04:12.453Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->10.9 due to current limit: Active-LoadBalancing
2025-11-05T04:04:12.464Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->18.2)
2025-11-05T04:04:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:04:15.347Z:USER:taskMaster.c:6684:Socket #1: L1N=236.5V L2N=236.8V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T04:04:15.359Z:USER:taskMaster.c:6720:Socket #1: I1=10.5A I2=10.6A I3=10.5A P=7.5kW Idc=0.7mA
2025-11-05T04:04:24.449Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.2 due to current limit: Active-LoadBalancing
2025-11-05T04:04:36.449Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T04:04:40.644Z:INFO:active_lb.c:308:SMt:(11.0 11.0 15.0)A Free:(5.0 5.0 1.0)A ALB:(15.7 15.2 11.4)A
2025-11-05T04:04:45.343Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=236.7V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T04:04:45.355Z:USER:taskMaster.c:6720:Socket #1: I1=11.0A I2=11.0A I3=10.9A P=7.7kW Idc=0.7mA
2025-11-05T04:04:48.449Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T04:05:00.445Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T04:05:00.460Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-05T04:05:12.445Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-05T04:05:12.457Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-05T04:05:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:05:15.339Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=236.6V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T04:05:15.351Z:USER:taskMaster.c:6720:Socket #1: I1=10.9A I2=10.9A I3=10.9A P=7.7kW Idc=0.7mA
2025-11-05T04:05:24.445Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T04:05:24.457Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.5)
2025-11-05T04:05:36.441Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.0 due to current limit: Active-LoadBalancing
2025-11-05T04:05:36.457Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->18.2)
2025-11-05T04:05:45.335Z:USER:taskMaster.c:6684:Socket #1: L1N=236.2V L2N=236.7V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T04:05:45.347Z:USER:taskMaster.c:6720:Socket #1: I1=10.5A I2=10.6A I3=10.5A P=7.5kW Idc=0.7mA
2025-11-05T04:05:48.441Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-05T04:06:00.441Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T04:06:12.437Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T04:06:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:06:15.332Z:USER:taskMaster.c:6684:Socket #1: L1N=235.9V L2N=236.3V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T04:06:15.343Z:USER:taskMaster.c:6720:Socket #1: I1=11.2A I2=11.2A I3=11.1A P=7.9kW Idc=0.7mA
2025-11-05T04:06:15.355Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-05T04:06:24.437Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T04:06:24.449Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.9)
2025-11-05T04:06:36.437Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T04:06:36.449Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T04:06:48.437Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-05T04:06:48.449Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-05T04:07:00.433Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-05T04:07:12.433Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.5 due to current limit: Active-LoadBalancing
2025-11-05T04:07:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:07:19.726Z:USER:taskMaster.c:6582:Temperature: 30.2 C
2025-11-05T04:07:24.433Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T04:07:24.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-05T04:07:36.480Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-05T04:07:36.492Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.6)
2025-11-05T04:07:48.480Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-05T04:07:48.492Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-05T04:08:00.476Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-05T04:08:12.476Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T04:08:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:08:24.476Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-05T04:08:36.472Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-05T04:08:36.488Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-05T04:08:48.472Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T04:08:48.484Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-05T04:09:00.472Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T04:09:00.484Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T04:09:12.468Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-05T04:09:12.484Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-05T04:09:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:09:24.468Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.3 due to current limit: Active-LoadBalancing
2025-11-05T04:09:36.468Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T04:09:48.464Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-05T04:10:00.464Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T04:10:00.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.2)
2025-11-05T04:10:12.464Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-05T04:10:12.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-05T04:10:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:10:24.460Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T04:10:24.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T04:10:36.460Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-05T04:10:36.472Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.4)
2025-11-05T04:10:48.460Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.3 due to current limit: Active-LoadBalancing
2025-11-05T04:11:00.457Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T04:11:12.457Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-05T04:11:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:11:24.457Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T04:11:24.468Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-05T04:11:36.457Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-05T04:11:36.468Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-05T04:11:48.453Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T04:11:48.464Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T04:12:00.453Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T04:12:12.453Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-05T04:12:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:12:24.449Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T04:12:24.460Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.2)
2025-11-05T04:12:36.449Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-05T04:12:36.460Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-05T04:12:48.449Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T04:12:48.460Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T04:13:00.445Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-05T04:13:00.457Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-05T04:13:12.445Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-05T04:13:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:13:24.445Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.5 due to current limit: Active-LoadBalancing
2025-11-05T04:13:36.441Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-05T04:13:48.441Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-05T04:13:48.453Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-05T04:14:00.441Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-05T04:14:00.453Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-05T04:14:12.437Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T04:14:12.453Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-05T04:14:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:14:24.437Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-05T04:14:24.449Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-05T04:14:36.437Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-05T04:14:40.578Z:INFO:active_lb.c:308:SMt:(11.0 11.0 15.0)A Free:(5.0 5.0 1.0)A ALB:(15.8 15.6 11.2)A
2025-11-05T04:14:48.433Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.5 due to current limit: Active-LoadBalancing
2025-11-05T04:15:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T04:15:00.433Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-05T04:15:00.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.8)
2025-11-05T04:15:12.433Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T04:15:12.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-05T04:15:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:15:24.429Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.0 due to current limit: Active-LoadBalancing
2025-11-05T04:15:24.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->18.2)
2025-11-05T04:15:36.429Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-05T04:15:48.429Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-05T04:16:00.425Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-05T04:16:00.441Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.8)
2025-11-05T04:16:12.425Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-05T04:16:12.437Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.4)
2025-11-05T04:16:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:16:24.425Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->10.9 due to current limit: Active-LoadBalancing
2025-11-05T04:16:24.437Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.4->18.1)
2025-11-05T04:16:36.421Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.1 due to current limit: Active-LoadBalancing
2025-11-05T04:16:48.421Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-05T04:17:00.421Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-05T04:17:12.417Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-05T04:17:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:17:23.562Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-05T04:17:23.570Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-05T04:17:23.582Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-05T04:17:23.589Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-05T04:17:23.796Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-05T04:17:24.417Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-05T04:17:24.597Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-05T04:17:36.417Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->6.9 due to current limit: Active-LoadBalancing
2025-11-05T04:17:36.718Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.5% (6.9 A)
2025-11-05T04:17:48.414Z:INFO:taskMain.c:5996:Socket #1: Active current 6.9->8.6 due to current limit: Active-LoadBalancing
2025-11-05T04:17:48.835Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.2% (8.5 A)
2025-11-05T04:18:00.414Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->9.5 due to current limit: Active-LoadBalancing
2025-11-05T04:18:00.953Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.8% (9.5 A)
2025-11-05T04:18:12.414Z:INFO:taskMain.c:5996:Socket #1: Active current 9.5->10.1 due to current limit: Active-LoadBalancing
2025-11-05T04:18:13.074Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.8% (10.1 A)
2025-11-05T04:18:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:18:24.410Z:INFO:taskMain.c:5996:Socket #1: Active current 10.1->10.5 due to current limit: Active-LoadBalancing
2025-11-05T04:18:25.191Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.4% (10.4 A)
2025-11-05T04:18:36.410Z:INFO:taskMain.c:5996:Socket #1: Active current 10.5->10.7 due to current limit: Active-LoadBalancing
2025-11-05T04:18:48.410Z:INFO:taskMain.c:5996:Socket #1: Active current 10.7->10.8 due to current limit: Active-LoadBalancing
2025-11-05T04:19:12.406Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->10.9 due to current limit: Active-LoadBalancing
2025-11-05T04:19:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:20:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:21:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:21:15.238Z:USER:taskMaster.c:6684:Socket #1: L1N=236.5V L2N=236.9V L3N=236.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T04:21:15.250Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T04:22:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:22:20.132Z:USER:taskMaster.c:6582:Temperature: 30.0 C
2025-11-05T04:23:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:24:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:24:40.515Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-05T04:25:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:26:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:27:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:28:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:29:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:30:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T04:30:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:31:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:32:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:33:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:34:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:34:40.453Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-05T04:35:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:36:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:36:15.144Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=236.3V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T04:36:15.156Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T04:37:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:37:20.535Z:USER:taskMaster.c:6582:Temperature: 28.4 C
2025-11-05T04:38:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:39:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:40:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:41:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:42:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:43:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:44:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:44:40.390Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-05T04:45:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T04:45:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:46:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:47:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:48:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:49:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:50:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:51:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:51:15.058Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=236.7V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T04:51:15.070Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T04:52:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:52:20.890Z:USER:taskMaster.c:6582:Temperature: 27.1 C
2025-11-05T04:53:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:54:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:54:40.328Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-05T04:55:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:56:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:57:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:58:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T04:59:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:00:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T05:00:12.148Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->12.6 due to current limit: Active-LoadBalancing
2025-11-05T05:00:12.757Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-11-05T05:00:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:00:15.941Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000018, address 0x00018000 (1)
2025-11-05T05:00:15.953Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-05T05:00:24.144Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->13.6 due to current limit: Active-LoadBalancing
2025-11-05T05:00:24.875Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.5% (13.5 A)
2025-11-05T05:00:36.144Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->14.1 due to current limit: Active-LoadBalancing
2025-11-05T05:00:36.996Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.5% (14.1 A)
2025-11-05T05:00:45.343Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-05T05:00:45.351Z:INFO:db_chargingprofi:26: socket 0
2025-11-05T05:00:45.359Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-05T05:00:45.367Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-05T05:00:45.375Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-05T05:00:45.382Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-05T05:00:45.394Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-05T05:00:45.402Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-05T05:00:45.410Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-05T05:00:45.421Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-05T05:00:45.429Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-05T05:00:45.437Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-05T05:00:45.445Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-05T05:00:45.453Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-05T05:00:45.460Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-05T05:00:45.468Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-05T05:00:45.476Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-05T05:00:45.488Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-05T05:00:45.496Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-05T05:00:45.503Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-05T05:00:45.511Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-05T05:00:45.519Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-05T05:00:45.527Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-05T05:00:48.144Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.5 due to current limit: Active-LoadBalancing
2025-11-05T05:00:49.113Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-05T05:01:00.140Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-05T05:01:06.035Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-05T05:01:06.046Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-05T05:01:06.054Z:USER:taskMaster.c:6684:Socket #1: L1N=235.6V L2N=236.1V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:01:06.066Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:01:06.078Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-05T05:01:06.085Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-05T05:01:06.093Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-05T05:01:06.281Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-05T05:01:06.437Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-05T05:01:06.445Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-05T05:01:06.453Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-05T05:01:06.464Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-05T05:01:07.292Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-05T05:01:07.441Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-05T05:01:12.140Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-05T05:01:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:01:36.082Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=235.5V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:01:36.093Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:01:36.136Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-05T05:02:06.015Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-05T05:02:06.078Z:USER:taskMaster.c:6684:Socket #1: L1N=234.9V L2N=235.4V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:02:06.089Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:02:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:02:36.078Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=235.1V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:02:36.089Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:03:06.074Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=235.0V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:03:06.085Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:03:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:03:36.070Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=234.8V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:03:36.082Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:04:06.066Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=234.3V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:04:06.078Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:04:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:04:36.062Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=234.1V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:04:36.074Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:04:36.121Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-05T05:04:36.488Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-05T05:04:40.261Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(15.0 15.0 14.6)A
2025-11-05T05:04:48.117Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T05:05:00.117Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-05T05:05:06.062Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.5V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:05:06.074Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:05:12.117Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-05T05:05:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:05:36.058Z:USER:taskMaster.c:6684:Socket #1: L1N=234.3V L2N=234.7V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:05:36.070Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:05:36.113Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-05T05:06:06.054Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=234.7V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:06:06.066Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:06:06.078Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-05T05:06:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:07:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:07:21.296Z:USER:taskMaster.c:6582:Temperature: 26.2 C
2025-11-05T05:08:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:09:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:10:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:11:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:12:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:13:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:13:48.062Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-05T05:13:48.902Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-05T05:14:00.058Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T05:14:12.058Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-05T05:14:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:14:24.058Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-05T05:14:40.199Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 14.9)A
2025-11-05T05:14:48.054Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-05T05:15:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T05:15:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:16:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:17:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:18:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:19:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:20:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:21:05.960Z:USER:taskMaster.c:6684:Socket #1: L1N=233.2V L2N=233.4V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:21:05.972Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:21:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:22:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:22:21.652Z:USER:taskMaster.c:6582:Temperature: 25.8 C
2025-11-05T05:23:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:24:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:24:40.136Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-05T05:25:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:26:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:27:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:28:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:29:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:30:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T05:30:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:31:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:32:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:33:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:34:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:34:25.921Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-05T05:34:26.191Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-05T05:34:31.824Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-05T05:34:31.835Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-05T05:34:40.074Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-05T05:35:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:36:05.863Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=235.4V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:36:05.875Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:36:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:37:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:37:22.007Z:USER:taskMaster.c:6582:Temperature: 25.6 C
2025-11-05T05:38:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:39:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:40:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:41:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:42:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:43:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:44:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:44:40.011Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-05T05:45:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T05:45:15.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:46:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:47:11.898Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-05T05:47:12.531Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-05T05:47:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:47:23.898Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-05T05:47:35.898Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-05T05:47:59.894Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-05T05:48:15.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:49:11.886Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-05T05:49:12.707Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-05T05:49:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:49:23.886Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-05T05:49:35.886Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-05T05:49:59.882Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-05T05:50:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:50:23.878Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-05T05:50:24.410Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-05T05:50:35.878Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->12.7 due to current limit: Active-LoadBalancing
2025-11-05T05:50:36.527Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.2% (12.7 A)
2025-11-05T05:50:47.878Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->11.6 due to current limit: Active-LoadBalancing
2025-11-05T05:50:48.648Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.4% (11.6 A)
2025-11-05T05:50:59.875Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.0 due to current limit: Active-LoadBalancing
2025-11-05T05:51:00.765Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.3% (11.0 A)
2025-11-05T05:51:05.769Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=237.3V L3N=236.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:51:05.781Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:51:11.875Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->10.6 due to current limit: Active-LoadBalancing
2025-11-05T05:51:11.886Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.6% (10.6 A)
2025-11-05T05:51:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:51:17.167Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-05T05:51:17.179Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-05T05:51:17.187Z:USER:taskMaster.c:6684:Socket #1: L1N=235.8V L2N=237.1V L3N=236.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:51:17.199Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:51:17.226Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-05T05:51:17.234Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-05T05:51:17.242Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-05T05:51:17.566Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-05T05:51:17.578Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-05T05:51:17.585Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-05T05:51:17.597Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-05T05:51:18.574Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-05T05:51:23.875Z:INFO:taskMain.c:5996:Socket #1: Active current 10.6->10.4 due to current limit: Active-LoadBalancing
2025-11-05T05:51:35.871Z:INFO:taskMain.c:5996:Socket #1: Active current 10.4->10.2 due to current limit: Active-LoadBalancing
2025-11-05T05:51:47.214Z:USER:taskMaster.c:6684:Socket #1: L1N=236.0V L2N=237.4V L3N=236.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:51:47.226Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:51:59.871Z:INFO:taskMain.c:5996:Socket #1: Active current 10.1->10.1 due to current limit: Active-LoadBalancing
2025-11-05T05:52:11.867Z:INFO:taskMain.c:5996:Socket #1: Active current 10.1->12.0 due to current limit: Active-LoadBalancing
2025-11-05T05:52:12.097Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.0% (12.0 A)
2025-11-05T05:52:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:52:17.156Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-05T05:52:17.210Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=237.0V L3N=236.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:52:17.222Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:52:22.410Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-05T05:52:23.867Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->13.2 due to current limit: Active-LoadBalancing
2025-11-05T05:52:24.218Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.0% (13.2 A)
2025-11-05T05:52:35.867Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.9 due to current limit: Active-LoadBalancing
2025-11-05T05:52:36.335Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.2% (13.9 A)
2025-11-05T05:52:47.207Z:USER:taskMaster.c:6684:Socket #1: L1N=235.6V L2N=236.4V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:52:47.222Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:52:47.863Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->14.4 due to current limit: Active-LoadBalancing
2025-11-05T05:52:48.453Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.9% (14.3 A)
2025-11-05T05:52:59.863Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-05T05:53:11.863Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-05T05:53:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:53:17.207Z:USER:taskMaster.c:6684:Socket #1: L1N=235.9V L2N=236.6V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:53:17.218Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:53:35.859Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-05T05:53:47.203Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=236.4V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:53:47.214Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:54:11.855Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->11.0 due to current limit: Active-LoadBalancing
2025-11-05T05:54:12.277Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.3% (11.0 A)
2025-11-05T05:54:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:54:17.199Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=236.5V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:54:17.210Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:54:23.855Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->9.0 due to current limit: Active-LoadBalancing
2025-11-05T05:54:24.394Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.9% (8.9 A)
2025-11-05T05:54:35.851Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->7.8 due to current limit: Active-LoadBalancing
2025-11-05T05:54:36.511Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.9% (7.7 A)
2025-11-05T05:54:39.945Z:INFO:active_lb.c:308:SMt:(10.0 1.0 1.0)A Free:(6.0 15.0 15.0)A ALB:(7.8 15.0 15.0)A
2025-11-05T05:54:47.195Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=236.5V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:54:47.207Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:54:47.851Z:INFO:taskMain.c:5996:Socket #1: Active current 7.8->7.1 due to current limit: Active-LoadBalancing
2025-11-05T05:54:48.632Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.7% (7.0 A)
2025-11-05T05:54:59.851Z:INFO:taskMain.c:5996:Socket #1: Active current 7.1->6.6 due to current limit: Active-LoadBalancing
2025-11-05T05:55:00.750Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.0% (6.6 A)
2025-11-05T05:55:11.847Z:INFO:taskMain.c:5996:Socket #1: Active current 6.6->6.4 due to current limit: Active-LoadBalancing
2025-11-05T05:55:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:55:17.195Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=236.4V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:55:17.207Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:55:23.847Z:INFO:taskMain.c:5996:Socket #1: Active current 6.4->6.2 due to current limit: Active-LoadBalancing
2025-11-05T05:55:47.191Z:USER:taskMaster.c:6684:Socket #1: L1N=235.1V L2N=236.7V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:55:47.203Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:55:47.847Z:INFO:taskMain.c:5996:Socket #1: Active current 6.1->6.1 due to current limit: Active-LoadBalancing
2025-11-05T05:56:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:56:17.187Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=236.5V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T05:56:17.199Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T05:56:17.210Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-05T05:57:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:57:59.832Z:INFO:taskMain.c:5996:Socket #1: Active current 6.0->8.4 due to current limit: Active-LoadBalancing
2025-11-05T05:58:00.511Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.0% (8.4 A)
2025-11-05T05:58:11.832Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->9.8 due to current limit: Active-LoadBalancing
2025-11-05T05:58:12.628Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.4% (9.8 A)
2025-11-05T05:58:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:58:23.828Z:INFO:taskMain.c:5996:Socket #1: Active current 9.8->10.7 due to current limit: Active-LoadBalancing
2025-11-05T05:58:24.750Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.8% (10.7 A)
2025-11-05T05:58:35.828Z:INFO:taskMain.c:5996:Socket #1: Active current 10.7->11.2 due to current limit: Active-LoadBalancing
2025-11-05T05:58:35.859Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.7% (11.2 A)
2025-11-05T05:58:47.828Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.5 due to current limit: Active-LoadBalancing
2025-11-05T05:58:59.824Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-05T05:59:11.824Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.8 due to current limit: Active-LoadBalancing
2025-11-05T05:59:15.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T05:59:35.820Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.9 due to current limit: Active-LoadBalancing
2025-11-05T06:00:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T06:00:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T06:00:52.863Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-05T06:00:52.871Z:INFO:db_chargingprofi:26: socket 0
2025-11-05T06:00:52.878Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-05T06:00:52.886Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-05T06:00:52.894Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-05T06:00:52.902Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-05T06:00:52.914Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-05T06:00:52.921Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-05T06:00:52.929Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-05T06:00:52.937Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-05T06:00:52.949Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-05T06:00:52.957Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-05T06:00:52.964Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-05T06:00:52.972Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-05T06:00:52.980Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-05T06:00:52.988Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-05T06:00:52.996Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-05T06:00:53.007Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-05T06:00:53.015Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-05T06:00:53.023Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-05T06:00:53.031Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-05T06:00:53.039Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-05T06:00:53.046Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-05T06:01:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T06:01:59.804Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->11.6 due to current limit: Active-LoadBalancing
2025-11-05T06:01:59.855Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.3% (11.6 A)
2025-11-05T06:02:11.804Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-05T06:02:15.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T06:02:15.550Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000019, address 0x00019000 (1)
2025-11-05T06:02:15.558Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-05T06:02:23.804Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-05T06:02:47.800Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.1 due to current limit: Active-LoadBalancing
2025-11-05T06:03:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T06:03:23.796Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.4 due to current limit: Active-LoadBalancing
2025-11-05T06:03:24.687Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.0% (11.4 A)
2025-11-05T06:03:35.796Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-05T06:03:47.796Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.8 due to current limit: Active-LoadBalancing
2025-11-05T06:04:11.792Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.9 due to current limit: Active-LoadBalancing
2025-11-05T06:04:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T06:04:35.789Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->9.6 due to current limit: Active-LoadBalancing
2025-11-05T06:04:36.390Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.9% (9.5 A)
2025-11-05T06:04:39.882Z:INFO:active_lb.c:308:SMt:(10.0 1.0 2.0)A Free:(6.0 15.0 14.0)A ALB:(9.6 15.0 14.0)A
2025-11-05T06:04:47.789Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->8.1 due to current limit: Active-LoadBalancing
2025-11-05T06:04:48.507Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.5% (8.1 A)
2025-11-05T06:04:59.789Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->9.7 due to current limit: Active-LoadBalancing
2025-11-05T06:05:00.628Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.1% (9.7 A)
2025-11-05T06:05:11.785Z:INFO:taskMain.c:5996:Socket #1: Active current 9.7->10.2 due to current limit: Active-LoadBalancing
2025-11-05T06:05:12.746Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.0% (10.2 A)
2025-11-05T06:05:15.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T06:05:16.679Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-05T06:05:16.687Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-05T06:05:16.699Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=233.3V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T06:05:16.710Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T06:05:16.722Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-05T06:05:16.730Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-05T06:05:16.738Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-05T06:05:16.785Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-05T06:05:17.078Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-05T06:05:17.089Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-05T06:05:17.097Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-05T06:05:17.105Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-05T06:05:17.796Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-05T06:05:18.105Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-05T06:05:23.785Z:INFO:taskMain.c:5996:Socket #1: Active current 10.2->10.9 due to current limit: Active-LoadBalancing
2025-11-05T06:05:24.164Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.2% (10.9 A)
2025-11-05T06:05:35.785Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.4 due to current limit: Active-LoadBalancing
2025-11-05T06:05:36.285Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.9% (11.3 A)
2025-11-05T06:05:46.726Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=233.2V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T06:05:46.738Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T06:05:47.781Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-05T06:05:59.781Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-05T06:06:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T06:06:16.667Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-05T06:06:16.722Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=233.2V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T06:06:16.734Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T06:06:23.777Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.9 due to current limit: Active-LoadBalancing
2025-11-05T06:06:35.777Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.5 due to current limit: Active-LoadBalancing
2025-11-05T06:06:35.867Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.2% (11.5 A)
2025-11-05T06:06:43.671Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-05T06:06:43.679Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-05T06:06:43.687Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=233.3V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T06:06:43.699Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-05T06:06:43.710Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-05T06:06:43.722Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-05T06:06:43.730Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-05T06:06:43.945Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-05T06:06:44.675Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-05T06:06:47.777Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->10.7 due to current limit: Active-LoadBalancing
2025-11-05T06:06:47.789Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->17.8)
2025-11-05T06:06:48.714Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.8% (10.7 A)
2025-11-05T06:06:59.773Z:INFO:taskMain.c:5996:Socket #1: Active current 10.7->12.6 due to current limit: Active-LoadBalancing
2025-11-05T06:06:59.824Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-11-05T06:07:11.773Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->13.8 due to current limit: Active-LoadBalancing
2025-11-05T06:07:11.945Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.9% (13.7 A)
2025-11-05T06:07:13.718Z:USER:taskMaster.c:6684:Socket #1: L1N=235.6V L2N=235.9V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T06:07:13.730Z:USER:taskMaster.c:6720:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-11-05T06:07:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T06:07:22.765Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-05T06:07:23.773Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->14.4 due to current limit: Active-LoadBalancing
2025-11-05T06:07:24.062Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-05T06:07:43.660Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-05T06:07:43.714Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=235.1V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T06:07:43.726Z:USER:taskMaster.c:6720:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-11-05T06:07:59.769Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->12.6 due to current limit: Active-LoadBalancing
2025-11-05T06:07:59.781Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->21.0)
2025-11-05T06:08:00.417Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-11-05T06:08:11.765Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->13.8 due to current limit: Active-LoadBalancing
2025-11-05T06:08:12.539Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.9% (13.7 A)
2025-11-05T06:08:13.710Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=235.0V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T06:08:13.722Z:USER:taskMaster.c:6720:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-11-05T06:08:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T06:08:23.765Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.7 due to current limit: Active-LoadBalancing
2025-11-05T06:08:23.777Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.9->22.7)
2025-11-05T06:08:35.765Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->14.4 due to current limit: Active-LoadBalancing
2025-11-05T06:08:35.777Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.9% (14.3 A)
2025-11-05T06:08:43.707Z:USER:taskMaster.c:6684:Socket #1: L1N=235.1V L2N=235.3V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T06:08:43.718Z:USER:taskMaster.c:6720:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-11-05T06:09:13.703Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=235.1V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T06:09:13.718Z:USER:taskMaster.c:6720:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-11-05T06:09:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T06:09:23.757Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:09:43.703Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=234.7V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T06:09:43.714Z:USER:taskMaster.c:6720:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-11-05T06:09:47.757Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:09:59.757Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:10:11.753Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->13.9 due to current limit: Active-LoadBalancing
2025-11-05T06:10:11.765Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.0)
2025-11-05T06:10:12.714Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-05T06:10:13.699Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.3V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T06:10:13.710Z:USER:taskMaster.c:6720:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-11-05T06:10:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T06:10:23.753Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->14.1 due to current limit: Active-LoadBalancing
2025-11-05T06:10:35.753Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.3 due to current limit: Active-LoadBalancing
2025-11-05T06:10:43.695Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.7V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T06:10:43.707Z:USER:taskMaster.c:6720:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-11-05T06:10:59.750Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.4 due to current limit: Active-LoadBalancing
2025-11-05T06:11:13.691Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.4V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T06:11:13.703Z:USER:taskMaster.c:6720:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-11-05T06:11:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T06:11:43.687Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.2V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T06:11:43.699Z:USER:taskMaster.c:6720:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-11-05T06:11:43.710Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-05T06:11:47.746Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:11:59.742Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:12:04.542Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-11-05T06:12:11.742Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:12:15.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T06:12:23.742Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:12:35.738Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:12:47.738Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:12:59.738Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:13:15.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T06:13:23.734Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:14:11.730Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:14:15.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T06:14:23.726Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:14:35.726Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:14:39.820Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(15.5 15.5 14.5)A
2025-11-05T06:14:47.726Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:14:59.722Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:15:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T06:15:11.722Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:15:15.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T06:15:23.722Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:15:35.718Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:16:11.714Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:16:15.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T06:17:15.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T06:17:47.707Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.1 due to current limit: Active-LoadBalancing
2025-11-05T06:17:47.718Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.4)
2025-11-05T06:17:48.167Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.4% (14.0 A)
2025-11-05T06:17:59.707Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->13.9 due to current limit: Active-LoadBalancing
2025-11-05T06:17:59.718Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.4->23.0)
2025-11-05T06:18:11.703Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.7 due to current limit: Active-LoadBalancing
2025-11-05T06:18:11.714Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.0->22.8)
2025-11-05T06:18:15.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T06:18:23.703Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.8->22.6)
2025-11-05T06:18:35.703Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->14.0 due to current limit: Active-LoadBalancing
2025-11-05T06:18:36.640Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.2% (13.9 A)
2025-11-05T06:18:47.699Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.2 due to current limit: Active-LoadBalancing
2025-11-05T06:18:59.699Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.3 due to current limit: Active-LoadBalancing
2025-11-05T06:19:15.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-05T06:19:23.695Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.4 due to current limit: Active-LoadBalancing
2025-11-05T06:19:59.691Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->24.1)
2025-11-05T06:20:03.085Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-05T06:20:03.097Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-05T06:20:03.105Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-05T06:20:03.113Z:WARNING:taskMain.c:4758:Socket #1: EV disconnected while charging (12.3V)
2025-11-05T06:20:03.125Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-05T06:20:03.136Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAIT_FOR_EV_RECONNECT
2025-11-05T06:20:03.148Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_A
2025-11-05T06:20:03.492Z:INFO:taskMain.c:6494:Socket #1: CPhigh 12.4 V
2025-11-05T06:20:03.500Z:INFO:taskMain.c:6499:Socket #1: CPlow 12.4 V
2025-11-05T06:20:04.140Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAIT_FOR_EV_RECONNECT, CP: 12.4/12.4, tag: 04BB2
2025-11-05T06:20:04.140Z:INFO:taskMain.c:1417:9EAFD0F94
2025-11-05T06:20:09.851Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->0.0 due to current limit: Cable
2025-11-05T06:20:09.886Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_TERMINATING
2025-11-05T06:20:09.894Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_VEHICLE
2025-11-05T06:20:09.933Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-05T06:20:10.203Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-05T06:20:10.207Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-05T06:20:10.214Z:INFO:taskMain.c:6504:Socket #1: PP 34464 Ohm (0 A)
2025-11-05T06:20:10.921Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_TERMINATING, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-05T06:20:13.933Z:INFO:taskMaster.c:4957:Socket #1: state main : WAIT_FOR_STOP_METERVALUE
2025-11-05T06:20:14.179Z:INFO:taskMain.c:938:Socket #1: charging session status set inactive
2025-11-05T06:20:14.191Z:INFO:taskMaster.c:4957:Socket #1: state main : WAIT_FOR_DISCONNECT
2025-11-05T06:20:14.199Z:USER:board_ng9xx.c:5068:Socket #1: unlock socket motor
2025-11-05T06:20:14.636Z:INFO:db_transaction.c:16:Added TransactionStop for socket 1 at 0x000194c3 (ts: 2025-11-05 06:20:14)
2025-11-05T06:20:14.648Z:INFO:db_transaction.c:16:Updated TransactionStart for socket 1 at 0x0000b49c (ts: 2025-11-04 16:05:14)
2025-11-05T06:20:14.710Z:INFO:taskMaster.c:4979:Socket #1: state led : AVAILABLE
2025-11-05T06:20:14.765Z:INFO:taskMaster.c:4957:Socket #1: state main : AVAILABLE
2025-11-05T06:20:14.781Z:INFO:taskMain.c:6440:Socket #1: active tag cleared
2025-11-05T06:20:15.699Z:INFO:taskMain.c:1419:Socket #1: main state: AVAILABLE, CP: 0.0/0.0, no tag
2025-11-05T06:22:04.476Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-11-05T06:22:23.171Z:USER:taskMaster.c:6582:Temperature: 26.2 C
2025-11-05T06:24:39.757Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-05T06:26:43.593Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=235.1V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T06:30:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T06:32:04.515Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-11-05T06:34:39.695Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(12.4 15.0 15.0)A
2025-11-05T06:37:23.527Z:USER:taskMaster.c:6582:Temperature: 25.6 C
2025-11-05T06:41:43.500Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=233.2V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T06:44:39.628Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-05T06:45:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T06:52:23.882Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-05T06:54:39.566Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.6 15.0 15.0)A
2025-11-05T06:56:43.402Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=235.5V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T07:00:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T07:04:39.503Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-05T07:07:24.238Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-05T07:11:43.308Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=234.8V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T07:14:39.441Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-05T07:15:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T07:22:24.593Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-05T07:24:39.378Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.4 15.0)A
2025-11-05T07:26:43.214Z:USER:taskMaster.c:6684:Socket #1: L1N=235.7V L2N=236.1V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T07:30:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T07:34:31.062Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-05T07:34:31.074Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-05T07:34:39.312Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-05T07:37:24.996Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-05T07:41:43.121Z:USER:taskMaster.c:6684:Socket #1: L1N=236.5V L2N=237.1V L3N=236.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T07:44:39.250Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-05T07:45:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T07:52:25.402Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-05T07:54:39.187Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-05T07:56:43.023Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=236.8V L3N=236.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T08:00:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T08:04:39.125Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-05T08:07:25.757Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-05T08:11:42.929Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=236.5V L3N=237.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T08:14:39.062Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(15.7 15.0 15.0)A
2025-11-05T08:15:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T08:22:26.164Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-05T08:24:38.996Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(14.9 14.0 15.0)A
2025-11-05T08:26:42.835Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=235.0V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T08:30:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T08:34:38.933Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.3 15.0 15.0)A
2025-11-05T08:37:26.566Z:USER:taskMaster.c:6582:Temperature: 25.6 C
2025-11-05T08:41:42.738Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.0V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T08:44:38.871Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-05T08:45:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T08:52:26.972Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-05T08:54:38.808Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(16.3 15.0 15.0)A
2025-11-05T08:56:42.644Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=234.6V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T09:00:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T09:04:38.746Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.1 14.0 15.0)A
2025-11-05T09:07:27.328Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-05T09:11:42.550Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=235.3V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T09:14:38.679Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(16.2 14.0 15.0)A
2025-11-05T09:15:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T09:22:27.683Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-05T09:24:38.617Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(16.2 15.0 15.0)A
2025-11-05T09:26:42.453Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=236.9V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T09:30:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T09:34:24.234Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-05T09:34:24.500Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-05T09:34:30.304Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-05T09:34:30.316Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-05T09:34:38.554Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-05T09:34:38.605Z:INFO:comFaults.c:482:Reset fault status
2025-11-05T09:37:28.085Z:USER:taskMaster.c:6582:Temperature: 25.9 C
2025-11-05T09:41:42.359Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=235.1V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T09:44:38.492Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-05T09:45:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T09:52:28.492Z:USER:taskMaster.c:6582:Temperature: 26.1 C
2025-11-05T09:54:38.429Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(15.8 15.0 15.0)A
2025-11-05T09:56:42.265Z:USER:taskMaster.c:6684:Socket #1: L1N=234.3V L2N=235.5V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T10:00:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T10:04:38.363Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-05T10:07:28.847Z:USER:taskMaster.c:6582:Temperature: 26.2 C
2025-11-05T10:11:42.167Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=236.5V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T10:14:38.300Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(16.7 15.0 15.0)A
2025-11-05T10:15:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T10:22:29.253Z:USER:taskMaster.c:6582:Temperature: 26.8 C
2025-11-05T10:24:38.238Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.3 15.0)A
2025-11-05T10:26:42.074Z:USER:taskMaster.c:6684:Socket #1: L1N=236.7V L2N=237.7V L3N=236.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T10:30:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T10:34:38.175Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-05T10:37:29.605Z:USER:taskMaster.c:6582:Temperature: 27.1 C
2025-11-05T10:41:41.980Z:USER:taskMaster.c:6684:Socket #1: L1N=238.0V L2N=239.5V L3N=238.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T10:44:38.113Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(16.6 17.0 15.0)A
2025-11-05T10:45:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T10:52:30.011Z:USER:taskMaster.c:6582:Temperature: 27.5 C
2025-11-05T10:54:38.046Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-05T10:56:41.886Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=236.6V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T11:00:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T11:04:37.984Z:INFO:active_lb.c:308:SMt:(-1.0 9.0 1.0)A Free:(17.0 7.0 15.0)A ALB:(16.6 7.0 15.0)A
2025-11-05T11:07:30.367Z:USER:taskMaster.c:6582:Temperature: 27.5 C
2025-11-05T11:11:41.789Z:USER:taskMaster.c:6684:Socket #1: L1N=236.6V L2N=235.6V L3N=236.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T11:14:37.921Z:INFO:active_lb.c:308:SMt:(-1.0 9.0 1.0)A Free:(17.0 7.0 15.0)A ALB:(16.6 7.0 15.0)A
2025-11-05T11:15:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T11:22:30.773Z:USER:taskMaster.c:6582:Temperature: 28.0 C
2025-11-05T11:24:37.859Z:INFO:active_lb.c:308:SMt:(-2.0 7.0 1.0)A Free:(18.0 9.0 15.0)A ALB:(18.0 9.3 15.0)A
2025-11-05T11:26:41.695Z:USER:taskMaster.c:6684:Socket #1: L1N=237.7V L2N=237.5V L3N=238.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T11:30:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T11:34:29.542Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-05T11:34:29.554Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-05T11:34:37.796Z:INFO:active_lb.c:308:SMt:(-2.0 -3.0 1.0)A Free:(18.0 19.0 15.0)A ALB:(18.0 19.0 15.0)A
2025-11-05T11:37:31.179Z:USER:taskMaster.c:6582:Temperature: 28.5 C
2025-11-05T11:41:41.601Z:USER:taskMaster.c:6684:Socket #1: L1N=238.3V L2N=238.9V L3N=239.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T11:44:37.730Z:INFO:active_lb.c:308:SMt:(-1.0 -3.0 1.0)A Free:(17.0 19.0 15.0)A ALB:(17.6 19.0 15.0)A
2025-11-05T11:45:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T11:52:31.582Z:USER:taskMaster.c:6582:Temperature: 28.6 C
2025-11-05T11:54:37.667Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(18.0 18.0 15.0)A ALB:(18.0 18.4 15.0)A
2025-11-05T11:56:41.503Z:USER:taskMaster.c:6684:Socket #1: L1N=236.2V L2N=236.1V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T12:00:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T12:04:37.605Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.6 17.6 15.0)A
2025-11-05T12:07:31.937Z:USER:taskMaster.c:6582:Temperature: 29.1 C
2025-11-05T12:11:41.410Z:USER:taskMaster.c:6684:Socket #1: L1N=236.0V L2N=235.9V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T12:14:37.542Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.4 15.0)A
2025-11-05T12:15:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T12:22:32.292Z:USER:taskMaster.c:6582:Temperature: 29.1 C
2025-11-05T12:24:37.476Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.2 17.0 15.0)A
2025-11-05T12:26:41.316Z:USER:taskMaster.c:6684:Socket #1: L1N=238.7V L2N=238.6V L3N=239.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T12:30:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T12:34:37.414Z:INFO:active_lb.c:308:SMt:(-2.0 -3.0 1.0)A Free:(18.0 19.0 15.0)A ALB:(17.6 18.8 15.0)A
2025-11-05T12:37:32.695Z:USER:taskMaster.c:6582:Temperature: 29.2 C
2025-11-05T12:41:41.218Z:USER:taskMaster.c:6684:Socket #1: L1N=236.2V L2N=236.4V L3N=237.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T12:44:37.351Z:INFO:active_lb.c:308:SMt:(-2.0 -3.0 1.0)A Free:(18.0 19.0 15.0)A ALB:(18.0 19.0 15.0)A
2025-11-05T12:45:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T12:52:33.101Z:USER:taskMaster.c:6582:Temperature: 29.5 C
2025-11-05T12:54:37.289Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 1.0)A Free:(17.0 14.0 15.0)A ALB:(15.8 14.6 15.0)A
2025-11-05T12:56:41.125Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=235.1V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T13:00:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T13:04:37.226Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.3 13.9 15.0)A
2025-11-05T13:07:33.457Z:USER:taskMaster.c:6582:Temperature: 29.6 C
2025-11-05T13:11:41.031Z:USER:taskMaster.c:6684:Socket #1: L1N=237.4V L2N=237.9V L3N=237.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T13:14:37.160Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-05T13:15:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T13:22:33.863Z:USER:taskMaster.c:6582:Temperature: 29.5 C
2025-11-05T13:24:37.097Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-05T13:26:40.933Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=236.3V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T13:30:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T13:34:22.472Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-05T13:34:22.742Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-05T13:34:28.785Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-05T13:34:28.796Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-05T13:34:37.035Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-05T13:37:34.214Z:USER:taskMaster.c:6582:Temperature: 29.4 C
2025-11-05T13:41:40.839Z:USER:taskMaster.c:6684:Socket #1: L1N=238.0V L2N=238.3V L3N=238.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T13:44:36.972Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-05T13:45:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T13:52:34.621Z:USER:taskMaster.c:6582:Temperature: 29.5 C
2025-11-05T13:54:36.910Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-05T13:56:40.746Z:USER:taskMaster.c:6684:Socket #1: L1N=238.3V L2N=239.8V L3N=239.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T14:00:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T14:04:36.843Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-05T14:07:35.027Z:USER:taskMaster.c:6582:Temperature: 29.5 C
2025-11-05T14:11:40.648Z:USER:taskMaster.c:6684:Socket #1: L1N=236.6V L2N=237.5V L3N=237.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T14:14:36.781Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(16.7 15.0 15.0)A
2025-11-05T14:15:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T14:22:35.382Z:USER:taskMaster.c:6582:Temperature: 29.4 C
2025-11-05T14:24:36.718Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(15.0 17.0 15.0)A ALB:(15.1 17.0 15.0)A
2025-11-05T14:26:40.605Z:USER:taskMaster.c:6684:Socket #1: L1N=236.9V L2N=237.6V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T14:30:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T14:34:36.656Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-05T14:37:35.785Z:USER:taskMaster.c:6582:Temperature: 29.1 C
2025-11-05T14:41:40.558Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.6V L3N=231.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T14:44:36.589Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-05T14:45:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T14:52:36.140Z:USER:taskMaster.c:6582:Temperature: 28.9 C
2025-11-05T14:54:36.527Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-05T14:56:40.464Z:USER:taskMaster.c:6684:Socket #1: L1N=233.4V L2N=234.3V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T15:00:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T15:04:36.464Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-05T15:07:36.546Z:USER:taskMaster.c:6582:Temperature: 28.9 C
2025-11-05T15:11:40.371Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.9V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T15:14:36.402Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-05T15:15:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T15:22:36.953Z:USER:taskMaster.c:6582:Temperature: 28.9 C
2025-11-05T15:24:36.339Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.3 14.1 15.0)A
2025-11-05T15:26:40.273Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=235.3V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T15:30:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T15:34:28.023Z:INFO:heap_trace.c:493:free: 57240/160768 (35.6%) min: 37040 (23.0%) alloc #: 207
2025-11-05T15:34:28.035Z:INFO:heap_trace.c:495:fragm: 28.4% 4K: 14.1% free blocks: # 17 largest: 40992
2025-11-05T15:34:36.273Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 12.9 15.0)A
2025-11-05T15:37:37.304Z:USER:taskMaster.c:6582:Temperature: 28.8 C
2025-11-05T15:41:40.179Z:USER:taskMaster.c:6684:Socket #1: L1N=234.3V L2N=234.5V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T15:44:36.210Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-05T15:45:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T15:52:37.710Z:USER:taskMaster.c:6582:Temperature: 28.4 C
2025-11-05T15:54:36.148Z:INFO:active_lb.c:308:SMt:(2.0 4.0 1.0)A Free:(14.0 12.0 15.0)A ALB:(14.1 12.6 15.0)A
2025-11-05T15:56:40.085Z:USER:taskMaster.c:6684:Socket #1: L1N=231.6V L2N=232.1V L3N=230.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T16:00:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T16:04:36.085Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-05T16:05:19.429Z:INFO:taskMaster.c:6376:Socket #1: no schedule
2025-11-05T16:05:19.437Z:USER:taskMaster.c:6402:Socket #1: external current limit 16.0 A
2025-11-05T16:07:37.667Z:USER:taskMaster.c:6582:Temperature: 28.2 C
2025-11-05T16:11:39.992Z:USER:taskMaster.c:6684:Socket #1: L1N=237.1V L2N=237.0V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T16:13:06.636Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-11-05T16:14:36.023Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.6 13.6 15.0)A
2025-11-05T16:15:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T16:22:38.070Z:USER:taskMaster.c:6582:Temperature: 27.9 C
2025-11-05T16:23:06.574Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-11-05T16:23:57.027Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x7880)
2025-11-05T16:23:57.039Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-05T16:23:57.062Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-05T16:23:58.312Z:WARNING:taskWebClient.c:810:TLS handshake failed (-0x50) for fd=1
2025-11-05T16:23:58.320Z:WARNING:taskWebClient.c:834:Failed to setup WebClient -80
2025-11-05T16:23:59.562Z:WARNING:taskWebClient.c:810:TLS handshake failed (-0x4e) for fd=1
2025-11-05T16:23:59.574Z:WARNING:taskWebClient.c:834:Failed to setup WebClient -78
2025-11-05T16:24:08.492Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-05T16:24:08.781Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-05T16:24:09.121Z:SECURITY:httpd_login.c:155:WebClient - connected (account: admin)
2025-11-05T16:24:09.226Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-05T16:24:09.582Z:SECURITY:web_functionalit:68:Changed '2059_00' from 1762359885345 => 1762359869161
2025-11-05T16:24:29.000Z:SECURITY:taskTime.c:603:Time changed
2025-11-05T16:24:55.363Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-05T16:25:19.722Z:WARNING:taskWebClient.c:234:Client (fd=1) disconnected (r: -0x50)
2025-11-05T16:25:19.734Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-05T16:25:19.808Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-05T16:26:59.351Z:USER:taskMaster.c:6684:Socket #1: L1N=230.3V L2N=230.1V L3N=230.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T16:30:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T16:33:06.617Z:INFO:taskLeds.c:338:Brightness set to 8%
2025-11-05T16:34:55.300Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(14.9 14.0 15.0)A
2025-11-05T16:37:57.382Z:USER:taskMaster.c:6582:Temperature: 27.5 C
2025-11-05T16:41:59.257Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=233.0V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T16:44:55.238Z:INFO:active_lb.c:308:SMt:(2.0 3.0 2.0)A Free:(14.0 13.0 14.0)A ALB:(14.4 13.0 14.0)A
2025-11-05T16:45:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T16:52:57.789Z:USER:taskMaster.c:6582:Temperature: 27.6 C
2025-11-05T16:54:55.175Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(15.0 15.0 14.0)A
2025-11-05T16:56:59.164Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=231.2V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T17:00:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T17:04:55.113Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-05T17:07:58.191Z:USER:taskMaster.c:6582:Temperature: 27.5 C
2025-11-05T17:11:59.066Z:USER:taskMaster.c:6684:Socket #1: L1N=234.3V L2N=233.1V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T17:14:55.046Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.0 15.0 15.0)A
2025-11-05T17:15:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T17:22:58.648Z:USER:taskMaster.c:6582:Temperature: 27.2 C
2025-11-05T17:24:54.984Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.0 14.0 15.0)A
2025-11-05T17:26:58.972Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=231.4V L3N=230.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T17:30:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T17:34:40.140Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-05T17:34:40.410Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-05T17:34:46.671Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-05T17:34:46.683Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-05T17:34:54.921Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.0 13.6 15.0)A
2025-11-05T17:37:59.101Z:USER:taskMaster.c:6582:Temperature: 27.1 C
2025-11-05T17:41:58.878Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.1V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T17:44:54.859Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.0 13.5 14.9)A
2025-11-05T17:45:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T17:52:59.507Z:USER:taskMaster.c:6582:Temperature: 27.0 C
2025-11-05T17:54:54.796Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.8 14.8 15.0)A
2025-11-05T17:56:58.781Z:USER:taskMaster.c:6684:Socket #1: L1N=231.1V L2N=232.0V L3N=231.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T18:00:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T18:04:54.734Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-05T18:07:59.914Z:USER:taskMaster.c:6582:Temperature: 26.9 C
2025-11-05T18:11:58.687Z:USER:taskMaster.c:6684:Socket #1: L1N=231.2V L2N=231.6V L3N=230.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T18:14:54.667Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.1 15.0)A
2025-11-05T18:15:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T18:23:00.320Z:USER:taskMaster.c:6582:Temperature: 26.6 C
2025-11-05T18:24:54.605Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 14.6)A
2025-11-05T18:26:58.593Z:USER:taskMaster.c:6684:Socket #1: L1N=231.9V L2N=232.8V L3N=231.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T18:30:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T18:34:54.542Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.0 14.0 14.6)A
2025-11-05T18:38:00.722Z:USER:taskMaster.c:6582:Temperature: 26.6 C
2025-11-05T18:41:58.500Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=233.8V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T18:44:54.480Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-05T18:45:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T18:53:01.179Z:USER:taskMaster.c:6582:Temperature: 26.4 C
2025-11-05T18:54:54.417Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(14.0 13.0 15.0)A ALB:(14.1 13.0 15.0)A
2025-11-05T18:56:58.402Z:USER:taskMaster.c:6684:Socket #1: L1N=235.8V L2N=235.0V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T19:00:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T19:04:54.351Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-11-05T19:08:01.585Z:USER:taskMaster.c:6582:Temperature: 26.1 C
2025-11-05T19:11:58.308Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=235.0V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T19:14:54.289Z:INFO:active_lb.c:308:SMt:(2.0 4.0 1.0)A Free:(14.0 12.0 15.0)A ALB:(14.0 12.1 15.0)A
2025-11-05T19:15:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T19:23:01.988Z:USER:taskMaster.c:6582:Temperature: 26.2 C
2025-11-05T19:24:54.226Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(14.0 13.0 15.0)A ALB:(14.0 13.0 15.0)A
2025-11-05T19:26:58.214Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.8V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T19:30:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T19:34:45.914Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-05T19:34:45.925Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-05T19:34:54.164Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-05T19:38:02.445Z:USER:taskMaster.c:6582:Temperature: 25.9 C
2025-11-05T19:41:58.117Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=235.0V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T19:44:54.101Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-05T19:45:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T19:53:02.847Z:USER:taskMaster.c:6582:Temperature: 25.8 C
2025-11-05T19:54:54.039Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 12.2 15.0)A
2025-11-05T19:56:58.023Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=235.2V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T20:00:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T20:04:53.972Z:INFO:active_lb.c:308:SMt:(1.0 5.0 1.0)A Free:(15.0 11.0 15.0)A ALB:(15.0 11.0 15.0)A
2025-11-05T20:08:03.253Z:USER:taskMaster.c:6582:Temperature: 25.8 C
2025-11-05T20:11:57.929Z:USER:taskMaster.c:6684:Socket #1: L1N=236.6V L2N=235.9V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T20:14:53.910Z:INFO:active_lb.c:308:SMt:(1.0 5.0 1.0)A Free:(15.0 11.0 15.0)A ALB:(15.0 11.0 15.0)A
2025-11-05T20:15:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T20:23:03.660Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-05T20:24:53.847Z:INFO:active_lb.c:308:SMt:(1.0 5.0 1.0)A Free:(15.0 11.0 15.0)A ALB:(15.0 11.0 15.0)A
2025-11-05T20:26:57.835Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=233.9V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T20:30:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T20:34:53.785Z:INFO:active_lb.c:308:SMt:(1.0 5.0 1.0)A Free:(15.0 11.0 15.0)A ALB:(15.0 11.0 15.0)A
2025-11-05T20:38:04.113Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-05T20:41:57.738Z:USER:taskMaster.c:6684:Socket #1: L1N=234.9V L2N=233.9V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T20:44:53.722Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 11.9 15.0)A
2025-11-05T20:45:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T20:53:04.519Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-05T20:54:53.656Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 12.0 15.0)A
2025-11-05T20:56:57.644Z:USER:taskMaster.c:6684:Socket #1: L1N=235.9V L2N=235.5V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T21:00:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T21:04:53.593Z:INFO:active_lb.c:308:SMt:(1.0 5.0 1.0)A Free:(15.0 11.0 15.0)A ALB:(15.0 11.6 15.0)A
2025-11-05T21:08:04.675Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-05T21:11:57.550Z:USER:taskMaster.c:6684:Socket #1: L1N=237.0V L2N=236.7V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T21:14:53.531Z:INFO:active_lb.c:308:SMt:(1.0 5.0 1.0)A Free:(15.0 11.0 15.0)A ALB:(15.0 10.8 15.0)A
2025-11-05T21:15:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T21:23:05.378Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-05T21:24:53.468Z:INFO:active_lb.c:308:SMt:(2.0 5.0 1.0)A Free:(14.0 11.0 15.0)A ALB:(14.1 11.0 15.0)A
2025-11-05T21:26:57.453Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=232.8V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T21:30:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T21:34:39.464Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-05T21:34:39.734Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-05T21:34:45.156Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-05T21:34:45.164Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-05T21:34:53.406Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 12.8 15.0)A
2025-11-05T21:34:53.464Z:INFO:comFaults.c:482:Reset fault status
2025-11-05T21:38:05.785Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-05T21:41:57.359Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=233.6V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T21:44:53.339Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 13.9 15.0)A
2025-11-05T21:45:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T21:53:06.238Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-05T21:54:53.277Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 14.7 15.0)A
2025-11-05T21:56:57.265Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=232.5V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T22:00:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T22:04:53.214Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-05T22:08:06.644Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-05T22:11:57.171Z:USER:taskMaster.c:6684:Socket #1: L1N=235.7V L2N=235.3V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T22:14:53.152Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 14.8 15.0)A
2025-11-05T22:15:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T22:23:07.101Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-05T22:24:53.089Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 14.8 15.0)A
2025-11-05T22:26:57.125Z:USER:taskMaster.c:6684:Socket #1: L1N=235.9V L2N=236.2V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T22:30:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T22:34:53.023Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.5 15.0)A
2025-11-05T22:38:07.503Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-05T22:41:57.031Z:USER:taskMaster.c:6684:Socket #1: L1N=236.8V L2N=236.8V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T22:44:52.960Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.0 14.5 15.0)A
2025-11-05T22:45:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T22:53:07.960Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-05T22:54:52.898Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 14.8 15.0)A
2025-11-05T22:56:56.937Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=233.7V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T23:00:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T23:04:52.835Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 14.9 15.0)A
2025-11-05T23:08:08.363Z:USER:taskMaster.c:6582:Temperature: 24.9 C
2025-11-05T23:11:56.839Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.1V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T23:14:52.773Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-05T23:15:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T23:23:08.871Z:USER:taskMaster.c:6582:Temperature: 25.0 C
2025-11-05T23:24:52.707Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-05T23:26:56.746Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=234.8V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T23:30:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T23:34:44.394Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-05T23:34:44.406Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-05T23:34:52.644Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 14.9 15.0)A
2025-11-05T23:38:09.226Z:USER:taskMaster.c:6582:Temperature: 24.9 C
2025-11-05T23:41:56.652Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=235.3V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-05T23:44:52.582Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.9 15.0 15.0)A
2025-11-05T23:45:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-05T23:53:09.628Z:USER:taskMaster.c:6582:Temperature: 24.8 C
2025-11-05T23:54:52.519Z:INFO:active_lb.c:308:SMt:(7.0 1.0 1.0)A Free:(9.0 15.0 15.0)A ALB:(8.9 15.0 15.0)A
2025-11-05T23:56:56.554Z:USER:taskMaster.c:6684:Socket #1: L1N=235.7V L2N=236.2V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T00:00:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T00:04:52.457Z:INFO:active_lb.c:308:SMt:(7.0 1.0 1.0)A Free:(9.0 15.0 15.0)A ALB:(9.0 15.0 15.0)A
2025-11-06T00:08:10.085Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-06T00:11:56.460Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=234.4V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T00:14:52.390Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(13.1 15.0 15.0)A
2025-11-06T00:15:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T00:23:10.539Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-06T00:24:52.328Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T00:26:56.367Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=234.4V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T00:30:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T00:34:52.265Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T00:38:10.996Z:USER:taskMaster.c:6582:Temperature: 24.4 C
2025-11-06T00:41:56.320Z:USER:taskMaster.c:6684:Socket #1: L1N=234.9V L2N=235.5V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T00:44:52.203Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.0 15.0 15.0)A
2025-11-06T00:45:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T00:53:11.449Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-06T00:54:52.187Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T00:56:56.277Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=235.5V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T01:00:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T01:04:52.125Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T01:08:11.855Z:USER:taskMaster.c:6582:Temperature: 24.1 C
2025-11-06T01:11:56.179Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.6V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T01:14:52.062Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T01:15:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T01:23:12.257Z:USER:taskMaster.c:6582:Temperature: 24.1 C
2025-11-06T01:24:52.000Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.0 15.0 15.0)A
2025-11-06T01:26:56.085Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=234.7V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T01:30:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T01:34:37.792Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-06T01:34:38.058Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-06T01:34:43.632Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-06T01:34:43.644Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-06T01:34:51.933Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T01:38:12.714Z:USER:taskMaster.c:6582:Temperature: 24.0 C
2025-11-06T01:41:55.992Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=235.0V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T01:44:51.871Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.0 15.0 15.0)A
2025-11-06T01:45:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T01:53:13.117Z:USER:taskMaster.c:6582:Temperature: 23.9 C
2025-11-06T01:54:51.808Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(13.5 15.0 15.0)A
2025-11-06T01:56:55.894Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=235.7V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T02:00:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T02:04:51.746Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-06T02:08:13.574Z:USER:taskMaster.c:6582:Temperature: 23.8 C
2025-11-06T02:11:55.800Z:USER:taskMaster.c:6684:Socket #1: L1N=235.3V L2N=235.9V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T02:14:51.679Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-06T02:15:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T02:23:14.027Z:USER:taskMaster.c:6582:Temperature: 23.9 C
2025-11-06T02:24:51.617Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-06T02:26:55.703Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=235.6V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T02:30:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T02:34:51.554Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-06T02:38:14.433Z:USER:taskMaster.c:6582:Temperature: 23.8 C
2025-11-06T02:41:55.609Z:USER:taskMaster.c:6684:Socket #1: L1N=235.7V L2N=235.7V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T02:44:51.492Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-06T02:45:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T02:53:14.839Z:USER:taskMaster.c:6582:Temperature: 23.6 C
2025-11-06T02:54:51.425Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-06T02:56:55.515Z:USER:taskMaster.c:6684:Socket #1: L1N=236.6V L2N=236.8V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T03:00:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T03:04:51.363Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-06T03:08:15.292Z:USER:taskMaster.c:6582:Temperature: 23.4 C
2025-11-06T03:11:55.417Z:USER:taskMaster.c:6684:Socket #1: L1N=236.0V L2N=236.1V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T03:14:51.300Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-06T03:15:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T03:23:15.699Z:USER:taskMaster.c:6582:Temperature: 23.1 C
2025-11-06T03:24:51.238Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-06T03:26:55.324Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=236.2V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T03:30:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T03:34:42.871Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-06T03:34:42.882Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-06T03:34:51.171Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-06T03:38:16.101Z:USER:taskMaster.c:6582:Temperature: 23.1 C
2025-11-06T03:41:55.226Z:USER:taskMaster.c:6684:Socket #1: L1N=235.6V L2N=235.9V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T03:44:51.109Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-06T03:45:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T03:53:16.507Z:USER:taskMaster.c:6582:Temperature: 23.1 C
2025-11-06T03:54:51.046Z:INFO:active_lb.c:308:SMt:(1.0 1.0 4.0)A Free:(15.0 15.0 12.0)A ALB:(14.8 15.0 12.0)A
2025-11-06T03:56:55.132Z:USER:taskMaster.c:6684:Socket #1: L1N=236.0V L2N=236.2V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T04:00:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T04:04:50.984Z:INFO:active_lb.c:308:SMt:(1.0 1.0 4.0)A Free:(15.0 15.0 12.0)A ALB:(15.0 15.0 12.0)A
2025-11-06T04:08:17.011Z:USER:taskMaster.c:6582:Temperature: 23.0 C
2025-11-06T04:11:55.039Z:USER:taskMaster.c:6684:Socket #1: L1N=234.3V L2N=234.5V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T04:14:50.917Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-06T04:15:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T04:23:17.414Z:USER:taskMaster.c:6582:Temperature: 22.9 C
2025-11-06T04:24:50.855Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.3)A
2025-11-06T04:26:54.941Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.3V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T04:30:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T04:34:50.792Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-06T04:38:17.820Z:USER:taskMaster.c:6582:Temperature: 22.9 C
2025-11-06T04:41:54.847Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=233.6V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T04:44:50.726Z:INFO:active_lb.c:308:SMt:(1.0 1.0 4.0)A Free:(15.0 15.0 12.0)A ALB:(15.0 15.0 12.0)A
2025-11-06T04:45:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T04:53:18.273Z:USER:taskMaster.c:6582:Temperature: 22.6 C
2025-11-06T04:54:50.664Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-06T04:56:54.750Z:USER:taskMaster.c:6684:Socket #1: L1N=235.6V L2N=236.2V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T05:00:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T05:04:50.601Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T05:08:18.730Z:USER:taskMaster.c:6582:Temperature: 22.6 C
2025-11-06T05:11:54.656Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=235.0V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T05:14:50.535Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T05:15:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T05:23:19.132Z:USER:taskMaster.c:6582:Temperature: 22.4 C
2025-11-06T05:24:50.472Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T05:26:54.558Z:USER:taskMaster.c:6684:Socket #1: L1N=234.9V L2N=234.9V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T05:30:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T05:34:36.105Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-06T05:34:36.375Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-06T05:34:42.109Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-06T05:34:42.121Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-06T05:34:50.410Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T05:38:19.539Z:USER:taskMaster.c:6582:Temperature: 22.4 C
2025-11-06T05:41:54.464Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=233.8V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T05:44:50.347Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-06T05:45:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T05:53:20.042Z:USER:taskMaster.c:6582:Temperature: 22.4 C
2025-11-06T05:54:50.281Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 14.9 15.0)A
2025-11-06T05:56:54.367Z:USER:taskMaster.c:6684:Socket #1: L1N=234.9V L2N=235.1V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T06:00:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T06:04:50.218Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T06:08:20.445Z:USER:taskMaster.c:6582:Temperature: 22.5 C
2025-11-06T06:11:54.273Z:USER:taskMaster.c:6684:Socket #1: L1N=234.3V L2N=234.6V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T06:13:54.015Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-11-06T06:14:50.156Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(13.3 15.0 15.0)A
2025-11-06T06:15:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T06:23:20.902Z:USER:taskMaster.c:6582:Temperature: 22.5 C
2025-11-06T06:23:54.050Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-11-06T06:24:50.089Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T06:26:54.179Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=233.5V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T06:30:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T06:33:53.988Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-11-06T06:34:50.027Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T06:38:21.304Z:USER:taskMaster.c:6582:Temperature: 22.5 C
2025-11-06T06:41:54.132Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=235.4V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T06:44:49.964Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(13.1 15.0 15.0)A
2025-11-06T06:45:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T06:53:21.757Z:USER:taskMaster.c:6582:Temperature: 22.6 C
2025-11-06T06:54:49.898Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T06:56:54.035Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=235.8V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T07:00:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T07:04:49.835Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T07:08:22.164Z:USER:taskMaster.c:6582:Temperature: 22.6 C
2025-11-06T07:11:53.941Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=236.0V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T07:14:49.773Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T07:15:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T07:23:22.769Z:USER:taskMaster.c:6582:Temperature: 22.6 C
2025-11-06T07:24:49.710Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.5 14.2 15.0)A
2025-11-06T07:26:53.847Z:USER:taskMaster.c:6684:Socket #1: L1N=235.1V L2N=235.6V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T07:30:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T07:34:41.343Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-06T07:34:41.355Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-06T07:34:49.695Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-06T07:38:23.074Z:USER:taskMaster.c:6582:Temperature: 22.6 C
2025-11-06T07:41:53.750Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=236.1V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T07:44:49.632Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.1 15.0 15.0)A
2025-11-06T07:45:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T07:53:23.527Z:USER:taskMaster.c:6582:Temperature: 22.6 C
2025-11-06T07:54:49.566Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(16.5 15.0 15.0)A
2025-11-06T07:56:53.656Z:USER:taskMaster.c:6684:Socket #1: L1N=237.3V L2N=237.4V L3N=236.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T08:00:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T08:04:49.503Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(16.9 15.0 15.0)A
2025-11-06T08:08:23.882Z:USER:taskMaster.c:6582:Temperature: 22.9 C
2025-11-06T08:11:53.558Z:USER:taskMaster.c:6684:Socket #1: L1N=236.8V L2N=238.0V L3N=237.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T08:14:49.441Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-06T08:15:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T08:23:24.335Z:USER:taskMaster.c:6582:Temperature: 23.0 C
2025-11-06T08:24:49.375Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.2 15.0 15.0)A
2025-11-06T08:26:53.464Z:USER:taskMaster.c:6684:Socket #1: L1N=235.4V L2N=236.4V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T08:30:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T08:34:49.312Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.6 15.0)A
2025-11-06T08:38:24.789Z:USER:taskMaster.c:6582:Temperature: 23.1 C
2025-11-06T08:41:53.367Z:USER:taskMaster.c:6684:Socket #1: L1N=235.1V L2N=236.0V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T08:44:49.250Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-06T08:45:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T08:53:25.195Z:USER:taskMaster.c:6582:Temperature: 23.1 C
2025-11-06T08:54:49.187Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-06T08:56:53.273Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=236.2V L3N=235.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T09:00:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T09:04:49.121Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T09:08:25.648Z:USER:taskMaster.c:6582:Temperature: 23.2 C
2025-11-06T09:11:53.175Z:USER:taskMaster.c:6684:Socket #1: L1N=236.6V L2N=237.1V L3N=236.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T09:14:49.058Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-06T09:15:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T09:23:26.203Z:USER:taskMaster.c:6582:Temperature: 23.5 C
2025-11-06T09:24:48.996Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(16.9 17.0 15.0)A
2025-11-06T09:26:53.082Z:USER:taskMaster.c:6684:Socket #1: L1N=237.1V L2N=238.0V L3N=236.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T09:30:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T09:34:34.433Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-06T09:34:34.703Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-06T09:34:40.582Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-06T09:34:40.593Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-06T09:34:48.929Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(15.0 17.0 15.0)A ALB:(15.1 17.0 15.0)A
2025-11-06T09:34:48.941Z:INFO:comFaults.c:482:Reset fault status
2025-11-06T09:38:26.558Z:USER:taskMaster.c:6582:Temperature: 23.9 C
2025-11-06T09:41:52.988Z:USER:taskMaster.c:6684:Socket #1: L1N=238.8V L2N=239.3V L3N=238.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T09:44:48.867Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(15.0 17.0 15.0)A ALB:(15.0 17.0 15.0)A
2025-11-06T09:45:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T09:53:26.964Z:USER:taskMaster.c:6582:Temperature: 24.1 C
2025-11-06T09:54:48.804Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-06T09:56:52.890Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=236.0V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T10:00:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T10:04:48.742Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-06T10:08:27.367Z:USER:taskMaster.c:6582:Temperature: 24.4 C
2025-11-06T10:11:52.796Z:USER:taskMaster.c:6684:Socket #1: L1N=235.4V L2N=236.7V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T10:14:48.675Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(15.0 17.0 15.0)A ALB:(15.2 17.0 15.0)A
2025-11-06T10:15:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T10:23:27.824Z:USER:taskMaster.c:6582:Temperature: 24.9 C
2025-11-06T10:24:48.613Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-06T10:26:52.699Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=233.8V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T10:30:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T10:34:48.550Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-06T10:38:28.226Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-06T10:41:52.605Z:USER:taskMaster.c:6684:Socket #1: L1N=235.3V L2N=236.7V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T10:44:48.488Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-06T10:45:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T10:53:28.632Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-06T10:54:48.425Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-06T10:56:52.511Z:USER:taskMaster.c:6684:Socket #1: L1N=236.7V L2N=236.9V L3N=236.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T11:00:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T11:04:48.359Z:INFO:active_lb.c:308:SMt:(1.0 -2.0 1.0)A Free:(15.0 18.0 15.0)A ALB:(15.0 18.0 15.0)A
2025-11-06T11:08:29.136Z:USER:taskMaster.c:6582:Temperature: 25.6 C
2025-11-06T11:11:52.417Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=236.5V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T11:14:48.296Z:INFO:active_lb.c:308:SMt:(-2.0 -3.0 1.0)A Free:(18.0 19.0 15.0)A ALB:(16.7 19.0 15.0)A
2025-11-06T11:15:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T11:23:29.542Z:USER:taskMaster.c:6582:Temperature: 25.6 C
2025-11-06T11:24:48.234Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(15.0 17.0 15.0)A ALB:(15.0 17.4 15.0)A
2025-11-06T11:26:52.320Z:USER:taskMaster.c:6684:Socket #1: L1N=237.3V L2N=238.7V L3N=239.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T11:30:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T11:34:39.820Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-06T11:34:39.832Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-06T11:34:48.171Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(18.0 18.0 15.0)A ALB:(17.6 17.9 15.0)A
2025-11-06T11:38:29.949Z:USER:taskMaster.c:6582:Temperature: 26.0 C
2025-11-06T11:41:52.226Z:USER:taskMaster.c:6684:Socket #1: L1N=236.2V L2N=237.0V L3N=238.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T11:44:48.105Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(18.0 18.0 15.0)A ALB:(18.0 18.0 15.0)A
2025-11-06T11:45:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T11:53:30.453Z:USER:taskMaster.c:6582:Temperature: 26.0 C
2025-11-06T11:54:48.042Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-06T11:56:52.132Z:USER:taskMaster.c:6684:Socket #1: L1N=236.2V L2N=236.5V L3N=237.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T12:00:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T12:04:47.980Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-06T12:08:30.855Z:USER:taskMaster.c:6582:Temperature: 26.0 C
2025-11-06T12:11:52.035Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=235.4V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T12:14:47.917Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-06T12:15:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T12:23:31.261Z:USER:taskMaster.c:6582:Temperature: 26.0 C
2025-11-06T12:24:47.855Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-06T12:26:51.941Z:USER:taskMaster.c:6684:Socket #1: L1N=236.0V L2N=236.5V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T12:30:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T12:34:47.789Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 14.8)A
2025-11-06T12:38:31.718Z:USER:taskMaster.c:6582:Temperature: 26.1 C
2025-11-06T12:41:51.847Z:USER:taskMaster.c:6684:Socket #1: L1N=236.0V L2N=235.2V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T12:44:47.726Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(16.7 15.0 15.0)A
2025-11-06T12:45:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T12:53:32.121Z:USER:taskMaster.c:6582:Temperature: 26.4 C
2025-11-06T12:54:47.664Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-06T12:56:51.750Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=236.5V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T13:00:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T13:04:47.601Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(16.9 15.0 15.0)A
2025-11-06T13:08:32.527Z:USER:taskMaster.c:6582:Temperature: 26.5 C
2025-11-06T13:11:51.656Z:USER:taskMaster.c:6684:Socket #1: L1N=237.0V L2N=236.9V L3N=236.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T13:14:47.539Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.7 15.0 15.0)A
2025-11-06T13:15:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T13:23:32.980Z:USER:taskMaster.c:6582:Temperature: 26.6 C
2025-11-06T13:24:47.472Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-06T13:26:51.562Z:USER:taskMaster.c:6684:Socket #1: L1N=235.8V L2N=236.5V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T13:30:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T13:34:32.773Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-06T13:34:33.042Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-06T13:34:39.062Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-06T13:34:39.070Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-06T13:34:47.410Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-06T13:38:33.386Z:USER:taskMaster.c:6582:Temperature: 26.9 C
2025-11-06T13:41:51.464Z:USER:taskMaster.c:6684:Socket #1: L1N=237.9V L2N=238.8V L3N=237.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T13:44:47.347Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 2.0)A Free:(17.0 17.0 14.0)A ALB:(17.0 17.0 14.6)A
2025-11-06T13:45:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T13:53:33.792Z:USER:taskMaster.c:6582:Temperature: 27.0 C
2025-11-06T13:54:47.285Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(15.0 17.0 15.0)A ALB:(15.1 17.0 15.0)A
2025-11-06T13:56:51.371Z:USER:taskMaster.c:6684:Socket #1: L1N=237.0V L2N=237.7V L3N=237.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T14:00:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T14:04:47.222Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-06T14:08:34.246Z:USER:taskMaster.c:6582:Temperature: 26.9 C
2025-11-06T14:11:51.277Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=236.6V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T14:14:47.156Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-06T14:15:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T14:23:34.652Z:USER:taskMaster.c:6582:Temperature: 26.9 C
2025-11-06T14:24:47.093Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.6 15.0 15.0)A
2025-11-06T14:26:51.183Z:USER:taskMaster.c:6684:Socket #1: L1N=236.6V L2N=237.2V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T14:30:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T14:34:47.031Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(15.0 17.0 15.0)A ALB:(15.3 17.0 15.0)A
2025-11-06T14:38:35.109Z:USER:taskMaster.c:6582:Temperature: 26.8 C
2025-11-06T14:41:51.085Z:USER:taskMaster.c:6684:Socket #1: L1N=237.0V L2N=237.9V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T14:44:46.968Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(15.0 17.0 15.0)A ALB:(15.0 17.0 15.0)A
2025-11-06T14:45:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T14:53:35.511Z:USER:taskMaster.c:6582:Temperature: 26.5 C
2025-11-06T14:54:46.906Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T14:56:50.992Z:USER:taskMaster.c:6684:Socket #1: L1N=235.4V L2N=236.7V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T15:00:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T15:04:46.843Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T15:08:35.968Z:USER:taskMaster.c:6582:Temperature: 26.2 C
2025-11-06T15:11:50.898Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=236.6V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T15:14:46.777Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.1 15.0 15.0)A
2025-11-06T15:15:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T15:23:36.375Z:USER:taskMaster.c:6582:Temperature: 26.2 C
2025-11-06T15:24:46.714Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.5 15.0 15.0)A
2025-11-06T15:26:50.800Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=235.3V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T15:30:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T15:34:38.300Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-06T15:34:38.312Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-06T15:34:46.652Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.4 15.0 15.0)A
2025-11-06T15:38:36.781Z:USER:taskMaster.c:6582:Temperature: 26.2 C
2025-11-06T15:41:50.707Z:USER:taskMaster.c:6684:Socket #1: L1N=234.3V L2N=236.0V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T15:44:46.589Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.2 15.0 15.0)A
2025-11-06T15:45:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T15:53:37.234Z:USER:taskMaster.c:6582:Temperature: 26.0 C
2025-11-06T15:54:46.527Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.3 15.0)A
2025-11-06T15:56:50.613Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=234.0V L3N=231.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T16:00:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T16:04:46.460Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T16:08:37.636Z:USER:taskMaster.c:6582:Temperature: 26.0 C
2025-11-06T16:11:21.125Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-11-06T16:11:50.519Z:USER:taskMaster.c:6684:Socket #1: L1N=230.4V L2N=231.5V L3N=230.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T16:14:46.398Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(11.0 15.0 14.4)A
2025-11-06T16:15:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T16:21:21.062Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-11-06T16:23:38.042Z:USER:taskMaster.c:6582:Temperature: 25.9 C
2025-11-06T16:24:46.335Z:INFO:active_lb.c:308:SMt:(5.0 1.0 1.0)A Free:(11.0 15.0 15.0)A ALB:(12.0 15.0 14.5)A
2025-11-06T16:26:50.421Z:USER:taskMaster.c:6684:Socket #1: L1N=227.2V L2N=230.7V L3N=229.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T16:30:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T16:31:21.097Z:INFO:taskLeds.c:338:Brightness set to 8%
2025-11-06T16:34:46.273Z:INFO:active_lb.c:308:SMt:(5.0 3.0 1.0)A Free:(11.0 13.0 15.0)A ALB:(10.8 13.1 15.0)A
2025-11-06T16:38:38.449Z:USER:taskMaster.c:6582:Temperature: 25.6 C
2025-11-06T16:41:50.328Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=232.9V L3N=230.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T16:44:46.210Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.0 14.0 15.0)A
2025-11-06T16:45:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T16:53:38.855Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-06T16:54:46.144Z:INFO:active_lb.c:308:SMt:(3.0 2.0 1.0)A Free:(13.0 14.0 15.0)A ALB:(13.3 13.8 15.0)A
2025-11-06T16:56:50.234Z:USER:taskMaster.c:6684:Socket #1: L1N=231.6V L2N=231.3V L3N=231.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T17:00:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T17:04:46.082Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(13.8 13.5 15.0)A
2025-11-06T17:08:39.308Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-06T17:11:50.136Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=233.8V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T17:14:46.019Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.0 15.0 15.0)A
2025-11-06T17:15:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T17:23:39.761Z:USER:taskMaster.c:6582:Temperature: 25.0 C
2025-11-06T17:24:45.957Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.0 15.0 15.0)A
2025-11-06T17:26:50.042Z:USER:taskMaster.c:6684:Socket #1: L1N=232.0V L2N=231.3V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T17:30:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T17:34:32.097Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-06T17:34:32.371Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-06T17:34:37.542Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-06T17:34:37.554Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-06T17:34:45.894Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.0 14.0 15.0)A
2025-11-06T17:38:40.167Z:USER:taskMaster.c:6582:Temperature: 24.9 C
2025-11-06T17:41:49.949Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=233.5V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T17:44:45.828Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.0 14.0 15.0)A
2025-11-06T17:45:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T17:53:40.671Z:USER:taskMaster.c:6582:Temperature: 24.8 C
2025-11-06T17:54:45.765Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.0 14.0 15.0)A
2025-11-06T17:56:49.855Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=234.2V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T18:00:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T18:04:45.703Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.0 14.0 15.0)A
2025-11-06T18:08:41.027Z:USER:taskMaster.c:6582:Temperature: 24.9 C
2025-11-06T18:11:49.757Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=231.5V L3N=231.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T18:14:45.640Z:INFO:active_lb.c:308:SMt:(3.0 3.0 1.0)A Free:(13.0 13.0 15.0)A ALB:(13.4 13.6 15.0)A
2025-11-06T18:15:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T18:23:41.535Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-06T18:24:45.578Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 13.8 15.0)A
2025-11-06T18:26:49.664Z:USER:taskMaster.c:6684:Socket #1: L1N=233.2V L2N=232.7V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T18:30:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T18:34:45.511Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-06T18:38:41.937Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-06T18:41:49.570Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=233.1V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T18:44:45.449Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(14.6 13.9 15.0)A
2025-11-06T18:45:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T18:53:42.343Z:USER:taskMaster.c:6582:Temperature: 24.9 C
2025-11-06T18:54:45.386Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-06T18:56:49.472Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.0V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T19:00:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T19:04:45.375Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.6 15.0)A
2025-11-06T19:08:42.750Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-06T19:11:49.378Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=235.1V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T19:14:45.308Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(14.0 13.0 15.0)A ALB:(14.0 13.0 15.0)A
2025-11-06T19:15:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T19:23:43.152Z:USER:taskMaster.c:6582:Temperature: 24.5 C
2025-11-06T19:24:45.246Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 13.9 15.0)A
2025-11-06T19:26:49.285Z:USER:taskMaster.c:6684:Socket #1: L1N=230.5V L2N=231.4V L3N=230.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T19:30:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T19:34:36.781Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-06T19:34:36.792Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-06T19:34:45.183Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 14.9 15.0)A
2025-11-06T19:38:43.609Z:USER:taskMaster.c:6582:Temperature: 24.4 C
2025-11-06T19:41:49.187Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=235.1V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T19:44:45.121Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.0 14.4 13.5)A
2025-11-06T19:45:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T19:53:44.011Z:USER:taskMaster.c:6582:Temperature: 24.5 C
2025-11-06T19:54:45.054Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 13.4 15.0)A
2025-11-06T19:56:49.093Z:USER:taskMaster.c:6684:Socket #1: L1N=236.4V L2N=236.1V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T20:00:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T20:04:44.992Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.4 13.8 15.0)A
2025-11-06T20:08:44.417Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-06T20:11:49.000Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=233.9V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T20:14:44.929Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 14.8 15.0)A
2025-11-06T20:15:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T20:23:44.875Z:USER:taskMaster.c:6582:Temperature: 24.1 C
2025-11-06T20:24:44.867Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.6 15.0)A
2025-11-06T20:26:48.902Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.8V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T20:30:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T20:34:44.804Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.2 13.9 15.0)A
2025-11-06T20:38:45.277Z:USER:taskMaster.c:6582:Temperature: 24.0 C
2025-11-06T20:41:48.808Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=233.3V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T20:44:44.738Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 13.9 15.0)A
2025-11-06T20:45:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T20:53:45.734Z:USER:taskMaster.c:6582:Temperature: 24.0 C
2025-11-06T20:54:44.675Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-11-06T20:56:48.714Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=234.5V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T21:00:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T21:04:44.613Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(14.0 13.0 15.0)A ALB:(13.9 13.0 15.0)A
2025-11-06T21:08:46.136Z:USER:taskMaster.c:6582:Temperature: 23.9 C
2025-11-06T21:11:48.617Z:USER:taskMaster.c:6684:Socket #1: L1N=236.0V L2N=235.8V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T21:14:44.550Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-06T21:15:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T21:23:46.593Z:USER:taskMaster.c:6582:Temperature: 23.8 C
2025-11-06T21:24:44.484Z:INFO:active_lb.c:308:SMt:(2.0 3.0 1.0)A Free:(14.0 13.0 15.0)A ALB:(14.5 13.0 15.0)A
2025-11-06T21:26:48.523Z:USER:taskMaster.c:6684:Socket #1: L1N=236.8V L2N=236.2V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T21:30:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T21:34:30.433Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-06T21:34:30.757Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-06T21:34:36.023Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-06T21:34:36.031Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-06T21:34:44.421Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-06T21:34:44.433Z:INFO:comFaults.c:482:Reset fault status
2025-11-06T21:38:46.996Z:USER:taskMaster.c:6582:Temperature: 23.5 C
2025-11-06T21:41:48.425Z:USER:taskMaster.c:6684:Socket #1: L1N=233.2V L2N=232.8V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T21:44:44.359Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(14.9 14.0 15.0)A
2025-11-06T21:45:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T21:53:47.453Z:USER:taskMaster.c:6582:Temperature: 23.6 C
2025-11-06T21:54:44.296Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-06T21:56:48.332Z:USER:taskMaster.c:6684:Socket #1: L1N=234.9V L2N=234.4V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T22:00:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T22:04:44.230Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-06T22:08:48.007Z:USER:taskMaster.c:6582:Temperature: 23.8 C
2025-11-06T22:11:48.238Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=232.8V L3N=232.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T22:14:44.167Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.1 15.0)A
2025-11-06T22:15:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T22:23:48.609Z:USER:taskMaster.c:6582:Temperature: 24.0 C
2025-11-06T22:24:44.105Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.9 15.0 15.0)A
2025-11-06T22:26:48.140Z:USER:taskMaster.c:6684:Socket #1: L1N=231.8V L2N=232.2V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T22:30:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T22:34:44.042Z:INFO:active_lb.c:308:SMt:(2.0 6.0 1.0)A Free:(14.0 10.0 15.0)A ALB:(14.0 10.0 15.0)A
2025-11-06T22:38:48.667Z:USER:taskMaster.c:6582:Temperature: 24.0 C
2025-11-06T22:41:48.046Z:USER:taskMaster.c:6684:Socket #1: L1N=235.8V L2N=235.3V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T22:44:43.976Z:INFO:active_lb.c:308:SMt:(2.0 1.0 1.0)A Free:(14.0 15.0 15.0)A ALB:(14.1 14.9 15.0)A
2025-11-06T22:45:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T22:53:49.171Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-06T22:54:43.914Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T22:56:47.953Z:USER:taskMaster.c:6684:Socket #1: L1N=236.4V L2N=236.8V L3N=236.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T23:00:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T23:04:43.851Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T23:08:49.574Z:USER:taskMaster.c:6582:Temperature: 24.4 C
2025-11-06T23:11:47.855Z:USER:taskMaster.c:6684:Socket #1: L1N=236.9V L2N=236.9V L3N=237.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T23:14:43.789Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T23:15:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T23:23:49.980Z:USER:taskMaster.c:6582:Temperature: 24.5 C
2025-11-06T23:24:43.722Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T23:26:47.761Z:USER:taskMaster.c:6684:Socket #1: L1N=236.8V L2N=237.1V L3N=236.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T23:30:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T23:34:35.261Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-06T23:34:35.269Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-06T23:34:43.660Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T23:38:50.433Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-06T23:41:47.667Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.6V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-06T23:44:43.597Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T23:45:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-06T23:53:50.839Z:USER:taskMaster.c:6582:Temperature: 24.1 C
2025-11-06T23:54:43.535Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-06T23:56:47.570Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=234.4V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T00:00:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T00:04:43.468Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-07T00:08:51.246Z:USER:taskMaster.c:6582:Temperature: 23.9 C
2025-11-07T00:11:47.476Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=234.7V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T00:14:43.406Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-07T00:15:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T00:23:51.699Z:USER:taskMaster.c:6582:Temperature: 23.9 C
2025-11-07T00:24:43.343Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 14.5 15.0)A
2025-11-07T00:26:47.378Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=235.4V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T00:30:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T00:34:43.281Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 9.8 15.0)A
2025-11-07T00:38:52.105Z:USER:taskMaster.c:6582:Temperature: 23.8 C
2025-11-07T00:41:47.285Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=234.7V L3N=235.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T00:44:43.214Z:INFO:active_lb.c:308:SMt:(1.0 11.0 1.0)A Free:(15.0 5.0 15.0)A ALB:(15.0 5.7 15.0)A
2025-11-07T00:45:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T00:53:52.609Z:USER:taskMaster.c:6582:Temperature: 23.6 C
2025-11-07T00:54:43.152Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 9.8 15.0)A
2025-11-07T00:56:47.191Z:USER:taskMaster.c:6684:Socket #1: L1N=235.6V L2N=236.1V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T01:00:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T01:04:43.089Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 13.8 15.0)A
2025-11-07T01:08:53.414Z:USER:taskMaster.c:6582:Temperature: 23.6 C
2025-11-07T01:11:47.093Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=235.2V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T01:14:43.027Z:INFO:active_lb.c:308:SMt:(1.0 11.0 1.0)A Free:(15.0 5.0 15.0)A ALB:(14.8 8.8 15.0)A
2025-11-07T01:15:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T01:23:53.417Z:USER:taskMaster.c:6582:Temperature: 23.5 C
2025-11-07T01:24:42.964Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-07T01:26:47.000Z:USER:taskMaster.c:6684:Socket #1: L1N=235.7V L2N=236.6V L3N=236.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T01:30:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T01:34:28.761Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-07T01:34:29.031Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-07T01:34:34.500Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-07T01:34:34.511Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-07T01:34:42.898Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.2 15.0)A
2025-11-07T01:38:54.074Z:USER:taskMaster.c:6582:Temperature: 23.2 C
2025-11-07T01:41:46.906Z:USER:taskMaster.c:6684:Socket #1: L1N=236.7V L2N=236.4V L3N=237.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T01:44:42.835Z:INFO:active_lb.c:308:SMt:(1.0 6.0 1.0)A Free:(15.0 10.0 15.0)A ALB:(15.0 10.0 15.0)A
2025-11-07T01:45:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T01:53:54.277Z:USER:taskMaster.c:6582:Temperature: 23.2 C
2025-11-07T01:54:42.773Z:INFO:active_lb.c:308:SMt:(1.0 6.0 1.0)A Free:(15.0 10.0 15.0)A ALB:(15.0 10.0 15.0)A
2025-11-07T01:56:46.808Z:USER:taskMaster.c:6684:Socket #1: L1N=235.1V L2N=235.0V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T02:00:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T02:04:42.707Z:INFO:active_lb.c:308:SMt:(1.0 6.0 5.0)A Free:(15.0 10.0 11.0)A ALB:(15.0 10.0 11.0)A
2025-11-07T02:08:54.781Z:USER:taskMaster.c:6582:Temperature: 23.2 C
2025-11-07T02:11:46.714Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=233.9V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T02:14:42.644Z:INFO:active_lb.c:308:SMt:(1.0 6.0 5.0)A Free:(15.0 10.0 11.0)A ALB:(15.0 9.9 11.0)A
2025-11-07T02:15:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T02:23:55.187Z:USER:taskMaster.c:6582:Temperature: 23.0 C
2025-11-07T02:24:42.582Z:INFO:active_lb.c:308:SMt:(1.0 7.0 5.0)A Free:(15.0 9.0 11.0)A ALB:(15.0 8.8 11.0)A
2025-11-07T02:26:46.617Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=234.3V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T02:30:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T02:34:42.519Z:INFO:active_lb.c:308:SMt:(1.0 6.0 5.0)A Free:(15.0 10.0 11.0)A ALB:(15.0 10.0 11.0)A
2025-11-07T02:38:55.589Z:USER:taskMaster.c:6582:Temperature: 23.0 C
2025-11-07T02:41:46.523Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=234.7V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T02:44:42.453Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-07T02:45:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T02:53:56.046Z:USER:taskMaster.c:6582:Temperature: 23.0 C
2025-11-07T02:54:42.390Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-07T02:56:46.429Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=235.7V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T03:00:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T03:04:42.328Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-07T03:08:56.449Z:USER:taskMaster.c:6582:Temperature: 22.9 C
2025-11-07T03:11:46.332Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.3V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T03:14:42.265Z:INFO:active_lb.c:308:SMt:(1.0 2.0 5.0)A Free:(15.0 14.0 11.0)A ALB:(15.0 14.5 11.0)A
2025-11-07T03:15:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T03:23:56.906Z:USER:taskMaster.c:6582:Temperature: 22.8 C
2025-11-07T03:24:42.199Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-07T03:26:46.238Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.7V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T03:30:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T03:34:33.738Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-07T03:34:33.746Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-07T03:34:42.136Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-07T03:38:57.308Z:USER:taskMaster.c:6582:Temperature: 22.8 C
2025-11-07T03:41:46.140Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.0V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T03:44:42.074Z:INFO:active_lb.c:308:SMt:(1.0 1.0 4.0)A Free:(15.0 15.0 12.0)A ALB:(15.0 15.0 12.0)A
2025-11-07T03:45:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T03:53:57.765Z:USER:taskMaster.c:6582:Temperature: 22.6 C
2025-11-07T03:54:42.007Z:INFO:active_lb.c:308:SMt:(1.0 1.0 4.0)A Free:(15.0 15.0 12.0)A ALB:(15.0 15.0 12.0)A
2025-11-07T03:56:46.046Z:USER:taskMaster.c:6684:Socket #1: L1N=233.3V L2N=233.6V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T04:00:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T04:04:41.945Z:INFO:active_lb.c:308:SMt:(1.0 1.0 4.0)A Free:(15.0 15.0 12.0)A ALB:(15.0 15.0 12.0)A
2025-11-07T04:08:58.167Z:USER:taskMaster.c:6582:Temperature: 22.6 C
2025-11-07T04:11:45.949Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=236.6V L3N=236.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T04:14:41.882Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-07T04:15:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T04:23:58.625Z:USER:taskMaster.c:6582:Temperature: 22.6 C
2025-11-07T04:24:41.820Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-07T04:26:45.855Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=235.1V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T04:30:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T04:34:41.753Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-07T04:38:59.425Z:USER:taskMaster.c:6582:Temperature: 22.6 C
2025-11-07T04:41:45.761Z:USER:taskMaster.c:6684:Socket #1: L1N=236.0V L2N=236.2V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T04:44:41.691Z:INFO:active_lb.c:308:SMt:(1.0 1.0 4.0)A Free:(15.0 15.0 12.0)A ALB:(15.0 15.0 12.0)A
2025-11-07T04:45:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T04:53:59.484Z:USER:taskMaster.c:6582:Temperature: 22.4 C
2025-11-07T04:54:41.628Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-07T04:56:45.664Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=235.1V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T05:00:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T05:04:41.562Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-07T05:08:59.988Z:USER:taskMaster.c:6582:Temperature: 22.5 C
2025-11-07T05:11:45.570Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=235.5V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T05:14:41.500Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-07T05:15:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T05:24:00.390Z:USER:taskMaster.c:6582:Temperature: 22.5 C
2025-11-07T05:24:41.437Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-07T05:26:45.472Z:USER:taskMaster.c:6684:Socket #1: L1N=236.5V L2N=237.4V L3N=237.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T05:30:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T05:34:27.085Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-07T05:34:27.355Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-07T05:34:32.972Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-07T05:34:32.984Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-07T05:34:41.375Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(13.8 15.0 15.0)A
2025-11-07T05:39:00.847Z:USER:taskMaster.c:6582:Temperature: 22.5 C
2025-11-07T05:41:45.378Z:USER:taskMaster.c:6684:Socket #1: L1N=236.5V L2N=237.1V L3N=236.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T05:44:41.308Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-07T05:45:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T05:54:01.351Z:USER:taskMaster.c:6582:Temperature: 22.4 C
2025-11-07T05:54:41.246Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(15.0 15.0 14.0)A
2025-11-07T05:56:45.281Z:USER:taskMaster.c:6684:Socket #1: L1N=235.4V L2N=236.3V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T06:00:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T06:04:41.183Z:INFO:active_lb.c:308:SMt:(6.0 1.0 1.0)A Free:(10.0 15.0 15.0)A ALB:(10.4 15.0 15.0)A
2025-11-07T06:09:01.253Z:USER:taskMaster.c:6582:Temperature: 22.2 C
2025-11-07T06:11:45.187Z:USER:taskMaster.c:6684:Socket #1: L1N=235.1V L2N=236.8V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T06:14:41.117Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-07T06:15:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T06:15:43.367Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-11-07T06:24:02.109Z:USER:taskMaster.c:6582:Temperature: 22.4 C
2025-11-07T06:24:41.054Z:INFO:active_lb.c:308:SMt:(2.0 6.0 1.0)A Free:(14.0 10.0 15.0)A ALB:(14.0 9.5 15.0)A
2025-11-07T06:25:43.402Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-11-07T06:26:45.089Z:USER:taskMaster.c:6684:Socket #1: L1N=233.4V L2N=233.9V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T06:30:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T06:34:40.992Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-07T06:35:43.437Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-11-07T06:39:02.562Z:USER:taskMaster.c:6582:Temperature: 22.4 C
2025-11-07T06:41:44.996Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=235.2V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T06:44:40.925Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.0 15.0 15.0)A
2025-11-07T06:45:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T06:54:03.417Z:USER:taskMaster.c:6582:Temperature: 22.5 C
2025-11-07T06:54:40.863Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.5 15.0 15.0)A
2025-11-07T06:56:44.898Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=236.0V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T07:00:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T07:04:40.800Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-07T07:09:03.421Z:USER:taskMaster.c:6582:Temperature: 22.6 C
2025-11-07T07:11:44.804Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=235.6V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T07:14:40.734Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.1 15.0)A
2025-11-07T07:15:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T07:24:03.875Z:USER:taskMaster.c:6582:Temperature: 22.6 C
2025-11-07T07:24:40.671Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-07T07:26:44.710Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=235.5V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T07:30:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T07:34:32.207Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-07T07:34:32.218Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-07T07:34:40.609Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-07T07:39:04.281Z:USER:taskMaster.c:6582:Temperature: 22.5 C
2025-11-07T07:41:44.613Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=235.2V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T07:44:40.542Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(12.0 14.0 15.0)A
2025-11-07T07:45:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T07:54:04.734Z:USER:taskMaster.c:6582:Temperature: 22.8 C
2025-11-07T07:54:40.480Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.5 14.0 15.0)A
2025-11-07T07:56:44.519Z:USER:taskMaster.c:6684:Socket #1: L1N=235.3V L2N=235.9V L3N=235.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T08:00:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T08:04:40.417Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 12.0 15.0)A
2025-11-07T08:09:05.191Z:USER:taskMaster.c:6582:Temperature: 22.9 C
2025-11-07T08:11:44.421Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.0V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T08:14:40.355Z:INFO:active_lb.c:308:SMt:(-1.0 3.0 1.0)A Free:(17.0 13.0 15.0)A ALB:(16.8 13.0 15.0)A
2025-11-07T08:15:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T08:24:05.644Z:USER:taskMaster.c:6582:Temperature: 23.0 C
2025-11-07T08:24:40.289Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-07T08:26:44.328Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=235.5V L3N=235.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T08:30:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T08:34:40.226Z:INFO:active_lb.c:308:SMt:(-1.0 4.0 1.0)A Free:(17.0 12.0 15.0)A ALB:(14.8 12.9 15.0)A
2025-11-07T08:39:06.046Z:USER:taskMaster.c:6582:Temperature: 23.0 C
2025-11-07T08:41:44.281Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=235.0V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T08:44:40.164Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.1 12.0 15.0)A
2025-11-07T08:45:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T08:54:06.453Z:USER:taskMaster.c:6582:Temperature: 23.2 C
2025-11-07T08:54:40.097Z:INFO:active_lb.c:308:SMt:(-1.0 4.0 1.0)A Free:(17.0 12.0 15.0)A ALB:(17.0 12.0 15.0)A
2025-11-07T08:56:44.187Z:USER:taskMaster.c:6684:Socket #1: L1N=236.4V L2N=236.6V L3N=237.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T09:00:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T09:04:40.035Z:INFO:active_lb.c:308:SMt:(-1.0 3.0 1.0)A Free:(17.0 13.0 15.0)A ALB:(17.0 13.0 15.0)A
2025-11-07T09:09:06.957Z:USER:taskMaster.c:6582:Temperature: 23.2 C
2025-11-07T09:11:44.089Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=233.3V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T09:14:39.972Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.3 14.8 15.0)A
2025-11-07T09:15:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T09:24:07.410Z:USER:taskMaster.c:6582:Temperature: 23.5 C
2025-11-07T09:24:39.910Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 1.0)A Free:(17.0 14.0 15.0)A ALB:(17.0 14.2 15.0)A
2025-11-07T09:26:43.996Z:USER:taskMaster.c:6684:Socket #1: L1N=237.2V L2N=237.3V L3N=237.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T09:30:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T09:34:26.402Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-07T09:34:26.671Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-07T09:34:31.445Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-07T09:34:31.457Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-07T09:34:39.843Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 1.0)A Free:(17.0 14.0 15.0)A ALB:(17.0 14.0 15.0)A
2025-11-07T09:34:39.855Z:INFO:comFaults.c:482:Reset fault status
2025-11-07T09:39:07.816Z:USER:taskMaster.c:6582:Temperature: 23.9 C
2025-11-07T09:41:43.898Z:USER:taskMaster.c:6684:Socket #1: L1N=235.8V L2N=236.6V L3N=236.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T09:44:39.781Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 1.0)A Free:(17.0 14.0 15.0)A ALB:(16.9 14.4 15.0)A
2025-11-07T09:45:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T09:54:08.222Z:USER:taskMaster.c:6582:Temperature: 24.1 C
2025-11-07T09:54:39.718Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 1.0)A Free:(17.0 14.0 15.0)A ALB:(16.3 17.5 15.0)A
2025-11-07T09:56:43.804Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=235.6V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T10:00:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T10:04:39.656Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 1.0)A Free:(17.0 18.0 15.0)A ALB:(16.9 8.3 15.0)A
2025-11-07T10:09:08.625Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-07T10:11:43.710Z:USER:taskMaster.c:6684:Socket #1: L1N=234.9V L2N=235.1V L3N=236.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T10:14:39.589Z:INFO:active_lb.c:308:SMt:(1.0 8.0 1.0)A Free:(15.0 8.0 15.0)A ALB:(15.8 9.1 15.0)A
2025-11-07T10:15:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T10:24:09.082Z:USER:taskMaster.c:6582:Temperature: 24.5 C
2025-11-07T10:24:39.527Z:INFO:active_lb.c:308:SMt:(-1.0 6.0 1.0)A Free:(17.0 10.0 15.0)A ALB:(17.0 17.7 15.0)A
2025-11-07T10:26:43.613Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.5V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T10:30:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T10:34:39.464Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 1.0)A Free:(17.0 18.0 15.0)A ALB:(17.0 16.0 15.0)A
2025-11-07T10:39:09.484Z:USER:taskMaster.c:6582:Temperature: 24.8 C
2025-11-07T10:41:43.519Z:USER:taskMaster.c:6684:Socket #1: L1N=236.6V L2N=237.3V L3N=237.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T10:44:39.402Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.6 15.0)A
2025-11-07T10:45:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T10:54:09.890Z:USER:taskMaster.c:6582:Temperature: 25.0 C
2025-11-07T10:54:39.335Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.2 15.0)A
2025-11-07T10:56:43.425Z:USER:taskMaster.c:6684:Socket #1: L1N=236.6V L2N=237.0V L3N=237.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T11:00:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T11:04:39.273Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-07T11:09:10.296Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-07T11:11:43.328Z:USER:taskMaster.c:6684:Socket #1: L1N=237.5V L2N=238.3V L3N=237.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T11:14:39.210Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 1.0)A Free:(17.0 18.0 15.0)A ALB:(17.1 18.0 15.0)A
2025-11-07T11:15:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T11:24:10.449Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-07T11:24:39.148Z:INFO:active_lb.c:308:SMt:(-2.0 -1.0 1.0)A Free:(18.0 17.0 15.0)A ALB:(18.0 17.0 15.0)A
2025-11-07T11:26:43.234Z:USER:taskMaster.c:6684:Socket #1: L1N=237.8V L2N=238.8V L3N=238.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T11:30:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T11:34:30.683Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-07T11:34:30.695Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-07T11:34:39.085Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(18.0 18.0 15.0)A ALB:(17.8 18.0 15.0)A
2025-11-07T11:39:11.207Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-07T11:41:43.140Z:USER:taskMaster.c:6684:Socket #1: L1N=237.8V L2N=238.6V L3N=237.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T11:44:39.019Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(18.0 18.0 15.0)A ALB:(18.0 18.0 15.0)A
2025-11-07T11:45:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T11:54:11.660Z:USER:taskMaster.c:6582:Temperature: 25.9 C
2025-11-07T11:54:38.957Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 1.0)A Free:(17.0 18.0 15.0)A ALB:(17.1 18.0 15.0)A
2025-11-07T11:56:43.042Z:USER:taskMaster.c:6684:Socket #1: L1N=237.6V L2N=238.0V L3N=237.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T12:00:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T12:04:38.894Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(18.0 18.0 15.0)A ALB:(17.1 18.0 15.0)A
2025-11-07T12:09:12.316Z:USER:taskMaster.c:6582:Temperature: 25.9 C
2025-11-07T12:11:42.949Z:USER:taskMaster.c:6684:Socket #1: L1N=237.2V L2N=238.1V L3N=237.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T12:14:38.832Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(18.0 18.0 15.0)A ALB:(18.0 17.8 15.0)A
2025-11-07T12:15:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T12:24:12.519Z:USER:taskMaster.c:6582:Temperature: 26.2 C
2025-11-07T12:24:38.765Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(18.0 18.0 15.0)A ALB:(18.0 18.0 15.0)A
2025-11-07T12:26:42.855Z:USER:taskMaster.c:6684:Socket #1: L1N=236.7V L2N=237.0V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T12:30:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T12:34:38.703Z:INFO:active_lb.c:308:SMt:(-1.0 2.0 1.0)A Free:(17.0 14.0 15.0)A ALB:(17.4 14.0 15.0)A
2025-11-07T12:39:12.925Z:USER:taskMaster.c:6582:Temperature: 26.4 C
2025-11-07T12:41:42.757Z:USER:taskMaster.c:6684:Socket #1: L1N=236.6V L2N=237.6V L3N=237.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T12:44:38.640Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(18.0 18.0 15.0)A ALB:(17.9 18.0 15.0)A
2025-11-07T12:45:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T12:54:13.378Z:USER:taskMaster.c:6582:Temperature: 26.6 C
2025-11-07T12:54:38.578Z:INFO:active_lb.c:308:SMt:(-2.0 -1.0 1.0)A Free:(18.0 17.0 15.0)A ALB:(17.6 17.0 15.0)A
2025-11-07T12:56:42.664Z:USER:taskMaster.c:6684:Socket #1: L1N=236.7V L2N=237.6V L3N=236.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T13:00:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T13:04:38.515Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-07T13:09:13.785Z:USER:taskMaster.c:6582:Temperature: 26.8 C
2025-11-07T13:11:42.570Z:USER:taskMaster.c:6684:Socket #1: L1N=238.4V L2N=238.6V L3N=238.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T13:14:38.449Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(15.0 17.0 15.0)A ALB:(15.4 17.0 15.0)A
2025-11-07T13:15:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T13:24:14.242Z:USER:taskMaster.c:6582:Temperature: 26.9 C
2025-11-07T13:24:38.386Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(16.6 17.0 15.0)A
2025-11-07T13:26:42.476Z:USER:taskMaster.c:6684:Socket #1: L1N=237.2V L2N=238.3V L3N=238.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T13:30:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T13:34:24.746Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-07T13:34:25.015Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-07T13:34:29.925Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-07T13:34:29.933Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-07T13:34:38.324Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-07T13:39:14.695Z:USER:taskMaster.c:6582:Temperature: 26.9 C
2025-11-07T13:41:42.378Z:USER:taskMaster.c:6684:Socket #1: L1N=237.0V L2N=237.5V L3N=236.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T13:44:38.261Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-07T13:45:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T13:54:15.152Z:USER:taskMaster.c:6582:Temperature: 26.9 C
2025-11-07T13:54:38.199Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-07T13:56:42.285Z:USER:taskMaster.c:6684:Socket #1: L1N=236.0V L2N=236.2V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T14:00:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T14:04:38.136Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-07T14:09:15.554Z:USER:taskMaster.c:6582:Temperature: 26.9 C
2025-11-07T14:11:42.191Z:USER:taskMaster.c:6684:Socket #1: L1N=235.6V L2N=235.8V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T14:14:38.070Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(15.0 17.0 15.0)A ALB:(15.2 17.0 15.0)A
2025-11-07T14:15:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T14:24:16.011Z:USER:taskMaster.c:6582:Temperature: 27.1 C
2025-11-07T14:24:38.007Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-07T14:26:42.093Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=234.6V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T14:30:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T14:32:15.824Z:INFO:taskMain.c:5996:Socket #1: Active current 0.0->15.0 due to current limit: Active-LoadBalancing
2025-11-07T14:32:15.859Z:INFO:taskMaster.c:4957:Socket #1: state main : CABLE_CONNECTED
2025-11-07T14:32:15.871Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_A
2025-11-07T14:32:15.878Z:INFO:taskMaster.c:4979:Socket #1: state led : CABLE_CONNECTED
2025-11-07T14:32:15.894Z:INFO:taskMain.c:6494:Socket #1: CPhigh 12.1 V
2025-11-07T14:32:15.902Z:INFO:taskMain.c:6499:Socket #1: CPlow 12.2 V
2025-11-07T14:32:15.910Z:INFO:taskMain.c:6504:Socket #1: PP 699 Ohm (20 A)
2025-11-07T14:32:15.917Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.9% (14.9 A)
2025-11-07T14:32:16.906Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-07T14:32:16.914Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-07T14:32:16.921Z:INFO:taskMain.c:1419:Socket #1: main state: CABLE_CONNECTED, CP: 9.3/0.9, no tag
2025-11-07T14:32:17.910Z:INFO:taskMaster.c:4957:Socket #1: state main : EV_CONNECTED_UNAUTHORIZED
2025-11-07T14:32:17.921Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-07T14:32:18.906Z:INFO:taskMain.c:1419:Socket #1: main state: EV_CONNECTED_UNAUTHORIZED, CP: 9.3/0.9, no tag
2025-11-07T14:32:22.609Z:USER:tag.c:1623:Reader 0 Got NFC tag: 04BB29EAFD0F94
2025-11-07T14:32:22.808Z:USER:taskMaster.c:6931:Socket #1: has reliable metervalue
2025-11-07T14:32:22.816Z:INFO:taskMaster.c:1604:1 cables attached
2025-11-07T14:32:22.859Z:INFO:taskMaster.c:4979:Socket #1: state led : AUTHORISING
2025-11-07T14:32:22.871Z:USER:tag.c:584:Tag 04BB29EAFD0F94 is authorised by white list
2025-11-07T14:32:22.910Z:USER:taskMaster.c:1914:Multiple cables attached, prioritizing socket #1
2025-11-07T14:32:22.953Z:USER:board_ng9xx.c:5068:Socket #1: lock socket motor
2025-11-07T14:32:22.964Z:INFO:taskMaster.c:4957:Socket #1: state main : EV_CONNECTED_AUTHORIZED
2025-11-07T14:32:23.671Z:INFO:taskMaster.c:7497:New charging session started, metervalue=5631423.000
2025-11-07T14:32:23.687Z:INFO:db_transaction.c:16:Added TransactionStart for socket 1 at 0x000194f4 (ts: 2025-11-07 14:32:22)
2025-11-07T14:32:23.710Z:INFO:taskMaster.c:4979:Socket #1: state led : EV_CONNECTED
2025-11-07T14:32:23.718Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:32:23.785Z:INFO:taskMaster.c:6353:Socket #1: external current limit 15.9 A until 2025-11-07T23:00:00Z
2025-11-07T14:32:23.796Z:USER:taskMaster.c:6402:Socket #1: external current limit 15.9 A
2025-11-07T14:32:23.964Z:INFO:taskMain.c:1417:Socket #1: main state: EV_CONNECTED_AUTHORIZED, CP: 9.3/9.3, tag: 04BB29EAFD0F94
2025-11-07T14:32:24.054Z:INFO:taskMain.c:938:Socket #1: charging session status set active
2025-11-07T14:32:24.066Z:INFO:taskMaster.c:4957:Socket #1: state main : WAIT_FOR_START_METERVALUE
2025-11-07T14:32:24.074Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_PREPARING
2025-11-07T14:32:25.164Z:INFO:taskMain.c:1417:Socket #1: main state: WAIT_FOR_START_METERVALUE, CP: 9.3/9.3, tag: 04BB29EAFD0F
2025-11-07T14:32:25.164Z:INFO:taskMain.c:1417:94
2025-11-07T14:32:27.109Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-07T14:32:27.117Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-07T14:32:27.160Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-07T14:32:27.183Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-07T14:32:28.132Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-07T14:32:28.207Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-07T14:32:28.218Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-07T14:32:28.226Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.3V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T14:32:28.238Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T14:32:28.250Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-07T14:32:28.257Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-07T14:32:28.265Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-07T14:32:29.144Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-07T14:32:29.234Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-07T14:32:33.816Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-07T14:32:33.824Z:INFO:db_chargingprofi:26: socket 0
2025-11-07T14:32:33.832Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-07T14:32:33.839Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-07T14:32:33.847Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-07T14:32:33.859Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-07T14:32:33.867Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-07T14:32:33.875Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-07T14:32:33.886Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-07T14:32:33.894Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-07T14:32:33.902Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-07T14:32:33.910Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-07T14:32:33.917Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-07T14:32:33.925Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-07T14:32:33.933Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-07T14:32:33.941Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-07T14:32:33.949Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-07T14:32:33.960Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-07T14:32:33.968Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-07T14:32:33.976Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-07T14:32:33.984Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-07T14:32:33.992Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-07T14:32:34.000Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-07T14:32:39.464Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.9 due to current limit: ChargingProfile
2025-11-07T14:32:39.507Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-07T14:32:40.343Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-07T14:32:58.253Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=232.5V L3N=231.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T14:32:58.269Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.6A I3=15.4A P=10.8kW Idc=0.7mA
2025-11-07T14:33:23.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:33:28.218Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-07T14:33:28.253Z:USER:taskMaster.c:6684:Socket #1: L1N=231.9V L2N=232.4V L3N=231.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T14:33:28.265Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.5A I3=15.5A P=10.8kW Idc=0.7mA
2025-11-07T14:33:51.457Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.7 due to current limit: Active-LoadBalancing
2025-11-07T14:33:51.468Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->26.2)
2025-11-07T14:33:51.500Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-07T14:33:58.250Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=232.7V L3N=231.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T14:33:58.261Z:USER:taskMaster.c:6720:Socket #1: I1=15.3A I2=15.4A I3=15.3A P=10.7kW Idc=0.7mA
2025-11-07T14:34:03.453Z:INFO:taskMain.c:5996:Socket #1: Active current 15.7->15.6 due to current limit: Active-LoadBalancing
2025-11-07T14:34:03.468Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.2->25.9)
2025-11-07T14:34:15.453Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.4 due to current limit: Active-LoadBalancing
2025-11-07T14:34:15.464Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.9->25.5)
2025-11-07T14:34:23.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:34:27.453Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.1 due to current limit: Active-LoadBalancing
2025-11-07T14:34:27.464Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->25.2)
2025-11-07T14:34:28.246Z:USER:taskMaster.c:6684:Socket #1: L1N=232.0V L2N=232.8V L3N=231.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T14:34:28.257Z:USER:taskMaster.c:6720:Socket #1: I1=15.0A I2=15.0A I3=14.8A P=10.4kW Idc=0.7mA
2025-11-07T14:34:37.945Z:INFO:active_lb.c:308:SMt:(15.0 15.0 15.0)A Free:(1.0 1.0 1.0)A ALB:(16.2 15.9 15.1)A
2025-11-07T14:34:39.449Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.3 due to current limit: Active-LoadBalancing
2025-11-07T14:34:51.449Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.5 due to current limit: Active-LoadBalancing
2025-11-07T14:34:58.242Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=233.1V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T14:34:58.253Z:USER:taskMaster.c:6720:Socket #1: I1=15.0A I2=15.1A I3=15.0A P=10.5kW Idc=0.7mA
2025-11-07T14:34:58.691Z:INFO:EVCapabilities.c:24:Socket #1 EV: #phases supported: 3
2025-11-07T14:35:03.449Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.3 due to current limit: Active-LoadBalancing
2025-11-07T14:35:03.460Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.8->25.4)
2025-11-07T14:35:15.445Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-07T14:35:15.460Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-07T14:35:23.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:35:27.445Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.3 due to current limit: Active-LoadBalancing
2025-11-07T14:35:28.238Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=233.1V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T14:35:28.250Z:USER:taskMaster.c:6720:Socket #1: I1=14.6A I2=14.7A I3=14.6A P=10.2kW Idc=0.7mA
2025-11-07T14:35:39.445Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.5 due to current limit: Active-LoadBalancing
2025-11-07T14:35:51.441Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.7 due to current limit: Active-LoadBalancing
2025-11-07T14:35:58.238Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=233.0V L3N=231.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T14:35:58.250Z:USER:taskMaster.c:6720:Socket #1: I1=15.2A I2=15.3A I3=15.1A P=10.6kW Idc=0.7mA
2025-11-07T14:36:03.441Z:INFO:taskMain.c:5996:Socket #1: Active current 15.7->15.5 due to current limit: Active-LoadBalancing
2025-11-07T14:36:03.453Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.1->25.7)
2025-11-07T14:36:15.441Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.3 due to current limit: Active-LoadBalancing
2025-11-07T14:36:15.453Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->25.4)
2025-11-07T14:36:23.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:36:27.441Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-07T14:36:27.453Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-07T14:36:28.234Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=233.4V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T14:36:28.246Z:USER:taskMaster.c:6720:Socket #1: I1=14.8A I2=14.9A I3=14.8A P=10.4kW Idc=0.7mA
2025-11-07T14:36:39.437Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.3 due to current limit: Active-LoadBalancing
2025-11-07T14:36:51.437Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.5 due to current limit: Active-LoadBalancing
2025-11-07T14:36:58.230Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=232.6V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T14:36:58.242Z:USER:taskMaster.c:6720:Socket #1: I1=15.0A I2=15.1A I3=15.0A P=10.5kW Idc=0.7mA
2025-11-07T14:37:03.437Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.3 due to current limit: Active-LoadBalancing
2025-11-07T14:37:03.449Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.8->25.4)
2025-11-07T14:37:15.433Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-07T14:37:15.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-07T14:37:23.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:37:27.433Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-07T14:37:27.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-07T14:37:28.226Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=232.7V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T14:37:28.242Z:USER:taskMaster.c:6720:Socket #1: I1=14.7A I2=14.7A I3=14.5A P=10.2kW Idc=0.7mA
2025-11-07T14:37:28.253Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-07T14:37:39.433Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-07T14:37:39.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-07T14:37:51.429Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-07T14:37:51.441Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-07T14:38:03.429Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-07T14:38:15.429Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-07T14:38:23.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:38:27.425Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.4 due to current limit: Active-LoadBalancing
2025-11-07T14:38:39.425Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.6 due to current limit: Active-LoadBalancing
2025-11-07T14:38:51.425Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.4 due to current limit: Active-LoadBalancing
2025-11-07T14:38:51.437Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.0->25.7)
2025-11-07T14:39:03.421Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->9.4 due to current limit: Active-LoadBalancing
2025-11-07T14:39:03.437Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->15.7)
2025-11-07T14:39:04.113Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.7% (9.4 A)
2025-11-07T14:39:15.421Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->11.5 due to current limit: Active-LoadBalancing
2025-11-07T14:39:16.230Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.1% (11.5 A)
2025-11-07T14:39:16.816Z:USER:taskMaster.c:6582:Temperature: 28.1 C
2025-11-07T14:39:23.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:39:27.421Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->15.9 due to current limit: ChargingProfile
2025-11-07T14:39:27.464Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-07T14:39:28.351Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-07T14:40:03.417Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->10.4 due to current limit: Active-LoadBalancing
2025-11-07T14:40:03.429Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->17.2)
2025-11-07T14:40:03.460Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-07T14:40:03.695Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.2% (10.3 A)
2025-11-07T14:40:15.414Z:INFO:taskMain.c:5996:Socket #1: Active current 10.4->12.0 due to current limit: Active-LoadBalancing
2025-11-07T14:40:15.816Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.0% (12.0 A)
2025-11-07T14:40:23.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:40:27.414Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->15.9 due to current limit: ChargingProfile
2025-11-07T14:40:27.457Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-07T14:40:27.933Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-07T14:40:28.359Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-07T14:40:32.414Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->13.9 due to current limit: Active-LoadBalancing
2025-11-07T14:40:32.425Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->23.2)
2025-11-07T14:40:32.984Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.2% (13.9 A)
2025-11-07T14:40:39.414Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->15.9 due to current limit: ChargingProfile
2025-11-07T14:40:39.457Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-07T14:40:40.054Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-07T14:41:23.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:41:27.406Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.6 due to current limit: Active-LoadBalancing
2025-11-07T14:41:27.421Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->25.9)
2025-11-07T14:41:27.453Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-07T14:41:27.519Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.9% (15.5 A)
2025-11-07T14:41:39.406Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.0 due to current limit: Active-LoadBalancing
2025-11-07T14:41:39.417Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.9->24.9)
2025-11-07T14:41:39.636Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.9% (14.9 A)
2025-11-07T14:41:51.406Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-07T14:41:51.417Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-07T14:42:03.402Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-07T14:42:15.402Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-07T14:42:23.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:42:27.402Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-07T14:42:27.414Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.0)
2025-11-07T14:42:39.398Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-07T14:42:39.414Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.7)
2025-11-07T14:42:51.398Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-07T14:43:03.398Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.6 due to current limit: Active-LoadBalancing
2025-11-07T14:43:03.457Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.9% (15.5 A)
2025-11-07T14:43:15.394Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.8 due to current limit: Active-LoadBalancing
2025-11-07T14:43:23.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:43:27.394Z:INFO:taskMain.c:5996:Socket #1: Active current 15.8->15.6 due to current limit: Active-LoadBalancing
2025-11-07T14:43:27.406Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.2->25.9)
2025-11-07T14:43:39.394Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.4 due to current limit: Active-LoadBalancing
2025-11-07T14:43:39.406Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.9->25.6)
2025-11-07T14:43:51.394Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.2 due to current limit: Active-LoadBalancing
2025-11-07T14:43:51.406Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.6->25.3)
2025-11-07T14:44:03.390Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.4 due to current limit: Active-LoadBalancing
2025-11-07T14:44:15.390Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.6 due to current limit: Active-LoadBalancing
2025-11-07T14:44:23.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:44:27.390Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.5 due to current limit: Active-LoadBalancing
2025-11-07T14:44:27.402Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.0->25.8)
2025-11-07T14:44:37.882Z:INFO:active_lb.c:308:SMt:(16.0 16.0 16.0)A Free:(0.0 0.0 0.0)A ALB:(16.1 16.1 15.5)A
2025-11-07T14:44:39.386Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.3 due to current limit: Active-LoadBalancing
2025-11-07T14:44:39.398Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.8->25.4)
2025-11-07T14:44:51.386Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-07T14:44:51.398Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-07T14:45:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T14:45:03.386Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->25.0)
2025-11-07T14:45:15.382Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-07T14:45:15.394Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.7)
2025-11-07T14:45:23.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:45:27.382Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-07T14:45:27.394Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-07T14:45:39.382Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-07T14:45:39.394Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-07T14:45:51.378Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-07T14:46:03.378Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-07T14:46:15.378Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.4 due to current limit: Active-LoadBalancing
2025-11-07T14:46:16.355Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.6% (15.4 A)
2025-11-07T14:46:23.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:46:27.375Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.6 due to current limit: Active-LoadBalancing
2025-11-07T14:46:39.375Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.8 due to current limit: Active-LoadBalancing
2025-11-07T14:46:51.375Z:INFO:taskMain.c:5996:Socket #1: Active current 15.8->15.6 due to current limit: Active-LoadBalancing
2025-11-07T14:46:51.386Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.3->26.0)
2025-11-07T14:47:03.371Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.4 due to current limit: Active-LoadBalancing
2025-11-07T14:47:03.386Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.0->25.7)
2025-11-07T14:47:15.371Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.3 due to current limit: Active-LoadBalancing
2025-11-07T14:47:15.382Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->25.4)
2025-11-07T14:47:23.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:47:27.371Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-07T14:47:27.382Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-07T14:47:39.367Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.3 due to current limit: Active-LoadBalancing
2025-11-07T14:47:51.367Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-07T14:47:51.378Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->25.2)
2025-11-07T14:48:03.367Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-07T14:48:03.378Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-07T14:48:15.363Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-07T14:48:23.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:48:27.363Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.4 due to current limit: Active-LoadBalancing
2025-11-07T14:48:39.363Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.6 due to current limit: Active-LoadBalancing
2025-11-07T14:48:51.359Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.9 due to current limit: Active-LoadBalancing
2025-11-07T14:49:03.359Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.7 due to current limit: Active-LoadBalancing
2025-11-07T14:49:03.371Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.4->26.1)
2025-11-07T14:49:15.359Z:INFO:taskMain.c:5996:Socket #1: Active current 15.7->15.5 due to current limit: Active-LoadBalancing
2025-11-07T14:49:15.371Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.1->25.8)
2025-11-07T14:49:23.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:49:27.355Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.3 due to current limit: Active-LoadBalancing
2025-11-07T14:49:27.371Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.8->25.4)
2025-11-07T14:49:39.355Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-07T14:49:39.367Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-07T14:49:51.355Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.3 due to current limit: Active-LoadBalancing
2025-11-07T14:50:03.351Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.5 due to current limit: Active-LoadBalancing
2025-11-07T14:50:15.351Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.8 due to current limit: Active-LoadBalancing
2025-11-07T14:50:23.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:50:27.351Z:INFO:taskMain.c:5996:Socket #1: Active current 15.8->15.6 due to current limit: Active-LoadBalancing
2025-11-07T14:50:27.363Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.3->26.0)
2025-11-07T14:50:39.347Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.4 due to current limit: Active-LoadBalancing
2025-11-07T14:50:39.363Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.0->25.7)
2025-11-07T14:50:51.347Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.3 due to current limit: Active-LoadBalancing
2025-11-07T14:50:51.359Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->25.4)
2025-11-07T14:51:03.347Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-07T14:51:03.359Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-07T14:51:15.347Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.3 due to current limit: Active-LoadBalancing
2025-11-07T14:51:23.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:51:27.343Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.5 due to current limit: Active-LoadBalancing
2025-11-07T14:51:39.343Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.7 due to current limit: Active-LoadBalancing
2025-11-07T14:51:51.343Z:INFO:taskMain.c:5996:Socket #1: Active current 15.7->15.5 due to current limit: Active-LoadBalancing
2025-11-07T14:51:51.355Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.1->25.8)
2025-11-07T14:52:03.339Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.3 due to current limit: Active-LoadBalancing
2025-11-07T14:52:03.351Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.8->25.4)
2025-11-07T14:52:15.339Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-07T14:52:15.351Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-07T14:52:23.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:52:27.339Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-07T14:52:27.351Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-07T14:52:28.132Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.9V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T14:52:28.144Z:USER:taskMaster.c:6720:Socket #1: I1=14.7A I2=14.7A I3=14.6A P=10.3kW Idc=0.7mA
2025-11-07T14:52:39.335Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-07T14:52:51.335Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.3 due to current limit: Active-LoadBalancing
2025-11-07T14:53:03.335Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.5 due to current limit: Active-LoadBalancing
2025-11-07T14:53:15.332Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.3 due to current limit: Active-LoadBalancing
2025-11-07T14:53:15.343Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.8->25.5)
2025-11-07T14:53:23.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:53:27.332Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-07T14:53:27.343Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->25.2)
2025-11-07T14:53:39.332Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-07T14:53:39.343Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-07T14:53:51.328Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-07T14:54:03.328Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.4 due to current limit: Active-LoadBalancing
2025-11-07T14:54:15.328Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.6->25.6)
2025-11-07T14:54:17.171Z:USER:taskMaster.c:6582:Temperature: 30.9 C
2025-11-07T14:54:23.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:54:27.324Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.2 due to current limit: Active-LoadBalancing
2025-11-07T14:54:27.339Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.6->25.2)
2025-11-07T14:54:37.816Z:INFO:active_lb.c:308:SMt:(16.0 15.0 16.0)A Free:(0.0 1.0 0.0)A ALB:(15.2 15.9 15.3)A
2025-11-07T14:54:39.324Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-07T14:54:39.335Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-07T14:54:51.324Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-07T14:54:51.335Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-07T14:55:03.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-07T14:55:03.335Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-07T14:55:15.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-07T14:55:15.332Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-07T14:55:23.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:55:27.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-07T14:55:34.261Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-07T14:55:34.273Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-07T14:55:34.281Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-07T14:55:34.289Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-07T14:55:34.828Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-07T14:55:35.296Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.2/-11.4, tag: 04BB29EAFD0F94
2025-11-07T14:55:39.316Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->9.5 due to current limit: Active-LoadBalancing
2025-11-07T14:55:39.332Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.8% (9.5 A)
2025-11-07T14:55:51.316Z:INFO:taskMain.c:5996:Socket #1: Active current 9.5->6.1 due to current limit: Active-LoadBalancing
2025-11-07T14:55:51.445Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.1% (6.1 A)
2025-11-07T14:56:03.316Z:INFO:taskMain.c:5996:Socket #1: Active current 6.1->9.7 due to current limit: Active-LoadBalancing
2025-11-07T14:56:03.566Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.0% (9.6 A)
2025-11-07T14:56:04.308Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-07T14:56:04.320Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-07T14:56:04.574Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-07T14:56:04.582Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-07T14:56:05.304Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-07T14:56:08.308Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-07T14:56:08.335Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-07T14:56:08.343Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-07T14:56:08.808Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-07T14:56:08.816Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-07T14:56:09.343Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-07T14:56:09.835Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.2/-11.4, tag: 04BB29EAFD0F94
2025-11-07T14:56:15.312Z:INFO:taskMain.c:5996:Socket #1: Active current 9.7->11.8 due to current limit: Active-LoadBalancing
2025-11-07T14:56:15.894Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.6% (11.8 A)
2025-11-07T14:56:23.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:56:27.312Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->13.1 due to current limit: Active-LoadBalancing
2025-11-07T14:56:28.011Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.7% (13.0 A)
2025-11-07T14:56:39.312Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.8 due to current limit: Active-LoadBalancing
2025-11-07T14:56:40.132Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-07T14:56:51.308Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->14.3 due to current limit: Active-LoadBalancing
2025-11-07T14:56:52.250Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.8% (14.3 A)
2025-11-07T14:57:03.308Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-07T14:57:15.308Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T14:57:23.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:57:39.304Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T14:58:23.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T14:59:23.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:00:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T15:00:23.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:01:23.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:01:27.281Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T15:01:27.949Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T15:01:39.281Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-07T15:01:51.277Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-07T15:02:15.277Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-07T15:02:23.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:03:15.269Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-07T15:03:16.007Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-07T15:03:23.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:03:27.269Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-07T15:03:39.265Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T15:03:51.265Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.5 due to current limit: Active-LoadBalancing
2025-11-07T15:04:03.265Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T15:04:15.261Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T15:04:23.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:04:37.753Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.9 15.0)A
2025-11-07T15:04:39.261Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.5 due to current limit: Active-LoadBalancing
2025-11-07T15:04:39.832Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-07T15:04:51.257Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T15:05:03.257Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T15:05:23.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:05:27.304Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T15:05:51.304Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T15:05:51.531Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T15:06:03.300Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-07T15:06:15.300Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-07T15:06:23.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:06:39.296Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-07T15:07:15.292Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-07T15:07:15.355Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-07T15:07:23.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:07:27.292Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-07T15:07:28.035Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=235.2V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T15:07:28.054Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T15:07:39.292Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T15:08:03.289Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T15:08:23.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:08:51.285Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T15:08:51.296Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T15:09:03.281Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T15:09:17.523Z:USER:taskMaster.c:6582:Temperature: 30.6 C
2025-11-07T15:09:23.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:09:27.281Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T15:10:23.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:10:51.269Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T15:10:51.472Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T15:11:03.269Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T15:11:15.269Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.5 due to current limit: Active-LoadBalancing
2025-11-07T15:11:23.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:11:27.265Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T15:11:39.265Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T15:12:03.261Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.5 due to current limit: Active-LoadBalancing
2025-11-07T15:12:04.183Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-07T15:12:15.261Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T15:12:23.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:12:27.261Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T15:12:39.257Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.5 due to current limit: Active-LoadBalancing
2025-11-07T15:12:39.531Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-07T15:12:51.257Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T15:13:03.257Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.4 due to current limit: Active-LoadBalancing
2025-11-07T15:13:15.257Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-07T15:13:23.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:13:23.398Z:INFO:db_base.c:658:Erasing Transaction db sector 0x0000001a, address 0x0001a000 (1)
2025-11-07T15:13:23.410Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-07T15:13:27.253Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T15:13:39.253Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.5 due to current limit: Active-LoadBalancing
2025-11-07T15:13:51.253Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-07T15:14:03.250Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-07T15:14:15.250Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.3 due to current limit: Active-LoadBalancing
2025-11-07T15:14:23.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:14:27.250Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-07T15:14:37.691Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 14.6 15.0)A
2025-11-07T15:14:39.246Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T15:15:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T15:15:03.246Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T15:15:23.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:15:51.238Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T15:15:51.410Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T15:16:03.238Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T15:16:15.238Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.5 due to current limit: Active-LoadBalancing
2025-11-07T15:16:23.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:16:27.234Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T15:16:39.234Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.4 due to current limit: Active-LoadBalancing
2025-11-07T15:16:51.234Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-07T15:17:15.230Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.5 due to current limit: Active-LoadBalancing
2025-11-07T15:17:15.242Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-07T15:17:23.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:17:27.230Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-07T15:17:39.226Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->13.8 due to current limit: Active-LoadBalancing
2025-11-07T15:17:39.468Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-07T15:17:51.226Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.5 due to current limit: Active-LoadBalancing
2025-11-07T15:17:51.585Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-07T15:18:03.226Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-11-07T15:18:15.222Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-07T15:18:23.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:18:39.222Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.1 due to current limit: Active-LoadBalancing
2025-11-07T15:19:03.218Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T15:19:03.289Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T15:19:15.218Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.7 due to current limit: Active-LoadBalancing
2025-11-07T15:19:23.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:19:27.214Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-11-07T15:19:39.214Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->14.3 due to current limit: Active-LoadBalancing
2025-11-07T15:19:39.644Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.7% (14.2 A)
2025-11-07T15:19:51.214Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-07T15:20:03.210Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-11-07T15:20:15.210Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T15:20:23.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:20:27.210Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-07T15:20:39.210Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.3 due to current limit: Active-LoadBalancing
2025-11-07T15:20:51.207Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-07T15:21:03.207Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T15:21:23.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:21:27.203Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T15:21:39.203Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.5 due to current limit: Active-LoadBalancing
2025-11-07T15:21:39.812Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-07T15:21:51.203Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T15:22:03.199Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.4 due to current limit: Active-LoadBalancing
2025-11-07T15:22:15.199Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-07T15:22:23.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:22:27.199Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-07T15:22:27.941Z:USER:taskMaster.c:6684:Socket #1: L1N=235.6V L2N=236.2V L3N=235.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T15:22:27.953Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T15:22:39.195Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-11-07T15:22:51.195Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.4 due to current limit: Active-LoadBalancing
2025-11-07T15:23:03.195Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-07T15:23:15.191Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T15:23:23.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:23:39.191Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.5 due to current limit: Active-LoadBalancing
2025-11-07T15:23:51.187Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T15:24:03.187Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T15:24:17.878Z:USER:taskMaster.c:6582:Temperature: 29.8 C
2025-11-07T15:24:23.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:24:27.183Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T15:24:37.628Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 14.9 15.0)A
2025-11-07T15:25:15.179Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T15:25:15.929Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T15:25:23.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:25:27.179Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T15:25:51.175Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T15:26:03.175Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.5 due to current limit: Active-LoadBalancing
2025-11-07T15:26:03.394Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-07T15:26:15.171Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-07T15:26:23.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:26:27.171Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-07T15:26:39.171Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-07T15:26:51.167Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-07T15:27:03.167Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-07T15:27:15.167Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-07T15:27:23.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:27:27.167Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-07T15:27:51.164Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-07T15:28:15.160Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-07T15:28:15.691Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-07T15:28:23.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:28:27.160Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-07T15:28:39.160Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.4 due to current limit: Active-LoadBalancing
2025-11-07T15:28:51.156Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-07T15:29:15.156Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-07T15:29:23.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:29:39.152Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-07T15:29:39.511Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-07T15:29:51.152Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-07T15:30:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T15:30:03.148Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-07T15:30:23.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:30:39.144Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-07T15:30:40.105Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-07T15:30:51.144Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-07T15:31:03.144Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-07T15:31:15.140Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.3 due to current limit: Active-LoadBalancing
2025-11-07T15:31:23.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:31:27.140Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-07T15:31:39.140Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T15:31:51.136Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.5 due to current limit: Active-LoadBalancing
2025-11-07T15:31:51.808Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-07T15:32:03.136Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-07T15:32:15.136Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-07T15:32:23.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:32:27.132Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.3 due to current limit: Active-LoadBalancing
2025-11-07T15:32:39.132Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-07T15:32:41.332Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-07T15:32:41.339Z:INFO:db_chargingprofi:26: socket 0
2025-11-07T15:32:41.347Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-07T15:32:41.355Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-07T15:32:41.363Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-07T15:32:41.371Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-07T15:32:41.382Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-07T15:32:41.390Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-07T15:32:41.402Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-07T15:32:41.410Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-07T15:32:41.417Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-07T15:32:41.425Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-07T15:32:41.437Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-07T15:32:41.445Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-07T15:32:41.453Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-07T15:32:41.460Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-07T15:32:41.472Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-07T15:32:41.480Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-07T15:32:41.488Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-07T15:32:41.496Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-07T15:32:41.503Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-07T15:32:41.511Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-07T15:32:41.519Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-07T15:33:03.128Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-07T15:33:23.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:33:51.125Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-07T15:33:51.976Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-07T15:34:03.125Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-07T15:34:15.121Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T15:34:23.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:34:29.164Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-07T15:34:29.175Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-07T15:34:37.566Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(14.9 14.9 15.0)A
2025-11-07T15:34:39.121Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.5 due to current limit: Active-LoadBalancing
2025-11-07T15:34:51.121Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T15:35:03.117Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T15:35:23.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:35:27.117Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T15:36:03.113Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T15:36:03.261Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T15:36:15.109Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-07T15:36:23.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:36:27.109Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-07T15:36:51.105Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-07T15:37:23.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:37:27.847Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=236.2V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T15:37:27.859Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T15:37:51.101Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.3 due to current limit: Active-LoadBalancing
2025-11-07T15:38:03.097Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-07T15:38:15.097Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-11-07T15:38:23.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:38:27.097Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.4 due to current limit: Active-LoadBalancing
2025-11-07T15:38:39.093Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-07T15:38:51.093Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-07T15:39:15.089Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-07T15:39:18.285Z:USER:taskMaster.c:6582:Temperature: 29.1 C
2025-11-07T15:39:23.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:39:51.085Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-07T15:39:51.496Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-07T15:40:03.085Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-07T15:40:15.085Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-11-07T15:40:23.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:40:39.082Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.1 due to current limit: Active-LoadBalancing
2025-11-07T15:41:23.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:42:23.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:43:23.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:44:23.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:44:37.500Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-07T15:45:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T15:45:23.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:46:23.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:46:27.046Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-11-07T15:46:27.375Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-11-07T15:46:39.042Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-11-07T15:47:03.042Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.5 due to current limit: Active-LoadBalancing
2025-11-07T15:47:03.730Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-07T15:47:15.039Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-07T15:47:23.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:47:27.039Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.4 due to current limit: Active-LoadBalancing
2025-11-07T15:47:39.039Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.7 due to current limit: Active-LoadBalancing
2025-11-07T15:47:51.035Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-07T15:48:15.035Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T15:48:23.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:49:15.328Z:WARNING:taskMain.c:4758:Socket #1: EV disconnected while charging (11.1V)
2025-11-07T15:49:15.371Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAIT_FOR_EV_RECONNECT
2025-11-07T15:49:15.382Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_A
2025-11-07T15:49:16.027Z:INFO:taskMain.c:6494:Socket #1: CPhigh 12.3 V
2025-11-07T15:49:16.035Z:INFO:taskMain.c:6499:Socket #1: CPlow 12.3 V
2025-11-07T15:49:16.359Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAIT_FOR_EV_RECONNECT, CP: 12.3/12.4, tag: 04BB2
2025-11-07T15:49:16.359Z:INFO:taskMain.c:1417:9EAFD0F94
2025-11-07T15:49:23.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:49:25.371Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_TERMINATING
2025-11-07T15:49:25.582Z:INFO:db_transaction.c:16:Added TransactionStop for socket 1 at 0x0001a9c0 (ts: 2242-03-16 12:56:31)
2025-11-07T15:49:25.593Z:INFO:db_transaction.c:16:Updated TransactionStart for socket 1 at 0x000194f4 (ts: 2025-11-07 14:32:22)
2025-11-07T15:49:25.609Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_VEHICLE
2025-11-07T15:49:26.367Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_TERMINATING, CP: 12.4/12.4, tag: 04BB29EAFD0F94
2025-11-07T15:49:27.027Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-11-07T15:49:27.375Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-07T15:49:29.371Z:INFO:taskMaster.c:4957:Socket #1: state main : WAIT_FOR_STOP_METERVALUE
2025-11-07T15:49:30.246Z:INFO:taskMain.c:938:Socket #1: charging session status set inactive
2025-11-07T15:49:30.257Z:USER:board_ng9xx.c:5068:Socket #1: unlock socket motor
2025-11-07T15:49:30.269Z:INFO:taskMaster.c:4957:Socket #1: state main : WAIT_FOR_DISCONNECT
2025-11-07T15:49:30.503Z:INFO:db_transaction.c:16:Updated TransactionStop for socket 1 at 0x0001a9c0 (ts: 2025-11-07 15:49:30)
2025-11-07T15:49:30.566Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_DISCONNECT
2025-11-07T15:49:31.296Z:INFO:taskMain.c:1417:Socket #1: main state: WAIT_FOR_DISCONNECT, CP: 12.3/12.3, tag: 04BB29EAFD0F94
2025-11-07T15:49:39.027Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-11-07T15:50:00.281Z:USER:board_ng9xx.c:5068:Socket #1: unlock socket motor (forced)
2025-11-07T15:50:03.023Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.5 due to current limit: Active-LoadBalancing
2025-11-07T15:50:03.613Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-07T15:50:15.023Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-07T15:50:26.839Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-07T15:50:26.847Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-07T15:50:27.019Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-07T15:50:30.613Z:USER:tag.c:1623:Reader 0 Got NFC tag: 04BB29EAFD0F94
2025-11-07T15:50:33.167Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->0.0 due to current limit: Cable
2025-11-07T15:50:33.261Z:INFO:taskMaster.c:4957:Socket #1: state main : AVAILABLE
2025-11-07T15:50:33.281Z:INFO:taskMain.c:6440:Socket #1: active tag cleared
2025-11-07T15:50:33.324Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-07T15:50:33.332Z:INFO:taskMaster.c:4979:Socket #1: state led : AVAILABLE
2025-11-07T15:50:33.910Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-07T15:50:33.917Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-07T15:50:33.925Z:INFO:taskMain.c:6504:Socket #1: PP 34464 Ohm (0 A)
2025-11-07T15:50:34.257Z:INFO:taskMain.c:1419:Socket #1: main state: AVAILABLE, CP: 0.0/0.0, no tag
2025-11-07T15:50:59.878Z:INFO:taskMain.c:5996:Socket #1: Active current 0.0->12.1 due to current limit: Active-LoadBalancing
2025-11-07T15:50:59.910Z:INFO:taskMaster.c:4957:Socket #1: state main : CABLE_CONNECTED
2025-11-07T15:50:59.921Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_A
2025-11-07T15:50:59.929Z:INFO:taskMaster.c:4979:Socket #1: state led : CABLE_CONNECTED
2025-11-07T15:51:00.515Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-07T15:51:00.523Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-07T15:51:00.531Z:INFO:taskMain.c:6504:Socket #1: PP 699 Ohm (20 A)
2025-11-07T15:51:00.945Z:INFO:taskMain.c:1419:Socket #1: main state: CABLE_CONNECTED, CP: 9.3/0.9, no tag
2025-11-07T15:51:01.960Z:INFO:taskMaster.c:4957:Socket #1: state main : EV_CONNECTED_UNAUTHORIZED
2025-11-07T15:51:01.972Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-07T15:51:02.957Z:INFO:taskMain.c:1419:Socket #1: main state: EV_CONNECTED_UNAUTHORIZED, CP: 9.3/0.9, no tag
2025-11-07T15:51:03.460Z:USER:tag.c:1623:Reader 0 Got NFC tag: 04BB29EAFD0F94
2025-11-07T15:51:03.660Z:USER:taskMaster.c:6931:Socket #1: has reliable metervalue
2025-11-07T15:51:03.667Z:INFO:taskMaster.c:1604:1 cables attached
2025-11-07T15:51:03.710Z:INFO:taskMaster.c:4979:Socket #1: state led : AUTHORISING
2025-11-07T15:51:03.722Z:USER:tag.c:584:Tag 04BB29EAFD0F94 is authorised by white list
2025-11-07T15:51:03.761Z:USER:taskMaster.c:1914:Multiple cables attached, prioritizing socket #1
2025-11-07T15:51:03.804Z:USER:board_ng9xx.c:5068:Socket #1: lock socket motor
2025-11-07T15:51:03.816Z:INFO:taskMaster.c:4957:Socket #1: state main : EV_CONNECTED_AUTHORIZED
2025-11-07T15:51:04.027Z:INFO:taskMaster.c:7497:New charging session started, metervalue=5635260.000
2025-11-07T15:51:04.042Z:INFO:db_transaction.c:16:Added TransactionStart for socket 1 at 0x0001a9f1 (ts: 2025-11-07 15:51:03)
2025-11-07T15:51:04.066Z:INFO:taskMaster.c:4979:Socket #1: state led : EV_CONNECTED
2025-11-07T15:51:04.074Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:51:04.816Z:INFO:taskMain.c:1417:Socket #1: main state: EV_CONNECTED_AUTHORIZED, CP: 9.2/9.2, tag: 04BB29EAFD0F94
2025-11-07T15:51:04.875Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.4 due to current limit: Active-LoadBalancing
2025-11-07T15:51:04.906Z:INFO:taskMain.c:938:Socket #1: charging session status set active
2025-11-07T15:51:04.914Z:INFO:taskMaster.c:4957:Socket #1: state main : WAIT_FOR_START_METERVALUE
2025-11-07T15:51:04.925Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_PREPARING
2025-11-07T15:51:05.828Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-11-07T15:51:06.015Z:INFO:taskMain.c:1417:Socket #1: main state: WAIT_FOR_START_METERVALUE, CP: 9.3/9.3, tag: 04BB29EAFD0F
2025-11-07T15:51:06.015Z:INFO:taskMain.c:1417:94
2025-11-07T15:51:07.960Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-07T15:51:07.968Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-07T15:51:08.011Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-07T15:51:08.035Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-07T15:51:08.910Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-07T15:51:08.917Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-07T15:51:08.929Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=234.3V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T15:51:08.941Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T15:51:08.953Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-07T15:51:08.960Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-07T15:51:08.968Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-07T15:51:09.046Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-07T15:51:09.894Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-07T15:51:15.015Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->15.9 due to current limit: ChargingProfile
2025-11-07T15:51:15.058Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-07T15:51:15.957Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-07T15:51:38.957Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=232.9V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T15:51:38.968Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.6A I3=15.4A P=10.8kW Idc=0.7mA
2025-11-07T15:51:51.011Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->10.9 due to current limit: Active-LoadBalancing
2025-11-07T15:51:51.023Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->18.1)
2025-11-07T15:51:51.054Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-07T15:51:51.300Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.1% (10.9 A)
2025-11-07T15:52:03.011Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.5 due to current limit: Active-LoadBalancing
2025-11-07T15:52:03.421Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.1% (11.5 A)
2025-11-07T15:52:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:52:08.878Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-07T15:52:08.953Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.1V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T15:52:08.964Z:USER:taskMaster.c:6720:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-11-07T15:52:15.007Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.9 due to current limit: Active-LoadBalancing
2025-11-07T15:52:15.539Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.8% (11.9 A)
2025-11-07T15:52:22.109Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->14.1 due to current limit: Active-LoadBalancing
2025-11-07T15:52:22.609Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.4% (14.0 A)
2025-11-07T15:52:27.050Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-07T15:52:27.109Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->15.9 due to current limit: ChargingProfile
2025-11-07T15:52:27.656Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-07T15:52:38.949Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=232.2V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T15:52:38.960Z:USER:taskMaster.c:6720:Socket #1: I1=15.6A I2=15.5A I3=15.4A P=10.8kW Idc=0.7mA
2025-11-07T15:52:51.003Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->9.8 due to current limit: Active-LoadBalancing
2025-11-07T15:52:51.019Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->16.4)
2025-11-07T15:52:51.050Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-07T15:52:51.894Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.4% (9.8 A)
2025-11-07T15:53:03.003Z:INFO:taskMain.c:5996:Socket #1: Active current 9.8->13.7 due to current limit: Active-LoadBalancing
2025-11-07T15:53:03.015Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.8% (13.7 A)
2025-11-07T15:53:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:53:08.949Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=232.6V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T15:53:08.960Z:USER:taskMaster.c:6720:Socket #1: I1=13.2A I2=13.3A I3=13.3A P=9.2kW Idc=0.7mA
2025-11-07T15:53:15.003Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->15.2 due to current limit: Active-LoadBalancing
2025-11-07T15:53:15.121Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.3% (15.2 A)
2025-11-07T15:53:27.000Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.1 due to current limit: Active-LoadBalancing
2025-11-07T15:53:27.015Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-07T15:53:38.945Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=232.4V L3N=231.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T15:53:38.957Z:USER:taskMaster.c:6720:Socket #1: I1=14.6A I2=14.7A I3=14.6A P=10.2kW Idc=0.7mA
2025-11-07T15:53:39.000Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.1 due to current limit: Active-LoadBalancing
2025-11-07T15:53:39.011Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->23.5)
2025-11-07T15:53:39.359Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.5% (14.1 A)
2025-11-07T15:53:51.000Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->13.2 due to current limit: Active-LoadBalancing
2025-11-07T15:53:51.011Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.5->21.9)
2025-11-07T15:53:51.480Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.9% (13.1 A)
2025-11-07T15:54:02.996Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.0 due to current limit: Active-LoadBalancing
2025-11-07T15:54:03.011Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.9->21.7)
2025-11-07T15:54:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:54:08.941Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=232.7V L3N=231.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T15:54:08.953Z:USER:taskMaster.c:6720:Socket #1: I1=12.6A I2=12.7A I3=12.6A P=8.8kW Idc=0.7mA
2025-11-07T15:54:14.996Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.9 due to current limit: Active-LoadBalancing
2025-11-07T15:54:15.007Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.7->21.4)
2025-11-07T15:54:19.089Z:USER:taskMaster.c:6582:Temperature: 28.9 C
2025-11-07T15:54:19.589Z:INFO:EVCapabilities.c:24:Socket #1 EV: #phases supported: 3
2025-11-07T15:54:26.996Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.7 due to current limit: Active-LoadBalancing
2025-11-07T15:54:27.007Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.4->21.2)
2025-11-07T15:54:37.437Z:INFO:active_lb.c:308:SMt:(14.0 16.0 13.0)A Free:(2.0 0.0 3.0)A ALB:(15.0 12.7 15.2)A
2025-11-07T15:54:38.937Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=232.4V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T15:54:38.949Z:USER:taskMaster.c:6720:Socket #1: I1=12.3A I2=12.4A I3=12.3A P=8.6kW Idc=0.7mA
2025-11-07T15:54:38.992Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.6 due to current limit: Active-LoadBalancing
2025-11-07T15:54:39.007Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.2->20.9)
2025-11-07T15:54:50.992Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-11-07T15:54:51.003Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.9->20.7)
2025-11-07T15:55:02.992Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.7 due to current limit: Active-LoadBalancing
2025-11-07T15:55:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:55:08.933Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=232.7V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T15:55:08.945Z:USER:taskMaster.c:6720:Socket #1: I1=12.3A I2=12.3A I3=12.3A P=8.6kW Idc=0.7mA
2025-11-07T15:55:14.988Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.5 due to current limit: Active-LoadBalancing
2025-11-07T15:55:15.003Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.1->20.8)
2025-11-07T15:55:26.988Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-07T15:55:27.000Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.8->20.5)
2025-11-07T15:55:37.882Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-07T15:55:37.890Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-07T15:55:37.902Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-07T15:55:37.910Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-07T15:55:38.527Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-07T15:55:38.898Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-07T15:55:38.933Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=233.4V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T15:55:38.945Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T15:55:38.988Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->7.8 due to current limit: Active-LoadBalancing
2025-11-07T15:55:39.906Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.0% (7.8 A)
2025-11-07T15:55:50.988Z:INFO:taskMain.c:5996:Socket #1: Active current 7.8->5.1 due to current limit: Active-LoadBalancing
2025-11-07T15:55:51.000Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.08) < minimum current(6.00)
2025-11-07T15:55:51.019Z:INFO:taskMain.c:6499:Socket #1: CPlow 4.5 V
2025-11-07T15:55:51.031Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-07T15:55:51.042Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-07T15:55:51.050Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-07T15:55:52.027Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-07T15:55:52.035Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.2/9.2, tag: 04BB
2025-11-07T15:55:52.035Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-07T15:56:02.984Z:INFO:taskMain.c:5996:Socket #1: Active current 5.1->7.9 due to current limit: Active-LoadBalancing
2025-11-07T15:56:03.027Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-07T15:56:03.039Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-07T15:56:03.046Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-07T15:56:03.136Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-07T15:56:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:56:04.039Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-07T15:56:08.929Z:USER:taskMaster.c:6684:Socket #1: L1N=233.4V L2N=233.1V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T15:56:08.941Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T15:56:08.949Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-07T15:56:14.984Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->10.3 due to current limit: Active-LoadBalancing
2025-11-07T15:56:15.144Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.1% (10.3 A)
2025-11-07T15:56:26.984Z:INFO:taskMain.c:5996:Socket #1: Active current 10.3->11.8 due to current limit: Active-LoadBalancing
2025-11-07T15:56:27.261Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.6% (11.8 A)
2025-11-07T15:56:33.074Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-07T15:56:33.085Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-07T15:56:33.320Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-07T15:56:33.328Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-07T15:56:34.070Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-07T15:56:37.074Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-07T15:56:37.101Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-07T15:56:37.109Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-07T15:56:37.574Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-07T15:56:37.585Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-07T15:56:38.113Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-07T15:56:38.601Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-07T15:56:38.980Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->12.7 due to current limit: Active-LoadBalancing
2025-11-07T15:56:39.609Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.1% (12.7 A)
2025-11-07T15:56:50.980Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->13.2 due to current limit: Active-LoadBalancing
2025-11-07T15:56:51.730Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.0% (13.2 A)
2025-11-07T15:57:02.980Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.5 due to current limit: Active-LoadBalancing
2025-11-07T15:57:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:57:14.976Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-11-07T15:57:26.976Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-11-07T15:57:50.972Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-07T15:58:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:59:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T15:59:26.964Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-07T15:59:27.253Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-07T15:59:38.960Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-07T15:59:50.960Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->12.8 due to current limit: Active-LoadBalancing
2025-11-07T15:59:51.492Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.3% (12.8 A)
2025-11-07T16:00:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T16:00:02.960Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-11-07T16:00:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:00:14.957Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-07T16:00:26.957Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-07T16:00:38.957Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-11-07T16:00:38.968Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-07T16:00:50.953Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-07T16:01:02.953Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-07T16:01:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:01:26.949Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T16:02:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:03:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:04:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:04:37.375Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(14.4 13.0 15.0)A
2025-11-07T16:05:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:06:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:07:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:07:38.910Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T16:07:39.070Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T16:07:50.910Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-07T16:08:02.910Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-07T16:08:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:08:26.906Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-07T16:09:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:09:19.445Z:USER:taskMaster.c:6582:Temperature: 28.9 C
2025-11-07T16:09:37.296Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-11-07T16:10:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:10:50.890Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-07T16:10:50.953Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-07T16:11:02.890Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-07T16:11:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:11:08.832Z:USER:taskMaster.c:6684:Socket #1: L1N=230.7V L2N=230.3V L3N=230.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T16:11:08.843Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T16:11:14.890Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->12.8 due to current limit: Active-LoadBalancing
2025-11-07T16:11:15.187Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.3% (12.8 A)
2025-11-07T16:11:26.886Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-11-07T16:11:38.886Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-07T16:11:50.886Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-07T16:12:02.882Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-11-07T16:12:03.664Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-07T16:12:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:12:14.882Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-07T16:12:26.882Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-07T16:12:50.878Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T16:13:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:13:04.421Z:INFO:db_base.c:658:Erasing Transaction db sector 0x0000001b, address 0x0001b000 (1)
2025-11-07T16:13:04.433Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-07T16:14:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:14:37.312Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-07T16:15:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T16:15:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:16:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:17:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:18:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:19:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:19:37.335Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-11-07T16:19:38.835Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T16:19:39.125Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T16:19:50.835Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-07T16:20:02.832Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-07T16:20:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:20:26.832Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-07T16:21:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:21:50.820Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-07T16:21:51.421Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-07T16:22:02.820Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-07T16:22:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:22:26.816Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-07T16:22:50.816Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.6 due to current limit: Active-LoadBalancing
2025-11-07T16:22:51.003Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-07T16:23:02.812Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-07T16:23:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:23:14.812Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->12.8 due to current limit: Active-LoadBalancing
2025-11-07T16:23:15.242Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.3% (12.8 A)
2025-11-07T16:23:26.812Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-11-07T16:23:38.808Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-07T16:23:50.808Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-07T16:24:02.808Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-11-07T16:24:03.718Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-07T16:24:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:24:14.808Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-07T16:24:19.851Z:USER:taskMaster.c:6582:Temperature: 28.1 C
2025-11-07T16:24:26.804Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-07T16:24:37.250Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 12.8 14.0)A
2025-11-07T16:24:50.804Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T16:25:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:26:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:26:08.738Z:USER:taskMaster.c:6684:Socket #1: L1N=235.9V L2N=235.3V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T16:26:08.750Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T16:27:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:28:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:28:50.777Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.2 due to current limit: Active-LoadBalancing
2025-11-07T16:28:51.527Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.3% (12.2 A)
2025-11-07T16:29:02.777Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-11-07T16:29:03.644Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-07T16:29:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:29:14.773Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-07T16:29:26.773Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-07T16:29:37.269Z:INFO:taskLeds.c:338:Brightness set to 8%
2025-11-07T16:29:50.769Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T16:30:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T16:30:02.769Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.6 due to current limit: Active-LoadBalancing
2025-11-07T16:30:03.230Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-07T16:30:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:30:14.769Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.3 due to current limit: Active-LoadBalancing
2025-11-07T16:30:26.765Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->13.0 due to current limit: Active-LoadBalancing
2025-11-07T16:30:27.468Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.6% (13.0 A)
2025-11-07T16:30:38.765Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T16:30:39.585Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T16:30:50.765Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-07T16:31:02.765Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-07T16:31:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:31:26.761Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-07T16:32:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:32:46.300Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-07T16:32:46.308Z:INFO:db_chargingprofi:26: socket 0
2025-11-07T16:32:46.316Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-07T16:32:46.324Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-07T16:32:46.332Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-07T16:32:46.343Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-07T16:32:46.351Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-07T16:32:46.363Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-07T16:32:46.371Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-07T16:32:46.378Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-07T16:32:46.386Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-07T16:32:46.394Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-07T16:32:46.402Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-07T16:32:46.410Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-07T16:32:46.417Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-07T16:32:46.429Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-07T16:32:46.437Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-07T16:32:46.445Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-07T16:32:46.453Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-07T16:32:46.460Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-07T16:32:46.468Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-07T16:32:46.476Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-07T16:32:46.484Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-07T16:33:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:33:26.750Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-07T16:33:27.226Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-07T16:33:38.746Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.0 due to current limit: Active-LoadBalancing
2025-11-07T16:33:39.347Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.5% (12.9 A)
2025-11-07T16:33:50.746Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-11-07T16:33:51.464Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-07T16:34:02.746Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.3 due to current limit: Active-LoadBalancing
2025-11-07T16:34:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:34:14.742Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-07T16:34:37.183Z:INFO:active_lb.c:308:SMt:(1.0 4.0 2.0)A Free:(15.0 12.0 14.0)A ALB:(15.0 12.1 14.0)A
2025-11-07T16:34:38.742Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.1 due to current limit: Active-LoadBalancing
2025-11-07T16:34:50.738Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.4 due to current limit: Active-LoadBalancing
2025-11-07T16:34:51.050Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-11-07T16:35:02.738Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.7 due to current limit: Active-LoadBalancing
2025-11-07T16:35:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:35:14.738Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-07T16:35:38.734Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T16:36:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:37:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:38:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:39:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:39:20.253Z:USER:taskMaster.c:6582:Temperature: 27.4 C
2025-11-07T16:40:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:41:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:41:08.644Z:USER:taskMaster.c:6684:Socket #1: L1N=232.5V L2N=231.1V L3N=231.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T16:41:08.656Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T16:42:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:42:26.742Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T16:42:27.523Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T16:42:38.742Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-07T16:42:50.738Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-07T16:43:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:43:14.738Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-07T16:44:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:44:37.121Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(15.0 14.4 14.0)A
2025-11-07T16:45:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T16:45:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:45:50.718Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.1 due to current limit: Active-LoadBalancing
2025-11-07T16:45:51.519Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.8% (13.1 A)
2025-11-07T16:46:02.718Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.7 due to current limit: Active-LoadBalancing
2025-11-07T16:46:03.640Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.1% (12.7 A)
2025-11-07T16:46:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:46:14.718Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.4 due to current limit: Active-LoadBalancing
2025-11-07T16:46:26.714Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-11-07T16:46:38.714Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-11-07T16:46:38.984Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-07T16:46:50.714Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-07T16:47:02.710Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-07T16:47:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:47:26.710Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T16:48:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:49:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:50:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:51:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:52:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:53:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:54:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:54:20.609Z:USER:taskMaster.c:6582:Temperature: 26.9 C
2025-11-07T16:54:37.058Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-11-07T16:55:02.710Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T16:55:02.921Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T16:55:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:55:14.710Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-07T16:55:26.710Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-07T16:55:50.707Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-07T16:56:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:56:08.550Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=231.3V L3N=231.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T16:56:08.562Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T16:57:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:58:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:58:14.691Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.8 due to current limit: Active-LoadBalancing
2025-11-07T16:58:26.691Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.1 due to current limit: Active-LoadBalancing
2025-11-07T16:58:26.921Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.8% (13.1 A)
2025-11-07T16:58:38.687Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.7 due to current limit: Active-LoadBalancing
2025-11-07T16:58:39.039Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-11-07T16:58:50.687Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.4 due to current limit: Active-LoadBalancing
2025-11-07T16:59:02.687Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-11-07T16:59:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T16:59:14.683Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-11-07T16:59:15.394Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-07T16:59:26.683Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-07T16:59:38.683Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-07T17:00:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T17:00:02.679Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T17:00:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:01:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:02:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:03:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:04:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:04:36.996Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-11-07T17:05:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:06:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:06:26.640Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T17:06:27.628Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T17:06:38.636Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-07T17:06:50.636Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-07T17:07:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:07:14.636Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-07T17:08:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:09:02.625Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-07T17:09:03.152Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-07T17:09:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:09:14.621Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-07T17:09:21.015Z:USER:taskMaster.c:6582:Temperature: 26.6 C
2025-11-07T17:09:26.621Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-11-07T17:09:38.621Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.5 due to current limit: Active-LoadBalancing
2025-11-07T17:09:50.617Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.1 due to current limit: Active-LoadBalancing
2025-11-07T17:09:50.632Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.8% (13.1 A)
2025-11-07T17:10:02.617Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.7 due to current limit: Active-LoadBalancing
2025-11-07T17:10:02.738Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-11-07T17:10:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:10:14.617Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.4 due to current limit: Active-LoadBalancing
2025-11-07T17:10:26.613Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-11-07T17:10:38.613Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-11-07T17:10:39.093Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-07T17:10:50.613Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-07T17:11:02.609Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-07T17:11:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:11:08.453Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=234.3V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T17:11:08.464Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T17:11:26.609Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T17:12:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:13:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:14:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:14:04.386Z:INFO:db_base.c:658:Erasing Transaction db sector 0x0000001c, address 0x0001c000 (1)
2025-11-07T17:14:04.398Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-07T17:14:36.933Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-11-07T17:14:38.589Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T17:14:39.449Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T17:14:50.585Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-07T17:15:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T17:15:02.585Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-07T17:15:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:15:26.582Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->14.0 due to current limit: Active-LoadBalancing
2025-11-07T17:16:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:17:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:17:26.570Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-07T17:17:27.089Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-07T17:17:38.570Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-07T17:17:50.566Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->12.8 due to current limit: Active-LoadBalancing
2025-11-07T17:17:51.328Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.3% (12.8 A)
2025-11-07T17:18:02.566Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-11-07T17:18:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:18:14.566Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-07T17:18:26.562Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-07T17:18:38.562Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-11-07T17:18:38.792Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-07T17:18:50.562Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-07T17:19:02.558Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-07T17:19:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:19:26.558Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T17:20:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:21:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:22:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:22:38.539Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T17:22:39.148Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T17:22:50.535Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-07T17:23:02.535Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-07T17:23:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:23:26.531Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-07T17:24:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:24:21.371Z:USER:taskMaster.c:6582:Temperature: 26.5 C
2025-11-07T17:24:36.867Z:INFO:active_lb.c:308:SMt:(1.0 2.0 2.0)A Free:(15.0 14.0 14.0)A ALB:(15.0 14.0 14.0)A
2025-11-07T17:25:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:26:02.515Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.7 due to current limit: Active-LoadBalancing
2025-11-07T17:26:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:26:08.359Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=231.6V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T17:26:08.371Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T17:26:14.515Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.4 due to current limit: Active-LoadBalancing
2025-11-07T17:26:26.511Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.3 due to current limit: Active-LoadBalancing
2025-11-07T17:26:38.511Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-07T17:27:02.507Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.9 due to current limit: Active-LoadBalancing
2025-11-07T17:27:02.730Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-07T17:27:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:27:14.507Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.6 due to current limit: Active-LoadBalancing
2025-11-07T17:27:26.507Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.0 due to current limit: Active-LoadBalancing
2025-11-07T17:27:26.968Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.5% (12.9 A)
2025-11-07T17:27:38.503Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-11-07T17:27:39.085Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-07T17:27:50.503Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.3 due to current limit: Active-LoadBalancing
2025-11-07T17:28:02.503Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-07T17:28:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:28:14.503Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-11-07T17:28:15.441Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-07T17:28:26.500Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-07T17:28:38.500Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-07T17:29:02.496Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T17:29:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:30:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T17:30:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:31:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:32:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:32:14.476Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T17:32:14.785Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T17:32:26.476Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-07T17:32:38.472Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-07T17:32:53.871Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-07T17:32:53.878Z:INFO:db_chargingprofi:26: socket 0
2025-11-07T17:32:53.886Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-07T17:32:53.894Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-07T17:32:53.902Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-07T17:32:53.914Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-07T17:32:53.921Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-07T17:32:53.929Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-07T17:32:53.941Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-07T17:32:53.949Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-07T17:32:53.957Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-07T17:32:53.964Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-07T17:32:53.972Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-07T17:32:53.980Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-07T17:32:53.988Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-07T17:32:54.000Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-07T17:32:54.007Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-07T17:32:54.015Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-07T17:32:54.023Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-07T17:32:54.031Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-07T17:32:54.039Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-07T17:32:54.046Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-07T17:32:54.058Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-07T17:33:02.472Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-07T17:33:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:34:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:34:23.074Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-07T17:34:23.343Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-07T17:34:28.406Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-07T17:34:28.417Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-07T17:34:36.804Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(15.0 15.0 14.0)A
2025-11-07T17:35:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:36:02.453Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.8 due to current limit: Active-LoadBalancing
2025-11-07T17:36:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:36:14.453Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.5 due to current limit: Active-LoadBalancing
2025-11-07T17:36:15.140Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-07T17:36:26.449Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-11-07T17:36:38.449Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->12.8 due to current limit: Active-LoadBalancing
2025-11-07T17:36:39.378Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.2% (12.7 A)
2025-11-07T17:36:50.449Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-11-07T17:37:02.445Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-07T17:37:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:37:14.445Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-07T17:37:38.441Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T17:38:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:39:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:39:21.777Z:USER:taskMaster.c:6582:Temperature: 26.1 C
2025-11-07T17:40:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:40:50.421Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T17:40:50.843Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T17:41:02.421Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-07T17:41:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:41:08.265Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=233.5V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T17:41:08.277Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T17:41:14.417Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-07T17:41:38.417Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-07T17:42:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:43:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:44:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:44:36.742Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(14.9 14.0 14.0)A
2025-11-07T17:44:38.398Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-07T17:44:39.078Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.7% (13.6 A)
2025-11-07T17:44:50.398Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.0 due to current limit: Active-LoadBalancing
2025-11-07T17:44:51.195Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.6% (13.0 A)
2025-11-07T17:45:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T17:45:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:45:26.394Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-11-07T17:45:26.542Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-07T17:45:38.390Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-11-07T17:46:02.390Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T17:46:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:46:50.382Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->11.2 due to current limit: Active-LoadBalancing
2025-11-07T17:46:51.375Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.6% (11.2 A)
2025-11-07T17:47:02.382Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->9.5 due to current limit: Active-LoadBalancing
2025-11-07T17:47:02.484Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.8% (9.5 A)
2025-11-07T17:47:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:47:14.382Z:INFO:taskMain.c:5996:Socket #1: Active current 9.5->8.5 due to current limit: Active-LoadBalancing
2025-11-07T17:47:14.601Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.1% (8.5 A)
2025-11-07T17:47:26.378Z:INFO:taskMain.c:5996:Socket #1: Active current 8.5->7.9 due to current limit: Active-LoadBalancing
2025-11-07T17:47:26.718Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.1% (7.9 A)
2025-11-07T17:47:38.378Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->7.5 due to current limit: Active-LoadBalancing
2025-11-07T17:47:38.839Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.5% (7.5 A)
2025-11-07T17:47:50.378Z:INFO:taskMain.c:5996:Socket #1: Active current 7.5->7.3 due to current limit: Active-LoadBalancing
2025-11-07T17:48:02.375Z:INFO:taskMain.c:5996:Socket #1: Active current 7.3->7.2 due to current limit: Active-LoadBalancing
2025-11-07T17:48:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:48:26.375Z:INFO:taskMain.c:5996:Socket #1: Active current 7.1->7.5 due to current limit: Active-LoadBalancing
2025-11-07T17:48:27.312Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.4% (7.4 A)
2025-11-07T17:48:38.371Z:INFO:taskMain.c:5996:Socket #1: Active current 7.5->7.7 due to current limit: Active-LoadBalancing
2025-11-07T17:48:50.371Z:INFO:taskMain.c:5996:Socket #1: Active current 7.7->8.2 due to current limit: Active-LoadBalancing
2025-11-07T17:48:50.542Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.6% (8.2 A)
2025-11-07T17:49:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:49:14.371Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->8.5 due to current limit: Active-LoadBalancing
2025-11-07T17:49:14.777Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.1% (8.5 A)
2025-11-07T17:49:26.367Z:INFO:taskMain.c:5996:Socket #1: Active current 8.5->8.3 due to current limit: Active-LoadBalancing
2025-11-07T17:49:38.367Z:INFO:taskMain.c:5996:Socket #1: Active current 8.3->8.6 due to current limit: Active-LoadBalancing
2025-11-07T17:49:50.367Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.7 due to current limit: Active-LoadBalancing
2025-11-07T17:50:02.363Z:INFO:taskMain.c:5996:Socket #1: Active current 8.7->8.8 due to current limit: Active-LoadBalancing
2025-11-07T17:50:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:50:38.359Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->9.0 due to current limit: Active-LoadBalancing
2025-11-07T17:51:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:51:14.355Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->10.2 due to current limit: Active-LoadBalancing
2025-11-07T17:51:14.957Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.9% (10.1 A)
2025-11-07T17:51:26.355Z:INFO:taskMain.c:5996:Socket #1: Active current 10.2->11.7 due to current limit: Active-LoadBalancing
2025-11-07T17:51:27.074Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.5% (11.7 A)
2025-11-07T17:51:38.355Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->12.6 due to current limit: Active-LoadBalancing
2025-11-07T17:51:39.195Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-11-07T17:51:50.351Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.0 due to current limit: Active-LoadBalancing
2025-11-07T17:51:51.312Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.9% (11.9 A)
2025-11-07T17:52:02.351Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->11.6 due to current limit: Active-LoadBalancing
2025-11-07T17:52:02.421Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.3% (11.6 A)
2025-11-07T17:52:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:52:14.351Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->12.6 due to current limit: Active-LoadBalancing
2025-11-07T17:52:14.539Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-07T17:52:26.347Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->13.1 due to current limit: Active-LoadBalancing
2025-11-07T17:52:26.660Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.8% (13.1 A)
2025-11-07T17:52:38.347Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.5 due to current limit: Active-LoadBalancing
2025-11-07T17:52:38.777Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-07T17:52:50.347Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.4 due to current limit: Active-LoadBalancing
2025-11-07T17:53:02.343Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->12.8 due to current limit: Active-LoadBalancing
2025-11-07T17:53:03.015Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.3% (12.8 A)
2025-11-07T17:53:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:53:26.343Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.5 due to current limit: Active-LoadBalancing
2025-11-07T17:53:27.253Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-07T17:53:38.339Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-07T17:53:50.339Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-07T17:54:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:54:14.335Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T17:54:22.179Z:USER:taskMaster.c:6582:Temperature: 26.0 C
2025-11-07T17:54:36.679Z:INFO:active_lb.c:308:SMt:(2.0 3.0 2.0)A Free:(14.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-11-07T17:55:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:56:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:56:08.167Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=234.6V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T17:56:08.183Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T17:57:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:57:38.316Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T17:57:38.707Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T17:57:50.316Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-07T17:58:02.312Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-07T17:58:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T17:58:26.312Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-07T17:59:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:00:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T18:00:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:00:50.296Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-07T18:00:50.585Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-07T18:01:02.292Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-07T18:01:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:01:14.292Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->12.8 due to current limit: Active-LoadBalancing
2025-11-07T18:01:14.824Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.3% (12.8 A)
2025-11-07T18:01:38.289Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.5 due to current limit: Active-LoadBalancing
2025-11-07T18:01:39.062Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-07T18:01:50.289Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-07T18:02:02.289Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-07T18:02:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:02:26.285Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T18:03:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:03:14.281Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T18:03:15.000Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T18:03:26.281Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->11.6 due to current limit: Active-LoadBalancing
2025-11-07T18:03:27.121Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.3% (11.6 A)
2025-11-07T18:03:38.277Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->10.6 due to current limit: Active-LoadBalancing
2025-11-07T18:03:39.238Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.6% (10.6 A)
2025-11-07T18:03:50.277Z:INFO:taskMain.c:5996:Socket #1: Active current 10.6->9.9 due to current limit: Active-LoadBalancing
2025-11-07T18:03:50.347Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.5% (9.9 A)
2025-11-07T18:04:02.277Z:INFO:taskMain.c:5996:Socket #1: Active current 9.9->9.6 due to current limit: Active-LoadBalancing
2025-11-07T18:04:02.464Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.9% (9.5 A)
2025-11-07T18:04:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:04:14.273Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->8.9 due to current limit: Active-LoadBalancing
2025-11-07T18:04:14.585Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.9% (8.9 A)
2025-11-07T18:04:26.273Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.6 due to current limit: Active-LoadBalancing
2025-11-07T18:04:26.703Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.2% (8.5 A)
2025-11-07T18:04:36.617Z:INFO:active_lb.c:308:SMt:(1.0 8.0 2.0)A Free:(15.0 8.0 14.0)A ALB:(15.0 8.6 14.0)A
2025-11-07T18:04:38.273Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.3 due to current limit: Active-LoadBalancing
2025-11-07T18:04:50.269Z:INFO:taskMain.c:5996:Socket #1: Active current 8.3->8.2 due to current limit: Active-LoadBalancing
2025-11-07T18:05:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:05:14.269Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->8.1 due to current limit: Active-LoadBalancing
2025-11-07T18:05:50.265Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->8.8 due to current limit: Active-LoadBalancing
2025-11-07T18:05:50.523Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.6% (8.8 A)
2025-11-07T18:06:02.261Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->9.3 due to current limit: Active-LoadBalancing
2025-11-07T18:06:02.644Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.4% (9.2 A)
2025-11-07T18:06:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:06:14.261Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->9.6 due to current limit: Active-LoadBalancing
2025-11-07T18:06:26.261Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->9.7 due to current limit: Active-LoadBalancing
2025-11-07T18:06:38.257Z:INFO:taskMain.c:5996:Socket #1: Active current 9.7->9.8 due to current limit: Active-LoadBalancing
2025-11-07T18:07:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:07:14.253Z:INFO:taskMain.c:5996:Socket #1: Active current 9.9->10.0 due to current limit: Active-LoadBalancing
2025-11-07T18:08:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:09:02.242Z:INFO:taskMain.c:5996:Socket #1: Active current 10.0->9.6 due to current limit: Active-LoadBalancing
2025-11-07T18:09:02.402Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.9% (9.5 A)
2025-11-07T18:09:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:09:14.242Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->9.0 due to current limit: Active-LoadBalancing
2025-11-07T18:09:14.523Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.9% (8.9 A)
2025-11-07T18:09:22.484Z:USER:taskMaster.c:6582:Temperature: 25.9 C
2025-11-07T18:09:26.242Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.6 due to current limit: Active-LoadBalancing
2025-11-07T18:09:26.640Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.2% (8.5 A)
2025-11-07T18:09:38.238Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.3 due to current limit: Active-LoadBalancing
2025-11-07T18:09:50.238Z:INFO:taskMain.c:5996:Socket #1: Active current 8.3->8.2 due to current limit: Active-LoadBalancing
2025-11-07T18:10:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:10:14.238Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->8.1 due to current limit: Active-LoadBalancing
2025-11-07T18:11:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:11:08.074Z:USER:taskMaster.c:6684:Socket #1: L1N=232.0V L2N=231.9V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T18:11:08.085Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T18:12:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:13:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:14:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:14:14.210Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->8.8 due to current limit: Active-LoadBalancing
2025-11-07T18:14:14.460Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.6% (8.8 A)
2025-11-07T18:14:26.210Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->9.3 due to current limit: Active-LoadBalancing
2025-11-07T18:14:26.578Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.4% (9.2 A)
2025-11-07T18:14:36.554Z:INFO:active_lb.c:308:SMt:(1.0 6.0 2.0)A Free:(15.0 10.0 14.0)A ALB:(14.4 9.3 14.0)A
2025-11-07T18:14:38.207Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->9.6 due to current limit: Active-LoadBalancing
2025-11-07T18:14:50.207Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->9.7 due to current limit: Active-LoadBalancing
2025-11-07T18:15:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T18:15:02.207Z:INFO:taskMain.c:5996:Socket #1: Active current 9.7->9.8 due to current limit: Active-LoadBalancing
2025-11-07T18:15:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:15:04.898Z:INFO:db_base.c:658:Erasing Transaction db sector 0x0000001d, address 0x0001d000 (1)
2025-11-07T18:15:04.910Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-07T18:15:38.203Z:INFO:taskMain.c:5996:Socket #1: Active current 9.9->10.0 due to current limit: Active-LoadBalancing
2025-11-07T18:16:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:17:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:17:50.187Z:INFO:taskMain.c:5996:Socket #1: Active current 10.0->9.6 due to current limit: Active-LoadBalancing
2025-11-07T18:17:50.578Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.9% (9.5 A)
2025-11-07T18:18:02.187Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->9.0 due to current limit: Active-LoadBalancing
2025-11-07T18:18:02.695Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.9% (8.9 A)
2025-11-07T18:18:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:18:14.187Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.6 due to current limit: Active-LoadBalancing
2025-11-07T18:18:14.816Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.2% (8.5 A)
2025-11-07T18:18:26.183Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.3 due to current limit: Active-LoadBalancing
2025-11-07T18:18:38.183Z:INFO:taskMain.c:5996:Socket #1: Active current 8.3->8.2 due to current limit: Active-LoadBalancing
2025-11-07T18:19:02.179Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->8.1 due to current limit: Active-LoadBalancing
2025-11-07T18:19:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:20:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:20:26.171Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->8.4 due to current limit: Active-LoadBalancing
2025-11-07T18:20:27.113Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.0% (8.4 A)
2025-11-07T18:20:38.171Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.6 due to current limit: Active-LoadBalancing
2025-11-07T18:20:50.167Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.8 due to current limit: Active-LoadBalancing
2025-11-07T18:21:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:21:14.167Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.9 due to current limit: Active-LoadBalancing
2025-11-07T18:22:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:22:50.156Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->9.4 due to current limit: Active-LoadBalancing
2025-11-07T18:22:50.515Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.6% (9.4 A)
2025-11-07T18:23:02.156Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->9.6 due to current limit: Active-LoadBalancing
2025-11-07T18:23:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:23:14.152Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->9.8 due to current limit: Active-LoadBalancing
2025-11-07T18:23:38.152Z:INFO:taskMain.c:5996:Socket #1: Active current 9.9->9.9 due to current limit: Active-LoadBalancing
2025-11-07T18:24:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:24:22.890Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-07T18:24:36.488Z:INFO:active_lb.c:308:SMt:(1.0 6.0 2.0)A Free:(15.0 10.0 14.0)A ALB:(14.0 10.0 14.0)A
2025-11-07T18:25:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:26:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:26:07.980Z:USER:taskMaster.c:6684:Socket #1: L1N=231.3V L2N=231.3V L3N=231.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T18:26:07.992Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T18:26:26.132Z:INFO:taskMain.c:5996:Socket #1: Active current 10.0->9.6 due to current limit: Active-LoadBalancing
2025-11-07T18:26:26.632Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.9% (9.5 A)
2025-11-07T18:26:38.132Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->9.4 due to current limit: Active-LoadBalancing
2025-11-07T18:26:50.132Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->8.8 due to current limit: Active-LoadBalancing
2025-11-07T18:26:50.871Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.6% (8.8 A)
2025-11-07T18:27:02.128Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->8.5 due to current limit: Active-LoadBalancing
2025-11-07T18:27:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:27:14.128Z:INFO:taskMain.c:5996:Socket #1: Active current 8.5->8.3 due to current limit: Active-LoadBalancing
2025-11-07T18:27:26.128Z:INFO:taskMain.c:5996:Socket #1: Active current 8.3->8.2 due to current limit: Active-LoadBalancing
2025-11-07T18:27:50.125Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->8.5 due to current limit: Active-LoadBalancing
2025-11-07T18:27:50.453Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.1% (8.5 A)
2025-11-07T18:28:02.125Z:INFO:taskMain.c:5996:Socket #1: Active current 8.5->8.7 due to current limit: Active-LoadBalancing
2025-11-07T18:28:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:28:14.121Z:INFO:taskMain.c:5996:Socket #1: Active current 8.7->8.8 due to current limit: Active-LoadBalancing
2025-11-07T18:28:38.121Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.9 due to current limit: Active-LoadBalancing
2025-11-07T18:29:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:30:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T18:30:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:31:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:31:38.101Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->9.4 due to current limit: Active-LoadBalancing
2025-11-07T18:31:38.691Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.6% (9.4 A)
2025-11-07T18:31:50.101Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->9.6 due to current limit: Active-LoadBalancing
2025-11-07T18:32:02.097Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->9.8 due to current limit: Active-LoadBalancing
2025-11-07T18:32:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:32:26.097Z:INFO:taskMain.c:5996:Socket #1: Active current 9.9->9.9 due to current limit: Active-LoadBalancing
2025-11-07T18:33:01.390Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-07T18:33:01.398Z:INFO:db_chargingprofi:26: socket 0
2025-11-07T18:33:01.406Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-07T18:33:01.414Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-07T18:33:01.421Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-07T18:33:01.433Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-07T18:33:01.441Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-07T18:33:01.453Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-07T18:33:01.460Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-07T18:33:01.468Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-07T18:33:01.476Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-07T18:33:01.484Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-07T18:33:01.492Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-07T18:33:01.500Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-07T18:33:01.507Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-07T18:33:01.519Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-07T18:33:01.527Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-07T18:33:01.535Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-07T18:33:01.542Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-07T18:33:01.554Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-07T18:33:01.558Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-07T18:33:01.566Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-07T18:33:01.578Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-07T18:33:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:34:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:34:36.425Z:INFO:active_lb.c:308:SMt:(1.0 7.0 2.0)A Free:(15.0 9.0 14.0)A ALB:(15.0 10.0 14.0)A
2025-11-07T18:34:38.082Z:INFO:taskMain.c:5996:Socket #1: Active current 10.0->9.6 due to current limit: Active-LoadBalancing
2025-11-07T18:34:38.453Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.9% (9.5 A)
2025-11-07T18:34:50.082Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->9.4 due to current limit: Active-LoadBalancing
2025-11-07T18:35:02.078Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->8.8 due to current limit: Active-LoadBalancing
2025-11-07T18:35:02.691Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.6% (8.8 A)
2025-11-07T18:35:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:35:14.078Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->8.5 due to current limit: Active-LoadBalancing
2025-11-07T18:35:26.078Z:INFO:taskMain.c:5996:Socket #1: Active current 8.5->8.3 due to current limit: Active-LoadBalancing
2025-11-07T18:35:38.074Z:INFO:taskMain.c:5996:Socket #1: Active current 8.3->8.2 due to current limit: Active-LoadBalancing
2025-11-07T18:36:02.074Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->8.5 due to current limit: Active-LoadBalancing
2025-11-07T18:36:02.273Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.1% (8.5 A)
2025-11-07T18:36:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:36:14.070Z:INFO:taskMain.c:5996:Socket #1: Active current 8.5->8.7 due to current limit: Active-LoadBalancing
2025-11-07T18:36:26.070Z:INFO:taskMain.c:5996:Socket #1: Active current 8.7->8.8 due to current limit: Active-LoadBalancing
2025-11-07T18:36:50.066Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.9 due to current limit: Active-LoadBalancing
2025-11-07T18:37:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:38:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:39:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:39:23.246Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-07T18:39:38.050Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->9.4 due to current limit: Active-LoadBalancing
2025-11-07T18:39:38.390Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.6% (9.4 A)
2025-11-07T18:39:50.050Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->9.6 due to current limit: Active-LoadBalancing
2025-11-07T18:40:02.046Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->9.8 due to current limit: Active-LoadBalancing
2025-11-07T18:40:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:40:26.046Z:INFO:taskMain.c:5996:Socket #1: Active current 9.9->9.9 due to current limit: Active-LoadBalancing
2025-11-07T18:41:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:41:07.886Z:USER:taskMaster.c:6684:Socket #1: L1N=231.7V L2N=231.7V L3N=231.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T18:41:07.898Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T18:42:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:43:02.027Z:INFO:taskMain.c:5996:Socket #1: Active current 10.0->9.6 due to current limit: Active-LoadBalancing
2025-11-07T18:43:02.390Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.9% (9.5 A)
2025-11-07T18:43:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:43:14.027Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->9.0 due to current limit: Active-LoadBalancing
2025-11-07T18:43:14.507Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.9% (8.9 A)
2025-11-07T18:43:26.027Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.6 due to current limit: Active-LoadBalancing
2025-11-07T18:43:26.625Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.2% (8.5 A)
2025-11-07T18:43:38.023Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.3 due to current limit: Active-LoadBalancing
2025-11-07T18:43:50.023Z:INFO:taskMain.c:5996:Socket #1: Active current 8.3->8.2 due to current limit: Active-LoadBalancing
2025-11-07T18:44:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:44:14.019Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->8.1 due to current limit: Active-LoadBalancing
2025-11-07T18:44:36.363Z:INFO:active_lb.c:308:SMt:(1.0 8.0 2.0)A Free:(15.0 8.0 14.0)A ALB:(15.0 8.0 14.0)A
2025-11-07T18:45:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T18:45:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:46:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:47:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:48:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:48:13.996Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->8.4 due to current limit: Active-LoadBalancing
2025-11-07T18:48:14.445Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.0% (8.4 A)
2025-11-07T18:48:25.996Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.6 due to current limit: Active-LoadBalancing
2025-11-07T18:48:37.992Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->9.2 due to current limit: Active-LoadBalancing
2025-11-07T18:48:38.683Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.3% (9.2 A)
2025-11-07T18:48:49.992Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->9.5 due to current limit: Active-LoadBalancing
2025-11-07T18:49:01.992Z:INFO:taskMain.c:5996:Socket #1: Active current 9.5->9.7 due to current limit: Active-LoadBalancing
2025-11-07T18:49:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:49:13.988Z:INFO:taskMain.c:5996:Socket #1: Active current 9.7->9.8 due to current limit: Active-LoadBalancing
2025-11-07T18:49:37.988Z:INFO:taskMain.c:5996:Socket #1: Active current 9.9->9.9 due to current limit: Active-LoadBalancing
2025-11-07T18:49:49.984Z:INFO:taskMain.c:5996:Socket #1: Active current 9.9->9.6 due to current limit: Active-LoadBalancing
2025-11-07T18:49:50.386Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.9% (9.5 A)
2025-11-07T18:50:01.984Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->9.3 due to current limit: Active-LoadBalancing
2025-11-07T18:50:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:50:13.984Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->9.6 due to current limit: Active-LoadBalancing
2025-11-07T18:50:25.980Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->9.8 due to current limit: Active-LoadBalancing
2025-11-07T18:50:49.980Z:INFO:taskMain.c:5996:Socket #1: Active current 9.9->9.9 due to current limit: Active-LoadBalancing
2025-11-07T18:51:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:51:25.976Z:INFO:taskMain.c:5996:Socket #1: Active current 10.0->9.6 due to current limit: Active-LoadBalancing
2025-11-07T18:51:26.324Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.9% (9.5 A)
2025-11-07T18:51:37.972Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->9.3 due to current limit: Active-LoadBalancing
2025-11-07T18:51:49.972Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->8.8 due to current limit: Active-LoadBalancing
2025-11-07T18:51:50.562Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.6% (8.8 A)
2025-11-07T18:52:01.972Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->8.5 due to current limit: Active-LoadBalancing
2025-11-07T18:52:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:52:13.972Z:INFO:taskMain.c:5996:Socket #1: Active current 8.5->8.3 due to current limit: Active-LoadBalancing
2025-11-07T18:52:25.968Z:INFO:taskMain.c:5996:Socket #1: Active current 8.3->8.2 due to current limit: Active-LoadBalancing
2025-11-07T18:52:49.968Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->8.1 due to current limit: Active-LoadBalancing
2025-11-07T18:53:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:54:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:54:23.652Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-07T18:54:36.300Z:INFO:active_lb.c:308:SMt:(1.0 8.0 2.0)A Free:(15.0 8.0 14.0)A ALB:(15.0 8.0 14.0)A
2025-11-07T18:55:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:56:01.945Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->7.6 due to current limit: Active-LoadBalancing
2025-11-07T18:56:02.027Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.6% (7.6 A)
2025-11-07T18:56:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:56:07.789Z:USER:taskMaster.c:6684:Socket #1: L1N=231.8V L2N=232.1V L3N=232.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T18:56:07.800Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T18:56:13.945Z:INFO:taskMain.c:5996:Socket #1: Active current 7.6->7.8 due to current limit: Active-LoadBalancing
2025-11-07T18:56:37.941Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->7.9 due to current limit: Active-LoadBalancing
2025-11-07T18:56:49.941Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->8.3 due to current limit: Active-LoadBalancing
2025-11-07T18:56:50.500Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.9% (8.3 A)
2025-11-07T18:57:01.941Z:INFO:taskMain.c:5996:Socket #1: Active current 8.3->8.6 due to current limit: Active-LoadBalancing
2025-11-07T18:57:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:57:13.937Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.8 due to current limit: Active-LoadBalancing
2025-11-07T18:57:37.937Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.9 due to current limit: Active-LoadBalancing
2025-11-07T18:58:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:59:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T18:59:49.921Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.6 due to current limit: Active-LoadBalancing
2025-11-07T18:59:50.261Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.3% (8.6 A)
2025-11-07T19:00:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T19:00:01.921Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.4 due to current limit: Active-LoadBalancing
2025-11-07T19:00:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:00:13.921Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->7.8 due to current limit: Active-LoadBalancing
2025-11-07T19:00:14.500Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.0% (7.8 A)
2025-11-07T19:00:25.917Z:INFO:taskMain.c:5996:Socket #1: Active current 7.8->7.5 due to current limit: Active-LoadBalancing
2025-11-07T19:00:26.617Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.4% (7.4 A)
2025-11-07T19:00:37.917Z:INFO:taskMain.c:5996:Socket #1: Active current 7.5->7.3 due to current limit: Active-LoadBalancing
2025-11-07T19:00:49.917Z:INFO:taskMain.c:5996:Socket #1: Active current 7.3->7.2 due to current limit: Active-LoadBalancing
2025-11-07T19:01:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:01:13.914Z:INFO:taskMain.c:5996:Socket #1: Active current 7.1->7.5 due to current limit: Active-LoadBalancing
2025-11-07T19:01:14.082Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.4% (7.4 A)
2025-11-07T19:01:25.914Z:INFO:taskMain.c:5996:Socket #1: Active current 7.5->7.7 due to current limit: Active-LoadBalancing
2025-11-07T19:01:37.910Z:INFO:taskMain.c:5996:Socket #1: Active current 7.7->7.8 due to current limit: Active-LoadBalancing
2025-11-07T19:02:01.910Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->7.9 due to current limit: Active-LoadBalancing
2025-11-07T19:02:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:02:37.906Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->7.6 due to current limit: Active-LoadBalancing
2025-11-07T19:02:37.917Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.6% (7.6 A)
2025-11-07T19:02:49.902Z:INFO:taskMain.c:5996:Socket #1: Active current 7.6->7.8 due to current limit: Active-LoadBalancing
2025-11-07T19:03:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:03:13.902Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->7.9 due to current limit: Active-LoadBalancing
2025-11-07T19:04:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:04:36.238Z:INFO:active_lb.c:308:SMt:(2.0 8.0 2.0)A Free:(14.0 8.0 14.0)A ALB:(14.0 8.0 14.0)A
2025-11-07T19:05:01.890Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->8.4 due to current limit: Active-LoadBalancing
2025-11-07T19:05:02.320Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.9% (8.3 A)
2025-11-07T19:05:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:05:13.886Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.6 due to current limit: Active-LoadBalancing
2025-11-07T19:05:25.886Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.8 due to current limit: Active-LoadBalancing
2025-11-07T19:05:49.882Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.9 due to current limit: Active-LoadBalancing
2025-11-07T19:06:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:07:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:08:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:08:25.867Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.6 due to current limit: Active-LoadBalancing
2025-11-07T19:08:26.316Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.3% (8.6 A)
2025-11-07T19:08:37.867Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.4 due to current limit: Active-LoadBalancing
2025-11-07T19:08:49.867Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.2 due to current limit: Active-LoadBalancing
2025-11-07T19:09:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:09:13.863Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->7.7 due to current limit: Active-LoadBalancing
2025-11-07T19:09:14.792Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.7% (7.6 A)
2025-11-07T19:09:24.054Z:USER:taskMaster.c:6582:Temperature: 25.0 C
2025-11-07T19:09:25.863Z:INFO:taskMain.c:5996:Socket #1: Active current 7.7->7.8 due to current limit: Active-LoadBalancing
2025-11-07T19:09:49.859Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->7.9 due to current limit: Active-LoadBalancing
2025-11-07T19:10:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:11:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:11:07.695Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=233.1V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T19:11:07.707Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T19:12:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:13:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:13:25.835Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->8.8 due to current limit: Active-LoadBalancing
2025-11-07T19:13:26.257Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.6% (8.8 A)
2025-11-07T19:13:49.832Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.9 due to current limit: Active-LoadBalancing
2025-11-07T19:14:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:14:13.832Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->9.4 due to current limit: Active-LoadBalancing
2025-11-07T19:14:14.730Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.6% (9.4 A)
2025-11-07T19:14:25.832Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->9.6 due to current limit: Active-LoadBalancing
2025-11-07T19:14:36.171Z:INFO:active_lb.c:308:SMt:(1.0 6.0 2.0)A Free:(15.0 10.0 14.0)A ALB:(15.0 9.6 14.0)A
2025-11-07T19:14:37.828Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->9.8 due to current limit: Active-LoadBalancing
2025-11-07T19:15:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T19:15:01.828Z:INFO:taskMain.c:5996:Socket #1: Active current 9.9->9.5 due to current limit: Active-LoadBalancing
2025-11-07T19:15:02.195Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.8% (9.5 A)
2025-11-07T19:15:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:15:13.824Z:INFO:taskMain.c:5996:Socket #1: Active current 9.5->9.3 due to current limit: Active-LoadBalancing
2025-11-07T19:15:25.824Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->9.2 due to current limit: Active-LoadBalancing
2025-11-07T19:15:37.824Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->9.5 due to current limit: Active-LoadBalancing
2025-11-07T19:15:49.820Z:INFO:taskMain.c:5996:Socket #1: Active current 9.5->9.7 due to current limit: Active-LoadBalancing
2025-11-07T19:16:01.820Z:INFO:taskMain.c:5996:Socket #1: Active current 9.7->9.8 due to current limit: Active-LoadBalancing
2025-11-07T19:16:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:16:04.664Z:INFO:db_base.c:658:Erasing Transaction db sector 0x0000001e, address 0x0001e000 (1)
2025-11-07T19:16:04.675Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-07T19:16:25.816Z:INFO:taskMain.c:5996:Socket #1: Active current 9.9->9.9 due to current limit: Active-LoadBalancing
2025-11-07T19:17:01.812Z:INFO:taskMain.c:5996:Socket #1: Active current 10.0->9.6 due to current limit: Active-LoadBalancing
2025-11-07T19:17:02.375Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.9% (9.5 A)
2025-11-07T19:17:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:17:13.812Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->9.0 due to current limit: Active-LoadBalancing
2025-11-07T19:17:14.492Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.9% (8.9 A)
2025-11-07T19:17:25.812Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.2 due to current limit: Active-LoadBalancing
2025-11-07T19:17:26.609Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.6% (8.2 A)
2025-11-07T19:17:37.808Z:INFO:taskMain.c:5996:Socket #1: Active current 8.2->7.7 due to current limit: Active-LoadBalancing
2025-11-07T19:17:38.730Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.8% (7.7 A)
2025-11-07T19:17:49.808Z:INFO:taskMain.c:5996:Socket #1: Active current 7.7->7.4 due to current limit: Active-LoadBalancing
2025-11-07T19:18:01.808Z:INFO:taskMain.c:5996:Socket #1: Active current 7.4->7.7 due to current limit: Active-LoadBalancing
2025-11-07T19:18:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:18:13.804Z:INFO:taskMain.c:5996:Socket #1: Active current 7.7->7.8 due to current limit: Active-LoadBalancing
2025-11-07T19:18:37.804Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->7.9 due to current limit: Active-LoadBalancing
2025-11-07T19:19:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:20:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:21:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:22:01.781Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->8.4 due to current limit: Active-LoadBalancing
2025-11-07T19:22:02.312Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.9% (8.3 A)
2025-11-07T19:22:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:22:13.781Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->9.0 due to current limit: Active-LoadBalancing
2025-11-07T19:22:14.429Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.0% (9.0 A)
2025-11-07T19:23:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:24:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:24:24.363Z:USER:taskMaster.c:6582:Temperature: 24.9 C
2025-11-07T19:24:36.109Z:INFO:active_lb.c:308:SMt:(1.0 7.0 2.0)A Free:(15.0 9.0 14.0)A ALB:(15.0 9.0 14.0)A
2025-11-07T19:25:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:25:25.808Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.2 due to current limit: Active-LoadBalancing
2025-11-07T19:25:26.308Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.6% (8.2 A)
2025-11-07T19:25:37.808Z:INFO:taskMain.c:5996:Socket #1: Active current 8.2->7.7 due to current limit: Active-LoadBalancing
2025-11-07T19:25:38.429Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.8% (7.7 A)
2025-11-07T19:25:49.808Z:INFO:taskMain.c:5996:Socket #1: Active current 7.7->7.4 due to current limit: Active-LoadBalancing
2025-11-07T19:26:01.808Z:INFO:taskMain.c:5996:Socket #1: Active current 7.4->7.3 due to current limit: Active-LoadBalancing
2025-11-07T19:26:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:26:07.601Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=234.4V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T19:26:07.613Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T19:26:13.804Z:INFO:taskMain.c:5996:Socket #1: Active current 7.3->7.6 due to current limit: Active-LoadBalancing
2025-11-07T19:26:25.804Z:INFO:taskMain.c:5996:Socket #1: Active current 7.6->7.7 due to current limit: Active-LoadBalancing
2025-11-07T19:26:37.804Z:INFO:taskMain.c:5996:Socket #1: Active current 7.7->7.8 due to current limit: Active-LoadBalancing
2025-11-07T19:26:49.800Z:INFO:taskMain.c:5996:Socket #1: Active current 7.8->9.9 due to current limit: Active-LoadBalancing
2025-11-07T19:26:50.132Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.5% (9.9 A)
2025-11-07T19:27:01.800Z:INFO:taskMain.c:5996:Socket #1: Active current 9.9->11.1 due to current limit: Active-LoadBalancing
2025-11-07T19:27:02.250Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.5% (11.1 A)
2025-11-07T19:27:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:27:13.800Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.9 due to current limit: Active-LoadBalancing
2025-11-07T19:27:14.367Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.8% (11.9 A)
2025-11-07T19:27:25.796Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->12.3 due to current limit: Active-LoadBalancing
2025-11-07T19:27:26.488Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.5% (12.3 A)
2025-11-07T19:27:37.796Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->13.0 due to current limit: Active-LoadBalancing
2025-11-07T19:27:38.605Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.6% (13.0 A)
2025-11-07T19:27:49.796Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T19:27:50.726Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T19:28:01.792Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-11-07T19:28:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:28:25.792Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.1 due to current limit: Active-LoadBalancing
2025-11-07T19:29:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:30:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T19:30:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:30:13.781Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T19:30:14.128Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T19:30:25.777Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->14.0 due to current limit: Active-LoadBalancing
2025-11-07T19:30:26.250Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.3% (14.0 A)
2025-11-07T19:31:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:32:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:33:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:33:08.910Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-07T19:33:08.921Z:INFO:db_chargingprofi:26: socket 0
2025-11-07T19:33:08.929Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-07T19:33:08.937Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-07T19:33:08.945Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-07T19:33:08.957Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-07T19:33:08.968Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-07T19:33:08.976Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-07T19:33:08.984Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-07T19:33:08.992Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-07T19:33:09.000Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-07T19:33:09.007Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-07T19:33:09.015Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-07T19:33:09.023Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-07T19:33:09.031Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-07T19:33:09.042Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-07T19:33:09.050Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-07T19:33:09.058Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-07T19:33:09.066Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-07T19:33:09.078Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-07T19:33:09.082Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-07T19:33:09.093Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-07T19:33:09.101Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-07T19:33:49.757Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.8 due to current limit: Active-LoadBalancing
2025-11-07T19:34:01.757Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.1 due to current limit: Active-LoadBalancing
2025-11-07T19:34:02.367Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.7% (13.0 A)
2025-11-07T19:34:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:34:25.753Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-11-07T19:34:26.601Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-11-07T19:34:27.644Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-07T19:34:27.656Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-07T19:34:36.046Z:INFO:active_lb.c:308:SMt:(1.0 4.0 2.0)A Free:(15.0 12.0 14.0)A ALB:(15.0 12.6 14.0)A
2025-11-07T19:34:37.753Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-11-07T19:35:01.750Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T19:35:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:36:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:37:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:38:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:38:49.726Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T19:38:50.187Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T19:39:01.722Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-07T19:39:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:39:13.722Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->14.0 due to current limit: Active-LoadBalancing
2025-11-07T19:39:14.421Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.3% (14.0 A)
2025-11-07T19:39:24.765Z:USER:taskMaster.c:6582:Temperature: 25.1 C
2025-11-07T19:40:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:41:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:41:07.503Z:USER:taskMaster.c:6684:Socket #1: L1N=231.9V L2N=231.9V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T19:41:07.515Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T19:41:49.707Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-07T19:41:49.945Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.7% (13.6 A)
2025-11-07T19:42:01.707Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.0 due to current limit: Active-LoadBalancing
2025-11-07T19:42:02.066Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.6% (13.0 A)
2025-11-07T19:42:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:42:13.703Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-11-07T19:42:14.183Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-07T19:42:25.703Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-11-07T19:42:37.703Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-11-07T19:42:49.699Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-07T19:43:01.699Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.6 due to current limit: Active-LoadBalancing
2025-11-07T19:43:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:43:13.699Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.7 due to current limit: Active-LoadBalancing
2025-11-07T19:43:25.695Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-07T19:43:49.695Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T19:44:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:44:35.984Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(14.5 13.0 14.0)A
2025-11-07T19:45:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T19:45:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:46:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:46:49.675Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T19:46:49.886Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T19:47:01.671Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-07T19:47:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:47:13.671Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-07T19:47:37.671Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->14.0 due to current limit: Active-LoadBalancing
2025-11-07T19:48:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:49:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:50:01.656Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-07T19:50:01.765Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-07T19:50:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:50:13.652Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-07T19:50:25.652Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->12.8 due to current limit: Active-LoadBalancing
2025-11-07T19:50:26.003Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.3% (12.8 A)
2025-11-07T19:50:49.648Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.5 due to current limit: Active-LoadBalancing
2025-11-07T19:50:50.238Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-07T19:51:01.648Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-07T19:51:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:51:13.648Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.6 due to current limit: Active-LoadBalancing
2025-11-07T19:51:25.644Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-11-07T19:51:49.644Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T19:52:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:53:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:54:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:54:25.070Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-07T19:54:35.917Z:INFO:active_lb.c:308:SMt:(1.0 3.0 2.0)A Free:(15.0 13.0 14.0)A ALB:(15.0 13.0 14.0)A
2025-11-07T19:55:01.625Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T19:55:01.703Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T19:55:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:55:13.621Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->14.0 due to current limit: Active-LoadBalancing
2025-11-07T19:55:13.820Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.3% (14.0 A)
2025-11-07T19:56:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:56:07.410Z:USER:taskMaster.c:6684:Socket #1: L1N=230.2V L2N=230.8V L3N=230.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T19:56:07.421Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T19:57:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:58:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:58:37.601Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-07T19:58:37.820Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.7% (13.6 A)
2025-11-07T19:58:49.597Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-07T19:59:01.597Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-11-07T19:59:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T19:59:25.593Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.1 due to current limit: Active-LoadBalancing
2025-11-07T20:00:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T20:00:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:00:25.589Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T20:00:25.878Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T20:00:37.585Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-11-07T20:00:49.585Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.5 due to current limit: Active-LoadBalancing
2025-11-07T20:01:01.585Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-11-07T20:01:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:01:13.582Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.4 due to current limit: Active-LoadBalancing
2025-11-07T20:01:25.582Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.3 due to current limit: Active-LoadBalancing
2025-11-07T20:01:37.582Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.6 due to current limit: Active-LoadBalancing
2025-11-07T20:01:49.582Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.3 due to current limit: Active-LoadBalancing
2025-11-07T20:02:01.578Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.6 due to current limit: Active-LoadBalancing
2025-11-07T20:02:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:02:13.578Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-07T20:02:37.574Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.5 due to current limit: Active-LoadBalancing
2025-11-07T20:02:49.574Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-11-07T20:03:01.574Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-11-07T20:03:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:03:13.570Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->14.0 due to current limit: Active-LoadBalancing
2025-11-07T20:04:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:04:35.855Z:INFO:active_lb.c:308:SMt:(1.0 1.0 2.0)A Free:(15.0 15.0 14.0)A ALB:(15.0 14.9 14.0)A
2025-11-07T20:05:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:06:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:06:37.550Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.8 due to current limit: Active-LoadBalancing
2025-11-07T20:06:49.546Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.5 due to current limit: Active-LoadBalancing
2025-11-07T20:06:49.636Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-07T20:07:01.546Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-11-07T20:07:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:07:13.546Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-07T20:07:37.542Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.1 due to current limit: Active-LoadBalancing
2025-11-07T20:08:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:08:13.539Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T20:08:14.468Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T20:08:25.539Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-07T20:08:37.535Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-07T20:08:49.535Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-07T20:09:01.535Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-07T20:09:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:09:13.535Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.5 due to current limit: Active-LoadBalancing
2025-11-07T20:09:25.476Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-07T20:09:25.531Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-11-07T20:09:37.531Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.6 due to current limit: Active-LoadBalancing
2025-11-07T20:09:49.531Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.7 due to current limit: Active-LoadBalancing
2025-11-07T20:10:01.527Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.4 due to current limit: Active-LoadBalancing
2025-11-07T20:10:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:10:13.527Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.7 due to current limit: Active-LoadBalancing
2025-11-07T20:10:25.527Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-11-07T20:10:37.523Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.5 due to current limit: Active-LoadBalancing
2025-11-07T20:10:37.875Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-07T20:10:49.523Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-11-07T20:11:01.523Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-11-07T20:11:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:11:07.316Z:USER:taskMaster.c:6684:Socket #1: L1N=233.3V L2N=234.4V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T20:11:07.328Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T20:11:13.519Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.5 due to current limit: Active-LoadBalancing
2025-11-07T20:11:14.230Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-07T20:11:25.519Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-11-07T20:11:37.519Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->14.2 due to current limit: Active-LoadBalancing
2025-11-07T20:11:38.468Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.6% (14.2 A)
2025-11-07T20:12:01.515Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-07T20:12:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:12:25.511Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-07T20:12:25.933Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-07T20:12:37.511Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-07T20:12:49.511Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-07T20:13:01.507Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-11-07T20:13:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:13:13.507Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T20:13:37.503Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T20:14:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:14:35.792Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-07T20:14:37.500Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T20:14:38.230Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T20:14:49.496Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-07T20:15:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T20:15:01.496Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->13.8 due to current limit: Active-LoadBalancing
2025-11-07T20:15:02.464Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-07T20:15:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:15:13.496Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.5 due to current limit: Active-LoadBalancing
2025-11-07T20:15:13.574Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-07T20:15:25.492Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-11-07T20:15:37.492Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-07T20:16:01.488Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.1 due to current limit: Active-LoadBalancing
2025-11-07T20:16:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:17:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:17:04.128Z:INFO:db_base.c:658:Erasing Transaction db sector 0x0000001f, address 0x0001f000 (1)
2025-11-07T20:17:04.140Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-07T20:17:13.484Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T20:17:13.753Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T20:17:25.480Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-11-07T20:17:49.480Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.5 due to current limit: Active-LoadBalancing
2025-11-07T20:18:01.476Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-11-07T20:18:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:18:13.476Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.4 due to current limit: Active-LoadBalancing
2025-11-07T20:18:25.476Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-07T20:18:37.472Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-07T20:18:49.472Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-11-07T20:19:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:19:13.468Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.1 due to current limit: Active-LoadBalancing
2025-11-07T20:20:01.464Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.8 due to current limit: Active-LoadBalancing
2025-11-07T20:20:02.406Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-07T20:20:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:20:25.460Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->14.3 due to current limit: Active-LoadBalancing
2025-11-07T20:20:25.632Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.8% (14.3 A)
2025-11-07T20:20:37.460Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-07T20:20:49.460Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T20:21:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:21:13.457Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T20:21:25.457Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.5 due to current limit: Active-LoadBalancing
2025-11-07T20:21:26.226Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-07T20:21:37.453Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T20:21:49.453Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T20:22:01.453Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.5 due to current limit: Active-LoadBalancing
2025-11-07T20:22:01.570Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-07T20:22:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:22:13.449Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T20:22:25.449Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T20:22:49.445Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T20:23:01.445Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.6 due to current limit: Active-LoadBalancing
2025-11-07T20:23:02.164Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-07T20:23:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:23:13.445Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->13.9 due to current limit: Active-LoadBalancing
2025-11-07T20:23:14.285Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.2% (13.9 A)
2025-11-07T20:23:25.441Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.6 due to current limit: Active-LoadBalancing
2025-11-07T20:23:26.402Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-07T20:23:37.441Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.3 due to current limit: Active-LoadBalancing
2025-11-07T20:23:49.441Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-07T20:24:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:24:13.437Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.1 due to current limit: Active-LoadBalancing
2025-11-07T20:24:25.882Z:USER:taskMaster.c:6582:Temperature: 24.4 C
2025-11-07T20:24:35.730Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-07T20:24:37.437Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T20:24:38.105Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T20:24:49.433Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.7 due to current limit: Active-LoadBalancing
2025-11-07T20:25:01.433Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.4 due to current limit: Active-LoadBalancing
2025-11-07T20:25:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:25:13.433Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-07T20:25:25.429Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-07T20:25:49.429Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-07T20:26:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:26:07.218Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.2V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T20:26:07.234Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T20:26:37.421Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-07T20:26:38.273Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-07T20:26:49.421Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-07T20:27:01.421Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-07T20:27:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:27:13.417Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-07T20:27:37.417Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.5 due to current limit: Active-LoadBalancing
2025-11-07T20:27:37.855Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.5% (13.5 A)
2025-11-07T20:27:49.414Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-11-07T20:28:01.414Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-07T20:28:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:28:13.414Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.5 due to current limit: Active-LoadBalancing
2025-11-07T20:28:14.210Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.5% (13.5 A)
2025-11-07T20:28:25.410Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-11-07T20:28:37.410Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->14.2 due to current limit: Active-LoadBalancing
2025-11-07T20:28:37.441Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.7% (14.2 A)
2025-11-07T20:28:49.410Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-07T20:29:01.406Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T20:29:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:29:13.406Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T20:29:37.402Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T20:30:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T20:30:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:31:01.394Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T20:31:01.855Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T20:31:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:31:13.394Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-07T20:31:25.394Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->13.8 due to current limit: Active-LoadBalancing
2025-11-07T20:31:26.093Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-07T20:31:37.390Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.5 due to current limit: Active-LoadBalancing
2025-11-07T20:31:38.210Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-07T20:31:49.390Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-11-07T20:32:01.390Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-07T20:32:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:32:25.386Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.1 due to current limit: Active-LoadBalancing
2025-11-07T20:33:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:33:16.429Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-07T20:33:16.437Z:INFO:db_chargingprofi:26: socket 0
2025-11-07T20:33:16.445Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-07T20:33:16.453Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-07T20:33:16.460Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-07T20:33:16.472Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-07T20:33:16.480Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-07T20:33:16.488Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-07T20:33:16.500Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-07T20:33:16.507Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-07T20:33:16.515Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-07T20:33:16.523Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-07T20:33:16.531Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-07T20:33:16.539Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-07T20:33:16.550Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-07T20:33:16.562Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-07T20:33:16.570Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-07T20:33:16.578Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-07T20:33:16.585Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-07T20:33:16.597Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-07T20:33:16.605Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-07T20:33:16.613Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-07T20:33:16.621Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-07T20:34:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:34:35.667Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 15.0)A
2025-11-07T20:35:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:36:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:36:13.363Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T20:36:13.914Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T20:36:25.359Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->14.0 due to current limit: Active-LoadBalancing
2025-11-07T20:36:26.031Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.4% (14.0 A)
2025-11-07T20:37:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:37:13.355Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-07T20:37:13.496Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-07T20:37:25.355Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-07T20:37:37.351Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T20:38:01.351Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T20:38:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:39:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:39:25.343Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T20:39:25.792Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T20:39:26.234Z:USER:taskMaster.c:6582:Temperature: 24.4 C
2025-11-07T20:39:37.339Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.0 due to current limit: Active-LoadBalancing
2025-11-07T20:39:37.910Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.2% (13.9 A)
2025-11-07T20:39:49.339Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-07T20:39:50.031Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-07T20:40:01.339Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.3 due to current limit: Active-LoadBalancing
2025-11-07T20:40:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:40:13.335Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-07T20:40:37.335Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.1 due to current limit: Active-LoadBalancing
2025-11-07T20:41:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:41:07.125Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=234.7V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T20:41:07.136Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T20:42:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:42:49.320Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.4 due to current limit: Active-LoadBalancing
2025-11-07T20:42:49.789Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-07T20:43:01.320Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-07T20:43:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:43:13.316Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.8 due to current limit: Active-LoadBalancing
2025-11-07T20:43:37.316Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.5 due to current limit: Active-LoadBalancing
2025-11-07T20:43:38.265Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.5% (13.5 A)
2025-11-07T20:43:49.312Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-11-07T20:44:01.312Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-11-07T20:44:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:44:13.312Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.5 due to current limit: Active-LoadBalancing
2025-11-07T20:44:13.613Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-07T20:44:25.308Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-11-07T20:44:35.601Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.7 15.0)A
2025-11-07T20:44:37.308Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->14.2 due to current limit: Active-LoadBalancing
2025-11-07T20:44:37.847Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.6% (14.2 A)
2025-11-07T20:44:49.308Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-07T20:44:49.968Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-07T20:45:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T20:45:01.304Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-07T20:45:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:45:13.304Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-07T20:45:37.300Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-07T20:46:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:46:13.300Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-07T20:46:13.789Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-07T20:46:25.296Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-07T20:46:37.296Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T20:47:01.292Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T20:47:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:47:37.289Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T20:47:37.609Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T20:47:49.289Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-07T20:48:01.289Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->13.8 due to current limit: Active-LoadBalancing
2025-11-07T20:48:01.847Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-07T20:48:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:48:13.285Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.5 due to current limit: Active-LoadBalancing
2025-11-07T20:48:13.964Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-07T20:48:25.285Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-11-07T20:48:37.285Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-07T20:49:01.281Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.5 due to current limit: Active-LoadBalancing
2025-11-07T20:49:01.429Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-07T20:49:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:49:13.281Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-11-07T20:49:25.277Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-11-07T20:49:49.324Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-07T20:50:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:51:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:52:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:53:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:54:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:54:26.640Z:USER:taskMaster.c:6582:Temperature: 24.5 C
2025-11-07T20:54:35.539Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 14.0 15.0)A
2025-11-07T20:55:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:56:01.335Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-07T20:56:01.546Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-07T20:56:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:56:07.031Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=235.4V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T20:56:07.042Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T20:56:13.335Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-07T20:56:25.335Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T20:56:37.332Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-07T20:56:49.332Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-07T20:57:01.332Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-07T20:57:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:57:25.328Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-07T20:58:01.324Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-07T20:58:01.722Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-07T20:58:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:58:13.324Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-07T20:58:25.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T20:58:49.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T20:59:01.316Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.6 due to current limit: Active-LoadBalancing
2025-11-07T20:59:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T20:59:13.316Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-07T20:59:25.316Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->13.8 due to current limit: Active-LoadBalancing
2025-11-07T20:59:25.546Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-07T20:59:37.312Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.5 due to current limit: Active-LoadBalancing
2025-11-07T20:59:37.664Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-07T20:59:49.312Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.3 due to current limit: Active-LoadBalancing
2025-11-07T21:00:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T21:00:01.312Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-07T21:00:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:00:25.308Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.5 due to current limit: Active-LoadBalancing
2025-11-07T21:00:26.140Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-07T21:00:37.308Z:INFO:taskMain.c:5996:Socket #1: Active current 13.5->13.7 due to current limit: Active-LoadBalancing
2025-11-07T21:00:49.304Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-11-07T21:01:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:01:13.304Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-07T21:02:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:03:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:04:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:04:35.476Z:INFO:active_lb.c:308:SMt:(2.0 2.0 1.0)A Free:(14.0 14.0 15.0)A ALB:(14.0 14.0 15.0)A
2025-11-07T21:05:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:05:25.277Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-07T21:05:26.078Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-07T21:05:37.277Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-07T21:05:49.273Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T21:06:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:06:13.273Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T21:07:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:07:49.261Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T21:07:49.480Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T21:08:01.261Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.0 due to current limit: Active-LoadBalancing
2025-11-07T21:08:01.601Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.2% (13.9 A)
2025-11-07T21:08:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:08:13.257Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-07T21:08:13.718Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-07T21:08:25.257Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.3 due to current limit: Active-LoadBalancing
2025-11-07T21:08:37.257Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-07T21:09:01.253Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.1 due to current limit: Active-LoadBalancing
2025-11-07T21:09:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:09:13.253Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.4 due to current limit: Active-LoadBalancing
2025-11-07T21:09:13.304Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.4% (13.4 A)
2025-11-07T21:09:25.250Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.7 due to current limit: Active-LoadBalancing
2025-11-07T21:09:26.945Z:USER:taskMaster.c:6582:Temperature: 24.1 C
2025-11-07T21:09:37.250Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.8 due to current limit: Active-LoadBalancing
2025-11-07T21:10:01.250Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.9 due to current limit: Active-LoadBalancing
2025-11-07T21:10:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:11:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:11:06.933Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=232.2V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T21:11:06.949Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T21:12:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:12:49.230Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.6 due to current limit: Active-LoadBalancing
2025-11-07T21:12:49.421Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-07T21:13:01.230Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-07T21:13:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:13:13.226Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->12.8 due to current limit: Active-LoadBalancing
2025-11-07T21:13:13.656Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.3% (12.8 A)
2025-11-07T21:13:25.226Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.5 due to current limit: Active-LoadBalancing
2025-11-07T21:13:37.226Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-07T21:13:49.222Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.2 due to current limit: Active-LoadBalancing
2025-11-07T21:14:01.222Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.5 due to current limit: Active-LoadBalancing
2025-11-07T21:14:02.132Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-07T21:14:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:14:13.222Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-07T21:14:25.218Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.8 due to current limit: Active-LoadBalancing
2025-11-07T21:14:35.414Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 12.8 15.0)A
2025-11-07T21:14:49.218Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T21:15:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T21:15:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:16:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:17:01.203Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-11-07T21:17:01.882Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-07T21:17:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:17:13.203Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-11-07T21:17:25.203Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->11.8 due to current limit: Active-LoadBalancing
2025-11-07T21:17:26.121Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.6% (11.8 A)
2025-11-07T21:17:37.199Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.5 due to current limit: Active-LoadBalancing
2025-11-07T21:17:49.199Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-07T21:18:01.199Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-07T21:18:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:18:04.890Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000020, address 0x00020000 (1)
2025-11-07T21:18:04.902Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-07T21:18:25.195Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.5 due to current limit: Active-LoadBalancing
2025-11-07T21:18:25.703Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.1% (11.5 A)
2025-11-07T21:18:37.195Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-07T21:18:49.191Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.8 due to current limit: Active-LoadBalancing
2025-11-07T21:19:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:19:13.191Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.9 due to current limit: Active-LoadBalancing
2025-11-07T21:20:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:21:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:22:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:23:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:24:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:24:27.351Z:USER:taskMaster.c:6582:Temperature: 24.1 C
2025-11-07T21:24:35.351Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 12.0 15.0)A
2025-11-07T21:25:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:26:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:26:06.839Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=233.0V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T21:26:06.851Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T21:26:37.144Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-11-07T21:26:37.523Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-11-07T21:26:49.140Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-11-07T21:27:01.140Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-11-07T21:27:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:27:25.136Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T21:28:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:29:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:29:37.125Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-11-07T21:29:37.285Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-07T21:29:49.121Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-11-07T21:30:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T21:30:01.121Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->11.8 due to current limit: Active-LoadBalancing
2025-11-07T21:30:01.519Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.6% (11.8 A)
2025-11-07T21:30:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:30:13.121Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.5 due to current limit: Active-LoadBalancing
2025-11-07T21:30:25.117Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-07T21:30:37.117Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-07T21:31:01.113Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.5 due to current limit: Active-LoadBalancing
2025-11-07T21:31:02.113Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.1% (11.5 A)
2025-11-07T21:31:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:31:13.113Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-07T21:31:25.113Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.8 due to current limit: Active-LoadBalancing
2025-11-07T21:31:49.109Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.9 due to current limit: Active-LoadBalancing
2025-11-07T21:32:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:33:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:33:23.949Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-07T21:33:23.957Z:INFO:db_chargingprofi:26: socket 0
2025-11-07T21:33:23.964Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-07T21:33:23.972Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-07T21:33:23.980Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-07T21:33:23.988Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-07T21:33:24.000Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-07T21:33:24.007Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-07T21:33:24.019Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-07T21:33:24.027Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-07T21:33:24.035Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-07T21:33:24.042Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-07T21:33:24.050Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-07T21:33:24.058Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-07T21:33:24.066Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-07T21:33:24.074Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-07T21:33:24.082Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-07T21:33:24.093Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-07T21:33:24.101Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-07T21:33:24.109Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-07T21:33:24.117Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-07T21:33:24.125Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-07T21:33:24.132Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-07T21:34:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:34:21.445Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-07T21:34:21.714Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-07T21:34:26.886Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-07T21:34:26.898Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-07T21:34:35.285Z:INFO:active_lb.c:308:SMt:(2.0 4.0 1.0)A Free:(14.0 12.0 15.0)A ALB:(14.4 12.0 14.8)A
2025-11-07T21:34:35.296Z:INFO:comFaults.c:482:Reset fault status
2025-11-07T21:35:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:35:13.089Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-11-07T21:35:13.578Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-11-07T21:35:25.085Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-11-07T21:35:37.085Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-11-07T21:36:01.082Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T21:36:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:37:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:38:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:38:13.121Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-11-07T21:38:13.339Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-07T21:38:25.117Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-11-07T21:38:37.117Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->11.8 due to current limit: Active-LoadBalancing
2025-11-07T21:38:37.578Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.6% (11.8 A)
2025-11-07T21:38:49.117Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.5 due to current limit: Active-LoadBalancing
2025-11-07T21:39:01.113Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-07T21:39:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:39:13.113Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-07T21:39:27.707Z:USER:taskMaster.c:6582:Temperature: 24.0 C
2025-11-07T21:39:37.109Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.5 due to current limit: Active-LoadBalancing
2025-11-07T21:39:37.160Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.1% (11.5 A)
2025-11-07T21:39:49.109Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-07T21:40:01.109Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.8 due to current limit: Active-LoadBalancing
2025-11-07T21:40:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:40:25.105Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.9 due to current limit: Active-LoadBalancing
2025-11-07T21:41:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:41:06.746Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.1V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T21:41:06.757Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T21:42:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:43:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:44:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:44:35.222Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 12.0 15.0)A
2025-11-07T21:45:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T21:45:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:46:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:47:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:48:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:49:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:50:01.042Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-11-07T21:50:01.273Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-11-07T21:50:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:50:13.042Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-11-07T21:50:25.042Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-11-07T21:50:49.039Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T21:51:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:52:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:53:01.027Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.6 due to current limit: Active-LoadBalancing
2025-11-07T21:53:01.039Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-07T21:53:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:53:13.023Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-11-07T21:53:25.023Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->11.8 due to current limit: Active-LoadBalancing
2025-11-07T21:53:25.273Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.6% (11.8 A)
2025-11-07T21:53:37.023Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.5 due to current limit: Active-LoadBalancing
2025-11-07T21:53:49.019Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-07T21:54:01.019Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-07T21:54:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:54:25.015Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.5 due to current limit: Active-LoadBalancing
2025-11-07T21:54:25.867Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.1% (11.5 A)
2025-11-07T21:54:28.058Z:USER:taskMaster.c:6582:Temperature: 23.9 C
2025-11-07T21:54:35.160Z:INFO:active_lb.c:308:SMt:(1.0 4.0 1.0)A Free:(15.0 12.0 15.0)A ALB:(15.0 11.5 15.0)A
2025-11-07T21:54:37.015Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-07T21:54:49.015Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.8 due to current limit: Active-LoadBalancing
2025-11-07T21:55:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:55:13.011Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.9 due to current limit: Active-LoadBalancing
2025-11-07T21:56:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:56:06.648Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=233.8V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T21:56:06.660Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T21:57:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:58:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:58:36.988Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-11-07T21:58:37.328Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-11-07T21:58:48.988Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-11-07T21:59:00.988Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-11-07T21:59:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T21:59:24.984Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.9 due to current limit: Active-LoadBalancing
2025-11-07T22:00:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T22:00:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:01:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:02:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:02:26.574Z:INFO:taskMain.c:6494:Socket #1: CPhigh 7.6 V
2025-11-07T22:02:26.609Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-07T22:02:26.617Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-07T22:02:26.628Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=234.1V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:02:26.640Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=1.1mA
2025-11-07T22:02:26.652Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-07T22:02:26.660Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-07T22:02:26.667Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-07T22:02:27.585Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-07T22:02:27.605Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-07T22:02:36.964Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->15.9 due to current limit: ChargingProfile
2025-11-07T22:02:37.007Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-07T22:02:37.703Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-07T22:02:56.656Z:USER:taskMaster.c:6684:Socket #1: L1N=232.7V L2N=232.9V L3N=232.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:02:56.667Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-11-07T22:03:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:03:12.960Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.0 due to current limit: Active-LoadBalancing
2025-11-07T22:03:12.972Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->24.9)
2025-11-07T22:03:13.003Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-07T22:03:13.050Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.9% (14.9 A)
2025-11-07T22:03:24.960Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.0 due to current limit: Active-LoadBalancing
2025-11-07T22:03:24.972Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->23.3)
2025-11-07T22:03:25.167Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.3% (14.0 A)
2025-11-07T22:03:26.589Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-07T22:03:26.652Z:USER:taskMaster.c:6684:Socket #1: L1N=233.3V L2N=233.2V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:03:26.667Z:USER:taskMaster.c:6720:Socket #1: I1=14.5A I2=14.6A I3=14.6A P=10.2kW Idc=0.7mA
2025-11-07T22:03:36.957Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->13.1 due to current limit: Active-LoadBalancing
2025-11-07T22:03:36.972Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.3->21.7)
2025-11-07T22:03:37.289Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.7% (13.0 A)
2025-11-07T22:03:48.957Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.5 due to current limit: Active-LoadBalancing
2025-11-07T22:03:48.968Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.7->20.8)
2025-11-07T22:03:49.406Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-07T22:03:56.648Z:USER:taskMaster.c:6684:Socket #1: L1N=233.2V L2N=233.3V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:03:56.664Z:USER:taskMaster.c:6720:Socket #1: I1=12.1A I2=12.1A I3=12.1A P=8.5kW Idc=0.7mA
2025-11-07T22:04:00.957Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.4 due to current limit: Active-LoadBalancing
2025-11-07T22:04:00.968Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.8->20.5)
2025-11-07T22:04:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:04:12.953Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-11-07T22:04:24.953Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.9 due to current limit: Active-LoadBalancing
2025-11-07T22:04:26.648Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=233.6V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:04:26.660Z:USER:taskMaster.c:6720:Socket #1: I1=12.3A I2=12.3A I3=12.3A P=8.6kW Idc=0.7mA
2025-11-07T22:04:35.097Z:INFO:active_lb.c:308:SMt:(12.0 15.0 13.0)A Free:(4.0 1.0 3.0)A ALB:(15.8 12.9 15.1)A
2025-11-07T22:04:36.953Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.1 due to current limit: Active-LoadBalancing
2025-11-07T22:04:48.949Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.9 due to current limit: Active-LoadBalancing
2025-11-07T22:04:48.964Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.8->21.5)
2025-11-07T22:04:56.644Z:USER:taskMaster.c:6684:Socket #1: L1N=233.2V L2N=233.5V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:04:56.656Z:USER:taskMaster.c:6720:Socket #1: I1=12.6A I2=12.6A I3=12.6A P=8.8kW Idc=0.7mA
2025-11-07T22:05:00.949Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.8 due to current limit: Active-LoadBalancing
2025-11-07T22:05:00.960Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.5->21.3)
2025-11-07T22:05:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:05:12.949Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.7 due to current limit: Active-LoadBalancing
2025-11-07T22:05:12.960Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.3->21.0)
2025-11-07T22:05:24.945Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.5 due to current limit: Active-LoadBalancing
2025-11-07T22:05:24.960Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.0->20.8)
2025-11-07T22:05:26.640Z:USER:taskMaster.c:6684:Socket #1: L1N=233.2V L2N=233.4V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:05:26.652Z:USER:taskMaster.c:6720:Socket #1: I1=12.3A I2=12.3A I3=12.3A P=8.6kW Idc=0.7mA
2025-11-07T22:05:36.945Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.8 due to current limit: Active-LoadBalancing
2025-11-07T22:05:48.945Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->13.0 due to current limit: Active-LoadBalancing
2025-11-07T22:05:56.636Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=233.3V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:05:56.648Z:USER:taskMaster.c:6720:Socket #1: I1=12.6A I2=12.7A I3=12.6A P=8.8kW Idc=0.7mA
2025-11-07T22:06:00.941Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.9 due to current limit: Active-LoadBalancing
2025-11-07T22:06:00.957Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.7->21.4)
2025-11-07T22:06:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:06:12.941Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.7 due to current limit: Active-LoadBalancing
2025-11-07T22:06:12.953Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.4->21.1)
2025-11-07T22:06:24.941Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.5 due to current limit: Active-LoadBalancing
2025-11-07T22:06:24.953Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.1->20.9)
2025-11-07T22:06:26.632Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=233.6V L3N=233.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:06:26.648Z:USER:taskMaster.c:6720:Socket #1: I1=12.2A I2=12.3A I3=12.3A P=8.5kW Idc=0.7mA
2025-11-07T22:06:36.937Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.8 due to current limit: Active-LoadBalancing
2025-11-07T22:06:48.937Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->13.0 due to current limit: Active-LoadBalancing
2025-11-07T22:06:56.632Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=233.8V L3N=233.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:06:56.644Z:USER:taskMaster.c:6720:Socket #1: I1=12.6A I2=12.7A I3=12.6A P=8.8kW Idc=0.7mA
2025-11-07T22:07:00.937Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.9 due to current limit: Active-LoadBalancing
2025-11-07T22:07:00.949Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.7->21.4)
2025-11-07T22:07:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:07:12.933Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.7 due to current limit: Active-LoadBalancing
2025-11-07T22:07:12.949Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.4->21.1)
2025-11-07T22:07:24.933Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.6 due to current limit: Active-LoadBalancing
2025-11-07T22:07:24.945Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.1->20.9)
2025-11-07T22:07:26.628Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=233.8V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:07:26.640Z:USER:taskMaster.c:6720:Socket #1: I1=12.3A I2=12.3A I3=12.3A P=8.5kW Idc=0.7mA
2025-11-07T22:07:26.652Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-07T22:07:36.933Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-11-07T22:07:48.929Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->13.0 due to current limit: Active-LoadBalancing
2025-11-07T22:08:00.929Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.9 due to current limit: Active-LoadBalancing
2025-11-07T22:08:00.941Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.7->21.4)
2025-11-07T22:08:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:08:12.929Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.7 due to current limit: Active-LoadBalancing
2025-11-07T22:08:12.941Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.4->21.2)
2025-11-07T22:08:24.929Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.6 due to current limit: Active-LoadBalancing
2025-11-07T22:08:24.941Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.2->21.0)
2025-11-07T22:08:36.925Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.5 due to current limit: Active-LoadBalancing
2025-11-07T22:08:36.937Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.0->20.8)
2025-11-07T22:08:48.925Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.3 due to current limit: Active-LoadBalancing
2025-11-07T22:08:48.937Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.8->20.5)
2025-11-07T22:09:00.925Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.6 due to current limit: Active-LoadBalancing
2025-11-07T22:09:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:09:12.921Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-11-07T22:09:24.921Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->13.0 due to current limit: Active-LoadBalancing
2025-11-07T22:09:28.464Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-07T22:09:36.921Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.9 due to current limit: Active-LoadBalancing
2025-11-07T22:09:36.933Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.7->21.4)
2025-11-07T22:09:48.917Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.7 due to current limit: Active-LoadBalancing
2025-11-07T22:09:48.929Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.4->21.2)
2025-11-07T22:10:00.917Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.6 due to current limit: Active-LoadBalancing
2025-11-07T22:10:00.929Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.2->20.9)
2025-11-07T22:10:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:10:12.917Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.4 due to current limit: Active-LoadBalancing
2025-11-07T22:10:12.929Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.9->20.7)
2025-11-07T22:10:24.914Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.7 due to current limit: Active-LoadBalancing
2025-11-07T22:10:36.914Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->13.0 due to current limit: Active-LoadBalancing
2025-11-07T22:10:48.914Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.2 due to current limit: Active-LoadBalancing
2025-11-07T22:11:00.910Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.1 due to current limit: Active-LoadBalancing
2025-11-07T22:11:00.925Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.0->21.8)
2025-11-07T22:11:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:11:12.910Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.9 due to current limit: Active-LoadBalancing
2025-11-07T22:11:12.921Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.8->21.5)
2025-11-07T22:11:24.910Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.8 due to current limit: Active-LoadBalancing
2025-11-07T22:11:24.921Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.5->21.3)
2025-11-07T22:11:36.906Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.6 due to current limit: Active-LoadBalancing
2025-11-07T22:11:36.921Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.3->21.0)
2025-11-07T22:11:48.906Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.5 due to current limit: Active-LoadBalancing
2025-11-07T22:11:48.917Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.0->20.8)
2025-11-07T22:12:00.906Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.4 due to current limit: Active-LoadBalancing
2025-11-07T22:12:00.917Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.8->20.5)
2025-11-07T22:12:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:12:12.902Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.6 due to current limit: Active-LoadBalancing
2025-11-07T22:12:24.902Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.9 due to current limit: Active-LoadBalancing
2025-11-07T22:12:36.902Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.8 due to current limit: Active-LoadBalancing
2025-11-07T22:12:36.914Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.5->21.2)
2025-11-07T22:12:48.898Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.6 due to current limit: Active-LoadBalancing
2025-11-07T22:12:48.914Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.2->21.0)
2025-11-07T22:13:00.898Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.5 due to current limit: Active-LoadBalancing
2025-11-07T22:13:00.910Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.0->20.8)
2025-11-07T22:13:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:13:12.898Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-07T22:13:24.894Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->13.0 due to current limit: Active-LoadBalancing
2025-11-07T22:13:36.894Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->12.8 due to current limit: Active-LoadBalancing
2025-11-07T22:13:36.906Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.6->21.3)
2025-11-07T22:13:48.894Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.6 due to current limit: Active-LoadBalancing
2025-11-07T22:13:48.906Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.3->21.0)
2025-11-07T22:14:00.890Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.5 due to current limit: Active-LoadBalancing
2025-11-07T22:14:00.906Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.0->20.8)
2025-11-07T22:14:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:14:12.890Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.7 due to current limit: Active-LoadBalancing
2025-11-07T22:14:24.890Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->13.0 due to current limit: Active-LoadBalancing
2025-11-07T22:14:35.031Z:INFO:active_lb.c:308:SMt:(12.0 15.0 13.0)A Free:(4.0 1.0 3.0)A ALB:(15.3 13.0 15.2)A
2025-11-07T22:14:36.886Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.2 due to current limit: Active-LoadBalancing
2025-11-07T22:14:48.886Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.1 due to current limit: Active-LoadBalancing
2025-11-07T22:14:48.898Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.0->21.8)
2025-11-07T22:15:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T22:15:00.886Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.9 due to current limit: Active-LoadBalancing
2025-11-07T22:15:00.898Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.8->21.5)
2025-11-07T22:15:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:15:12.882Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.8 due to current limit: Active-LoadBalancing
2025-11-07T22:15:12.898Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.5->21.3)
2025-11-07T22:15:17.378Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-07T22:15:17.386Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-07T22:15:17.398Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-07T22:15:17.406Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-07T22:15:18.164Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-07T22:15:18.382Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-07T22:15:24.882Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->7.7 due to current limit: Active-LoadBalancing
2025-11-07T22:15:25.453Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.7% (7.6 A)
2025-11-07T22:15:36.882Z:INFO:taskMain.c:5996:Socket #1: Active current 7.7->9.8 due to current limit: Active-LoadBalancing
2025-11-07T22:15:37.570Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.3% (9.8 A)
2025-11-07T22:15:48.882Z:INFO:taskMain.c:5996:Socket #1: Active current 9.8->11.1 due to current limit: Active-LoadBalancing
2025-11-07T22:15:49.691Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.4% (11.0 A)
2025-11-07T22:16:00.878Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.9 due to current limit: Active-LoadBalancing
2025-11-07T22:16:01.808Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.7% (11.8 A)
2025-11-07T22:16:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:16:36.875Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->12.0 due to current limit: Active-LoadBalancing
2025-11-07T22:16:48.875Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.4 due to current limit: Active-LoadBalancing
2025-11-07T22:16:49.273Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.6% (12.4 A)
2025-11-07T22:17:00.875Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.2 due to current limit: Active-LoadBalancing
2025-11-07T22:17:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:17:14.265Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-07T22:17:14.273Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-07T22:17:14.285Z:USER:taskMaster.c:6684:Socket #1: L1N=233.2V L2N=233.4V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:17:14.296Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T22:17:14.308Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-07T22:17:14.316Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-07T22:17:14.324Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-07T22:17:14.523Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-07T22:17:15.273Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-07T22:17:18.390Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->15.0 due to current limit: Active-LoadBalancing
2025-11-07T22:17:19.312Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.9% (14.9 A)
2025-11-07T22:17:23.390Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->12.1 due to current limit: Active-LoadBalancing
2025-11-07T22:17:23.402Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->20.2)
2025-11-07T22:17:24.359Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.2% (12.1 A)
2025-11-07T22:17:24.914Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-07T22:17:28.390Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->15.9 due to current limit: ChargingProfile
2025-11-07T22:17:28.402Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-07T22:17:44.312Z:USER:taskMaster.c:6684:Socket #1: L1N=231.7V L2N=232.0V L3N=231.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:17:44.324Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.6A I3=15.6A P=10.8kW Idc=0.7mA
2025-11-07T22:17:48.867Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->14.7 due to current limit: Active-LoadBalancing
2025-11-07T22:17:48.882Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->24.4)
2025-11-07T22:17:48.910Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-07T22:17:49.609Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.4% (14.6 A)
2025-11-07T22:18:00.867Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->13.3 due to current limit: Active-LoadBalancing
2025-11-07T22:18:00.878Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->22.1)
2025-11-07T22:18:01.726Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.1% (13.3 A)
2025-11-07T22:18:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:18:12.867Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->12.7 due to current limit: Active-LoadBalancing
2025-11-07T22:18:12.878Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.1->21.2)
2025-11-07T22:18:13.843Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.2% (12.7 A)
2025-11-07T22:18:14.253Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-07T22:18:14.308Z:USER:taskMaster.c:6684:Socket #1: L1N=232.0V L2N=232.1V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:18:14.320Z:USER:taskMaster.c:6720:Socket #1: I1=12.9A I2=12.9A I3=12.9A P=9.0kW Idc=0.7mA
2025-11-07T22:18:24.863Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.2 due to current limit: Active-LoadBalancing
2025-11-07T22:18:24.878Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.2->20.3)
2025-11-07T22:18:24.953Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.3% (12.2 A)
2025-11-07T22:18:36.863Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->12.0 due to current limit: Active-LoadBalancing
2025-11-07T22:18:36.875Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.3->20.0)
2025-11-07T22:18:44.304Z:USER:taskMaster.c:6684:Socket #1: L1N=232.3V L2N=232.5V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:18:44.320Z:USER:taskMaster.c:6720:Socket #1: I1=11.7A I2=11.7A I3=11.7A P=8.2kW Idc=0.7mA
2025-11-07T22:18:48.863Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.3 due to current limit: Active-LoadBalancing
2025-11-07T22:19:00.859Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.6 due to current limit: Active-LoadBalancing
2025-11-07T22:19:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:19:04.804Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000021, address 0x00021000 (1)
2025-11-07T22:19:04.816Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-07T22:19:12.859Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.8 due to current limit: Active-LoadBalancing
2025-11-07T22:19:14.304Z:USER:taskMaster.c:6684:Socket #1: L1N=232.0V L2N=232.3V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:19:14.316Z:USER:taskMaster.c:6720:Socket #1: I1=12.2A I2=12.2A I3=12.2A P=8.5kW Idc=0.7mA
2025-11-07T22:19:24.859Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->13.1 due to current limit: Active-LoadBalancing
2025-11-07T22:19:36.855Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.4 due to current limit: Active-LoadBalancing
2025-11-07T22:19:44.300Z:USER:taskMaster.c:6684:Socket #1: L1N=231.8V L2N=232.1V L3N=231.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:19:44.312Z:USER:taskMaster.c:6720:Socket #1: I1=13.0A I2=13.0A I3=12.9A P=9.0kW Idc=0.7mA
2025-11-07T22:19:48.855Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.2 due to current limit: Active-LoadBalancing
2025-11-07T22:19:48.867Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.2->22.0)
2025-11-07T22:20:00.855Z:INFO:taskMain.c:5996:Socket #1: Active current 13.2->13.1 due to current limit: Active-LoadBalancing
2025-11-07T22:20:00.867Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.0->21.8)
2025-11-07T22:20:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:20:12.851Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->12.9 due to current limit: Active-LoadBalancing
2025-11-07T22:20:12.867Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.8->21.5)
2025-11-07T22:20:14.296Z:USER:taskMaster.c:6684:Socket #1: L1N=231.5V L2N=232.2V L3N=231.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:20:14.308Z:USER:taskMaster.c:6720:Socket #1: I1=12.7A I2=12.7A I3=12.7A P=8.8kW Idc=0.7mA
2025-11-07T22:20:24.851Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->12.8 due to current limit: Active-LoadBalancing
2025-11-07T22:20:24.863Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.5->21.3)
2025-11-07T22:20:36.851Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->12.6 due to current limit: Active-LoadBalancing
2025-11-07T22:20:36.863Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.3->21.0)
2025-11-07T22:20:44.292Z:USER:taskMaster.c:6684:Socket #1: L1N=231.9V L2N=232.3V L3N=231.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:20:44.304Z:USER:taskMaster.c:6720:Socket #1: I1=12.2A I2=12.3A I3=12.2A P=8.5kW Idc=0.7mA
2025-11-07T22:20:48.847Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->12.9 due to current limit: Active-LoadBalancing
2025-11-07T22:21:00.847Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.6 due to current limit: Active-LoadBalancing
2025-11-07T22:21:01.488Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-07T22:21:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:21:12.847Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->14.2 due to current limit: Active-LoadBalancing
2025-11-07T22:21:13.605Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.7% (14.2 A)
2025-11-07T22:21:14.289Z:USER:taskMaster.c:6684:Socket #1: L1N=231.8V L2N=232.1V L3N=231.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:21:14.304Z:USER:taskMaster.c:6720:Socket #1: I1=13.2A I2=13.2A I3=13.1A P=9.1kW Idc=0.7mA
2025-11-07T22:21:24.843Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.9 due to current limit: Active-LoadBalancing
2025-11-07T22:21:25.726Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.8% (14.9 A)
2025-11-07T22:21:36.843Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.5 due to current limit: Active-LoadBalancing
2025-11-07T22:21:37.843Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.8% (15.5 A)
2025-11-07T22:21:44.289Z:USER:taskMaster.c:6684:Socket #1: L1N=231.5V L2N=231.8V L3N=231.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:21:44.300Z:USER:taskMaster.c:6720:Socket #1: I1=15.1A I2=15.1A I3=15.0A P=10.5kW Idc=0.7mA
2025-11-07T22:21:48.843Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.8 due to current limit: Active-LoadBalancing
2025-11-07T22:22:00.839Z:INFO:taskMain.c:5996:Socket #1: Active current 15.8->15.6 due to current limit: Active-LoadBalancing
2025-11-07T22:22:00.855Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.2->26.0)
2025-11-07T22:22:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:22:12.839Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.5 due to current limit: Active-LoadBalancing
2025-11-07T22:22:12.851Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.0->25.7)
2025-11-07T22:22:14.285Z:USER:taskMaster.c:6684:Socket #1: L1N=231.6V L2N=232.0V L3N=231.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:22:14.296Z:USER:taskMaster.c:6720:Socket #1: I1=15.2A I2=15.3A I3=15.2A P=10.5kW Idc=0.7mA
2025-11-07T22:22:14.308Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-07T22:22:24.839Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->14.9 due to current limit: Active-LoadBalancing
2025-11-07T22:22:24.851Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->24.8)
2025-11-07T22:22:25.308Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.8% (14.9 A)
2025-11-07T22:22:36.835Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.3 due to current limit: Active-LoadBalancing
2025-11-07T22:22:36.851Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->23.8)
2025-11-07T22:22:37.429Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.8% (14.3 A)
2025-11-07T22:22:48.835Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-07T22:22:48.847Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-07T22:23:00.835Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-07T22:23:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:23:12.835Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-07T22:23:24.832Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T22:23:36.832Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-07T22:23:48.832Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-07T22:24:00.828Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.3)
2025-11-07T22:24:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:24:12.828Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-07T22:24:12.839Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-07T22:24:24.828Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-07T22:24:24.839Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-07T22:24:28.820Z:USER:taskMaster.c:6582:Temperature: 26.1 C
2025-11-07T22:24:34.968Z:INFO:active_lb.c:308:SMt:(15.0 16.0 16.0)A Free:(1.0 0.0 0.0)A ALB:(15.6 14.9 15.0)A
2025-11-07T22:24:36.824Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-07T22:24:36.835Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-07T22:24:48.824Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-07T22:25:00.824Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-07T22:25:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:25:12.820Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.4 due to current limit: Active-LoadBalancing
2025-11-07T22:25:24.820Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.3 due to current limit: Active-LoadBalancing
2025-11-07T22:25:24.832Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.6->25.4)
2025-11-07T22:25:36.820Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-07T22:25:36.832Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-07T22:25:48.816Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-07T22:25:48.832Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-07T22:26:00.816Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-07T22:26:00.828Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-07T22:26:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:26:12.816Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-07T22:26:24.812Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-07T22:26:24.828Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-07T22:26:36.812Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-07T22:26:48.812Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-07T22:26:48.824Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-07T22:27:00.808Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-07T22:27:00.824Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-07T22:27:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:27:12.808Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-07T22:27:24.808Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-07T22:27:36.804Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.5 due to current limit: Active-LoadBalancing
2025-11-07T22:27:48.804Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.3 due to current limit: Active-LoadBalancing
2025-11-07T22:27:48.816Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.8->25.5)
2025-11-07T22:28:00.804Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.2 due to current limit: Active-LoadBalancing
2025-11-07T22:28:00.816Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->25.3)
2025-11-07T22:28:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:28:12.800Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-07T22:28:12.816Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->24.9)
2025-11-07T22:28:24.800Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-07T22:28:24.812Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-07T22:28:36.800Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-07T22:28:36.812Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-07T22:28:48.796Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-07T22:28:48.812Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-07T22:29:00.796Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T22:29:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:29:12.796Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-07T22:29:24.792Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-07T22:29:24.808Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.7)
2025-11-07T22:29:36.792Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-07T22:29:36.804Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-07T22:29:48.792Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-07T22:29:48.804Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-07T22:30:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T22:30:00.789Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-07T22:30:00.804Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-07T22:30:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:30:12.789Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-07T22:30:12.800Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-07T22:30:24.789Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-07T22:30:36.789Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-07T22:30:48.785Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-07T22:31:00.785Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-07T22:31:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:31:12.785Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-07T22:31:12.796Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-07T22:31:24.781Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-07T22:31:24.792Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.7)
2025-11-07T22:31:36.781Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-07T22:31:36.792Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-07T22:31:48.781Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-07T22:31:48.792Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-07T22:32:00.777Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-07T22:32:00.792Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->24.0)
2025-11-07T22:32:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:32:12.777Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-07T22:32:24.777Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->15.1 due to current limit: Active-LoadBalancing
2025-11-07T22:32:25.175Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.1% (15.1 A)
2025-11-07T22:32:36.773Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.3 due to current limit: Active-LoadBalancing
2025-11-07T22:32:48.773Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-07T22:32:48.785Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-07T22:33:00.773Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-07T22:33:00.785Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-07T22:33:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:33:12.769Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-07T22:33:24.769Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-07T22:33:24.781Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->25.0)
2025-11-07T22:33:31.464Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-07T22:33:31.476Z:INFO:db_chargingprofi:26: socket 0
2025-11-07T22:33:31.484Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-07T22:33:31.492Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-07T22:33:31.500Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-07T22:33:31.507Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-07T22:33:31.519Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-07T22:33:31.527Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-07T22:33:31.535Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-07T22:33:31.542Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-07T22:33:31.550Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-07T22:33:31.558Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-07T22:33:31.566Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-07T22:33:31.578Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-07T22:33:31.585Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-07T22:33:31.593Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-07T22:33:31.601Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-07T22:33:31.613Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-07T22:33:31.621Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-07T22:33:31.628Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-07T22:33:31.636Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-07T22:33:31.644Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-07T22:33:31.652Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-07T22:33:36.769Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-07T22:33:48.765Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-07T22:33:48.781Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.2)
2025-11-07T22:34:00.765Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-07T22:34:00.777Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-07T22:34:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:34:12.765Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-07T22:34:12.777Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-07T22:34:24.761Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-07T22:34:24.777Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-07T22:34:34.906Z:INFO:active_lb.c:308:SMt:(15.0 16.0 15.0)A Free:(1.0 0.0 1.0)A ALB:(15.6 14.7 15.4)A
2025-11-07T22:34:36.761Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-07T22:34:36.773Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-07T22:34:48.761Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-07T22:34:48.773Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-07T22:35:00.757Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-07T22:35:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:35:12.757Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-07T22:35:24.757Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-07T22:35:36.753Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.4 due to current limit: Active-LoadBalancing
2025-11-07T22:35:48.753Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.6 due to current limit: Active-LoadBalancing
2025-11-07T22:36:00.753Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.5 due to current limit: Active-LoadBalancing
2025-11-07T22:36:00.765Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.0->25.7)
2025-11-07T22:36:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:36:12.750Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->14.9 due to current limit: Active-LoadBalancing
2025-11-07T22:36:12.765Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->24.9)
2025-11-07T22:36:13.410Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.9% (14.9 A)
2025-11-07T22:36:24.750Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-07T22:36:24.761Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-07T22:36:36.750Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-07T22:36:36.761Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-07T22:36:48.746Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-07T22:36:48.761Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-07T22:37:00.746Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T22:37:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:37:12.746Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-07T22:37:14.187Z:USER:taskMaster.c:6684:Socket #1: L1N=231.2V L2N=232.1V L3N=231.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:37:14.203Z:USER:taskMaster.c:6720:Socket #1: I1=14.3A I2=14.4A I3=14.3A P=9.9kW Idc=0.7mA
2025-11-07T22:37:24.746Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-07T22:37:36.742Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.1 due to current limit: Active-LoadBalancing
2025-11-07T22:37:36.753Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-07T22:37:48.742Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-07T22:37:48.753Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-07T22:38:00.742Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-07T22:38:00.753Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-07T22:38:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:38:12.738Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-07T22:38:24.738Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-07T22:38:36.738Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.5 due to current limit: Active-LoadBalancing
2025-11-07T22:38:48.734Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.3 due to current limit: Active-LoadBalancing
2025-11-07T22:38:48.746Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.8->25.5)
2025-11-07T22:39:00.734Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.2 due to current limit: Active-LoadBalancing
2025-11-07T22:39:00.746Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->25.3)
2025-11-07T22:39:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:39:12.734Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-07T22:39:12.746Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-07T22:39:24.730Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-07T22:39:24.746Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-07T22:39:29.226Z:USER:taskMaster.c:6582:Temperature: 28.0 C
2025-11-07T22:39:36.730Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-07T22:39:36.742Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-07T22:39:48.730Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-07T22:39:48.742Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-07T22:40:00.726Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T22:40:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:40:12.726Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-07T22:40:24.726Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.3 due to current limit: Active-LoadBalancing
2025-11-07T22:40:36.722Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.2 due to current limit: Active-LoadBalancing
2025-11-07T22:40:36.738Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->25.3)
2025-11-07T22:40:48.722Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-07T22:40:48.734Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-07T22:41:00.722Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-07T22:41:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:41:12.718Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.5 due to current limit: Active-LoadBalancing
2025-11-07T22:41:24.718Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.7 due to current limit: Active-LoadBalancing
2025-11-07T22:41:36.718Z:INFO:taskMain.c:5996:Socket #1: Active current 15.7->15.9 due to current limit: ChargingProfile
2025-11-07T22:41:36.761Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-07T22:41:48.714Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->26.3)
2025-11-07T22:41:48.761Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-07T22:42:00.714Z:INFO:taskMain.c:5996:Socket #1: Active current 15.8->15.6 due to current limit: Active-LoadBalancing
2025-11-07T22:42:00.726Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.3->26.0)
2025-11-07T22:42:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:42:12.714Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.5 due to current limit: Active-LoadBalancing
2025-11-07T22:42:12.726Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.0->25.7)
2025-11-07T22:42:24.710Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.3 due to current limit: Active-LoadBalancing
2025-11-07T22:42:24.726Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->25.4)
2025-11-07T22:42:36.710Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->14.8 due to current limit: Active-LoadBalancing
2025-11-07T22:42:36.722Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->24.5)
2025-11-07T22:42:37.179Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.5% (14.7 A)
2025-11-07T22:42:48.710Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-07T22:42:48.722Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-07T22:43:00.707Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-07T22:43:00.722Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-07T22:43:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:43:12.707Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-07T22:43:12.718Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.7)
2025-11-07T22:43:24.707Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-07T22:43:36.703Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T22:43:48.703Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-07T22:44:00.703Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-07T22:44:00.714Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-07T22:44:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:44:12.699Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-07T22:44:12.714Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-07T22:44:24.699Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-07T22:44:24.710Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-07T22:44:34.843Z:INFO:active_lb.c:308:SMt:(15.0 15.0 15.0)A Free:(1.0 1.0 1.0)A ALB:(14.4 15.4 15.4)A
2025-11-07T22:44:36.699Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-07T22:44:48.699Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-07T22:45:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T22:45:00.695Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-07T22:45:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:45:12.695Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.4 due to current limit: Active-LoadBalancing
2025-11-07T22:45:24.695Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.6 due to current limit: Active-LoadBalancing
2025-11-07T22:45:33.285Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-07T22:45:33.296Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-07T22:45:33.304Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-07T22:45:33.320Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-07T22:45:33.914Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-07T22:45:34.300Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-07T22:45:36.691Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->9.8 due to current limit: Active-LoadBalancing
2025-11-07T22:45:37.332Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.2% (9.7 A)
2025-11-07T22:45:48.691Z:INFO:taskMain.c:5996:Socket #1: Active current 9.8->5.9 due to current limit: Active-LoadBalancing
2025-11-07T22:45:48.703Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.85) < minimum current(6.00)
2025-11-07T22:45:48.734Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-07T22:45:48.746Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-07T22:45:48.753Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-07T22:45:49.449Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-07T22:45:49.730Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-11-07T22:45:49.730Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-07T22:46:00.691Z:INFO:taskMain.c:5996:Socket #1: Active current 5.9->9.5 due to current limit: Active-LoadBalancing
2025-11-07T22:46:00.734Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-07T22:46:00.742Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-07T22:46:00.753Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-07T22:46:00.839Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-07T22:46:01.738Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-07T22:46:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:46:12.687Z:INFO:taskMain.c:5996:Socket #1: Active current 9.5->11.7 due to current limit: Active-LoadBalancing
2025-11-07T22:46:12.847Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.5% (11.7 A)
2025-11-07T22:46:24.687Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->13.0 due to current limit: Active-LoadBalancing
2025-11-07T22:46:24.968Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.7% (13.0 A)
2025-11-07T22:46:30.781Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-07T22:46:30.789Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-07T22:46:31.027Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-07T22:46:31.035Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-07T22:46:31.777Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-07T22:46:34.781Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-07T22:46:34.804Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-07T22:46:34.812Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-07T22:46:35.281Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-07T22:46:35.292Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-07T22:46:35.816Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-07T22:46:36.304Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-07T22:46:36.687Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.8 due to current limit: Active-LoadBalancing
2025-11-07T22:46:37.316Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-07T22:46:48.683Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->14.3 due to current limit: Active-LoadBalancing
2025-11-07T22:46:49.433Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.8% (14.3 A)
2025-11-07T22:47:00.683Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-07T22:47:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:47:12.683Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-11-07T22:47:24.679Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T22:47:48.679Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.5 due to current limit: Active-LoadBalancing
2025-11-07T22:47:49.019Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-07T22:48:00.675Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-07T22:48:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:48:12.675Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-07T22:48:36.671Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-07T22:49:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:50:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:51:00.656Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-07T22:51:00.898Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-07T22:51:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:51:12.656Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-07T22:51:24.656Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T22:51:48.652Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T22:52:00.652Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.6 due to current limit: Active-LoadBalancing
2025-11-07T22:52:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:52:12.652Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T22:52:14.093Z:USER:taskMaster.c:6684:Socket #1: L1N=233.4V L2N=233.7V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T22:52:14.105Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T22:52:24.648Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.5 due to current limit: Active-LoadBalancing
2025-11-07T22:52:36.648Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T22:52:48.648Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T22:53:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:53:12.644Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T22:54:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:54:29.628Z:USER:taskMaster.c:6582:Temperature: 28.0 C
2025-11-07T22:54:34.781Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-07T22:54:36.636Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T22:54:37.015Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T22:54:48.632Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T22:55:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:55:12.632Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T22:56:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:56:12.625Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T22:56:12.957Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T22:56:24.625Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T22:56:48.621Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.5 due to current limit: Active-LoadBalancing
2025-11-07T22:56:49.312Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-07T22:57:00.621Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T22:57:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:57:12.617Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T22:57:36.617Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T22:58:00.613Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T22:58:01.015Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-07T22:58:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:58:12.613Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-11-07T22:58:24.613Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.4 due to current limit: Active-LoadBalancing
2025-11-07T22:58:36.609Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-07T22:58:48.609Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T22:59:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T22:59:12.605Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:00:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T23:00:00.105Z:INFO:taskMaster.c:6353:Socket #1: external current limit 15.9 A until 2025-11-08T23:00:00Z
2025-11-07T23:00:00.121Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-07T23:00:00.128Z:INFO:db_chargingprofi:26: socket 0
2025-11-07T23:00:00.136Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-07T23:00:00.148Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-07T23:00:00.152Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-07T23:00:00.164Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-07T23:00:00.175Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-07T23:00:00.183Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-07T23:00:00.191Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-07T23:00:00.199Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-07T23:00:00.207Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-07T23:00:00.214Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-07T23:00:00.222Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-07T23:00:00.230Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-07T23:00:00.238Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-07T23:00:00.250Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-07T23:00:00.257Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-07T23:00:00.265Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-07T23:00:00.277Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-07T23:00:00.285Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-07T23:00:00.292Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-07T23:00:00.300Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-07T23:00:00.308Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-07T23:00:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:00:36.597Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:00:37.546Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:00:48.597Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:01:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:01:12.593Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:02:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:02:12.585Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:02:13.488Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:02:24.585Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:02:48.582Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.5 due to current limit: Active-LoadBalancing
2025-11-07T23:02:48.832Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-07T23:03:00.582Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T23:03:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:03:12.582Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:03:36.578Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:04:00.574Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:04:01.546Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-07T23:04:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:04:12.574Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-11-07T23:04:24.574Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.4 due to current limit: Active-LoadBalancing
2025-11-07T23:04:34.714Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 14.4 15.0)A
2025-11-07T23:04:36.570Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-07T23:04:48.570Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:05:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:05:12.570Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:06:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:07:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:07:14.000Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.8V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T23:07:14.011Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T23:08:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:09:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:09:29.886Z:USER:taskMaster.c:6582:Temperature: 26.6 C
2025-11-07T23:10:00.539Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:10:01.066Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:10:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:10:12.535Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:10:24.535Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.5 due to current limit: Active-LoadBalancing
2025-11-07T23:10:36.535Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T23:10:48.531Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:11:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:11:12.531Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:12:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:12:12.523Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:12:13.363Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:12:24.523Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:12:48.519Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:13:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:14:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:14:34.652Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-07T23:15:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T23:15:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:16:00.500Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:16:00.589Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:16:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:16:12.500Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:16:24.496Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.5 due to current limit: Active-LoadBalancing
2025-11-07T23:16:36.496Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T23:16:48.496Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:17:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:17:12.492Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:18:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:18:12.484Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:18:12.886Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:18:24.484Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:18:48.480Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:19:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:19:48.476Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:19:48.824Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:20:00.476Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:20:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:20:04.820Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000022, address 0x00022000 (1)
2025-11-07T23:20:04.828Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-07T23:20:24.472Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:21:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:22:00.460Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:22:01.121Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:22:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:22:12.460Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:22:13.906Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.8V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T23:22:13.917Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T23:22:36.457Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:23:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:23:36.453Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:23:37.062Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:23:48.449Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:24:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:24:12.449Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.5 due to current limit: Active-LoadBalancing
2025-11-07T23:24:13.417Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-07T23:24:24.445Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T23:24:30.289Z:USER:taskMaster.c:6582:Temperature: 25.5 C
2025-11-07T23:24:34.589Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 14.7 15.0)A
2025-11-07T23:24:36.445Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:25:00.441Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:25:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:26:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:27:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:28:00.425Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:28:00.644Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:28:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:28:12.421Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:28:36.421Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:29:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:29:36.414Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:29:36.585Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:29:48.414Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:30:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T23:30:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:30:12.410Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.5 due to current limit: Active-LoadBalancing
2025-11-07T23:30:12.941Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-07T23:30:24.460Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T23:30:36.457Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:31:00.457Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:31:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:31:48.449Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:31:48.878Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:32:00.449Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:32:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:32:24.445Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:33:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:34:00.437Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:34:01.175Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:34:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:34:12.433Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:34:26.125Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-07T23:34:26.136Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-07T23:34:34.527Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 14.9 15.0)A
2025-11-07T23:34:36.433Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:35:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:35:36.425Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:35:37.117Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:35:48.425Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:36:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:36:12.421Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.5 due to current limit: Active-LoadBalancing
2025-11-07T23:36:12.460Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-07T23:36:24.421Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T23:36:36.417Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:37:00.417Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:37:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:37:13.808Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.9V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T23:37:13.820Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T23:38:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:38:24.410Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:38:24.757Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:38:36.406Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:39:00.406Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:39:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:39:30.644Z:USER:taskMaster.c:6582:Temperature: 25.0 C
2025-11-07T23:39:36.402Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:39:36.460Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:39:48.398Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-11-07T23:40:00.398Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.4 due to current limit: Active-LoadBalancing
2025-11-07T23:40:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:40:12.398Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-07T23:40:24.394Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:40:48.394Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:41:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:42:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:42:12.382Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:42:12.996Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:42:24.382Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:42:48.378Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:43:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:43:48.375Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:43:48.933Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:44:00.371Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:44:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:44:24.371Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:44:34.464Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 14.9 15.0)A
2025-11-07T23:45:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-07T23:45:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:45:36.363Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:45:36.992Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:45:48.363Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:46:00.359Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.5 due to current limit: Active-LoadBalancing
2025-11-07T23:46:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:46:12.359Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T23:46:24.359Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:46:48.355Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:47:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:48:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:48:12.347Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:48:12.515Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:48:24.343Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:48:48.343Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:49:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:49:48.335Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:49:48.457Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:50:00.335Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:50:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:50:24.332Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:51:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:51:36.324Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:51:36.515Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:51:48.324Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:52:00.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.5 due to current limit: Active-LoadBalancing
2025-11-07T23:52:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:52:12.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-07T23:52:13.714Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=234.0V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-07T23:52:13.726Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-07T23:52:24.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:52:48.316Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:53:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:54:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:54:31.000Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-07T23:54:34.398Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-07T23:55:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:56:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:57:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:57:36.335Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:57:37.046Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-07T23:57:48.335Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-07T23:58:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:58:12.332Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-07T23:59:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-07T23:59:48.324Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-07T23:59:48.335Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-08T00:00:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T00:00:00.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:00:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:00:07.617Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-08T00:00:07.628Z:INFO:db_chargingprofi:26: socket 0
2025-11-08T00:00:07.636Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-08T00:00:07.644Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-08T00:00:07.652Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-08T00:00:07.660Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-08T00:00:07.671Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-08T00:00:07.679Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-08T00:00:07.687Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-08T00:00:07.699Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-08T00:00:07.707Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-08T00:00:07.714Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-08T00:00:07.722Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-08T00:00:07.730Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-08T00:00:07.738Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-08T00:00:07.746Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-08T00:00:07.757Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-08T00:00:07.765Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-08T00:00:07.773Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-08T00:00:07.781Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-08T00:00:07.789Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-08T00:00:07.796Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-08T00:00:07.808Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-08T00:00:24.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T00:01:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:01:24.312Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-08T00:01:25.281Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-08T00:01:36.312Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:02:00.308Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T00:02:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:03:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:03:36.296Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-08T00:03:36.570Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-08T00:03:48.296Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:04:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:04:12.292Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T00:04:34.335Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 14.9 15.0)A
2025-11-08T00:05:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:05:48.285Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-08T00:05:48.863Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-08T00:06:00.285Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:06:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:06:24.281Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T00:07:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:07:13.621Z:USER:taskMaster.c:6684:Socket #1: L1N=233.4V L2N=234.1V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T00:07:13.632Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-08T00:08:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:08:24.269Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-08T00:08:24.386Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-08T00:08:36.265Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:08:48.265Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->12.6 due to current limit: Active-LoadBalancing
2025-11-08T00:08:48.625Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-11-08T00:09:00.265Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->11.2 due to current limit: Active-LoadBalancing
2025-11-08T00:09:00.746Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.6% (11.2 A)
2025-11-08T00:09:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:09:12.261Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->10.3 due to current limit: Active-LoadBalancing
2025-11-08T00:09:12.863Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.1% (10.3 A)
2025-11-08T00:09:24.261Z:INFO:taskMain.c:5996:Socket #1: Active current 10.3->9.8 due to current limit: Active-LoadBalancing
2025-11-08T00:09:24.980Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.2% (9.7 A)
2025-11-08T00:09:31.406Z:USER:taskMaster.c:6582:Temperature: 24.0 C
2025-11-08T00:09:36.261Z:INFO:taskMain.c:5996:Socket #1: Active current 9.8->9.5 due to current limit: Active-LoadBalancing
2025-11-08T00:09:48.257Z:INFO:taskMain.c:5996:Socket #1: Active current 9.5->9.3 due to current limit: Active-LoadBalancing
2025-11-08T00:10:00.257Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->9.2 due to current limit: Active-LoadBalancing
2025-11-08T00:10:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:10:24.253Z:INFO:taskMain.c:5996:Socket #1: Active current 9.1->9.1 due to current limit: Active-LoadBalancing
2025-11-08T00:11:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:12:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:12:24.242Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.6 due to current limit: Active-LoadBalancing
2025-11-08T00:12:24.742Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.3% (8.6 A)
2025-11-08T00:12:36.242Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.4 due to current limit: Active-LoadBalancing
2025-11-08T00:12:48.242Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.2 due to current limit: Active-LoadBalancing
2025-11-08T00:13:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:13:12.238Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->8.1 due to current limit: Active-LoadBalancing
2025-11-08T00:14:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:14:12.230Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->8.4 due to current limit: Active-LoadBalancing
2025-11-08T00:14:12.800Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.0% (8.4 A)
2025-11-08T00:14:24.230Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.6 due to current limit: Active-LoadBalancing
2025-11-08T00:14:34.273Z:INFO:active_lb.c:308:SMt:(7.0 1.0 1.0)A Free:(9.0 15.0 15.0)A ALB:(8.6 15.0 15.0)A
2025-11-08T00:14:36.230Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.8 due to current limit: Active-LoadBalancing
2025-11-08T00:15:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T00:15:00.226Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.9 due to current limit: Active-LoadBalancing
2025-11-08T00:15:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:16:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:17:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:18:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:19:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:19:48.195Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.6 due to current limit: Active-LoadBalancing
2025-11-08T00:19:49.097Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.3% (8.6 A)
2025-11-08T00:20:00.195Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.4 due to current limit: Active-LoadBalancing
2025-11-08T00:20:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:20:12.191Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.2 due to current limit: Active-LoadBalancing
2025-11-08T00:20:36.191Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->8.1 due to current limit: Active-LoadBalancing
2025-11-08T00:21:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:22:00.183Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->8.4 due to current limit: Active-LoadBalancing
2025-11-08T00:22:00.382Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.0% (8.4 A)
2025-11-08T00:22:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:22:04.625Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000023, address 0x00023000 (1)
2025-11-08T00:22:04.636Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-08T00:22:12.179Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.6 due to current limit: Active-LoadBalancing
2025-11-08T00:22:13.523Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=233.9V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T00:22:13.535Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-08T00:22:24.179Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.8 due to current limit: Active-LoadBalancing
2025-11-08T00:22:48.175Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.9 due to current limit: Active-LoadBalancing
2025-11-08T00:23:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:23:12.175Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->11.4 due to current limit: Active-LoadBalancing
2025-11-08T00:23:13.093Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.9% (11.3 A)
2025-11-08T00:23:24.171Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->12.8 due to current limit: Active-LoadBalancing
2025-11-08T00:23:24.203Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.3% (12.8 A)
2025-11-08T00:23:36.171Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->13.7 due to current limit: Active-LoadBalancing
2025-11-08T00:23:36.320Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.8% (13.7 A)
2025-11-08T00:23:48.171Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->14.2 due to current limit: Active-LoadBalancing
2025-11-08T00:23:48.441Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.6% (14.2 A)
2025-11-08T00:24:00.167Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-08T00:24:00.558Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-08T00:24:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:24:12.167Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T00:24:24.167Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:24:31.761Z:USER:taskMaster.c:6582:Temperature: 23.6 C
2025-11-08T00:24:34.210Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.8 14.9 15.0)A
2025-11-08T00:24:48.164Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T00:25:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:25:12.160Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-08T00:25:12.261Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-08T00:25:24.160Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:25:48.156Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->12.6 due to current limit: Active-LoadBalancing
2025-11-08T00:25:48.617Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.9% (12.5 A)
2025-11-08T00:26:00.156Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->11.2 due to current limit: Active-LoadBalancing
2025-11-08T00:26:00.738Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.5% (11.1 A)
2025-11-08T00:26:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:26:12.156Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->10.3 due to current limit: Active-LoadBalancing
2025-11-08T00:26:12.855Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.1% (10.3 A)
2025-11-08T00:26:24.152Z:INFO:taskMain.c:5996:Socket #1: Active current 10.3->9.8 due to current limit: Active-LoadBalancing
2025-11-08T00:26:24.972Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.2% (9.7 A)
2025-11-08T00:26:36.152Z:INFO:taskMain.c:5996:Socket #1: Active current 9.8->9.5 due to current limit: Active-LoadBalancing
2025-11-08T00:26:48.152Z:INFO:taskMain.c:5996:Socket #1: Active current 9.5->9.3 due to current limit: Active-LoadBalancing
2025-11-08T00:27:00.148Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->9.2 due to current limit: Active-LoadBalancing
2025-11-08T00:27:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:27:24.148Z:INFO:taskMain.c:5996:Socket #1: Active current 9.1->9.1 due to current limit: Active-LoadBalancing
2025-11-08T00:28:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:29:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:30:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T00:30:00.132Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->8.6 due to current limit: Active-LoadBalancing
2025-11-08T00:30:01.089Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.3% (8.6 A)
2025-11-08T00:30:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:30:12.128Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.4 due to current limit: Active-LoadBalancing
2025-11-08T00:30:24.128Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.2 due to current limit: Active-LoadBalancing
2025-11-08T00:30:48.125Z:INFO:taskMain.c:5996:Socket #1: Active current 8.1->8.1 due to current limit: Active-LoadBalancing
2025-11-08T00:31:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:31:24.121Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->8.4 due to current limit: Active-LoadBalancing
2025-11-08T00:31:24.910Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.0% (8.4 A)
2025-11-08T00:31:36.121Z:INFO:taskMain.c:5996:Socket #1: Active current 8.4->8.7 due to current limit: Active-LoadBalancing
2025-11-08T00:31:48.121Z:INFO:taskMain.c:5996:Socket #1: Active current 8.7->8.8 due to current limit: Active-LoadBalancing
2025-11-08T00:32:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:32:12.117Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->8.9 due to current limit: Active-LoadBalancing
2025-11-08T00:33:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:34:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:34:34.144Z:INFO:active_lb.c:308:SMt:(7.0 1.0 1.0)A Free:(9.0 15.0 15.0)A ALB:(9.0 15.0 15.0)A
2025-11-08T00:35:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:36:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:36:36.089Z:INFO:taskMain.c:5996:Socket #1: Active current 9.0->11.4 due to current limit: Active-LoadBalancing
2025-11-08T00:36:36.960Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.9% (11.3 A)
2025-11-08T00:36:48.089Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->12.8 due to current limit: Active-LoadBalancing
2025-11-08T00:36:49.078Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.3% (12.8 A)
2025-11-08T00:37:00.085Z:INFO:taskMain.c:5996:Socket #1: Active current 12.8->13.7 due to current limit: Active-LoadBalancing
2025-11-08T00:37:00.187Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.8% (13.7 A)
2025-11-08T00:37:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:37:12.085Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->14.2 due to current limit: Active-LoadBalancing
2025-11-08T00:37:12.304Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.7% (14.2 A)
2025-11-08T00:37:13.429Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.6V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T00:37:13.441Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-08T00:37:24.085Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-08T00:37:36.082Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T00:37:48.082Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T00:38:00.082Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:38:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:38:24.078Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T00:39:00.074Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-08T00:39:00.363Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-08T00:39:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:39:12.074Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-11-08T00:39:24.070Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.4 due to current limit: Active-LoadBalancing
2025-11-08T00:39:32.164Z:USER:taskMaster.c:6582:Temperature: 23.4 C
2025-11-08T00:39:36.070Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-08T00:39:48.070Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:40:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:40:12.066Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T00:40:36.062Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-08T00:40:36.304Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.2% (14.5 A)
2025-11-08T00:40:48.062Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-11-08T00:41:00.062Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:41:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:41:12.058Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.5 due to current limit: Active-LoadBalancing
2025-11-08T00:41:12.660Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-08T00:41:24.058Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T00:41:36.058Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:42:00.054Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T00:42:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:42:48.050Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-08T00:42:48.601Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-08T00:43:00.046Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:43:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:43:24.046Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T00:44:00.042Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.2 due to current limit: Active-LoadBalancing
2025-11-08T00:44:00.300Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.6% (14.2 A)
2025-11-08T00:44:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:44:12.039Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->13.7 due to current limit: Active-LoadBalancing
2025-11-08T00:44:12.421Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.8% (13.7 A)
2025-11-08T00:44:24.039Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->13.4 due to current limit: Active-LoadBalancing
2025-11-08T00:44:34.082Z:INFO:active_lb.c:308:SMt:(3.0 1.0 1.0)A Free:(13.0 15.0 15.0)A ALB:(13.4 15.0 15.0)A
2025-11-08T00:44:36.039Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.3 due to current limit: Active-LoadBalancing
2025-11-08T00:44:48.035Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.2 due to current limit: Active-LoadBalancing
2025-11-08T00:45:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T00:45:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:45:24.035Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.0 due to current limit: Active-LoadBalancing
2025-11-08T00:45:36.031Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.8 due to current limit: Active-LoadBalancing
2025-11-08T00:45:36.242Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-08T00:45:48.031Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->14.3 due to current limit: Active-LoadBalancing
2025-11-08T00:45:48.359Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.8% (14.3 A)
2025-11-08T00:46:00.031Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-08T00:46:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:46:12.027Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-11-08T00:46:24.027Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:47:00.023Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.0 due to current limit: Active-LoadBalancing
2025-11-08T00:47:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:47:12.023Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-08T00:47:12.183Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-08T00:47:24.019Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:47:48.019Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T00:48:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:48:48.011Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-08T00:48:48.121Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-08T00:49:00.011Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:49:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:49:24.007Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.5 due to current limit: Active-LoadBalancing
2025-11-08T00:49:24.476Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-08T00:49:36.007Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T00:49:48.003Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:50:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:50:12.003Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T00:50:59.996Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-08T00:51:00.417Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-08T00:51:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:51:11.996Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:51:35.992Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T00:52:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:52:13.332Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=234.9V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T00:52:13.347Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-08T00:53:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:53:11.984Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-08T00:53:12.714Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-08T00:53:23.980Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:53:47.980Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T00:54:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:54:32.519Z:USER:taskMaster.c:6582:Temperature: 23.1 C
2025-11-08T00:54:34.019Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-08T00:54:47.972Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-08T00:54:48.652Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-08T00:54:59.972Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:55:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:55:23.968Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.5 due to current limit: Active-LoadBalancing
2025-11-08T00:55:24.000Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-08T00:55:35.968Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T00:55:47.968Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:56:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:56:11.964Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T00:56:59.960Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-08T00:57:00.949Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-08T00:57:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:57:11.957Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T00:57:35.957Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T00:58:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T00:59:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:00:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T01:00:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:00:15.187Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-08T01:00:15.195Z:INFO:db_chargingprofi:26: socket 0
2025-11-08T01:00:15.203Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-08T01:00:15.210Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-08T01:00:15.218Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-08T01:00:15.230Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-08T01:00:15.238Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-08T01:00:15.246Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-08T01:00:15.257Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-08T01:00:15.265Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-08T01:00:15.273Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-08T01:00:15.281Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-08T01:00:15.289Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-08T01:00:15.296Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-08T01:00:15.304Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-08T01:00:15.316Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-08T01:00:15.324Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-08T01:00:15.332Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-08T01:00:15.339Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-08T01:00:15.347Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-08T01:00:15.355Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-08T01:00:15.363Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-08T01:00:15.371Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-08T01:01:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:01:23.929Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:01:24.531Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-08T01:01:35.929Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T01:01:47.929Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-08T01:02:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:02:11.925Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-08T01:02:59.921Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-08T01:03:00.472Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-08T01:03:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:03:11.921Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:03:23.917Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:03:35.917Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.5 due to current limit: Active-LoadBalancing
2025-11-08T01:03:47.917Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T01:03:59.914Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:04:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:04:23.914Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T01:04:33.957Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 14.9 15.0)A
2025-11-08T01:05:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:05:11.906Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:05:12.757Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-08T01:05:23.906Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:05:47.902Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T01:06:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:07:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:07:13.238Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=236.1V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:07:13.250Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=1.0mA
2025-11-08T01:07:35.890Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->11.8 due to current limit: Active-LoadBalancing
2025-11-08T01:07:36.160Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.6% (11.8 A)
2025-11-08T01:07:47.890Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->9.9 due to current limit: Active-LoadBalancing
2025-11-08T01:07:48.281Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.4% (9.8 A)
2025-11-08T01:07:59.890Z:INFO:taskMain.c:5996:Socket #1: Active current 9.9->8.7 due to current limit: Active-LoadBalancing
2025-11-08T01:08:00.398Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.5% (8.7 A)
2025-11-08T01:08:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:08:11.886Z:INFO:taskMain.c:5996:Socket #1: Active current 8.7->8.0 due to current limit: Active-LoadBalancing
2025-11-08T01:08:12.519Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.3% (8.0 A)
2025-11-08T01:08:23.886Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->7.6 due to current limit: Active-LoadBalancing
2025-11-08T01:08:24.636Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.7% (7.6 A)
2025-11-08T01:08:35.886Z:INFO:taskMain.c:5996:Socket #1: Active current 7.6->7.4 due to current limit: Active-LoadBalancing
2025-11-08T01:08:47.882Z:INFO:taskMain.c:5996:Socket #1: Active current 7.4->7.2 due to current limit: Active-LoadBalancing
2025-11-08T01:09:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:09:11.882Z:INFO:taskMain.c:5996:Socket #1: Active current 7.1->7.1 due to current limit: Active-LoadBalancing
2025-11-08T01:09:32.921Z:USER:taskMaster.c:6582:Temperature: 23.1 C
2025-11-08T01:09:47.878Z:INFO:taskMain.c:5996:Socket #1: Active current 7.0->10.2 due to current limit: Active-LoadBalancing
2025-11-08T01:09:48.457Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.0% (10.2 A)
2025-11-08T01:09:59.875Z:INFO:taskMain.c:5996:Socket #1: Active current 10.2->12.1 due to current limit: Active-LoadBalancing
2025-11-08T01:10:00.578Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.2% (12.1 A)
2025-11-08T01:10:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:10:11.875Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->13.3 due to current limit: Active-LoadBalancing
2025-11-08T01:10:12.695Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.1% (13.3 A)
2025-11-08T01:10:23.875Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->14.0 due to current limit: Active-LoadBalancing
2025-11-08T01:10:24.812Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.2% (13.9 A)
2025-11-08T01:10:35.875Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-08T01:10:35.921Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.9% (14.3 A)
2025-11-08T01:10:47.871Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:10:59.871Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:11:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:11:23.867Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T01:12:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:12:59.859Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->13.4 due to current limit: Active-LoadBalancing
2025-11-08T01:13:00.335Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-08T01:13:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:13:11.855Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->14.0 due to current limit: Active-LoadBalancing
2025-11-08T01:13:12.457Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.4% (14.0 A)
2025-11-08T01:13:23.855Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->14.4 due to current limit: Active-LoadBalancing
2025-11-08T01:13:24.574Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.0% (14.4 A)
2025-11-08T01:13:35.855Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-08T01:13:47.851Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:14:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:14:11.851Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T01:14:33.890Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-08T01:15:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T01:15:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:15:59.839Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:16:00.097Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.3% (14.6 A)
2025-11-08T01:16:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:16:11.835Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T01:16:23.835Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-08T01:16:47.832Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.1 due to current limit: Active-LoadBalancing
2025-11-08T01:17:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:17:11.832Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->11.2 due to current limit: Active-LoadBalancing
2025-11-08T01:17:12.812Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.7% (11.2 A)
2025-11-08T01:17:23.828Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->9.5 due to current limit: Active-LoadBalancing
2025-11-08T01:17:23.917Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.8% (9.5 A)
2025-11-08T01:17:35.828Z:INFO:taskMain.c:5996:Socket #1: Active current 9.5->8.5 due to current limit: Active-LoadBalancing
2025-11-08T01:17:36.039Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.2% (8.5 A)
2025-11-08T01:17:47.828Z:INFO:taskMain.c:5996:Socket #1: Active current 8.5->7.9 due to current limit: Active-LoadBalancing
2025-11-08T01:17:48.156Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.1% (7.9 A)
2025-11-08T01:17:59.824Z:INFO:taskMain.c:5996:Socket #1: Active current 7.9->7.5 due to current limit: Active-LoadBalancing
2025-11-08T01:18:00.277Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.5% (7.5 A)
2025-11-08T01:18:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:18:11.824Z:INFO:taskMain.c:5996:Socket #1: Active current 7.5->7.3 due to current limit: Active-LoadBalancing
2025-11-08T01:18:23.824Z:INFO:taskMain.c:5996:Socket #1: Active current 7.3->7.2 due to current limit: Active-LoadBalancing
2025-11-08T01:18:47.820Z:INFO:taskMain.c:5996:Socket #1: Active current 7.1->7.1 due to current limit: Active-LoadBalancing
2025-11-08T01:19:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:20:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:20:59.808Z:INFO:taskMain.c:5996:Socket #1: Active current 7.0->6.6 due to current limit: Active-LoadBalancing
2025-11-08T01:21:00.035Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.0% (6.6 A)
2025-11-08T01:21:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:21:11.804Z:INFO:taskMain.c:5996:Socket #1: Active current 6.6->6.4 due to current limit: Active-LoadBalancing
2025-11-08T01:21:23.804Z:INFO:taskMain.c:5996:Socket #1: Active current 6.4->6.2 due to current limit: Active-LoadBalancing
2025-11-08T01:21:47.800Z:INFO:taskMain.c:5996:Socket #1: Active current 6.1->9.3 due to current limit: Active-LoadBalancing
2025-11-08T01:21:48.511Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.4% (9.2 A)
2025-11-08T01:21:59.800Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->11.6 due to current limit: Active-LoadBalancing
2025-11-08T01:22:00.628Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.2% (11.5 A)
2025-11-08T01:22:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:22:11.800Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->12.9 due to current limit: Active-LoadBalancing
2025-11-08T01:22:12.750Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.5% (12.9 A)
2025-11-08T01:22:13.144Z:USER:taskMaster.c:6684:Socket #1: L1N=235.3V L2N=235.9V L3N=236.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:22:13.156Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-08T01:22:21.644Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-08T01:22:21.652Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-08T01:22:21.664Z:USER:taskMaster.c:6684:Socket #1: L1N=235.2V L2N=235.8V L3N=236.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:22:21.675Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=1.3mA
2025-11-08T01:22:21.683Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-08T01:22:21.695Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-08T01:22:21.703Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-08T01:22:21.839Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-08T01:22:22.636Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-08T01:22:23.796Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->14.0 due to current limit: Active-LoadBalancing
2025-11-08T01:22:24.656Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.2% (13.9 A)
2025-11-08T01:22:35.796Z:INFO:taskMain.c:5996:Socket #1: Active current 14.0->15.9 due to current limit: ChargingProfile
2025-11-08T01:22:35.839Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-08T01:22:36.777Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-08T01:22:51.687Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.1V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:22:51.703Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.5A I3=15.4A P=10.9kW Idc=1.0mA
2025-11-08T01:23:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:23:04.488Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000024, address 0x00024000 (1)
2025-11-08T01:23:04.500Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-08T01:23:21.621Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-08T01:23:21.687Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=234.3V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:23:21.699Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.5A I3=15.4A P=10.9kW Idc=0.7mA
2025-11-08T01:23:35.789Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.8 due to current limit: Active-LoadBalancing
2025-11-08T01:23:35.804Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->26.2)
2025-11-08T01:23:35.835Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-08T01:23:47.789Z:INFO:taskMain.c:5996:Socket #1: Active current 15.8->15.2 due to current limit: Active-LoadBalancing
2025-11-08T01:23:47.800Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.2->25.3)
2025-11-08T01:23:48.480Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.3% (15.2 A)
2025-11-08T01:23:51.683Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=234.5V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:23:51.695Z:USER:taskMaster.c:6720:Socket #1: I1=14.7A I2=14.8A I3=14.6A P=10.3kW Idc=0.7mA
2025-11-08T01:23:59.789Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:23:59.800Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->24.4)
2025-11-08T01:24:00.597Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.4% (14.6 A)
2025-11-08T01:24:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:24:11.785Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-08T01:24:11.800Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T01:24:21.679Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.6V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:24:21.691Z:USER:taskMaster.c:6720:Socket #1: I1=14.0A I2=14.1A I3=14.0A P=9.8kW Idc=0.7mA
2025-11-08T01:24:23.785Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-08T01:24:23.796Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-08T01:24:33.328Z:USER:taskMaster.c:6582:Temperature: 23.0 C
2025-11-08T01:24:33.828Z:INFO:active_lb.c:308:SMt:(14.0 16.0 15.0)A Free:(2.0 0.0 1.0)A ALB:(15.2 14.3 15.2)A
2025-11-08T01:24:35.785Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-08T01:24:35.796Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-08T01:24:47.781Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-08T01:24:51.675Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.6V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:24:51.687Z:USER:taskMaster.c:6720:Socket #1: I1=14.0A I2=14.0A I3=13.9A P=9.8kW Idc=0.7mA
2025-11-08T01:24:59.781Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-08T01:25:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:25:11.781Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-08T01:25:21.671Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.5V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:25:21.683Z:USER:taskMaster.c:6720:Socket #1: I1=14.5A I2=14.5A I3=14.4A P=10.2kW Idc=0.7mA
2025-11-08T01:25:23.777Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:25:23.792Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.6)
2025-11-08T01:25:35.777Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:25:35.789Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T01:25:47.777Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-08T01:25:47.789Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T01:25:51.671Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.0V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:25:51.683Z:USER:taskMaster.c:6720:Socket #1: I1=14.0A I2=14.1A I3=13.9A P=9.8kW Idc=0.7mA
2025-11-08T01:25:59.773Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-08T01:25:59.789Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-08T01:26:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:26:11.773Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-08T01:26:21.667Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.1V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:26:21.679Z:USER:taskMaster.c:6720:Socket #1: I1=14.2A I2=14.2A I3=14.1A P=9.9kW Idc=0.7mA
2025-11-08T01:26:23.773Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:26:35.769Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T01:26:47.769Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T01:26:47.781Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T01:26:51.664Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.0V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:26:51.675Z:USER:taskMaster.c:6720:Socket #1: I1=14.4A I2=14.5A I3=14.5A P=10.1kW Idc=0.7mA
2025-11-08T01:26:59.769Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:26:59.781Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.6)
2025-11-08T01:27:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:27:11.765Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:27:11.781Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T01:27:21.660Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=234.4V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:27:21.671Z:USER:taskMaster.c:6720:Socket #1: I1=14.2A I2=14.2A I3=14.1A P=10.0kW Idc=0.7mA
2025-11-08T01:27:21.683Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-08T01:27:23.765Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-08T01:27:23.777Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T01:27:35.765Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-08T01:27:35.777Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-08T01:27:47.761Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-08T01:27:59.761Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:28:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:28:11.761Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T01:28:23.761Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.3 due to current limit: Active-LoadBalancing
2025-11-08T01:28:35.757Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.6 due to current limit: Active-LoadBalancing
2025-11-08T01:28:47.757Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.4 due to current limit: Active-LoadBalancing
2025-11-08T01:28:47.769Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.9->25.7)
2025-11-08T01:28:59.757Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.3 due to current limit: Active-LoadBalancing
2025-11-08T01:28:59.769Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->25.4)
2025-11-08T01:29:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:29:11.753Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-08T01:29:11.765Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.2)
2025-11-08T01:29:23.753Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-08T01:29:23.765Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-08T01:29:35.753Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:29:35.765Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-08T01:29:47.750Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-08T01:29:47.761Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-08T01:29:59.750Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:29:59.761Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T01:30:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T01:30:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:30:11.750Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:30:23.746Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T01:30:35.746Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.4 due to current limit: Active-LoadBalancing
2025-11-08T01:30:47.746Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.2 due to current limit: Active-LoadBalancing
2025-11-08T01:30:47.757Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.6->25.3)
2025-11-08T01:30:59.742Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-08T01:30:59.757Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-08T01:31:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:31:11.742Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:31:11.753Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.7)
2025-11-08T01:31:23.742Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-08T01:31:23.753Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-08T01:31:35.738Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-08T01:31:35.753Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T01:31:47.738Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-08T01:31:47.750Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-08T01:31:59.738Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-08T01:31:59.750Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-08T01:32:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:32:11.734Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:32:12.425Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.6% (14.8 A)
2025-11-08T01:32:23.734Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-08T01:32:35.734Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-08T01:32:47.730Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.6 due to current limit: Active-LoadBalancing
2025-11-08T01:32:59.730Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.5 due to current limit: Active-LoadBalancing
2025-11-08T01:32:59.742Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.0->25.7)
2025-11-08T01:33:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:33:11.730Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.3 due to current limit: Active-LoadBalancing
2025-11-08T01:33:11.742Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->25.5)
2025-11-08T01:33:23.726Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.2 due to current limit: Active-LoadBalancing
2025-11-08T01:33:23.742Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->25.3)
2025-11-08T01:33:35.726Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-08T01:33:35.738Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-08T01:33:47.726Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T01:33:47.738Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T01:33:59.722Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T01:33:59.738Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T01:34:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:34:11.722Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:34:11.734Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T01:34:19.785Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-08T01:34:20.054Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-08T01:34:23.722Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-08T01:34:23.734Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.1)
2025-11-08T01:34:25.363Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-08T01:34:25.375Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-08T01:34:33.765Z:INFO:active_lb.c:308:SMt:(15.0 15.0 15.0)A Free:(1.0 1.0 1.0)A ALB:(15.3 14.5 15.2)A
2025-11-08T01:34:35.718Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T01:34:47.718Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-08T01:34:59.718Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-08T01:35:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:35:11.714Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-08T01:35:11.730Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-08T01:35:23.714Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T01:35:23.726Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T01:35:35.714Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:35:35.726Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T01:35:47.714Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:35:47.726Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T01:35:59.710Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-08T01:35:59.722Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.1)
2025-11-08T01:36:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:36:11.710Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T01:36:23.710Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-08T01:36:35.707Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-08T01:36:47.707Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-08T01:36:47.718Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-08T01:36:59.707Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T01:36:59.718Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T01:37:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:37:11.703Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:37:11.714Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T01:37:23.703Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:37:23.714Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T01:37:35.703Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-08T01:37:35.714Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.1)
2025-11-08T01:37:47.699Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T01:37:59.699Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-08T01:38:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:38:11.699Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:38:11.710Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-08T01:38:23.695Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-08T01:38:23.710Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-08T01:38:35.695Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-08T01:38:35.707Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T01:38:47.695Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T01:38:59.691Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-08T01:39:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:39:11.691Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T01:39:11.703Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T01:39:23.691Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T01:39:23.703Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T01:39:33.683Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-08T01:39:35.687Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:39:35.703Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T01:39:47.687Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-08T01:39:59.687Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-08T01:40:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:40:11.683Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-08T01:40:11.699Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-08T01:40:23.683Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:40:23.695Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-08T01:40:35.683Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-08T01:40:35.695Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-08T01:40:37.777Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-08T01:40:37.785Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-08T01:40:37.796Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-08T01:40:37.804Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-08T01:40:38.382Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-08T01:40:38.792Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-08T01:40:47.679Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->9.2 due to current limit: Active-LoadBalancing
2025-11-08T01:40:47.882Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.3% (9.2 A)
2025-11-08T01:40:59.679Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->11.5 due to current limit: Active-LoadBalancing
2025-11-08T01:41:00.000Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.1% (11.5 A)
2025-11-08T01:41:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:41:11.679Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->12.9 due to current limit: Active-LoadBalancing
2025-11-08T01:41:12.117Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.5% (12.9 A)
2025-11-08T01:41:23.675Z:INFO:taskMain.c:5996:Socket #1: Active current 12.9->13.7 due to current limit: Active-LoadBalancing
2025-11-08T01:41:24.238Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.9% (13.7 A)
2025-11-08T01:41:35.675Z:INFO:taskMain.c:5996:Socket #1: Active current 13.7->14.2 due to current limit: Active-LoadBalancing
2025-11-08T01:41:36.355Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.7% (14.2 A)
2025-11-08T01:41:47.675Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-08T01:41:59.671Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T01:42:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:42:11.671Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:42:21.566Z:USER:taskMaster.c:6684:Socket #1: L1N=236.2V L2N=236.5V L3N=236.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:42:21.578Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-08T01:42:35.667Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T01:43:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:44:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:44:33.703Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-08T01:45:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T01:45:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:46:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:47:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:47:05.335Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-08T01:47:05.343Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-08T01:47:05.355Z:USER:taskMaster.c:6684:Socket #1: L1N=235.9V L2N=236.6V L3N=236.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:47:05.367Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-08T01:47:05.375Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-08T01:47:05.386Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-08T01:47:05.394Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-08T01:47:05.582Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-08T01:47:06.359Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-08T01:47:11.640Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.9 due to current limit: ChargingProfile
2025-11-08T01:47:11.683Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-08T01:47:12.421Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-08T01:47:35.382Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.7V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:47:35.394Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-11-08T01:47:59.636Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.4 due to current limit: Active-LoadBalancing
2025-11-08T01:47:59.648Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->25.6)
2025-11-08T01:47:59.679Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-08T01:47:59.886Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.6% (15.4 A)
2025-11-08T01:48:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:48:05.343Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-08T01:48:05.378Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.7V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:48:05.390Z:USER:taskMaster.c:6720:Socket #1: I1=14.9A I2=14.9A I3=14.9A P=10.5kW Idc=0.7mA
2025-11-08T01:48:11.632Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:48:11.648Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.6->24.6)
2025-11-08T01:48:12.003Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.6% (14.8 A)
2025-11-08T01:48:23.632Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:48:23.644Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T01:48:35.375Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.4V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:48:35.386Z:USER:taskMaster.c:6720:Socket #1: I1=14.1A I2=14.1A I3=14.0A P=9.9kW Idc=0.7mA
2025-11-08T01:48:35.632Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T01:48:35.644Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->23.9)
2025-11-08T01:48:47.628Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:48:59.628Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->15.0 due to current limit: Active-LoadBalancing
2025-11-08T01:49:00.480Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.9% (14.9 A)
2025-11-08T01:49:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:49:05.371Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.4V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:49:05.386Z:USER:taskMaster.c:6720:Socket #1: I1=14.6A I2=14.6A I3=14.5A P=10.2kW Idc=0.7mA
2025-11-08T01:49:11.628Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-08T01:49:23.625Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-08T01:49:23.640Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-08T01:49:35.371Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.4V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:49:35.382Z:USER:taskMaster.c:6720:Socket #1: I1=14.6A I2=14.7A I3=14.5A P=10.2kW Idc=0.7mA
2025-11-08T01:49:35.625Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T01:49:35.636Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T01:49:47.625Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T01:49:47.636Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T01:49:59.621Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:49:59.636Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T01:50:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:50:05.367Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.5V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:50:05.378Z:USER:taskMaster.c:6720:Socket #1: I1=14.1A I2=14.1A I3=14.1A P=9.9kW Idc=0.7mA
2025-11-08T01:50:11.621Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:50:23.621Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-08T01:50:35.363Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.3V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:50:35.375Z:USER:taskMaster.c:6720:Socket #1: I1=14.6A I2=14.6A I3=14.6A P=10.2kW Idc=0.7mA
2025-11-08T01:50:35.621Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-08T01:50:47.617Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-08T01:50:47.628Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-08T01:50:59.617Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T01:50:59.628Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T01:51:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:51:05.359Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.3V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:51:05.371Z:USER:taskMaster.c:6720:Socket #1: I1=14.4A I2=14.5A I3=14.4A P=10.1kW Idc=0.7mA
2025-11-08T01:51:11.617Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T01:51:11.628Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T01:51:23.613Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:51:23.625Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-08T01:51:35.355Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.4V L3N=234.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:51:35.367Z:USER:taskMaster.c:6720:Socket #1: I1=14.1A I2=14.1A I3=14.1A P=9.9kW Idc=0.7mA
2025-11-08T01:51:35.613Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:51:47.613Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-08T01:51:59.609Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-08T01:52:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:52:05.355Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.3V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:52:05.367Z:USER:taskMaster.c:6720:Socket #1: I1=14.8A I2=14.8A I3=14.8A P=10.4kW Idc=0.7mA
2025-11-08T01:52:05.375Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-08T01:52:11.609Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-08T01:52:11.621Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-08T01:52:23.609Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T01:52:23.621Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T01:52:35.605Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T01:52:35.621Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T01:52:47.605Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:52:47.617Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T01:52:59.605Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:53:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:53:11.601Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-08T01:53:23.601Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-08T01:53:35.601Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-08T01:53:35.613Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-08T01:53:47.597Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T01:53:47.613Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T01:53:59.597Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T01:53:59.609Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T01:54:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:54:11.597Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:54:11.609Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T01:54:23.593Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:54:33.636Z:INFO:active_lb.c:308:SMt:(14.0 15.0 15.0)A Free:(2.0 1.0 1.0)A ALB:(15.3 14.8 15.3)A
2025-11-08T01:54:34.089Z:USER:taskMaster.c:6582:Temperature: 26.0 C
2025-11-08T01:54:35.593Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T01:54:47.593Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T01:54:47.605Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T01:54:59.589Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T01:54:59.605Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T01:55:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:55:11.589Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:55:11.601Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T01:55:23.589Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:55:32.632Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-08T01:55:32.640Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-08T01:55:32.652Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-08T01:55:32.660Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-08T01:55:33.316Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-08T01:55:33.636Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-08T01:55:35.585Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->9.3 due to current limit: Active-LoadBalancing
2025-11-08T01:55:35.656Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.4% (9.2 A)
2025-11-08T01:55:47.585Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->6.0 due to current limit: Active-LoadBalancing
2025-11-08T01:55:47.597Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.97) < minimum current(6.00)
2025-11-08T01:55:47.628Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-08T01:55:47.640Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-08T01:55:47.648Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-08T01:55:47.777Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-08T01:55:48.625Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-11-08T01:55:48.625Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-08T01:55:59.585Z:INFO:taskMain.c:5996:Socket #1: Active current 6.0->9.6 due to current limit: Active-LoadBalancing
2025-11-08T01:55:59.628Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-08T01:55:59.640Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-08T01:55:59.648Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-08T01:55:59.734Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-08T01:56:00.632Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-08T01:56:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:56:11.582Z:INFO:taskMain.c:5996:Socket #1: Active current 9.6->11.8 due to current limit: Active-LoadBalancing
2025-11-08T01:56:11.742Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.5% (11.7 A)
2025-11-08T01:56:23.582Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->13.1 due to current limit: Active-LoadBalancing
2025-11-08T01:56:23.863Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.7% (13.0 A)
2025-11-08T01:56:29.675Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-08T01:56:29.683Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-08T01:56:29.921Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-08T01:56:29.929Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-08T01:56:30.671Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-08T01:56:33.675Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-08T01:56:33.703Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-08T01:56:33.707Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-08T01:56:34.175Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-08T01:56:34.183Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-08T01:56:34.710Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-08T01:56:35.199Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-08T01:56:35.582Z:INFO:taskMain.c:5996:Socket #1: Active current 13.1->13.8 due to current limit: Active-LoadBalancing
2025-11-08T01:56:36.210Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-08T01:56:47.578Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->14.3 due to current limit: Active-LoadBalancing
2025-11-08T01:56:48.328Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.8% (14.3 A)
2025-11-08T01:56:59.578Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:57:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:57:11.578Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-11-08T01:57:23.574Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:57:33.019Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-08T01:57:33.027Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-08T01:57:33.039Z:USER:taskMaster.c:6684:Socket #1: L1N=235.4V L2N=236.0V L3N=235.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:57:33.050Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-08T01:57:33.058Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-08T01:57:33.070Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-08T01:57:33.078Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-08T01:57:33.773Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-08T01:57:34.035Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-08T01:57:35.574Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T01:57:47.574Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.9 due to current limit: ChargingProfile
2025-11-08T01:57:47.617Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-08T01:57:48.171Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-08T01:58:03.066Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=234.3V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:58:03.078Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-11-08T01:58:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:58:33.019Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-08T01:58:33.062Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.3V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:58:33.074Z:USER:taskMaster.c:6720:Socket #1: I1=15.5A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-11-08T01:58:35.570Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.5 due to current limit: Active-LoadBalancing
2025-11-08T01:58:35.582Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->25.8)
2025-11-08T01:58:35.613Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-08T01:58:35.636Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.8% (15.5 A)
2025-11-08T01:58:47.566Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->14.9 due to current limit: Active-LoadBalancing
2025-11-08T01:58:47.578Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.8->24.8)
2025-11-08T01:58:47.757Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.8% (14.9 A)
2025-11-08T01:58:59.566Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-08T01:58:59.578Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.6)
2025-11-08T01:59:03.058Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.4V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:59:03.070Z:USER:taskMaster.c:6720:Socket #1: I1=14.3A I2=14.4A I3=14.3A P=10.0kW Idc=0.7mA
2025-11-08T01:59:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T01:59:11.566Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T01:59:11.578Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T01:59:23.562Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T01:59:23.574Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T01:59:33.054Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.5V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T01:59:33.070Z:USER:taskMaster.c:6720:Socket #1: I1=14.0A I2=14.1A I3=14.0A P=9.8kW Idc=0.7mA
2025-11-08T01:59:35.562Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-08T01:59:35.574Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.7)
2025-11-08T01:59:47.562Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-08T01:59:59.558Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-08T01:59:59.574Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.7)
2025-11-08T02:00:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T02:00:03.054Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.8V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T02:00:03.066Z:USER:taskMaster.c:6720:Socket #1: I1=13.8A I2=13.9A I3=13.8A P=9.7kW Idc=0.7mA
2025-11-08T02:00:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:00:11.558Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-08T02:00:22.753Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-08T02:00:22.765Z:INFO:db_chargingprofi:26: socket 0
2025-11-08T02:00:22.773Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-08T02:00:22.781Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-08T02:00:22.789Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-08T02:00:22.796Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-08T02:00:22.808Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-08T02:00:22.816Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-08T02:00:22.824Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-08T02:00:22.832Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-08T02:00:22.839Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-08T02:00:22.847Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-08T02:00:22.855Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-08T02:00:22.863Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-08T02:00:22.871Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-08T02:00:22.882Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-08T02:00:22.890Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-08T02:00:22.898Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-08T02:00:22.910Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-08T02:00:22.917Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-08T02:00:22.925Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-08T02:00:22.933Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-08T02:00:22.941Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-08T02:00:23.558Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:00:33.050Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.5V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T02:00:33.062Z:USER:taskMaster.c:6720:Socket #1: I1=14.3A I2=14.3A I3=14.3A P=10.0kW Idc=0.7mA
2025-11-08T02:00:35.554Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.1 due to current limit: Active-LoadBalancing
2025-11-08T02:00:35.804Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.2% (15.1 A)
2025-11-08T02:00:47.554Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.4 due to current limit: Active-LoadBalancing
2025-11-08T02:00:59.554Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.2 due to current limit: Active-LoadBalancing
2025-11-08T02:00:59.566Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.6->25.3)
2025-11-08T02:01:03.046Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.2V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T02:01:03.058Z:USER:taskMaster.c:6720:Socket #1: I1=14.7A I2=14.8A I3=14.7A P=10.3kW Idc=0.7mA
2025-11-08T02:01:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:01:11.550Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.1 due to current limit: Active-LoadBalancing
2025-11-08T02:01:11.566Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.1)
2025-11-08T02:01:23.550Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:01:23.562Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T02:01:33.093Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.2V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T02:01:33.109Z:USER:taskMaster.c:6720:Socket #1: I1=14.5A I2=14.5A I3=14.5A P=10.2kW Idc=0.7mA
2025-11-08T02:01:35.550Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:01:35.562Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T02:01:47.546Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:01:47.562Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T02:01:59.546Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:01:59.558Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T02:02:03.140Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.3V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T02:02:03.152Z:USER:taskMaster.c:6720:Socket #1: I1=14.0A I2=14.1A I3=14.0A P=9.8kW Idc=0.7mA
2025-11-08T02:02:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:02:11.546Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T02:02:11.558Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-08T02:02:23.542Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-08T02:02:23.558Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-08T02:02:33.136Z:USER:taskMaster.c:6684:Socket #1: L1N=233.5V L2N=234.2V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T02:02:33.148Z:USER:taskMaster.c:6720:Socket #1: I1=13.7A I2=13.8A I3=13.7A P=9.6kW Idc=0.7mA
2025-11-08T02:02:33.160Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-08T02:02:35.542Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:02:47.542Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:02:59.539Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:03:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:03:11.539Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:03:11.550Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T02:03:23.539Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:03:23.550Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T02:03:35.535Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:03:35.550Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T02:03:47.535Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T02:03:47.546Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-08T02:03:59.535Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-08T02:04:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:04:11.531Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:04:23.531Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:04:23.542Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-08T02:04:33.574Z:INFO:active_lb.c:308:SMt:(15.0 16.0 15.0)A Free:(1.0 0.0 1.0)A ALB:(16.1 14.6 15.2)A
2025-11-08T02:04:35.531Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-08T02:04:35.542Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T02:04:47.527Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-08T02:04:47.542Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-08T02:04:59.527Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:05:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:05:11.527Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:05:23.527Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:05:23.539Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-08T02:05:35.523Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-08T02:05:35.535Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-08T02:05:47.523Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:05:47.535Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-08T02:05:59.523Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-08T02:05:59.535Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.7)
2025-11-08T02:06:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:06:11.519Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-08T02:06:23.519Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:06:35.519Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:06:47.515Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:06:47.531Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-08T02:06:59.515Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:06:59.527Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-08T02:07:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:07:11.515Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-08T02:07:11.527Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-08T02:07:23.511Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:07:23.527Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-08T02:07:35.511Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-08T02:07:35.523Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.7)
2025-11-08T02:07:47.511Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-08T02:07:59.507Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:08:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:08:11.507Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:08:23.507Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:08:23.519Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T02:08:35.503Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:08:35.519Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T02:08:47.503Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:08:47.515Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T02:08:59.503Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:08:59.515Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T02:09:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:09:11.500Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T02:09:11.515Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-08T02:09:23.500Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-08T02:09:34.394Z:USER:taskMaster.c:6582:Temperature: 27.1 C
2025-11-08T02:09:35.500Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:09:47.496Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:09:47.511Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-08T02:09:59.496Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-08T02:09:59.507Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T02:10:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:10:11.496Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-08T02:10:11.507Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-08T02:10:23.492Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:10:35.492Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:10:47.492Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:10:47.503Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-08T02:10:59.488Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-08T02:10:59.503Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T02:11:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:11:11.488Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-08T02:11:11.500Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.9)
2025-11-08T02:11:23.488Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-08T02:11:23.500Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.9->23.6)
2025-11-08T02:11:35.484Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:11:47.484Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:11:59.484Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:12:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:12:11.484Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:12:11.496Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T02:12:23.480Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:12:23.492Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T02:12:35.480Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:12:35.492Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T02:12:47.480Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T02:12:47.492Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-08T02:12:59.476Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-08T02:13:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:13:11.476Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:13:23.476Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:13:23.488Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T02:13:35.472Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:13:35.484Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T02:13:47.472Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T02:13:47.484Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-08T02:13:59.472Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-08T02:13:59.484Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-08T02:14:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:14:11.468Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:14:23.468Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:14:33.511Z:INFO:active_lb.c:308:SMt:(14.0 15.0 14.0)A Free:(2.0 1.0 2.0)A ALB:(15.9 14.7 15.4)A
2025-11-08T02:14:35.468Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:14:47.464Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:14:47.480Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T02:14:59.464Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:14:59.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T02:15:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T02:15:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:15:11.464Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:15:11.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T02:15:23.460Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T02:15:23.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-08T02:15:35.460Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-08T02:15:47.460Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:15:59.457Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:15:59.472Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T02:16:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:16:11.457Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:16:11.468Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T02:16:23.457Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T02:16:23.468Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-08T02:16:35.453Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:16:47.453Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:16:59.453Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:17:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:17:11.449Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-08T02:17:23.449Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-08T02:17:23.460Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.2)
2025-11-08T02:17:33.042Z:USER:taskMaster.c:6684:Socket #1: L1N=233.3V L2N=233.8V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T02:17:33.054Z:USER:taskMaster.c:6720:Socket #1: I1=14.8A I2=14.8A I3=14.8A P=10.3kW Idc=0.7mA
2025-11-08T02:17:35.449Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:17:35.460Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-08T02:17:47.445Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:17:47.460Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-08T02:17:59.445Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:17:59.457Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-08T02:18:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:18:11.445Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:18:11.457Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T02:18:23.441Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:18:35.441Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T02:18:47.441Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:18:47.453Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T02:18:59.437Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:18:59.453Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.6)
2025-11-08T02:19:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:19:11.437Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:19:11.449Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T02:19:23.437Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:19:35.437Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T02:19:47.433Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:19:47.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T02:19:59.433Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:19:59.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.6)
2025-11-08T02:20:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:20:11.433Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:20:11.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T02:20:23.429Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:20:35.429Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T02:20:47.429Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:20:47.441Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-08T02:20:59.425Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:20:59.441Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-08T02:21:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:21:11.425Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:21:11.437Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T02:21:23.425Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:21:35.421Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-08T02:21:47.421Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:21:47.433Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-08T02:21:59.421Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:21:59.433Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-08T02:22:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:22:11.417Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:22:11.433Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T02:22:23.417Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:22:35.417Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-08T02:22:47.414Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:22:47.429Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-08T02:22:59.414Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:22:59.425Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-08T02:23:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:23:11.414Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:23:11.425Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T02:23:23.410Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:23:35.410Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:23:35.421Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-08T02:23:47.410Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:23:47.421Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-08T02:23:59.406Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:23:59.421Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-08T02:24:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:24:05.000Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000025, address 0x00025000 (1)
2025-11-08T02:24:05.011Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-08T02:24:11.406Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:24:23.406Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:24:33.449Z:INFO:active_lb.c:308:SMt:(15.0 15.0 15.0)A Free:(1.0 1.0 1.0)A ALB:(14.8 15.1 15.1)A
2025-11-08T02:24:34.796Z:USER:taskMaster.c:6582:Temperature: 28.4 C
2025-11-08T02:24:35.402Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T02:24:47.402Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:24:47.414Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T02:24:59.402Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:24:59.414Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T02:25:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:25:11.398Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:25:11.414Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-08T02:25:23.398Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:25:23.410Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->23.9)
2025-11-08T02:25:35.398Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:25:47.394Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:25:47.605Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.0% (15.0 A)
2025-11-08T02:25:59.394Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-08T02:26:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:26:11.394Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.2 due to current limit: Active-LoadBalancing
2025-11-08T02:26:11.406Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->25.2)
2025-11-08T02:26:23.394Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:26:23.406Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->25.0)
2025-11-08T02:26:35.390Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:26:35.402Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T02:26:47.390Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:26:47.402Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T02:26:59.390Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:26:59.402Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T02:27:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:27:11.386Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:27:23.386Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T02:27:35.386Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.3 due to current limit: Active-LoadBalancing
2025-11-08T02:27:47.382Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.2 due to current limit: Active-LoadBalancing
2025-11-08T02:27:47.394Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->25.3)
2025-11-08T02:27:59.382Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:27:59.394Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-08T02:28:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:28:11.382Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:28:11.394Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T02:28:23.378Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:28:23.394Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T02:28:35.378Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:28:35.390Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T02:28:47.378Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:28:59.375Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T02:29:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:29:11.375Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:29:11.386Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-08T02:29:23.375Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:29:23.386Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-08T02:29:35.371Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:29:35.386Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T02:29:47.371Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-08T02:29:47.382Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.1)
2025-11-08T02:29:59.371Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:30:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T02:30:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:30:11.367Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:30:23.367Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.8)
2025-11-08T02:30:35.367Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:30:35.378Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.4)
2025-11-08T02:30:47.363Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-08T02:30:47.378Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T02:30:59.363Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-08T02:30:59.375Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-08T02:31:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:31:11.363Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-08T02:31:23.359Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:31:35.359Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.2 due to current limit: Active-LoadBalancing
2025-11-08T02:31:36.019Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.2% (15.1 A)
2025-11-08T02:31:47.359Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:31:47.371Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->25.0)
2025-11-08T02:31:59.355Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:31:59.371Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T02:32:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:32:11.355Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:32:11.367Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T02:32:23.355Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:32:23.367Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T02:32:32.949Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=234.2V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T02:32:32.960Z:USER:taskMaster.c:6720:Socket #1: I1=14.2A I2=14.2A I3=14.2A P=10.0kW Idc=0.7mA
2025-11-08T02:32:35.351Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:32:35.367Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T02:32:47.351Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:32:59.351Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:33:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:33:11.347Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-08T02:33:23.347Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:33:23.359Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-08T02:33:35.347Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:33:35.359Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-08T02:33:47.347Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:33:47.359Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-08T02:33:59.343Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-08T02:33:59.355Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.2)
2025-11-08T02:34:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:34:11.343Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:34:23.343Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:34:33.386Z:INFO:active_lb.c:308:SMt:(14.0 15.0 15.0)A Free:(2.0 1.0 1.0)A ALB:(16.0 15.0 15.3)A
2025-11-08T02:34:35.339Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-08T02:34:47.339Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.2 due to current limit: Active-LoadBalancing
2025-11-08T02:34:47.351Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->25.2)
2025-11-08T02:34:59.339Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:34:59.351Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->25.0)
2025-11-08T02:35:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:35:11.335Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:35:11.347Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.7)
2025-11-08T02:35:23.335Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:35:23.347Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-08T02:35:35.335Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:35:35.347Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T02:35:47.332Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:35:47.347Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T02:35:59.332Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:36:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:36:11.332Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:36:23.328Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-08T02:36:35.328Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.5 due to current limit: Active-LoadBalancing
2025-11-08T02:36:47.328Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.3 due to current limit: Active-LoadBalancing
2025-11-08T02:36:47.339Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->25.5)
2025-11-08T02:36:55.218Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-08T02:36:55.230Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-08T02:36:55.238Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-08T02:36:55.246Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-08T02:36:56.164Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-08T02:36:56.246Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-08T02:36:59.324Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->9.2 due to current limit: Active-LoadBalancing
2025-11-08T02:37:00.285Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.3% (9.2 A)
2025-11-08T02:37:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:37:11.324Z:INFO:taskMain.c:5996:Socket #1: Active current 9.2->5.5 due to current limit: Active-LoadBalancing
2025-11-08T02:37:11.335Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.51) < minimum current(6.00)
2025-11-08T02:37:11.367Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-08T02:37:11.378Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-08T02:37:11.386Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-08T02:37:11.398Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-08T02:37:12.363Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-11-08T02:37:12.363Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-08T02:37:23.324Z:INFO:taskMain.c:5996:Socket #1: Active current 5.5->9.3 due to current limit: Active-LoadBalancing
2025-11-08T02:37:23.367Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-08T02:37:23.375Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-08T02:37:23.386Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-08T02:37:23.472Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-08T02:37:24.371Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-08T02:37:35.320Z:INFO:taskMain.c:5996:Socket #1: Active current 9.3->11.6 due to current limit: Active-LoadBalancing
2025-11-08T02:37:35.480Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.3% (11.6 A)
2025-11-08T02:37:47.320Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->13.0 due to current limit: Active-LoadBalancing
2025-11-08T02:37:47.601Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.5% (12.9 A)
2025-11-08T02:37:53.414Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-08T02:37:53.421Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-08T02:37:53.660Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-08T02:37:53.667Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-08T02:37:54.410Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-08T02:37:57.414Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-08T02:37:57.437Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-08T02:37:57.445Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-08T02:37:57.914Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-08T02:37:57.921Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-08T02:37:58.449Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-08T02:37:58.937Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-08T02:37:59.320Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.8 due to current limit: Active-LoadBalancing
2025-11-08T02:37:59.949Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.9% (13.7 A)
2025-11-08T02:38:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:38:11.316Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->14.3 due to current limit: Active-LoadBalancing
2025-11-08T02:38:12.066Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.7% (14.2 A)
2025-11-08T02:38:23.316Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:38:35.316Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:38:47.312Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:39:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:39:11.312Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:39:35.203Z:USER:taskMaster.c:6582:Temperature: 29.0 C
2025-11-08T02:40:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:41:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:42:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:43:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:44:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:44:10.671Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-08T02:44:10.683Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-08T02:44:10.691Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=235.9V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T02:44:10.703Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-08T02:44:10.714Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-08T02:44:10.722Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-08T02:44:10.734Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-08T02:44:11.589Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-08T02:44:11.699Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-08T02:44:23.277Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.9 due to current limit: ChargingProfile
2025-11-08T02:44:23.324Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-08T02:44:23.820Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-08T02:44:33.320Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(20.8 20.8 20.8)A
2025-11-08T02:44:40.722Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=234.2V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T02:44:40.734Z:USER:taskMaster.c:6720:Socket #1: I1=15.6A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-11-08T02:45:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T02:45:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:45:10.683Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-08T02:45:10.718Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.5V L3N=234.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T02:45:10.730Z:USER:taskMaster.c:6720:Socket #1: I1=15.6A I2=15.6A I3=15.5A P=10.9kW Idc=0.7mA
2025-11-08T02:45:35.269Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.4 due to current limit: Active-LoadBalancing
2025-11-08T02:45:35.285Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->25.6)
2025-11-08T02:45:35.316Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-08T02:45:35.519Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.6% (15.4 A)
2025-11-08T02:45:40.714Z:USER:taskMaster.c:6684:Socket #1: L1N=233.3V L2N=234.1V L3N=234.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T02:45:40.726Z:USER:taskMaster.c:6720:Socket #1: I1=14.9A I2=15.0A I3=14.9A P=10.5kW Idc=0.7mA
2025-11-08T02:45:47.269Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:45:47.281Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.6->24.6)
2025-11-08T02:45:47.640Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.6% (14.8 A)
2025-11-08T02:45:59.269Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:45:59.281Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T02:46:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:46:10.710Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.2V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T02:46:10.722Z:USER:taskMaster.c:6720:Socket #1: I1=14.1A I2=14.2A I3=14.2A P=9.9kW Idc=0.7mA
2025-11-08T02:46:11.265Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:46:11.281Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T02:46:23.265Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:46:35.265Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:46:40.707Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.4V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T02:46:40.718Z:USER:taskMaster.c:6720:Socket #1: I1=14.4A I2=14.5A I3=14.4A P=10.1kW Idc=0.7mA
2025-11-08T02:46:47.261Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-08T02:46:59.261Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:46:59.273Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-08T02:47:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:47:10.703Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.5V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T02:47:10.718Z:USER:taskMaster.c:6720:Socket #1: I1=14.6A I2=14.6A I3=14.5A P=10.2kW Idc=0.7mA
2025-11-08T02:47:11.261Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:47:11.273Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-08T02:47:23.257Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:47:23.273Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-08T02:47:35.257Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-08T02:47:35.269Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T02:47:40.703Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.9V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T02:47:40.714Z:USER:taskMaster.c:6720:Socket #1: I1=14.1A I2=14.1A I3=14.0A P=9.9kW Idc=0.7mA
2025-11-08T02:47:47.257Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-08T02:47:47.269Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-08T02:47:59.253Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:48:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:48:10.699Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.6V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T02:48:10.710Z:USER:taskMaster.c:6720:Socket #1: I1=14.1A I2=14.2A I3=14.2A P=9.9kW Idc=0.7mA
2025-11-08T02:48:11.253Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:48:23.253Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:48:35.253Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-08T02:48:40.695Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.7V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T02:48:40.707Z:USER:taskMaster.c:6720:Socket #1: I1=14.8A I2=14.9A I3=14.9A P=10.4kW Idc=0.7mA
2025-11-08T02:48:47.250Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-08T02:48:47.261Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.0)
2025-11-08T02:48:59.250Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:48:59.261Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.7)
2025-11-08T02:49:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:49:10.691Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=234.9V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T02:49:10.703Z:USER:taskMaster.c:6720:Socket #1: I1=14.4A I2=14.5A I3=14.4A P=10.1kW Idc=0.7mA
2025-11-08T02:49:10.714Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-08T02:49:23.246Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:49:23.257Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-08T02:49:35.246Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:49:35.257Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-08T02:49:47.246Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:49:47.257Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->24.0)
2025-11-08T02:49:59.242Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:50:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:50:11.242Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:50:23.242Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-08T02:50:35.238Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.4 due to current limit: Active-LoadBalancing
2025-11-08T02:50:47.238Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.2 due to current limit: Active-LoadBalancing
2025-11-08T02:50:47.250Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.6->25.3)
2025-11-08T02:50:59.238Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:50:59.250Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-08T02:51:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:51:11.234Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:51:11.250Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T02:51:23.234Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:51:23.246Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T02:51:35.234Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:51:35.246Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-08T02:51:47.230Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->13.6 due to current limit: Active-LoadBalancing
2025-11-08T02:51:47.246Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->22.7)
2025-11-08T02:51:48.171Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.7% (13.6 A)
2025-11-08T02:51:59.230Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.9 due to current limit: Active-LoadBalancing
2025-11-08T02:52:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:52:11.230Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->14.2 due to current limit: Active-LoadBalancing
2025-11-08T02:52:23.226Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:52:35.226Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:52:47.226Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:52:59.222Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-08T02:53:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:53:11.222Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:53:11.234Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-08T02:53:23.222Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T02:53:23.234Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-08T02:53:35.218Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:53:35.234Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T02:53:47.218Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:53:47.230Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T02:53:59.218Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T02:53:59.230Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-08T02:54:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:54:11.214Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-08T02:54:23.214Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:54:33.257Z:INFO:active_lb.c:308:SMt:(14.0 15.0 14.0)A Free:(2.0 1.0 2.0)A ALB:(15.7 14.7 15.5)A
2025-11-08T02:54:35.214Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:54:35.558Z:USER:taskMaster.c:6582:Temperature: 28.6 C
2025-11-08T02:54:47.210Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-08T02:54:59.210Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:54:59.222Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-08T02:55:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:55:11.210Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:55:11.222Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T02:55:23.207Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:55:23.222Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T02:55:35.207Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:55:35.218Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-08T02:55:47.207Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:55:47.218Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->24.0)
2025-11-08T02:55:59.207Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T02:55:59.218Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.7)
2025-11-08T02:56:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:56:11.203Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-08T02:56:23.203Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:56:35.203Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:56:47.199Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-08T02:56:59.199Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:56:59.210Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-08T02:57:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:57:11.199Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:57:11.210Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.7)
2025-11-08T02:57:23.195Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:57:23.210Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-08T02:57:35.195Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:57:35.207Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T02:57:47.195Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:57:47.207Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T02:57:59.191Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T02:57:59.207Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.7)
2025-11-08T02:58:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:58:11.191Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-08T02:58:23.191Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:58:35.187Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:58:47.187Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-08T02:58:59.187Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-08T02:58:59.199Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-08T02:59:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T02:59:11.183Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T02:59:11.199Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T02:59:23.183Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T02:59:23.195Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T02:59:35.183Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T02:59:35.195Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-08T02:59:47.179Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T02:59:47.195Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.2->24.0)
2025-11-08T02:59:59.179Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T02:59:59.191Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.7)
2025-11-08T03:00:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T03:00:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:00:11.179Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:00:23.175Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:00:30.222Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-08T03:00:30.234Z:INFO:db_chargingprofi:26: socket 0
2025-11-08T03:00:30.242Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-08T03:00:30.250Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-08T03:00:30.257Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-08T03:00:30.265Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-08T03:00:30.277Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-08T03:00:30.285Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-08T03:00:30.292Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-08T03:00:30.300Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-08T03:00:30.308Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-08T03:00:30.316Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-08T03:00:30.324Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-08T03:00:30.335Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-08T03:00:30.339Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-08T03:00:30.351Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-08T03:00:30.359Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-08T03:00:30.367Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-08T03:00:30.378Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-08T03:00:30.386Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-08T03:00:30.394Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-08T03:00:30.402Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-08T03:00:30.410Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-08T03:00:35.175Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:00:47.175Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:00:47.187Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-08T03:00:59.171Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:00:59.187Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-08T03:01:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:01:11.171Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:01:11.183Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T03:01:23.171Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-08T03:01:23.183Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.9)
2025-11-08T03:01:35.167Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:01:47.167Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:01:59.167Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:01:59.179Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-08T03:02:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:02:11.164Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:02:11.179Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T03:02:23.164Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-08T03:02:23.175Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-08T03:02:35.164Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:02:47.160Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:02:59.160Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:02:59.171Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T03:03:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:03:11.160Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:03:11.171Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T03:03:23.160Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T03:03:23.171Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-08T03:03:35.156Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:03:47.156Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:03:59.156Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:03:59.167Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T03:04:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:04:10.597Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=234.5V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T03:04:10.609Z:USER:taskMaster.c:6720:Socket #1: I1=14.2A I2=14.2A I3=14.1A P=10.0kW Idc=0.7mA
2025-11-08T03:04:11.152Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:04:11.164Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T03:04:23.152Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T03:04:23.164Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-08T03:04:33.195Z:INFO:active_lb.c:308:SMt:(14.0 15.0 15.0)A Free:(2.0 1.0 1.0)A ALB:(16.1 14.3 15.2)A
2025-11-08T03:04:35.152Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:04:47.148Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:04:59.148Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:04:59.160Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T03:05:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:05:11.148Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:05:11.160Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T03:05:23.144Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T03:05:23.160Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-08T03:05:35.144Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:05:47.144Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:05:59.140Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:05:59.156Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T03:06:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:06:11.140Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:06:11.152Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T03:06:23.140Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T03:06:23.152Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-08T03:06:35.136Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:06:47.136Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:06:59.136Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:07:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:07:11.132Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:07:11.148Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T03:07:23.132Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:07:23.144Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:07:35.132Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:07:35.144Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T03:07:47.128Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:07:59.128Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:08:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:08:11.128Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:08:11.140Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T03:08:23.125Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:08:23.140Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:08:35.125Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:08:35.136Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T03:08:47.125Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:08:59.121Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T03:09:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:09:11.121Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:09:11.132Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T03:09:23.121Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:09:23.132Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:09:35.117Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:09:35.132Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T03:09:35.914Z:USER:taskMaster.c:6582:Temperature: 29.5 C
2025-11-08T03:09:47.117Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:09:59.117Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T03:10:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:10:11.113Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:10:11.128Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T03:10:23.113Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:10:23.125Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:10:35.164Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:10:35.175Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T03:10:47.160Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:10:59.160Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T03:11:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:11:11.160Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:11:11.171Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T03:11:23.156Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:11:23.171Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:11:35.156Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:11:35.167Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T03:11:47.156Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:11:59.152Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:12:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:12:11.152Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-08T03:12:23.152Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-08T03:12:23.164Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.2)
2025-11-08T03:12:35.148Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:12:35.164Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-08T03:12:47.148Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:12:47.160Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-08T03:12:59.148Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:12:59.160Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-08T03:13:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:13:11.144Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:13:23.144Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-08T03:13:35.144Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:13:35.156Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-08T03:13:47.140Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:13:47.156Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-08T03:13:59.140Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:13:59.152Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T03:14:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:14:11.140Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:14:23.136Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T03:14:33.132Z:INFO:active_lb.c:308:SMt:(15.0 16.0 15.0)A Free:(1.0 0.0 1.0)A ALB:(16.1 15.1 15.3)A
2025-11-08T03:14:35.136Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:14:35.148Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T03:14:47.136Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:14:47.148Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:14:59.132Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:14:59.148Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T03:15:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T03:15:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:15:11.132Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.2)
2025-11-08T03:15:23.132Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:15:35.132Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:15:47.128Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:15:47.140Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-08T03:15:59.128Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:15:59.140Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T03:16:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:16:11.128Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:16:11.140Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->23.9)
2025-11-08T03:16:23.125Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:16:23.636Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.9% (14.9 A)
2025-11-08T03:16:35.125Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-08T03:16:47.125Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:16:47.136Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-08T03:16:59.121Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:16:59.132Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T03:17:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:17:11.121Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:17:11.132Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:17:23.121Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:17:23.132Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-08T03:17:35.117Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:17:47.117Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:17:59.117Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-08T03:18:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:18:11.113Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-08T03:18:11.128Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-08T03:18:23.113Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:18:23.125Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T03:18:35.113Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:18:35.125Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:18:47.109Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:18:47.125Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T03:18:59.109Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:19:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:19:10.503Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.7V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T03:19:10.519Z:USER:taskMaster.c:6720:Socket #1: I1=14.3A I2=14.3A I3=14.3A P=10.1kW Idc=0.7mA
2025-11-08T03:19:11.109Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:19:23.105Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:19:23.121Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T03:19:35.105Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:19:35.117Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:19:47.105Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:19:47.117Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T03:19:59.101Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:20:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:20:11.101Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:20:23.101Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:20:23.113Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-08T03:20:35.097Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:20:35.113Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T03:20:47.097Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:20:47.109Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T03:20:59.097Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:21:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:21:11.093Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->15.1 due to current limit: Active-LoadBalancing
2025-11-08T03:21:11.457Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.1% (15.1 A)
2025-11-08T03:21:23.093Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:21:23.105Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T03:21:35.093Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:21:35.105Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:21:47.089Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:21:47.105Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T03:21:59.089Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:22:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:22:11.089Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T03:22:23.085Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:22:23.101Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T03:22:35.085Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:22:35.097Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:22:47.085Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:22:47.097Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T03:22:59.082Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:23:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:23:11.082Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T03:23:23.082Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:23:23.093Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T03:23:35.082Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:23:35.093Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:23:47.078Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:23:47.089Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T03:23:59.078Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:23:59.089Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T03:24:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:24:11.078Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:24:23.074Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:24:33.066Z:INFO:active_lb.c:308:SMt:(14.0 15.0 15.0)A Free:(2.0 1.0 1.0)A ALB:(15.9 14.9 15.2)A
2025-11-08T03:24:35.074Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-08T03:24:36.269Z:USER:taskMaster.c:6582:Temperature: 29.8 C
2025-11-08T03:24:47.074Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:24:47.085Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-08T03:24:59.070Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:24:59.082Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-08T03:25:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:25:04.113Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000026, address 0x00026000 (1)
2025-11-08T03:25:04.125Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-08T03:25:11.070Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:25:11.082Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-08T03:25:23.070Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:25:23.082Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T03:25:35.066Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:25:47.066Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:25:59.066Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:25:59.078Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-08T03:26:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:26:11.062Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:26:11.078Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-08T03:26:23.062Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:26:23.074Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T03:26:35.062Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:26:47.058Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:26:59.058Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-08T03:27:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:27:11.058Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:27:11.070Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-08T03:27:23.054Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:27:23.070Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T03:27:35.054Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:27:35.066Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:27:47.054Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:27:47.066Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T03:27:59.050Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:27:59.066Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T03:28:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:28:11.050Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:28:23.050Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:28:35.046Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-08T03:28:47.046Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:28:47.058Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-08T03:28:59.046Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:28:59.058Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-08T03:29:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:29:11.042Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:29:11.058Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-08T03:29:23.042Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:29:23.054Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T03:29:35.042Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:29:47.039Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:29:59.039Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:29:59.050Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-08T03:30:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T03:30:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:30:11.039Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:30:11.050Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-08T03:30:23.035Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:30:23.050Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T03:30:35.035Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:30:47.035Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:30:59.031Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-08T03:31:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:31:11.031Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:31:11.042Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-08T03:31:23.031Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:31:23.042Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T03:31:35.031Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:31:35.042Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:31:47.027Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:31:47.039Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-08T03:32:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:32:11.027Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:32:11.039Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T03:32:23.023Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-08T03:32:23.035Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-08T03:32:35.023Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:32:35.164Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.8% (14.9 A)
2025-11-08T03:32:47.023Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.2 due to current limit: Active-LoadBalancing
2025-11-08T03:32:59.019Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:32:59.031Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->25.0)
2025-11-08T03:33:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:33:11.019Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:33:11.031Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.7)
2025-11-08T03:33:23.019Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:33:23.031Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.5)
2025-11-08T03:33:35.015Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:33:35.031Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.2)
2025-11-08T03:33:47.015Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:33:59.015Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:34:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:34:10.406Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=234.8V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T03:34:10.417Z:USER:taskMaster.c:6720:Socket #1: I1=14.7A I2=14.7A I3=14.7A P=10.3kW Idc=0.7mA
2025-11-08T03:34:11.011Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-08T03:34:23.011Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-08T03:34:23.023Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.2)
2025-11-08T03:34:24.605Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-08T03:34:24.613Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-08T03:34:33.003Z:INFO:active_lb.c:308:SMt:(15.0 16.0 15.0)A Free:(1.0 0.0 1.0)A ALB:(15.8 15.1 15.2)A
2025-11-08T03:34:35.011Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:34:35.023Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-08T03:34:47.007Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:34:47.023Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-08T03:34:59.007Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:34:59.019Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T03:35:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:35:11.007Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:35:11.019Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T03:35:23.003Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:35:35.003Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:35:47.003Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-08T03:35:59.000Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:35:59.015Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-08T03:36:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:36:11.000Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:36:11.011Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-08T03:36:23.000Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:36:23.011Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-08T03:36:34.996Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:36:35.011Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T03:36:46.996Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:36:58.996Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:37:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:37:10.992Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:37:11.007Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-08T03:37:22.992Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:37:23.003Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-08T03:37:34.992Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:37:35.003Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T03:37:46.988Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-08T03:37:47.003Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.9)
2025-11-08T03:37:58.988Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:38:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:38:10.988Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:38:22.984Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:38:34.984Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-08T03:38:46.984Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.1 due to current limit: Active-LoadBalancing
2025-11-08T03:38:46.996Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.1)
2025-11-08T03:38:58.980Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:38:58.996Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T03:39:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:39:10.980Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:39:10.992Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:39:22.980Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:39:22.992Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T03:39:34.980Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:39:36.671Z:USER:taskMaster.c:6582:Temperature: 30.0 C
2025-11-08T03:39:46.976Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:39:58.976Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:39:58.988Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T03:40:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:40:10.976Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:40:10.988Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:40:22.972Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:40:22.988Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T03:40:34.972Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:40:46.972Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:40:58.968Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-08T03:41:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:41:10.968Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.1 due to current limit: Active-LoadBalancing
2025-11-08T03:41:10.980Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-08T03:41:22.968Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:41:22.980Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T03:41:34.964Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:41:34.980Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:41:46.964Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:41:46.976Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T03:41:58.964Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:41:58.976Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T03:42:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:42:10.960Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T03:42:10.976Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.7)
2025-11-08T03:42:22.960Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-08T03:42:22.972Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.7->23.5)
2025-11-08T03:42:34.960Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:42:46.957Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:42:58.957Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:43:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:43:10.957Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:43:10.968Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-08T03:43:22.953Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:43:22.968Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T03:43:34.953Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-08T03:43:34.964Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-08T03:43:46.953Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-08T03:43:46.964Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-08T03:43:58.949Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:44:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:44:10.949Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:44:22.949Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:44:22.960Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T03:44:32.941Z:INFO:active_lb.c:308:SMt:(14.0 16.0 15.0)A Free:(2.0 0.0 1.0)A ALB:(16.0 14.5 15.1)A
2025-11-08T03:44:34.945Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-08T03:44:34.960Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-08T03:44:46.945Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.2 due to current limit: Active-LoadBalancing
2025-11-08T03:44:46.957Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-08T03:44:58.945Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:45:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T03:45:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:45:10.941Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:45:22.941Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:45:22.953Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T03:45:34.941Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-08T03:45:34.953Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-08T03:45:46.937Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:45:58.937Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:46:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:46:10.937Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:46:10.949Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T03:46:22.933Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:46:22.949Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T03:46:34.933Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T03:46:34.945Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-08T03:46:46.933Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-08T03:46:46.945Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-08T03:46:58.929Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:47:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:47:10.929Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:47:22.929Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:47:34.929Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T03:47:46.925Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:47:46.937Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T03:47:58.925Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:47:58.937Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:48:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:48:10.925Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:48:10.937Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T03:48:22.921Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:48:22.933Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T03:48:34.921Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T03:48:34.933Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.7)
2025-11-08T03:48:46.921Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:48:58.917Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:49:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:49:10.312Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=234.9V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T03:49:10.324Z:USER:taskMaster.c:6720:Socket #1: I1=14.3A I2=14.4A I3=14.3A P=10.1kW Idc=0.7mA
2025-11-08T03:49:10.917Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:49:22.917Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:49:22.929Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-08T03:49:34.914Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:49:34.929Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-08T03:49:46.914Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:49:46.925Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T03:49:58.914Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-08T03:49:58.925Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-08T03:50:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:50:10.910Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:50:22.910Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:50:34.910Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:50:46.906Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:50:46.921Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T03:50:58.906Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:50:58.917Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:51:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:51:10.906Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:51:10.917Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T03:51:22.902Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:51:22.917Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T03:51:34.902Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T03:51:34.914Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-08T03:51:46.902Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-08T03:51:46.914Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-08T03:51:58.898Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:52:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:52:10.898Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:52:22.898Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:52:34.894Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T03:52:46.894Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:52:46.906Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T03:52:58.894Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:52:58.906Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:53:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:53:10.890Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:53:10.906Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T03:53:22.890Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:53:22.902Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T03:53:34.890Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T03:53:34.902Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-08T03:53:46.886Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-08T03:53:46.902Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-08T03:53:58.886Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:54:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:54:10.886Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:54:22.882Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:54:32.878Z:INFO:active_lb.c:308:SMt:(14.0 15.0 15.0)A Free:(2.0 1.0 1.0)A ALB:(15.9 14.8 15.0)A
2025-11-08T03:54:34.882Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T03:54:37.027Z:USER:taskMaster.c:6582:Temperature: 30.4 C
2025-11-08T03:54:46.882Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:54:46.894Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.8)
2025-11-08T03:54:58.878Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:54:58.894Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:55:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:55:10.878Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:55:10.890Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T03:55:22.878Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:55:22.890Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T03:55:34.878Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.3 due to current limit: Active-LoadBalancing
2025-11-08T03:55:34.890Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.8)
2025-11-08T03:55:46.875Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:55:58.875Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:56:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:56:10.875Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.0 due to current limit: Active-LoadBalancing
2025-11-08T03:56:22.871Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T03:56:22.882Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.6)
2025-11-08T03:56:34.871Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:56:34.882Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.3)
2025-11-08T03:56:46.871Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:56:58.867Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-08T03:57:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:57:10.867Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T03:57:10.878Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.0->24.8)
2025-11-08T03:57:22.867Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:57:22.878Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.8->24.5)
2025-11-08T03:57:34.863Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.6 due to current limit: Active-LoadBalancing
2025-11-08T03:57:34.878Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.5->24.3)
2025-11-08T03:57:46.863Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T03:57:46.875Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T03:57:58.863Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.2 due to current limit: Active-LoadBalancing
2025-11-08T03:57:58.875Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.0->23.7)
2025-11-08T03:58:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:58:10.859Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:58:22.859Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T03:58:34.859Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.5 due to current limit: Active-LoadBalancing
2025-11-08T03:58:34.871Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.1)
2025-11-08T03:58:46.855Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.3 due to current limit: Active-LoadBalancing
2025-11-08T03:58:46.871Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->23.8)
2025-11-08T03:58:58.855Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.1 due to current limit: Active-LoadBalancing
2025-11-08T03:58:58.867Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.8->23.5)
2025-11-08T03:59:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T03:59:10.855Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->13.9 due to current limit: Active-LoadBalancing
2025-11-08T03:59:10.867Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.5->23.2)
2025-11-08T03:59:22.851Z:INFO:taskMain.c:5996:Socket #1: Active current 13.9->13.8 due to current limit: Active-LoadBalancing
2025-11-08T03:59:22.867Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.2->22.9)
2025-11-08T03:59:34.851Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.6 due to current limit: Active-LoadBalancing
2025-11-08T03:59:34.863Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.9->22.6)
2025-11-08T03:59:46.851Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-08T03:59:46.863Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.6->22.3)
2025-11-08T03:59:58.847Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->13.6 due to current limit: Active-LoadBalancing
2025-11-08T04:00:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T04:00:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:00:10.847Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->13.4 due to current limit: Active-LoadBalancing
2025-11-08T04:00:10.859Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.7->22.3)
2025-11-08T04:00:22.847Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->12.4 due to current limit: Active-LoadBalancing
2025-11-08T04:00:22.859Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.3->20.7)
2025-11-08T04:00:23.496Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.7% (12.4 A)
2025-11-08T04:00:34.843Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:00:34.859Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.7->19.1)
2025-11-08T04:00:35.613Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.1% (11.5 A)
2025-11-08T04:00:37.742Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-08T04:00:37.750Z:INFO:db_chargingprofi:26: socket 0
2025-11-08T04:00:37.757Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-08T04:00:37.769Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-08T04:00:37.777Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-08T04:00:37.785Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-08T04:00:37.796Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-08T04:00:37.804Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-08T04:00:37.812Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-08T04:00:37.820Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-08T04:00:37.828Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-08T04:00:37.835Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-08T04:00:37.843Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-08T04:00:37.851Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-08T04:00:37.859Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-08T04:00:37.871Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-08T04:00:37.878Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-08T04:00:37.886Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-08T04:00:37.898Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-08T04:00:37.906Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-08T04:00:37.914Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-08T04:00:37.921Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-08T04:00:37.929Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-08T04:00:46.843Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->10.5 due to current limit: Active-LoadBalancing
2025-11-08T04:00:46.855Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->17.5)
2025-11-08T04:00:47.734Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.5% (10.5 A)
2025-11-08T04:00:58.843Z:INFO:taskMain.c:5996:Socket #1: Active current 10.5->10.4 due to current limit: Active-LoadBalancing
2025-11-08T04:00:58.855Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (17.5->17.3)
2025-11-08T04:01:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:01:10.839Z:INFO:taskMain.c:5996:Socket #1: Active current 10.4->10.6 due to current limit: Active-LoadBalancing
2025-11-08T04:01:22.839Z:INFO:taskMain.c:5996:Socket #1: Active current 10.6->10.9 due to current limit: Active-LoadBalancing
2025-11-08T04:01:34.839Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.1 due to current limit: Active-LoadBalancing
2025-11-08T04:01:46.835Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:01:58.835Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:02:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:02:10.835Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.8 due to current limit: Active-LoadBalancing
2025-11-08T04:02:22.832Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:02:22.847Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-08T04:02:34.832Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:02:34.843Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-08T04:02:46.832Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:02:46.843Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.8)
2025-11-08T04:02:58.828Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-08T04:02:58.843Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-08T04:03:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:03:10.828Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->10.9 due to current limit: Active-LoadBalancing
2025-11-08T04:03:10.839Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->18.2)
2025-11-08T04:03:22.828Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:03:34.824Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:03:46.824Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:03:58.824Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-08T04:04:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:04:10.214Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=235.1V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T04:04:10.230Z:USER:taskMaster.c:6720:Socket #1: I1=11.4A I2=11.4A I3=11.4A P=8.0kW Idc=0.7mA
2025-11-08T04:04:10.824Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:04:10.835Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.7->19.4)
2025-11-08T04:04:22.820Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:04:22.832Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-08T04:04:32.812Z:INFO:active_lb.c:308:SMt:(12.0 13.0 16.0)A Free:(4.0 3.0 0.0)A ALB:(15.8 14.8 11.5)A
2025-11-08T04:04:34.562Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-08T04:04:34.574Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-08T04:04:34.582Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-08T04:04:34.589Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-08T04:04:34.820Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:04:34.960Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-08T04:04:35.597Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.2/-11.4, tag: 04BB29EAFD0F94
2025-11-08T04:04:46.820Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->6.8 due to current limit: Active-LoadBalancing
2025-11-08T04:04:47.718Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.2% (6.7 A)
2025-11-08T04:04:52.160Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-08T04:04:52.171Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-08T04:04:52.179Z:USER:taskMaster.c:6684:Socket #1: L1N=236.0V L2N=236.5V L3N=236.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T04:04:52.191Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-08T04:04:52.203Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-08T04:04:52.210Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-08T04:04:52.218Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-08T04:04:52.769Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-08T04:04:53.187Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-08T04:04:58.816Z:INFO:taskMain.c:5996:Socket #1: Active current 6.8->11.0 due to current limit: Active-LoadBalancing
2025-11-08T04:04:59.246Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.3% (11.0 A)
2025-11-08T04:05:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:05:10.816Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->15.2 due to current limit: Active-LoadBalancing
2025-11-08T04:05:11.367Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.3% (15.2 A)
2025-11-08T04:05:22.207Z:USER:taskMaster.c:6684:Socket #1: L1N=234.3V L2N=234.8V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T04:05:22.222Z:USER:taskMaster.c:6720:Socket #1: I1=14.8A I2=14.8A I3=14.7A P=10.4kW Idc=0.7mA
2025-11-08T04:05:22.816Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.4 due to current limit: Active-LoadBalancing
2025-11-08T04:05:34.812Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.6 due to current limit: Active-LoadBalancing
2025-11-08T04:05:46.812Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->14.3 due to current limit: Active-LoadBalancing
2025-11-08T04:05:46.824Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.0->23.7)
2025-11-08T04:05:47.722Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.7% (14.2 A)
2025-11-08T04:05:52.171Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-08T04:05:52.207Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=235.0V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T04:05:52.218Z:USER:taskMaster.c:6720:Socket #1: I1=13.9A I2=13.9A I3=13.8A P=9.8kW Idc=0.7mA
2025-11-08T04:05:58.812Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->12.5 due to current limit: Active-LoadBalancing
2025-11-08T04:05:58.824Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.7->20.8)
2025-11-08T04:05:58.835Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.8% (12.5 A)
2025-11-08T04:06:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:06:10.808Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:06:10.824Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.8->19.2)
2025-11-08T04:06:10.949Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.2% (11.5 A)
2025-11-08T04:06:22.203Z:USER:taskMaster.c:6684:Socket #1: L1N=234.9V L2N=235.2V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T04:06:22.214Z:USER:taskMaster.c:6720:Socket #1: I1=11.2A I2=11.2A I3=11.2A P=7.9kW Idc=0.7mA
2025-11-08T04:06:22.808Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.0 due to current limit: Active-LoadBalancing
2025-11-08T04:06:22.820Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.3)
2025-11-08T04:06:23.066Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.3% (11.0 A)
2025-11-08T04:06:34.808Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->10.4 due to current limit: Active-LoadBalancing
2025-11-08T04:06:34.820Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.3->17.3)
2025-11-08T04:06:35.187Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.3% (10.4 A)
2025-11-08T04:06:46.804Z:INFO:taskMain.c:5996:Socket #1: Active current 10.4->10.3 due to current limit: Active-LoadBalancing
2025-11-08T04:06:46.820Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (17.3->17.0)
2025-11-08T04:06:52.199Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=235.5V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T04:06:52.210Z:USER:taskMaster.c:6720:Socket #1: I1=9.9A I2=9.9A I3=9.8A P=6.9kW Idc=0.7mA
2025-11-08T04:06:58.804Z:INFO:taskMain.c:5996:Socket #1: Active current 10.3->10.5 due to current limit: Active-LoadBalancing
2025-11-08T04:07:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:07:10.804Z:INFO:taskMain.c:5996:Socket #1: Active current 10.5->11.1 due to current limit: Active-LoadBalancing
2025-11-08T04:07:11.542Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.4% (11.0 A)
2025-11-08T04:07:22.195Z:USER:taskMaster.c:6684:Socket #1: L1N=234.9V L2N=235.3V L3N=235.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T04:07:22.207Z:USER:taskMaster.c:6720:Socket #1: I1=10.7A I2=10.7A I3=10.7A P=7.5kW Idc=0.7mA
2025-11-08T04:07:22.800Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:07:34.800Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:07:46.800Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-08T04:07:52.191Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=235.4V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T04:07:52.207Z:USER:taskMaster.c:6720:Socket #1: I1=11.4A I2=11.4A I3=11.4A P=8.0kW Idc=0.7mA
2025-11-08T04:07:58.796Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:07:58.812Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.4)
2025-11-08T04:08:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:08:10.796Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:08:10.808Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-08T04:08:22.191Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=235.3V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T04:08:22.203Z:USER:taskMaster.c:6720:Socket #1: I1=11.1A I2=11.1A I3=11.1A P=7.8kW Idc=0.7mA
2025-11-08T04:08:22.796Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:08:22.808Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-08T04:08:34.792Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-08T04:08:34.808Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-08T04:08:46.792Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.0 due to current limit: Active-LoadBalancing
2025-11-08T04:08:46.804Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->18.2)
2025-11-08T04:08:52.187Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=235.4V L3N=235.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T04:08:52.199Z:USER:taskMaster.c:6720:Socket #1: I1=10.6A I2=10.6A I3=10.5A P=7.4kW Idc=0.7mA
2025-11-08T04:08:58.792Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:09:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:09:10.789Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:09:22.183Z:USER:taskMaster.c:6684:Socket #1: L1N=234.9V L2N=235.5V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T04:09:22.195Z:USER:taskMaster.c:6720:Socket #1: I1=11.1A I2=11.1A I3=11.1A P=7.8kW Idc=0.7mA
2025-11-08T04:09:22.789Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:09:34.789Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.9 due to current limit: Active-LoadBalancing
2025-11-08T04:09:37.382Z:USER:taskMaster.c:6582:Temperature: 30.2 C
2025-11-08T04:09:46.785Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:09:46.800Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.8->19.4)
2025-11-08T04:09:52.179Z:USER:taskMaster.c:6684:Socket #1: L1N=234.9V L2N=235.4V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T04:09:52.191Z:USER:taskMaster.c:6720:Socket #1: I1=11.2A I2=11.3A I3=11.2A P=7.9kW Idc=0.7mA
2025-11-08T04:09:52.203Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-08T04:09:58.785Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:09:58.796Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-08T04:10:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:10:10.785Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:10:10.796Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-08T04:10:22.781Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:10:22.796Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-08T04:10:34.781Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-08T04:10:34.792Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->18.3)
2025-11-08T04:10:46.781Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:10:58.777Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:11:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:11:10.777Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:11:22.777Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:11:22.789Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-08T04:11:34.773Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:11:34.789Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-08T04:11:46.773Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:11:46.785Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-08T04:11:58.773Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-08T04:11:58.785Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->18.3)
2025-11-08T04:12:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:12:10.773Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:12:22.769Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:12:34.769Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:12:46.769Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.9 due to current limit: Active-LoadBalancing
2025-11-08T04:12:58.765Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:12:58.777Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.8->19.5)
2025-11-08T04:13:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:13:10.765Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:13:10.777Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-08T04:13:22.765Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:13:22.777Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-08T04:13:34.761Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:13:34.773Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-08T04:13:46.761Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-08T04:13:46.773Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-08T04:13:58.761Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->10.8 due to current limit: Active-LoadBalancing
2025-11-08T04:13:58.773Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.3->18.0)
2025-11-08T04:14:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:14:10.757Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->11.0 due to current limit: Active-LoadBalancing
2025-11-08T04:14:22.757Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:14:32.750Z:INFO:active_lb.c:308:SMt:(11.0 12.0 15.0)A Free:(5.0 4.0 1.0)A ALB:(15.6 14.6 11.3)A
2025-11-08T04:14:34.757Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:14:46.753Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:14:58.753Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:14:58.765Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.3)
2025-11-08T04:15:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T04:15:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:15:10.753Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:15:10.765Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.9)
2025-11-08T04:15:22.750Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:15:22.765Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-08T04:15:34.750Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-08T04:15:34.761Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-08T04:15:46.750Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->10.8 due to current limit: Active-LoadBalancing
2025-11-08T04:15:46.761Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.3->18.0)
2025-11-08T04:15:58.746Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->11.0 due to current limit: Active-LoadBalancing
2025-11-08T04:16:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:16:10.746Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:16:22.746Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:16:34.742Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:16:46.742Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:16:46.753Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.3)
2025-11-08T04:16:58.742Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:16:58.753Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.9)
2025-11-08T04:17:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:17:10.738Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:17:10.753Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-08T04:17:22.738Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-08T04:17:22.750Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-08T04:17:34.738Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->10.8 due to current limit: Active-LoadBalancing
2025-11-08T04:17:34.750Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.3->18.0)
2025-11-08T04:17:46.734Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->11.0 due to current limit: Active-LoadBalancing
2025-11-08T04:17:58.734Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:18:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:18:10.734Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:18:22.730Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:18:22.746Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-08T04:18:34.730Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:18:34.742Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-08T04:18:46.730Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-08T04:18:46.742Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-08T04:18:58.726Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->10.8 due to current limit: Active-LoadBalancing
2025-11-08T04:18:58.742Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.3->18.0)
2025-11-08T04:19:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:19:10.726Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->11.0 due to current limit: Active-LoadBalancing
2025-11-08T04:19:22.726Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:19:34.722Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:19:46.722Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:19:58.722Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:19:58.734Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-08T04:20:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:20:10.722Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:20:10.734Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-08T04:20:22.718Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:20:22.730Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-08T04:20:34.718Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-08T04:20:34.730Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-08T04:20:46.718Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->10.8 due to current limit: Active-LoadBalancing
2025-11-08T04:20:46.730Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.3->18.0)
2025-11-08T04:20:58.714Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->11.1 due to current limit: Active-LoadBalancing
2025-11-08T04:21:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:21:10.714Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:21:22.714Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:21:34.710Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:21:34.726Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-08T04:21:46.710Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:21:46.722Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-08T04:21:58.710Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-08T04:21:58.722Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->18.3)
2025-11-08T04:22:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:22:10.707Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:22:22.707Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:22:34.707Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:22:34.718Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-08T04:22:46.703Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:22:58.703Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:22:58.714Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-08T04:23:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:23:10.703Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:23:10.714Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-08T04:23:22.699Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:23:34.699Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:23:46.699Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:23:46.710Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.2)
2025-11-08T04:23:58.695Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:23:58.710Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-08T04:24:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:24:10.695Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:24:10.707Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-08T04:24:22.695Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-08T04:24:22.707Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-08T04:24:32.687Z:INFO:active_lb.c:308:SMt:(12.0 12.0 15.0)A Free:(4.0 4.0 1.0)A ALB:(14.9 15.0 11.0)A
2025-11-08T04:24:34.691Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:24:37.785Z:USER:taskMaster.c:6582:Temperature: 29.9 C
2025-11-08T04:24:46.691Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:24:52.085Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=235.5V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T04:24:52.097Z:USER:taskMaster.c:6720:Socket #1: I1=11.1A I2=11.1A I3=11.1A P=7.8kW Idc=0.7mA
2025-11-08T04:24:58.691Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:24:58.703Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-08T04:25:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:25:10.687Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:25:22.687Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-08T04:25:34.687Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:25:34.699Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-08T04:25:46.683Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:25:46.699Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->18.9)
2025-11-08T04:25:58.683Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:25:58.695Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-08T04:26:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:26:05.027Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000027, address 0x00027000 (1)
2025-11-08T04:26:05.039Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-08T04:26:10.683Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:26:22.679Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:26:34.679Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:26:34.691Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.2)
2025-11-08T04:26:46.679Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:26:46.691Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-08T04:26:58.675Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:26:58.691Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-08T04:27:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:27:10.675Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:27:22.675Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:27:34.675Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:27:34.687Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-08T04:27:46.671Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:27:46.683Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.9)
2025-11-08T04:27:58.671Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:27:58.683Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-08T04:28:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:28:10.671Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:28:22.667Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:28:34.667Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:28:34.679Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.2)
2025-11-08T04:28:46.667Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:28:46.679Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-08T04:28:58.664Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:28:58.675Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-08T04:29:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:29:10.664Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:29:22.664Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:29:34.660Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:29:34.675Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-08T04:29:46.660Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:29:46.671Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-08T04:29:58.660Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:29:58.671Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-08T04:30:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T04:30:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:30:10.656Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-08T04:30:10.671Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.3)
2025-11-08T04:30:22.656Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:30:34.656Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:30:46.652Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:30:58.652Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:30:58.664Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-08T04:31:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:31:10.652Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:31:10.664Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-08T04:31:22.648Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:31:22.664Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-08T04:31:34.648Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:31:46.648Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:31:58.644Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:31:58.660Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.2)
2025-11-08T04:32:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:32:10.644Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:32:10.656Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-08T04:32:22.644Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:32:22.656Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-08T04:32:34.640Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:32:46.640Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:32:58.640Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:32:58.652Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-08T04:33:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:33:10.636Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:33:10.652Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-08T04:33:22.636Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:33:22.648Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.7)
2025-11-08T04:33:34.636Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:33:46.632Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:33:58.632Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:33:58.644Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-08T04:34:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:34:10.632Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:34:10.644Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-08T04:34:22.628Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:34:22.644Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-08T04:34:32.625Z:INFO:active_lb.c:308:SMt:(11.0 12.0 16.0)A Free:(5.0 4.0 0.0)A ALB:(15.9 14.3 11.2)A
2025-11-08T04:34:34.628Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-08T04:34:34.640Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.4)
2025-11-08T04:34:46.628Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:34:58.628Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:35:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:35:10.625Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:35:22.625Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:35:22.636Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.2)
2025-11-08T04:35:34.625Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:35:34.636Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-08T04:35:46.621Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:35:46.632Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.6)
2025-11-08T04:35:58.621Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.0 due to current limit: Active-LoadBalancing
2025-11-08T04:35:58.632Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.6->18.4)
2025-11-08T04:36:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:36:10.621Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:36:22.617Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:36:34.617Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:36:46.617Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:36:46.628Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-08T04:36:58.613Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:36:58.628Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-08T04:37:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:37:10.613Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-08T04:37:10.625Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-08T04:37:22.613Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:37:34.609Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:37:46.609Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:37:46.621Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-08T04:37:58.609Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:37:58.621Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-08T04:38:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:38:10.605Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-08T04:38:10.621Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-08T04:38:22.605Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:38:34.605Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:38:46.601Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:38:58.601Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:38:58.613Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-08T04:39:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:39:10.601Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:39:10.613Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-08T04:39:22.597Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-08T04:39:22.613Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.4)
2025-11-08T04:39:34.597Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:39:38.140Z:USER:taskMaster.c:6582:Temperature: 29.6 C
2025-11-08T04:39:46.597Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:39:51.988Z:USER:taskMaster.c:6684:Socket #1: L1N=234.4V L2N=235.1V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T04:39:52.003Z:USER:taskMaster.c:6720:Socket #1: I1=11.0A I2=11.1A I3=11.0A P=7.8kW Idc=0.7mA
2025-11-08T04:39:58.593Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:40:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:40:10.593Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:40:10.605Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-08T04:40:22.593Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:40:22.605Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-08T04:40:34.589Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-08T04:40:34.605Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.4)
2025-11-08T04:40:46.589Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:40:58.589Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:41:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:41:10.585Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:41:22.585Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:41:22.597Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-08T04:41:34.585Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:41:34.597Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-08T04:41:46.582Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-08T04:41:46.597Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.4)
2025-11-08T04:41:58.582Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:42:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:42:10.582Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:42:22.582Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:42:34.578Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:42:34.589Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-08T04:42:46.578Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:42:46.589Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-08T04:42:58.578Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:42:58.589Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.7)
2025-11-08T04:43:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:43:10.574Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.1 due to current limit: Active-LoadBalancing
2025-11-08T04:43:10.585Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-08T04:43:22.574Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->10.9 due to current limit: Active-LoadBalancing
2025-11-08T04:43:22.585Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.4->18.1)
2025-11-08T04:43:34.574Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->10.7 due to current limit: Active-LoadBalancing
2025-11-08T04:43:34.585Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.1->17.8)
2025-11-08T04:43:46.570Z:INFO:taskMain.c:5996:Socket #1: Active current 10.7->10.9 due to current limit: Active-LoadBalancing
2025-11-08T04:43:58.570Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:44:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:44:10.570Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:44:22.566Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:44:32.558Z:INFO:active_lb.c:308:SMt:(11.0 12.0 16.0)A Free:(5.0 4.0 0.0)A ALB:(15.7 14.8 11.6)A
2025-11-08T04:44:34.566Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:44:34.578Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-08T04:44:46.566Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:44:46.578Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-08T04:44:58.562Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-08T04:44:58.578Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-08T04:45:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T04:45:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:45:10.562Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:45:22.562Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:45:34.558Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.8 due to current limit: Active-LoadBalancing
2025-11-08T04:45:46.558Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:45:46.570Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-08T04:45:58.558Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:45:58.570Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-08T04:46:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:46:10.554Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:46:10.570Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-08T04:46:22.554Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-08T04:46:22.566Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-08T04:46:34.554Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:46:46.550Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:46:58.550Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:47:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:47:10.550Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:47:10.562Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-08T04:47:22.546Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:47:22.562Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->19.0)
2025-11-08T04:47:34.546Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:47:34.558Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-08T04:47:46.546Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-08T04:47:46.558Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-08T04:47:58.542Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:48:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:48:10.542Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:48:22.542Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.8 due to current limit: Active-LoadBalancing
2025-11-08T04:48:34.539Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:48:34.554Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-08T04:48:46.539Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:48:46.550Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-08T04:48:58.539Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:48:58.550Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-08T04:49:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:49:10.535Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-08T04:49:10.550Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.5)
2025-11-08T04:49:22.535Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:49:34.535Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:49:46.535Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.8 due to current limit: Active-LoadBalancing
2025-11-08T04:49:58.531Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:49:58.542Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-08T04:50:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:50:10.531Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:50:10.542Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-08T04:50:22.531Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:50:22.542Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.8)
2025-11-08T04:50:34.527Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-08T04:50:34.539Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-08T04:50:46.527Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:50:58.527Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:51:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:51:10.523Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:51:10.539Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-08T04:51:22.523Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:51:22.535Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.8)
2025-11-08T04:51:34.523Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-08T04:51:34.535Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-08T04:51:46.519Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:51:58.519Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:52:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:52:10.519Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-08T04:52:22.515Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:52:22.531Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.7->19.4)
2025-11-08T04:52:34.515Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:52:34.527Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-08T04:52:46.515Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:52:46.527Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-08T04:52:58.511Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-08T04:52:58.527Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-08T04:53:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:53:10.511Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:53:22.511Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:53:34.507Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-08T04:53:46.507Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:53:46.519Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.4)
2025-11-08T04:53:58.507Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:53:58.519Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-08T04:54:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:54:10.503Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:54:10.519Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-08T04:54:22.503Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-08T04:54:22.515Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-08T04:54:32.496Z:INFO:active_lb.c:308:SMt:(12.0 12.0 16.0)A Free:(4.0 4.0 0.0)A ALB:(14.7 14.9 11.1)A
2025-11-08T04:54:34.503Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:54:38.546Z:USER:taskMaster.c:6582:Temperature: 29.5 C
2025-11-08T04:54:46.500Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:54:51.894Z:USER:taskMaster.c:6684:Socket #1: L1N=234.2V L2N=235.0V L3N=234.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T04:54:51.906Z:USER:taskMaster.c:6720:Socket #1: I1=11.1A I2=11.2A I3=11.1A P=7.8kW Idc=0.7mA
2025-11-08T04:54:58.500Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-08T04:55:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:55:10.500Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.7 due to current limit: Active-LoadBalancing
2025-11-08T04:55:10.511Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.7->19.4)
2025-11-08T04:55:22.496Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:55:22.511Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-08T04:55:34.496Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:55:34.507Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-08T04:55:46.496Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:55:46.507Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-08T04:55:58.492Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:56:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:56:10.492Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:56:22.492Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-08T04:56:34.488Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:56:34.503Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.4)
2025-11-08T04:56:46.488Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:56:46.500Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-08T04:56:58.488Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:56:58.500Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-08T04:57:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:57:10.488Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:57:10.500Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-08T04:57:22.484Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:57:34.484Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:57:46.484Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-08T04:57:58.480Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:57:58.492Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.4)
2025-11-08T04:58:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:58:10.480Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-08T04:58:10.492Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-08T04:58:22.480Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:58:22.492Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-08T04:58:34.476Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-08T04:58:34.492Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.6)
2025-11-08T04:58:46.476Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:58:58.476Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:59:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T04:59:10.472Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-08T04:59:22.472Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-08T04:59:22.484Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-08T04:59:34.472Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T04:59:34.484Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-08T04:59:46.468Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-08T04:59:46.484Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.8)
2025-11-08T04:59:58.468Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-08T04:59:58.480Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-08T05:00:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T05:00:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:00:10.468Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-08T05:00:22.464Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-08T05:00:34.464Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-08T05:00:45.312Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-08T05:00:45.320Z:INFO:db_chargingprofi:26: socket 0
2025-11-08T05:00:45.332Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-08T05:00:45.339Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-08T05:00:45.347Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-08T05:00:45.359Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-08T05:00:45.367Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-08T05:00:45.378Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-08T05:00:45.386Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-08T05:00:45.394Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-08T05:00:45.402Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-08T05:00:45.410Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-08T05:00:45.417Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-08T05:00:45.425Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-08T05:00:45.433Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-08T05:00:45.445Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-08T05:00:45.453Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-08T05:00:45.460Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-08T05:00:45.468Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-08T05:00:45.480Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-08T05:00:45.484Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-08T05:00:45.496Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-08T05:00:45.503Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-08T05:00:46.464Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-08T05:00:46.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-08T05:00:58.460Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T05:00:58.476Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-08T05:01:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:01:10.460Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-08T05:01:10.472Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.8)
2025-11-08T05:01:22.460Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-08T05:01:22.472Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-08T05:01:34.457Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.0 due to current limit: Active-LoadBalancing
2025-11-08T05:01:34.472Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.5->18.2)
2025-11-08T05:01:46.457Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.2 due to current limit: Active-LoadBalancing
2025-11-08T05:01:58.457Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.4 due to current limit: Active-LoadBalancing
2025-11-08T05:02:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:02:10.453Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-08T05:02:22.453Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.5 due to current limit: Active-LoadBalancing
2025-11-08T05:02:22.464Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.4->19.1)
2025-11-08T05:02:34.453Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T05:02:34.464Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-08T05:02:46.449Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-08T05:02:46.464Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.4)
2025-11-08T05:02:58.449Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-08T05:03:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:03:10.449Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T05:03:22.445Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-08T05:03:34.445Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.9 due to current limit: Active-LoadBalancing
2025-11-08T05:03:46.445Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.7 due to current limit: Active-LoadBalancing
2025-11-08T05:03:46.457Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.8->19.5)
2025-11-08T05:03:58.445Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-08T05:03:58.457Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-08T05:04:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:04:10.441Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T05:04:10.453Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-08T05:04:22.441Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T05:04:22.453Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.7)
2025-11-08T05:04:32.433Z:INFO:active_lb.c:308:SMt:(11.0 12.0 16.0)A Free:(5.0 4.0 0.0)A ALB:(15.2 14.8 11.2)A
2025-11-08T05:04:34.441Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.1 due to current limit: Active-LoadBalancing
2025-11-08T05:04:34.453Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-08T05:04:46.437Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-08T05:04:58.437Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T05:05:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:05:10.437Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-08T05:05:22.433Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.9 due to current limit: Active-LoadBalancing
2025-11-08T05:05:34.433Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.7 due to current limit: Active-LoadBalancing
2025-11-08T05:05:34.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.7->19.5)
2025-11-08T05:05:46.433Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-08T05:05:46.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-08T05:05:58.429Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T05:05:58.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->18.9)
2025-11-08T05:06:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:06:10.429Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T05:06:10.441Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.9->18.7)
2025-11-08T05:06:22.429Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.5 due to current limit: Active-LoadBalancing
2025-11-08T05:06:34.425Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-08T05:06:46.425Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.9 due to current limit: Active-LoadBalancing
2025-11-08T05:06:58.425Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.7 due to current limit: Active-LoadBalancing
2025-11-08T05:06:58.437Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.7->19.5)
2025-11-08T05:07:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:07:10.421Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.6 due to current limit: Active-LoadBalancing
2025-11-08T05:07:10.437Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.5->19.2)
2025-11-08T05:07:22.421Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T05:07:22.433Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.2->19.0)
2025-11-08T05:07:34.421Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T05:07:34.433Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-08T05:07:46.417Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.1 due to current limit: Active-LoadBalancing
2025-11-08T05:07:46.433Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.4)
2025-11-08T05:07:58.417Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->10.9 due to current limit: Active-LoadBalancing
2025-11-08T05:07:58.429Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.4->18.1)
2025-11-08T05:08:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:08:10.417Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.1 due to current limit: Active-LoadBalancing
2025-11-08T05:08:22.414Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-08T05:08:34.414Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.6 due to current limit: Active-LoadBalancing
2025-11-08T05:08:46.414Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T05:08:46.425Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.0)
2025-11-08T05:08:58.410Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.3 due to current limit: Active-LoadBalancing
2025-11-08T05:08:58.425Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.0->18.7)
2025-11-08T05:09:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:09:10.410Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-08T05:09:10.421Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.7->18.5)
2025-11-08T05:09:22.410Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-08T05:09:34.406Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T05:09:38.953Z:USER:taskMaster.c:6582:Temperature: 29.1 C
2025-11-08T05:09:46.406Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.8 due to current limit: Active-LoadBalancing
2025-11-08T05:09:51.800Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.1V L3N=232.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T05:09:51.812Z:USER:taskMaster.c:6720:Socket #1: I1=11.4A I2=11.4A I3=11.4A P=8.0kW Idc=0.7mA
2025-11-08T05:09:58.406Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-08T05:09:58.417Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-08T05:10:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:10:10.402Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-08T05:10:10.417Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.1)
2025-11-08T05:10:22.402Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T05:10:22.414Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-08T05:10:34.402Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.1 due to current limit: Active-LoadBalancing
2025-11-08T05:10:34.414Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (18.8->18.5)
2025-11-08T05:10:46.398Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.3 due to current limit: Active-LoadBalancing
2025-11-08T05:10:58.398Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T05:11:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:11:10.398Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.8 due to current limit: Active-LoadBalancing
2025-11-08T05:11:22.398Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->11.6 due to current limit: Active-LoadBalancing
2025-11-08T05:11:22.410Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->19.3)
2025-11-08T05:11:34.394Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.5 due to current limit: Active-LoadBalancing
2025-11-08T05:11:34.406Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.3->19.1)
2025-11-08T05:11:46.394Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T05:11:46.406Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.1->18.8)
2025-11-08T05:11:58.394Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.5 due to current limit: Active-LoadBalancing
2025-11-08T05:12:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:12:10.390Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-08T05:12:21.433Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-08T05:12:21.445Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-08T05:12:21.453Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-08T05:12:21.460Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-08T05:12:21.832Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.3 V
2025-11-08T05:12:22.390Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->7.4 due to current limit: Active-LoadBalancing
2025-11-08T05:12:22.441Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.3% (7.4 A)
2025-11-08T05:12:22.449Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-08T05:12:34.390Z:INFO:taskMain.c:5996:Socket #1: Active current 7.4->4.9 due to current limit: Active-LoadBalancing
2025-11-08T05:12:34.402Z:WARNING:taskMain.c:4698:Socket #1: maximum current(4.86) < minimum current(6.00)
2025-11-08T05:12:34.433Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-08T05:12:34.445Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-08T05:12:34.453Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-08T05:12:34.558Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-08T05:12:35.429Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-11-08T05:12:35.429Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-08T05:12:46.386Z:INFO:taskMain.c:5996:Socket #1: Active current 4.9->7.7 due to current limit: Active-LoadBalancing
2025-11-08T05:12:46.429Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-08T05:12:46.441Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-08T05:12:46.449Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-08T05:12:46.539Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-08T05:12:47.437Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-08T05:12:58.386Z:INFO:taskMain.c:5996:Socket #1: Active current 7.7->9.4 due to current limit: Active-LoadBalancing
2025-11-08T05:12:58.546Z:INFO:taskMain.c:6510:Socket #1: PWM DC 15.7% (9.4 A)
2025-11-08T05:13:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:13:10.386Z:INFO:taskMain.c:5996:Socket #1: Active current 9.4->10.5 due to current limit: Active-LoadBalancing
2025-11-08T05:13:10.664Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.4% (10.4 A)
2025-11-08T05:13:16.476Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-08T05:13:16.488Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-08T05:13:16.722Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-08T05:13:16.730Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-08T05:13:17.472Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-08T05:13:20.476Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-08T05:13:20.503Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-08T05:13:20.511Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-08T05:13:20.976Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-08T05:13:20.988Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-08T05:13:21.515Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-08T05:13:22.003Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-08T05:13:22.382Z:INFO:taskMain.c:5996:Socket #1: Active current 10.5->11.1 due to current limit: Active-LoadBalancing
2025-11-08T05:13:23.015Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.4% (11.0 A)
2025-11-08T05:13:34.382Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.4 due to current limit: Active-LoadBalancing
2025-11-08T05:13:35.132Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.0% (11.4 A)
2025-11-08T05:13:46.382Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.7 due to current limit: Active-LoadBalancing
2025-11-08T05:13:58.378Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.8 due to current limit: Active-LoadBalancing
2025-11-08T05:14:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:14:22.378Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.9 due to current limit: Active-LoadBalancing
2025-11-08T05:14:32.371Z:INFO:active_lb.c:308:SMt:(1.0 1.0 4.0)A Free:(15.0 15.0 12.0)A ALB:(14.9 14.9 11.9)A
2025-11-08T05:15:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T05:15:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:16:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:17:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:18:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:19:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:20:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:21:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:22:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:23:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:24:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:24:32.308Z:INFO:active_lb.c:308:SMt:(1.0 2.0 4.0)A Free:(15.0 14.0 12.0)A ALB:(15.0 14.0 12.0)A
2025-11-08T05:24:39.355Z:USER:taskMaster.c:6582:Temperature: 27.1 C
2025-11-08T05:24:51.707Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.3V L3N=233.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T05:24:51.718Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-08T05:25:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:26:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:27:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:27:04.441Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000028, address 0x00028000 (1)
2025-11-08T05:27:04.453Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-08T05:28:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:29:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:30:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T05:30:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:31:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:32:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:33:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:34:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:34:18.160Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-08T05:34:18.429Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-08T05:34:23.843Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-08T05:34:23.855Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-08T05:34:32.242Z:INFO:active_lb.c:308:SMt:(3.0 1.0 4.0)A Free:(13.0 15.0 12.0)A ALB:(14.6 14.9 12.0)A
2025-11-08T05:35:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:36:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:37:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:38:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:39:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:39:39.710Z:USER:taskMaster.c:6582:Temperature: 25.4 C
2025-11-08T05:39:51.609Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=233.4V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T05:39:51.621Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-08T05:40:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:41:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:42:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:43:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:44:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:44:32.179Z:INFO:active_lb.c:308:SMt:(1.0 1.0 4.0)A Free:(15.0 15.0 12.0)A ALB:(15.0 15.0 12.0)A
2025-11-08T05:45:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T05:45:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:46:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:47:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:48:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:49:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:50:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:51:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:52:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:53:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:54:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:54:32.117Z:INFO:active_lb.c:308:SMt:(1.0 1.0 4.0)A Free:(15.0 15.0 12.0)A ALB:(14.8 15.0 12.0)A
2025-11-08T05:54:40.066Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-08T05:54:51.515Z:USER:taskMaster.c:6684:Socket #1: L1N=232.2V L2N=232.5V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T05:54:51.527Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-08T05:55:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:56:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:57:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:58:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T05:59:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:00:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T06:00:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:00:52.882Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-08T06:00:52.890Z:INFO:db_chargingprofi:26: socket 0
2025-11-08T06:00:52.898Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-08T06:00:52.906Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-08T06:00:52.914Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-08T06:00:52.921Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-08T06:00:52.933Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-08T06:00:52.945Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-08T06:00:52.957Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-08T06:00:52.964Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-08T06:00:52.972Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-08T06:00:52.980Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-08T06:00:52.988Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-08T06:00:52.996Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-08T06:00:53.003Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-08T06:00:53.011Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-08T06:00:53.019Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-08T06:00:53.031Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-08T06:00:53.039Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-08T06:00:53.046Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-08T06:00:53.054Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-08T06:00:53.062Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-08T06:00:53.070Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-08T06:01:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:02:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:03:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:04:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:04:32.054Z:INFO:active_lb.c:308:SMt:(1.0 1.0 4.0)A Free:(15.0 15.0 12.0)A ALB:(15.0 15.0 12.0)A
2025-11-08T06:05:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:05:10.054Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->11.6 due to current limit: Active-LoadBalancing
2025-11-08T06:05:10.457Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.3% (11.6 A)
2025-11-08T06:05:22.054Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-08T06:05:46.050Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.9 due to current limit: Active-LoadBalancing
2025-11-08T06:06:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:07:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:08:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:09:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:09:40.421Z:USER:taskMaster.c:6582:Temperature: 23.5 C
2025-11-08T06:09:51.421Z:USER:taskMaster.c:6684:Socket #1: L1N=235.1V L2N=235.7V L3N=235.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T06:09:51.433Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-08T06:10:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:11:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:12:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:13:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:14:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:14:31.992Z:INFO:active_lb.c:308:SMt:(1.0 2.0 4.0)A Free:(15.0 14.0 12.0)A ALB:(15.0 14.0 12.0)A
2025-11-08T06:15:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T06:15:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:16:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:17:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:17:32.726Z:INFO:taskLeds.c:338:Brightness set to 35%
2025-11-08T06:18:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:18:46.019Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->11.6 due to current limit: Active-LoadBalancing
2025-11-08T06:18:46.449Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.3% (11.6 A)
2025-11-08T06:18:58.019Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T06:19:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:19:10.015Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-08T06:19:22.015Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-08T06:19:46.011Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.9 due to current limit: Active-LoadBalancing
2025-11-08T06:20:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:21:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:22:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:23:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:24:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:24:31.925Z:INFO:active_lb.c:308:SMt:(1.0 1.0 4.0)A Free:(15.0 15.0 12.0)A ALB:(14.9 15.0 12.0)A
2025-11-08T06:24:40.824Z:USER:taskMaster.c:6582:Temperature: 22.9 C
2025-11-08T06:24:51.324Z:USER:taskMaster.c:6684:Socket #1: L1N=234.5V L2N=235.2V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T06:24:51.335Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-08T06:25:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:26:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:27:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:27:32.664Z:INFO:taskLeds.c:338:Brightness set to 65%
2025-11-08T06:28:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:28:04.554Z:INFO:db_base.c:658:Erasing Transaction db sector 0x00000029, address 0x00029000 (1)
2025-11-08T06:28:04.566Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-08T06:28:09.960Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->11.6 due to current limit: Active-LoadBalancing
2025-11-08T06:28:09.972Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.3% (11.6 A)
2025-11-08T06:28:21.957Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T06:28:33.957Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-08T06:28:45.957Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-08T06:29:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:29:09.953Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.5 due to current limit: Active-LoadBalancing
2025-11-08T06:29:10.554Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.1% (11.5 A)
2025-11-08T06:29:21.953Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T06:29:33.949Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.2 due to current limit: Active-LoadBalancing
2025-11-08T06:29:45.949Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->11.5 due to current limit: Active-LoadBalancing
2025-11-08T06:29:57.949Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-08T06:30:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T06:30:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:30:09.945Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.8 due to current limit: Active-LoadBalancing
2025-11-08T06:30:33.945Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.9 due to current limit: Active-LoadBalancing
2025-11-08T06:31:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:32:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:33:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:33:21.925Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->11.6 due to current limit: Active-LoadBalancing
2025-11-08T06:33:22.015Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.3% (11.6 A)
2025-11-08T06:33:33.925Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T06:33:45.925Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T06:34:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:34:09.921Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.1 due to current limit: Active-LoadBalancing
2025-11-08T06:34:31.863Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-08T06:35:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:36:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:37:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:37:32.699Z:INFO:taskLeds.c:338:Brightness set to 100%
2025-11-08T06:38:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:39:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:39:41.179Z:USER:taskMaster.c:6582:Temperature: 22.5 C
2025-11-08T06:39:51.230Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=233.0V L3N=232.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T06:39:51.242Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-08T06:40:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:41:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:42:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:43:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:44:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:44:31.800Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-08T06:45:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T06:45:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:46:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:47:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:48:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:49:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:49:45.820Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.4 due to current limit: Active-LoadBalancing
2025-11-08T06:49:46.660Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.0% (11.4 A)
2025-11-08T06:49:57.820Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.6 due to current limit: Active-LoadBalancing
2025-11-08T06:50:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:50:09.820Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-08T06:50:33.816Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.9 due to current limit: Active-LoadBalancing
2025-11-08T06:51:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:52:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:52:57.800Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->11.6 due to current limit: Active-LoadBalancing
2025-11-08T06:52:58.542Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.3% (11.6 A)
2025-11-08T06:53:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:53:09.800Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T06:53:21.800Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T06:53:45.796Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.1 due to current limit: Active-LoadBalancing
2025-11-08T06:54:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:54:31.734Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-08T06:54:41.585Z:USER:taskMaster.c:6582:Temperature: 22.5 C
2025-11-08T06:54:51.132Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=232.6V L3N=231.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T06:54:51.144Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=1.0mA
2025-11-08T06:55:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:56:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:57:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:58:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:58:57.761Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->11.4 due to current limit: Active-LoadBalancing
2025-11-08T06:58:58.062Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.0% (11.4 A)
2025-11-08T06:59:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T06:59:09.761Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T06:59:33.757Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.1 due to current limit: Active-LoadBalancing
2025-11-08T06:59:45.757Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.5 due to current limit: Active-LoadBalancing
2025-11-08T06:59:46.539Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.0% (11.4 A)
2025-11-08T06:59:57.757Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.7 due to current limit: Active-LoadBalancing
2025-11-08T07:00:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T07:00:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:00:09.753Z:INFO:taskMain.c:5996:Socket #1: Active current 11.7->11.8 due to current limit: Active-LoadBalancing
2025-11-08T07:00:33.753Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.9 due to current limit: Active-LoadBalancing
2025-11-08T07:01:00.347Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-08T07:01:00.355Z:INFO:db_chargingprofi:26: socket 0
2025-11-08T07:01:00.363Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-08T07:01:00.375Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-08T07:01:00.382Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-08T07:01:00.390Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-08T07:01:00.402Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-08T07:01:00.410Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-08T07:01:00.417Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-08T07:01:00.425Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-08T07:01:00.433Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-08T07:01:00.441Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-08T07:01:00.449Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-08T07:01:00.457Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-08T07:01:00.464Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-08T07:01:00.476Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-08T07:01:00.484Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-08T07:01:00.492Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-08T07:01:00.503Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-08T07:01:00.511Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-08T07:01:00.519Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-08T07:01:00.527Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-08T07:01:00.535Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-08T07:01:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:02:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:02:33.742Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->11.6 due to current limit: Active-LoadBalancing
2025-11-08T07:02:34.179Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.3% (11.6 A)
2025-11-08T07:02:45.738Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.4 due to current limit: Active-LoadBalancing
2025-11-08T07:02:57.738Z:INFO:taskMain.c:5996:Socket #1: Active current 11.4->11.2 due to current limit: Active-LoadBalancing
2025-11-08T07:03:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:03:21.734Z:INFO:taskMain.c:5996:Socket #1: Active current 11.1->11.1 due to current limit: Active-LoadBalancing
2025-11-08T07:04:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:04:31.671Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-08T07:05:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:06:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:07:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:08:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:09:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:09:41.890Z:USER:taskMaster.c:6582:Temperature: 22.4 C
2025-11-08T07:09:51.039Z:USER:taskMaster.c:6684:Socket #1: L1N=234.3V L2N=236.0V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T07:09:51.050Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-08T07:10:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:11:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:12:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:13:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:14:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:14:31.609Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(15.0 15.0 11.0)A
2025-11-08T07:15:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T07:15:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:16:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:17:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:18:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:19:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:20:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:21:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:22:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:23:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:24:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:24:31.542Z:INFO:active_lb.c:308:SMt:(1.0 1.0 5.0)A Free:(15.0 15.0 11.0)A ALB:(14.4 15.0 11.0)A
2025-11-08T07:24:42.292Z:USER:taskMaster.c:6582:Temperature: 22.5 C
2025-11-08T07:24:50.941Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=235.5V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T07:24:50.953Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-08T07:25:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:26:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:27:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:28:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:29:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:29:57.566Z:INFO:taskMain.c:5996:Socket #1: Active current 11.0->12.6 due to current limit: Active-LoadBalancing
2025-11-08T07:29:58.285Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-11-08T07:30:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T07:30:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:30:04.710Z:INFO:db_base.c:658:Erasing Transaction db sector 0x0000002a, address 0x0002a000 (1)
2025-11-08T07:30:04.718Z:INFO:db_transaction.:198:Resetting nextToDoItem
2025-11-08T07:30:09.566Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->13.6 due to current limit: Active-LoadBalancing
2025-11-08T07:30:10.406Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-08T07:30:21.562Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->14.1 due to current limit: Active-LoadBalancing
2025-11-08T07:30:22.523Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.5% (14.1 A)
2025-11-08T07:30:33.562Z:INFO:taskMain.c:5996:Socket #1: Active current 14.1->14.5 due to current limit: Active-LoadBalancing
2025-11-08T07:30:33.632Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-08T07:30:45.562Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T07:30:57.558Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-08T07:31:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:31:21.558Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T07:31:57.554Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->13.4 due to current limit: Active-LoadBalancing
2025-11-08T07:31:58.464Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-08T07:32:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:32:09.550Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->12.0 due to current limit: Active-LoadBalancing
2025-11-08T07:32:09.566Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.0% (12.0 A)
2025-11-08T07:32:21.550Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->11.2 due to current limit: Active-LoadBalancing
2025-11-08T07:32:21.679Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.7% (11.2 A)
2025-11-08T07:32:33.550Z:INFO:taskMain.c:5996:Socket #1: Active current 11.2->12.7 due to current limit: Active-LoadBalancing
2025-11-08T07:32:33.800Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.2% (12.7 A)
2025-11-08T07:32:45.546Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->13.6 due to current limit: Active-LoadBalancing
2025-11-08T07:32:45.917Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.7% (13.6 A)
2025-11-08T07:32:57.546Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->14.2 due to current limit: Active-LoadBalancing
2025-11-08T07:32:58.035Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.6% (14.2 A)
2025-11-08T07:33:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:33:09.546Z:INFO:taskMain.c:5996:Socket #1: Active current 14.2->14.5 due to current limit: Active-LoadBalancing
2025-11-08T07:33:21.542Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->14.7 due to current limit: Active-LoadBalancing
2025-11-08T07:33:33.542Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->14.8 due to current limit: Active-LoadBalancing
2025-11-08T07:33:57.539Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.6 due to current limit: Active-LoadBalancing
2025-11-08T07:34:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:34:09.539Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.4 due to current limit: Active-LoadBalancing
2025-11-08T07:34:21.539Z:INFO:taskMain.c:5996:Socket #1: Active current 14.4->14.6 due to current limit: Active-LoadBalancing
2025-11-08T07:34:23.082Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-08T07:34:23.089Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-08T07:34:31.480Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 14.6)A
2025-11-08T07:34:33.535Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.8 due to current limit: Active-LoadBalancing
2025-11-08T07:34:57.535Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->14.9 due to current limit: Active-LoadBalancing
2025-11-08T07:35:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:36:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:37:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:38:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:39:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:39:42.699Z:USER:taskMaster.c:6582:Temperature: 22.4 C
2025-11-08T07:39:50.847Z:USER:taskMaster.c:6684:Socket #1: L1N=233.4V L2N=235.1V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T07:39:50.859Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-08T07:39:57.503Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->12.6 due to current limit: Active-LoadBalancing
2025-11-08T07:39:58.152Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-11-08T07:40:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:40:09.500Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->10.8 due to current limit: Active-LoadBalancing
2025-11-08T07:40:10.269Z:INFO:taskMain.c:6510:Socket #1: PWM DC 17.9% (10.7 A)
2025-11-08T07:40:21.500Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->9.7 due to current limit: Active-LoadBalancing
2025-11-08T07:40:22.390Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.0% (9.6 A)
2025-11-08T07:40:33.500Z:INFO:taskMain.c:5996:Socket #1: Active current 9.7->8.6 due to current limit: Active-LoadBalancing
2025-11-08T07:40:33.511Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.3% (8.6 A)
2025-11-08T07:40:45.496Z:INFO:taskMain.c:5996:Socket #1: Active current 8.6->8.0 due to current limit: Active-LoadBalancing
2025-11-08T07:40:45.617Z:INFO:taskMain.c:6510:Socket #1: PWM DC 13.2% (7.9 A)
2025-11-08T07:40:57.496Z:INFO:taskMain.c:5996:Socket #1: Active current 8.0->6.0 due to current limit: Active-LoadBalancing
2025-11-08T07:40:57.507Z:WARNING:taskMain.c:4698:Socket #1: maximum current(5.97) < minimum current(6.00)
2025-11-08T07:40:57.539Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2025-11-08T07:40:57.550Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-08T07:40:57.558Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_FORCED_OFF
2025-11-08T07:40:57.734Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.3 V
2025-11-08T07:40:58.535Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF_LOW_MAXCURRENT, CP: 9.3/9.3, tag: 04BB
2025-11-08T07:40:58.535Z:INFO:taskMain.c:1417:29EAFD0F94
2025-11-08T07:41:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:41:09.496Z:INFO:taskMain.c:5996:Socket #1: Active current 6.0->4.8 due to current limit: Active-LoadBalancing
2025-11-08T07:41:21.492Z:INFO:taskMain.c:5996:Socket #1: Active current 4.8->4.1 due to current limit: Active-LoadBalancing
2025-11-08T07:41:33.492Z:INFO:taskMain.c:5996:Socket #1: Active current 4.1->3.6 due to current limit: Active-LoadBalancing
2025-11-08T07:41:45.492Z:INFO:taskMain.c:5996:Socket #1: Active current 3.6->3.4 due to current limit: Active-LoadBalancing
2025-11-08T07:41:57.488Z:INFO:taskMain.c:5996:Socket #1: Active current 3.4->3.2 due to current limit: Active-LoadBalancing
2025-11-08T07:42:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:42:21.488Z:INFO:taskMain.c:5996:Socket #1: Active current 3.1->4.7 due to current limit: Active-LoadBalancing
2025-11-08T07:42:33.484Z:INFO:taskMain.c:5996:Socket #1: Active current 4.7->5.6 due to current limit: Active-LoadBalancing
2025-11-08T07:42:45.484Z:INFO:taskMain.c:5996:Socket #1: Active current 5.6->6.2 due to current limit: Active-LoadBalancing
2025-11-08T07:42:45.527Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-08T07:42:45.539Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-08T07:42:45.546Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-08T07:42:45.585Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-08T07:42:45.593Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.2% (6.1 A)
2025-11-08T07:42:46.535Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-08T07:42:57.484Z:INFO:taskMain.c:5996:Socket #1: Active current 6.2->6.5 due to current limit: Active-LoadBalancing
2025-11-08T07:42:57.644Z:INFO:taskMain.c:6510:Socket #1: PWM DC 10.8% (6.5 A)
2025-11-08T07:43:04.027Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:43:09.480Z:INFO:taskMain.c:5996:Socket #1: Active current 6.5->6.7 due to current limit: Active-LoadBalancing
2025-11-08T07:43:15.574Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAKEUP
2025-11-08T07:43:15.585Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-08T07:43:15.820Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-08T07:43:15.828Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-08T07:43:16.570Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_WAKEUP, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-08T07:43:19.574Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B1
2025-11-08T07:43:19.601Z:INFO:taskMain.c:6494:Socket #1: CPhigh 9.2 V
2025-11-08T07:43:19.609Z:INFO:taskMain.c:6499:Socket #1: CPlow 9.2 V
2025-11-08T07:43:20.074Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-08T07:43:20.085Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-08T07:43:20.609Z:INFO:taskMain.c:6499:Socket #1: CPlow -11.4 V
2025-11-08T07:43:21.101Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_OFF, CP: 9.3/-11.4, tag: 04BB29EAFD0F94
2025-11-08T07:43:21.480Z:INFO:taskMain.c:5996:Socket #1: Active current 6.7->8.8 due to current limit: Active-LoadBalancing
2025-11-08T07:43:22.109Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.6% (8.8 A)
2025-11-08T07:43:33.480Z:INFO:taskMain.c:5996:Socket #1: Active current 8.8->10.1 due to current limit: Active-LoadBalancing
2025-11-08T07:43:34.230Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.8% (10.1 A)
2025-11-08T07:43:45.476Z:INFO:taskMain.c:5996:Socket #1: Active current 10.1->8.5 due to current limit: Active-LoadBalancing
2025-11-08T07:43:46.347Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.0% (8.4 A)
2025-11-08T07:43:57.476Z:INFO:taskMain.c:5996:Socket #1: Active current 8.5->7.5 due to current limit: Active-LoadBalancing
2025-11-08T07:43:58.464Z:INFO:taskMain.c:6510:Socket #1: PWM DC 12.4% (7.4 A)
2025-11-08T07:44:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:44:09.476Z:INFO:taskMain.c:5996:Socket #1: Active current 7.5->6.9 due to current limit: Active-LoadBalancing
2025-11-08T07:44:09.574Z:INFO:taskMain.c:6510:Socket #1: PWM DC 11.4% (6.8 A)
2025-11-08T07:44:21.472Z:INFO:taskMain.c:5996:Socket #1: Active current 6.9->8.9 due to current limit: Active-LoadBalancing
2025-11-08T07:44:21.695Z:INFO:taskMain.c:6510:Socket #1: PWM DC 14.8% (8.9 A)
2025-11-08T07:44:31.417Z:INFO:active_lb.c:308:SMt:(4.0 1.0 1.0)A Free:(12.0 15.0 15.0)A ALB:(8.9 15.0 14.9)A
2025-11-08T07:44:33.472Z:INFO:taskMain.c:5996:Socket #1: Active current 8.9->10.2 due to current limit: Active-LoadBalancing
2025-11-08T07:44:33.812Z:INFO:taskMain.c:6510:Socket #1: PWM DC 16.9% (10.1 A)
2025-11-08T07:44:45.472Z:INFO:taskMain.c:5996:Socket #1: Active current 10.2->10.9 due to current limit: Active-LoadBalancing
2025-11-08T07:44:45.929Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.1% (10.9 A)
2025-11-08T07:44:57.468Z:INFO:taskMain.c:5996:Socket #1: Active current 10.9->11.3 due to current limit: Active-LoadBalancing
2025-11-08T07:44:58.050Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.8% (11.3 A)
2025-11-08T07:45:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T07:45:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:45:09.468Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.6 due to current limit: Active-LoadBalancing
2025-11-08T07:45:21.468Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-08T07:45:45.464Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.9 due to current limit: Active-LoadBalancing
2025-11-08T07:45:57.464Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.5 due to current limit: Active-LoadBalancing
2025-11-08T07:45:57.632Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.2% (11.5 A)
2025-11-08T07:46:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:46:09.460Z:INFO:taskMain.c:5996:Socket #1: Active current 11.5->11.3 due to current limit: Active-LoadBalancing
2025-11-08T07:46:21.460Z:INFO:taskMain.c:5996:Socket #1: Active current 11.3->11.6 due to current limit: Active-LoadBalancing
2025-11-08T07:46:33.460Z:INFO:taskMain.c:5996:Socket #1: Active current 11.6->11.8 due to current limit: Active-LoadBalancing
2025-11-08T07:46:57.457Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->11.9 due to current limit: Active-LoadBalancing
2025-11-08T07:47:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:47:09.250Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_ON
2025-11-08T07:47:09.257Z:INFO:taskMaster.c:6638:Start logging meter values @30s.
2025-11-08T07:47:09.269Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=234.7V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T07:47:09.281Z:USER:taskMaster.c:6720:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA
2025-11-08T07:47:09.292Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_ON
2025-11-08T07:47:09.300Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_C2
2025-11-08T07:47:09.308Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-08T07:47:09.335Z:INFO:taskMain.c:6494:Socket #1: CPhigh 6.3 V
2025-11-08T07:47:10.277Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_POWER_ON, CP: 6.3/-11.4, tag: 04BB29EAFD0F94
2025-11-08T07:47:21.453Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->12.2 due to current limit: Active-LoadBalancing
2025-11-08T07:47:33.453Z:INFO:taskMain.c:5996:Socket #1: Active current 12.2->11.9 due to current limit: Active-LoadBalancing
2025-11-08T07:47:33.464Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.2->19.8)
2025-11-08T07:47:39.296Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.8V L3N=233.6V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T07:47:39.308Z:USER:taskMaster.c:6720:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-11-08T07:47:45.453Z:INFO:taskMain.c:5996:Socket #1: Active current 11.9->12.1 due to current limit: Active-LoadBalancing
2025-11-08T07:47:57.449Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->12.3 due to current limit: Active-LoadBalancing
2025-11-08T07:48:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:48:09.257Z:INFO:taskMain.c:6562:Socket #1: reset HF switch count 1
2025-11-08T07:48:09.292Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=235.0V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T07:48:09.304Z:USER:taskMaster.c:6720:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-11-08T07:48:21.449Z:INFO:taskMain.c:5996:Socket #1: Active current 12.4->12.4 due to current limit: Active-LoadBalancing
2025-11-08T07:48:39.289Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.8V L3N=233.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T07:48:39.304Z:USER:taskMaster.c:6720:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-11-08T07:49:04.039Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:49:09.289Z:USER:taskMaster.c:6684:Socket #1: L1N=233.7V L2N=234.9V L3N=233.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T07:49:09.300Z:USER:taskMaster.c:6720:Socket #1: I1=0.5A I2=0.5A I3=0.5A P=0.0kW Idc=0.7mA
2025-11-08T07:49:09.445Z:INFO:taskMain.c:5996:Socket #1: Active current 12.5->12.1 due to current limit: Active-LoadBalancing
2025-11-08T07:49:09.457Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.7->20.1)
2025-11-08T07:49:09.468Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.1% (12.1 A)
2025-11-08T07:49:21.441Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->11.8 due to current limit: Active-LoadBalancing
2025-11-08T07:49:21.453Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.1->19.7)
2025-11-08T07:49:33.441Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->15.1 due to current limit: Active-LoadBalancing
2025-11-08T07:49:33.679Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.1% (15.1 A)
2025-11-08T07:49:39.285Z:USER:taskMaster.c:6684:Socket #1: L1N=232.4V L2N=235.2V L3N=231.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T07:49:39.296Z:USER:taskMaster.c:6720:Socket #1: I1=8.9A I2=0.5A I3=9.1A P=4.1kW Idc=0.7mA
2025-11-08T07:49:45.441Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->13.8 due to current limit: Active-LoadBalancing
2025-11-08T07:49:45.453Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->23.0)
2025-11-08T07:49:45.800Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-08T07:49:57.437Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->13.4 due to current limit: Active-LoadBalancing
2025-11-08T07:49:57.449Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.0->22.3)
2025-11-08T07:49:57.917Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.3% (13.4 A)
2025-11-08T07:50:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:50:09.281Z:USER:taskMaster.c:6684:Socket #1: L1N=232.9V L2N=235.5V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T07:50:09.292Z:USER:taskMaster.c:6720:Socket #1: I1=9.7A I2=0.5A I3=9.9A P=4.5kW Idc=0.7mA
2025-11-08T07:50:09.437Z:INFO:taskMain.c:5996:Socket #1: Active current 13.4->12.7 due to current limit: Active-LoadBalancing
2025-11-08T07:50:09.449Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (22.3->21.2)
2025-11-08T07:50:10.035Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.2% (12.7 A)
2025-11-08T07:50:21.437Z:INFO:taskMain.c:5996:Socket #1: Active current 12.7->12.3 due to current limit: Active-LoadBalancing
2025-11-08T07:50:21.449Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (21.2->20.5)
2025-11-08T07:50:22.156Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.5% (12.3 A)
2025-11-08T07:50:33.433Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->12.0 due to current limit: Active-LoadBalancing
2025-11-08T07:50:33.445Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.5->20.0)
2025-11-08T07:50:39.277Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=235.3V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T07:50:39.289Z:USER:taskMaster.c:6720:Socket #1: I1=9.2A I2=0.5A I3=9.3A P=4.3kW Idc=0.7mA
2025-11-08T07:50:45.433Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (20.0->19.9)
2025-11-08T07:50:57.433Z:INFO:taskMain.c:5996:Socket #1: Active current 12.0->12.2 due to current limit: Active-LoadBalancing
2025-11-08T07:51:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:51:09.273Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=234.7V L3N=232.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T07:51:09.285Z:USER:taskMaster.c:6720:Socket #1: I1=8.4A I2=0.5A I3=8.6A P=3.9kW Idc=0.7mA
2025-11-08T07:51:21.429Z:INFO:taskMain.c:5996:Socket #1: Active current 12.3->13.3 due to current limit: Active-LoadBalancing
2025-11-08T07:51:21.738Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.1% (13.3 A)
2025-11-08T07:51:33.429Z:INFO:taskMain.c:5996:Socket #1: Active current 13.3->13.8 due to current limit: Active-LoadBalancing
2025-11-08T07:51:33.859Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.9% (13.7 A)
2025-11-08T07:51:39.273Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=234.9V L3N=232.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T07:51:39.285Z:USER:taskMaster.c:6720:Socket #1: I1=7.5A I2=0.5A I3=7.5A P=3.6kW Idc=0.7mA
2025-11-08T07:51:45.425Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->14.3 due to current limit: Active-LoadBalancing
2025-11-08T07:51:45.976Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.8% (14.3 A)
2025-11-08T07:51:57.425Z:INFO:taskMain.c:5996:Socket #1: Active current 14.3->14.6 due to current limit: Active-LoadBalancing
2025-11-08T07:52:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:52:09.269Z:USER:taskMaster.c:6684:Socket #1: L1N=233.1V L2N=235.1V L3N=232.4V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T07:52:09.281Z:USER:taskMaster.c:6720:Socket #1: I1=6.7A I2=0.5A I3=6.7A P=3.0kW Idc=0.7mA
2025-11-08T07:52:09.292Z:INFO:taskMaster.c:6626:Stop logging meter values @30s.
2025-11-08T07:52:21.421Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->14.5 due to current limit: Active-LoadBalancing
2025-11-08T07:52:21.437Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.3->24.0)
2025-11-08T07:52:27.902Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->15.0 due to current limit: Active-LoadBalancing
2025-11-08T07:52:28.390Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.9% (14.9 A)
2025-11-08T07:52:33.421Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.9 due to current limit: ChargingProfile
2025-11-08T07:52:33.433Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-08T07:52:33.464Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-08T07:53:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:53:09.417Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.6 due to current limit: Active-LoadBalancing
2025-11-08T07:53:09.429Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->26.0)
2025-11-08T07:53:09.460Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-08T07:53:21.417Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.4 due to current limit: Active-LoadBalancing
2025-11-08T07:53:21.429Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.0->25.6)
2025-11-08T07:53:33.414Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.2 due to current limit: Active-LoadBalancing
2025-11-08T07:53:33.429Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.6->25.4)
2025-11-08T07:53:45.414Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.1 due to current limit: Active-LoadBalancing
2025-11-08T07:53:45.425Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-08T07:53:57.414Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.3 due to current limit: Active-LoadBalancing
2025-11-08T07:54:04.007Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:54:09.410Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.6 due to current limit: Active-LoadBalancing
2025-11-08T07:54:10.382Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.0% (15.6 A)
2025-11-08T07:54:21.410Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.0->26.0)
2025-11-08T07:54:31.351Z:INFO:active_lb.c:308:SMt:(12.0 2.0 2.0)A Free:(4.0 14.0 14.0)A ALB:(15.6 14.5 14.5)A
2025-11-08T07:54:33.410Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.5 due to current limit: Active-LoadBalancing
2025-11-08T07:54:33.421Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.0->25.8)
2025-11-08T07:54:43.050Z:USER:taskMaster.c:6582:Temperature: 23.1 C
2025-11-08T07:54:45.406Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.8 due to current limit: Active-LoadBalancing
2025-11-08T07:54:57.449Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-08T07:55:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:55:09.406Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->26.4)
2025-11-08T07:55:09.449Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-08T07:55:21.402Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.7 due to current limit: Active-LoadBalancing
2025-11-08T07:55:21.417Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.4->26.1)
2025-11-08T07:55:33.402Z:INFO:taskMain.c:5996:Socket #1: Active current 15.7->15.8 due to current limit: Active-LoadBalancing
2025-11-08T07:55:45.402Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.2->26.1)
2025-11-08T07:55:57.398Z:INFO:taskMain.c:5996:Socket #1: Active current 15.7->15.5 due to current limit: Active-LoadBalancing
2025-11-08T07:55:57.414Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.1->25.8)
2025-11-08T07:56:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:56:09.398Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.2 due to current limit: Active-LoadBalancing
2025-11-08T07:56:09.410Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.8->25.2)
2025-11-08T07:56:09.539Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.2% (15.1 A)
2025-11-08T07:56:21.398Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.6 due to current limit: Active-LoadBalancing
2025-11-08T07:56:21.656Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.9% (15.5 A)
2025-11-08T07:56:33.394Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.8 due to current limit: Active-LoadBalancing
2025-11-08T07:56:45.394Z:INFO:taskMain.c:5996:Socket #1: Active current 15.8->15.4 due to current limit: Active-LoadBalancing
2025-11-08T07:56:45.406Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.3->25.6)
2025-11-08T07:56:45.894Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.6% (15.4 A)
2025-11-08T07:56:57.394Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.5 due to current limit: Active-LoadBalancing
2025-11-08T07:57:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:57:09.390Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.6 due to current limit: Active-LoadBalancing
2025-11-08T07:57:21.390Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.5 due to current limit: Active-LoadBalancing
2025-11-08T07:57:21.402Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.0->25.8)
2025-11-08T07:57:33.390Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.8->25.7)
2025-11-08T07:57:45.390Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.3 due to current limit: Active-LoadBalancing
2025-11-08T07:57:45.402Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->25.4)
2025-11-08T07:57:57.386Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->12.6 due to current limit: Active-LoadBalancing
2025-11-08T07:57:57.398Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->21.0)
2025-11-08T07:57:57.597Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.0% (12.6 A)
2025-11-08T07:58:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:58:09.386Z:INFO:taskMain.c:5996:Socket #1: Active current 12.6->13.8 due to current limit: Active-LoadBalancing
2025-11-08T07:58:09.714Z:INFO:taskMain.c:6510:Socket #1: PWM DC 23.0% (13.8 A)
2025-11-08T07:58:21.386Z:INFO:taskMain.c:5996:Socket #1: Active current 13.8->11.8 due to current limit: Active-LoadBalancing
2025-11-08T07:58:21.398Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (23.0->19.6)
2025-11-08T07:58:21.835Z:INFO:taskMain.c:6510:Socket #1: PWM DC 19.6% (11.8 A)
2025-11-08T07:58:33.382Z:INFO:taskMain.c:5996:Socket #1: Active current 11.8->10.8 due to current limit: Active-LoadBalancing
2025-11-08T07:58:33.394Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (19.6->18.0)
2025-11-08T07:58:33.953Z:INFO:taskMain.c:6510:Socket #1: PWM DC 18.0% (10.8 A)
2025-11-08T07:58:40.312Z:INFO:taskMain.c:5996:Socket #1: Active current 10.8->14.5 due to current limit: Active-LoadBalancing
2025-11-08T07:58:41.023Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-08T07:58:45.382Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->15.9 due to current limit: ChargingProfile
2025-11-08T07:58:45.425Z:INFO:taskMaster.c:4979:Socket #1: state led : CHARGING_POWER_ON
2025-11-08T07:58:46.070Z:INFO:taskMain.c:6510:Socket #1: PWM DC 26.5% (15.9 A)
2025-11-08T07:59:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T07:59:21.378Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.5->26.4)
2025-11-08T07:59:21.421Z:INFO:taskMaster.c:4979:Socket #1: state led : LOADBALANCING_LIMITED
2025-11-08T07:59:33.378Z:INFO:taskMain.c:5996:Socket #1: Active current 15.9->15.7 due to current limit: Active-LoadBalancing
2025-11-08T07:59:33.390Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.4->26.1)
2025-11-08T07:59:45.375Z:INFO:taskMain.c:5996:Socket #1: Active current 15.7->15.6 due to current limit: Active-LoadBalancing
2025-11-08T07:59:45.390Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.1->25.9)
2025-11-08T07:59:57.375Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.1 due to current limit: Active-LoadBalancing
2025-11-08T07:59:57.386Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.9->25.1)
2025-11-08T07:59:57.773Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.1% (15.1 A)
2025-11-08T08:00:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T08:00:04.019Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T08:00:09.375Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-08T08:00:09.386Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.9)
2025-11-08T08:00:21.371Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-08T08:00:22.011Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.5% (15.3 A)
2025-11-08T08:00:33.371Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.2 due to current limit: Active-LoadBalancing
2025-11-08T08:00:33.382Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.5->25.3)
2025-11-08T08:00:45.371Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.1)
2025-11-08T08:00:57.367Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.1 due to current limit: Active-LoadBalancing
2025-11-08T08:00:57.382Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->25.0)
2025-11-08T08:01:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T08:01:07.914Z:INFO:db_chargingprofi:26:ChargingProfile (id = -19930828):
2025-11-08T08:01:07.925Z:INFO:db_chargingprofi:26: socket 0
2025-11-08T08:01:07.929Z:INFO:db_chargingprofi:27: primary Not specified
2025-11-08T08:01:07.941Z:INFO:db_chargingprofi:27: stackLevel 0
2025-11-08T08:01:07.949Z:INFO:db_chargingprofi:27: purposeType ExternalConstraints
2025-11-08T08:01:07.957Z:INFO:db_chargingprofi:27: transactionId 18446744073709551615 (not specified)
2025-11-08T08:01:07.968Z:INFO:db_chargingprofi:27: kindType Relative
2025-11-08T08:01:07.976Z:INFO:db_chargingprofi:27: recurrencyType Not specified
2025-11-08T08:01:07.984Z:INFO:db_chargingprofi:27: hasTariffs FALSE
2025-11-08T08:01:07.992Z:INFO:db_chargingprofi:28: validFrom NULL
2025-11-08T08:01:08.000Z:INFO:db_chargingprofi:28: validTo NULL
2025-11-08T08:01:08.007Z:INFO:db_chargingprofi:28: useLocalTime TRUE
2025-11-08T08:01:08.015Z:INFO:db_chargingprofi:28: useRandomDelay FALSE
2025-11-08T08:01:08.023Z:INFO:db_chargingprofi:28: ChargingSchedule
2025-11-08T08:01:08.031Z:INFO:db_chargingprofi:28: duration 4294967295 (not specified)
2025-11-08T08:01:08.042Z:INFO:db_chargingprofi:28: startSchedule NULL
2025-11-08T08:01:08.050Z:INFO:db_chargingprofi:28: chargingRateUnit Amperes
2025-11-08T08:01:08.058Z:INFO:db_chargingprofi:28: minChargingRate -1.00 (not specified)
2025-11-08T08:01:08.070Z:INFO:db_chargingprofi:29: schedulePeriods 1
2025-11-08T08:01:08.078Z:INFO:db_chargingprofi:29: SchedulePeriod:
2025-11-08T08:01:08.085Z:INFO:db_chargingprofi:29: startPeriod 0
2025-11-08T08:01:08.093Z:INFO:db_chargingprofi:29: limit 15.90
2025-11-08T08:01:08.101Z:INFO:db_chargingprofi:29: numberPhases 3
2025-11-08T08:01:21.367Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->25.1)
2025-11-08T08:01:33.363Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.2 due to current limit: Active-LoadBalancing
2025-11-08T08:01:45.363Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.1 due to current limit: Active-LoadBalancing
2025-11-08T08:01:45.375Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->25.1)
2025-11-08T08:02:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T08:02:09.359Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T08:02:09.375Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.8)
2025-11-08T08:02:33.359Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-08T08:02:45.355Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.0 due to current limit: Active-LoadBalancing
2025-11-08T08:02:45.371Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->24.9)
2025-11-08T08:02:57.355Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.3 due to current limit: Active-LoadBalancing
2025-11-08T08:02:57.535Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.5% (15.3 A)
2025-11-08T08:03:04.000Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T08:03:09.355Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.6 due to current limit: Active-LoadBalancing
2025-11-08T08:03:21.351Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.2 due to current limit: Active-LoadBalancing
2025-11-08T08:03:21.367Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.9->25.3)
2025-11-08T08:03:21.773Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.3% (15.2 A)
2025-11-08T08:03:33.351Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.2)
2025-11-08T08:03:57.347Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-08T08:03:57.363Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-08T08:04:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T08:04:09.347Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.1 due to current limit: Active-LoadBalancing
2025-11-08T08:04:21.347Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.0 due to current limit: Active-LoadBalancing
2025-11-08T08:04:21.359Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.2->24.9)
2025-11-08T08:04:31.289Z:INFO:active_lb.c:308:SMt:(1.0 2.0 10.0)A Free:(15.0 14.0 6.0)A ALB:(15.5 14.5 15.0)A
2025-11-08T08:04:33.343Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.9)
2025-11-08T08:04:45.343Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->14.8 due to current limit: Active-LoadBalancing
2025-11-08T08:04:45.355Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.9->24.7)
2025-11-08T08:04:57.343Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.7 due to current limit: Active-LoadBalancing
2025-11-08T08:04:57.355Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.4)
2025-11-08T08:05:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T08:05:09.339Z:INFO:taskMain.c:5996:Socket #1: Active current 14.7->15.2 due to current limit: Active-LoadBalancing
2025-11-08T08:05:09.839Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.4% (15.2 A)
2025-11-08T08:05:21.339Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.1 due to current limit: Active-LoadBalancing
2025-11-08T08:05:21.351Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.1)
2025-11-08T08:05:33.339Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.9 due to current limit: Active-LoadBalancing
2025-11-08T08:05:33.351Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.7)
2025-11-08T08:05:45.335Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.7->24.6)
2025-11-08T08:05:57.335Z:INFO:taskMain.c:5996:Socket #1: Active current 14.8->14.6 due to current limit: Active-LoadBalancing
2025-11-08T08:05:57.347Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.6->24.4)
2025-11-08T08:06:04.031Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T08:06:09.335Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.4->24.3)
2025-11-08T08:06:21.335Z:INFO:taskMain.c:5996:Socket #1: Active current 14.6->15.1 due to current limit: Active-LoadBalancing
2025-11-08T08:06:21.542Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.2% (15.1 A)
2025-11-08T08:06:33.332Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.3 due to current limit: Active-LoadBalancing
2025-11-08T08:06:45.332Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->14.9 due to current limit: Active-LoadBalancing
2025-11-08T08:06:45.343Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->24.9)
2025-11-08T08:06:57.332Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.4 due to current limit: Active-LoadBalancing
2025-11-08T08:06:57.898Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.6% (15.4 A)
2025-11-08T08:07:04.023Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T08:07:09.171Z:USER:taskMaster.c:6684:Socket #1: L1N=236.1V L2N=237.7V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T08:07:09.183Z:USER:taskMaster.c:6720:Socket #1: I1=0.5A I2=0.5A I3=8.5A P=1.9kW Idc=0.7mA
2025-11-08T08:07:33.328Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->25.7)
2025-11-08T08:07:57.324Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->25.7)
2025-11-08T08:08:04.015Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T08:08:09.324Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->14.9 due to current limit: Active-LoadBalancing
2025-11-08T08:08:09.335Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->24.8)
2025-11-08T08:08:09.601Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.8% (14.9 A)
2025-11-08T08:08:21.320Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.0 due to current limit: Active-LoadBalancing
2025-11-08T08:08:33.320Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-08T08:08:45.320Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.0 due to current limit: Active-LoadBalancing
2025-11-08T08:08:45.332Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.3->25.0)
2025-11-08T08:08:57.316Z:INFO:taskMain.c:5996:Socket #1: Active current 15.0->15.2 due to current limit: Active-LoadBalancing
2025-11-08T08:09:04.011Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T08:09:09.316Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.3 due to current limit: Active-LoadBalancing
2025-11-08T08:09:21.316Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->25.3)
2025-11-08T08:09:33.312Z:INFO:taskMain.c:5996:Socket #1: Active current 15.2->15.4 due to current limit: Active-LoadBalancing
2025-11-08T08:09:43.457Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-08T08:09:57.312Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.1 due to current limit: Active-LoadBalancing
2025-11-08T08:09:57.324Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->25.1)
2025-11-08T08:09:57.660Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.1% (15.1 A)
2025-11-08T08:10:04.003Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T08:10:09.308Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->15.4 due to current limit: Active-LoadBalancing
2025-11-08T08:10:21.308Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.5 due to current limit: Active-LoadBalancing
2025-11-08T08:10:45.304Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.9->25.8)
2025-11-08T08:11:04.046Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T08:11:09.304Z:INFO:taskMain.c:5996:Socket #1: Active current 15.6->15.7 due to current limit: Active-LoadBalancing
2025-11-08T08:11:21.300Z:INFO:taskMain.c:5996:Socket #1: Active current 15.7->15.5 due to current limit: Active-LoadBalancing
2025-11-08T08:11:21.316Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (26.1->25.8)
2025-11-08T08:11:33.300Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.4 due to current limit: Active-LoadBalancing
2025-11-08T08:11:33.312Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.8->25.6)
2025-11-08T08:12:04.042Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T08:12:09.296Z:INFO:taskMain.c:5996:Socket #1: Active current 15.4->15.3 due to current limit: Active-LoadBalancing
2025-11-08T08:12:09.308Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->25.4)
2025-11-08T08:12:21.296Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->15.5 due to current limit: Active-LoadBalancing
2025-11-08T08:12:33.292Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->15.3 due to current limit: Active-LoadBalancing
2025-11-08T08:12:33.308Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.7->25.4)
2025-11-08T08:12:45.292Z:INFO:taskMain.c:5996:Socket #1: Active current 15.3->14.9 due to current limit: Active-LoadBalancing
2025-11-08T08:12:45.304Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.4->24.8)
2025-11-08T08:12:45.320Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.8% (14.9 A)
2025-11-08T08:12:57.292Z:INFO:taskMain.c:5996:Socket #1: Active current 14.9->15.1 due to current limit: Active-LoadBalancing
2025-11-08T08:13:02.292Z:INFO:taskMain.c:5996:Socket #1: Active current 15.1->14.5 due to current limit: Active-LoadBalancing
2025-11-08T08:13:02.304Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (25.1->24.1)
2025-11-08T08:13:02.480Z:INFO:taskMain.c:6510:Socket #1: PWM DC 24.1% (14.5 A)
2025-11-08T08:13:04.035Z:INFO:taskMaster.c:5917:Socket #1: next sample interval metervalue in 60 seconds
2025-11-08T08:13:09.289Z:INFO:taskMain.c:5996:Socket #1: Active current 14.5->12.1 due to current limit: Active-LoadBalancing
2025-11-08T08:13:09.304Z:INFO:taskMain.c:5607:Socket #1: overcurrent detection limited for max. 30 seconds (24.1->20.0)
2025-11-08T08:13:09.550Z:INFO:taskMain.c:6510:Socket #1: PWM DC 20.0% (12.0 A)
2025-11-08T08:13:21.289Z:INFO:taskMain.c:5996:Socket #1: Active current 12.1->13.0 due to current limit: Active-LoadBalancing
2025-11-08T08:13:21.667Z:INFO:taskMain.c:6510:Socket #1: PWM DC 21.7% (13.0 A)
2025-11-08T08:13:33.289Z:INFO:taskMain.c:5996:Socket #1: Active current 13.0->13.6 due to current limit: Active-LoadBalancing
2025-11-08T08:13:33.789Z:INFO:taskMain.c:6510:Socket #1: PWM DC 22.6% (13.6 A)
2025-11-08T08:13:38.289Z:INFO:taskMain.c:5996:Socket #1: Active current 13.6->15.5 due to current limit: Active-LoadBalancing
2025-11-08T08:13:38.835Z:INFO:taskMain.c:6510:Socket #1: PWM DC 25.7% (15.4 A)
2025-11-08T08:13:44.531Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_POWER_OFF
2025-11-08T08:13:44.539Z:INFO:taskMaster.c:4965:Socket #1: state power : POWER_OFF
2025-11-08T08:13:44.550Z:WARNING:taskMain.c:4758:Socket #1: EV disconnected while charging (12.3V)
2025-11-08T08:13:44.558Z:INFO:taskMain.c:5996:Socket #1: Active current 15.5->0.0 due to current limit: Cable
2025-11-08T08:13:44.570Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_B2
2025-11-08T08:13:44.578Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_EVCONNECT
2025-11-08T08:13:44.589Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_WAIT_FOR_EV_RECONNECT
2025-11-08T08:13:44.601Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_A
2025-11-08T08:13:44.632Z:INFO:taskMaster.c:4957:Socket #1: state main : CHARGING_TERMINATING
2025-11-08T08:13:44.640Z:INFO:taskMaster.c:4972:Socket #1: state Mode-3: STATE_E
2025-11-08T08:13:44.648Z:INFO:taskMaster.c:4979:Socket #1: state led : WAIT_FOR_VEHICLE
2025-11-08T08:13:44.898Z:INFO:taskMain.c:6494:Socket #1: CPhigh 0.0 V
2025-11-08T08:13:44.906Z:INFO:taskMain.c:6499:Socket #1: CPlow 0.0 V
2025-11-08T08:13:44.914Z:INFO:taskMain.c:6504:Socket #1: PP 34464 Ohm (0 A)
2025-11-08T08:13:45.656Z:INFO:taskMain.c:1417:Socket #1: main state: CHARGING_TERMINATING, CP: 0.0/0.0, tag: 04BB29EAFD0F94
2025-11-08T08:13:48.679Z:INFO:taskMaster.c:4957:Socket #1: state main : WAIT_FOR_STOP_METERVALUE
2025-11-08T08:13:49.546Z:INFO:taskMain.c:938:Socket #1: charging session status set inactive
2025-11-08T08:13:49.554Z:USER:board_ng9xx.c:5068:Socket #1: unlock socket motor
2025-11-08T08:13:49.582Z:INFO:taskMaster.c:4957:Socket #1: state main : WAIT_FOR_DISCONNECT
2025-11-08T08:13:50.140Z:INFO:db_transaction.c:16:Added TransactionStop for socket 1 at 0x0002ab98 (ts: 2025-11-08 08:13:49)
2025-11-08T08:13:50.152Z:INFO:db_transaction.c:16:Updated TransactionStart for socket 1 at 0x0001a9f1 (ts: 2025-11-07 15:51:03)
2025-11-08T08:13:50.214Z:INFO:taskMaster.c:4979:Socket #1: state led : AVAILABLE
2025-11-08T08:13:50.273Z:INFO:taskMaster.c:4957:Socket #1: state main : AVAILABLE
2025-11-08T08:13:50.285Z:INFO:taskMain.c:6440:Socket #1: active tag cleared
2025-11-08T08:13:51.195Z:INFO:taskMain.c:1419:Socket #1: main state: AVAILABLE, CP: 0.0/0.0, no tag
2025-11-08T08:14:31.226Z:INFO:active_lb.c:308:SMt:(1.0 2.0 1.0)A Free:(15.0 14.0 15.0)A ALB:(14.6 14.1 14.6)A
2025-11-08T08:15:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T08:22:09.078Z:USER:taskMaster.c:6684:Socket #1: L1N=233.0V L2N=233.7V L3N=232.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T08:24:31.164Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-08T08:24:43.812Z:USER:taskMaster.c:6582:Temperature: 24.4 C
2025-11-08T08:30:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T08:34:31.097Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-08T08:37:08.984Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.3V L3N=233.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T08:39:44.214Z:USER:taskMaster.c:6582:Temperature: 23.8 C
2025-11-08T08:44:31.035Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(16.2 15.0 15.0)A
2025-11-08T08:45:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T08:52:08.886Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.1V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T08:54:30.972Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.2 15.0 15.0)A
2025-11-08T08:54:44.570Z:USER:taskMaster.c:6582:Temperature: 23.8 C
2025-11-08T09:00:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T09:04:30.910Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-08T09:07:08.792Z:USER:taskMaster.c:6684:Socket #1: L1N=232.6V L2N=232.8V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T09:09:44.925Z:USER:taskMaster.c:6582:Temperature: 23.9 C
2025-11-08T09:14:30.843Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(16.7 15.0 15.0)A
2025-11-08T09:15:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T09:22:08.699Z:USER:taskMaster.c:6684:Socket #1: L1N=234.1V L2N=234.7V L3N=234.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T09:24:30.781Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-08T09:24:45.332Z:USER:taskMaster.c:6582:Temperature: 23.9 C
2025-11-08T09:30:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T09:34:17.476Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-08T09:34:17.746Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-08T09:34:22.320Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-08T09:34:22.328Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-08T09:34:30.718Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-08T09:34:30.730Z:INFO:comFaults.c:482:Reset fault status
2025-11-08T09:37:08.601Z:USER:taskMaster.c:6684:Socket #1: L1N=235.8V L2N=235.6V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T09:39:45.687Z:USER:taskMaster.c:6582:Temperature: 24.0 C
2025-11-08T09:44:30.656Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(15.8 15.0 15.0)A
2025-11-08T09:45:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T09:52:08.507Z:USER:taskMaster.c:6684:Socket #1: L1N=235.9V L2N=236.2V L3N=234.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T09:54:30.593Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-08T09:54:46.089Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-08T10:00:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T10:04:30.527Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-08T10:07:08.410Z:USER:taskMaster.c:6684:Socket #1: L1N=236.9V L2N=236.8V L3N=236.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T10:09:46.496Z:USER:taskMaster.c:6582:Temperature: 24.2 C
2025-11-08T10:14:30.464Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(15.0 17.0 15.0)A ALB:(14.0 16.8 15.0)A
2025-11-08T10:15:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T10:22:08.316Z:USER:taskMaster.c:6684:Socket #1: L1N=235.7V L2N=235.9V L3N=234.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T10:24:30.402Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-08T10:24:46.851Z:USER:taskMaster.c:6582:Temperature: 24.1 C
2025-11-08T10:30:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T10:34:30.339Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-08T10:37:08.222Z:USER:taskMaster.c:6684:Socket #1: L1N=237.4V L2N=238.5V L3N=237.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T10:39:47.253Z:USER:taskMaster.c:6582:Temperature: 24.5 C
2025-11-08T10:44:30.273Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(15.0 17.0 15.0)A ALB:(15.1 17.0 15.0)A
2025-11-08T10:45:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T10:52:08.125Z:USER:taskMaster.c:6684:Socket #1: L1N=235.0V L2N=235.6V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T10:54:30.210Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 1.0)A Free:(17.0 18.0 15.0)A ALB:(16.7 18.1 15.0)A
2025-11-08T10:54:47.609Z:USER:taskMaster.c:6582:Temperature: 24.4 C
2025-11-08T11:00:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T11:04:30.148Z:INFO:active_lb.c:308:SMt:(-1.0 -3.0 1.0)A Free:(17.0 19.0 15.0)A ALB:(17.1 19.0 15.0)A
2025-11-08T11:07:08.031Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=236.8V L3N=236.9V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T11:09:48.015Z:USER:taskMaster.c:6582:Temperature: 24.8 C
2025-11-08T11:14:30.085Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 1.0)A Free:(17.0 18.0 15.0)A ALB:(17.0 18.0 15.0)A
2025-11-08T11:15:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T11:22:07.937Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=234.2V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T11:24:30.019Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-08T11:24:48.417Z:USER:taskMaster.c:6582:Temperature: 24.6 C
2025-11-08T11:30:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T11:34:21.558Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-08T11:34:21.566Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-08T11:34:29.957Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-08T11:37:07.839Z:USER:taskMaster.c:6684:Socket #1: L1N=234.6V L2N=235.2V L3N=234.5V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T11:39:48.824Z:USER:taskMaster.c:6582:Temperature: 25.2 C
2025-11-08T11:44:29.894Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(15.0 17.0 15.0)A ALB:(15.0 17.0 15.0)A
2025-11-08T11:45:00.039Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T11:52:07.746Z:USER:taskMaster.c:6684:Socket #1: L1N=234.8V L2N=234.7V L3N=235.2V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T11:54:29.832Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-08T11:54:49.230Z:USER:taskMaster.c:6582:Temperature: 25.9 C
2025-11-08T12:00:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T12:04:29.765Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(16.2 17.0 15.0)A
2025-11-08T12:07:07.652Z:USER:taskMaster.c:6684:Socket #1: L1N=235.8V L2N=235.2V L3N=235.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T12:09:49.535Z:USER:taskMaster.c:6582:Temperature: 26.2 C
2025-11-08T12:14:29.703Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.2 16.6 15.0)A
2025-11-08T12:15:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T12:22:07.554Z:USER:taskMaster.c:6684:Socket #1: L1N=233.6V L2N=233.9V L3N=233.7V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T12:24:29.640Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(16.8 17.1 15.0)A
2025-11-08T12:24:49.937Z:USER:taskMaster.c:6582:Temperature: 26.0 C
2025-11-08T12:30:00.003Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T12:34:29.578Z:INFO:active_lb.c:308:SMt:(-1.0 -2.0 1.0)A Free:(17.0 18.0 15.0)A ALB:(17.0 18.0 15.0)A
2025-11-08T12:37:07.460Z:USER:taskMaster.c:6684:Socket #1: L1N=233.8V L2N=233.5V L3N=233.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T12:39:50.343Z:USER:taskMaster.c:6582:Temperature: 26.2 C
2025-11-08T12:44:29.515Z:INFO:active_lb.c:308:SMt:(-2.0 -2.0 1.0)A Free:(18.0 18.0 15.0)A ALB:(17.0 17.7 15.0)A
2025-11-08T12:45:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T12:52:07.367Z:USER:taskMaster.c:6684:Socket #1: L1N=235.5V L2N=235.9V L3N=235.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T12:54:29.449Z:INFO:active_lb.c:308:SMt:(1.0 -1.0 1.0)A Free:(15.0 17.0 15.0)A ALB:(15.4 17.0 15.0)A
2025-11-08T12:54:50.699Z:USER:taskMaster.c:6582:Temperature: 26.8 C
2025-11-08T13:00:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T13:04:29.386Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.1 15.0)A
2025-11-08T13:07:07.324Z:USER:taskMaster.c:6684:Socket #1: L1N=236.3V L2N=236.3V L3N=237.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T13:09:51.105Z:USER:taskMaster.c:6582:Temperature: 27.0 C
2025-11-08T13:14:29.324Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-08T13:15:00.019Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T13:22:07.277Z:USER:taskMaster.c:6684:Socket #1: L1N=236.9V L2N=237.3V L3N=237.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T13:24:29.261Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(14.8 15.7 15.0)A
2025-11-08T13:24:51.460Z:USER:taskMaster.c:6582:Temperature: 27.4 C
2025-11-08T13:30:00.027Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T13:34:15.707Z:INFO:taskCANopen.c:1207:Persistent memory hash changed
2025-11-08T13:34:15.976Z:INFO:taskCANopen.c:1787:Updated object 0x21b6, 8 bytes
2025-11-08T13:34:20.796Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-08T13:34:20.808Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-08T13:34:29.199Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-08T13:37:07.179Z:USER:taskMaster.c:6684:Socket #1: L1N=234.7V L2N=235.3V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T13:39:51.863Z:USER:taskMaster.c:6582:Temperature: 27.4 C
2025-11-08T13:44:29.132Z:INFO:active_lb.c:308:SMt:(-1.0 -1.0 1.0)A Free:(17.0 17.0 15.0)A ALB:(17.0 17.0 15.0)A
2025-11-08T13:45:00.031Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T13:52:07.085Z:USER:taskMaster.c:6684:Socket #1: L1N=233.3V L2N=233.1V L3N=232.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T13:54:29.070Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-08T13:54:52.269Z:USER:taskMaster.c:6582:Temperature: 27.2 C
2025-11-08T14:00:00.035Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T14:04:29.007Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(16.9 15.1 15.0)A
2025-11-08T14:07:06.992Z:USER:taskMaster.c:6684:Socket #1: L1N=233.9V L2N=234.1V L3N=234.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T14:09:52.625Z:USER:taskMaster.c:6582:Temperature: 27.2 C
2025-11-08T14:14:28.945Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-08T14:15:00.042Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T14:22:06.894Z:USER:taskMaster.c:6684:Socket #1: L1N=232.8V L2N=233.5V L3N=233.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T14:24:28.882Z:INFO:active_lb.c:308:SMt:(-1.0 1.0 1.0)A Free:(17.0 15.0 15.0)A ALB:(17.0 15.0 15.0)A
2025-11-08T14:24:53.078Z:USER:taskMaster.c:6582:Temperature: 27.4 C
2025-11-08T14:30:00.046Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T14:34:28.816Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.1 15.0 15.0)A
2025-11-08T14:37:06.800Z:USER:taskMaster.c:6684:Socket #1: L1N=231.5V L2N=231.4V L3N=231.8V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T14:39:53.433Z:USER:taskMaster.c:6582:Temperature: 27.4 C
2025-11-08T14:44:28.753Z:INFO:active_lb.c:308:SMt:(1.0 1.0 1.0)A Free:(15.0 15.0 15.0)A ALB:(15.0 15.0 15.0)A
2025-11-08T14:45:00.000Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T14:52:06.707Z:USER:taskMaster.c:6684:Socket #1: L1N=232.1V L2N=230.7V L3N=232.3V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T14:54:28.691Z:INFO:active_lb.c:308:SMt:(1.0 4.0 2.0)A Free:(15.0 12.0 14.0)A ALB:(15.0 12.0 14.4)A
2025-11-08T14:54:53.839Z:USER:taskMaster.c:6582:Temperature: 27.2 C
2025-11-08T15:00:00.007Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T15:04:28.679Z:INFO:active_lb.c:308:SMt:(1.0 3.0 1.0)A Free:(15.0 13.0 15.0)A ALB:(15.0 13.0 10.9)A
2025-11-08T15:07:06.613Z:USER:taskMaster.c:6684:Socket #1: L1N=234.0V L2N=233.7V L3N=231.1V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T15:09:54.195Z:USER:taskMaster.c:6582:Temperature: 27.2 C
2025-11-08T15:14:28.613Z:INFO:active_lb.c:308:SMt:(2.0 3.0 10.0)A Free:(14.0 13.0 6.0)A ALB:(12.4 2.3 9.1)A
2025-11-08T15:15:00.011Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T15:22:06.515Z:USER:taskMaster.c:6684:Socket #1: L1N=233.3V L2N=232.1V L3N=232.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T15:24:28.550Z:INFO:active_lb.c:308:SMt:(1.0 4.0 10.0)A Free:(15.0 12.0 6.0)A ALB:(15.0 12.0 9.2)A
2025-11-08T15:24:54.550Z:USER:taskMaster.c:6582:Temperature: 27.2 C
2025-11-08T15:30:00.015Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T15:34:20.039Z:INFO:heap_trace.c:493:free: 69208/160768 (43.0%) min: 37040 (23.0%) alloc #: 198
2025-11-08T15:34:20.050Z:INFO:heap_trace.c:495:fragm: 40.8% 4K: 17.1% free blocks: # 17 largest: 40992
2025-11-08T15:34:28.488Z:INFO:active_lb.c:308:SMt:(2.0 3.0 11.0)A Free:(14.0 13.0 5.0)A ALB:(14.4 13.0 10.3)A
2025-11-08T15:34:39.171Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-08T15:34:39.839Z:SECURITY:httpd_login.c:155:WebClient connected (account: admin)
2025-11-08T15:34:39.941Z:WARNING:web_functionalit:48:Failed to parse property '2077_0'
2025-11-08T15:37:06.421Z:USER:taskMaster.c:6684:Socket #1: L1N=235.3V L2N=234.7V L3N=234.0V L1L2=n/a L2L3=n/a L3L1=n/a
2025-11-08T15:39:54.953Z:USER:taskMaster.c:6582:Temperature: 27.2 C
2025-11-08T15:44:28.425Z:INFO:active_lb.c:308:SMt:(1.0 3.0 11.0)A Free:(15.0 13.0 5.0)A ALB:(15.0 13.0 8.2)A
2025-11-08T15:45:00.023Z:INFO:taskMaster.c:5958:Socket #1: next clock aligned metervalue in 900 seconds
2025-11-08T15:48:45.417Z:SECURITY:taskWebClient.c:942:Removing client due to inactivity
2025-11-08T15:48:45.425Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-08T15:48:45.535Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-08T15:48:47.917Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-08T15:48:47.988Z:SECURITY:taskWebClient.c:446:Received unauthorized request, so removing client
2025-11-08T15:48:47.996Z:INFO:taskWebClient.c:166:Removing previously connected client
2025-11-08T15:48:48.046Z:INFO:taskWebServer.c:238:WebServer state BUSY -> AVAILABLE
2025-11-08T15:48:49.816Z:INFO:taskWebServer.c:238:WebServer state AVAILABLE -> BUSY
2025-11-08T15:48:50.457Z:SECURITY:httpd_login.c:155:WebClient RadomskiR connected (account: admin)